INNOVX-DTE-MIB

File: INNOVX-DTE-MIB.mib (11337 bytes)

Imported modules

RFC-1212 RFC1213-MIB INNOVX-CORE-MIB

Imported symbols

OBJECT-TYPE DisplayString dteGroup

Defined Values

dteAdmin 1.3.6.1.4.1.498.22.1.6.1
OBJECT IDENTIFIER    

dteCfg 1.3.6.1.4.1.498.22.1.6.2
OBJECT IDENTIFIER    

dteAlarmCfg 1.3.6.1.4.1.498.22.1.6.3
OBJECT IDENTIFIER    

dteDiagnostics 1.3.6.1.4.1.498.22.1.6.4
OBJECT IDENTIFIER    

dteStatus 1.3.6.1.4.1.498.22.1.6.5
OBJECT IDENTIFIER    

dtesMIBversion 1.3.6.1.4.1.498.22.1.6.1.1
Identifies the version of the MIB as `X.YZT' where: X: Major Revision (1-9) Y: Minor Revision (0-9) Z: Typographical Revision (0-9) T: Test Revision (A-Z) Upon formal release, the test revision will not be present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(5)  

dteInterfaceType 1.3.6.1.4.1.498.22.1.6.2.1
Defines the DTE Interface Type. WEBFLAG V.28 V.35 RS-449 EIA-530 EIA-530A X.21 WEBEND
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER v28(1), v35(2), rs449(3), eia530(4), eia530a(5), x21(6)  

dteTxInvertingTiming 1.3.6.1.4.1.498.22.1.6.2.2
normal(1) tx timing clocks the transmit data from the DTE using an internal generated clock. invert (2) Invert Internally generated transmit clock used to sample the transmit data from the DTE. external(3) uses the DTE clock, EXTCLK, to clock the transmit data from the DTE. WEBFLAG Slave Normal Slave Inverted External WEBEND
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER slaveNormal(1), slaveInvert(2), external(3)  

dteRxCarrier 1.3.6.1.4.1.498.22.1.6.2.3
The Receive Carrier option. This option controls the operation of DCD. WEBFLAG Forced On Normal Operation WEBEND
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forcedOn(1), normal(2)  

dteDsrControl 1.3.6.1.4.1.498.22.1.6.2.4
The DSR option. This option controls the operation of DSR. When forcedOn(1) is selected, DSR is normally on, if set for followsDTR(2) then DSR is on only when DTR is on. WEBFLAG Forced On Follows DTR WEBEND
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER forcedOn(1), followsDTR(2)  

dteDtrLossTrapSeverity 1.3.6.1.4.1.498.22.1.6.3.1
Controls the reporting and defines the severity of the Channel Data Terminal Ready Loss Alarm when this event occurs. WEBFLAG Inhibit Critical Major Minor Warning Info WEBEND
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inhibit(1), critical(2), major(3), minor(4), warning(5), info(6)  

dteLoopback 1.3.6.1.4.1.498.22.1.6.4.1
Control the DTE loopback to the channel. noTest(1) stops the test. toChan(2) starts a loopback toward the DTE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noTest(1), toChan(2)  

dteDiagTestDuration 1.3.6.1.4.1.498.22.1.6.4.2
Defines the length of the diagnostic test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER testTime1Min(1), testTime5Mins(2), testTime10Mins(3), testTime20Mins(4)  

dteDiagTestStatus 1.3.6.1.4.1.498.22.1.6.4.3
Displays the test in progress, if any.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER statDteLoop(1), statNoTestinProgress(2)  

dteLedStatus 1.3.6.1.4.1.498.22.1.6.5.1
A bitwise snapshot of the front panel LED states, where 0 = LED off and 1 = LED on, as follows: LED description Octet 1 bit 7 - n/u bit 6 - n/u bit 5 - n/u bit 4 - n/u bit 3 - n/u bit 2 - DTE LMI LMI traffic on DTE bit 1 - SD EQP send data - equipment traffic bit 0 - RD EQP receive data - equipment traffic
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

dtePortStatus 1.3.6.1.4.1.498.22.1.6.5.2
A bitwise snapshot of interface port status conditions and EIA signals, where 0 = condition not present, and 1 = condition present, as follows: Octet 1 - DTE Interface Port Status bit 7 - n/u bit 6 - n/u bit 5 - n/u bit 4 - n/u bit 3 - n/u bit 2 - Transmit Activity bit 1 - Receive Activity bit 0 - DTR Loss
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

dtePortFrameCounts 1.3.6.1.4.1.498.22.1.6.5.3
The total number of frames transmitted and received on each interface port. This object will be reset to zero after a read, and after power up, soft reset, or factory defaults reset. Octet 1 - DTE Interface Transmit Frame Count Octet 2 bit 7 - 2^15 bit 7 - 2^7 bit 6 - 2^14 bit 6 - 2^6 bit 5 - 2^13 bit 5 - 2^5 bit 4 - 2^12 bit 4 - 2^4 bit 3 - 2^11 bit 3 - 2^3 bit 2 - 2^10 bit 2 - 2^2 bit 1 - 2^9 bit 1 - 2^1 bit 0 - 2^8 bit 0 - 2^0 Octet 3 - DTE Interface Receive Frame Count Octet 4 bit 7 - 2^15 bit 7 - 2^7 bit 6 - 2^14 bit 6 - 2^6 bit 5 - 2^13 bit 5 - 2^5 bit 4 - 2^12 bit 4 - 2^4 bit 3 - 2^11 bit 3 - 2^3 bit 2 - 2^10 bit 2 - 2^2 bit 1 - 2^9 bit 1 - 2^1 bit 0 - 2^8 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)