IEEE8021-CFM-V2-MIB
File:
IEEE8021-CFM-V2-MIB.mib (32946 bytes)
Imported modules
Imported symbols
Defined Types
Ieee8021CfmStackEntry |
|
SEQUENCE |
|
|
|
|
ieee8021CfmStackifIndex |
InterfaceIndex |
|
|
ieee8021CfmStackServiceSelectorType |
IEEE8021ServiceSelectorType |
|
|
ieee8021CfmStackServiceSelectorOrNone |
IEEE8021ServiceSelectorValueOrNone |
|
|
ieee8021CfmStackMdLevel |
Dot1agCfmMDLevel |
|
|
ieee8021CfmStackDirection |
Dot1agCfmMpDirection |
|
|
ieee8021CfmStackMdIndex |
Unsigned32 |
|
|
ieee8021CfmStackMaIndex |
Unsigned32 |
|
|
ieee8021CfmStackMepId |
Dot1agCfmMepIdOrZero |
|
|
ieee8021CfmStackMacAddress |
MacAddress |
|
Ieee8021CfmVlanEntry |
|
SEQUENCE |
|
|
|
|
ieee8021CfmVlanComponentId |
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CfmVlanSelector |
IEEE8021ServiceSelectorValue |
|
|
ieee8021CfmVlanPrimarySelector |
IEEE8021ServiceSelectorValue |
|
|
ieee8021CfmVlanRowStatus |
RowStatus |
|
Ieee8021CfmDefaultMdEntry |
|
SEQUENCE |
|
|
|
|
ieee8021CfmDefaultMdComponentId |
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CfmDefaultMdPrimarySelectorType |
IEEE8021ServiceSelectorType |
|
|
ieee8021CfmDefaultMdPrimarySelector |
IEEE8021ServiceSelectorValue |
|
|
ieee8021CfmDefaultMdStatus |
TruthValue |
|
|
ieee8021CfmDefaultMdLevel |
Dot1agCfmMDLevelOrNone |
|
|
ieee8021CfmDefaultMdMhfCreation |
Dot1agCfmMhfCreation |
|
|
ieee8021CfmDefaultMdIdPermission |
Dot1agCfmIdPermission |
|
Ieee8021CfmConfigErrorListEntry |
|
SEQUENCE |
|
|
|
|
ieee8021CfmConfigErrorListSelectorType |
IEEE8021ServiceSelectorType |
|
|
ieee8021CfmConfigErrorListSelector |
IEEE8021ServiceSelectorValue |
|
|
ieee8021CfmConfigErrorListIfIndex |
InterfaceIndex |
|
|
ieee8021CfmConfigErrorListErrorType |
Dot1agCfmConfigErrors |
|
Ieee8021CfmMaCompEntry |
|
SEQUENCE |
|
|
|
|
ieee8021CfmMaComponentId |
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CfmMaCompPrimarySelectorType |
IEEE8021ServiceSelectorType |
|
|
ieee8021CfmMaCompPrimarySelectorOrNone |
IEEE8021ServiceSelectorValueOrNone |
|
|
ieee8021CfmMaCompMhfCreation |
Dot1agCfmMhfCreation |
|
|
ieee8021CfmMaCompIdPermission |
Dot1agCfmIdPermission |
|
|
ieee8021CfmMaCompNumberOfVids |
Unsigned32 |
|
|
ieee8021CfmMaCompRowStatus |
RowStatus |
|
Defined Values
ieee8021CfmV2Mib |
1.3.111.2.802.1.1.7 |
Connectivity Fault Management V2 module for
managing IEEE 802.1ag-2007.
Unless otherwise indicated, the references in this MIB
module are to IEEE 802.1Q-2005 as amended by IEEE 802.1ad,
IEEE 802.1ak, IEEE 802.1ag and IEEE 802.1ah.
Copyright (C) IEEE.
This version of this MIB module is part of IEEE802.1Q;
see the draft itself for full legal notices. |
MODULE-IDENTITY |
|
|
|
ieee8021CfmStackTable |
1.3.111.2.802.1.1.8.1.1.2 |
There is one CFM Stack table per bridge. It permits
the retrieval of information about the Maintenance Points
configured on any given interface.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ieee8021CfmStackEntry |
|
ieee8021CfmStackEntry |
1.3.111.2.802.1.1.8.1.1.2.1 |
The Stack table entry |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CfmStackEntry |
|
|
ieee8021CfmStackifIndex |
1.3.111.2.802.1.1.8.1.1.2.1.1 |
This object represents the Bridge Port or aggregated port
on which MEPs or MHFs might be configured.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this variable, and rearrange the
ieee8021CfmStackTable, so that it indexes the entry in the
interface table with the same value of ifAlias that it
indexed before the system restart. If no such entry exists,
then the system SHALL delete all entries in the
ieee8021CfmStackTable with the interface index.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
ieee8021CfmStackMdIndex |
1.3.111.2.802.1.1.8.1.1.2.1.6 |
The index of the Maintenance Domain in the ieee8021CfmMdTable
to which the MP is associated, or 0, if none. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
ieee8021CfmStackMaIndex |
1.3.111.2.802.1.1.8.1.1.2.1.7 |
The index of the MA in the ieee8021CfmMaNetTable and
ieee8021CfmMaCompTable to which the MP is associated, or 0, if
none. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
ieee8021CfmVlanTable |
1.3.111.2.802.1.1.8.1.3.2 |
This table defines the association of VIDs into VLANs. There
is an entry in this table, for each component of the bridge,
for each VID that is:
a) a VID belonging to a VLAN associated with more than
one VID; and
b) not the Primary VLAN of that VID.
The entry in this table contains the Primary VID of the VLAN.
By default, this table is empty, meaning that every VID is
the Primary VID of a single-VID VLAN.
VLANs that are associated with only one VID SHOULD NOT have
an entry in this table.
The writable objects in this table need to be persistent
upon reboot or restart of a device.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ieee8021CfmVlanEntry |
|
ieee8021CfmVlanEntry |
1.3.111.2.802.1.1.8.1.3.2.1 |
The VLAN table entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CfmVlanEntry |
|
|
ieee8021CfmVlanComponentId |
1.3.111.2.802.1.1.8.1.3.2.1.1 |
The bridge component within the system to which the information
in this ieee8021CfmVlanEntry applies. If the system is not a
Bridge, or if only one component is present in the Bridge, then
this variable (index) MUST be equal to 1.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CfmVlanSelector |
1.3.111.2.802.1.1.8.1.3.2.1.3 |
This is a service ID belonging to a service that is associated
with more than one Service Selector identifiers, and this is not the Primary
Service ID of the service. The type of this Service Selector is the same
as the primary Service Selector's type defined by ieee8021CfmMaCompPrimarySelectorType
in the ieee8021CfmMaCompTable.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021ServiceSelectorValue |
|
|
ieee8021CfmVlanPrimarySelector |
1.3.111.2.802.1.1.8.1.3.2.1.5 |
This is the Primary Service selector for a Service that is associated
with more than one Service Selector identifiers. This value MUST not
equal the value of ieee8021CfmVlanSelector. The type of this Service Selector is the same
as the primary Service Selector's type defined by ieee8021CfmMaCompPrimarySelectorType
in the ieee8021CfmMaCompTable.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
IEEE8021ServiceSelectorValue |
|
|
ieee8021CfmVlanRowStatus |
1.3.111.2.802.1.1.8.1.3.2.1.6 |
The status of the row.
The writable columns in a row can not be changed if the row
is active. All columns MUST have a valid value before a row
can be activated.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
ieee8021CfmDefaultMdTable |
1.3.111.2.802.1.1.8.1.2.5 |
For each bridge component, the Default MD Level Managed Object
controls MHF creation for VIDs that are not attached to a
specific Maintenance Association Managed Object, and Sender ID
TLV transmission by those MHFs.
For each Bridge Port, and for each VLAN ID whose data can
pass through that Bridge Port, an entry in this table is
used by the algorithm in subclause 22.2.3 only if there is no
entry in the Maintenance Association table defining an MA
for the same VLAN ID and MD Level as this table's entry, and
on which MA an Up MEP is defined. If there exists such an
MA, that MA's objects are used by the algorithm in
subclause 22.2.3 in place of this table entry's objects. The
agent maintains the value of ieee8021CfmDefaultMdStatus to
indicate whether this entry is overridden by an MA.
When first initialized, the agent creates this table
automatically with entries for all VLAN IDs,
with the default values specified for each object.
After this initialization, the writable objects in this
table need to be persistent upon reboot or restart of a
device.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ieee8021CfmDefaultMdEntry |
|
ieee8021CfmDefaultMdEntry |
1.3.111.2.802.1.1.8.1.2.5.1 |
The Default MD Level table entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CfmDefaultMdEntry |
|
|
ieee8021CfmDefaultMdComponentId |
1.3.111.2.802.1.1.8.1.2.5.1.1 |
The bridge component within the system to which the information
in this ieee8021CfmDefaultMdEntry applies. If the system is not
a Bridge, or if only one component is present in the Bridge,
then this variable (index) MUST be equal to 1.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CfmDefaultMdStatus |
1.3.111.2.802.1.1.8.1.2.5.1.4 |
State of this Default MD Level table entry. True if there is
no entry in the Maintenance Association table defining an MA
for the same VLAN ID and MD Level as this table's entry, and
on which MA an Up MEP is defined, else false.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
ieee8021CfmDefaultMdLevel |
1.3.111.2.802.1.1.8.1.2.5.1.5 |
A value indicating the MD Level at which MHFs are to be
created, and Sender ID TLV transmission by those MHFs is to
be controlled, for the VLAN to which this entry's objects
apply. If this object has the value -1, the MD Level for MHF
creation for this VLAN is controlled by
ieee8021CfmDefaultMdDefLevel.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Dot1agCfmMDLevelOrNone |
|
|
ieee8021CfmDefaultMdMhfCreation |
1.3.111.2.802.1.1.8.1.2.5.1.6 |
A value indicating if the Management entity can create MHFs
(MIP Half Function) for this VID at this MD Level. If this
object has the value defMHFdefer, MHF creation for this VLAN
is controlled by ieee8021CfmDefaultMdDefMhfCreation.
The value of this variable is meaningless if the values of
ieee8021CfmDefaultMdStatus is false.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Dot1agCfmMhfCreation |
|
|
ieee8021CfmDefaultMdIdPermission |
1.3.111.2.802.1.1.8.1.2.5.1.7 |
Enumerated value indicating what, if anything, is to be
included in the Sender ID TLV (21.5.3) transmitted by MHFs
created by the Default Maintenance Domain. If this object
has the value sendIdDefer, Sender ID TLV transmission for
this VLAN is controlled by ieee8021CfmDefaultMdDefIdPermission.
The value of this variable is meaningless if the values of
ieee8021CfmDefaultMdStatus is false.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Dot1agCfmIdPermission |
|
|
ieee8021CfmConfigErrorListEntry |
1.3.111.2.802.1.1.8.1.4.2.1 |
The Config Error List Table entry |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CfmConfigErrorListEntry |
|
|
ieee8021CfmConfigErrorListIfIndex |
1.3.111.2.802.1.1.8.1.4.2.1.3 |
This object is the IfIndex of the interface.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this variable so that it indexes the
entry in the interface table with the same value of ifAlias
that it indexed before the system restart. If no such
entry exists, then the system SHALL delete any entries in
ieee8021CfmConfigErrorListTable indexed by that
InterfaceIndex value.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
ieee8021CfmConfigErrorListErrorType |
1.3.111.2.802.1.1.8.1.4.2.1.4 |
A vector of Boolean error conditions from 22.2.4, any of
which may be true:
0) CFMleak;
1) ConflictingVids;
2) ExcessiveLevels;
3) OverlappedLevels.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Dot1agCfmConfigErrors |
|
|
ieee8021CfmMaCompTable |
1.3.111.2.802.1.1.8.1.6.4 |
The Maintenance Association table. Each row in the table
represents an MA. An MA is a set of MEPs, each configured
with a single service instance.
This is the part of the complete MA table that is variable
across the Bridges in a Maintenance Domain, or across the
components of a single Bridge. That part of the MA table that
is constant across the Bridges and their components in a
Maintenance Domain is contained in the ieee8021CfmMaNetTable.
This table uses three indices, first index is the
IEEE8021PbbComponentIdentifier that identifies the component
within the Bridge for which the information in the
ieee8021CfmMaCompEntry applies. The second is the index of the
Maintenance Domain table. The third index is the same as the
index of the ieee8021CfmMaNetEntry for the same MA.
The writable objects in this table need to be persistent
upon reboot or restart of a device.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ieee8021CfmMaCompEntry |
|
ieee8021CfmMaCompEntry |
1.3.111.2.802.1.1.8.1.6.4.1 |
The MA table entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CfmMaCompEntry |
|
|
ieee8021CfmMaComponentId |
1.3.111.2.802.1.1.8.1.6.4.1.1 |
The bridge component within the system to which the information
in this ieee8021CfmMaCompEntry applies. If the system is not a
Bridge, or if only one component is present in the Bridge, then
this variable (index) MUST be equal to 1.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CfmMaCompPrimarySelectorType |
1.3.111.2.802.1.1.8.1.6.4.1.2 |
Type of the Service Selector identifiers indicated by
ieee8021CfmMaCompPrimarySelectorOrNone. If the service instance is defined by more
than one Service Selector, this parameter also indicates the type of the
ieee8021CfmVlanPrimarySelector and ieee8021CfmVlanSelector in the ieee8021CfmVlanTable.
In Services instances made of multiple Service Selector identifiers, ensures that the
type of the Service selector identifiers is the same. See textual convention
Dot1agCfmServiceSelectorType for details.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
IEEE8021ServiceSelectorType |
|
|
ieee8021CfmMaCompIdPermission |
1.3.111.2.802.1.1.8.1.6.4.1.5 |
Enumerated value indicating what, if anything, is to be
included in the Sender ID TLV (21.5.3) transmitted by MPs
configured in this MA.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Dot1agCfmIdPermission |
|
|
ieee8021CfmMaCompRowStatus |
1.3.111.2.802.1.1.8.1.6.4.1.7 |
The status of the row.
The writable columns in a row can not be changed if the row
is active. All columns MUST have a valid value before a row
can be activated.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
ieee8021CfmStackGroup |
1.3.111.2.802.1.1.8.2.2.12 |
Objects for the Stack group. |
Status: current |
Access: read-create |
OBJECT-GROUP |
|
|
|
ieee8021CfmMaGroup |
1.3.111.2.802.1.1.8.2.2.13 |
Objects for the MA group. |
Status: current |
Access: read-create |
OBJECT-GROUP |
|
|
|
ieee8021CfmDefaultMdGroup |
1.3.111.2.802.1.1.8.2.2.14 |
Objects for the Default MD Level group. |
Status: current |
Access: read-create |
OBJECT-GROUP |
|
|
|
ieee8021CfmVlanIdGroup |
1.3.111.2.802.1.1.8.2.2.15 |
Objects for the VLAN ID group. |
Status: current |
Access: read-create |
OBJECT-GROUP |
|
|
|
ieee8021CfmConfigErrorListGroup |
1.3.111.2.802.1.1.8.2.2.16 |
Objects for the CFM Configuration Error List Group. |
Status: current |
Access: read-create |
OBJECT-GROUP |
|
|
|
ieee8021CfmComplianceV2 |
1.3.111.2.802.1.1.8.2.1.2 |
The compliance statement for support of the CFM MIB module. |
Status: current |
Access: not-accessible |
MODULE-COMPLIANCE |
|
|
|