HUAWEI-DATASYNC-MIB

File: HUAWEI-DATASYNC-MIB.mib (14868 bytes)

Imported modules

HUAWEI-MIB SNMPv2-CONF SNMPv2-SMI
SNMPv2-TC

Imported symbols

hwDatacomm OBJECT-GROUP MODULE-COMPLIANCE
NOTIFICATION-GROUP TimeTicks Integer32
Gauge32 OBJECT-TYPE MODULE-IDENTITY
NOTIFICATION-TYPE DisplayString RowStatus
TEXTUAL-CONVENTION

Defined Types

DateAndTime  
A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present.
TEXTUAL-CONVENTION    
  OCTET STRING Size(8|11)  

HwCfgChgEntry  
SEQUENCE    
  hwCfgChgSeqID Integer32
  hwCfgChgTime DateAndTime
  hwCfgChgTerminalType INTEGER
  hwCfgChgTerminalID Integer32
  hwCfgChgType INTEGER
  hwCfgChgViewName OCTET STRING
  hwCfgChgCmdID Integer32
  hwCfgChgDetailInfo OCTET STRING

HwCollectEntry  
SEQUENCE    
  hwCollectIndex Integer32
  hwCollectNetManageId Integer32
  hwCollectOperation INTEGER
  hwCollectInScriptFile OCTET STRING
  hwCollectInResultFile OCTET STRING
  hwCollectState INTEGER
  hwCollectRowStatus RowStatus

Defined Values

hwDataSync 1.3.6.1.4.1.2011.5.25.191
The MIB module for Data sync between host and netmanager.
MODULE-IDENTITY    

hwDataSyncScalarObjects 1.3.6.1.4.1.2011.5.25.191.1
OBJECT IDENTIFIER    

hwDataSyncTableObjects 1.3.6.1.4.1.2011.5.25.191.2
OBJECT IDENTIFIER    

hwDataSyncNotifications 1.3.6.1.4.1.2011.5.25.191.3
OBJECT IDENTIFIER    

hwDataSyncConformance 1.3.6.1.4.1.2011.5.25.191.4
OBJECT IDENTIFIER    

hwCurrentCfgChgSeqID 1.3.6.1.4.1.2011.5.25.191.1.1
The value of this object identifies the ID of the current configuration change. The value ranges from 0 to 65535. After the ID of the configuration change reaches the maximum value, the value of the ID starts from 1 again. After the device is restarted, the value of the ID becomes 0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwCfgChgSeqIDReveralCount 1.3.6.1.4.1.2011.5.25.191.1.2
The value of this object identifies the cycle count of the index of configuration change table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwCfgChgTableMaxItem 1.3.6.1.4.1.2011.5.25.191.1.3
The value of this object identifies the maximum number of entries in hwCfgChgTable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwCfgBaselineTime 1.3.6.1.4.1.2011.5.25.191.1.4
Specifies the time of system confiuration was baseline.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

hwDataSyncGroups 1.3.6.1.4.1.2011.5.25.191.4.1
OBJECT IDENTIFIER    

hwDataSyncScalarObjectsGroup 1.3.6.1.4.1.2011.5.25.191.4.1.1
A collection of objects on DataSync ScalarObjects Information.
Status: current Access: read-only
OBJECT-GROUP    

hwCfgChgNotifyGroup 1.3.6.1.4.1.2011.5.25.191.4.1.2
A collection of objects on Configuration Change Information.
Status: current Access: read-only
NOTIFICATION-GROUP    

hwDataSyncCompliances 1.3.6.1.4.1.2011.5.25.191.4.2
OBJECT IDENTIFIER    

hwDataSyncCompliance 1.3.6.1.4.1.2011.5.25.191.4.2.1
The compliance statement for entities that support the huawei DataSync MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

hwCfgChgTable 1.3.6.1.4.1.2011.5.25.191.2.1
This table is used to record configuration changes. In this table, you can find the configuration change based on the specific index.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwCfgChgEntry

hwCfgChgEntry 1.3.6.1.4.1.2011.5.25.191.2.1.1
Entry of hwCfgChgTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwCfgChgEntry  

hwCfgChgSeqID 1.3.6.1.4.1.2011.5.25.191.2.1.1.1
The value of this object identifies the configuration change ID. When configuration is changed, the sequence id will plus 1.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

hwCfgChgTime 1.3.6.1.4.1.2011.5.25.191.2.1.1.2
This object indicates the configuration change time.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

hwCfgChgTerminalType 1.3.6.1.4.1.2011.5.25.191.2.1.1.3
This object indicates the type of the terminal.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER snmp(1), telnet(2), netconf(3)  

hwCfgChgTerminalID 1.3.6.1.4.1.2011.5.25.191.2.1.1.4
The value of this object identifies the terminal ID.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..15  

hwCfgChgType 1.3.6.1.4.1.2011.5.25.191.2.1.1.5
This object indicates the configuration change type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER create(1), modify(2), delete(3)  

hwCfgChgViewName 1.3.6.1.4.1.2011.5.25.191.2.1.1.6
This object indicates the name of the view in which the configuration change occurs. For the command operation, the object is the name of the view in which the command is run. For the SNMP operation, the object is the OID of the MIB table or the scalar object.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hwCfgChgCmdID 1.3.6.1.4.1.2011.5.25.191.2.1.1.7
The value of this object identifies the ID of the configuration change command. For the SNMP operation, the value is 0.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwCfgChgDetailInfo 1.3.6.1.4.1.2011.5.25.191.2.1.1.8
This object indicates detailed configuration change information. For the command operation, the object is the command line. For the SNMP operation, the object is the index of the MIB table. When there are multiple indexes, the format of index1.index2.index3 is adopted.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hwCollectTable 1.3.6.1.4.1.2011.5.25.191.2.2
This table is used to enable the NMS to send the collecting script to the device to trigger the collection, and then monitor the collection status.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwCollectEntry

hwCollectEntry 1.3.6.1.4.1.2011.5.25.191.2.2.1
Entry of hwCollectTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwCollectEntry  

hwCollectIndex 1.3.6.1.4.1.2011.5.25.191.2.2.1.1
The value of this object identifies the collection index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

hwCollectNetManageId 1.3.6.1.4.1.2011.5.25.191.2.2.1.2
The value of this object identifies the NMS ID.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hwCollectOperation 1.3.6.1.4.1.2011.5.25.191.2.2.1.3
This object indicates the instruction for the collection operation. Default value is stop.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER begin(1), stop(2)  

hwCollectInScriptFile 1.3.6.1.4.1.2011.5.25.191.2.2.1.4
This object indicates the name of the script file. T he length of the file name ranges from 1 character to 255 characters.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

hwCollectInResultFile 1.3.6.1.4.1.2011.5.25.191.2.2.1.5
This object indicates the name of the result file. The length of the file name ranges from 1 character to 255 characters.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..255)  

hwCollectState 1.3.6.1.4.1.2011.5.25.191.2.2.1.6
This object indicates the collection status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), collecting(2)  

hwCollectRowStatus 1.3.6.1.4.1.2011.5.25.191.2.2.1.7
This object indicates the row status.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwCfgChgNotify 1.3.6.1.4.1.2011.5.25.191.3.1
This trap is generated when a configuration change occurs on the device within a specified period.
Status: current Access: read-create
NOTIFICATION-TYPE