IMMALERT-MIB

File: IMMALERT-MIB.mib (46219 bytes)

Imported modules

RFC-1212 RFC1155-SMI RFC1213-MIB

Imported symbols

OBJECT-TYPE enterprises Counter
TimeTicks IpAddress mib-2
DisplayString

Defined Values

ibm 1.3.6.1.4.1.2
OBJECT IDENTIFIER    

ibmProd 1.3.6.1.4.1.2.6
OBJECT IDENTIFIER    

supportProcessor 1.3.6.1.4.1.2.6.158
OBJECT IDENTIFIER    

immalertMIB 1.3.6.1.4.1.2.6.158.5
OBJECT IDENTIFIER    

immtrapg 1.3.6.1.4.1.2.6.158.5.1
OBJECT IDENTIFIER    

altDateTime 1.3.6.1.4.1.2.6.158.5.1.1
Timestamp of Local Date and Time when alert was generated
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altSpTxtId 1.3.6.1.4.1.2.6.158.5.1.3
SP System Identification - Text Identification
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altSysUuid 1.3.6.1.4.1.2.6.158.5.1.5
Host System UUID(Universal Unique ID)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altSysSern 1.3.6.1.4.1.2.6.158.5.1.6
Host System Serial Number
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altPriority 1.3.6.1.4.1.2.6.158.5.1.8
Alert Severity Value - Critical Alert(0) - Non-Critical Alert(2) - System Alert(4) - Recovery(8)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

altMsgText 1.3.6.1.4.1.2.6.158.5.1.9
Alert Message Text
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altMsgID 1.3.6.1.4.1.2.6.158.5.1.10
Alert Message ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

altMsgIDPrefix 1.3.6.1.4.1.2.6.158.5.1.11
Alert Message ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altHostContact 1.3.6.1.4.1.2.6.158.5.1.12
Host Contact
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altHostLocation 1.3.6.1.4.1.2.6.158.5.1.13
Host Location
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altHostRoomID 1.3.6.1.4.1.2.6.158.5.1.14
Host Location - Room ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altHostRackID 1.3.6.1.4.1.2.6.158.5.1.15
Host Location - Rack ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altHostLowestUpos 1.3.6.1.4.1.2.6.158.5.1.16
Host Location - Lowest U-position
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altHostBladeBay 1.3.6.1.4.1.2.6.158.5.1.17
Host Location - BladeBay
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altEventID 1.3.6.1.4.1.2.6.158.5.1.18
Event Identifier
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altServiceable 1.3.6.1.4.1.2.6.158.5.1.19
Serviceability information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notServiceable(0), serviceableByIBM(1), serviceableByCustomer(2)  

altTest 1.3.6.1.4.1.2.6.158.5.1.20
This event generated for test purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER false(0), true(1)  

altFailingFRUs 1.3.6.1.4.1.2.6.158.5.1.21
Ordered list of Failing FRU Numbers, separated by commas.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altHostMTM 1.3.6.1.4.1.2.6.158.5.1.22
Machine Type and Model for failing host.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

altAuxData 1.3.6.1.4.1.2.6.158.5.1.23
Auxiliary data that may be included for some events.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ibmSpTrapTempC 0
Critical Alert: Temperature threshold exceeded.
TRAP-TYPE    

ibmSpTrapVoltC 1
Critical Alert: Voltage threshold exceeded.
TRAP-TYPE    

ibmSpTrapPowerC 4
Critical Alert: Power failure.
TRAP-TYPE    

ibmSpTrapHdC 5
Critical Alert: Hard disk drive failure.
TRAP-TYPE    

ibmSpTrapFanC 11
Critical Alert: Single Fan failure.
TRAP-TYPE    

ibmSpTrapIhcC 36
Critical Alert: Incompatible hardware configuration.
TRAP-TYPE    

ibmSpTrapCPUC 40
Critical Alert: CPU Error.
TRAP-TYPE    

ibmSpTrapMemoryC 41
Critical Alert: Memory Error.
TRAP-TYPE    

ibmSpTrapRdpsC 9
Critical Alert: Redundant Power Supply failure.
TRAP-TYPE    

ibmSpTrapHardwareC 50
Critical Alert: Other Failure - refer to Message ID for specific condition.
TRAP-TYPE    

ibmSpTrapRdpsN 10
Non-Critical Alert: Redundant Power Supply failure.
TRAP-TYPE    

ibmSpTrapTempN 12
Non-Critical Alert: Temperature threshold exceeded.
TRAP-TYPE    

ibmSpTrapVoltN 13
Non-Critical Alert: Voltage threshold exceeded.
TRAP-TYPE    

ibmSpTrapPowerN 164
Non-Critical Alert: Power.
TRAP-TYPE    

ibmSpTrapFanN 165
Non-Critical Alert: Fan Error.
TRAP-TYPE    

ibmSpTrapCPUN 42
Non-Critical Alert: CPU Error.
TRAP-TYPE    

ibmSpTrapMemoryN 43
Non-Critical Alert: Memory Error.
TRAP-TYPE    

ibmSpTrapHardwareN 60
Non-Critical Alert: Warning - refer to Message ID for specific condition.
TRAP-TYPE    

ibmSpTrapRLogin 30
Sev-Off Alert: Event Remote Login.
TRAP-TYPE    

ibmSpTrapOsToS 21
System Alert: OS Timeout value exceeded.
TRAP-TYPE    

ibmSpTrapAppS 22
System Alert: Application Alert. Refer to Message ID for specific condition.
TRAP-TYPE    

ibmSpTrapPoffS 23
System Alert: Power Off.
TRAP-TYPE    

ibmSpTrapPonS 24
System Alert: Power On.
TRAP-TYPE    

ibmSpTrapBootS 25
System Alert: System Boot Failure.
TRAP-TYPE    

ibmSpTrapLdrToS 26
System Alert: OS Loader Timeout.
TRAP-TYPE    

ibmSpTrapPFAS 27
System Alert: Predictive Failure Analysis(PFA) information.
TRAP-TYPE    

ibmSpTrapSysLogS 35
System Alert: System Log 75% full.
TRAP-TYPE    

ibmSpTrapNwChangeS 37
System Alert: Network change notification.
TRAP-TYPE