IBM2216-MIB

File: IBM2216-MIB.mib (11577 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

enterprises OBJECT-TYPE

Defined Types

Ibm2216PCIAdapEntry  
SEQUENCE    
  ibm2216PCIAdapSlotNum INTEGER
  ibm2216PCIAdapType INTEGER
  ibm2216PCIAdapOperStatus INTEGER

Ibm2216GraphicEntry  
SEQUENCE    
  ibm2216GraphicSlotNum INTEGER
  ibm2216GraphicPortNum INTEGER
  ibm2216GraphicifIndex INTEGER

Defined Values

ibm 1.3.6.1.4.1.2
OBJECT IDENTIFIER    

ibmProd 1.3.6.1.4.1.2.6
OBJECT IDENTIFIER    

ibm2216 1.3.6.1.4.1.2.6.131
OBJECT IDENTIFIER    

ibm2216admin 1.3.6.1.4.1.2.6.131.1
OBJECT IDENTIFIER    

ibm2216system 1.3.6.1.4.1.2.6.131.2
OBJECT IDENTIFIER    

ibm2216hardware 1.3.6.1.4.1.2.6.131.3
OBJECT IDENTIFIER    

ibm2216routing 1.3.6.1.4.1.2.6.131.4
OBJECT IDENTIFIER    

ibm2216switching 1.3.6.1.4.1.2.6.131.5
OBJECT IDENTIFIER    

ibm2216adminproducts 1.3.6.1.4.1.2.6.131.1.1
OBJECT IDENTIFIER    

ibm2216mod400 1.3.6.1.4.1.2.6.131.1.1.1
OBJECT IDENTIFIER    

ibm2216adminOID 1.3.6.1.4.1.2.6.131.1.2
OBJECT IDENTIFIER    

ibm2216adminDebug 1.3.6.1.4.1.2.6.131.1.3
OBJECT IDENTIFIER    

ibm2216systemInfo 1.3.6.1.4.1.2.6.131.2.1
OBJECT IDENTIFIER    

ibm2216cfgInfo 1.3.6.1.4.1.2.6.131.2.2
OBJECT IDENTIFIER    

ibm2216hardwareGeneral 1.3.6.1.4.1.2.6.131.3.1
OBJECT IDENTIFIER    

ibm2216hardware400Specific 1.3.6.1.4.1.2.6.131.3.2
OBJECT IDENTIFIER    

ibm2216EnetChipSet 1.3.6.1.4.1.2.6.131.1.2.1
OBJECT IDENTIFIER    

enetChipSetToshiba 1.3.6.1.4.1.2.6.131.1.2.1.1
OBJECT IDENTIFIER    

enetChipSetAMD 1.3.6.1.4.1.2.6.131.1.2.1.2
OBJECT IDENTIFIER    

ibm2216PCIAdapTable 1.3.6.1.4.1.2.6.131.3.1.1
A table of information about PCI adapters in this box.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ibm2216PCIAdapEntry

ibm2216PCIAdapEntry 1.3.6.1.4.1.2.6.131.3.1.1.1
An entry containing objects to describe the adapter in a given slot.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ibm2216PCIAdapEntry  

ibm2216PCIAdapSlotNum 1.3.6.1.4.1.2.6.131.3.1.1.1.1
The number identifying a slot location where an adapter can be inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

ibm2216PCIAdapType 1.3.6.1.4.1.2.6.131.3.1.1.1.2
The type of adapter that is inserted into this slot. If no adapter is present, the variable will take the value not-present(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-present(2), atm-mmf-lic294(3), atm-mmf-lic284(4), atm-smf-lic295(5), atm-smf-lic293(6), token-ring-lic280(7), escon-lic287(8), isdn-t1j1-lic283(9), isdn-e1-lic292(10), serial-rs232-lic282(11), serial-v35-lic290(12), serial-x21-lic291(13), ethernet-lic281(14), ethernet-fast-lic288(15), serial-hssi-lic289(16), fddi-lic286(17), isdn-t1j1-lic297(18), isdn-e1-lic298(19), parallel-channel-lic299(20)  

ibm2216PCIAdapOperStatus 1.3.6.1.4.1.2.6.131.3.1.1.1.3
The operational status of this PCI adapter. unknown (1) : If there was problem determining the operational status of the adapter. not-configured (2) : If the adapter inserted in the slot is recognized but no router configuration exists. not-present (3) : If no adapter is currently inserted. does-not-apply (4) : If this adapter does not contain an operational state. enable-pending (5) : If commands have been issued to enable the adapter but have not been completed. enabled (6) : If commands have been successfully issued to enable the adapter. disable-pending (7) : If commands have been issued to disable the adapter but have not been completed. disabled (8) : If commands have been successfully issued to disable the adapter. not-initialized (9) : If the adapter has not completed its initialization. unknown-device (10) : If the adapter inserted in the slot can not be recognized. hardware-error (11) : If the adapter can not be used nor made ready to be used. not-powered (12) : If the adapter has had a problem obtaining power from its slot. diagnostics (13) : If the adapter is currently undergoing diagnostics. wrs-available (14) : If the adapter is currently configured and available for WAN restoral. mis-configured (15) : If the adapter is inserted in the slot but the router configuration is of a different type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-configured(2), not-present(3), does-not-apply(4), enable-pending(5), enabled(6), disable-pending(7), disabled(8), not-initialized(9), unknown-device(10), hardware-error(11), not-powered(12), diagnostics(13), wrs-available(14), mis-configured(15)  

ibm2216GraphicTable 1.3.6.1.4.1.2.6.131.3.1.2
A table of information mapping a slot and port to an interface table ifIndex. An entry exists in this table only if the ifConnectorPresent object is true
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ibm2216GraphicEntry

ibm2216GraphicEntry 1.3.6.1.4.1.2.6.131.3.1.2.1
An entry mapping slot and port to an interface table ifIndex.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ibm2216GraphicEntry  

ibm2216GraphicSlotNum 1.3.6.1.4.1.2.6.131.3.1.2.1.1
The number identifying a slot location where an adapter can be inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

ibm2216GraphicPortNum 1.3.6.1.4.1.2.6.131.3.1.2.1.2
The number identifying a port on a given adapter. A port implies a physical connector is associated with it.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

ibm2216GraphicifIndex 1.3.6.1.4.1.2.6.131.3.1.2.1.3
The ifIndex of the interface table entry associated with this port on an adapter. By definition, the ifEntry has ifConnectorPresent = true.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER