IBM-RXR-MIB

File: IBM-RXR-MIB.mib (97154 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC-1213

Imported symbols

Counter Gauge TimeTicks
enterprises OBJECT-TYPE TRAP-TYPE
PhysAddress

Defined Types

MacAddress  
OCTET STRING Size(6)    

BridgeId  
OCTET STRING Size(8)    

Timeout  
INTEGER    

Rxr1dBasePortEntry  
SEQUENCE    
  rxr1dBasePort INTEGER
  rxr1dBasePortIfIndex INTEGER
  rxr1dBasePortCircuit OBJECT IDENTIFIER
  rxr1dBasePortDelayExceededDiscards Counter
  rxr1dBasePortMtuExceededDiscards Counter

Rxr1dStpPortEntry  
SEQUENCE    
  rxr1dStpPort INTEGER
  rxr1dStpPortPriority INTEGER
  rxr1dStpPortState INTEGER
  rxr1dStpPortEnable INTEGER
  rxr1dStpPortPathCost INTEGER
  rxr1dStpPortDesignatedRoot BridgeId
  rxr1dStpPortDesignatedCost INTEGER
  rxr1dStpPortDesignatedBridge BridgeId
  rxr1dStpPortDesignatedPort OCTET STRING
  rxr1dStpPortForwardTransitions Counter

Rxr1dSrPortEntry  
SEQUENCE    
  rxr1dSrPort INTEGER
  rxr1dSrPortHopCount INTEGER
  rxr1dSrPortLocalSegment INTEGER
  rxr1dSrPortBridgeNum INTEGER
  rxr1dSrPortTargetSegment INTEGER
  rxr1dSrPortLargestFrame INTEGER
  rxr1dSrPortSTESpanMode INTEGER
  rxr1dSrPortSpecInFrames Counter
  rxr1dSrPortSpecOutFrames Counter
  rxr1dSrPortApeInFrames Counter
  rxr1dSrPortApeOutFrames Counter
  rxr1dSrPortSteInFrames Counter
  rxr1dSrPortSteOutFrames Counter
  rxr1dSrPortSegmentMismatchDiscards Counter
  rxr1dSrPortDuplicateSegmentDiscards Counter
  rxr1dSrPortHopCountExceededDiscards Counter

Rxr1dTpFdbEntry  
SEQUENCE    
  rxr1dTpFdbAddress MacAddress
  rxr1dTpFdbPort INTEGER
  rxr1dTpFdbStatus INTEGER

Rxr1dTpPortEntry  
SEQUENCE    
  rxr1dTpPort INTEGER
  rxr1dTpPortMaxInfo INTEGER
  rxr1dTpPortInFrames Counter
  rxr1dTpPortOutFrames Counter
  rxr1dTpPortInDiscards Counter

Rxr1dStaticEntry  
SEQUENCE    
  rxr1dStaticAddress MacAddress
  rxr1dStaticReceivePort INTEGER
  rxr1dStaticAllowedToGoTo OCTET STRING
  rxr1dStaticStatus INTEGER

NetNumber  
OCTET STRING Size(4)    

IPXSysEntry  
SEQUENCE    
  ipxSysInstance INTEGER
  ipxSysExistState INTEGER
  ipxSysIntNetNumExists INTEGER
  ipxSysIntNetNum NetNumber
  ipxSysName OCTET STRING
  ipxSysMaxPathSplits INTEGER
  ipxSysMaxHops INTEGER
  ipxSysVersionMajor INTEGER
  ipxSysVersionMinor INTEGER
  ipxSysInReceives Counter
  ipxSysInTooManyHops Counter
  ipxSysInHdrErrors Counter
  ipxSysInUnknownSockets Counter
  ipxSysInFiltered Counter
  ipxSysInCompressDiscards Counter
  ipxSysInDiscards Counter
  ipxSysInDelivers Counter
  ipxSysNETBIOSPackets Counter
  ipxSysForwPackets Counter
  ipxSysOutRequests Counter
  ipxSysOutNoRoutes Counter
  ipxSysOutFiltered Counter
  ipxSysOutCompressDiscards Counter
  ipxSysOutMalformedRequests Counter
  ipxSysOutDiscards Counter
  ipxSysOutPackets Counter
  ipxSysCircCount Counter
  ipxSysDestCount Counter
  ipxSysServCount Counter
  ipxSysResourceFailures Counter
  ipxSysConfigSockets Counter
  ipxSysMaxOpenSockets Counter
  ipxSysOpenSocketFails Counter

IPXCircEntry  
SEQUENCE    
  ipxCircSysInstance INTEGER
  ipxCircIndex INTEGER
  ipxCircExistState INTEGER
  ipxCircOperState INTEGER
  ipxCircIfIndex NetNumber
  ipxCircName OCTET STRING
  ipxCircInfo OCTET STRING
  ipxCircType INTEGER
  ipxCircLocalMaxPacketSize INTEGER
  ipxCircCompressState INTEGER
  ipxCircCompressSlots INTEGER
  ipxCircCompressedSent INTEGER
  ipxCircUncompressedSent INTEGER
  ipxCircMediaType INTEGER
  ipxCircNetNumber NetNumber
  ipxCircStateChanges Counter
  ipxCircInitFails Counter
  ipxCircDelay INTEGER
  ipxCircThroughput INTEGER

IPXDestEntry  
SEQUENCE    
  ipxDestSysInstance INTEGER
  ipxDestNetNum NetNumber
  ipxDestProtocol INTEGER
  ipxDestCost INTEGER
  ipxDestHopCount INTEGER
  ipxDestNextHopCircIndex INTEGER
  ipxDestNextHopNICAddress OCTET STRING
  ipxDestNextHopNetNum NetNumber
  ipxDestType INTEGER

IPXServEntry  
SEQUENCE    
  ipxServSysInstance INTEGER
  ipxServName OCTET STRING
  ipxServTypeValue OCTET STRING
  ipxServType INTEGER
  ipxServProtocol INTEGER
  ipxServNetNum NetNumber
  ipxServNode OCTET STRING
  ipxServSocket OCTET STRING

IPXDestServEntry  
SEQUENCE    
  ipxDestServSysInstance INTEGER
  ipxDestServNetNum NetNumber
  ipxDestServNode OCTET STRING
  ipxDestServSocket OCTET STRING
  ipxDestServName OCTET STRING
  ipxDestServTypeValue OCTET STRING
  ipxDestServType INTEGER
  ipxDestServProtocol INTEGER

NetNumber  
OCTET STRING Size(4)    

RIPSAPSysEntry  
SEQUENCE    
  ripsapSysInstance INTEGER
  ripsapSysRIPState INTEGER
  ripsapSysRIPIncorrectPackets Counter
  ripsapSysSAPState INTEGER
  ripsapSysSAPIncorrectPackets Counter

RIPSAPCircEntry  
SEQUENCE    
  ripsapCircSysInstance INTEGER
  ripsapCircIndex INTEGER
  ripsapCircRIPState INTEGER
  ripsapCircRIPPace INTEGER
  ripsapCircRIPUpdate INTEGER
  ripsapCircRIPAgeMultiplier INTEGER
  ripsapCircRIPPacketSize INTEGER
  ripsapCircRIPOutPackets Counter
  ripsapCircRIPInPackets Counter
  ripsapCircSAPState INTEGER
  ripsapCircSAPPace INTEGER
  ripsapCircSAPUpdate INTEGER
  ripsapCircSAPAgeMultiplier INTEGER
  ripsapCircSAPGetNearestServerReply INTEGER
  ripsapCircSAPPacketSize INTEGER
  ripsapCircSAPOutPackets Counter
  ripsapCircSAPInPackets Counter

Defined Values

ibm 1.3.6.1.4.1.2
OBJECT IDENTIFIER    

ibmProd 1.3.6.1.4.1.2.6
OBJECT IDENTIFIER    

routeXpander 1.3.6.1.4.1.2.6.26
OBJECT IDENTIFIER    

rxr1dBridge 1.3.6.1.4.1.2.6.26.1
OBJECT IDENTIFIER    

rxr1dBase 1.3.6.1.4.1.2.6.26.1.1
OBJECT IDENTIFIER    

rxr1dStp 1.3.6.1.4.1.2.6.26.1.2
OBJECT IDENTIFIER    

rxr1dSr 1.3.6.1.4.1.2.6.26.1.3
OBJECT IDENTIFIER    

rxr1dTp 1.3.6.1.4.1.2.6.26.1.4
OBJECT IDENTIFIER    

rxr1dStatic 1.3.6.1.4.1.2.6.26.1.5
OBJECT IDENTIFIER    

rxr1dBaseBridgeAddress 1.3.6.1.4.1.2.6.26.1.1.1
The MAC address used by this bridge when it must be referred to in a unique fashion. It is recommended that this be the numerically smallest MAC address of all ports that belong to this bridge. However it is only required to be unique. When concatenated with rxr1dStpPriority a unique BridgeIdentifier is formed which is used in the Spanning Tree Protocol.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

rxr1dBaseNumPorts 1.3.6.1.4.1.2.6.26.1.1.2
The number of ports controlled by this bridging entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxr1dBaseType 1.3.6.1.4.1.2.6.26.1.1.3
Indicates what type of bridging this bridge can perform. If a bridge is actually performing a certain type of bridging this will be indicated by entries in the port table for the given type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), transparent-only(2), sourceroute-only(3), srt(4)  

rxr1dBasePortTable 1.3.6.1.4.1.2.6.26.1.1.4
A table that contains generic information about every port that is associated with this bridge. Transparent, source-route, and srt ports are included.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Rxr1dBasePortEntry

rxr1dBasePortEntry 1.3.6.1.4.1.2.6.26.1.1.4.1
A list of information for each port of the bridge.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Rxr1dBasePortEntry  

rxr1dBasePort 1.3.6.1.4.1.2.6.26.1.1.4.1.1
The port number of the port for which this entry contains bridge management information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxr1dBasePortIfIndex 1.3.6.1.4.1.2.6.26.1.1.4.1.2
The value of the instance of the ifIndex object, defined in [4,6], for the interface corresponding to this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxr1dBasePortCircuit 1.3.6.1.4.1.2.6.26.1.1.4.1.3
For a port which (potentially) has the same value of rxr1dBasePortIfIndex as another port on the same bridge, this object contains the name of an object instance unique to this port. For example, in the case where multiple ports correspond one- to-one with multiple X.25 virtual circuits, this value might identify an (e.g., the first) object instance associated with the X.25 virtual circuit corresponding to this port. For a port which has a unique value of rxr1dBasePortIfIndex, this object can have the value { 0 0 }.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

rxr1dBasePortDelayExceededDiscards 1.3.6.1.4.1.2.6.26.1.1.4.1.4
The number of frames discarded by this port due to excessive transit delay through the bridge. It is incremented by both transparent and source route bridges.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dBasePortMtuExceededDiscards 1.3.6.1.4.1.2.6.26.1.1.4.1.5
The number of frames discarded by this port due to an excessive size. It is incremented by both transparent and source route bridges.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dStpProtocolSpecification 1.3.6.1.4.1.2.6.26.1.2.1
An indication of what version of the Spanning Tree Protocol is being run. The value 'decLb100(2)' indicates the DEC LANbridge 100 Spanning Tree protocol. IEEE 802.1d implementations will return 'ieee8021d(3)'. If future versions of the IEEE Spanning Tree Protocol are released that are incompatible with the current version a new value will be defined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), decLb100(2), ieee8021d(3)  

rxr1dStpPriority 1.3.6.1.4.1.2.6.26.1.2.2
The value of the write-able portion of the Bridge ID, i.e., the first two octets of the (8 octet long) Bridge ID. The other (last) 6 octets of the Bridge ID are given by the value of rxr1dBaseBridgeAddress.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

rxr1dStpTimeSinceTopologyChange 1.3.6.1.4.1.2.6.26.1.2.3
The time (in hundredths of a second) since the last time a topology change was detected by the bridge entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

rxr1dStpTopChanges 1.3.6.1.4.1.2.6.26.1.2.4
The total number of topology changes detected by this bridge since the management entity was last reset or initialized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dStpDesignatedRoot 1.3.6.1.4.1.2.6.26.1.2.5
The bridge identifier of the root of the spanning tree as determined by the Spanning Tree Protocol as executed by this node. This value is used as the Root Identifier parameter in all Configuration Bridge PDUs originated by this node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  BridgeId  

rxr1dStpRootCost 1.3.6.1.4.1.2.6.26.1.2.6
The cost of the path to the root as seen from this bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxr1dStpRootPort 1.3.6.1.4.1.2.6.26.1.2.7
The port number of the port which offers the lowest cost path from this bridge to the root bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxr1dStpMaxAge 1.3.6.1.4.1.2.6.26.1.2.8
The maximum age of Spanning Tree Protocol information learned from the network on any port before it is discarded, in units of hundredths of a second. This is the actual value that this bridge is currently using.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Timeout  

rxr1dStpHelloTime 1.3.6.1.4.1.2.6.26.1.2.9
The amount of time between the transmission of Configuration bridge PDUs by this node on any port when it is the root of the spanning tree or trying to become so, in units of hundredths of a second. This is the actual value that this bridge is currently using.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Timeout  

rxr1dStpHoldTime 1.3.6.1.4.1.2.6.26.1.2.10
This time value determines the interval length during which no more than two Configuration bridge PDUs shall be transmitted by this node, in units of hundredths of a second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxr1dStpForwardDelay 1.3.6.1.4.1.2.6.26.1.2.11
This time value, measured in units of hundredths of a second, controls how fast a port changes its spanning state when moving towards the Forwarding state. The value determines how long the port stays in a particular state before moving to the next state. For example, how long a port stays in the Listening state when moving from Blocking to Learning. This value is also used, when a topology change has been detected and is underway, to age all dynamic entries in the Forwarding Database. [Note that this value is the one that this bridge is currently using, in contrast to rxr1dStpBridgeForwardDelay which is the value that this bridge and all others would start using if/when this bridge were to become the root.]
Status: mandatory Access: read-only
OBJECT-TYPE    
  Timeout  

rxr1dStpBridgeMaxAge 1.3.6.1.4.1.2.6.26.1.2.12
The value that all bridges use for MaxAge when this bridge is acting as the root. Note that 802.1d/D9 specifies that the range for this parameter is related to the value of rxr1dStpBridgeHelloTime. The granularity of this timer is specified by 802.1d/D9 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Timeout 600..4000  

rxr1dStpBridgeHelloTime 1.3.6.1.4.1.2.6.26.1.2.13
The value that all bridges use for HelloTime when this bridge is acting as the root. The granularity of this timer is specified by 802.1d/D9 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Timeout 100..1000  

rxr1dStpBridgeForwardDelay 1.3.6.1.4.1.2.6.26.1.2.14
The value that all bridges use for ForwardDelay when this bridge is acting as the root. Note that 802.1d/D9 specifies that the range for this parameter is related to the value of rxr1dStpBridgeMaxAge. The granularity of this timer is specified by 802.1d/D9 to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Timeout 400..3000  

rxr1dStpPortTable 1.3.6.1.4.1.2.6.26.1.2.15
A table that contains port-specific information for the Spanning Tree Protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Rxr1dStpPortEntry

rxr1dStpPortEntry 1.3.6.1.4.1.2.6.26.1.2.15.1
A list of information maintained by every port about the Spanning Tree Protocol state for that port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Rxr1dStpPortEntry  

rxr1dStpPort 1.3.6.1.4.1.2.6.26.1.2.15.1.1
The port number of the port for which this entry contains Spanning Tree Protocol management information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxr1dStpPortPriority 1.3.6.1.4.1.2.6.26.1.2.15.1.2
The value of the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID. The other octet of the Port ID is given by the value of rxr1dStpPort.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

rxr1dStpPortState 1.3.6.1.4.1.2.6.26.1.2.15.1.3
The port's current state as defined by application of the Spanning Tree Protocol. This state controls what action a port takes on reception of a frame. If the bridge has detected a port that is malfunctioning it will place that port into the broken(6) state. For ports which are disabled (see rxr1dStpPortEnable), this object will have a value of disabled(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), blocking(2), listening(3), learning(4), forwarding(5), broken(6)  

rxr1dStpPortEnable 1.3.6.1.4.1.2.6.26.1.2.15.1.4
The enabled/disabled status of the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

rxr1dStpPortPathCost 1.3.6.1.4.1.2.6.26.1.2.15.1.5
The contribution of this port to the path cost of paths towards the spanning tree root which include this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

rxr1dStpPortDesignatedRoot 1.3.6.1.4.1.2.6.26.1.2.15.1.6
The unique Bridge Identifier of the Bridge recorded as the Root in the Configuration BPDUs transmitted by the Designated Bridge for the segment to which the port is attached.
Status: mandatory Access: read-only
OBJECT-TYPE    
  BridgeId  

rxr1dStpPortDesignatedCost 1.3.6.1.4.1.2.6.26.1.2.15.1.7
The path cost of the Designated Port of the segment connected to this port. This value is compared to the Root Path Cost field in received bridge PDUs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxr1dStpPortDesignatedBridge 1.3.6.1.4.1.2.6.26.1.2.15.1.8
The Bridge Identifier of the bridge which this port considers to be the Designated Bridge for this port's segment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  BridgeId  

rxr1dStpPortDesignatedPort 1.3.6.1.4.1.2.6.26.1.2.15.1.9
The Port Identifier of the port on the Designated Bridge for this port's segment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

rxr1dStpPortForwardTransitions 1.3.6.1.4.1.2.6.26.1.2.15.1.10
The number of times this port has transitioned from the Learning state to the Forwarding state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dSrPortTable 1.3.6.1.4.1.2.6.26.1.3.1
A table that contains information about every port that is associated with this source route bridge.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Rxr1dSrPortEntry

rxr1dSrPortEntry 1.3.6.1.4.1.2.6.26.1.3.1.1
A list of information for each port of a source route bridge.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Rxr1dSrPortEntry  

rxr1dSrPort 1.3.6.1.4.1.2.6.26.1.3.1.1.1
The port number of the port for which this entry contains Source Route management information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxr1dSrPortHopCount 1.3.6.1.4.1.2.6.26.1.3.1.1.2
The maximum number of routing descriptors allowed in an All Paths or Spanning Tree Explorer frames.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rxr1dSrPortLocalSegment 1.3.6.1.4.1.2.6.26.1.3.1.1.3
The segment number that uniquely identifies the segment to which this port is connected. Current source routing protocols limit this value to the range: 0 through 4095. A value of 65535 signifies that no segment number is assigned to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rxr1dSrPortBridgeNum 1.3.6.1.4.1.2.6.26.1.3.1.1.4
A bridge number uniquely identifies a bridge when more than one bridge is used to span the same two segments. Current source routing protocols limit this value to the range: 0 through 15. A value of 65535 signifies that no bridge number is assigned to this bridge.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rxr1dSrPortTargetSegment 1.3.6.1.4.1.2.6.26.1.3.1.1.5
The segment number that corresponds to the target segment this port is considered to be connected to by the bridge. Current source routing protocols limit this value to the range: 0 through 4095. A value of 65535 signifies that no target segment is assigned to this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rxr1dSrPortLargestFrame 1.3.6.1.4.1.2.6.26.1.3.1.1.6
The maximum size of the INFO field (LLC and above) that this port can send/receive. It does not include any MAC level (framing) octets. The value of this object is used by this bridge to determine whether a modification of the LargestFrame (LF, see [14]) field of the Routing Control field of the Routing Information Field is necessary. Valid values as defined by the 802.5 source routing bridging specification[14] are 516, 1500, 2052, 4472, 8144, 11407, 17800, and 65535 octets. Behavior of the port when an illegal value is written is implementation specific. It is recommended that a reasonable legal value be chosen.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER rxr1dSrMtu516(516), rxr1dSrMtu1500(1500), rxr1dSrMtu2052(2052), rxr1dSrMtu4472(4472), rxr1dSrMtu8144(8144), rxr1dSrMtu11407(11407), rxr1dSrMtu17800(17800), rxr1dSrMtu65535(65535)  

rxr1dSrPortSTESpanMode 1.3.6.1.4.1.2.6.26.1.3.1.1.7
Determines how this port behaves when presented with a Spanning Tree Explorer frame. The value 'disabled(2)' indicates that the port will not accept or send Spanning Tree Explorer packets; any STE packets received will be silently discarded. The value 'forced(3)' indicates the port will always accept and propagate Spanning Tree Explorer frames. This allows a manually configured Spanning Tree for this class of packet to be configured. Note that unlike transparent bridging this is not catastrophic to the network if there are loops. The value 'auto-span(1)' can only be returned by a bridge that both implements the Spanning Tree Protocol and has use of the protocol enabled on this port. The behavior of the port for Spanning Tree Explorer frames is determined by the state of rxr1dStpPortState. If the port is in the 'forwarding' state, the frame will be accepted or propagated. Otherwise it will be silently discarded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto-span(1), disabled(2), forced(3)  

rxr1dSrPortSpecInFrames 1.3.6.1.4.1.2.6.26.1.3.1.1.8
The number of specifically routed frames that have been received from this port's segment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dSrPortSpecOutFrames 1.3.6.1.4.1.2.6.26.1.3.1.1.9
The number of specifically routed frames that this port has transmitted on its segment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dSrPortApeInFrames 1.3.6.1.4.1.2.6.26.1.3.1.1.10
The number of all paths explorer frames that have been received by this port from its segment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dSrPortApeOutFrames 1.3.6.1.4.1.2.6.26.1.3.1.1.11
The number of all paths explorer frames that have been transmitted by this port on its segment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dSrPortSteInFrames 1.3.6.1.4.1.2.6.26.1.3.1.1.12
The number of spanning tree explorer frames that have been received by this port from its segment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dSrPortSteOutFrames 1.3.6.1.4.1.2.6.26.1.3.1.1.13
The number of spanning tree explorer frames that have been transmitted by this port on its segment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dSrPortSegmentMismatchDiscards 1.3.6.1.4.1.2.6.26.1.3.1.1.14
The number of explorer frames that have been discarded by this port because the routing descriptor field contained an invalid adjacent segment value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dSrPortDuplicateSegmentDiscards 1.3.6.1.4.1.2.6.26.1.3.1.1.15
The number of frames that have been discarded by this port because the routing descriptor field contained a duplicate segment identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dSrPortHopCountExceededDiscards 1.3.6.1.4.1.2.6.26.1.3.1.1.16
The number of explorer frames that have been discarded by this port because the Routing Information Field has exceeded the maximum route descriptor length.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dTpLearnedEntryDiscards 1.3.6.1.4.1.2.6.26.1.4.1
The total number of Forwarding Database entries, which have been or would have been learnt, but have been discarded due to a lack of space to store them in the Forwarding Database. If this counter is increasing, it indicates that the Forwarding Database is regularly becoming full (a condition which has unpleasant performance effects on the subnetwork). If this counter has a significant value but is not presently increasing, it indicates that the problem has been occurring but is not persistent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dTpAgingTime 1.3.6.1.4.1.2.6.26.1.4.2
The timeout period in seconds for aging out dynamically learned forwarding information.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rxr1dTpFdbTable 1.3.6.1.4.1.2.6.26.1.4.3
A table that contains information about unicast entries for which the bridge has forwarding and/or filtering information. This information is used by the transparent bridging function in determining how to propagate a received frame.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Rxr1dTpFdbEntry

rxr1dTpFdbEntry 1.3.6.1.4.1.2.6.26.1.4.3.1
Information about a specific unicast MAC address for which the bridge has some forwarding and/or filtering information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Rxr1dTpFdbEntry  

rxr1dTpFdbAddress 1.3.6.1.4.1.2.6.26.1.4.3.1.1
A unicast MAC address for which the bridge has forwarding and/or filtering information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

rxr1dTpFdbPort 1.3.6.1.4.1.2.6.26.1.4.3.1.2
Either the value '0', or the port number of the port on which a frame having a source address equal to the value of the corresponding instance of rxr1dTpFdbAddress has been seen. A value of '0' indicates that the port number has not been learned but that the bridge does have some forwarding/filtering information about this address (e.g. in the rxr1dStaticTable). Implementors are encouraged to assign the port value to this object whenever it is learned even for addresses for which the corresponding value of rxr1dTpFdbStatus is not learned(3).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxr1dTpFdbStatus 1.3.6.1.4.1.2.6.26.1.4.3.1.3
The status of this entry. The meanings of the values are: other(1) : none of the following. This would include the case where some other MIB object (not the corresponding instance of rxr1dTpFdbPort, nor an entry in the rxr1dStaticTable) is being used to determine if and how frames addressed to the value of the corresponding instance of rxr1dTpFdbAddress are being forwarded. invalid(2) : this entry is not longer valid (e.g., it was learned but has since aged-out), but has not yet been flushed from the table. learned(3) : the value of the corresponding instance of rxr1dTpFdbPort was learned, and is being used. self(4) : the value of the corresponding instance of rxr1dTpFdbAddress represents one of the bridge's addresses. The corresponding instance of rxr1dTpFdbPort indicates which of the bridge's ports has this address. mgmt(5) : the value of the corresponding instance of rxr1dTpFdbAddress is also the value of an existing instance of rxr1dStaticAddress.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), invalid(2), learned(3), self(4), mgmt(5)  

rxr1dTpPortTable 1.3.6.1.4.1.2.6.26.1.4.4
A table that contains information about every port that is associated with this transparent bridge.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Rxr1dTpPortEntry

rxr1dTpPortEntry 1.3.6.1.4.1.2.6.26.1.4.4.1
A list of information for each port of a transparent bridge.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Rxr1dTpPortEntry  

rxr1dTpPort 1.3.6.1.4.1.2.6.26.1.4.4.1.1
The port number of the port for which this entry contains Transparent bridging management information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxr1dTpPortMaxInfo 1.3.6.1.4.1.2.6.26.1.4.4.1.2
The maximum size of the INFO (non-MAC) field that this port will receive or transmit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rxr1dTpPortInFrames 1.3.6.1.4.1.2.6.26.1.4.4.1.3
The number of frames that have been received by this port from its segment. Note that a frame received on the interface corresponding to this port is only counted by this object if and only if it is for a protocol being processed by the local bridging function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dTpPortOutFrames 1.3.6.1.4.1.2.6.26.1.4.4.1.4
The number of frames that have been transmitted by this port to its segment. Note that a frame transmitted on the interface corresponding to this port is only counted by this object if and only if it is for a protocol being processed by the local bridging function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dTpPortInDiscards 1.3.6.1.4.1.2.6.26.1.4.4.1.5
Count of valid frames received which were discarded (i.e., filtered) by the Forwarding Process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rxr1dStaticTable 1.3.6.1.4.1.2.6.26.1.5.1
A table containing filtering information configured into the bridge by (local or network) management specifying the set of ports to which frames received from specific ports and containing specific destination addresses are allowed to be forwarded. The value of zero in this table as the port number from which frames with a specific destination address are received, is used to specify all ports for which there is no specific entry in this table for that particular destination address. Entries are valid for unicast and for group/broadcast addresses.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Rxr1dStaticEntry

rxr1dStaticEntry 1.3.6.1.4.1.2.6.26.1.5.1.1
Filtering information configured into the bridge by (local or network) management specifying the set of ports to which frames received from a specific port and containing a specific destination address are allowed to be forwarded.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Rxr1dStaticEntry  

rxr1dStaticAddress 1.3.6.1.4.1.2.6.26.1.5.1.1.1
The destination MAC address in a frame to which this entry's filtering information applies. This object can take the value of a unicast address, a group address or the broadcast address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  MacAddress  

rxr1dStaticReceivePort 1.3.6.1.4.1.2.6.26.1.5.1.1.2
Either the value '0', or the port number of the port from which a frame must be received in order for this entry's filtering information to apply. A value of zero indicates that this entry applies on all ports of the bridge for which there is no other applicable entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rxr1dStaticAllowedToGoTo 1.3.6.1.4.1.2.6.26.1.5.1.1.3
The set of ports to which frames received from a specific port and destined for a specific MAC address, are allowed to be forwarded. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the bridge is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'. (Note that the setting of the bit corresponding to the port from which a frame is received is irrelevant.)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

rxr1dStaticStatus 1.3.6.1.4.1.2.6.26.1.5.1.1.4
This object indicates the status of this entry. other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. invalid(2) - writing this value to the object removes the corresponding entry. permanent(3) - this entry is currently in use and will remain so after the next reset of the bridge. deleteOnReset(4) - this entry is currently in use and will remain so until the next reset of the bridge. deleteOnTimeout(5) - this entry is currently in use and will remain so until it is aged out.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), invalid(2), permanent(3), deleteOnReset(4), deleteOnTimeout(5)  

newRoot 1
The newRoot trap indicates that the sending agent has become the new root of the Spanning Tree; the trap is sent by a bridge soon after its election as the new root, e.g., upon expiration of the Topology Change Timer immediately subsequent to its election.
TRAP-TYPE    

topologyChange 2
A topologyChange trap is sent by a bridge when any of its configured ports transitions from the Learning state to the Forwarding state, or from the Forwarding state to the Blocking state. The trap is not sent if a newRoot trap is sent for the same transition.
TRAP-TYPE    

rxripxRouter 1.3.6.1.4.1.2.6.26.2
OBJECT IDENTIFIER    

ipx 1.3.6.1.4.1.2.6.26.2.1
OBJECT IDENTIFIER    

ipxSystem 1.3.6.1.4.1.2.6.26.2.1.1
OBJECT IDENTIFIER    

ipxCircuit 1.3.6.1.4.1.2.6.26.2.1.2
OBJECT IDENTIFIER    

ipxForwarding 1.3.6.1.4.1.2.6.26.2.1.3
OBJECT IDENTIFIER    

ipxServices 1.3.6.1.4.1.2.6.26.2.1.4
OBJECT IDENTIFIER    

ipxSysTable 1.3.6.1.4.1.2.6.26.2.1.1.1
The IPX System table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IPXSysEntry

ipxSysEntry 1.3.6.1.4.1.2.6.26.2.1.1.1.1
Each entry corresponds to one instance of IPX running on the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IPXSysEntry  

ipxSysInstance 1.3.6.1.4.1.2.6.26.2.1.1.1.1.1
The unique identifier of the instance of IPX to which this row corresponds. This value may be written only when creating a new entry in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxSysExistState 1.3.6.1.4.1.2.6.26.2.1.1.1.1.2
The validity of this entry in the IPX system table. Setting this field to off indicates that this entry may be deleted from the system table at the IPX implemntation's discretion.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ipxSysIntNetNumExists 1.3.6.1.4.1.2.6.26.2.1.1.1.1.3
Indicates whether this instance of IPX has an internal network number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ipxSysIntNetNum 1.3.6.1.4.1.2.6.26.2.1.1.1.1.4
The IPX internal network number of this instance of IPX. This value is undefined if the value of ipxSysIntNetNumExists is no.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NetNumber  

ipxSysName 1.3.6.1.4.1.2.6.26.2.1.1.1.1.5
The readable name for this system.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..48)  

ipxSysMaxPathSplits 1.3.6.1.4.1.2.6.26.2.1.1.1.1.6
The maximum number of paths with equal routing metric value which this instance of IPX may split between when forwarding packets.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxSysMaxHops 1.3.6.1.4.1.2.6.26.2.1.1.1.1.7
The maximum number of hops a packet may take.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxSysVersionMajor 1.3.6.1.4.1.2.6.26.2.1.1.1.1.8
The major version of IPX supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ipxSysVersionMinor 1.3.6.1.4.1.2.6.26.2.1.1.1.1.9
The minor version of IPX supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ipxSysInReceives 1.3.6.1.4.1.2.6.26.2.1.1.1.1.10
The total number of IPX packets received, including those received in error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysInTooManyHops 1.3.6.1.4.1.2.6.26.2.1.1.1.1.11
The number of IPX packets discarded due to exceeding the maximum hop count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysInHdrErrors 1.3.6.1.4.1.2.6.26.2.1.1.1.1.12
The number of IPX packets discarded due to errors in their headers, including ant IPX packet with a size less than the minimum of 30 bytes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysInUnknownSockets 1.3.6.1.4.1.2.6.26.2.1.1.1.1.13
The number of IPX packets discarded because the destination socket was not open.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysInFiltered 1.3.6.1.4.1.2.6.26.2.1.1.1.1.14
The number of incoming IPX packets discarded due to filtering.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysInCompressDiscards 1.3.6.1.4.1.2.6.26.2.1.1.1.1.15
The number of incoming IPX packets discarded due to decompression errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysInDiscards 1.3.6.1.4.1.2.6.26.2.1.1.1.1.16
The number of IPX packets received but discarded due to processing decision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysInDelivers 1.3.6.1.4.1.2.6.26.2.1.1.1.1.17
The total number of IPX packets delivered locally, including packets from local applications.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysNETBIOSPackets 1.3.6.1.4.1.2.6.26.2.1.1.1.1.18
The total number of NetBIOS packets received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysForwPackets 1.3.6.1.4.1.2.6.26.2.1.1.1.1.19
The number of IPX packets forwarded.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysOutRequests 1.3.6.1.4.1.2.6.26.2.1.1.1.1.20
The number of IPX packets supplied locally for transmission, not including any packets counted in ipxForwPackets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysOutNoRoutes 1.3.6.1.4.1.2.6.26.2.1.1.1.1.21
The number of IPX packets discarded because no route was found.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysOutFiltered 1.3.6.1.4.1.2.6.26.2.1.1.1.1.22
The number of outgoing IPX packets discarded due to filtering.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysOutCompressDiscards 1.3.6.1.4.1.2.6.26.2.1.1.1.1.23
The number of outgoing IPX packets discarded due to compression errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysOutMalformedRequests 1.3.6.1.4.1.2.6.26.2.1.1.1.1.24
The number of IPX packets supplied locally that contained errors in their structure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysOutDiscards 1.3.6.1.4.1.2.6.26.2.1.1.1.1.25
The number of outgoing IPX packets discarded due to processing decision.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysOutPackets 1.3.6.1.4.1.2.6.26.2.1.1.1.1.26
The total number of IPX packets transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysCircCount 1.3.6.1.4.1.2.6.26.2.1.1.1.1.27
The number of circuits known to this instance of IPX.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysDestCount 1.3.6.1.4.1.2.6.26.2.1.1.1.1.28
The number of currently reachable destinations known to this instance of IPX.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysServCount 1.3.6.1.4.1.2.6.26.2.1.1.1.1.29
The number of services known to this instance of IPX.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysResourceFailures 1.3.6.1.4.1.2.6.26.2.1.1.1.1.30
The number of times this instance of IPX has been unable to obtain needed resources (memory, etc.).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysConfigSockets 1.3.6.1.4.1.2.6.26.2.1.1.1.1.31
The configured maximum number of IPX sockets that may be open at one time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysMaxOpenSockets 1.3.6.1.4.1.2.6.26.2.1.1.1.1.32
The maximum number of IPX sockets actually open at one time on this system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxSysOpenSocketFails 1.3.6.1.4.1.2.6.26.2.1.1.1.1.33
The number of IPX socket open calls which failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxCircTable 1.3.6.1.4.1.2.6.26.2.1.2.1
The Circuit table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IPXCircEntry

ipxCircEntry 1.3.6.1.4.1.2.6.26.2.1.2.1.1
Each entry corresponds to one circuit known to the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IPXCircEntry  

ipxCircSysInstance 1.3.6.1.4.1.2.6.26.2.1.2.1.1.1
The unique identifier of the instance of IPX to which this entry corresponds. This value may be written only when creating a new entry in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxCircIndex 1.3.6.1.4.1.2.6.26.2.1.2.1.1.2
The identifier of this circuit, unique within the instance of IPX. This value may be written only when creating a new entry in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxCircExistState 1.3.6.1.4.1.2.6.26.2.1.2.1.1.3
The validity of this circuit entry. A circuit with this value set to off may be deleted from the table at the IPX implementation's discretion.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ipxCircOperState 1.3.6.1.4.1.2.6.26.2.1.2.1.1.4
The operational state of the circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ipxCircIfIndex 1.3.6.1.4.1.2.6.26.2.1.2.1.1.5
The value of ifIndex for the interface used by this circuit. This value may be written only when creating a new entry in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxCircName 1.3.6.1.4.1.2.6.26.2.1.2.1.1.6
The readable name for the circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

ipxCircInfo 1.3.6.1.4.1.2.6.26.2.1.2.1.1.7
Additional readable information for the circuit. The content of this field is implementation defined.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

ipxCircType 1.3.6.1.4.1.2.6.26.2.1.2.1.1.8
The type of the circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), broadcast(2), ptToPt(3), wanRIP(4), unnumberedRIP(5), dwnamic(6), wanWS(7)  

ipxCircLocalMaxPacketSize 1.3.6.1.4.1.2.6.26.2.1.2.1.1.9
The maximum size (including header), in bytes, that the system supports locally on this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxCircCompressState 1.3.6.1.4.1.2.6.26.2.1.2.1.1.10
The compression state on this circuit. This value may be written only when creating a new entry in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ipxCircCompressSlots 1.3.6.1.4.1.2.6.26.2.1.2.1.1.11
The number of compression slots available on this circuit. This value may be written only when creating a new entry in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxCircCompressedSent 1.3.6.1.4.1.2.6.26.2.1.2.1.1.12
The number of compressed packets sent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxCircUncompressedSent 1.3.6.1.4.1.2.6.26.2.1.2.1.1.13
The number of packets sent without being compressed even though compression was turned on for this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxCircMediaType 1.3.6.1.4.1.2.6.26.2.1.2.1.1.14
The media type used on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

ipxCircNetNumber 1.3.6.1.4.1.2.6.26.2.1.2.1.1.15
The IPX network number to which this circuit is bound.
Status: mandatory Access: read-only
OBJECT-TYPE    
  NetNumber  

ipxCircStateChanges 1.3.6.1.4.1.2.6.26.2.1.2.1.1.16
The number of times the circuit has changed state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxCircInitFails 1.3.6.1.4.1.2.6.26.2.1.2.1.1.17
The number of times that initialization of this circuit has failed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ipxCircDelay 1.3.6.1.4.1.2.6.26.2.1.2.1.1.18
The period of time, in milliseconds, that it takes to transmit one byte of data, excluding protocol headers, to a destination on the other end of the circuit, if the circuit is free of other traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ipxCircThroughput 1.3.6.1.4.1.2.6.26.2.1.2.1.1.19
The amounf of data, in bits per second, that may flow through the circuit if there is no other traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ipxDestTable 1.3.6.1.4.1.2.6.26.2.1.3.1
The Destination table contains information about all known destinations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IPXDestEntry

ipxDestEntry 1.3.6.1.4.1.2.6.26.2.1.3.1.1
Each entry corresponds to one destination.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IPXDestEntry  

ipxDestSysInstance 1.3.6.1.4.1.2.6.26.2.1.3.1.1.1
The unique identifier of the instance of IPX to which this row corresponds. This value may be written only when creating a new entry with ipxDestProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxDestNetNum 1.3.6.1.4.1.2.6.26.2.1.3.1.1.2
The IPX network number of the destination. This value may be written only when creating a new entry with ipxDestProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NetNumber  

ipxDestProtocol 1.3.6.1.4.1.2.6.26.2.1.3.1.1.3
The routing protocol from which knowledge of this destination was obtained. This value may be written only when creating a new entry with ipxDestProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), local(2), rip(3), nlsp(4), static(5)  

ipxDestCost 1.3.6.1.4.1.2.6.26.2.1.3.1.1.4
The cost to reach this destination. The meaning of the cost value is dependent on the routing protocol (i. e. Cost = delay in ticks for RIP, Cost = total path default cost for NLSP, etc.). This value may be written only when creating a new entry with ipxDestProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxDestHopCount 1.3.6.1.4.1.2.6.26.2.1.3.1.1.5
The number of hops necessary to reach the destination. This value may be written only when creating a new entry with ipxDestProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxDestNextHopCircIndex 1.3.6.1.4.1.2.6.26.2.1.3.1.1.6
The unique identifier of the circuit used to reach the next hop. This value may be written only when creating a new entry with ipxDestProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxDestNextHopNICAddress 1.3.6.1.4.1.2.6.26.2.1.3.1.1.7
The NIC address of the next hop. This value may be written only when creating a new entry with ipxDestProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

ipxDestNextHopNetNum 1.3.6.1.4.1.2.6.26.2.1.3.1.1.8
The IPX network number of the next hop. This value may be written only when creating a new entry with ipxDestProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NetNumber  

ipxDestType 1.3.6.1.4.1.2.6.26.2.1.3.1.1.9
Indicates whether the destination is a network or a router.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), nlspLevel1Router(2), router(4), network(5)  

ipxServTable 1.3.6.1.4.1.2.6.26.2.1.4.1
The table of services, indexed by name and type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IPXServEntry

ipxServEntry 1.3.6.1.4.1.2.6.26.2.1.4.1.1
Each entry corresponds to one service.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IPXServEntry  

ipxServSysInstance 1.3.6.1.4.1.2.6.26.2.1.4.1.1.1
The unique identifier of the instance of IPX to which this entry corresponds. This value may be written only when creating entries with the value of ipxServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxServName 1.3.6.1.4.1.2.6.26.2.1.4.1.1.2
The service name. This value may be written only when creating entries with the value of ipxServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..48)  

ipxServTypeValue 1.3.6.1.4.1.2.6.26.2.1.4.1.1.3
The service type's hexadecimal value. This value may be written only when creating entries with the value of ipxServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2)  

ipxServType 1.3.6.1.4.1.2.6.26.2.1.4.1.1.4
The service type. This value may be written only when creating entries with the value of ipxServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1)  

ipxServProtocol 1.3.6.1.4.1.2.6.26.2.1.4.1.1.5
The protocol from which knowledge of this service was obtained. This value may be written only when the value of ipxServProtocol is equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), local(2), nlsp(4), static(5), sap(6)  

ipxServNetNum 1.3.6.1.4.1.2.6.26.2.1.4.1.1.6
The IPX network number portion of the IPX address of the service. This value may be written only when creating entries with the value of ipxServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NetNumber  

ipxServNode 1.3.6.1.4.1.2.6.26.2.1.4.1.1.7
The node portion of the IPX address of the service. This value may be written only when creating entries with the value of ipxServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

ipxServSocket 1.3.6.1.4.1.2.6.26.2.1.4.1.1.8
The socket portion of the IPX address of the service. This value may be written only when creating entries with the value of ipxServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2)  

ipxDestServTable 1.3.6.1.4.1.2.6.26.2.1.4.2
The table of services, indexed by address, name, and type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IPXDestServEntry

ipxDestServEntry 1.3.6.1.4.1.2.6.26.2.1.4.2.1
Each entry corresponds to one service.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IPXDestServEntry  

ipxDestServSysInstance 1.3.6.1.4.1.2.6.26.2.1.4.2.1.1
The unique identifier of the instance of IPX to which this entry corresponds. This value may be written only when creating entries with the value of ipxDestServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ipxDestServNetNum 1.3.6.1.4.1.2.6.26.2.1.4.2.1.2
The IPX network number portion of the IPX address of the service. This value may be written only when creating entries with the value of ipxDestServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  NetNumber  

ipxDestServNode 1.3.6.1.4.1.2.6.26.2.1.4.2.1.3
The node portion of the IPX address of the service. This value may be written only when creating entries with the value of ipxDestServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(6)  

ipxDestServSocket 1.3.6.1.4.1.2.6.26.2.1.4.2.1.4
The socket portion of the IPX address of the service. This value may be written only when creating entries with the value of ipxDestServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2)  

ipxDestServName 1.3.6.1.4.1.2.6.26.2.1.4.2.1.5
The service name. This value may be written only when creating entries with the value of ipxDestServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..48)  

ipxDestServTypeValue 1.3.6.1.4.1.2.6.26.2.1.4.2.1.6
The service type's hexadecimal value. This value may be written only when creating entries with the value of ipxDestServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2)  

ipxDestServType 1.3.6.1.4.1.2.6.26.2.1.4.2.1.7
The service type. This value may be written only when creating entries with the value of ipxDestServProtocol equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1)  

ipxDestServProtocol 1.3.6.1.4.1.2.6.26.2.1.4.2.1.8
The protocol from which knowledge of this service was obtained. This value may be written only when the value of ipxDestServProtocol is equal to static.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), local(2), nlsp(4), static(5), sap(6)  

ripsap 1.3.6.1.4.1.2.6.26.2.2
OBJECT IDENTIFIER    

ripsapSystem 1.3.6.1.4.1.2.6.26.2.2.1
OBJECT IDENTIFIER    

ripsapCircuit 1.3.6.1.4.1.2.6.26.2.2.2
OBJECT IDENTIFIER    

ripsapSysTable 1.3.6.1.4.1.2.6.26.2.2.1.1
The RIP/SAP system table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RIPSAPSysEntry

ripsapSysEntry 1.3.6.1.4.1.2.6.26.2.2.1.1.1
Each entry corresponds to one instance of RIP/SAP running on the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RIPSAPSysEntry  

ripsapSysInstance 1.3.6.1.4.1.2.6.26.2.2.1.1.1.1
The unique identifier of the instance of RIP/SAP to which this row corresponds. This value links the instance of RIP/SAP to an instance of IPX running on the system (i. e. the value of ripsapSysInstance should be the same as a value of ipxSysInstance). This value may be written only when creating a new entry in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ripsapSysRIPState 1.3.6.1.4.1.2.6.26.2.2.1.1.1.2
Indicates the operational state of this instance of RIP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ripsapSysSAPState 1.3.6.1.4.1.2.6.26.2.2.1.1.1.3
Indicates the operational state of this instance of SAP.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ripsapSysRIPIncorrectPackets 1.3.6.1.4.1.2.6.26.2.2.1.1.1.4
The number of times that an incorrectly formatted RIP packet was received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ripsapSysSAPIncorrectPackets 1.3.6.1.4.1.2.6.26.2.2.1.1.1.5
The number of times that an incorrectly formatted SAP packet was received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ripsapCircTable 1.3.6.1.4.1.2.6.26.2.2.2.1
The Circuit table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RIPSAPCircEntry

ripsapCircEntry 1.3.6.1.4.1.2.6.26.2.2.2.1.1
Each entry corresponds to one circuit known to the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RIPSAPCircEntry  

ripsapCircSysInstance 1.3.6.1.4.1.2.6.26.2.2.2.1.1.1
The unique identifier of the instance of RIP/SAP and IPX (via ipxSysInstance) to which this entry corresponds. This value may be written only when creating a new entry in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ripsapCircIndex 1.3.6.1.4.1.2.6.26.2.2.2.1.1.2
The identifier of this circuit, unique within the instance of RIP/SAP. This value corresponds to the circuit identifier found in ipxCircIndex. This value may be written only when creating a new entry in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ripsapCircRIPState 1.3.6.1.4.1.2.6.26.2.2.2.1.1.3
Indicates whether RIP information may be sent/received over this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ripsapCircRIPPace 1.3.6.1.4.1.2.6.26.2.2.2.1.1.4
The maximum pace, in packets per second, at which RIP packets may be sent on this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ripsapCircRIPUpdate 1.3.6.1.4.1.2.6.26.2.2.2.1.1.5
The RIP periodic update interval, in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ripsapCircRIPAgeMultiplier 1.3.6.1.4.1.2.6.26.2.2.2.1.1.6
The holding multiplier for information received in RIP periodic updates.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ripsapCircRIPPacketSize 1.3.6.1.4.1.2.6.26.2.2.2.1.1.7
The RIP packet size used on this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ripsapCircRIPOutPackets 1.3.6.1.4.1.2.6.26.2.2.2.1.1.8
The number of RIP packets sent on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ripsapCircRIPInPackets 1.3.6.1.4.1.2.6.26.2.2.2.1.1.9
The number of RIP packets received on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ripsapCircSAPState 1.3.6.1.4.1.2.6.26.2.2.2.1.1.10
Indicates whether SAP information may be sent/received over this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

ripsapCircSAPPace 1.3.6.1.4.1.2.6.26.2.2.2.1.1.11
The maximum pace, in packets per second, at which SAP packets may be sent on this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ripsapCircSAPUpdate 1.3.6.1.4.1.2.6.26.2.2.2.1.1.12
The SAP periodic update interval, in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ripsapCircSAPAgeMultiplier 1.3.6.1.4.1.2.6.26.2.2.2.1.1.13
The holding multiplier for information received in SAP periodic updates.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ripsapCircSAPPacketSize 1.3.6.1.4.1.2.6.26.2.2.2.1.1.14
The SAP packet size used on this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ripsapCircSAPGetNearestServerReply 1.3.6.1.4.1.2.6.26.2.2.2.1.1.15
Indicates whether to respond to SAP Get Nearest Server requests received on this circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

ripsapCircSAPOutPackets 1.3.6.1.4.1.2.6.26.2.2.2.1.1.16
The number of SAP packets sent on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ripsapCircSAPInPackets 1.3.6.1.4.1.2.6.26.2.2.2.1.1.17
The number of SAP packets received on this circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter