Juniper-ERX-System-MIB

File: Juniper-ERX-System-MIB.mib (77090 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IF-MIB Juniper-MIBs Juniper-TC

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 Unsigned32 TimeTicks
TEXTUAL-CONVENTION DisplayString TruthValue
DateAndTime MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP InterfaceIndexOrZero juniMibs
JuniEnable

Defined Types

JuniTimingSelector  
The system timing selector. A value of 1 corresponds to the primary timing selector. A value of 2 corresponds to the secondary timing selector. A value of 3 corresponds to the tertiary timing selector. A value of 4 indicates an error with the timing selector.
TEXTUAL-CONVENTION    
  Integer32 1..4  

JuniTimingSourceType  
The set of selectable timing source types. The timing source type determines the timing source parameters.
TEXTUAL-CONVENTION    
  INTEGER timingInterfaceIfIndex(1), timingInternal(2), timingLine(3)  

JuniTimingSourceLineType  
The set of choices for line type timing.
TEXTUAL-CONVENTION    
  INTEGER timingSourceLineUndefined(0), timingSourceLineE1PortA(1), timingSourceLineE1PortB(2), timingSourceLineT1PortA(3), timingSourceLineT1PortB(4)  

JuniSysCardType  
The type of card in a system slot: unknown Unknown type. srp Switch/Route Processor. ct3 Channelized T3. oc3 OC-3 (SONET/SDH). ut3Atm Unchannelized T3 (ATM service). ut3Frame Unchannelized T3 (Frame service). ue3Atm Unchannelized E3 (ATM service). ue3Frame Uncahnnelized E3 (Frame service). ce1 Channelized E1. ct1 Channelized T1. dpfe Dual Port Fast Ethernet. oc12Pos OC-12 (POS/SDH). oc12Atm OC-12 (ATM service). oc3Pos Quad OC-3 (POS/SDH). oc3Atm Quad OC-3 (ATM service). ge Gigabit Ethernet. fe8 Fast Ethernet 8-port. oc3oc12Pos Generic OC3/OC12 POS (multi-personality). oc3oc12Atm Generic OC3/OC12 ATM (multi-personality). coc3oc12 Channelized generic OC3/OC12 (multi-personality). coc3 Channelized OC3. coc12 Channelized OC12. oc12Server OC-12 Rate Server Card. hssi High Speed Serial Interface. geFe Generic GE/FE (multi-personality). ct3P12 Channelized T3 12-port. v35 X.21/V.35 Card. ut3f12 Unchannelized T3 12-port. ue3f12 Unchannelized E3 12-port. coc3F3 OC-3 channelized to T3. coc12F3 OC-12 channelized to T3. cocxF3 12-port T3/E3 or OC3/OC12 (multi-personality). vts Virtual Tunnel Server. oc48 OC-48 (SONET/SDH). ut3Atm4 4-port Unchannelized T3 ATM. hybrid Generic ATM/POS/GE Hybrid (multi-personality). oc3AtmGe OC3 ATM 2-port Gigabit Ethernet 1-port. oc3AtmPos OC3 ATM 2-port OC3 POS 2-port. ge2 Gigabit Ethernet 2-port.
TEXTUAL-CONVENTION    
  INTEGER unknown(0), srp(1), ct3(2), oc3(3), ut3Atm(4), ut3Frame(5), ue3Atm(6), ue3Frame(7), ce1(8), ct1(9), dpfe(10), oc12Pos(11), oc12Atm(12), oc3Pos(13), oc3Atm(14), ge(15), fe8(16), oc3oc12Pos(17), oc3oc12Atm(18), coc3oc12(19), coc3(20), coc12(21), oc12Server(22), hssi(23), geFe(24), ct3P12(25), v35(26), ut3f12(27), ue3f12(28), coc12F3(29), coc3F3(30), cocxF3(31), vts(32), oc48(33), ut3Atm4(34), hybrid(35), oc3AtmGe(36), oc3AtmPos(37), ge2(38)  

JuniERXSysTimingSelectorEntry  
SEQUENCE    
  juniERXSysTimingSelectorIndex JuniTimingSelector
  juniERXSysTimingSourceType JuniTimingSourceType
  juniERXSysTimingSourceIfIndex InterfaceIndexOrZero
  juniERXSysTimingSourceLine JuniTimingSourceLineType
  juniERXSysTimingStatus INTEGER

JuniERXSysSlotEntry  
SEQUENCE    
  juniERXSysSlotIndex Integer32
  juniERXSysSlotDescr DisplayString
  juniERXSysSlotCurrentCardType JuniSysCardType
  juniERXSysSlotRev Integer32
  juniERXSysSlotAdminStatus JuniEnable
  juniERXSysSlotOperStatus INTEGER
  juniERXSysSlotDisableReason INTEGER
  juniERXSysSlotExpectedCardType JuniSysCardType
  juniERXSysSlotControl INTEGER
  juniERXSysSlotCpuUtilPct Integer32
  juniERXSysSlotMemUtilPct Integer32
  juniERXSysSlotIoaPresent TruthValue
  juniERXSysSlotPortCount Integer32
  juniERXSysSlotLastChange TimeTicks
  juniERXSysSlotRedundancyLockout JuniEnable
  juniERXSysSlotRedundancyGroupId Unsigned32
  juniERXSysSlotSpareServer TruthValue
  juniERXSysSlotAssociatedSlot Integer32
  juniERXSysSlotRevertControl INTEGER
  juniERXSysSlotRedundancyRevertTime DateAndTime
  juniERXSysSlotBootReleaseFile DisplayString
  juniERXSysSlotBootBackupReleaseFile DisplayString
  juniERXSysSlotSerialNumber DisplayString
  juniERXSysSlotAssemblyPartNumber DisplayString
  juniERXSysSlotAssemblyRev DisplayString
  juniERXSysSlotIoaSerialNumber DisplayString
  juniERXSysSlotIoaAssemblyPartNumber DisplayString
  juniERXSysSlotIoaAssemblyRev DisplayString

JuniERXSysPortEntry  
SEQUENCE    
  juniERXSysPortIndex Integer32
  juniERXSysPortDescr DisplayString
  juniERXSysPortType INTEGER
  juniERXSysPortIfIndex InterfaceIndexOrZero

JuniERXSysPowerEntry  
SEQUENCE    
  juniERXSysPowerIndex Integer32
  juniERXSysPowerDescr DisplayString
  juniERXSysPowerStatus INTEGER

JuniERXSysTempEntry  
SEQUENCE    
  juniERXSysTempIndex Integer32
  juniERXSysTempDescr DisplayString
  juniERXSysTempStatus INTEGER
  juniERXSysTempValue Integer32

JuniERXSysSubsystemEntry  
SEQUENCE    
  juniERXSysSubsystemIndex Integer32
  juniERXSysSubsystemName DisplayString
  juniERXSysSubsystemControl INTEGER
  juniERXSysSubsystemBootReleaseFile DisplayString
  juniERXSysSubsystemBootBackupReleaseFile DisplayString

Defined Values

juniERXSysMIB 1.3.6.1.4.1.4874.2.2.17
Deprecated MIB objects for managing ERX Edge Router system elements. See the generic E-series system MIB (Juniper-System-MIB) for the preferred definitions. If both MIBs are supported, using the corresponding varbinds from both MIBs to set the same object in a single PDU is not supported.
MODULE-IDENTITY    

juniERXSysTrap 1.3.6.1.4.1.4874.2.2.17.0
OBJECT IDENTIFIER    

juniERXSysObjects 1.3.6.1.4.1.4874.2.2.17.1
OBJECT IDENTIFIER    

juniERXSysConformance 1.3.6.1.4.1.4874.2.2.17.2
OBJECT IDENTIFIER    

juniERXSysGeneral 1.3.6.1.4.1.4874.2.2.17.1.1
OBJECT IDENTIFIER    

juniERXSysFabric 1.3.6.1.4.1.4874.2.2.17.1.2
OBJECT IDENTIFIER    

juniERXSysNvs 1.3.6.1.4.1.4874.2.2.17.1.3
OBJECT IDENTIFIER    

juniERXSysSlot 1.3.6.1.4.1.4874.2.2.17.1.4
OBJECT IDENTIFIER    

juniERXSysPort 1.3.6.1.4.1.4874.2.2.17.1.5
OBJECT IDENTIFIER    

juniERXSysPower 1.3.6.1.4.1.4874.2.2.17.1.6
OBJECT IDENTIFIER    

juniERXSysTemperature 1.3.6.1.4.1.4874.2.2.17.1.7
OBJECT IDENTIFIER    

juniERXSysSubsystem 1.3.6.1.4.1.4874.2.2.17.1.8
OBJECT IDENTIFIER    

juniERXSysChassisRev 1.3.6.1.4.1.4874.2.2.17.1.1.1
Chassis revision number. If unknown, the value 255 is reported.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

juniERXSysSwVersion 1.3.6.1.4.1.4874.2.2.17.1.1.2
Currently executing operational software version.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString  

juniERXSysSwBuildDate 1.3.6.1.4.1.4874.2.2.17.1.1.3
Build date of currently executing operational software version.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString  

juniERXSysRevertControl 1.3.6.1.4.1.4874.2.2.17.1.1.4
Global revert control: off Disable global revert. immediate All slots are to revert immediately (asap). timeOfDay All slots are to revert at time specified by juniRxSysRevertTimeOfDay. This object/value must be set concurrently with juniERXSysRevertTimeOfDay.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER off(0), immediate(1), timeOfDay(2)  

juniERXSysRevertTimeOfDay 1.3.6.1.4.1.4874.2.2.17.1.1.5
The number of seconds past midnight on any given day at which time reverts are allowed to occur. This object must be set concurrently with juniERXSysRevertControl.
Status: deprecated Access: read-write
OBJECT-TYPE    
  Integer32 0..86399  

juniERXSysBootConfigControl 1.3.6.1.4.1.4874.2.2.17.1.1.6
System boot configuration control: file Revert to configuration settings specified by juniERXSysBootConfigFile. The juniERXSysBootConfigControl and juniERXSysBootConfigFile must be specified together in the same set request PDU. fileOnce Revert to configuration settings specified by juniERXSysBootConfigFile. Do not continue to use file after using it once. The juniERXSysBootConfigControl and juniERXSysBootConfigFile must be specified together in the same set request PDU. factoryDefaults Revert to factory default settings. runningConfiguration Revert to current settings.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER file(0), fileOnce(1), factoryDefaults(2), runningConfiguration(3)  

juniERXSysBootBackupConfigControl 1.3.6.1.4.1.4874.2.2.17.1.1.7
System boot backup configuration control: file Revert to backup configuration settings specified by juniERXSysBootBackupConfigFile. The juniERXSysBootBackupConfigControl and juniERXSysBootBackupConfigFile must be specified together in the same set request PDU. factoryDefaults Revert to factory default settings. none Specify no backup.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER file(0), factoryDefaults(1), none(2)  

juniERXSysBootForceBackupControl 1.3.6.1.4.1.4874.2.2.17.1.1.8
System boot force backup control: off Do not force revert to backup settings. on Do force revert to backup settings.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

juniERXSysBootAutoRevertControl 1.3.6.1.4.1.4874.2.2.17.1.1.9
System boot auto revert control: default Use default auto-revert tolerances. never Never auto-revert to backup. set Set auto-revert settings at specified tolerances.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER default(0), never(1), set(2)  

juniERXSysBootAutoRevertCountTolerance 1.3.6.1.4.1.4874.2.2.17.1.1.10
The auto-revert reboot count tolerance. This object cannot be set to zero, but may contain a zero value when the control is set to never(1).
Status: deprecated Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967294  

juniERXSysBootAutoRevertTimeTolerance 1.3.6.1.4.1.4874.2.2.17.1.1.11
The auto-revert reboot time tolerance. This object cannot be set to zero, but will contain a zero value when the control is set to never(1).
Status: deprecated Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967294  

juniERXSysBootReleaseFile 1.3.6.1.4.1.4874.2.2.17.1.1.12
The local boot release file name, with extension .rel.
Status: deprecated Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

juniERXSysBootConfigFile 1.3.6.1.4.1.4874.2.2.17.1.1.13
The local boot configuration file name, with extension .cnf. The juniERXSysBootConfigControl and juniERXSysBootConfigFile must be specified together in the same set request PDU.
Status: deprecated Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

juniERXSysBootBackupReleaseFile 1.3.6.1.4.1.4874.2.2.17.1.1.14
The local backup boot release file name, with extension .rel.
Status: deprecated Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

juniERXSysBootBackupConfigFile 1.3.6.1.4.1.4874.2.2.17.1.1.15
The local backup boot configuration file name, with extension .cnf. The juniERXSysBootBackupConfigControl and juniERXSysBootBackupConfigFile must be specified together in the same set request PDU.
Status: deprecated Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

juniERXSysAdminTimingSource 1.3.6.1.4.1.4874.2.2.17.1.1.16
The administrative timing source for the ERX system. The ERX periodically monitors the status of three timing sources, primary, secondary and tertiary. If the systems current timing source fails, the system will automatically downgrade to the next timing source. If the system is configured to automatically upgrade (juniERXSysTimingDisableAutoUpgrade is set to false(2)) the system will switch back to the higher timing source when it becomes available. A timing source failure can be detected by comparing the operational and admin timing sources. If they are not equal, the system has swapped timing sources because the administratively set value is in the error state.
Status: deprecated Access: read-write
OBJECT-TYPE    
  JuniTimingSelector  

juniERXSysOperTimingSource 1.3.6.1.4.1.4874.2.2.17.1.1.17
The operations timing source for the ERX system. The ERX periodically monitors the status of three timing sources, primary, secondary and tertiary. If the systems current timing source fails, the system will automatically downgrade to the next timing source. If the system is configured to automatically upgrade (juniERXSysTimingDisableAutoUpgrade is set to false(2)) the system will switch back to the higher timing source when it becomes available.
Status: deprecated Access: read-only
OBJECT-TYPE    
  JuniTimingSelector  

juniERXSysTimingDisableAutoUpgrade 1.3.6.1.4.1.4874.2.2.17.1.1.18
This object controls the automatic timing selector upgrade. Setting this object to true(1) will prevent automatic upgrade to the next highest timing selector. Setting this object to false(2) will enable the automatic upgrade of timing selectors.
Status: deprecated Access: read-write
OBJECT-TYPE    
  TruthValue  

juniERXSysTimingSelectorTable 1.3.6.1.4.1.4874.2.2.17.1.1.19
Table of system timing selectors.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniERXSysTimingSelectorEntry

juniERXSysTimingSelectorEntry 1.3.6.1.4.1.4874.2.2.17.1.1.19.1
A table entry describing a system timing selector.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  JuniERXSysTimingSelectorEntry  

juniERXSysTimingSelectorIndex 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.1
The system timing selector index associated with this entry.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  JuniTimingSelector  

juniERXSysTimingSourceType 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.2
The system timing source type for this entry. This object must be present when setting either the juniERXSysTimingSourceIfIndex or juniERXSysTimingSourceLine objects. Also, if the value of this object is set to timingInternal(2), no other objects should be simultanously set, otherwise the agent will return an error.
Status: deprecated Access: read-write
OBJECT-TYPE    
  JuniTimingSourceType  

juniERXSysTimingSourceIfIndex 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.3
The ifIndex of the interface selected as the system timing source. The juniERXSysTimingSourceType object must be set to timingInterfaceIfIndex(1) otherwise setting this object will fail.
Status: deprecated Access: read-write
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniERXSysTimingSourceLine 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.4
The line type timing source for this entry. The juniRxSysTimingSourceType object must be set to timingLine(3) for the agent to accept a set to this object.
Status: deprecated Access: read-write
OBJECT-TYPE    
  JuniTimingSourceLineType  

juniERXSysTimingStatus 1.3.6.1.4.1.4874.2.2.17.1.1.19.1.5
The status associated with this system timing selector.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER timingStatusOk(1), timingStatusError(2), timingStatusUnknown(3)  

juniERXSysMemUtilPct 1.3.6.1.4.1.4874.2.2.17.1.1.20
Percentage of system memory utilization. A value of -1 indicates the utilization is unknown.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

juniERXSysMemCapacity 1.3.6.1.4.1.4874.2.2.17.1.1.21
The total memory capacity of the system. Negative values are returned when the capacity exceeds 2147483647; interpret the negative 32-bit integer as an unsigned 32-bit integer value.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32  

juniERXSysHighMemUtilThreshold 1.3.6.1.4.1.4874.2.2.17.1.1.22
The value of system memory utilization, where if reached for the first time will generate a high memory utilization event to the management entity on this system. The value of this object must be greated than the value of juniERXSysAbatedMemUtilThreshold.
Status: deprecated Access: read-write
OBJECT-TYPE    
  Integer32 1..100  

juniERXSysAbatedMemUtilThreshold 1.3.6.1.4.1.4874.2.2.17.1.1.23
The value of system memory utilization that is used to determine when to generate an abated memory utilization event notification to the management entity on this system. The value of this object must be less than the value of juniERXSysHighMemUtilThreshold. The abated memory utilization trap is sent once if the high memory threshold was reached, and memory utilization falls to the value of this object.
Status: deprecated Access: read-write
OBJECT-TYPE    
  Integer32 0..99  

juniERXSysMemUtilTrapEnable 1.3.6.1.4.1.4874.2.2.17.1.1.24
Controls the sending of system memory utilization events. Setting the value of this object to true(1) will cause system memory utilization event notification, if they occur, to be sent to the management entity on this system. Setting the value of this object to false(2) will disable event notifications.
Status: deprecated Access: read-write
OBJECT-TYPE    
  TruthValue  

juniERXSysGeneralTrapEnable 1.3.6.1.4.1.4874.2.2.17.1.1.25
Controls whether a member of the set of ERX system notifications (traps) defined in this MIB or the counterpart notifications defined in the generic E-series system MIB (Juniper-System-MIB) will be initiated when the appropriate system event occures. Setting the value of this object to true(1) will enable the event notifications from this MIB, if they occur, to be sent to the management entity on this system, provided no other restrictions are in effect, instead of the counterparts from the generic system MIB. Setting the value of this object to false(2) will disable all event notifications defined in this MIB, enabling the ones from the generic system MIB.
Status: deprecated Access: read-write
OBJECT-TYPE    
  TruthValue  

juniERXSysFabricSpeed 1.3.6.1.4.1.4874.2.2.17.1.2.1
Speed of switching fabric, in gigabits per second.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32  

juniERXSysFabricRev 1.3.6.1.4.1.4874.2.2.17.1.2.2
Fabric revision number. If unknown, the value 255 is reported.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

juniERXSysNvsStatus 1.3.6.1.4.1.4874.2.2.17.1.3.1
Status of non-volatile storage (NVS): notPresent NVS is not installed. writeProtected NVS is write-protected. volumeError Status poll of NVS failed. nearCapacity Utilization exceeds 85% of NVS capacity. ok NVS is operational, none of the preceding conditions apply. nearConfigCapacity Utilization exceeds the ability to save the running configuration.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(0), writeProtected(1), volumeError(2), nearCapacity(3), ok(4), nearConfigCapacity(5)  

juniERXSysNvsCapacity 1.3.6.1.4.1.4874.2.2.17.1.3.2
Capacity of NVS storage in megabytes.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32  

juniERXSysNvsUtilPct 1.3.6.1.4.1.4874.2.2.17.1.3.3
Percentage of NVS storage used. A value of -1 indicates NVS utilization is unknown.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

juniERXSysSlotCount 1.3.6.1.4.1.4874.2.2.17.1.4.1
The number of slots in the system.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32  

juniERXSysSlotTable 1.3.6.1.4.1.4874.2.2.17.1.4.2
Table of system slots.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniERXSysSlotEntry

juniERXSysSlotEntry 1.3.6.1.4.1.4874.2.2.17.1.4.2.1
A table entry describing contents of a system slot.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  JuniERXSysSlotEntry  

juniERXSysSlotIndex 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.1
Slot number. NOTE: Slot numbers are zero-based.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  Integer32 0..255  

juniERXSysSlotDescr 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.2
Textual description of the card.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

juniERXSysSlotCurrentCardType 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.3
Type of card actually in the slot. This could be different from the type reported in juniERXSysSlotExpectedCardType, in which case it may be necessary to set juniERXSysSlotControl to 'flush' before this card can be made operational.
Status: deprecated Access: read-only
OBJECT-TYPE    
  JuniSysCardType  

juniERXSysSlotRev 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.4
Revision number of the card. If unknown, the value 255 is reported.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

juniERXSysSlotAdminStatus 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.5
Exerts administrative control to enable/disable the slot.
Status: deprecated Access: read-write
OBJECT-TYPE    
  JuniEnable  

juniERXSysSlotOperStatus 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.6
Status of the card.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), empty(1), disabled(2), failed(3), booting(4), initializing(5), online(6), standby(7), inactive(8)  

juniERXSysSlotDisableReason 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.7
Indicates the condition causing the slot to be disabled: none Value when card is not disabled. unknown Unknown reason for disablement. assessing The slot content is being assessed (transient initialization state). admin The slot is administratively disabled. cardMismatch The current card type conflicts with configuration associated with a different card type that previously occupied the slot. fabricLimit Card resource requirements exceed available fabric capacity. imageError Software image for card is missing or invalid.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER none(0), unknown(1), assessing(2), admin(3), cardMismatch(4), fabricLimit(5), imageError(6)  

juniERXSysSlotExpectedCardType 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.8
Type of card associated with this slot through prior presence. After the card is removed, this association persists (and inhibits operation of a different card type in this slot, if one is inserted) until juniERXSysSlotControl is set to 'flush'.
Status: deprecated Access: read-only
OBJECT-TYPE    
  JuniSysCardType  

juniERXSysSlotControl 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.9
Administrative control of this slot: noOperation Setting this value has no effect. flush Flushes configuration associated with a card type that previously occupied this slot. Used to explicitly confirm that the slot is now empty, or contains a different card type. Card must be disabled when this value is asserted. See description for juniERXSysSlotDisableReason. reset Resets the slot. forceFailover Forces the slot to failover to backup. noBoot Deconfigure primary release file for the slot. noBootBackup Deconfigure backup release file for the slot.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(0), flush(1), reset(2), forceFailover(3), noBoot(4), noBootBackup(5)  

juniERXSysSlotCpuUtilPct 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.10
Percentage of CPU utilization. A value of -1 indicates the utilization is unknown.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

juniERXSysSlotMemUtilPct 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.11
Percentage of memory utilization. A value of -1 indicates the utilization is unknown.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

juniERXSysSlotIoaPresent 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.12
Indicates whether the card's corresponding I/O adapter is present.
Status: deprecated Access: read-only
OBJECT-TYPE    
  TruthValue  

juniERXSysSlotPortCount 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.13
Number of physical ports for the EXPECTED card type for this slot. NOTE: In event of a card mismatch in this slot, the port count for the CURRENT card in this slot is not recognized/reported until the configuration for the EXPECTED card is explicitly flushed via juniERXSysSlotControl.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32  

juniERXSysSlotLastChange 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.14
The value of sysUpTime when the value of juniERXSysSlotOperStatus last changed.
Status: deprecated Access: read-only
OBJECT-TYPE    
  TimeTicks  

juniERXSysSlotRedundancyLockout 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.15
Exerts administrative control to enable/disable Redundancy protection for the slot.
Status: deprecated Access: read-write
OBJECT-TYPE    
  JuniEnable  

juniERXSysSlotRedundancyGroupId 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.16
Identifies the Redundancy group as derived from hardware settings.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniERXSysSlotSpareServer 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.17
True only if the line card in slot is a spare redundant server.
Status: deprecated Access: read-only
OBJECT-TYPE    
  TruthValue  

juniERXSysSlotAssociatedSlot 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.18
If the module is a primary card and the spare is acting on its behalf, then the value of this object is the slot number of the associated spare. If the module is a primary card and is active (not spared), then the value of this object is the cards actual slot number. If the module is a spare card and it is active, then the value of this object is the slot number of the primary card that is being spared for. If the module is a spare and it is inactive, then the value of this object is the its own slot number. If module is not part of a redundancy group, or the slot is empty, the value of this object is 255.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32  

juniERXSysSlotRevertControl 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.19
Per-slot revert control: off Disable slot revert. immediate Slot is to revert immediately (asap). timeAndDate Slot is to revert at time specified by juniRxSysSlotRedundancyRevertTime.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER off(0), immediate(1), timeAndDate(2)  

juniERXSysSlotRedundancyRevertTime 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.20
The date and time associated with the timeAndDate (delayed) revert operation.
Status: deprecated Access: read-write
OBJECT-TYPE    
  DateAndTime  

juniERXSysSlotBootReleaseFile 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.21
The local boot release file name for this slot, with extension .rel.
Status: deprecated Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

juniERXSysSlotBootBackupReleaseFile 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.22
The local backup boot release file name for this slot, with extension .rel.
Status: deprecated Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

juniERXSysSlotSerialNumber 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.23
The serial number of the card in this slot.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

juniERXSysSlotAssemblyPartNumber 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.24
The part number of the card in this slot.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

juniERXSysSlotAssemblyRev 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.25
The revision number of the card assembly in this slot.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..3)  

juniERXSysSlotIoaSerialNumber 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.26
The serial number of the I/O adaptor on the card in this slot.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

juniERXSysSlotIoaAssemblyPartNumber 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.27
The part number of the I/O adaptor on the card in this slot.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

juniERXSysSlotIoaAssemblyRev 1.3.6.1.4.1.4874.2.2.17.1.4.2.1.28
The revision number of the I/O adaptor assembly on the card in this slot.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..3)  

juniERXSysPortTable 1.3.6.1.4.1.4874.2.2.17.1.5.1
Table of system physical ports. The information in this table reflects the ports for the EXPECTED card type in each slot; in event of a card mismatch, this table permits navigation of the existing configuration of the expected card type.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniERXSysPortEntry

juniERXSysPortEntry 1.3.6.1.4.1.4874.2.2.17.1.5.1.1
A table entry describing a physical port of the system.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  JuniERXSysPortEntry  

juniERXSysPortIndex 1.3.6.1.4.1.4874.2.2.17.1.5.1.1.1
Port number of this physical port, relative to the slot in which it resides. Each physical port is uniquely distinguished by its slot/port pair. NOTE: Port numbers are zero-based.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  Integer32 0..255  

juniERXSysPortDescr 1.3.6.1.4.1.4874.2.2.17.1.5.1.1.2
Textual description of this port.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

juniERXSysPortType 1.3.6.1.4.1.4874.2.2.17.1.5.1.1.3
Type of the physical port: unknown Unknown port type. eth Ethernet. ct3 Channelized T3. oc3c OC-3c (SONET/SDH). ut3Atm Unchannelized T3 (ATM service). ut3Frame Unchannelized T3 (Frame service). ue3Atm Unchannelized E3 (ATM service). ue3Frame Unchannelized E3 (Frame service). ce1 Channelized E1. ct1 Channelized T1. oc12cPos OC-12c (POS/SDH). oc12cAtm OC-12c (ATM service). oc3cPos OC-3c (POS/SDH). oc3cAtm OC-3c (ATM service). coc3 Channelized OC-3. coc12 Channelized OC-12. server Tunnel Server (no physical ports). hssi High Speed Serial Interface. v35 X.21/V.35. oc48cPos OC-48c (POS/SDH).
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), eth(1), ct3(2), oc3c(3), ut3Atm(4), ut3Frame(5), ue3Atm(6), ue3Frame(7), ce1(8), ct1(9), oc12cPos(10), oc12cAtm(11), oc3cPos(12), oc3cAtm(13), coc3(14), coc12(15), server(16), hssi(17), v35(18), oc48cPos(19)  

juniERXSysPortIfIndex 1.3.6.1.4.1.4874.2.2.17.1.5.1.1.4
The ifIndex of the Interfaces MIB ifTable entry corresponding to this physical port; if zero, the ifIndex is unknown or does not exist.
Status: deprecated Access: read-only
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniERXSysPowerTable 1.3.6.1.4.1.4874.2.2.17.1.6.1
Table of system power elements.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniERXSysPowerEntry

juniERXSysPowerEntry 1.3.6.1.4.1.4874.2.2.17.1.6.1.1
A table entry describing status of a system power element.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  JuniERXSysPowerEntry  

juniERXSysPowerIndex 1.3.6.1.4.1.4874.2.2.17.1.6.1.1.1
Arbitrary integer index to distinguish entries in this table.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  Integer32 0..255  

juniERXSysPowerDescr 1.3.6.1.4.1.4874.2.2.17.1.6.1.1.2
Textual description of this power element.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

juniERXSysPowerStatus 1.3.6.1.4.1.4874.2.2.17.1.6.1.1.3
The status of the power element: inactive No power available from this element. active Power available from this element.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER inactive(0), active(1)  

juniERXSysTempFanStatus 1.3.6.1.4.1.4874.2.2.17.1.7.1
Status of fan subsystem. ok All components operational warning The fan subsystem has a non-critical failure. failed The fan subsystem has a critical failure, or has been removed, and is now non-operational.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER failed(0), ok(1), warning(2)  

juniERXSysTempTable 1.3.6.1.4.1.4874.2.2.17.1.7.2
Table of system temperature sensors. Sensors are distributed across the chassis, at least one sensor per populated slot.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniERXSysTempEntry

juniERXSysTempEntry 1.3.6.1.4.1.4874.2.2.17.1.7.2.1
A table entry describing status of a temperature sensor.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  JuniERXSysTempEntry  

juniERXSysTempIndex 1.3.6.1.4.1.4874.2.2.17.1.7.2.1.1
Arbitrary integer index to distinguish sensors associated with the same chassis slot.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  Integer32 0..255  

juniERXSysTempDescr 1.3.6.1.4.1.4874.2.2.17.1.7.2.1.2
Textual description of this sensor.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..63)  

juniERXSysTempStatus 1.3.6.1.4.1.4874.2.2.17.1.7.2.1.3
The status of a temperature sensor: unknown unknown failed failed tooLow below nominal range nominal within nominal range tooHigh above nominal range tooLowWarning near lower limit tooHighWarning near upper limit
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), failed(1), tooLow(2), nominal(3), tooHigh(4), tooLowWarning(5), tooHighWarning(6)  

juniERXSysTempValue 1.3.6.1.4.1.4874.2.2.17.1.7.2.1.4
The temperature measured by this sensor in degrees Celsius. This measurement is valid only if the value of the corresponding juniERXSysTempStatus is nominal.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32  

juniERXSysTempProtectionStatus 1.3.6.1.4.1.4874.2.2.17.1.7.3
Thermal protection status: monitoring monitoring inHoldOff hold off time has begun activatedHoldOffExpired hold off time has expired, the system is in thermal protection mode activatedTempTooHigh temperature too high, the system is in thermal protection mode
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER monitoring(1), inHoldOff(2), activatedHoldOffExpired(3), activatedTempTooHigh(4)  

juniERXSysTempProtectionHoldOffTime 1.3.6.1.4.1.4874.2.2.17.1.7.4
The time, in seconds, before the system enters thermal protection mode after a critical fan subsystem failure is detected.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 0..1200  

juniERXSysTempProtectionHoldOffTimeRemaining 1.3.6.1.4.1.4874.2.2.17.1.7.5
The time remaining, in seconds, before the system enters thermal protection mode while the thermal protection status is set to inHoldOff. The value decrements every second until it reaches zero, and the status changes to activatedHoldOffExpired. When the thermal protection status is not inHoldOff or activatedHoldOffExpired, the value is set to the hold off time.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 0..1200  

juniERXSysSubsystemTable 1.3.6.1.4.1.4874.2.2.17.1.8.1
Table of subsystems.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniERXSysSubsystemEntry

juniERXSysSubsystemEntry 1.3.6.1.4.1.4874.2.2.17.1.8.1.1
A table entry containing information pertaining to a subsystem.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  JuniERXSysSubsystemEntry  

juniERXSysSubsystemIndex 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.1
Subsystem number.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  Integer32 0..255  

juniERXSysSubsystemName 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.2
The name of the subsystem.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..128)  

juniERXSysSubsystemControl 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.3
Administrative control of this subsystem: noOperation Setting this value has no effect. noBoot Deconfigure primary release file for the subsystem. noBootBackup Deconfigure backup release file for the subsystem.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(0), noBoot(1), noBootBackup(2)  

juniERXSysSubsystemBootReleaseFile 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.4
The local boot release file name for this subsystem, with extension .rel.
Status: deprecated Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

juniERXSysSubsystemBootBackupReleaseFile 1.3.6.1.4.1.4874.2.2.17.1.8.1.1.5
The local backup boot release file name for this subsystem, with extension .rel.
Status: deprecated Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

juniERXSysSlotOperStatusChange 1.3.6.1.4.1.4874.2.2.17.0.1
Reports a status change for a slot. This trap is generated on a transition into a stable state (online or disabled) or on a transition out of online.
Status: deprecated Access: read-write
NOTIFICATION-TYPE    

juniERXSysPowerStatusChange 1.3.6.1.4.1.4874.2.2.17.0.2
Reports a change in the status of a power element.
Status: deprecated Access: read-write
NOTIFICATION-TYPE    

juniERXSysTempFanStatusChange 1.3.6.1.4.1.4874.2.2.17.0.3
Reports a transition between the three states of the fan subsystem. When the fan subsystem transitions to the failed state the thermal protection hold off time begins.
Status: deprecated Access: read-write
NOTIFICATION-TYPE    

juniERXSysTempStatusChange 1.3.6.1.4.1.4874.2.2.17.0.4
Reports a change in the temperature status. When the status transitions to the tooHigh state the system enters thermal protection mode.
Status: deprecated Access: read-write
NOTIFICATION-TYPE    

juniERXSysHighMemUtil 1.3.6.1.4.1.4874.2.2.17.0.5
Report system memory utilization has met the conditions of juniERXSysHighMemUtilThreshold.
Status: deprecated Access: read-write
NOTIFICATION-TYPE    

juniERXSysAbatedMemUtil 1.3.6.1.4.1.4874.2.2.17.0.6
Reports system memory utilization has met the conditions of juniERXSysAbatedMemUtilThreshold.
Status: deprecated Access: read-write
NOTIFICATION-TYPE    

juniERXSysTempProtectionStatusChange 1.3.6.1.4.1.4874.2.2.17.0.7
Notification about changes in the state of Thermal Protection. This notification is sent when the tempProtectionStatus changes. It is also sent when the holdOffTimeRemaining is 50% of the holdOffTime.
Status: deprecated Access: read-write
NOTIFICATION-TYPE    

juniERXSysCompliances 1.3.6.1.4.1.4874.2.2.17.2.1
OBJECT IDENTIFIER    

juniERXSysGroups 1.3.6.1.4.1.4874.2.2.17.2.2
OBJECT IDENTIFIER    

juniERXSysCompliance 1.3.6.1.4.1.4874.2.2.17.2.1.1
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when new slot information objects were added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniERXSysCompliance1 1.3.6.1.4.1.4874.2.2.17.2.1.2
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when the timing group was added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniERXSysCompliance2 1.3.6.1.4.1.4874.2.2.17.2.1.3
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when new memory information objects and notifications were added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniERXSysCompliance3 1.3.6.1.4.1.4874.2.2.17.2.1.4
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when new system temperature information objects and notifications were added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniERXSysCompliance4 1.3.6.1.4.1.4874.2.2.17.2.1.5
Obsolete compliance statement for entities which implement the ERX System MIB. This compliance statement became obsolete when the general trap control object was added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniERXSysCompliance5 1.3.6.1.4.1.4874.2.2.17.2.1.6
The compliance statement for entities which implement the ERX System MIB.
Status: deprecated Access: read-write
MODULE-COMPLIANCE    

juniERXSysGroup 1.3.6.1.4.1.4874.2.2.17.2.2.1
Obsolete collection of management objects pertaining to system capabilities in a Juniper product. This group became obsolete when new slot information objects were added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniERXSysNotifyGroup 1.3.6.1.4.1.4874.2.2.17.2.2.2
Obsolete collection of management notifications pertaining to system operations in a Juniper product. This group became obsolete when new memory threshold notificaitons were added.
Status: obsolete Access: read-write
NOTIFICATION-GROUP    

juniERXSysGeneralGroup 1.3.6.1.4.1.4874.2.2.17.2.2.3
Obsolete collection of management objects pertaining to general system capabilities in a Juniper product. This group became obsolete when new memory management objects were added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniERXSysFabricGroup 1.3.6.1.4.1.4874.2.2.17.2.2.4
A collection of management objects pertaining to system fabric capabilities in a Juniper product.
Status: deprecated Access: read-write
OBJECT-GROUP    

juniERXSysNvsGroup 1.3.6.1.4.1.4874.2.2.17.2.2.5
A collection of management objects pertaining to non-volitile storage subsystem capabilities in a Juniper product.
Status: deprecated Access: read-write
OBJECT-GROUP    

juniERXSysSlotGroup 1.3.6.1.4.1.4874.2.2.17.2.2.6
A collection of management objects pertaining to slot-specific system capabilities in a Juniper product.
Status: deprecated Access: read-write
OBJECT-GROUP    

juniERXSysPortGroup 1.3.6.1.4.1.4874.2.2.17.2.2.7
A collection of management objects pertaining to port-related system capabilities in a Juniper product.
Status: deprecated Access: read-write
OBJECT-GROUP    

juniERXSysPowerGroup 1.3.6.1.4.1.4874.2.2.17.2.2.8
A collection of management objects pertaining to the power subsystem capabilities in a Juniper product.
Status: deprecated Access: read-write
OBJECT-GROUP    

juniERXSysTemperatureGroup 1.3.6.1.4.1.4874.2.2.17.2.2.9
Obsolete collection of management objects pertaining to system temperature monitoring capabilities in a Juniper product. This group became obsolete when temperature shutdown parameters were added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniERXSysSubsystemGroup 1.3.6.1.4.1.4874.2.2.17.2.2.10
A collection of management objects pertaining to subsystem capabilities in a Juniper product.
Status: deprecated Access: read-write
OBJECT-GROUP    

juniERXSysTimingGroup 1.3.6.1.4.1.4874.2.2.17.2.2.11
A collection of management objects pertaining to system timing capabilities in a Juniper product.
Status: deprecated Access: read-write
OBJECT-GROUP    

juniERXSysGeneralGroup2 1.3.6.1.4.1.4874.2.2.17.2.2.12
Obsolete collection of management objects pertaining to general system capabilities in a Juniper product. This group became obsolete when the general trap control object was added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniERXSysNotifyGroup2 1.3.6.1.4.1.4874.2.2.17.2.2.13
Obsolete collection of management notifications pertaining to system operations in a Juniper product. This group became obsolete when the tempProtectionStatusChange notification was added.
Status: obsolete Access: read-write
NOTIFICATION-GROUP    

juniERXSysTemperatureGroup2 1.3.6.1.4.1.4874.2.2.17.2.2.14
A collection of management objects pertaining to system temperature monitoring capabilities in a Juniper product.
Status: deprecated Access: read-write
OBJECT-GROUP    

juniERXSysNotifyGroup3 1.3.6.1.4.1.4874.2.2.17.2.2.15
A collection of management notifications pertaining to system operations in a Juniper product.
Status: deprecated Access: read-write
NOTIFICATION-GROUP    

juniERXSysGeneralGroup3 1.3.6.1.4.1.4874.2.2.17.2.2.16
A collection of management objects pertaining to general system capabilities in a Juniper product.
Status: deprecated Access: read-write
OBJECT-GROUP