HiplexAF-MIB

File: HiplexAF-MIB.mib (23473 bytes)

Imported modules

RFC-1215 RFC1155-SMI RFC1213-MIB
RFC-1212

Imported symbols

TRAP-TYPE enterprises DisplayString
OBJECT-TYPE

Defined Types

HiplexAFHostEntry  
SEQUENCE    
  hiplexAFHostName DisplayString
  hiplexAFHostEventId INTEGER
  hiplexAFHostStateInd INTEGER
  hiplexAFHostOperatorRole DisplayString
  hiplexAFHostHomeCatid DisplayString
  hiplexAFHostSystemId INTEGER
  hiplexAFHostBS2Version DisplayString
  hiplexAFHostImcatInd INTEGER
  hiplexAFHostMasterSlaveInd INTEGER
  hiplexAFHostSnmpAgentStateInd INTEGER

HiplexAFSWUEntry  
SEQUENCE    
  hiplexAFSWUName DisplayString
  hiplexAFSWUCreaTime DisplayString
  hiplexAFSWUWorkSystem DisplayString
  hiplexAFSWUVirtHost DisplayString
  hiplexAFSWUVirtHostAct DisplayString
  hiplexAFSWUVirtHostDeact DisplayString
  hiplexAFSWUFEPNumber INTEGER
  hiplexAFSWUPubsetNumber INTEGER
  hiplexAFSWUApplicationNumber INTEGER

HiplexAFSWUHostParamEntry  
SEQUENCE    
  hiplexAFSWUHostParamEventId INTEGER
  hiplexAFSWUHostParamStateInd INTEGER
  hiplexAFSWUHostParamPriority INTEGER
  hiplexAFSWUHostParamOperatorRole DisplayString

HiplexAFSWUHostFEPEntry  
SEQUENCE    
  hiplexAFSWUHostFEPIndex INTEGER
  hiplexAFSWUHostFEPName DisplayString
  hiplexAFSWUHostFEPPortnumber INTEGER

HiplexAFSWUVolumeEntry  
SEQUENCE    
  hiplexAFSWUVolumeName DisplayString
  hiplexAFSWUVolumeTypeName DisplayString
  hiplexAFSWUVolumeType INTEGER
  hiplexAFSWUVolumeImportProc DisplayString
  hiplexAFSWUVolumeExportProc DisplayString

HiplexAFSWUApplicationEntry  
SEQUENCE    
  hiplexAFSWUApplicationMonJVName DisplayString
  hiplexAFSWUApplicationType INTEGER
  hiplexAFSWUApplicationStartProc DisplayString
  hiplexAFSWUApplicationStopProc DisplayString

HiplexAFTrapFilterEntry  
SEQUENCE    
  hiplexAFTrapFilterHost1Name DisplayString
  hiplexAFTrapFilterHost2Name DisplayString
  hiplexAFTrapFilterTrapSendInd INTEGER

Defined Values

sni 1.3.6.1.4.1.231
OBJECT IDENTIFIER    

sniProductMibs 1.3.6.1.4.1.231.2
OBJECT IDENTIFIER    

sniHiplexAF 1.3.6.1.4.1.231.2.35
OBJECT IDENTIFIER    

hiplexAFObjects 1.3.6.1.4.1.231.2.35.1
OBJECT IDENTIFIER    

hiplexAFGlobalData 1.3.6.1.4.1.231.2.35.1.1
OBJECT IDENTIFIER    

hiplexAFHostInfo 1.3.6.1.4.1.231.2.35.1.2
OBJECT IDENTIFIER    

hiplexAFSWUInfo 1.3.6.1.4.1.231.2.35.1.3
OBJECT IDENTIFIER    

hiplexAFSWUHostParamInfo 1.3.6.1.4.1.231.2.35.1.4
OBJECT IDENTIFIER    

hiplexAFSWUHostFEPInfo 1.3.6.1.4.1.231.2.35.1.5
OBJECT IDENTIFIER    

hiplexAFSWUVolumeInfo 1.3.6.1.4.1.231.2.35.1.6
OBJECT IDENTIFIER    

hiplexAFSWUApplicationInfo 1.3.6.1.4.1.231.2.35.1.7
OBJECT IDENTIFIER    

hiplexAFPubsetVolumeInfo 1.3.6.1.4.1.231.2.35.1.8
OBJECT IDENTIFIER    

hiplexAFVersion 1.3.6.1.4.1.231.2.35.1.1.1
Version of Hiplex AF agent
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSPVSUserid 1.3.6.1.4.1.231.2.35.1.1.2
User-Id of Hiplex AF (usually TSOS)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSPVSCatid 1.3.6.1.4.1.231.2.35.1.1.3
Catalog-Id of Shared Pubset containing Jobvariables and Files of Hiplex AF
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

hiplexAFState 1.3.6.1.4.1.231.2.35.1.1.4
State of Hiplex AF: started: at least one main procedure has been started on one host stopped: Hiplex AF is stopped. No Hiplex AF procedure is running on any host undefined: state of Hiplex AF is unkown. Jobvariables with correct value could not be found. State may be set to stopped if it is started.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER started(1), stopped(2), undefined(255)  

hiplexAFTermHost 1.3.6.1.4.1.231.2.35.1.1.5
BCAM Name of the system where termination request for Hiplex AF was started.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFHostTabNum 1.3.6.1.4.1.231.2.35.1.2.1
number of Hosts in the availability cluster
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hiplexAFHostTable 1.3.6.1.4.1.231.2.35.1.2.2
The table of host in the availability cluster
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HiplexAFHostEntry

hiplexAFHostEntry 1.3.6.1.4.1.231.2.35.1.2.2.1
entry for each host
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  HiplexAFHostEntry  

hiplexAFHostName 1.3.6.1.4.1.231.2.35.1.2.2.1.1
BCAM Name of the system
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFHostEventId 1.3.6.1.4.1.231.2.35.1.2.2.1.2
Request Indicator for the main procedure
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-event(1), termination-requested(2), undefined(255)  

hiplexAFHostStateInd 1.3.6.1.4.1.231.2.35.1.2.2.1.3
State of the main procedure. Indicator for partitipation of the host. State may only be set to working if it is terminated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER working(1), terminated(2), undefined(255)  

hiplexAFHostOperatorRole 1.3.6.1.4.1.231.2.35.1.2.2.1.4
Value of parameter Operator-Role of START-XAF command
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

hiplexAFHostHomeCatid 1.3.6.1.4.1.231.2.35.1.2.2.1.5
Home Catalog Id of the system
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFHostSystemId 1.3.6.1.4.1.231.2.35.1.2.2.1.6
SystemId of the system according to the output of the SHOW-SHARED-PUBSET-command
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hiplexAFHostBS2Version 1.3.6.1.4.1.231.2.35.1.2.2.1.7
Version of BS2000 on the system according to the output of the SHOW-SHARED-PUBSET-command
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFHostImcatInd 1.3.6.1.4.1.231.2.35.1.2.2.1.8
Sharer State of the host, according to the output of the SHOW-SHARED-PUBSET-command
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER check(1), crash(2), excat(3), imcat(4), mchange(5), readerr(6), shutdown(7), wrterr(8), undefined(255)  

hiplexAFHostMasterSlaveInd 1.3.6.1.4.1.231.2.35.1.2.2.1.9
Sharer type of the host
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER master(1), backup(2), slave(3), undefined(255)  

hiplexAFHostSnmpAgentStateInd 1.3.6.1.4.1.231.2.35.1.2.2.1.10
State of the SNMP-Subagent. State may be set to not-working if it is working.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER working(1), not-working(2), undefined(255)  

hiplexAFSWUTabNum 1.3.6.1.4.1.231.2.35.1.3.1
number of Switch Units in the availability cluster
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hiplexAFSWUTable 1.3.6.1.4.1.231.2.35.1.3.2
The table of host in the availability cluster
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HiplexAFSWUEntry

hiplexAFSWUEntry 1.3.6.1.4.1.231.2.35.1.3.2.1
entry for each host
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  HiplexAFSWUEntry  

hiplexAFSWUName 1.3.6.1.4.1.231.2.35.1.3.2.1.1
Name of the switch unit
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUCreaTime 1.3.6.1.4.1.231.2.35.1.3.2.1.2
Creation Time of Switch Unit (configuration file)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUWorkSystem 1.3.6.1.4.1.231.2.35.1.3.2.1.3
BCAM Name of the system which presently is work system for this switch unit. Changing the value of this object will start a switch procedure.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUVirtHost 1.3.6.1.4.1.231.2.35.1.3.2.1.4
BCAM Name of the virtual host of the switch unit
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUVirtHostAct 1.3.6.1.4.1.231.2.35.1.3.2.1.5
Name of the procedure for activating the routes to the virtual host
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUVirtHostDeact 1.3.6.1.4.1.231.2.35.1.3.2.1.6
Name of the procedure for deactivating the routes to the virtual host
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUFEPNumber 1.3.6.1.4.1.231.2.35.1.3.2.1.7
Number of front end processors
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hiplexAFSWUPubsetNumber 1.3.6.1.4.1.231.2.35.1.3.2.1.8
Number of non-shared pubsets used by applications of the switch unit
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hiplexAFSWUApplicationNumber 1.3.6.1.4.1.231.2.35.1.3.2.1.9
Number of applications contained in this switch unit
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hiplexAFSWUHostParamTable 1.3.6.1.4.1.231.2.35.1.4.1
The table of host specific Parameters of Switch Units
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HiplexAFSWUHostParamEntry

hiplexAFSWUHostParamEntry 1.3.6.1.4.1.231.2.35.1.4.1.1
entry for each host
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  HiplexAFSWUHostParamEntry  

hiplexAFSWUHostParamEventId 1.3.6.1.4.1.231.2.35.1.4.1.1.1
Last action of the switch unit on the system
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-action(1), pass-over(2), take-over(3), terminate(4), undefined(255)  

hiplexAFSWUHostParamStateInd 1.3.6.1.4.1.231.2.35.1.4.1.1.2
State of the Switch Unit. Value terminated may be changed to work or standby
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER work(1), standby(2), crashed(3), terminated(4), undefined(255)  

hiplexAFSWUHostParamPriority 1.3.6.1.4.1.231.2.35.1.4.1.1.3
Priority of the host in case of an automatic switch
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16  

hiplexAFSWUHostParamOperatorRole 1.3.6.1.4.1.231.2.35.1.4.1.1.4
Value of parameter Operator-Role of START-SWITCH-UNIT command
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUHostFEPTabNum 1.3.6.1.4.1.231.2.35.1.5.1
number of FEP Entries
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..10  

hiplexAFSWUHostFEPTable 1.3.6.1.4.1.231.2.35.1.5.2
The table of parameters of switch units concerning front end processors
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HiplexAFSWUHostFEPEntry

hiplexAFSWUHostFEPEntry 1.3.6.1.4.1.231.2.35.1.5.2.1
Entry describing a relation between a switch units and front end processor
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  HiplexAFSWUHostFEPEntry  

hiplexAFSWUHostFEPIndex 1.3.6.1.4.1.231.2.35.1.5.2.1.1
Index of Front End Processor
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10  

hiplexAFSWUHostFEPName 1.3.6.1.4.1.231.2.35.1.5.2.1.2
BCAM Name of Front End Processor
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUHostFEPPortnumber 1.3.6.1.4.1.231.2.35.1.5.2.1.3
Number of Port used for the System
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

hiplexAFSWUVolumeTabNum 1.3.6.1.4.1.231.2.35.1.6.1
number of data volumes
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hiplexAFSWUVolumeTable 1.3.6.1.4.1.231.2.35.1.6.2
Table of data volumes
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HiplexAFSWUVolumeEntry

hiplexAFSWUVolumeEntry 1.3.6.1.4.1.231.2.35.1.6.2.1
Entry for each data volume
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  HiplexAFSWUVolumeEntry  

hiplexAFSWUVolumeName 1.3.6.1.4.1.231.2.35.1.6.2.1.1
Name of Data Volume
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUVolumeTypeName 1.3.6.1.4.1.231.2.35.1.6.2.1.2
Name of Data Volumetype
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUVolumeType 1.3.6.1.4.1.231.2.35.1.6.2.1.3
Type of data volume
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER shared-pubset(1), pubset(2), private-disk(3), by-user(4), undefined(255)  

hiplexAFSWUVolumeImportProc 1.3.6.1.4.1.231.2.35.1.6.2.1.4
Name of procedure importing data volume
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUVolumeExportProc 1.3.6.1.4.1.231.2.35.1.6.2.1.5
Name of procedure exporting data volume
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUApplicationTabNum 1.3.6.1.4.1.231.2.35.1.7.1
Number of applications
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

hiplexAFSWUApplicationTable 1.3.6.1.4.1.231.2.35.1.7.2
Table of applications
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HiplexAFSWUApplicationEntry

hiplexAFSWUApplicationEntry 1.3.6.1.4.1.231.2.35.1.7.2.1
entry for each application
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  HiplexAFSWUApplicationEntry  

hiplexAFSWUApplicationMonJVName 1.3.6.1.4.1.231.2.35.1.7.2.1.1
Name of jobvariable monitoring application
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUApplicationType 1.3.6.1.4.1.231.2.35.1.7.2.1.2
Application type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER job(1), utm(2), bcam(3), by-user(4), undefined(255)  

hiplexAFSWUApplicationStartProc 1.3.6.1.4.1.231.2.35.1.7.2.1.3
Procedure used to start the application
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFSWUApplicationStopProc 1.3.6.1.4.1.231.2.35.1.7.2.1.4
Procedure used to stop the application
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFTrapFilterTable 1.3.6.1.4.1.231.2.35.1.20
This double-indexed table is a matrix containing an indicator for each pair (host1,host2). A HIPLEX-AF subagent residing on host1 will send traps concerning events of host2 only if the indicator has value yes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HiplexAFTrapFilterEntry

hiplexAFTrapFilterEntry 1.3.6.1.4.1.231.2.35.1.20.1
Entry for each pair (host1,host2)
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  HiplexAFTrapFilterEntry  

hiplexAFTrapFilterHost1Name 1.3.6.1.4.1.231.2.35.1.20.1.1
BCAM Name of the system where HIPLEX-AF subagent is running
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFTrapFilterHost2Name 1.3.6.1.4.1.231.2.35.1.20.1.2
BCAM Name of the system in the HIPLEX-AF cluster.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hiplexAFTrapFilterTrapSendInd 1.3.6.1.4.1.231.2.35.1.20.1.3
yes: traps will be sent. no: no traps will be sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2), undefined(255)  

hiplexAFTraps 1.3.6.1.4.1.231.2.35.2
OBJECT IDENTIFIER    

hiplexAFStart 301
Hiplex AF main procedure has been started.
TRAP-TYPE    

hiplexAFSWUStart 302
Switch unit procedure has been started.
TRAP-TYPE    

hiplexAFStop 303
Termination of Hiplex AF has been started.
TRAP-TYPE    

hiplexAFCrash 304
A system has been terminated abnormally.
TRAP-TYPE    

hiplexAFSWUAppStop 305
The applications of a switch unit will be stopped.
TRAP-TYPE    

hiplexAFSWUAppStart 306
The applications of a switch unit will be started.
TRAP-TYPE    

hiplexAFSWUStop 307
Switch unit procedure has been stopped.
TRAP-TYPE