IEEE8021-CN-MIB
File:
IEEE8021-CN-MIB.mib (74246 bytes)
Imported modules
Imported symbols
Defined Types
Ieee8021CnControlChoice |
|
This controls what other object selects the CND defense mode and
the Congestion Notification Priority Value (CNPV) alternate
priority for a CNPV in an end station or Bridge component, or
for a CNPV on a particular Port in an end station or Bridge
component. It can take the following values:
cpcAdmin(1) The CND defense mode and alternate priority are
controlled by the administrative variables in the
same table entry as this object.
cpcAuto(2) This Port or all Ports' CND defense modes are
controlled automatically, as indicated by
ieee8021CnPortPriAutoDefenseMode, and the
alternate priority by ieee8021CnComPriAutoAltPri.
cpcComp(3) This CND defense mode and alternate priority are
both controlled by ieee8021CnPortPriTable.
|
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
cpcAdmin(1), cpcAuto(2), cpcComp(3) |
|
Ieee8021CnDefenseMode |
|
For a given Congestion Notification Priority Value (CNPV), a
port can operate in one of four CND defense modes. The CND
defense mode determines whether congestion notification is
enabled or not, and if enabled, whether the port translates the
CNPV to a non-CNPV value on input, and whether the port removes
CNTAGs on output.
cptDisabled(1) The congestion notification capability is
administratively disabled for this priority
value and port. This priority is not a CNPV.
The priority regeneration table controls the
remapping of input frames on this port for
this priority. CNTAGs are neither added by
an end station nor stripped by a Bridge.
cptInterior(2) On this port and for this CNPV, the priority
parameters of input frames are not remapped,
regardless of the priority regeneration
table. CNTAGs are not added by an end
station, and are removed from frames before
being output by a Bridge.
cptInteriorReady(3) On this port and for this CNPV, the priority
parameters of input frames are not remapped,
regardless of the priority regeneration
table. CNTAGs can be added by an end
station, and are not removed from frames by
a Bridge.
cptEdge(4) On this port and for this CNPV, the priority
parameters of input frames are remapped to
an alternate (non-CNPV) value, regardless of
the priority regeneration table. CNTAGs are
not added by an end station, and are removed
from frames before being output by a Bridge.
This mode is optional for an end station.
|
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
cptDisabled(1), cptInterior(2), cptInteriorReady(3), cptEdge(4) |
|
Ieee8021CnLldpChoice |
|
Specifies how to determine what index value is to be used as
the index to lldpDestAddressTable, the table of destination MAC
addresses, for both the destination addresses on transmitted
LLDPDUs and on received LLDPDUs, found in the LLDP-MIB, either:
cnlNone(1) No LLDP Congestion Notification TLV is to
carry Per-priority CNPV indicators or
Per-priority Ready indicators on this Port
for this priority (or all Ports and all
priorities, as appropriate to the managed
object).
cnlAdmin(2) The administrative LLDP instance selector
in the same table entry as this object
governs which LLDP instance will carry the
Per-priority CNPV indicators and
Per-priority Ready indicators for this
priority in its Congestion Notification TLV
on this Port (or all Ports and all
priorities, as appropriate to the managed
object).
cnlComponent(3) ieee8021CnComPriLldpInstanceSelector governs
LLDP instance selection for this Port and
priority.
|
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
cnlNone(1), cnlAdmin(2), cnlComponent(3) |
|
Ieee8021CnGlobalEntry |
|
SEQUENCE |
|
|
|
|
ieee8021CnGlobalComponentId |
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnGlobalMasterEnable |
TruthValue |
|
|
ieee8021CnGlobalCnmTransmitPriority |
IEEE8021PriorityValue |
|
|
ieee8021CnGlobalDiscardedFrames |
Counter64 |
|
Ieee8021CnCompntPriEntry |
|
SEQUENCE |
|
|
|
|
ieee8021CnComPriComponentId |
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnComPriPriority |
IEEE8021PriorityValue |
|
|
ieee8021CnComPriDefModeChoice |
Ieee8021CnControlChoice |
|
|
ieee8021CnComPriAlternatePriority |
IEEE8021PriorityValue |
|
|
ieee8021CnComPriAutoAltPri |
IEEE8021PriorityValue |
|
|
ieee8021CnComPriAdminDefenseMode |
Ieee8021CnDefenseMode |
|
|
ieee8021CnComPriCreation |
INTEGER |
|
|
ieee8021CnComPriLldpInstanceChoice |
Ieee8021CnLldpChoice |
|
|
ieee8021CnComPriLldpInstanceSelector |
LldpV2DestAddressTableIndex |
|
|
ieee8021CnComPriRowStatus |
RowStatus |
|
Ieee8021CnPortPriEntry |
|
SEQUENCE |
|
|
|
|
ieee8021CnPortPriComponentId |
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnPortPriority |
IEEE8021PriorityValue |
|
|
ieee8021CnPortPriIfIndex |
InterfaceIndex |
|
|
ieee8021CnPortPriDefModeChoice |
Ieee8021CnControlChoice |
|
|
ieee8021CnPortPriAdminDefenseMode |
Ieee8021CnDefenseMode |
|
|
ieee8021CnPortPriAutoDefenseMode |
Ieee8021CnDefenseMode |
|
|
ieee8021CnPortPriLldpInstanceChoice |
Ieee8021CnLldpChoice |
|
|
ieee8021CnPortPriLldpInstanceSelector |
LldpV2DestAddressTableIndex |
|
|
ieee8021CnPortPriAlternatePriority |
IEEE8021PriorityValue |
|
Ieee8021CnCpEntry |
|
SEQUENCE |
|
|
|
|
ieee8021CnCpComponentId |
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnCpIfIndex |
InterfaceIndex |
|
|
ieee8021CnCpIndex |
Unsigned32 |
|
|
ieee8021CnCpPriority |
IEEE8021PriorityValue |
|
|
ieee8021CnCpMacAddress |
MacAddress |
|
|
ieee8021CnCpIdentifier |
OCTET STRING |
|
|
ieee8021CnCpQueueSizeSetPoint |
Unsigned32 |
|
|
ieee8021CnCpFeedbackWeight |
Integer32 |
|
|
ieee8021CnCpMinSampleBase |
Unsigned32 |
|
|
ieee8021CnCpDiscardedFrames |
Counter64 |
|
|
ieee8021CnCpTransmittedFrames |
Counter64 |
|
|
ieee8021CnCpTransmittedCnms |
Counter64 |
|
|
ieee8021CnCpMinHeaderOctets |
Unsigned32 |
|
Ieee8021CnCpidToInterfaceEntry |
|
SEQUENCE |
|
|
|
|
ieee8021CnCpidToIfCpid |
OCTET STRING |
|
|
ieee8021CnCpidToIfComponentId |
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnCpidToIfIfIndex |
InterfaceIndex |
|
|
ieee8021CnCpidToIfCpIndex |
Unsigned32 |
|
Ieee8021CnRpPortPriEntry |
|
SEQUENCE |
|
|
|
|
ieee8021CnRpPortPriComponentId |
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnRpPortPriPriority |
IEEE8021PriorityValue |
|
|
ieee8021CnRpPortPriIfIndex |
InterfaceIndex |
|
|
ieee8021CnRpPortPriMaxRps |
Unsigned32 |
|
|
ieee8021CnRpPortPriCreatedRps |
Counter32 |
|
|
ieee8021CnRpPortPriCentiseconds |
Counter64 |
|
Ieee8021CnRpGroupEntry |
|
SEQUENCE |
|
|
|
|
ieee8021CnRpgComponentId |
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnRpgPriority |
IEEE8021PriorityValue |
|
|
ieee8021CnRpgIfIndex |
InterfaceIndex |
|
|
ieee8021CnRpgIdentifier |
Unsigned32 |
|
|
ieee8021CnRpgEnable |
TruthValue |
|
|
ieee8021CnRpgTimeReset |
TimeInterval |
|
|
ieee8021CnRpgByteReset |
Unsigned32 |
|
|
ieee8021CnRpgThreshold |
Unsigned32 |
|
|
ieee8021CnRpgMaxRate |
Unsigned32 |
|
|
ieee8021CnRpgAiRate |
Unsigned32 |
|
|
ieee8021CnRpgHaiRate |
Unsigned32 |
|
|
ieee8021CnRpgGd |
Integer32 |
|
|
ieee8021CnRpgMinDecFac |
Unsigned32 |
|
|
ieee8021CnRpgMinRate |
Unsigned32 |
|
Defined Values
ieee8021CnMib |
1.3.111.2.802.1.1.18 |
Congestion notification module.
Unless otherwise indicated, the references in this MIB
module are to IEEE Std 802.1Q-2014.
Copyright (C) IEEE (2014).
This version of this MIB module is part of IEEE Std 802.1Q;
see the draft itself for full legal notices. |
MODULE-IDENTITY |
|
|
|
ieee8021CnGlobalTable |
1.3.111.2.802.1.1.18.1.1 |
A table containing the global variables for each component of
a Bridge or for an end station. A value of 1 is used in a
Bridge or end station that does not have multiple components.
The contents of this table SHALL be maintained across a restart
of the system.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ieee8021CnGlobalEntry |
|
ieee8021CnGlobalEntry |
1.3.111.2.802.1.1.18.1.1.1 |
A list of objects pertaining to a whole Bridge component or
end station.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnGlobalEntry |
|
|
ieee8021CnGlobalComponentId |
1.3.111.2.802.1.1.18.1.1.1.1 |
The Bridge component within the system to which the information
in this ieee8021CnGlobalEntry applies. If the system is not
a Bridge, or if only one component is present in the Bridge,
then this variable (index) MUST be equal to 1.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnGlobalMasterEnable |
1.3.111.2.802.1.1.18.1.1.1.2 |
The state of the congestion notification feature on this Bridge
component or system. If true, Congestion notification is
enabled, and if false, congestion notification is disabled.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
ieee8021CnGlobalDiscardedFrames |
1.3.111.2.802.1.1.18.1.1.1.4 |
The number of frames discarded from full CP queues, in spite
of the efforts of congestion notification to avoid discards.
This object is incremented whenever any of the
ieee8021CnCpDiscardedFrames objects on any Port or priority in
this same component are incremented.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime object of the associated
interface (if any).
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter64 |
|
|
ieee8021CnErroredPortTable |
1.3.111.2.802.1.1.18.1.2 |
There is one Errored Port Table per Bridge component or end
station. It permits the retrieval of information about which
interfaces have congestion notification configuration errors,
namely, those specifying an alternate priority that is a CNPV.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ieee8021CnErroredPortEntry |
|
ieee8021CnErroredPortEntry |
1.3.111.2.802.1.1.18.1.2.1 |
A list of interfaces whose ieee8021CnComPriAlternatePriority
and/or ieee8021CnPortPriAlternatePriority specify a priority
value that is a Congestion Notification Priority Value.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnErroredPortEntry |
|
|
ieee8021CnEpComponentId |
1.3.111.2.802.1.1.18.1.2.1.1 |
The Bridge component within the system to which the information
in this ieee8021CnErroredPortEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnEpIfIndex |
1.3.111.2.802.1.1.18.1.2.1.3 |
This object represents the Bridge Port or aggregated port
on which the congestion notification alternate priority is
misconfigured.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this variable so that it references the row
in the ifXTable with the same value of ifAlias that it
referenced before the system restart. If no such row exists,
then the system SHALL delete this row in the
ieee8021CnErroredPortTable.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
ieee8021CnCompntPriTable |
1.3.111.2.802.1.1.18.1.3 |
Each row in this table supplies default values for one
Congestion Notification Priority Value for a whole Bridge
component or end station.
Creating a row in this table makes the priority value of
ieee8021CnComPriPriority a
Congestion Notification Priority Value.
Deleting a row in this table makes the value in the deleted
ieee8021CnComPriPriority no longer a
Congestion Notification Priority Value.
A system SHALL NOT allow eight rows in this table
to be created with the same value of
ieee8021CnComPriComponentId; see the description of
ieee8021CnComPriRowStatus.
The contents of this table SHALL be maintained across a restart
of the system.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ieee8021CnCompntPriEntry |
|
ieee8021CnCompntPriEntry |
1.3.111.2.802.1.1.18.1.3.1 |
One entry per Congestion Notification Priority Value per
Bridge component or end station.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnCompntPriEntry |
|
|
ieee8021CnComPriComponentId |
1.3.111.2.802.1.1.18.1.3.1.1 |
The Bridge component within the system to which the information
in this ieee8021CnCompntPriEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnComPriDefModeChoice |
1.3.111.2.802.1.1.18.1.3.1.3 |
Specifies how the default CND defense mode and alternate
priority for this Congestion Notification Priority Value on all
ports on this Bridge component or end station are to be chosen,
either:
cpcAdmin(1) Default CND defense mode is chosen by
ieee8021CnComPriAdminDefenseMode, and alternate
priority by ieee8021CnComPriAlternatePriority.
cpcAuto(2) Default CND defense mode is chosen by
ieee8021CnPortPriAutoDefenseMode, and alternate
priority by ieee8021CnComPriAutoAltPri.
This variable can be overridden by
ieee8021CnPortPriDefModeChoice.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnControlChoice |
cpcAdmin(1), cpcAuto(2) |
|
ieee8021CnComPriAlternatePriority |
1.3.111.2.802.1.1.18.1.3.1.4 |
The Congestion Notification Priority Value to which an
incoming frame is to be mapped, in spite of what the
Priority Regereration Table says, if 1) Congestion
Notification is enabled and 2) the CND defense mode of the
port is cptEdge.
Deleting a row in this table does not alter the value of any
other row's ieee8021CnComPriAlternatePriority.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
IEEE8021PriorityValue |
|
|
ieee8021CnComPriAutoAltPri |
1.3.111.2.802.1.1.18.1.3.1.5 |
The Congestion Notification Priority Value to which an
incoming frame can be mapped, in spite of what the
Priority Regereration Table says, if 1) Congestion
Notification is enabled, 2) the CND defense mode of the
port is cptEdge, and 3) ieee8021CnComPriDefModeChoice
contains the value cpcAuto (2).
The value of this object is the next lower priority value
than this row's ieee8021CnComPriPriority that is not a CNPV,
or the next higher non-CNPV, if all lower values are CNPVs.
The value of this object, and any consequent priority
regeneration, is automatically updated by the managed system
whenever a row in the ieee8021CnCompntPriTable is created or
deleted. The value of this object is not dependent upon
whether congestion notification is enabled or disabled for any
priority or for the whole Bridge component or end station; it
depends only upon whether the ieee8021CnCompntPriTable row
exists.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
IEEE8021PriorityValue |
|
|
ieee8021CnComPriAdminDefenseMode |
1.3.111.2.802.1.1.18.1.3.1.6 |
The default CND defense mode for this
Congestion Notification Priority Value on all ports on this
Bridge component or end station.
This variable can be overridden by
ieee8021CnPortPriAdminDefenseMode.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnDefenseMode |
|
|
ieee8021CnComPriCreation |
1.3.111.2.802.1.1.18.1.3.1.7 |
The default value for ieee8021CnComPriDefModeChoice for
newly-created entries in the ieee8021CnPortPriTable:
cncpAutoEnable (1) Newly-created
ieee8021CnPortPriDefModeChoice
objects take the value cpcComp (3).
cncpAutoDisable(2) Newly-created
ieee8021CnPortPriDefModeChoice
objects take the value cpcAdmin (1).
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
cncpAutoEnable(1), cncpAutoDisable(2) |
|
ieee8021CnComPriLldpInstanceChoice |
1.3.111.2.802.1.1.18.1.3.1.8 |
Specifies whether or not the default value for all Ports is to
send and receive the Congestion Notification TLV in LLDPDUs,
either:
cnlNone(1) Do not send Congestion Notification TLVs, and
ignore them on receipt.
cnlAdmin(2) Use the LLDP instance selected by
ieee8021CnComPriLldpInstanceSelector to send and
receive the Congestion Notification TLV.
This object can be overridden by
ieee8021CnPortPriLldpInstanceChoice.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnLldpChoice |
cnlNone(1), cnlAdmin(2) |
|
ieee8021CnComPriLldpInstanceSelector |
1.3.111.2.802.1.1.18.1.3.1.9 |
Specifies a default value for which LLDP instance is to be
used to provide the information for automatic configuration
of ports' CND defense modes (ieee8021CnPortPriAutoDefenseMode).
This object is ignored by the managed system if
ieee8021CnComPriLldpInstanceChoice contains the value cnlNone
(1).
This object can be overridden by
ieee8021CnPortPriLldpInstanceChoice and
ieee8021CnPortPriLldpInstanceChoice.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
LldpV2DestAddressTableIndex |
|
|
ieee8021CnComPriRowStatus |
1.3.111.2.802.1.1.18.1.3.1.10 |
This object indicates the status of an entry, and is used
to create/delete entries.
A system SHALL NOT permit eight ieee8021CnComPriRowStatus
objects, all with the same value of ieee8021CnComPriComponentId,
to have the value active(1). An attempt to create or activate
a row when there are already seven active rows SHALL result in
that eighth row's ieee8021CnComPriRowStatus having the value
notReady(3), and the return of an inconsistentValue error.
|
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
ieee8021CnPortPriTable |
1.3.111.2.802.1.1.18.1.4 |
Each row in this table supplies values for one port's
Congestion Notification Priority Value (CNPV).
Creating an entry in ieee8021CnCompntPriTable creates this
entry, with the default values, on all ports in the Bridge
component or end station. Deleting an entry in
ieee8021CnCompntPriTable deletes this ieee8021CnCompntPriEntry
on all ports in the Bridge component or end station.
The contents of this table SHALL be maintained across a restart
of the system, except as noted in the description of
ieee8021CnPortPriIfIndex.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ieee8021CnPortPriEntry |
|
ieee8021CnPortPriEntry |
1.3.111.2.802.1.1.18.1.4.1 |
One entry per port per Congestion Notification Priority Value
per Bridge component or end station.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnPortPriEntry |
|
|
ieee8021CnPortPriComponentId |
1.3.111.2.802.1.1.18.1.4.1.1 |
The Bridge component within the system to which the information
in this ieee8021CnPortPriEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnPortPriIfIndex |
1.3.111.2.802.1.1.18.1.4.1.3 |
This object represents the port or aggregated port
to which the entry applies.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this object, and rearrange the order of the
ieee8021CnPortPriTable, so that the value in
ieee8021CnPortPriIfIndex references the row in the ifXTable
with the same value for ifAlias that it referenced before the
system restart. If no such entry exists in the ifXTable, then
the system SHALL delete the row in the ieee8021CnPortPriTable.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
ieee8021CnPortPriDefModeChoice |
1.3.111.2.802.1.1.18.1.4.1.4 |
This object determines how the CND defense mode and alternate
priority value of this port for this CNPV is to be selected,
either:
cpcAdmin(1) CND defense mode is controlled by
ieee8021CnPortPriAdminDefenseMode, and alternate
priority by ieee8021CnPortPriAlternatePriority.
cpcAuto(2) CND defense mode is controlled by
ieee8021CnPortPriAutoDefenseMode and alternate
priority by ieee8021CnComPriAlternatePriority.
cpcComp(3) CND defense mode and alternate priority are
controlled by
ieee8021CnComPriDefModeChoice.
This variable can override ieee8021CnComPriDefModeChoice.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnControlChoice |
|
|
ieee8021CnPortPriAdminDefenseMode |
1.3.111.2.802.1.1.18.1.4.1.5 |
This object indicates the operator's choice for the CND defense
mode in which this port is to operate for this CNPV whenever
ieee8021CnPortPriDefModeChoice has the value cpcAdmin(1).
This variable can override ieee8021CnComPriDefModeChoice.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnDefenseMode |
|
|
ieee8021CnPortPriAutoDefenseMode |
1.3.111.2.802.1.1.18.1.4.1.6 |
This object indicates in which the CND defense mode this port
would operate for this CNPV as determined by the LLDP
Congestion Notification TLV.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnDefenseMode |
cptInterior(2), cptInteriorReady(3), cptEdge(4) |
|
ieee8021CnPortPriLldpInstanceChoice |
1.3.111.2.802.1.1.18.1.4.1.7 |
Specifies how to determine the LLDP instance to be used for the
Congestion Notification TLV, either:
cnlNone(1) No LLDP Congestion Notification TLV is to
carry Per-priority CNPV indicators or
Per-priority Ready indicators on this Port
for this priority.
cnlAdmin(2) ieee8021CnPortPriLldpInstanceSelector
governs which LLDP instance is to carry
Per-priority CNPV indicators and
Per-priority Ready indicators for this
priority in its Congestion Notification TLV
on this Port
cnlComponent(3) ieee8021CnComPriLldpInstanceChoice
governs LLDP instance selection for this
Port and priority.
This object can override ieee8021CnComPriLldpInstanceChoice.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnLldpChoice |
|
|
ieee8021CnPortPriLldpInstanceSelector |
1.3.111.2.802.1.1.18.1.4.1.8 |
This object determines which LLDP instance selector, if any,
is used for automatic determination of the CND defense mode for
this port and CNPV.
This object can override ieee8021CnComPriLldpInstanceSelector.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
LldpV2DestAddressTableIndex |
|
|
ieee8021CnPortPriAlternatePriority |
1.3.111.2.802.1.1.18.1.4.1.9 |
The Congestion Notification Priority Value to which an
incoming frame is to be mapped, in spite of what the
Priority Regereration Table says, if 1) Congestion
Notification is enabled and 2) the port is acting in the
cptEdge (4) CND defense mode.
This object is ignored unless ieee8021CnPortPriDefModeChoice
contains the value cpcAdmin (1).
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IEEE8021PriorityValue |
|
|
ieee8021CnCpTable |
1.3.111.2.802.1.1.18.1.5 |
Each row in this table supplies values for one
Congestion Point (CP).
This table is indexed by component, port (interface), and
an arbitrary CP index. This arbitrary CP index is not
necessarily the Congestion Point Identifier (CPID) carried in
Congestion Notification Messages (CNMs).
Creating an entry in ieee8021CnCompntPriTable can create an
entry in this table, with the default values, on all ports in
the Bridge component or end station. Because more than one
Congestion Notification Priority Value (CNPV) can flow
through a single CP, the creation of an entry in
ieee8021CnCompntPriTable does not necessarily create a new
entry in this table. An end station can have more than one
CP for the same CNPV, so creating an entry in
ieee8021CnCompntPriTable can create multiple entries in this
table.
Because each port in a Bridge component or end station can have
a different relationship between CNPVs and CPs, the entries
created or deleted on each port can be different.
Deleting the last entry in ieee8021CnCompntPriTable for a
CNPV passing through the CP controlled by this entry deletes
the entry on some or all of the ports in the Bridge component
or end station.
Because each port in a Bridge component or end station can have
a different relationship between CNPVs and CPs, the entries
created or deleted on each port can be different.
The relationship between ieee8021CnCpIndex
values and CPs is an implementation dependent matter.
The contents of this table SHALL be maintained across a restart
of the system, except as noted in the description of
ieee8021CnCpIfIndex.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ieee8021CnCpEntry |
|
ieee8021CnCpEntry |
1.3.111.2.802.1.1.18.1.5.1 |
An entry in the Congestion Point table controls a single
Congestion Point on a port in a Bridge component or end station.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnCpEntry |
|
|
ieee8021CnCpComponentId |
1.3.111.2.802.1.1.18.1.5.1.1 |
The Bridge component within the system to which the information
in this ieee8021CnCpEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnCpIfIndex |
1.3.111.2.802.1.1.18.1.5.1.2 |
This object represents the port or aggregated port
to which the entry applies.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this object, and rearrange the order of the
ieee8021CnCpTable, so that the value in ieee8021CnCpIfIndex
references the row in the ifXTable with the same value for
ifAlias that it referenced before the system restart. If no
such entry exists in the ifXTable, then the system SHALL delete
the row in the ieee8021CnCpTable.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
ieee8021CnCpIndex |
1.3.111.2.802.1.1.18.1.5.1.3 |
This object is an arbitrary integer indexing the entries in
this table among the entries for the same component and
interface. In a system that supports no more than one
Congestion Point per priority per interface, ieee8021CnCpIndex
SHALL be equal to the lowest numerical
Congestion Notification Priority Value served by this
Congestion Point. Otherwise, it SHOULD be a small integer
value.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4096 |
|
ieee8021CnCpPriority |
1.3.111.2.802.1.1.18.1.5.1.4 |
This object indicates the lowest numerical
Congestion Notification Priority Value that this entry's
Congestion Point serves.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
IEEE8021PriorityValue |
|
|
ieee8021CnCpMacAddress |
1.3.111.2.802.1.1.18.1.5.1.5 |
This object indicates the MAC address used as the source
address in Congestion Notification Message transmitted
by this Congestion Point.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
MacAddress |
|
|
ieee8021CnCpIdentifier |
1.3.111.2.802.1.1.18.1.5.1.6 |
This object indicates the Congestion Point Identifier (CPID)
transmitted in Congestion Notification Message by this
Congestion Point.
It is not specified whether the CPID reported in a CNM by a CP
that serves multiple CNPVs does or does not have the same value
for its different CNPVs.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(8) |
|
ieee8021CnCpQueueSizeSetPoint |
1.3.111.2.802.1.1.18.1.5.1.7 |
This object is the set point for the queue managed by this
Congestion Point (CP). Congestion Notification Messages are
transmitted to the sources of frames queued in this CP's
queue in order to keep the total number of octets stored in
the queue at this set point.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
100..4294967295 |
|
ieee8021CnCpFeedbackWeight |
1.3.111.2.802.1.1.18.1.5.1.8 |
This object controls the weight (cpW) change in queue length
in the calculation of cpFb when the Congestion Point is
generating a Congestion Notification Message.
The weight cpW is equal to two to the power of this object.
Thus, if this object contains a -1, cpW = 1/2.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
-10..10 |
|
ieee8021CnCpMinSampleBase |
1.3.111.2.802.1.1.18.1.5.1.9 |
This object determines the minimum number of octets to
enqueue in the Congestion Point's queue between transmissions
of Congestion Notification Messages.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
10000..4294967295 |
|
ieee8021CnCpDiscardedFrames |
1.3.111.2.802.1.1.18.1.5.1.10 |
The number of data frames discarded by the queue controlled
by this Congestion Point due to queue congestion.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime object of the associated
interface (if any).
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter64 |
|
|
ieee8021CnCpTransmittedFrames |
1.3.111.2.802.1.1.18.1.5.1.11 |
The number of data frames passed on to the queue controlled by
this Congestion Point that were not discarded due to queue
congestion.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime object of the associated
interface (if any).
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter64 |
|
|
ieee8021CnCpTransmittedCnms |
1.3.111.2.802.1.1.18.1.5.1.12 |
The number of Congestion Notification Message transmitted
by this Congestion Point.
Discontinuities in the value of this counter can occur
at re-initialization of the management system, and at
other times as indicated by the value of
ifCounterDiscontinuityTime object of the associated
interface (if any).
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter64 |
|
|
ieee8021CnCpidToInterfaceTable |
1.3.111.2.802.1.1.18.1.6 |
This table allows the network manager to obtain the
interface index and CP index needed to access an entry in
the ieee8021CnCpTable, given a Congestion Point Identifier
(CPID) received a Congestion Notification Messages (CNMs).
Upon a restart of the system, the system SHALL, if necessary,
update this table to be consistent with the ieee8021CnCpTable.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ieee8021CnCpidToInterfaceEntry |
|
ieee8021CnCpidToInterfaceEntry |
1.3.111.2.802.1.1.18.1.6.1 |
An entry in the ieee8021CnCpidToInterfaceTable. Translates
a Congestion Point Identifier to a component identifier,
interface index, and CP index
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnCpidToInterfaceEntry |
|
|
ieee8021CnCpidToIfCpid |
1.3.111.2.802.1.1.18.1.6.1.1 |
This object is the Congestion Point Identifier (CPID)
transmitted in Congestion Notification Message by a
Congestion Point residing in this Bridge component or
end station.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(8) |
|
ieee8021CnCpidToIfComponentId |
1.3.111.2.802.1.1.18.1.6.1.2 |
The Bridge component within the system to which the information
in this ieee8021CnCpidToInterfaceEntry applies. If the system
is not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnCpidToIfIfIndex |
1.3.111.2.802.1.1.18.1.6.1.3 |
This object indicates the interface on which the selected
Congestion Point resides. This value can be used, along
with ieee8021CnCpidToIfCpIndex, to find the Congestion Point
in the ieee8021CnCpTable.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
ieee8021CnCpidToIfCpIndex |
1.3.111.2.802.1.1.18.1.6.1.4 |
This object indicates the Congestion Point's index on the
interface on which the selected Congestion Point resides.
This value can be used, along with ieee8021CnCpidToIfIfIndex,
to find the Congestion Point in the ieee8021CnCpTable.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4096 |
|
ieee8021CnRpPortPriTable |
1.3.111.2.802.1.1.18.1.7 |
Each row in this table supplies values for all of the
Reaction Points (RPs) on one Port and one priority of an end
station or Bridge component. This table is indexed by
component, port (interface), and priority.
Creating an entry in ieee8021CnCompntPriTable can create an
entry in this table, with the default values, on all ports
in the end station.
Deleting the an entry in ieee8021CnCompntPriTable for a
CNPV passing through the RP controlled by this entry deletes
entries on some or all of the ports in the end station.
The contents of this table SHALL be maintained across a restart
of the system, except as noted in the description of
ieee8021CnRpPortPriIfIndex.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ieee8021CnRpPortPriEntry |
|
ieee8021CnRpPortPriEntry |
1.3.111.2.802.1.1.18.1.7.1 |
An entry in the Reaction Point table controls all of the
Reaction Points on a port in an end station that share the same
priority value.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnRpPortPriEntry |
|
|
ieee8021CnRpPortPriComponentId |
1.3.111.2.802.1.1.18.1.7.1.1 |
The Bridge component within the system to which the information
in this ieee8021CnRpGroupEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnRpPortPriPriority |
1.3.111.2.802.1.1.18.1.7.1.2 |
This object indicates the lowest numerical
Congestion Notification Priority Value that this entry's
Reaction Point serves.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021PriorityValue |
|
|
ieee8021CnRpPortPriIfIndex |
1.3.111.2.802.1.1.18.1.7.1.3 |
This object indicates the interface on which the selected
Reaction Points reside.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this object, and rearrange the order of the
ieee8021CnRpPortPriTable, so that the value in
ieee8021CnRpPortPriIfIndex references the row in the ifXTable
with the same value for ifAlias that it referenced before the
system restart. If no such entry exists in the ifXTable, then
the system SHALL delete the row in the
ieee8021CnRpPortPriTable.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
ieee8021CnRpPortPriMaxRps |
1.3.111.2.802.1.1.18.1.7.1.4 |
An integer controlling the maximum number of Reaction Points
allowed for this CNPV on this Port. An end station SHALL
not create more than this many Reaction Point on this Port,
but it MAY create fewer.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..100 |
|
ieee8021CnRpPortPriCreatedRps |
1.3.111.2.802.1.1.18.1.7.1.5 |
This object returns the number of times any of the
Reaction Points (RPs) controlled by this entry has had
its rpEnabled variable set TRUE by the reception of a
Congestion Notification Message.
Dividing the change in ieee8021CnRpPortPriCentiseconds by the
change in this object over a time interval yields the average
lifetime of an active RP during that interval.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
ieee8021CnRpPortPriCentiseconds |
1.3.111.2.802.1.1.18.1.7.1.6 |
This object returns the total number of centi-seconds that
any of the Reaction Points (RPs) controlled by this entry
has had its rpEnabled variable in the TRUE state. That is,
once each centi-second, this counter is incremented by the
number of RPs this entry controls that are actively rate
limiting output frames.
Dividing the change in this object over a time interval by the
length of the interval yields the average number of RPs active
over that interval. Dividing the change in this object by the
change in ieee8021CnRpPortPriCreatedRps over that same time
interval yields the average lifetime of an active RP during that
interval.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter64 |
|
|
ieee8021CnRpGroupTable |
1.3.111.2.802.1.1.18.1.8 |
Each row in this table supplies values for one or more
Reaction Points (RPs). This table is indexed by component,
port (interface), and an arbitrary RP index.
Creating an entry in ieee8021CnCompntPriTable can create an
entry in this table, with the default values, on all ports
in the end station. An end station can have more than one
RP for the same Congestion Notification Priority Value
(CNPV), so creating an entry in ieee8021CnCompntPriTable can
create multiple entries in this table.
Because each port in a Bridge component or end station can have
a different relationship between CNPVs and RPs, the entries
created or deleted on each port can be different.
Deleting the an entry in ieee8021CnCompntPriTable for a
CNPV passing through the RP controlled by this entry deletes
entries on some or all of the ports in the end station.
Because each port in an end station can have a
different relationship between CNPVs and RPs, the entries
created or deleted on each port can be different.
The relationship between ieee8021CnRpgIdentifier
values and RPs is an implementation dependent matter.
The contents of this table SHALL be maintained across a restart
of the system, except as noted in the description of
ieee8021CnRpgIfIndex.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ieee8021CnRpGroupEntry |
|
ieee8021CnRpGroupEntry |
1.3.111.2.802.1.1.18.1.8.1 |
An entry in the Reaction Point table controls a group of
Reaction Points, on a port in an end station. All of the
Reaction Point controlled by this entry serve the same
Congestion Notification Priority Value.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ieee8021CnRpGroupEntry |
|
|
ieee8021CnRpgComponentId |
1.3.111.2.802.1.1.18.1.8.1.1 |
The Bridge component within the system to which the information
in this ieee8021CnRpGroupEntry applies. If the system is
not a Bridge, or if only one component is present in the
Bridge, then this variable (index) MUST be equal to 1.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021PbbComponentIdentifier |
|
|
ieee8021CnRpgPriority |
1.3.111.2.802.1.1.18.1.8.1.2 |
This object indicates the lowest numerical
Congestion Notification Priority Value that this entry's
Reaction Point serves.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IEEE8021PriorityValue |
|
|
ieee8021CnRpgIfIndex |
1.3.111.2.802.1.1.18.1.8.1.3 |
This object indicates the interface on which the group of
Reaction Points reside.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this object, and rearrange the order of the
ieee8021CnRpGroupTable, so that the value in
ieee8021CnRpgIfIndex references the row in the ifXTable with
the same value for ifAlias that it referenced before the system
restart. If no such entry exists in the ifXTable, then the
system SHALL delete the row in the ieee8021CnRpGroupTable.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
ieee8021CnRpgIdentifier |
1.3.111.2.802.1.1.18.1.8.1.4 |
This object is an arbitrary integer indexing the entries in
this table among the entries for the same interface. This
index SHOULD, where possible, be equal to the
Congestion Notification Priority Value served by this
Reaction Point.
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..4096 |
|
ieee8021CnRpgEnable |
1.3.111.2.802.1.1.18.1.8.1.5 |
Controls the rpEnabled variable of the Reaction Point state
machines of the Reaction Points (RPs) controlled by this
entry as follows:
true(1) The rpEnabled variable for the RPs controlled by
this object are not held in the FALSE state,
thus enabling them to pay attention to received
CNMs.
false(2) The rpEnabled variable for the RPs controlled by
this object are held in the FALSE state, thus
disabling them from paying attention to received
CNMs.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TruthValue |
|
|
ieee8021CnRpgTimeReset |
1.3.111.2.802.1.1.18.1.8.1.6 |
This object controls the value for all of the state machine
variables, rpgTimeReset, used to reset the timers RpWhile.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
TimeInterval |
|
|
ieee8021CnRpgByteReset |
1.3.111.2.802.1.1.18.1.8.1.7 |
This object controls the value for all of the state machine
variables, rpgByteReset, used to reset the counters
rpByteCount.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
ieee8021CnRpgThreshold |
1.3.111.2.802.1.1.18.1.8.1.8 |
This object controls the number of times rpByteStage or
rpTimeStage can count before the
RP rate control state machine advances states.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
ieee8021CnRpgMaxRate |
1.3.111.2.802.1.1.18.1.8.1.9 |
This object controls the maximum rate, in multiples of 1 Mbit/s,
at which an RP can transmit. Default value is the speed of the
port. A system SHALL support a minimim value for this object
that is no larger than 5 Mbits/s (object value 5). This rate
includes all bits consequent to transmitting the frame on the
LAN, including preamble, inter-frame gap, etc.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
ieee8021CnRpgAiRate |
1.3.111.2.802.1.1.18.1.8.1.10 |
This object controls the transmission rate increment in the
RPR_ACTIVE_INCREASE state (rpgAiRate) in multiples of 1 Mbit/s.
This rate includes all bits consequent to transmitting the
frame on the LAN, including preamble, inter-frame gap, etc.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
ieee8021CnRpgHaiRate |
1.3.111.2.802.1.1.18.1.8.1.11 |
This object controls the transmission rate increment in the
RPR_HYPER_INCREASE state (rpgHaiRate) in multiples of 1 Mbit/s.
This rate includes all bits consequent to transmitting the
frame on the LAN, including preamble, inter-frame gap, etc.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
ieee8021CnRpgGd |
1.3.111.2.802.1.1.18.1.8.1.12 |
This object controls the number of bits that the value of the
Quantized Feedback field received in a CNM PDU is shifted to
the right to decrease rpTargetRate. rpgGd is thus 2 to the
negative power of this object, e.g., 7 means rpgGd = 1/128.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
ieee8021CnRpgMinDecFac |
1.3.111.2.802.1.1.18.1.8.1.13 |
This object controls the minimum factor by which the current
RP transmit rate rpCurrentRate can be changed by reception
of a Congestion Notification Message. Its integer value
represents a percentage, from 1% to 100%.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
1..100 |
|
ieee8021CnRpgMinRate |
1.3.111.2.802.1.1.18.1.8.1.14 |
This object controls the minimum transmission rate (rpgMinRate)
in multiples of 1 Mbit/s. A system SHALL support a value for
this object that is no larger than 5 Mbit/s per second.
This rate includes all bits consequent to transmitting the
frame on the LAN, including preamble, inter-frame gap, etc.
|
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
ieee8021CnGlobalReqdGroup |
1.3.111.2.802.1.1.18.2.2.1 |
Objects in the global required group. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
ieee8021CnCpGlobalGroup |
1.3.111.2.802.1.1.18.2.2.2 |
Objects in the Congestion Point global group. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
ieee8021CnCpidTranslateGroup |
1.3.111.2.802.1.1.18.2.2.3 |
Objects in the CPID translate group. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
ieee8021CnEplGroup |
1.3.111.2.802.1.1.18.2.2.4 |
Objects for the Errored Ports Table group. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
ieee8021CnComPriGroup |
1.3.111.2.802.1.1.18.2.2.5 |
Objects for the global per-priority group. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
ieee8021CnCpPriGroup |
1.3.111.2.802.1.1.18.2.2.6 |
Objects for the Congestion Point per-priority group. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
ieee8021CnGlobalPriPortGroup |
1.3.111.2.802.1.1.18.2.2.7 |
Objects for the global per-priority per-port group. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
ieee8021CnCpPriPortGroup |
1.3.111.2.802.1.1.18.2.2.8 |
Objects for the Congestion Point per-priority per-port
group.
|
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
ieee8021CnCpGroup |
1.3.111.2.802.1.1.18.2.2.9 |
Objects for the Congestion Point group. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
ieee8021CnRpppGroup |
1.3.111.2.802.1.1.18.2.2.10 |
Objects for the Reaction Point per-Port per-priority group. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
ieee8021CnRpGroup |
1.3.111.2.802.1.1.18.2.2.11 |
Objects for the Reaction Point group. |
Status: current |
Access: read-write |
OBJECT-GROUP |
|
|
|
ieee8021CnBridgeCompliance |
1.3.111.2.802.1.1.18.2.1.1 |
The compliance statement for support by a Bridge of
the IEEE8021-MIRP-MIB module. |
Status: current |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|
ieee8021CnStationCompliance |
1.3.111.2.802.1.1.18.2.1.2 |
The compliance statement for support by an end station of
the IEEE8021-MIRP-MIB module. |
Status: current |
Access: read-write |
MODULE-COMPLIANCE |
|
|
|