HPN-ICF-MPLSOAM-PS-MIB

File: HPN-ICF-MPLSOAM-PS-MIB.mib (10546 bytes)

Imported modules

HPN-ICF-OID-MIB SNMPv2-SMI SNMPv2-TC

Imported symbols

hpnicfCommon Integer32 Unsigned32
OBJECT-TYPE MODULE-IDENTITY NOTIFICATION-TYPE
TruthValue RowStatus

Defined Types

HpnicfMplsPsEntry  
SEQUENCE    
  hpnicfMplsPsIndex Integer32
  hpnicfMplsPsGroupID Integer32
  hpnicfMplsPsWorkLspName OCTET STRING
  hpnicfMplsPsProtectLspName OCTET STRING
  hpnicfMplsPsRevertiveMode Integer32
  hpnicfMplsPsWTR Integer32
  hpnicfMplsPsHoldOff Integer32
  hpnicfMplsPsSwitchCondition Integer32
  hpnicfMplsPsWorkLspDetectState Integer32
  hpnicfMplsPsWorkLspUpDownState Integer32
  hpnicfMplsPsProtLspDetectState Integer32
  hpnicfMplsPsProtLspUpDownState Integer32
  hpnicfMplsPsSwitchResult Integer32
  hpnicfMplsPsRowStatus RowStatus

Defined Values

hpnicfMplsOamPs 1.3.6.1.4.1.11.2.14.11.15.2.80
This MIB contains objects to configure mpls protect-switch module.
MODULE-IDENTITY    

hpnicfMplsOamPsScalarGroup 1.3.6.1.4.1.11.2.14.11.15.2.80.1
OBJECT IDENTIFIER    

hpnicfMplsOamPsTrapOpen 1.3.6.1.4.1.11.2.14.11.15.2.80.1.1
Whether mpls protect-switch trap is globally enabled. false: disable; true: enable
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpnicfMplsOamPsTable 1.3.6.1.4.1.11.2.14.11.15.2.80.2
OBJECT IDENTIFIER    

hpnicfMplsPsTable 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1
This table specifies per-protection-group MPLS PS capability and associated information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpnicfMplsPsEntry

hpnicfMplsPsEntry 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1
An entry in this table is created by an LSR for every protection group capable of supporting mpls ps.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpnicfMplsPsEntry  

hpnicfMplsPsIndex 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.1
This is a unique index for an entry in the mplspsEntry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hpnicfMplsPsGroupID 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.2
This is a unique group id for an entry in the mplspsEntry. One protect-switch group is composed of one working static-lsp and one protection static-lsp.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hpnicfMplsPsWorkLspName 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.3
The name of the working static-lsp.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

hpnicfMplsPsProtectLspName 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.4
The name of the protection static-lsp.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

hpnicfMplsPsRevertiveMode 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.5
Revertive mode is a protection switching mode where revertive action (switch back to the working LSP) is taken after the working LSP is repaired. And switching does not occur in a non-revertive mode. 1: revertive; 2: non-revertive;
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..2  

hpnicfMplsPsWTR 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.6
Wait to Restore timer is only applicable for the revertive mode and applies to a working LSP, it prevents reversion back to select the working LSP until the Wait to Restore timer has expired. The default value is 12 minutes. step is 30s.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hpnicfMplsPsHoldOff 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.7
The time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm. Step is 100ms, maximum is 10s.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

hpnicfMplsPsSwitchCondition 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.8
The current switch condition of the protection group. 1: clear, this command clears all of the externally initiated switch commands listed below; 2: lockout of protection, fix the selector position on the working LSP, Prevents the selector from switching to the protection LSP when it is selecting the working LSP. Switches the selector from the protection to the working LSP when it is selecting the protection LSP; 3: forced protection, switches the selector from the working LSP to the protection LSP (unless a higher priority switch request (i.e., LoP) is in effect); 4: signal fail, for 1:1, Signal Fail (SF) is declared when the source of the protection domain enters the Defect State by receiving a BDI packet (from the return LSP or out of band). 5: manual switch for working-lsp, switches the selector from the working LSP to the protection LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect); 6: manual switch for protection-lsp, switches the selector from the protection LSP to the working LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect). 7: WTR-timer, a configurable timer which is used to delay before reversion; 8: HoldOff-timer, the time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm; 9: Others; The pripority of the commands are: clear > lockout of protection > force switch > manual switch for working lsp = manual switch for protection lsp
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..9  

hpnicfMplsPsWorkLspDetectState 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.9
The state of working static-lsp state in one protection group, whether it is in defect: 1: it is out of defect; 2: it enters defect.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hpnicfMplsPsWorkLspUpDownState 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.10
The state of working static-lsp state in one protection group, whether it is up or down: 1: it is in up state; 2: it is in down state.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hpnicfMplsPsProtLspDetectState 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.11
The state of protection static-lsp state in one protection group, whether it is in detection: 1: it is out of defect; 2: it enters defect.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hpnicfMplsPsProtLspUpDownState 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.12
The state of protection static-lsp state in one protection group, whether it is up or down: 1: it is in up state; 2: it is in down state.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hpnicfMplsPsSwitchResult 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.13
Which tunnel is used to transfer the data stream. 1: working static-lsp; 2: protection static-lsp.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hpnicfMplsPsRowStatus 1.3.6.1.4.1.11.2.14.11.15.2.80.2.1.1.14
This object is responsible for managing the creation, deletion and modification of rows, which support active status and CreatAndGo, destroy operation. To create a new row, hpnicfMplsPsGroupID, hpnicfMplsPsWorkLspName, hpnicfMplsPsProtectLspName, hpnicfMplsPsRevertiveMode, hpnicfMplsPsWTR and hpnicfMplsPsHoldOff must be specified.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hpnicfMplsOamPsNotifications 1.3.6.1.4.1.11.2.14.11.15.2.80.3
OBJECT IDENTIFIER    

hpnicfMplsPsSwitchPtoW 1.3.6.1.4.1.11.2.14.11.15.2.80.3.1
This notification is generated when switching from protection-lsp to working-lsp occured.
Status: current Access: read-create
NOTIFICATION-TYPE    

hpnicfMplsPsSwitchWtoP 1.3.6.1.4.1.11.2.14.11.15.2.80.3.2
This notification is generated when switching from woking-lsp to protection-lsp occured.
Status: current Access: read-create
NOTIFICATION-TYPE