Juniper-ES2-Registry

File: Juniper-ES2-Registry.mib (14594 bytes)

Imported modules

SNMPv2-SMI Juniper-Registry

Imported symbols

MODULE-IDENTITY OBJECT-IDENTITY juniAdmin

Defined Values

juniES2Registry 1.3.6.1.4.1.4874.4.2.3
Juniper second generation E-series product family system-specific object identification values. This module defines AutonomousType (OID) values for all the physical entity types (entPhysicalVendorType). This module will be updated whenever a new type of module or other hardware becomes available in second generation E-series systems.
MODULE-IDENTITY    

juniES2EntPhysicalType 1.3.6.1.4.1.4874.4.2.3.1
OBJECT IDENTIFIER    

es2Chassis 1.3.6.1.4.1.4874.4.2.3.1.1
The vendor type ID for a second generation E-series chassis. This identifies an 'overall' physical entity for any second generation E-series system.
Status: current Access: read-only
OBJECT-IDENTITY    

e320BaseChassis 1.3.6.1.4.1.4874.4.2.3.1.1.1
E320 base chassis with 12 slots for line modules - includes chassis, midplane, DC PDU, and fan tray. The E320 system uses a carrier-class design with a passive midplane, active front-insert line modules(LM) and rear-insert input/output adapters(IOA).
Status: current Access: read-only
OBJECT-IDENTITY    

e120BaseChassis 1.3.6.1.4.1.4874.4.2.3.1.1.2
E120 base chassis with 6 slots for line modules - includes chassis, midplane, DC PDU, and fan tray. The E120 system uses a carrier-class design with a passive midplane, active front-insert line modules(LM) and rear-insert input/output adapters(IOA).
Status: current Access: read-only
OBJECT-IDENTITY    

es2FanAssembly 1.3.6.1.4.1.4874.4.2.3.1.2
The vendor type ID for a second generation E-series fan assembly.
Status: current Access: read-only
OBJECT-IDENTITY    

e320PrimaryFanTray 1.3.6.1.4.1.4874.4.2.3.1.2.1
E320 fan tray with 8 fans.
Status: current Access: read-only
OBJECT-IDENTITY    

e320AuxiliaryFanTray 1.3.6.1.4.1.4874.4.2.3.1.2.2
E320 fan tray with 8 fans.
Status: current Access: read-only
OBJECT-IDENTITY    

e120PrimaryFanTray 1.3.6.1.4.1.4874.4.2.3.1.2.3
E120 fan tray with 9 fans.
Status: current Access: read-only
OBJECT-IDENTITY    

es2PowerInput 1.3.6.1.4.1.4874.4.2.3.1.3
The vendor type ID for a second generation E-series power distribution module.
Status: current Access: read-only
OBJECT-IDENTITY    

e320DcPowerDistributionUnit 1.3.6.1.4.1.4874.4.2.3.1.3.1
E320 DC power distribution unit (PDU).
Status: current Access: read-only
OBJECT-IDENTITY    

es2Midplane 1.3.6.1.4.1.4874.4.2.3.1.4
The vendor type ID for a second generation E-series midplane.
Status: current Access: read-only
OBJECT-IDENTITY    

e320Midplane 1.3.6.1.4.1.4874.4.2.3.1.4.1
E320 chassis midplane.
Status: current Access: read-only
OBJECT-IDENTITY    

e120Midplane 1.3.6.1.4.1.4874.4.2.3.1.4.2
E120 chassis midplane.
Status: current Access: read-only
OBJECT-IDENTITY    

es2SrpModule 1.3.6.1.4.1.4874.4.2.3.1.5
The vendor type ID for a second generation E-series system controller/ switch fabric module.
Status: current Access: read-only
OBJECT-IDENTITY    

e320Srp100 1.3.6.1.4.1.4874.4.2.3.1.5.1
E320 100Gb SRP - The Switch Route Processor (SRP) is responsible for running the routing protocols as well as overall system control. The SRP also contains a switch fabric slice that is responsible for packet forwarding.
Status: current Access: read-only
OBJECT-IDENTITY    

e320Srp320 1.3.6.1.4.1.4874.4.2.3.1.5.2
E320 320Gb SRP - The Switch Route Processor (SRP) is responsible for running the routing protocols as well as overall system control. The SRP also contains a switch fabric slice that is responsible for packet forwarding.
Status: current Access: read-only
OBJECT-IDENTITY    

e120Srp120 1.3.6.1.4.1.4874.4.2.3.1.5.3
E120 120Gb SRP - The Switch Route Processor (SRP) is responsible for running the routing protocols as well as overall system control. The SRP also contains a switch fabric slice that is responsible for packet forwarding.
Status: current Access: read-only
OBJECT-IDENTITY    

es2SwitchFabricModule 1.3.6.1.4.1.4874.4.2.3.1.6
The vendor type ID for a second generation E-series switch fabric module.
Status: current Access: read-only
OBJECT-IDENTITY    

e320Sfm100 1.3.6.1.4.1.4874.4.2.3.1.6.1
E320 100Gb switch fabric module. The SFM functions include buffer management, queuing, scheduling and packet processing.
Status: current Access: read-only
OBJECT-IDENTITY    

e320Sfm320 1.3.6.1.4.1.4874.4.2.3.1.6.2
E320 320Gb switch fabric module. The SFM functions include buffer management, queuing, scheduling and packet processing.
Status: current Access: read-only
OBJECT-IDENTITY    

e120Sfm120 1.3.6.1.4.1.4874.4.2.3.1.6.3
E120 120Gb switch fabric module. The SFM functions include buffer management, queuing, scheduling and packet processing.
Status: current Access: read-only
OBJECT-IDENTITY    

es2SrpIoa 1.3.6.1.4.1.4874.4.2.3.1.7
The vendor type ID for the system controller I/O adapter for a second generation E-series system.
Status: current Access: read-only
OBJECT-IDENTITY    

e320SrpIoa 1.3.6.1.4.1.4874.4.2.3.1.7.1
E320 SRP IOA. This card provides clocking functions as well as management and alarm interfaces.
Status: current Access: read-only
OBJECT-IDENTITY    

es2ForwardingModule 1.3.6.1.4.1.4874.4.2.3.1.8
The vendor type ID for a second generation E-series forwarding module.
Status: current Access: read-only
OBJECT-IDENTITY    

es2Lm4 1.3.6.1.4.1.4874.4.2.3.1.8.1
E320 4Gb (series 1) line module. This Line Module supports both uplink and customer facing IOAs and is responsible for processing data traffic.
Status: current Access: read-only
OBJECT-IDENTITY    


es2Lm10 1.3.6.1.4.1.4874.4.2.3.1.8.3
E320 10Gb (series 3) line module. This Line Module supports both uplink and customer facing IOAs and is responsible for processing data traffic.
Status: current Access: read-only
OBJECT-IDENTITY    

es2Lm10s 1.3.6.1.4.1.4874.4.2.3.1.8.4
E320 10Gb (series 4) line module. This Line Module supports both uplink and customer facing IOAs and is responsible for processing data traffic.
Status: current Access: read-only
OBJECT-IDENTITY    

es2ForwardingIoa 1.3.6.1.4.1.4874.4.2.3.1.9
The vendor type ID for a second generation E-series I/O adapter for a forwarding module.
Status: current Access: read-only
OBJECT-IDENTITY    

es2Ge4S1Ioa 1.3.6.1.4.1.4874.4.2.3.1.9.1
E320 GE-4 IOA. This is a series 1, half-height, single wide IOA with 4 physical interfaces that require pluggable GE interfaces. This IOA uses the full capacity of a Series 1 line module.
Status: current Access: read-only
OBJECT-IDENTITY    

es2Oc48Stm16PosS1Ioa 1.3.6.1.4.1.4874.4.2.3.1.9.2
E320 OC48/STM16 POS IOA. This is a series 1, half-height, single wide IOA with 1 physical interface that requires a pluggable OC48/STM16 interface.
Status: current Access: read-only
OBJECT-IDENTITY    

es2ServiceS1Ioa 1.3.6.1.4.1.4874.4.2.3.1.9.3
E320 service IOA. This is a series 1, full-height, single wide IOA and does not support any physical interfaces.
Status: current Access: read-only
OBJECT-IDENTITY    

es2Oc3Stm1x8AtmS1Ioa 1.3.6.1.4.1.4874.4.2.3.1.9.4
E320 OC3/STM1-8 ATM IOA. This is a series 1, half-height, single wide IOA that supports 8 physical interfaces that require pluggable OC3/STM1 interfaces. This IOA can be combined with other half-height IOAs (except those that use the full capacity of a slot's bandwidth such as the GE-4 IOA).
Status: current Access: read-only
OBJECT-IDENTITY    

es2RedundancyS1Ioa 1.3.6.1.4.1.4874.4.2.3.1.9.5
E320 redundancy IOA. This is a series 1, full-height, single wide IOA and does not support any physical interfaces.
Status: current Access: read-only
OBJECT-IDENTITY    

es2Oc12Stm4x2PosS1Ioa 1.3.6.1.4.1.4874.4.2.3.1.9.6
E320 OC12/STM4-2 POS IOA. This is a series 1, half-height, single wide IOA that supports 2 physical interfaces that require pluggable OC12/STM4 interfaces. This IOA can be combined with other half-height IOAs (except those that use the full capacity of a slot's bandwidth such as the GE-4 IOA).
Status: current Access: read-only
OBJECT-IDENTITY    

es2Oc12Stm4x2AtmS1Ioa 1.3.6.1.4.1.4874.4.2.3.1.9.7
E320 OC12/STM4-2 ATM IOA. This is a series 1, half-height, single wide IOA that supports 2 physical interfaces that require pluggable OC12/STM4 interfaces. This IOA can be combined with other half-height IOAs (except those that use the full capacity of a slot's bandwidth such as the GE-4 IOA).
Status: current Access: read-only
OBJECT-IDENTITY    

es2dash10GeS1Ioa 1.3.6.1.4.1.4874.4.2.3.1.9.8
E320 10GE IOA. This is a series 1, full-height, single wide IOA that supports 2 physical interface that requires a pluggable 10GE interface.
Status: current Access: read-only
OBJECT-IDENTITY    

es2Ge8S1Ioa 1.3.6.1.4.1.4874.4.2.3.1.9.9
E320 GE-8 IOA. This is a series 1, half-height, single wide IOA that supports 8 physical interfaces that require pluggable GE transceivers. This IOA will support a configuration of 8 active or 4 active + 4 standby interfaces.
Status: current Access: read-only
OBJECT-IDENTITY    

es2dash10GePrS2Ioa 1.3.6.1.4.1.4874.4.2.3.1.9.10
E320 10GE IOA with port redundancy (PR). This is a series 2, full-height, single wide IOA that supports 2 physical interfaces (1 active + 1 standby) that require pluggable 10GE transceivers.
Status: current Access: read-only
OBJECT-IDENTITY    

es2Ge20S2Ioa 1.3.6.1.4.1.4874.4.2.3.1.9.11
E320 GE-20 IOA. This is a series 2, full-height, single wide IOA that supports 20 physical interfaces that require pluggable GE transceivers. This IOA will support a configuration of 20 active or 10 active + 10 standby interfaces.
Status: current Access: read-only
OBJECT-IDENTITY