HUAWEI-MPLSOAM-MIB

File: HUAWEI-MPLSOAM-MIB.mib (95516 bytes)

Imported modules

HUAWEI-MIB SNMPv2-SMI SNMPv2-CONF
SNMPv2-TC HUAWEI-MPLS-EXTEND-MIB IF-MIB

Imported symbols

hwMpls IpAddress Integer32
Unsigned32 OBJECT-TYPE MODULE-IDENTITY
NOTIFICATION-TYPE OBJECT-GROUP MODULE-COMPLIANCE
NOTIFICATION-GROUP DisplayString TruthValue
TimeStamp RowStatus TEXTUAL-CONVENTION
hwMplsTunnelSignalProto InterfaceIndex

Defined Types

HwMplsOamIgrEntry  
SEQUENCE    
  hwMplsOamIgrIndex Unsigned32
  hwMplsOamIgrTunnName OCTET STRING
  hwMplsOamIgrDetType INTEGER
  hwMplsOamIgrDetFreq INTEGER
  hwMplsOamIgrRevType INTEGER
  hwMplsOamIgrRevLspName OCTET STRING
  hwMplsOamIgrRevLsrId IpAddress
  hwMplsOamIgrRevSessTunnId Integer32
  hwMplsOamIgrEnable INTEGER
  hwMplsOamIgrValid INTEGER
  hwMplsOamIgrAvaState INTEGER
  hwMplsOamIgrDefectType INTEGER
  hwMplsOamIgrCompatibilityMode INTEGER
  hwMplsOamIgrBDIFreq INTEGER
  hwMplsOamIgrRowStatus RowStatus

HwMplsOamEgrEntry  
SEQUENCE    
  hwMplsOamEgrLspName OCTET STRING
  hwMplsOamEgrLsrId IpAddress
  hwMplsOamEgrSessTunnId Integer32
  hwMplsOamEgrDetType INTEGER
  hwMplsOamEgrDetFreq INTEGER
  hwMplsOamEgrRevType INTEGER
  hwMplsOamEgrRevTunnName OCTET STRING
  hwMplsOamEgrAutoEn INTEGER
  hwMplsOamEgrAutoOvertime Integer32
  hwMplsOamEgrBDIFreq INTEGER
  hwMplsOamEgrEnable INTEGER
  hwMplsOamEgrValid INTEGER
  hwMplsOamEgrAvaState INTEGER
  hwMplsOamEgrDefectType INTEGER
  hwMplsOamEgrRowStatus RowStatus

HwMplsOamRlsnEntry  
SEQUENCE    
  hwMplsOamRlsnLspName OCTET STRING
  hwMplsOamRlsnLsrId IpAddress
  hwMplsOamRlsnSessTunnId Integer32
  hwMplsOamRlsnIfIndex Integer32
  hwMplsOamRlsnIfName OCTET STRING
  hwMplsOamRlsnIsDown INTEGER
  hwMplsOamRlsnRowStatus RowStatus

HwMplsOamL2vcEntry  
SEQUENCE    
  hwMplsOamL2vcPeerIp IpAddress
  hwMplsOamL2vcVcType INTEGER
  hwMplsOamL2vcVcId Unsigned32
  hwMplsOamL2vcRemotePeerIp IpAddress
  hwMplsOamL2vcRemoteVcType INTEGER
  hwMplsOamL2vcRemoteVcId Unsigned32
  hwMplsOamL2vcDetType INTEGER
  hwMplsOamL2vcDetFreq INTEGER
  hwMplsOamL2vcRevDetType INTEGER
  hwMplsOamL2vcRevDetFreq INTEGER
  hwMplsOamL2vcSendEnable INTEGER
  hwMplsOamL2vcReceiveEnable INTEGER
  hwMplsOamL2vcAutoProlEn INTEGER
  hwMplsOamL2vcAutoOvertime Integer32
  hwMplsOamL2vcValid INTEGER
  hwMplsOamL2vcAvaState INTEGER
  hwMplsOamL2vcDefectType INTEGER
  hwMplsOamL2vcBdiDefectType INTEGER
  hwMplsOamL2vcCompatibilityMode INTEGER
  hwMplsOamL2vcBDIFreq INTEGER
  hwMplsOamL2vcRowStatus RowStatus

HwMplsOamBidirectionalTunnelEntry  
SEQUENCE    
  hwMplsOamBidirectionalTunnelIndex Unsigned32
  hwMplsOamBidirectionalTunnelTunnName OCTET STRING
  hwMplsOamBidirectionalTunnelDetType INTEGER
  hwMplsOamBidirectionalTunnelDetFreq INTEGER
  hwMplsOamBidirectionalTunnelRevDetType INTEGER
  hwMplsOamBidirectionalTunnelRevDetFreq INTEGER
  hwMplsOamBidirectionalTunnelSendEnable INTEGER
  hwMplsOamBidirectionalTunnelReceiveEnable INTEGER
  hwMplsOamBidirectionalTunnelAutoProtocolEnable INTEGER
  hwMplsOamBidirectionalTunnelAutoOvertime Integer32
  hwMplsOamBidirectionalTunnelValid INTEGER
  hwMplsOamBidirectionalTunnelAvaState INTEGER
  hwMplsOamBidirectionalTunnelDefectType INTEGER
  hwMplsOamBidirectionalTunnelBdiDefectType INTEGER
  hwMplsOamBidirectionalTunnelCompatibilityMode INTEGER
  hwMplsOamBidirectionalTunnelBDIFreq INTEGER
  hwMplsOamBidirectionalTunnelRowStatus RowStatus

HwMplsPsEntry  
SEQUENCE    
  hwMplsPsIndex Unsigned32
  hwMplsPsType Integer32
  hwMplsPsWorkTunnName OCTET STRING
  hwMplsPsWorkTunnId Integer32
  hwMplsPsProtectTunnName OCTET STRING
  hwMplsPsProtectTunnId Integer32
  hwMplsPsRevertiveMode Integer32
  hwMplsPsWTR Integer32
  hwMplsPsHoldOff Integer32
  hwMplsPsSwitchCondition Integer32
  hwMplsPsWorkTunnelState Integer32
  hwMplsPsProtTunnelState Integer32
  hwMplsPsSwitchResult Integer32
  hwMplsPsCfgType Integer32
  hwMplsPsCfgProtectTunnId Integer32
  hwMplsPsCfgRevertiveMode Integer32
  hwMplsPsCfgWTR Integer32
  hwMplsPsCfgHoldOff Integer32
  hwMplsPsRowStatus RowStatus
  hwMplsPsLocalState Integer32

HwMplsVCPsEntry  
SEQUENCE    
  hwMplsVCPsIfIndex InterfaceIndex
  hwMplsVCPsTNLBinding TruthValue
  hwMplsTeReverseLspName OCTET STRING
  hwMplsVcPsRowStatus RowStatus
  hwMplsTeReverseLspLsrId IpAddress
  hwMplsTeReverseLspTunnId Integer32

Defined Values

hwMplsOam 1.1.2011.5.12.7
The HUAWEI-MPLSOAM-MIB contains objects to configure OAM module. The Operation, Administration and Maintenance (OAM) is an effective means for decreasing the cost of network maintenance. The MPLS OAM is used to administrate and maintain MPLS.
MODULE-IDENTITY    

hwMplsOamPs 1.1.2011.5.12.7.1
OBJECT IDENTIFIER    

hwMplsOamObjects 1.1.2011.5.12.7.1.1
OBJECT IDENTIFIER    

hwMplsOamCapability 1.1.2011.5.12.7.1.1.1
Whether OAM is globally capable. 0: incapable; 1: capable; 2: capable(basedItu); The default value is incapable.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

hwMplsOamIgrTable 1.1.2011.5.12.7.1.1.2
This table specifies per-LSP MPLS OAM capability and associated information, such as IgrTunnName and IgrDetType.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMplsOamIgrEntry

hwMplsOamIgrEntry 1.1.2011.5.12.7.1.1.2.1
An entry in this table is created by an LSR for every LSP capable of supporting MPLS OAM at ingress.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMplsOamIgrEntry  

hwMplsOamIgrIndex 1.1.2011.5.12.7.1.1.2.1.1
The interface index of the detected tunnel.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32  

hwMplsOamIgrTunnName 1.1.2011.5.12.7.1.1.2.1.2
The name of a tunnel. For ingress, it means the tunnel name of the detected LSP. For egress, it means the tunnel name of the reverse LSP.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

hwMplsOamIgrDetType 1.1.2011.5.12.7.1.1.2.1.3
There are two types of OAM packets, CV and FFD. The CV flow is generated at the source LSR of the LSP with a nominal frequency of 1/s and terminated at the sink LSR of the LSP. FFD provides failure detection option for an LSP independent of the CV based availability model and is not tied to the CV insertion rate. Insertion rates at 1/s or faster may also be used. The CV/FFD packet contains a network-unique identifier (TTSI) so that all types of defects can be detected. 1: CV; 2: FFD.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cv(1), ffd(2)  

hwMplsOamIgrDetFreq 1.1.2011.5.12.7.1.1.2.1.4
For CV: the frequency is static, per second. For FFD: the frequency is set by user. The value can be 10ms, 20ms, 50ms,100ms,200ms,500ms,3ms. Any other frequency is wrong. 0: 1000ms(only for cv); 1: 10ms; 2: 20ms; 3: 50ms; 4: 100ms; 5: 200ms; 6: 500ms; 7: 3ms.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cv1000ms(0), ffd10ms2(1), ffd20ms3(2), ffd50ms4(3), ffd100ms5(4), ffd200ms6(5), ffd500ms7(6), ffd3ms8(7)  

hwMplsOamIgrRevType 1.1.2011.5.12.7.1.1.2.1.5
When an LSP is found to be in defect, the sink LSR if the LSP should send BDI to inform the source LSR of the LSP, the BDI is transferred through the reverse LSP. The type of reverse LSP can be private or shared. If private, then the reverse LSP can be used only when the only LSP is in defect; If shared, the reverse LSP which is shared between many forward LSPs, whose source LSRs are the same and sink LSRs are the same. 1: private; 2: share.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER private(1), share(2)  

hwMplsOamIgrRevLspName 1.1.2011.5.12.7.1.1.2.1.6
The object indicates name of the reverse LSP.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

hwMplsOamIgrRevLsrId 1.1.2011.5.12.7.1.1.2.1.7
Only for ingress, the object indicates the ingress LSR ID of the reverse LSP,, expressed in IP address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

hwMplsOamIgrRevSessTunnId 1.1.2011.5.12.7.1.1.2.1.8
Only for ingress, the object indicates the session tunnel ID of the reverse LSP.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..65535  

hwMplsOamIgrEnable 1.1.2011.5.12.7.1.1.2.1.9
Whether one LSP is OAM enable. If disable, LSP is not monitored; If enable, CV/FFD is generated at the source LSR of the LSP and checked at the sink LSR of the LSP,and user can set other configuration. 0: The OAM function is disabled on the ingress; 1: The OAM function is enabled on the ingress.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

hwMplsOamIgrValid 1.1.2011.5.12.7.1.1.2.1.10
0: stop detect; 1: start detect.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stop(0), start(1)  

hwMplsOamIgrAvaState 1.1.2011.5.12.7.1.1.2.1.11
If the LSP Timer (T1) expires, then the LSP enters the Unavailable state. The start point of the Unavailable state is deemed to be at the entry into the LSP defect state. An LSP re-enters the Available state after the LSP Defect state exists first. T1 defines the length of time the LSP is in the Defect state before declaring an LSP Unavailable or returning to defect free state. 0: available state; 1: unavailable state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER available(0), unavailable(1)  

hwMplsOamIgrDefectType 1.1.2011.5.12.7.1.1.2.1.12
Defect is defined as interruption of the capability of a transport entity (e.g., network connection) to transfer user or OAM information. There are six types of defect: 0: no defect; 1: dServer; 2: dPeerMe; 3: dLOCV, Loss of Connectivity Verification defect; 4: dTTSIMismatch, Trail Termination Source Identifier Mismatch defect; 5: dTTSIMismerge, Trail Termination Source Identifier Mismerge defect; 6: dExcess, Receiving excess rate of CV/FFD; 7: dUnknown, Unknown defect in the MPLS network.. 8: dOamFail, AutoProtocal timer expires. 9: dIngressDown.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nondefect(0), dServer(1), dPeerMe(2), dLOCV(3), dTTSIMismatch(4), dTTSIMismerge(5), dExcess(6), dUnknown(7), dOamFail(8), dIngressDown(9)  

hwMplsOamIgrRowStatus 1.1.2011.5.12.7.1.1.2.1.13
This variable is used to create, modify, and delete a row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwMplsOamIgrCompatibilityMode 1.1.2011.5.12.7.1.1.2.1.14
1: PtnMode; 2: RouterMode; Valid only for the ingress configuration.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ptnMode(1), routerMode(2)  

hwMplsOamIgrBDIFreq 1.1.2011.5.12.7.1.1.2.1.15
BDI is generated at the trail termination source point of a return path in response to a defect detected at the trail termination sink point of an LSP in the forwarding direction. The frequency of BDI can be set by user. 1: perSecond; 2: same as detect frequency.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER perSecond(1), detectFrequency(2)  

hwMplsOamEgrTable 1.1.2011.5.12.7.1.1.3
This table specifies per-LSP MPLS OAM capability and associated information, such as DetectType, DetectFrequency.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMplsOamEgrEntry

hwMplsOamEgrEntry 1.1.2011.5.12.7.1.1.3.1
An entry in this table is created by an LSR for every LSP capable of supporting MPLS OAM at egress.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMplsOamEgrEntry  

hwMplsOamEgrLspName 1.1.2011.5.12.7.1.1.3.1.1
The object indicates the name of static LSP at egress.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING  

hwMplsOamEgrLsrId 1.1.2011.5.12.7.1.1.3.1.2
The object indicates the Ingress LSR ID of the LSP.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  IpAddress  

hwMplsOamEgrSessTunnId 1.1.2011.5.12.7.1.1.3.1.3
The object indicates the the Ingress session tunnel ID of the LSP..
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 0..65535  

hwMplsOamEgrDetType 1.1.2011.5.12.7.1.1.3.1.4
0: invalid, if auto-protocol, this detect type is invalid; 1: CV; 2: FFD.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER invalid(0), cv(1), ffd(2)  

hwMplsOamEgrDetFreq 1.1.2011.5.12.7.1.1.3.1.5
0: 1000ms(only for cv); 1: 10ms; 2: 20ms; 3: 50ms; 4: 100ms; 5: 200ms; 6: 500ms; 7: invalid; 8: 3ms.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cv1000ms(0), ffd10ms2(1), ffd20ms3(2), ffd50ms4(3), ffd100ms5(4), ffd200ms6(5), ffd500ms7(6), invalid8(7), ffd3ms9(8)  

hwMplsOamEgrRevType 1.1.2011.5.12.7.1.1.3.1.6
When an LSP is found to be in defect, the sink LSR of the LSP should send BDI to inform the source LSR of the LSP,the BDI is transferred through the reverse LSP. The type of reverse LSP can be private or shared. If private, then the reverse LSP can be used only when the only LSP in defect; If shared, the reverse LSP, which is shared between many forward LSPs that have the same source LSRs and sink LSRs. 0: invalid, when the reverse LSR does not exist; 1: private; 2: share.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER invalid(0), private(1), share(2)  

hwMplsOamEgrRevTunnName 1.1.2011.5.12.7.1.1.3.1.7
The object indicates the name of a reverse tunnel.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

hwMplsOamEgrAutoEn 1.1.2011.5.12.7.1.1.3.1.8
If autoprotocol, then the egress can process extended FDI sent by ingress. 0: disable; 1: enable; Valid only for the egress configuration.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

hwMplsOamEgrAutoOvertime 1.1.2011.5.12.7.1.1.3.1.9
This time is set at the egress. If the egress receives CV/FFD, it records the parameters included in the packet, such as OAM type and frequency. If the egress does not receive any OAM packet before the timer expires, the sink LSR will send BDI with dLOCV defect. Valid only for the egress configuration.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..255  

hwMplsOamEgrBDIFreq 1.1.2011.5.12.7.1.1.3.1.10
BDI is generated at the trail termination source point of a return path in response to a defect detected at the trail termination sink point of an LSP in the forwarding direction. The frequency of BDI can be set by user. Only valid for egress configuration. The default value is detect frequency and it is valid only when a backward-LSP exists. 0: perSecond; 1: same as detect frequency.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER perSecond(0), detectFrequency(1)  

hwMplsOamEgrEnable 1.1.2011.5.12.7.1.1.3.1.11
Whether one LSP is enabled with OAM. If disable, LSP is not monitored; If enable, CV/FFD is generated at the source LSR of the LSP and checked at the sink LSR of the LSP, and user can set other configuration. 0: The OAM function is disabled on the egress; 1: The OAM function is enabled on the egress.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

hwMplsOamEgrValid 1.1.2011.5.12.7.1.1.3.1.12
1: stop detect; 2: start detect.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stop(1), start(2)  

hwMplsOamEgrAvaState 1.1.2011.5.12.7.1.1.3.1.13
If the LSP Timer (T1) expires, then the LSP enters the Unavailable state. The start point of the Unavailable state is deemed to be at the entry into the LSP defect state. An LSP re-enters the Available state after the LSP Defect State. first exists. T1 defines the length of time the LSP is in the Defect state before declaring an LSP Unavailable or returning to defect free state 0: available state; 1: unavailable state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER available(0), unavailable(1)  

hwMplsOamEgrDefectType 1.1.2011.5.12.7.1.1.3.1.14
0: no defect; 1: dServer, 2: dPeerMe, 3: dLOCV, Loss of Connectivity Verification defect; 4: dTTSIMismatch, Trail Termination Source Identifier Mismatch defect; 5: dTTSIMismerge, Trail Termination Source Identifier Mismerge defect.; 6: dExcess, Receiving excess rate of CV/FFD; 7: dUnknown, Unknown defect in the MPLS network. 8: dOamFail, AutoProtocal timer expires. 9: dEgressDown.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nondefect(0), dServer(1), dPeerMe(2), dLOCV(3), dTTSIMismatch(4), dTTSIMismerge(5), dExcess(6), dUnknown(7), dOamFail(8), dEgressDown(9)  

hwMplsOamEgrRowStatus 1.1.2011.5.12.7.1.1.3.1.15
This variable is used to create, modify, and delete a row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwMplsOamRlsnTable 1.1.2011.5.12.7.1.1.4
This table specifies RLSN capability and associated information, such as RlsnLsrId and RlsnLsrId.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMplsOamRlsnEntry

hwMplsOamRlsnEntry 1.1.2011.5.12.7.1.1.4.1
An entry in this table is created by an LSR to binding the name, lsr-id and tunnel-id of the LSP at egress.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMplsOamRlsnEntry  

hwMplsOamRlsnLspName 1.1.2011.5.12.7.1.1.4.1.1
For egress, the object indicates name of the LSP.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

hwMplsOamRlsnLsrId 1.1.2011.5.12.7.1.1.4.1.2
For egress, the object indicates the Ingress LSR ID of the LSP
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

hwMplsOamRlsnSessTunnId 1.1.2011.5.12.7.1.1.4.1.3
For egress, the object indicates the Ingress session tunnel ID of the LSP
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..65535  

hwMplsOamRlsnIfIndex 1.1.2011.5.12.7.1.1.4.1.4
The object indicates the index of outbound interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hwMplsOamRlsnIfName 1.1.2011.5.12.7.1.1.4.1.5
The object indicates the name of outbound interface.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

hwMplsOamRlsnIsDown 1.1.2011.5.12.7.1.1.4.1.6
1: up 2: down
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

hwMplsOamRlsnRowStatus 1.1.2011.5.12.7.1.1.4.1.7
This variable is used to create, modify, and delete a row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwMplsOamView 1.1.2011.5.12.7.1.1.5
Create or delete the MPLS OAM view. 1: create mplsOam; 0: delete mplsOam;
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER mplsOam(1), null(0)  

hwMplsOamL2vcTable 1.1.2011.5.12.7.1.1.6
This table specifies PW MPLS OAM capability and associated information, such as DetType and DetFrequence.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMplsOamL2vcEntry

hwMplsOamL2vcEntry 1.1.2011.5.12.7.1.1.6.1
An entry in this table is created by binding the peer-ip, vc-type and vc-id.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMplsOamL2vcEntry  

hwMplsOamL2vcPeerIp 1.1.2011.5.12.7.1.1.6.1.1
This object indicates the peer ip address.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  IpAddress  

hwMplsOamL2vcVcType 1.1.2011.5.12.7.1.1.6.1.2
There are seventeen types of vc. 1: fr; 2: atmAal5Sdu; 3: atmTransCell; 4: vlan; 5: ethernet; 6: hdlc; 7: ppp; 9: atmNto1Vcc; 10:atmNto1Vpc; 11:ipLayer2; 12:atm1to1Vcc; 13:atm1to1Vpc; 14:atmAal5Pdu; 16:cep; 17:satopE1; 18:satopT1; 21:cesopsnBasic; 64:ipInterworking; 0:unknown.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER fr(1), atmAal5Sdu(2), atmTransCell(3), vlan(4), ethernet(5), hdlc(6), ppp(7), atmNto1Vcc(9), atmNto1Vpc(10), ipLayer2(11), atm1to1Vcc(12), atm1to1Vpc(13), atmAal5Pdu(14), cep(16), satopE1(17), satopT1(18), cesopsnBasic(21), ipInterworking(64), unknown(0)  

hwMplsOamL2vcVcId 1.1.2011.5.12.7.1.1.6.1.3
This object indicates the vc id of pw type.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32  

hwMplsOamL2vcRemotePeerIp 1.1.2011.5.12.7.1.1.6.1.4
This object indicates the remote peer ip address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

hwMplsOamL2vcRemoteVcType 1.1.2011.5.12.7.1.1.6.1.5
There are seventeen types of vc. 1: fr; 2: atmAal5Sdu; 3: atmTransCell; 4: vlan; 5: ethernet; 6: hdlc; 7: ppp; 9: atmNto1Vcc; 10:atmNto1Vpc; 11:ipLayer2; 12:atm1to1Vcc; 13:atm1to1Vpc; 14:atmAal5Pdu; 16:cep; 17:satopE1; 18:satopT1; 21:cesopsnBasic; 64:ipInterworking; 0:unknown.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER fr(1), atmAal5Sdu(2), atmTransCell(3), vlan(4), ethernet(5), hdlc(6), ppp(7), atmNto1Vcc(9), atmNto1Vpc(10), ipLayer2(11), atm1to1Vcc(12), atm1to1Vpc(13), atmAal5Pdu(14), cep(16), satopE1(17), satopT1(18), cesopsnBasic(21), ipInterworking(64), unknown(0)  

hwMplsOamL2vcRemoteVcId 1.1.2011.5.12.7.1.1.6.1.6
This object indicates the remote vc id of pw type.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

hwMplsOamL2vcDetType 1.1.2011.5.12.7.1.1.6.1.7
There are two types of OAM packets, CV and FFD. 1: CV; 2: FFD.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cv(1), ffd(2)  

hwMplsOamL2vcDetFreq 1.1.2011.5.12.7.1.1.6.1.8
For CV: the frequency is static, per second. For FFD: the frequency is set by user. The value can be 10ms, 20ms, 50ms,100ms,200ms,500ms,3ms. Any other frequency is wrong. 0: 1000ms(only for cv); 1: 10ms; 2: 20ms; 3: 50ms; 4: 100ms; 5: 200ms; 6: 500ms; 7: 3ms.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cv1000ms(0), ffd10ms2(1), ffd20ms3(2), ffd50ms4(3), ffd100ms5(4), ffd200ms6(5), ffd500ms7(6), ffd3ms8(7)  

hwMplsOamL2vcRevDetType 1.1.2011.5.12.7.1.1.6.1.9
0: invalid; 1: CV; 2: FFD.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER invalid(0), cv(1), ffd(2)  

hwMplsOamL2vcRevDetFreq 1.1.2011.5.12.7.1.1.6.1.10
For CV: the frequency is static, per second. For FFD: the frequency is set by user. The value can be 10ms, 20ms, 50ms,100ms,200ms,500ms,3ms. Any other frequency is wrong. 0: 1000ms(only for cv); 1: 10ms; 2: 20ms; 3: 50ms; 4: 100ms; 5: 200ms; 6: 500ms; 7: invalid; 8: 3ms.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cv1000ms(0), ffd10ms2(1), ffd20ms3(2), ffd50ms4(3), ffd100ms5(4), ffd200ms6(5), ffd500ms7(6), invalid8(7), ffd3ms9(8)  

hwMplsOamL2vcSendEnable 1.1.2011.5.12.7.1.1.6.1.11
0: The OAM Send function is Disabled; 1: The OAM Send function is Eabled;
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

hwMplsOamL2vcReceiveEnable 1.1.2011.5.12.7.1.1.6.1.12
0: The OAM Receive function is Disabled; 1: The OAM Receive function is Eabled;
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

hwMplsOamL2vcAutoProlEn 1.1.2011.5.12.7.1.1.6.1.13
0: disable; 1: enable;
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

hwMplsOamL2vcAutoOvertime 1.1.2011.5.12.7.1.1.6.1.14
If the oam receives CV/FFD, it records the parameters included in the packet, such as OAM type and frequency. If the oam does not receive any CV/FFD packet before the timer expires, It will send BDI with dLOCV defect.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..255  

hwMplsOamL2vcValid 1.1.2011.5.12.7.1.1.6.1.15
1: stop detect; 2: start detect; 3: ready.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stop(1), start(2), ready(3)  

hwMplsOamL2vcAvaState 1.1.2011.5.12.7.1.1.6.1.16
0: available state; 1: unavailable state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER available(0), unavailable(1)  

hwMplsOamL2vcDefectType 1.1.2011.5.12.7.1.1.6.1.17
0: no defect; 1: dServer, 2: dPeerMe, 3: dLOCV, Loss of Connectivity Verification defect; 4: dTTSIMismatch, Trail Termination Source Identifier Mismatch defect; 5: dTTSIMismerge, Trail Termination Source Identifier Mismerge defect.; 6: dExcess, Receiving excess rate of CV/FFD; 7: dUnknown, Unknown defect in the MPLS network. 8: dOamFail, AutoProtocal timer expires. 9: pwDown, PW down.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nondefect(0), dServer(1), dPeerMe(2), dLOCV(3), dTTSIMismatch(4), dTTSIMismerge(5), dExcess(6), dUnknown(7), dOamFail(8), pwDown(9)  

hwMplsOamL2vcBdiDefectType 1.1.2011.5.12.7.1.1.6.1.18
0: no defect; 1: dServer, 2: dPeerMe, 3: dLOCV, Loss of Connectivity Verification defect; 4: dTTSIMismatch, Trail Termination Source Identifier Mismatch defect; 5: dTTSIMismerge, Trail Termination Source Identifier Mismerge defect.; 6: dExcess, Receiving excess rate of CV/FFD; 7: dUnknown, Unknown defect in the MPLS network. 8: dOamFail, AutoProtocal timer expires.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nondefect(0), dServer(1), dPeerMe(2), dLOCV(3), dTTSIMismatch(4), dTTSIMismerge(5), dExcess(6), dUnknown(7), dOamFail(8)  

hwMplsOamL2vcRowStatus 1.1.2011.5.12.7.1.1.6.1.30
This variable is used to create, modify, and delete a row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwMplsOamL2vcCompatibilityMode 1.1.2011.5.12.7.1.1.6.1.31
1: ptnMode; 2: routerMode; Valid only for the l2vc configuration.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ptnMode(1), routerMode(2)  

hwMplsOamL2vcBDIFreq 1.1.2011.5.12.7.1.1.6.1.32
BDI is generated at the trail termination source point of a return path in response to a defect detected at the trail termination sink point of an LSP in the forwarding direction. The frequency of BDI can be set by user. 1: perSecond; 2: same as detect frequency.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER perSecond(1), detectFrequency(2)  

hwMplsOamBidirectionalTunnelTable 1.1.2011.5.12.7.1.1.7
This table specifies Static Co-Route MPLS OAM capability and associated information, such as DetType and DetFrequence.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMplsOamBidirectionalTunnelEntry

hwMplsOamBidirectionalTunnelEntry 1.1.2011.5.12.7.1.1.7.1
An entry in this table is created by binding the tunnel ifindex.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMplsOamBidirectionalTunnelEntry  

hwMplsOamBidirectionalTunnelIndex 1.1.2011.5.12.7.1.1.7.1.1
This is a unique index for an OAM entry in the OAM table.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Unsigned32  

hwMplsOamBidirectionalTunnelTunnName 1.1.2011.5.12.7.1.1.7.1.2
The name of a tunnel.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

hwMplsOamBidirectionalTunnelDetType 1.1.2011.5.12.7.1.1.7.1.3
There are two types of OAM packets, CV and FFD. 1: CV; 2: FFD.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cv(1), ffd(2)  

hwMplsOamBidirectionalTunnelDetFreq 1.1.2011.5.12.7.1.1.7.1.4
For CV: the frequency is static, per second. For FFD: the frequency is set by user. The value can be 10ms, 20ms, 50ms,100ms,200ms,500ms,3ms. Any other frequency is wrong. 0: 1000ms(only for cv); 1: 10ms; 2: 20ms; 3: 50ms; 4: 100ms; 5: 200ms; 6: 500ms; 7: 3ms.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cv1000ms(0), ffd10ms2(1), ffd20ms3(2), ffd50ms4(3), ffd100ms5(4), ffd200ms6(5), ffd500ms7(6), ffd3ms8(7)  

hwMplsOamBidirectionalTunnelRevDetType 1.1.2011.5.12.7.1.1.7.1.5
0: invalid; 1: CV; 2: FFD.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER invalid(0), cv(1), ffd(2)  

hwMplsOamBidirectionalTunnelRevDetFreq 1.1.2011.5.12.7.1.1.7.1.6
For CV: the frequency is static, per second. For FFD: the frequency is set by user. The value can be 10ms, 20ms, 50ms,100ms,200ms,500ms,3ms. Any other frequency is wrong. 0: 1000ms(only for cv); 1: 10ms; 2: 20ms; 3: 50ms; 4: 100ms; 5: 200ms; 6: 500ms; 7: invalid; 8: 3ms.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cv1000ms(0), ffd10ms2(1), ffd20ms3(2), ffd50ms4(3), ffd100ms5(4), ffd200ms6(5), ffd500ms7(6), invalid8(7), ffd3ms9(8)  

hwMplsOamBidirectionalTunnelSendEnable 1.1.2011.5.12.7.1.1.7.1.7
0: The OAM Send function is Disabled; 1: The OAM Send function is Eabled;
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

hwMplsOamBidirectionalTunnelReceiveEnable 1.1.2011.5.12.7.1.1.7.1.8
0: The OAM Receive function is Disabled; 1: The OAM Receive function is Eabled;
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

hwMplsOamBidirectionalTunnelAutoProtocolEnable 1.1.2011.5.12.7.1.1.7.1.9
0: disable; 1: enable;
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

hwMplsOamBidirectionalTunnelAutoOvertime 1.1.2011.5.12.7.1.1.7.1.10
If the oam receives CV/FFD, it records the parameters included in the packet, such as OAM type and frequency. If the oam does not receive any CV/FFD packet before the timer expires, It will send BDI with dLOCV defect.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..255  

hwMplsOamBidirectionalTunnelValid 1.1.2011.5.12.7.1.1.7.1.11
1: stop detect; 2: start detect; 3: ready.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stop(1), start(2), ready(3)  

hwMplsOamBidirectionalTunnelAvaState 1.1.2011.5.12.7.1.1.7.1.12
0: available state; 1: unavailable state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER available(0), unavailable(1)  

hwMplsOamBidirectionalTunnelDefectType 1.1.2011.5.12.7.1.1.7.1.13
0: no defect; 1: dServer, 2: dPeerMe, 3: dLOCV, Loss of Connectivity Verification defect; 4: dTTSIMismatch, Trail Termination Source Identifier Mismatch defect; 5: dTTSIMismerge, Trail Termination Source Identifier Mismerge defect.; 6: dExcess, Receiving excess rate of CV/FFD; 7: dUnknown, Unknown defect in the MPLS network. 8: dOamFail, AutoProtocal timer expires. 9: corouteDown, coroute down.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nondefect(0), dServer(1), dPeerMe(2), dLOCV(3), dTTSIMismatch(4), dTTSIMismerge(5), dExcess(6), dUnknown(7), dOamFail(8), corouteDown(9)  

hwMplsOamBidirectionalTunnelBdiDefectType 1.1.2011.5.12.7.1.1.7.1.14
0: no defect; 1: dServer, 2: dPeerMe, 3: dLOCV, Loss of Connectivity Verification defect; 4: dTTSIMismatch, Trail Termination Source Identifier Mismatch defect; 5: dTTSIMismerge, Trail Termination Source Identifier Mismerge defect.; 6: dExcess, Receiving excess rate of CV/FFD; 7: dUnknown, Unknown defect in the MPLS network. 8: dOamFail, AutoProtocal timer expires.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nondefect(0), dServer(1), dPeerMe(2), dLOCV(3), dTTSIMismatch(4), dTTSIMismerge(5), dExcess(6), dUnknown(7), dOamFail(8)  

hwMplsOamBidirectionalTunnelRowStatus 1.1.2011.5.12.7.1.1.7.1.15
This variable is used to create, modify, and delete a row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwMplsOamBidirectionalTunnelCompatibilityMode 1.1.2011.5.12.7.1.1.7.1.16
1: ptnMode; 2: routerMode; Valid only for the bidirectional tunnel configuration.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ptnMode(1), routerMode(2)  

hwMplsOamBidirectionalTunnelBDIFreq 1.1.2011.5.12.7.1.1.7.1.17
BDI is generated at the trail termination source point of a return path in response to a defect detected at the trail termination sink point of an LSP in the forwarding direction. The frequency of BDI can be set by user. 1: perSecond; 2: same as detect frequency.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER perSecond(1), detectFrequency(2)  

hwMplsOamTrapOpen 1.1.2011.5.12.7.1.1.8
0: disable 1: enable
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

hwMplsOamNotifications 1.1.2011.5.12.7.1.2
OBJECT IDENTIFIER    

hwMplsOamIgrLSPOutDefect 1.1.2011.5.12.7.1.2.1
This notification is generated when the LSP is found not in the defect state at the LSP ingress.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamIgrLSPInDefect 1.1.2011.5.12.7.1.2.2
This notification is generated when the LSP is found in the defect state at the LSP ingress.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamIgrLSPAva 1.1.2011.5.12.7.1.2.3
This notification is generated when the LSP is found in the available state at the LSP ingress.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamIgrLSPUnAva 1.1.2011.5.12.7.1.2.4
This notification is generated when the LSP is found in the unavailable state at the LSP ingress.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamEgrLSPOutDefect 1.1.2011.5.12.7.1.2.5
This notification is generated when the LSP is found not in the defect state at the LSP egress.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamEgrLSPInDefect 1.1.2011.5.12.7.1.2.6
This notification is generated when the LSP is found in the defect state at the LSP egress.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamEgrLSPAva 1.1.2011.5.12.7.1.2.7
This notification is generated when the LSP is found in the available state at the LSP egress.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamEgrLSPUnAva 1.1.2011.5.12.7.1.2.8
This notification is generated when the LSP is found in the unavailable state at the LSP egress.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamEgrFirstPkt 1.1.2011.5.12.7.1.2.9
If autoprotocol is enabled, this notification is generated when egress receives the first CV/FFD packet.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamEgrAutoProFDI 1.1.2011.5.12.7.1.2.10
The FDI packet is used by the upstream node in an LSP to inform the egress of the defect information. It is also generated when the auto protocol is enabled, with which the LSP ingress notifies the egress to stop the OAM detection.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamEgrRlsnDown 1.1.2011.5.12.7.1.2.11
This notification is generated when the Rlsn is down.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamL2vcOutDefect 1.1.2011.5.12.7.1.2.12
This notification is generated when the PW is found not in the defect state.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamL2vcInDefect 1.1.2011.5.12.7.1.2.13
This notification is generated when the PW is found not in the defect state.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamL2vcAva 1.1.2011.5.12.7.1.2.14
This notification is generated when the PW is found in the unavailable state.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamL2vcUnAva 1.1.2011.5.12.7.1.2.15
This notification is generated when the PW is found in the unavailable state.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamBidirectionalTunnelOutDefect 1.1.2011.5.12.7.1.2.16
This notification is generated when the CO-ROUTE is found not in the defect state.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamBidirectionalTunnelInDefect 1.1.2011.5.12.7.1.2.17
This notification is generated when the CO-ROUTE is found not in the defect state.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamBidirectionalTunnelAva 1.1.2011.5.12.7.1.2.18
This notification is generated when the CO-ROUTE is found in the unavailable state.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsOamBidirectionalTunnelUnAva 1.1.2011.5.12.7.1.2.19
This notification is generated when the CO-ROUTE is found in the unavailable state.
Status: current Access: read-write
NOTIFICATION-TYPE    

hwMplsPsObjects 1.1.2011.5.12.7.1.3
OBJECT IDENTIFIER    

hwMplsPsTable 1.1.2011.5.12.7.1.3.1
This table specifies per-protection-group MPLS PS capability and associated information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMplsPsEntry

hwMplsPsEntry 1.1.2011.5.12.7.1.3.1.1
An entry in this table is created by an LSR for every protection group capable of supporting mpls ps.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMplsPsEntry  

hwMplsPsIndex 1.1.2011.5.12.7.1.3.1.1.1
This is a unique index for an entry in the mplspsEntry.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

hwMplsPsType 1.1.2011.5.12.7.1.3.1.1.2
The type of protection switch,can be 1:1,1+1,shared mesh, packet 1+1,the default choice is 1:1. In the 1+1 architecture type, a protection LSP is dedicated to each working LSP with the working LSP bridged onto the protection LSP at the source of the protection domain. The traffic on working and protection LSPs is transmitted simultaneously to the sink of the protection domain, where a selection between the working and protection LSP is made, based on some predetermined criteria, such as defect indication. In the 1:1 architecture type, a protection LSP is dedicated to each working LSP. The working traffic is transmitted either by working or protection LSP. In the shared mesh architecture type, possible sharing of protection capacity between disjoint link, node in the network is achieved while guaranteeing recovery from a single failure. In the packet 1+1 architecture type, the traffic is transmitted simultaneously onto two possibly disjoint routed LSPs to the sink of the protection domain. Each pair of duplicate transmitted packets is assigned the same identifier (sequence number) but distinct from the other pairs of duplicate packets. At the sink of the protection domain packet level selection mechanism is employed to select one of the two possibly received copies of each packet. 1: 1:1 protection switching,; 2: 1+1 protection switching; 3: shared mesh protection swiching; 4: packet 1+1 protection switching.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..4  

hwMplsPsWorkTunnName 1.1.2011.5.12.7.1.3.1.1.3
The name of work-tunnel.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hwMplsPsWorkTunnId 1.1.2011.5.12.7.1.3.1.1.4
Work-tunnel id(session-tunnel-id).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

hwMplsPsProtectTunnName 1.1.2011.5.12.7.1.3.1.1.5
The name of protect-tunnel.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

hwMplsPsProtectTunnId 1.1.2011.5.12.7.1.3.1.1.6
Protect-tunnel id(session-tunnel-id).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

hwMplsPsRevertiveMode 1.1.2011.5.12.7.1.3.1.1.7
Revertive mode is a protection switching mode where revertive action (switch back to the working LSP) is taken after the working LSP is repaired.And switching does not occur in a non-revertive mode. 1: revertive; 2: non-revertive;
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hwMplsPsWTR 1.1.2011.5.12.7.1.3.1.1.8
Wait to Restore timer is only applicable for the revertive mode and applies to a working LSP,It prevents reversion back to select the working LSP until the Wait to Restore timer has expired.The default value is 12 minutes.step is 30s.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..60  

hwMplsPsHoldOff 1.1.2011.5.12.7.1.3.1.1.9
The time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm. step is 100ms.maximum is 10s.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..100  

hwMplsPsSwitchCondition 1.1.2011.5.12.7.1.3.1.1.10
The current switch condition of the protection group. 1: clear,This command clears all of the externally initiated switch commands listed below; 2: lockout of protection,Fix the selector position on the working LSP,Prevents the selector from switching to the protection LSP when it is selecting the working LSP. Switches the selector from the protection to the working LSP when it is selecting the protection LSP; 3: forced protection,Switches the selector from the working LSP to the protection LSP (unless a higher priority switch request (i.e., LoP) is in effect); 4: signal fail,for 1:1,Signal Fail (SF) is declared when the source of the protection domain enters the Defect State by receiving a BDI packet (from the return LSP or out of band). 5: manual switch for working-lsp,Switches the selector from the working LSP to the protection LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect); 6: manual switch for protection-lsp,Switches the selector from the protection LSP to the working LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect). 7: WTR-timer; 8: HoldOff-timer; 9: Others; The pripority of the commands are: clear > lockout of protection > force switch > manual switch for working lsp = manual switch for protection lsp
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..9  

hwMplsPsWorkTunnelState 1.1.2011.5.12.7.1.3.1.1.11
The state of working tunnel state in one protection group, whether it is in detection, 1: it is outof defect 2: it enters defect
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hwMplsPsProtTunnelState 1.1.2011.5.12.7.1.3.1.1.12
The state of protection tunnel state in one protection group, whether it is in detection, 1: it is outof defect 2: it enters defect
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hwMplsPsSwitchResult 1.1.2011.5.12.7.1.3.1.1.13
Which tunnel is used to transfer the data stream. 1: working-tunnel 2: protection-tunnel
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hwMplsPsCfgType 1.1.2011.5.12.7.1.3.1.1.14
The type of protection switch which is configured. 1: 1:1 2: 1+1 3: shared mesh 4: packet 1:1
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hwMplsPsCfgProtectTunnId 1.1.2011.5.12.7.1.3.1.1.15
Protect-tunnel id(session-tunnel-id).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..65535  

hwMplsPsCfgRevertiveMode 1.1.2011.5.12.7.1.3.1.1.16
Revertive mode is a protection switching mode where revertive action (switch back to the working LSP) is taken after the working LSP is repaired.And switching does not occur in a non-revertive mode. 1: revertive; 2: non-revertive;
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2  

hwMplsPsCfgWTR 1.1.2011.5.12.7.1.3.1.1.17
Wait to Restore timer is only applicable for the revertive mode and applies to a working LSP,It prevents reversion back to select the working LSP until the Wait to Restore timer has expired.The default value is 12 minutes.step is 30s.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..60  

hwMplsPsCfgHoldOff 1.1.2011.5.12.7.1.3.1.1.18
The time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm. step is 100ms.maximum is 10s.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..100  

hwMplsPsRowStatus 1.1.2011.5.12.7.1.3.1.1.19
This variable is used to create, modify, and delete a row in this table. 1: active 2: not in service 3: not ready 4: create and go 5: create and wait 6: destroy
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwMplsPsLocalState 1.1.2011.5.12.7.1.3.1.1.20
The current local state of the protection group. 0: Lockout of Protection (LO) 1: Signal Fail for Protection (SF-P) 2: Forced Switch (FS) 3: Signal Fail for Working (SF) 4: Signal Degrade for Protection(SD-P) 5: Signal Degrade for Working(SD) 6: Manual Switch (MS) 7: Wait-to-Restore (WTR) 8: Exercise (EXER) 9: Reverse Request(RR) 10: Do Not Revert (DNR) 11: No Request (NR) The pripority of the commands are: LO > SF-P > FS > SF > SD-P > SD > MS > WTR > EXER > RR > DNR > NR
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..11  

hwTunnPsTrapOpen 1.1.2011.5.12.7.1.3.2
1:enable; 2:disable;
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..2  

hwMplsVCPsTable 1.1.2011.5.12.7.1.3.3
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwMplsVCPsEntry

hwMplsApsMismatchReason 1.1.2011.5.12.7.1.3.4
Indicates the alarm reason as below: 1. Bridge type mismatch, one side is 1:1 (Selector Bridge) protection, the other side is 1+1 (Permanent Bridge) protection; 2. Channel type mismatch, one side has APS channel, the other side has no APS channel; 3. Switching type mismatch, one side is bidirectional switching, the other side is unidirectional switching; 4. Operation type mismatch, one side is revertive operation, the other side is non-revertive operation; 5. Traffic request mismatch, one side selects working connection, the other side selects protection connection;
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER bridge(1), channel(2), switching(3), operation(4), traffic(5)  

hwMplsVCPsEntry 1.1.2011.5.12.7.1.3.3.1
this table for these commands 1.mpls te protection tunnel XXX 2. mpls te reverse-lsp { lsp-name XXXX | lsr-id X.X.X.X tunnel-id x } 3. mpls te reserved-for-binding
Status: current Access: not-accessible
OBJECT-TYPE    
  HwMplsVCPsEntry  

hwMplsVCPsIfIndex 1.1.2011.5.12.7.1.3.3.1.1
Description.the index of working tunnel interface of Protection group
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

hwMplsVCPsTNLBinding 1.1.2011.5.12.7.1.3.3.1.2
Description.it is used by command ' mpls te reserved-for-binding '
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

hwMplsTeReverseLspName 1.1.2011.5.12.7.1.3.3.1.3
Description.it is used for command ' mpls te reverse-lsp lspname'
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING  

hwMplsVcPsRowStatus 1.1.2011.5.12.7.1.3.3.1.4
Description. 1: active; 2: notInservice; 3: notReady; 4: CreateAndGo; 5: CreateAndWait; 6: destroy;
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hwMplsTeReverseLspLsrId 1.1.2011.5.12.7.1.3.3.1.5
Description.it is used for command ' mpls te reverse-lsp lsr-id X.X.X.X tunnel-id XX'
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

hwMplsTeReverseLspTunnId 1.1.2011.5.12.7.1.3.3.1.6
Description.it is used for command ' mpls te reverse-lsp lsr-id X.X.X.X tunnel-id XX'
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..65535  

hwMplsPsNotifications 1.1.2011.5.12.7.1.4
OBJECT IDENTIFIER    

hwMplsPsSwitchPtoW 1.1.2011.5.12.7.1.4.1
This notification is generated when switching from protection-lsp to working-lsp occured.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsPsSwitchWtoP 1.1.2011.5.12.7.1.4.2
This notification is generated when switching from woking-lsp to protection-lsp occured.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsApsMismatch 1.1.2011.5.12.7.1.4.3
Trap information indicates fully incompatible provisioning and working/protection configuration mismatch are detected by APS frame.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsApsMismatchRecovery 1.1.2011.5.12.7.1.4.4
Trap information indicates fully incompatible provisioning and working/protection configuration mismatch recovery are detected by APS frame.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsApsLost 1.1.2011.5.12.7.1.4.5
Tunnel protection group did not receive APS frames from protection tunnel.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsApsLostRecovery 1.1.2011.5.12.7.1.4.6
Tunnel protection group received APS frames from protection tunnel.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsApsOutage 1.1.2011.5.12.7.1.4.7
Tunnel protection group changed to defect state.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsApsOutageRecovery 1.1.2011.5.12.7.1.4.8
Tunnel protection group recovered from defect state.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsApsDegraded 1.1.2011.5.12.7.1.4.9
Protection tunnel changed to defect state.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsApsDegradedRecovery 1.1.2011.5.12.7.1.4.10
Protection tunnel recovered from defect state.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsApsSwitchFail 1.1.2011.5.12.7.1.4.11
Tunnel protection group changed to defect state.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsApsSwitchFailRecovery 1.1.2011.5.12.7.1.4.12
Tunnel protection group recovered from defect state.
Status: current Access: read-create
NOTIFICATION-TYPE    

hwMplsOamPsConformance 1.1.2011.5.12.7.1.100
OBJECT IDENTIFIER    

hwMplsOamPsCompliances 1.1.2011.5.12.7.1.100.1
OBJECT IDENTIFIER    

hwMplsOamPsGroupCompliance 1.1.2011.5.12.7.1.100.1.1
The compliance statement for mpls oam ps.
Status: current Access: read-create
MODULE-COMPLIANCE    

hwMplsOamPsGroups 1.1.2011.5.12.7.1.100.2
OBJECT IDENTIFIER    

hwMplsPsGroup 1.1.2011.5.12.7.1.100.2.1
The compliance statement for mpls oam ps management.
Status: current Access: read-create
OBJECT-GROUP    

hwMplsVcPsGroup 1.1.2011.5.12.7.1.100.2.2
The compliance statement for mpls oam ps reverse lsp.
Status: current Access: read-create
OBJECT-GROUP    

hwMplsPsNotificationGroup 1.1.2011.5.12.7.1.100.2.3
Description.
Status: current Access: read-create
NOTIFICATION-GROUP    

hwMplsOamObjectConformance 1.1.2011.5.12.7.1.101
OBJECT IDENTIFIER    

hwMplsOamObjectGroups 1.1.2011.5.12.7.1.101.1
OBJECT IDENTIFIER    

hwMplsOamObjectGroup 1.1.2011.5.12.7.1.101.1.1
The compliance statement for mpls oam all.
Status: current Access: read-create
OBJECT-GROUP    

hwMplsOamNotificationGroup 1.1.2011.5.12.7.1.101.1.2
The compliance statement for mpls oam trap.
Status: current Access: read-create
NOTIFICATION-GROUP    

hwMplsOamObjectCompliances 1.1.2011.5.12.7.1.101.2
OBJECT IDENTIFIER