HPN-ICF-MPLSOAM-PS-MIB
File:
HPN-ICF-MPLSOAM-PS-MIB.mib (10546 bytes)
Imported modules
Imported symbols
Defined Types
HpnicfMplsPsEntry |
|
SEQUENCE |
|
|
|
|
hpnicfMplsPsIndex |
Integer32 |
|
|
hpnicfMplsPsGroupID |
Integer32 |
|
|
hpnicfMplsPsWorkLspName |
OCTET STRING |
|
|
hpnicfMplsPsProtectLspName |
OCTET STRING |
|
|
hpnicfMplsPsRevertiveMode |
Integer32 |
|
|
hpnicfMplsPsWTR |
Integer32 |
|
|
hpnicfMplsPsHoldOff |
Integer32 |
|
|
hpnicfMplsPsSwitchCondition |
Integer32 |
|
|
hpnicfMplsPsWorkLspDetectState |
Integer32 |
|
|
hpnicfMplsPsWorkLspUpDownState |
Integer32 |
|
|
hpnicfMplsPsProtLspDetectState |
Integer32 |
|
|
hpnicfMplsPsProtLspUpDownState |
Integer32 |
|
|
hpnicfMplsPsSwitchResult |
Integer32 |
|
|
hpnicfMplsPsRowStatus |
RowStatus |
|
Defined Values
hpnicfMplsOamPs |
1.3.6.1.4.1.11.2.14.11.15.2.80 |
This MIB contains objects to configure mpls
protect-switch module. |
MODULE-IDENTITY |
|
|
|
hpnicfMplsOamPsTrapOpen |
1.3.6.1.4.1.11.2.14.11.15.2.80.1.1 |
Whether mpls protect-switch trap is globally enabled.
false: disable;
true: enable |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
hpnicfMplsPsTable |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1 |
This table specifies per-protection-group MPLS PS
capability and associated information. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
HpnicfMplsPsEntry |
|
hpnicfMplsPsEntry |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1 |
An entry in this table is created by an LSR for every
protection group capable of supporting mpls ps. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HpnicfMplsPsEntry |
|
|
hpnicfMplsPsIndex |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.1 |
This is a unique index for an entry in the mplspsEntry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hpnicfMplsPsGroupID |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.2 |
This is a unique group id for an entry in the mplspsEntry.
One protect-switch group is composed of one working static-lsp
and one protection static-lsp. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hpnicfMplsPsWorkLspName |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.3 |
The name of the working static-lsp. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
hpnicfMplsPsProtectLspName |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.4 |
The name of the protection static-lsp. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
hpnicfMplsPsRevertiveMode |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.5 |
Revertive mode is a protection switching mode where revertive
action (switch back to the working LSP) is taken after the
working LSP is repaired. And switching does not occur in a
non-revertive mode.
1: revertive;
2: non-revertive; |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..2 |
|
hpnicfMplsPsWTR |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.6 |
Wait to Restore timer is only applicable for the revertive mode
and applies to a working LSP, it prevents reversion back to
select the working LSP until the Wait to Restore timer has
expired.
The default value is 12 minutes. step is 30s. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hpnicfMplsPsHoldOff |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.7 |
The time between declaration of signal degrade or signal fail,
and the initialization of the protection switching algorithm.
Step is 100ms, maximum is 10s. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
hpnicfMplsPsSwitchCondition |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.8 |
The current switch condition of the protection group.
1: clear, this command clears all of the externally
initiated switch commands listed below;
2: lockout of protection, fix the selector position on the
working LSP, Prevents the selector from switching to the
protection LSP when it is selecting the working LSP.
Switches the selector from the protection to the working LSP
when it is selecting the protection LSP;
3: forced protection, switches the selector from the working LSP
to the protection LSP (unless a higher priority switch
request (i.e., LoP) is in effect);
4: signal fail, for 1:1, Signal Fail (SF) is declared when the
source of the protection domain enters the Defect State by
receiving a BDI packet (from the return LSP or out of band).
5: manual switch for working-lsp, switches the selector from the
working LSP to the protection LSP (unless an equal or higher
priority switch request (i.e., LoP, FS, SF or MS) is in
effect);
6: manual switch for protection-lsp, switches the selector from
the protection LSP to the working LSP (unless an equal or
higher priority switch request (i.e., LoP, FS, SF or MS) is
in effect).
7: WTR-timer, a configurable timer which is used to delay before
reversion;
8: HoldOff-timer, the time between declaration of signal degrade
or signal fail, and the initialization of the protection
switching algorithm;
9: Others;
The pripority of the commands are:
clear > lockout of protection > force switch > manual switch for working
lsp = manual switch for protection lsp |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..9 |
|
hpnicfMplsPsWorkLspDetectState |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.9 |
The state of working static-lsp state in one protection group,
whether it is in defect:
1: it is out of defect;
2: it enters defect. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..2 |
|
hpnicfMplsPsWorkLspUpDownState |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.10 |
The state of working static-lsp state in one protection group,
whether it is up or down:
1: it is in up state;
2: it is in down state. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..2 |
|
hpnicfMplsPsProtLspDetectState |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.11 |
The state of protection static-lsp state in one protection group,
whether it is in detection:
1: it is out of defect;
2: it enters defect. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..2 |
|
hpnicfMplsPsProtLspUpDownState |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.12 |
The state of protection static-lsp state in one protection group,
whether it is up or down:
1: it is in up state;
2: it is in down state. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..2 |
|
hpnicfMplsPsSwitchResult |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.13 |
Which tunnel is used to transfer the data stream.
1: working static-lsp;
2: protection static-lsp. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..2 |
|
hpnicfMplsPsRowStatus |
1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.14 |
This object is responsible for managing the creation,
deletion and modification of rows, which support active
status and CreatAndGo, destroy operation.
To create a new row, hpnicfMplsPsGroupID, hpnicfMplsPsWorkLspName,
hpnicfMplsPsProtectLspName, hpnicfMplsPsRevertiveMode, hpnicfMplsPsWTR
and hpnicfMplsPsHoldOff must be specified. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
hpnicfMplsPsSwitchPtoW |
1.3.6.1.4.1.11.2.14.11.15.2.80.3.1 |
This notification is generated when switching from
protection-lsp to working-lsp occured. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
hpnicfMplsPsSwitchWtoP |
1.3.6.1.4.1.11.2.14.11.15.2.80.3.2 |
This notification is generated when switching from woking-lsp
to protection-lsp occured. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|