Juniper-SLEP-MIB
File:
Juniper-SLEP-MIB.mib (12151 bytes)
Imported modules
Imported symbols
Defined Types
JuniSlepIfEntry |
|
SEQUENCE |
|
|
|
|
juniSlepIfIndex |
InterfaceIndex |
|
|
juniSlepKeepAliveTimer |
INTEGER |
|
|
juniSlepIfLowerIfIndex |
InterfaceIndexOrZero |
|
|
juniSlepIfRowStatus |
RowStatus |
|
|
juniSlepDownWhenLooped |
JuniEnable |
|
JuniSlepIfStatisticsEntry |
|
SEQUENCE |
|
|
|
|
juniSlepIfStatsIndex |
InterfaceIndex |
|
|
juniSlepKeepAliveFailures |
Counter32 |
|
|
juniSlepLinkStatusTooLongPackets |
Counter32 |
|
|
juniSlepLinkStatusBadFCSs |
Counter32 |
|
Defined Values
juniSlepMIBS |
1.3.6.1.4.1.4874.2.2.15 |
The Serial Line Encapulation Protocol (SLEP) MIB for the Juniper
Networks enterprise. |
MODULE-IDENTITY |
|
|
|
juniSlepNextIfIndex |
1.3.6.1.4.1.4874.2.2.15.1.1.1 |
Coordinate ifIndex value allocation for entries in juniSlepIfTable.
A GET of this object returns the next available ifIndex value to be used
to create an entry in the associated interface table; or zero, if no
valid ifIndex value is available. This object also returns a value of
zero when it is the lexicographic successor of a varbind presented in an
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
that ifIndex allocation is unintended.
Successive GETs will typically return different values, thus avoiding
collisions among cooperating management clients seeking to create table
entries simultaneously. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
JuniNextIfIndex |
|
|
juniSlepIfTable |
1.3.6.1.4.1.4874.2.2.15.1.1.2 |
The parameters for the SLEP service on this interface. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
JuniSlepIfEntry |
|
juniSlepIfEntry |
1.3.6.1.4.1.4874.2.2.15.1.1.2.1 |
The Parameters for a particular SLEP interface.
Creating/deleting entries in this table causes corresponding entries for
be created/deleted in ifTable/ifXTable/juniIfTable. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
JuniSlepIfEntry |
|
|
juniSlepIfIndex |
1.3.6.1.4.1.4874.2.2.15.1.1.2.1.1 |
The ifIndex value of the corresponding ifEntry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
InterfaceIndex |
|
|
juniSlepKeepAliveTimer |
1.3.6.1.4.1.4874.2.2.15.1.1.2.1.2 |
The interface keep alive timer for this entry. The time in seconds
that this entity will wait for sending a keep-alive-message to the
remote SLEP entity, and the time in seconds that this entity will wait
for the reception of a keep-alive-message from the remote SLEP entity. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..6553 |
|
juniSlepIfLowerIfIndex |
1.3.6.1.4.1.4874.2.2.15.1.1.2.1.3 |
The ifIndex of an interface over which this SLEP interface is to be
layered. A value of zero indicates no layering. An implementation may
choose to require that a nonzero value be configured at entry creation. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
InterfaceIndexOrZero |
|
|
juniSlepIfRowStatus |
1.3.6.1.4.1.4874.2.2.15.1.1.2.1.4 |
Controls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniSlepIfRowStatus
juniSlepIfLowerIfIndex
In addition, when creating an entry the following conditions must hold:
A value for juniSlepIfIndex must have been determined previously, by
reading juniSlepNextIfIndex.
The interface identified by juniSlepIfLowerIfIndex must exist, and
must be an interface type that permits layering of SLEP Interface
above it.
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
destroyed as a result of creating/destroying an entry in this table. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
juniSlepDownWhenLooped |
1.3.6.1.4.1.4874.2.2.15.1.1.2.1.5 |
The down-when-looped control for this entry. This attribute determines
if loop detection is enabled for the interface. If set to disable, loop
detection is disabled for the interface. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
JuniEnable |
|
|
juniSlepIfStatisticsEntry |
1.3.6.1.4.1.4874.2.2.15.1.1.3.1 |
The statistics for a particular SLEP interface. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
JuniSlepIfStatisticsEntry |
|
|
juniSlepCompliance |
1.3.6.1.4.1.4874.2.2.15.4.1.1 |
Obsolete compliance statement for entities which implement the Juniper
SLEP MIB. This compliance statement became obsolete when the
juniSlepDownWhenLooped object was added. |
Status: obsolete |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
juniSlepCompliance2 |
1.3.6.1.4.1.4874.2.2.15.4.1.2 |
The compliance statement for entities which implement the Juniper
SLEP MIB. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
juniSlepGroup |
1.3.6.1.4.1.4874.2.2.15.4.2.1 |
Obsolete collection of objects providing management of SLEP interfaces
in a Juniper product. This group became obsolete when the
juniSlepDownWhenLooped object was added. |
Status: obsolete |
Access: read-only |
OBJECT-GROUP |
|
|
|
juniSlepGroup2 |
1.3.6.1.4.1.4874.2.2.15.4.2.2 |
A collection of objects providing management of SLEP interfaces in a
Juniper product. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|