juniES2Registry |
1.3.6.1.4.1.4874.4.2.3 |
Juniper second generation E-series product family system-specific
object identification values. This module defines AutonomousType (OID)
values for all the physical entity types (entPhysicalVendorType). This
module will be updated whenever a new type of module or other hardware
becomes available in second generation E-series systems. |
MODULE-IDENTITY |
|
|
|
es2Chassis |
1.3.6.1.4.1.4874.4.2.3.1.1 |
The vendor type ID for a second generation E-series chassis. This
identifies an 'overall' physical entity for any second generation
E-series system. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e320BaseChassis |
1.3.6.1.4.1.4874.4.2.3.1.1.1 |
E320 base chassis with 12 slots for line modules - includes chassis,
midplane, DC PDU, and fan tray. The E320 system uses a carrier-class
design with a passive midplane, active front-insert line modules(LM)
and rear-insert input/output adapters(IOA). |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e120BaseChassis |
1.3.6.1.4.1.4874.4.2.3.1.1.2 |
E120 base chassis with 6 slots for line modules - includes chassis,
midplane, DC PDU, and fan tray. The E120 system uses a carrier-class
design with a passive midplane, active front-insert line modules(LM)
and rear-insert input/output adapters(IOA). |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2FanAssembly |
1.3.6.1.4.1.4874.4.2.3.1.2 |
The vendor type ID for a second generation E-series fan assembly. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e320PrimaryFanTray |
1.3.6.1.4.1.4874.4.2.3.1.2.1 |
E320 fan tray with 8 fans. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e320AuxiliaryFanTray |
1.3.6.1.4.1.4874.4.2.3.1.2.2 |
E320 fan tray with 8 fans. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e120PrimaryFanTray |
1.3.6.1.4.1.4874.4.2.3.1.2.3 |
E120 fan tray with 9 fans. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e320DcPowerDistributionUnit |
1.3.6.1.4.1.4874.4.2.3.1.3.1 |
E320 DC power distribution unit (PDU). |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2Midplane |
1.3.6.1.4.1.4874.4.2.3.1.4 |
The vendor type ID for a second generation E-series midplane. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e320Midplane |
1.3.6.1.4.1.4874.4.2.3.1.4.1 |
E320 chassis midplane. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e120Midplane |
1.3.6.1.4.1.4874.4.2.3.1.4.2 |
E120 chassis midplane. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2SrpModule |
1.3.6.1.4.1.4874.4.2.3.1.5 |
The vendor type ID for a second generation E-series system controller/
switch fabric module. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e320Srp100 |
1.3.6.1.4.1.4874.4.2.3.1.5.1 |
E320 100Gb SRP - The Switch Route Processor (SRP)
is responsible for running the routing protocols as well as
overall system control. The SRP also contains a switch fabric
slice that is responsible for packet forwarding. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e320Srp320 |
1.3.6.1.4.1.4874.4.2.3.1.5.2 |
E320 320Gb SRP - The Switch Route Processor (SRP)
is responsible for running the routing protocols as well as
overall system control. The SRP also contains a switch fabric
slice that is responsible for packet forwarding. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e120Srp120 |
1.3.6.1.4.1.4874.4.2.3.1.5.3 |
E120 120Gb SRP - The Switch Route Processor (SRP)
is responsible for running the routing protocols as well as
overall system control. The SRP also contains a switch fabric
slice that is responsible for packet forwarding. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2SwitchFabricModule |
1.3.6.1.4.1.4874.4.2.3.1.6 |
The vendor type ID for a second generation E-series switch fabric
module. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e320Sfm100 |
1.3.6.1.4.1.4874.4.2.3.1.6.1 |
E320 100Gb switch fabric module. The SFM functions include buffer
management, queuing, scheduling and packet processing. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e320Sfm320 |
1.3.6.1.4.1.4874.4.2.3.1.6.2 |
E320 320Gb switch fabric module. The SFM functions include buffer
management, queuing, scheduling and packet processing. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e120Sfm120 |
1.3.6.1.4.1.4874.4.2.3.1.6.3 |
E120 120Gb switch fabric module. The SFM functions include buffer
management, queuing, scheduling and packet processing. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2SrpIoa |
1.3.6.1.4.1.4874.4.2.3.1.7 |
The vendor type ID for the system controller I/O adapter for a second
generation E-series system. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
e320SrpIoa |
1.3.6.1.4.1.4874.4.2.3.1.7.1 |
E320 SRP IOA. This card provides clocking functions as well as
management and alarm interfaces. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2ForwardingModule |
1.3.6.1.4.1.4874.4.2.3.1.8 |
The vendor type ID for a second generation E-series forwarding module. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2Lm4 |
1.3.6.1.4.1.4874.4.2.3.1.8.1 |
E320 4Gb (series 1) line module. This Line Module supports both
uplink and customer facing IOAs and is responsible for
processing data traffic. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2Lm10Uplink |
1.3.6.1.4.1.4874.4.2.3.1.8.2 |
E320 10Gb (series 2) uplink line module. This Line Module is
primarily focused on uplink IOAs and is responsible for
processing data traffic. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2Lm10 |
1.3.6.1.4.1.4874.4.2.3.1.8.3 |
E320 10Gb (series 3) line module. This Line Module supports
both uplink and customer facing IOAs and is responsible for
processing data traffic. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2Lm10s |
1.3.6.1.4.1.4874.4.2.3.1.8.4 |
E320 10Gb (series 4) line module. This Line Module supports
both uplink and customer facing IOAs and is responsible for
processing data traffic. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2ForwardingIoa |
1.3.6.1.4.1.4874.4.2.3.1.9 |
The vendor type ID for a second generation E-series I/O adapter for a
forwarding module. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2Ge4S1Ioa |
1.3.6.1.4.1.4874.4.2.3.1.9.1 |
E320 GE-4 IOA. This is a series 1, half-height, single wide IOA
with 4 physical interfaces that require pluggable GE interfaces. This
IOA uses the full capacity of a Series 1 line module. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2Oc48Stm16PosS1Ioa |
1.3.6.1.4.1.4874.4.2.3.1.9.2 |
E320 OC48/STM16 POS IOA. This is a series 1, half-height,
single wide IOA with 1 physical interface that requires a pluggable
OC48/STM16 interface. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2ServiceS1Ioa |
1.3.6.1.4.1.4874.4.2.3.1.9.3 |
E320 service IOA. This is a series 1, full-height, single
wide IOA and does not support any physical interfaces. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2Oc3Stm1x8AtmS1Ioa |
1.3.6.1.4.1.4874.4.2.3.1.9.4 |
E320 OC3/STM1-8 ATM IOA. This is a series 1, half-height,
single wide IOA that supports 8 physical interfaces that require
pluggable OC3/STM1 interfaces. This IOA can be combined with other
half-height IOAs (except those that use the full capacity of a slot's
bandwidth such as the GE-4 IOA). |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2RedundancyS1Ioa |
1.3.6.1.4.1.4874.4.2.3.1.9.5 |
E320 redundancy IOA. This is a series 1, full-height, single
wide IOA and does not support any physical interfaces. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2Oc12Stm4x2PosS1Ioa |
1.3.6.1.4.1.4874.4.2.3.1.9.6 |
E320 OC12/STM4-2 POS IOA. This is a series 1, half-height,
single wide IOA that supports 2 physical interfaces that require
pluggable OC12/STM4 interfaces. This IOA can be combined with other
half-height IOAs (except those that use the full capacity
of a slot's bandwidth such as the GE-4 IOA). |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2Oc12Stm4x2AtmS1Ioa |
1.3.6.1.4.1.4874.4.2.3.1.9.7 |
E320 OC12/STM4-2 ATM IOA. This is a series 1, half-height,
single wide IOA that supports 2 physical interfaces that require
pluggable OC12/STM4 interfaces. This IOA can be combined with other
half-height IOAs (except those that use the full capacity
of a slot's bandwidth such as the GE-4 IOA). |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2dash10GeS1Ioa |
1.3.6.1.4.1.4874.4.2.3.1.9.8 |
E320 10GE IOA. This is a series 1, full-height, single wide
IOA that supports 2 physical interface that requires a pluggable
10GE interface. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2Ge8S1Ioa |
1.3.6.1.4.1.4874.4.2.3.1.9.9 |
E320 GE-8 IOA. This is a series 1, half-height, single wide IOA
that supports 8 physical interfaces that require pluggable GE
transceivers. This IOA will support a configuration of 8 active
or 4 active + 4 standby interfaces. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2dash10GePrS2Ioa |
1.3.6.1.4.1.4874.4.2.3.1.9.10 |
E320 10GE IOA with port redundancy (PR). This is a series 2,
full-height, single wide IOA that supports 2 physical
interfaces (1 active + 1 standby) that require pluggable 10GE
transceivers. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
es2Ge20S2Ioa |
1.3.6.1.4.1.4874.4.2.3.1.9.11 |
E320 GE-20 IOA. This is a series 2, full-height, single wide IOA
that supports 20 physical interfaces that require pluggable GE
transceivers. This IOA will support a configuration of 20 active
or 10 active + 10 standby interfaces. |
Status: current |
Access: read-only |