Juniper-UNI-ATM-MIB

File: Juniper-UNI-ATM-MIB.mib (236592 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMP-FRAMEWORK-MIB
SNMPv2-CONF IF-MIB ATM-TC-MIB
ATM-MIB ATM-FORUM-SNMP-M4-MIB Juniper-MIBs
Juniper-TC

Imported symbols

MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE
NOTIFICATION-TYPE Integer32 Unsigned32
Counter64 Counter32 IpAddress
TimeTicks TEXTUAL-CONVENTION RowStatus
TruthValue TimeStamp DisplayString
SnmpAdminString MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP InterfaceIndex InterfaceIndexOrZero
ifIndex AtmVpIdentifier AtmVcIdentifier
AtmVorXAdminStatus AtmAddr atmVplVpi
atmVclVpi atmVclVci atmfM4VpTestObject
atmfM4VpTestId atmfM4VpTestType atmfM4VpTestResult
atmfM4VcTestObject atmfM4VcTestId atmfM4VcTestType
atmfM4VcTestResult atmfM4VpTestCode atmfM4VcTestCode
juniMibs JuniNextIfIndex JuniEnable
JuniInterfaceLocationType JuniInterfaceLocationValue

Defined Types

JuniAtmNbmaMapName  
An administratively assigned map name. Represents textual information taken from the NVT ASCII character set. The name must be unique per system.
TEXTUAL-CONVENTION    
  OCTET STRING Size(1..32)  

JuniAtmNbmaMapNameOrNull  
An administratively assigned map name. Represents textual information taken from the NVT ASCII character set. The name must be unique per system. Differs from JuniAtmNbmaMapName in that it permits a zero-length string.
TEXTUAL-CONVENTION    
  OCTET STRING Size(0..32)  

JuniAtmLocationType  
Obsolete description of the platform-dependent interpretation of a JuniAtmLocationValue object. This textual convention has been relpaced by Juniper-TC.JuniInterfaceLocationType.
TEXTUAL-CONVENTION    
  INTEGER unknown(0), slotPort(1)  

JuniAtmLocationValue  
Obsolete value of a platform-dependent interface location, represented as an OCTET STRING. A corresponding JuniAtmLocationType object identified the mapping of octets to location elements, e.g. 'slot.port'. This textual convention has been replaced by Juniper-TC.JuniInterfaceLocationValue.
TEXTUAL-CONVENTION    
  OCTET STRING Size(1..16)  

JuniAtmIfEntry  
SEQUENCE    
  juniAtmIfIndex InterfaceIndex
  juniAtmIfRowStatus RowStatus
  juniAtmIfLowerIfIndex InterfaceIndexOrZero
  juniAtmIfIlmiVpi AtmVpIdentifier
  juniAtmIfIlmiVci AtmVcIdentifier
  juniAtmIfIlmiVcd Integer32
  juniAtmIfIlmiPollFrequency Integer32
  juniAtmIfIlmiAdminState INTEGER
  juniAtmIfUniVersion INTEGER
  juniAtmIfOamCellRxAdminState INTEGER
  juniAtmIfInCells Counter64
  juniAtmIfOutCells Counter64
  juniAtmIfVcCount Integer32
  juniAtmIfMapGroup JuniAtmNbmaMapNameOrNull
  juniAtmIfCacAdminState JuniEnable
  juniAtmIfCacUbrWeight Integer32
  juniAtmIfCacSubscriptionBandwidth Integer32
  juniAtmIfCacAvailableBandwidth Integer32
  juniAtmIfCacAvailableBandwidthRx Integer32
  juniAtmIfE164Autoconversion INTEGER
  juniAtmIfE164Gateway INTEGER
  juniAtmIfE164OneToOneAddrTrans INTEGER
  juniAtmIfOamCellFilter INTEGER
  juniAtmIfCacUsedBandwidthUpper Unsigned32
  juniAtmIfCacUsedBandwidthLower Unsigned32
  juniAtmIfAssociatedVcClassId Unsigned32

JuniAtmPvcStatisticsEntry  
SEQUENCE    
  juniAtmPvcStatsIfIndex InterfaceIndex
  juniAtmPvcStatsVpi AtmVpIdentifier
  juniAtmPvcStatsVci AtmVcIdentifier
  juniAtmPvcStatsInCells Counter64
  juniAtmPvcStatsInCellOctets Counter64
  juniAtmPvcStatsInPackets Counter64
  juniAtmPvcStatsInPacketOctets Counter64
  juniAtmPvcStatsOutCells Counter64
  juniAtmPvcStatsOutCellOctets Counter64
  juniAtmPvcStatsOutPackets Counter64
  juniAtmPvcStatsOutPacketOctets Counter64
  juniAtmPvcStatsInCellErrors Counter32
  juniAtmPvcStatsinPacketErrors Counter32
  juniAtmPvcStatsOutCellErrors Counter32
  juniAtmPvcStatsOutPacketErrors Counter32
  juniAtmPvcStatsInPacketDiscards Counter32
  juniAtmPvcStatsInPacketOctetDiscards Counter32
  juniAtmPvcStatsInPacketUnknownProtocol Counter32

JuniAtmVpTunnelEntry  
SEQUENCE    
  juniAtmVpTunnelIfIndex InterfaceIndex
  juniAtmVpTunnelVpi AtmVpIdentifier
  juniAtmVpTunnelKbps Integer32
  juniAtmVpTunnelRowStatus RowStatus
  juniAtmVpTunnelServiceCategory INTEGER

JuniAtmIfCapabilityEntry  
SEQUENCE    
  juniAtmIfCapabilityIndex InterfaceIndex
  juniAtmIfCapabilityTrafficShaping TruthValue
  juniAtmIfCapabilityOam TruthValue
  juniAtmIfCapabilityDefaultVcPerVp Integer32
  juniAtmIfCapabilityNumVpiVciBits Integer32
  juniAtmIfCapabilityMaxVcd Integer32
  juniAtmIfCapabilityMaxVpi AtmVpIdentifier
  juniAtmIfCapabilityMaxVci AtmVcIdentifier
  juniAtmIfCapabilityOamCellFilter TruthValue

JuniAtmIfSvcSignallingEntry  
SEQUENCE    
  juniAtmIfSvcSignallingVpi AtmVpIdentifier
  juniAtmIfSvcSignallingVci AtmVcIdentifier
  juniAtmIfSvcSignallingVcd Integer32
  juniAtmIfSvcSignallingAdminStatus AtmVorXAdminStatus

JuniAtmIfPnniRccEntry  
SEQUENCE    
  juniAtmIfPnniRccVpi AtmVpIdentifier
  juniAtmIfPnniRccVci AtmVcIdentifier
  juniAtmIfPnniRccVcd Integer32
  juniAtmIfPnniRccAdminStatus AtmVorXAdminStatus

JuniAtmOamF4FlowEndToEndCfgEntry  
SEQUENCE    
  juniAtmOamF4FlowEndToEndIfIndex InterfaceIndex
  juniAtmOamF4FlowEndToEndVpi Integer32
  juniAtmOamF4FlowEndToEndLoopbackTimer Integer32
  juniAtmOamF4FlowEndToEndCCSink TruthValue
  juniAtmOamF4FlowEndToEndCCSource TruthValue
  juniAtmOamF4FlowEndToEndRowStatus RowStatus

JuniAtmOamF4FlowSegmentCfgEntry  
SEQUENCE    
  juniAtmOamF4FlowSegmentIfIndex InterfaceIndex
  juniAtmOamF4FlowSegmentVpi Integer32
  juniAtmOamF4FlowSegmentCCSink TruthValue
  juniAtmOamF4FlowSegmentCCSource TruthValue
  juniAtmOamF4FlowSegmentRowStatus RowStatus

JuniAtmVpDescrEntry  
SEQUENCE    
  juniAtmVpDescription SnmpAdminString

JuniAtmF4FlowOamEndToEndStatsEntry  
SEQUENCE    
  juniAtmF4FlowInOamEndAisCells Counter32
  juniAtmF4FlowInOamEndRdiCells Counter32
  juniAtmF4FlowInOamEndCCCells Counter32
  juniAtmF4FlowInOamEndCCActDeActCells Counter32
  juniAtmF4FlowInOamEndLoopbackCells Counter32
  juniAtmF4FlowOutEndRdiCells Counter32
  juniAtmF4FlowOutEndCCCells Counter32
  juniAtmF4FlowOutEndCCActDeActCells Counter32
  juniAtmF4FlowOutEndToEndLoopbackCells Counter32
  juniAtmF4FlowEndActualLoopbackFreq Integer32
  juniAtmF4FlowEndLastTimeChanged TimeTicks
  juniAtmF4FlowOamEndVpOperationState INTEGER
  juniAtmF4FlowOamEndVpAdminState INTEGER
  juniAtmF4FlowEndInOamCells Counter32
  juniAtmF4FlowEndOutOamCells Counter32
  juniAtmF4FlowEndInOamCellsDropped Counter32
  juniAtmF4FlowEndToEndInLoopbackCmds Counter32
  juniAtmF4FlowEndToEndInLoopbackRsps Counter32
  juniAtmF4FlowEndToEndOutLoopbackCmds Counter32
  juniAtmF4FlowEndToEndOutLoopbackRsps Counter32

JuniAtmF4FlowOamSegmentStatsEntry  
SEQUENCE    
  juniAtmF4FlowInOamSegmentAisCells Counter32
  juniAtmF4FlowInOamSegmentRdiCells Counter32
  juniAtmF4FlowInOamSegmentCCCells Counter32
  juniAtmF4FlowInOamSegmentCCActDeActCells Counter32
  juniAtmF4FlowInOamSegmentLoopbackCells Counter32
  juniAtmF4FlowOutSegmentRdiCells Counter32
  juniAtmF4FlowOutSegmentCCCells Counter32
  juniAtmF4FlowOutSegmentCCActDeActCells Counter32
  juniAtmF4FlowOutSegmentLoopbackCells Counter32
  juniAtmF4FlowSegmentLastTimeChanged TimeTicks
  juniAtmF4FlowOamSegmentVpOperationState INTEGER
  juniAtmF4FlowOamSegmentVpAdminState INTEGER
  juniAtmF4FlowSegmentInOamCells Counter32
  juniAtmF4FlowSegmentOutOamCells Counter32
  juniAtmF4FlowSegmentInOamCellsDropped Counter32
  juniAtmF4FlowSegmentInLoopbackCmds Counter32
  juniAtmF4FlowSegmentInLoopbackRsps Counter32
  juniAtmF4FlowSegmentOutLoopbackCmds Counter32
  juniAtmF4FlowSegmentOutLoopbackRsps Counter32

JuniAtmMartiniTimeoutTimerEntry  
SEQUENCE    
  juniAtmMartiniTimeoutTimerIndex INTEGER
  juniAtmMartiniTimeoutTimerValue Integer32

JuniAtmVpStatsEntry  
SEQUENCE    
  juniAtmVpStatsIfIndex InterfaceIndex
  juniAtmVpStatsVpi AtmVpIdentifier
  juniAtmVpStatsInCells Counter64
  juniAtmVpStatsInPackets Counter64
  juniAtmVpStatsInPacketOctets Counter64
  juniAtmVpStatsOutCells Counter64
  juniAtmVpStatsOutPackets Counter64
  juniAtmVpStatsOutPacketOctets Counter64
  juniAtmVpStatsInPacketErrors Counter32
  juniAtmVpStatsOutPacketErrors Counter32
  juniAtmVpStatsInPacketDiscards Counter32
  juniAtmVpStatsInPacketOctetDiscards Counter32
  juniAtmVpStatsInPacketUnknownProtocol Counter32
  juniAtmVpStatsCrcErrors Counter32
  juniAtmVpStatsSarTimeouts Counter32
  juniAtmVpStatsOverSizedPackets Counter32

JuniAtmAal5IfEntry  
SEQUENCE    
  juniAtmAal5IfIndex InterfaceIndex
  juniAtmAal5IfRowStatus RowStatus
  juniAtmAal5IfLowerIfIndex InterfaceIndexOrZero

JuniAtmBulkCircuitsNameEntry  
SEQUENCE    
  juniAtmBulkCircuitsNameAal5IfIndex InterfaceIndex
  juniAtmBulkCircuitsNameName DisplayString
  juniAtmBulkCircuitsNameRowStatus RowStatus
  juniAtmBulkCircuitsNameId Unsigned32

JuniAtmBulkCircuitsIdEntry  
SEQUENCE    
  juniAtmBulkCircuitsIdAal5IfIndex InterfaceIndex
  juniAtmBulkCircuitsIdId Unsigned32
  juniAtmBulkCircuitsIdName DisplayString
  juniAtmBulkCircuitsIdNextInstance Unsigned32

JuniAtmBulkCircuitsEntry  
SEQUENCE    
  juniAtmBulkCircuitsAal5IfIndex InterfaceIndex
  juniAtmBulkCircuitsId Unsigned32
  juniAtmBulkCircuitsInstance Unsigned32
  juniAtmBulkCircuitsRowStatus RowStatus
  juniAtmBulkCircuitsMinVpi AtmVpIdentifier
  juniAtmBulkCircuitsMaxVpi AtmVpIdentifier
  juniAtmBulkCircuitsMinVci AtmVcIdentifier
  juniAtmBulkCircuitsMaxVci AtmVcIdentifier
  juniAtmBulkCircuitsAdminState JuniEnable

JuniAtmProfileOverrideAssignIfCircuitEntry  
SEQUENCE    
  juniAtmProfileOverrideAssignIfCircuitAal5Index InterfaceIndex
  juniAtmProfileOverrideAssignIfCircuitRangeId Unsigned32
  juniAtmProfileOverrideAssignIfCircuitVpi AtmVpIdentifier
  juniAtmProfileOverrideAssignIfCircuitVci AtmVcIdentifier
  juniAtmProfileOverrideAssignIfCircuitRowStatus RowStatus
  juniAtmProfileOverrideAssignIfCircuitProfileId Unsigned32
  juniAtmProfileOverrideAssignIfCircuitOperStatus INTEGER

JuniAtmSubIfEntry  
SEQUENCE    
  juniAtmSubIfIndex InterfaceIndex
  juniAtmSubIfRowStatus RowStatus
  juniAtmSubIfDistinguisher Integer32
  juniAtmSubIfLowerIfIndex InterfaceIndexOrZero
  juniAtmSubIfNbma TruthValue
  juniAtmSubIfAddress AtmAddr
  juniAtmSubIfMtu Integer32
  juniAtmSubIfAdvisoryRxSpeed Integer32
  juniAtmSubIfMartiniMaxCellsPerPacket Integer32
  juniAtmSubIfMartiniTimeoutTimerId Integer32
  juniAtmSubIfAssociatedVcClassId Unsigned32

JuniAtmSubIfVccEntry  
SEQUENCE    
  juniAtmSubIfVccVpi AtmVpIdentifier
  juniAtmSubIfVccVci AtmVcIdentifier
  juniAtmSubIfVccRowStatus RowStatus
  juniAtmSubIfVccVcd Integer32
  juniAtmSubIfVccType INTEGER
  juniAtmSubIfVccServiceCategory INTEGER
  juniAtmSubIfVccPcr Integer32
  juniAtmSubIfVccScr Integer32
  juniAtmSubIfVccMbs Integer32
  juniAtmSubIfInverseArp TruthValue
  juniAtmSubIfInverseArpRefresh Integer32
  juniAtmSubIfVccAssociatedVcClassId Unsigned32

JuniAtmCircuitOamEntry  
SEQUENCE    
  juniAtmCircuitOamIfIndex InterfaceIndex
  juniAtmCircuitOamVpi AtmVpIdentifier
  juniAtmCircuitOamVci AtmVcIdentifier
  juniAtmCircuitOamAdminStatus INTEGER
  juniAtmCircuitOamLoopbackOperStatus INTEGER
  juniAtmCircuitVcOamOperStatus INTEGER
  juniAtmCircuitOamLoopbackFrequency Integer32
  juniAtmCircuitInOamF5Cells Counter32
  juniAtmCircuitInOamCellsDropped Counter32
  juniAtmCircuitOutOamF5Cells Counter32
  juniAtmCircuitInOamF5EndToEndLoopbackCells Counter32
  juniAtmCircuitInOamF5SegmentLoopbackCells Counter32
  juniAtmCircuitInOamF5AisCells Counter32
  juniAtmCircuitInOamF5RdiCells Counter32
  juniAtmCircuitOutOamF5EndToEndLoopbackCells Counter32
  juniAtmCircuitOutOamF5SegmentLoopbackCells Counter32
  juniAtmCircuitOutOamF5RdiCells Counter32
  juniAtmCircuitInOamF5EndToEndLoopbackCmds Counter32
  juniAtmCircuitInOamF5EndToEndLoopbackRsps Counter32
  juniAtmCircuitInOamF5SegmentLoopbackCmds Counter32
  juniAtmCircuitInOamF5SegmentLoopbackRsps Counter32
  juniAtmCircuitOutOamF5EndToEndLoopbackCmds Counter32
  juniAtmCircuitOutOamF5EndToEndLoopbackRsps Counter32
  juniAtmCircuitOutOamF5SegmentLoopbackCmds Counter32
  juniAtmCircuitOutOamF5SegmentLoopbackRsps Counter32
  juniAtmCircuitOamUpCount Integer32
  juniAtmCircuitOamDownCount Integer32
  juniAtmCircuitOamRetryFrequency Integer32
  juniAtmCircuitOamAlarmDownCount Integer32
  juniAtmCircuitOamAlarmClearTimeout Integer32

JuniAtmSubIfVccTrafficShapingEntry  
SEQUENCE    
  juniAtmSubIfVccTrafficShapingCdvt Unsigned32
  juniAtmSubIfVccTrafficShapingClp0 TruthValue
  juniAtmSubIfVccTrafficShapingTagging TruthValue
  juniAtmSubIfVccTrafficShapingPoliceObserve TruthValue
  juniAtmSubIfVccTrafficShapingPacketShaping TruthValue

JuniAtmSubIfSvcConfigEntry  
SEQUENCE    
  juniAtmSubIfSvcRowStatus RowStatus
  juniAtmSubIfSvcConfigDestAtmAddress AtmAddr
  juniAtmSubIfSvcConfigCircuitType INTEGER
  juniAtmSubIfSvcConfigServiceCategory INTEGER
  juniAtmSubIfSvcConfigPcr Unsigned32
  juniAtmSubIfSvcConfigScr Unsigned32
  juniAtmSubIfSvcConfigMbs Unsigned32
  juniAtmSubIfSvcConfigCdvt Unsigned32
  juniAtmSubIfSvcConfigClp0 TruthValue
  juniAtmSubIfSvcConfigTagging TruthValue
  juniAtmSubIfSvcConfigObserve TruthValue
  juniAtmSubIfSvcConfigPacketDiscard TruthValue
  juniAtmSubIfSvcConfigDestE164Address AtmAddr

JuniAtmNbmaMapEntry  
SEQUENCE    
  juniAtmNbmaMapName JuniAtmNbmaMapName
  juniAtmNbmaMapVcd Integer32
  juniAtmNbmaMapIpAddress IpAddress
  juniAtmNbmaMapVpi AtmVpIdentifier
  juniAtmNbmaMapVci AtmVcIdentifier
  juniAtmNbmaMapIfIndex InterfaceIndexOrZero
  juniAtmNbmaMapBroadcast TruthValue
  juniAtmNbmaMapRowStatus RowStatus

JuniAtmNbmaMapListEntry  
SEQUENCE    
  juniAtmNbmaMapListName JuniAtmNbmaMapName
  juniAtmNbmaMapListRowStatus RowStatus

JuniAtmVpPingEntry  
SEQUENCE    
  juniAtmVpPingProbeCount Unsigned32
  juniAtmVpPingTimeOut Unsigned32
  juniAtmVpPingCtlTrapGeneration BITS
  juniAtmVpPingSentProbes Unsigned32
  juniAtmVpPingProbeResponses Unsigned32
  juniAtmVpPingStartTime TimeStamp
  juniAtmVpPingMinRtt Unsigned32
  juniAtmVpPingMaxRtt Unsigned32
  juniAtmVpPingAverageRtt Unsigned32

JuniAtmVcPingEntry  
SEQUENCE    
  juniAtmVcPingProbeCount Unsigned32
  juniAtmVcPingTimeOut Unsigned32
  juniAtmVcPingCtlTrapGeneration BITS
  juniAtmVcPingSentProbes Unsigned32
  juniAtmVcPingProbeResponses Unsigned32
  juniAtmVcPingStartTime TimeStamp
  juniAtmVcPingMinRtt Unsigned32
  juniAtmVcPingMaxRtt Unsigned32
  juniAtmVcPingAverageRtt Unsigned32

JuniAtmSubIfLocationEntry  
SEQUENCE    
  juniAtmSubIfLocationIndex JuniInterfaceLocationValue
  juniAtmSubIfLocationIfIndex InterfaceIndex

JuniAtmVcClassNameEntry  
SEQUENCE    
  juniAtmVcClassName DisplayString
  juniAtmVcClassNameRowStatus RowStatus
  juniAtmVcClassNameId Unsigned32

JuniAtmVcClassIdEntry  
SEQUENCE    
  juniAtmVcClassIdId Unsigned32
  juniAtmVcClassIdName DisplayString

JuniAtmVcClassEntry  
SEQUENCE    
  juniAtmVcClassId Unsigned32
  juniAtmVcClassVccType INTEGER
  juniAtmVcClassVccServiceCategory INTEGER
  juniAtmVcClassVccPcr Integer32
  juniAtmVcClassVccScr Integer32
  juniAtmVcClassVccMbs Integer32
  juniAtmVcClassVccOamAdminStatus INTEGER
  juniAtmVcClassVccOamLoopbackFrequency Integer32
  juniAtmVcClassVccOamUpCount Integer32
  juniAtmVcClassVccOamDownCount Integer32
  juniAtmVcClassVccOamRetryFrequency Integer32
  juniAtmVcClassVccOamAlarmDownCount Integer32
  juniAtmVcClassVccOamAlarmClearTimeout Integer32
  juniAtmVcClassVccInverseArp TruthValue
  juniAtmVcClassVccInverseArpRefresh Integer32

Defined Values

juniAtmMIB 1.3.6.1.4.1.4874.2.2.8
The ATM MIB for the Juniper enterprise.
MODULE-IDENTITY    

juniAtmObjects 1.3.6.1.4.1.4874.2.2.8.1
OBJECT IDENTIFIER    

juniAtmIfLayer 1.3.6.1.4.1.4874.2.2.8.1.1
OBJECT IDENTIFIER    

juniAtmAal5IfLayer 1.3.6.1.4.1.4874.2.2.8.1.2
OBJECT IDENTIFIER    

juniAtmSubIfLayer 1.3.6.1.4.1.4874.2.2.8.1.3
OBJECT IDENTIFIER    

juniAtmNbma 1.3.6.1.4.1.4874.2.2.8.1.4
OBJECT IDENTIFIER    

juniAtmPing 1.3.6.1.4.1.4874.2.2.8.1.5
OBJECT IDENTIFIER    

juniAtmLocation 1.3.6.1.4.1.4874.2.2.8.1.6
OBJECT IDENTIFIER    

juniAtmVcClass 1.3.6.1.4.1.4874.2.2.8.1.7
OBJECT IDENTIFIER    

juniAtmNextIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.1
Coordinate ifIndex value allocation for entries in juniAtmIfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
Status: current Access: read-only
OBJECT-TYPE    
  JuniNextIfIndex  

juniAtmIfTable 1.3.6.1.4.1.4874.2.2.8.1.1.2
This table contains entries for ATM interfaces present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmIfEntry

juniAtmIfEntry 1.3.6.1.4.1.4874.2.2.8.1.1.2.1
Each entry describes the characteristics of an ATM interface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmIfEntry  

juniAtmIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.1
The ifIndex of the ATM interface. When creating entries in this table, suitable values for this object are determined by reading juniAtmNextIfIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmIfRowStatus 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.2
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmIfRowStatus juniAtmIfLowerIfIndex In addition, when creating an entry the following condition must hold: A value for juniAtmIfIndex must have been determined previously, by reading juniAtmNextIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created or destroyed as a result of creating/destroying an entry in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmIfLowerIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.3
The ifIndex of an interface over which this ATM interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniAtmIfIlmiVpi 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.4
The VPI of the ILMI of a major ATM interface.
Status: current Access: read-create
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmIfIlmiVci 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.5
The VCI of the ILMI of a major ATM interface.
Status: current Access: read-create
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmIfIlmiVcd 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.6
An integer identifier for the ILMI, used in conjunction with the command-line interface. The value must be unique among VCs configured on the same ATM interface.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfIlmiPollFrequency 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.7
The amount of time in seconds between successive transmissions of ILMI messages on this interface for the purpose of detecting loss of ILMI connectivity. The distinguished value zero disables ILMI connectivity procedures on this interface.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..65535  

juniAtmIfIlmiAdminState 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.8
The administrative status of ILMI in the ATM interface.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

juniAtmIfUniVersion 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.9
Use to specify the User Network Interface (UNI) the router should use when ILMI link auto determination is unsuccesful or ILMI is disabled.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER uniVersionAutoConfig(0), version3Dot0(1), version3Dot1(2), version4Dot0(3)  

juniAtmIfOamCellRxAdminState 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.10
Use to specify the OAM Cell Receive Administrative state on this interface.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER oamCellAdminStateDisabled(0), oamCellAdminStateEnabled(1)  

juniAtmIfInCells 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.11
The total number of cells received on this major interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmIfOutCells 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.12
The total number of cells transmitted on this major interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmIfVcCount 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.13
The total number of circuits configured on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..268431360  

juniAtmIfMapGroup 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.14
The NBMA map group this interface is associated with.
Status: current Access: read-create
OBJECT-TYPE    
  JuniAtmNbmaMapNameOrNull  

juniAtmIfCacAdminState 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.15
The administrative staus of CAC on this ATM major interface.
Status: current Access: read-create
OBJECT-TYPE    
  JuniEnable  

juniAtmIfCacUbrWeight 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.16
The bandwidth associated with every UBR and UBR with PCR connection configured on the ATM major interface. This value is used for CAC computation. The units are kilo-bits per second (kbps).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfCacSubscriptionBandwidth 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.17
The subscribed bandwidth of the ATM major interface. If this value is not specified or set to 0, the effective port bandwidth is used. When a Get operation is performed the current effective bandwidth is returned. The units are kilo-bits per second (kbps).
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfCacAvailableBandwidth 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.18
The available bandwidth in Tx direction of the ATM major interface. As connections are added or deleted on the interface, this value is updated. The units are kilo-bits per second (kbps).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfCacAvailableBandwidthRx 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.19
The available bandwidth in Rx direction of the ATM major interface. As connections are added or deleted on the interface, this value is updated. The units are kilo-bits per second (kbps).
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfE164Autoconversion 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.20
The status of E164 autoconversion feature in the ATM interface.
Status: obsolete Access: read-create
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

juniAtmIfE164Gateway 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.21
The status of E164 gateway feature in the ATM interface.
Status: obsolete Access: read-create
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

juniAtmIfE164OneToOneAddrTrans 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.22
The status of E164 one-to-one address translation feature in the ATM interface.
Status: obsolete Access: read-create
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

juniAtmIfOamCellFilter 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.23
The type of OAM cells to discard when juniAtmIfOamCellRxAdminState is set to oamCellAdminStateDisabled. The value oamCellFilterAlarm discards received OAM AIS and RDI cells. The value oamCellFilterAll discards all received OAM cells. Note that when juniAtmIfOamCellRxAdminState is set to oamCellAdminStateEnabled, this object has no effect.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER oamCellFilterAll(0), oamCellFilterAlarm(1)  

juniAtmIfCacUsedBandwidthUpper 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.24
The most significant 32 bits of the CAC used bandwidth on the ATM major interface. The least significant 32 bits of the CAC used bandwidth are specified by juniAtmIfCacUsedBandwidthLower.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmIfCacUsedBandwidthLower 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.25
The least significant 32 bits of the CAC used bandwidth on the ATM major interface. The most significant 32 bits of the CAC used bandwidth are specified by juniAtmIfCacUsedBandwidthUpper.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmIfAssociatedVcClassId 1.3.6.1.4.1.4874.2.2.8.1.1.2.1.26
The integer identifier of the ATM VC class associated with this ATM interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this interface.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

juniAtmPvcStatisticsTable 1.3.6.1.4.1.4874.2.2.8.1.1.3
This table contains statistics for PVC entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmPvcStatisticsEntry

juniAtmPvcStatisticsEntry 1.3.6.1.4.1.4874.2.2.8.1.1.3.1
Each entry provides statistics on an ATM PVC.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmPvcStatisticsEntry  

juniAtmPvcStatsIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.1
The ifIndex of the ATM interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmPvcStatsVpi 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.2
The VPI of the ATM VCC used by this ATM interface and PVC.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmPvcStatsVci 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.3
The VCI of the ATM VCC used by this ATM interface and PVC.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmPvcStatsInCells 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.4
Received cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsInCellOctets 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.5
Received cells octets.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsInPackets 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.6
Received AAL PDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsInPacketOctets 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.7
Received AAL PDU octets.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsOutCells 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.8
Transmitted cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsOutCellOctets 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.9
Transmitted cell octets.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsOutPackets 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.10
Transmitted AAL PDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsOutPacketOctets 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.11
Transmitted AAL PDU octets.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmPvcStatsInCellErrors 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.12
Received cells dropped due to errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmPvcStatsinPacketErrors 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.13
Received packets dropped due to errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmPvcStatsOutCellErrors 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.14
Cells not transmitted due to errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmPvcStatsOutPacketErrors 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.15
Packets not transmitted due to errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmPvcStatsInPacketDiscards 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.16
Received packets w/o errors discarded.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmPvcStatsInPacketOctetDiscards 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.17
Received bytes w/o errors discarded.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmPvcStatsInPacketUnknownProtocol 1.3.6.1.4.1.4874.2.2.8.1.1.3.1.18
Received packets that are discarded because the interface can not discern or is not configured to support this protocol.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmVpTunnelTable 1.3.6.1.4.1.4874.2.2.8.1.1.4
This table contains entries for ATM VP Tunnels present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVpTunnelEntry

juniAtmVpTunnelEntry 1.3.6.1.4.1.4874.2.2.8.1.1.4.1
Each entry describes the characteristics of an ATM VP Tunnel.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmVpTunnelEntry  

juniAtmVpTunnelIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.1
The ifIndex of the ATM interface. The value of this object is the same as the juniAtmIfIndex object in the juniAtmIfTable. Entries in this table cannot be created unless the underlying ATM interface entry is created first in the juniAtmIfTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmVpTunnelVpi 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.2
The VPI value for this VP tunnel entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmVpTunnelKbps 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.3
The tunnel rate in kilobits per second (kbps) for this entry.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmVpTunnelRowStatus 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.4
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmVpTunnelRowStatus juniAtmVpTunnelKbps In addition, when creating an entry the following condition must hold: A correponding juniAtmVpTunnelIfIndex value must have been created in the juniAtmIfTable previously.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmVpTunnelServiceCategory 1.3.6.1.4.1.4874.2.2.8.1.1.4.1.5
The ATM service category for the tunnel.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER nrtVbr(1), cbr(2)  

juniAtmIfCapabilityTable 1.3.6.1.4.1.4874.2.2.8.1.1.5
This table contains entries for ATM interfaces present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmIfCapabilityEntry

juniAtmIfCapabilityEntry 1.3.6.1.4.1.4874.2.2.8.1.1.5.1
Each entry describes the capabilities of an ATM interface. A management client can use this table to determine differences in the configurable level of support across entries in this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmIfCapabilityEntry  

juniAtmIfCapabilityIndex 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.1
The ifIndex of the ATM interface. The value of this object is the same as juniAtmIfIndex in the juniAtmIfTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmIfCapabilityTrafficShaping 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.2
Indicates whether traffic shaping is supported on this interface; true(1) indicates that it is, false(2) indicates that it is not.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

juniAtmIfCapabilityOam 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.3
Indicates whether OAM is supported on this interface; true(1) indicates that it is, false(2) indicates that it is not.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

juniAtmIfCapabilityDefaultVcPerVp 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.4
The default number of VCs per VP for this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65536  

juniAtmIfCapabilityNumVpiVciBits 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.5
The total range of bits used for constructing VPI/VCI identifiers for this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 8..28  

juniAtmIfCapabilityMaxVcd 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.6
The maximum configurable value for a VCD on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfCapabilityMaxVpi 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.7
The maximum configurable value for a VPI on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmIfCapabilityMaxVci 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.8
The maximum configurable value for a VCI on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmIfCapabilityOamCellFilter 1.3.6.1.4.1.4874.2.2.8.1.1.5.1.9
Indicates whether OAM cell filter is supported on this interface; true(1) indicates that it is, false(2) indicates that it is not.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

juniAtmIfSvcSignallingTable 1.3.6.1.4.1.4874.2.2.8.1.1.6
This table contains entries for extending the juniAtmIfTable for configuring signalling information for switched virtual connection (SVC).
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmIfSvcSignallingEntry

juniAtmIfSvcSignallingEntry 1.3.6.1.4.1.4874.2.2.8.1.1.6.1
Each entry provides configuration parameters for ATM signalling on the interface.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  JuniAtmIfSvcSignallingEntry  

juniAtmIfSvcSignallingVpi 1.3.6.1.4.1.4874.2.2.8.1.1.6.1.1
The VPI identifier of the ATM circuit used for signalling for this interface.
Status: deprecated Access: read-write
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmIfSvcSignallingVci 1.3.6.1.4.1.4874.2.2.8.1.1.6.1.2
The VCI identifier of the ATM circuit used for signalling for this interface.
Status: deprecated Access: read-write
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmIfSvcSignallingVcd 1.3.6.1.4.1.4874.2.2.8.1.1.6.1.3
An integer identifier for the ATM circuit used for signalling on this interface.
Status: deprecated Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfSvcSignallingAdminStatus 1.3.6.1.4.1.4874.2.2.8.1.1.6.1.4
The administrative status of signalling on the ATM interface.
Status: deprecated Access: read-write
OBJECT-TYPE    
  AtmVorXAdminStatus  

juniAtmIfPnniRccTable 1.3.6.1.4.1.4874.2.2.8.1.1.7
This table contains entries for extending the juniAtmIfTable for configuring PNNI RCC information.
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmIfPnniRccEntry

juniAtmIfPnniRccEntry 1.3.6.1.4.1.4874.2.2.8.1.1.7.1
Each entry provides configuration parameters for PNNI RCC on the interface.
Status: obsolete Access: not-accessible
OBJECT-TYPE    
  JuniAtmIfPnniRccEntry  

juniAtmIfPnniRccVpi 1.3.6.1.4.1.4874.2.2.8.1.1.7.1.1
The VPI identifier of the ATM circuit used for PNNI RCC on this interface.
Status: obsolete Access: read-write
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmIfPnniRccVci 1.3.6.1.4.1.4874.2.2.8.1.1.7.1.2
The VCI identifier of the ATM circuit used for PNNI RCC on this interface.
Status: obsolete Access: read-write
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmIfPnniRccVcd 1.3.6.1.4.1.4874.2.2.8.1.1.7.1.3
An integer identifier for the ATM circuit used for PNNI RCC on this interface.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmIfPnniRccAdminStatus 1.3.6.1.4.1.4874.2.2.8.1.1.7.1.4
The administrative status of PNNI on the ATM interface.
Status: obsolete Access: read-write
OBJECT-TYPE    
  AtmVorXAdminStatus  

juniAtmOamF4FlowEndToEndCfgTable 1.3.6.1.4.1.4874.2.2.8.1.1.8
This table contains entries for F4 OAM end-to-end flows configured.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmOamF4FlowEndToEndCfgEntry

juniAtmOamF4FlowEndToEndCfgEntry 1.3.6.1.4.1.4874.2.2.8.1.1.8.1
Each entry provides configuration parameters for one F4 OAM end-to-end flow configured for each VPI.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmOamF4FlowEndToEndCfgEntry  

juniAtmOamF4FlowEndToEndIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.1
The ifIndex of the ATM interface to configure the F4 OAM end-to-end flow.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmOamF4FlowEndToEndVpi 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.2
Select the VPI for F4 OAM end-to-end flow configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..255  

juniAtmOamF4FlowEndToEndLoopbackTimer 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.3
Configure the timer for sending the F4 flow end-to-end loopback OAM cells. Setting this value will enable sending the F4 end cells on the circuit. It is not allowed to set the value to -1 and whenever it is read as -1 that means sending end loopback is not enabled. Setting the loopback timer, other than -1, will enable sending the end cells.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..600  

juniAtmOamF4FlowEndToEndCCSink 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.4
Enable/Disable F4 flow end-to-end continuity check sink end point for this VP.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmOamF4FlowEndToEndCCSource 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.5
Enable/Disable F4 flow end-to-end continuity check source end point for this VP.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmOamF4FlowEndToEndRowStatus 1.3.6.1.4.1.4874.2.2.8.1.1.8.1.6
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create/delete an entry in this table, the following entry objects MUST be explicitly configured: juniAtmOamF4FlowEndToEndRowStatus F4 OAM end loopback and CC tests are mutually exclusive, enabling one will disable the other automatically. So, it is not allowed either at the circuit creation time or after the circuit creation to issue a request to enable end-to-end loopback and CC tests simultaneouly. Enabling/disabling CC sink and source is one time operation. To re-enable either CC source and sink in way different to earlier, both has to be disabled from the previous.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmOamF4FlowSegmentCfgTable 1.3.6.1.4.1.4874.2.2.8.1.1.9
This table contains entries for F4 OAM Segment flows configured.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmOamF4FlowSegmentCfgEntry

juniAtmOamF4FlowSegmentCfgEntry 1.3.6.1.4.1.4874.2.2.8.1.1.9.1
Each entry provides configuration parameters for one F4 OAM Segment flow configured for each VPI.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmOamF4FlowSegmentCfgEntry  

juniAtmOamF4FlowSegmentIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.1
The ifIndex of the ATM interface to configure the F4 OAM segment flow.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmOamF4FlowSegmentVpi 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.2
Select the VPI for F4 OAM segment flow configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..255  

juniAtmOamF4FlowSegmentCCSink 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.3
Enable/Disable F4 flow segment continuity check sink end point for this VP.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmOamF4FlowSegmentCCSource 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.4
Enable/Disable F4 flow segment continuity check source end point for this VP.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmOamF4FlowSegmentRowStatus 1.3.6.1.4.1.4874.2.2.8.1.1.9.1.5
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create/delete an entry in this table, the following entry objects MUST be explicitly configured: juniAtmOamF4FlowSegmentRowStatus Enabling/disabling CC sink and source is one time operation. To re-enable either CC source and sink in way different to earlier, both has to be disabled from the previous. F4 OAM segment loopback test is not supported.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmVpDescrTable 1.3.6.1.4.1.4874.2.2.8.1.1.10
This table contains entries for ATM VP Description present in the system. The user can configure a description of up to 32 characters for every VP in the ATM interface. A row exists for every VP on the ATM interface. These rows get created as soon as the ATM major interface created.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVpDescrEntry

juniAtmVpDescrEntry 1.3.6.1.4.1.4874.2.2.8.1.1.10.1
Each entry contains the description of the VP.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmVpDescrEntry  

juniAtmVpDescription 1.3.6.1.4.1.4874.2.2.8.1.1.10.1.1
The description for this VP. The default value of this object is null string.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..32)  

juniAtmF4FlowOamEndToEndStatsTable 1.3.6.1.4.1.4874.2.2.8.1.1.11
This table contains entries for F4 flow EndToEnd OAM circuits stats.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmF4FlowOamEndToEndStatsEntry

juniAtmF4FlowOamEndToEndStatsEntry 1.3.6.1.4.1.4874.2.2.8.1.1.11.1
Each entry provides stats for one F4 OAM circuit for each VPI.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmF4FlowOamEndToEndStatsEntry  

juniAtmF4FlowInOamEndAisCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.1
Received end-to-end OAM F4 AIS cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamEndRdiCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.2
Received end-to-end OAM F4 RDI cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamEndCCCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.3
Received end-to-end OAM F4 CC cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamEndCCActDeActCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.4
Received end-to-end OAM F4 activation/de-activation cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamEndLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.5
Total received OAM F4 end-to-end loopback cells. Aggregate of juniAtmF4FlowEndToEndInLoopbackCmds and juniAtmF4FlowEndToEndInLoopbackRsps
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutEndRdiCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.6
Transmitted end-to-end OAM F4 RDI cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutEndCCCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.7
Transmitted end-to-end OAM F4 CC cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutEndCCActDeActCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.8
Transmitted end-to-end OAM F4 activation/de-activation cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutEndToEndLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.9
Total transmitted OAM F4 end-to-end loopback cells. Aggregate of juniAtmF4FlowEndToEndOutLoopbackCmds and juniAtmF4FlowEndToEndOutLoopbackRsps
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndActualLoopbackFreq 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.10
Actual end-to-end loopback Frequecy calculated for OAM cells transmission.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

juniAtmF4FlowEndLastTimeChanged 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.11
Last time end-to-end F4 OAM flow got changed.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

juniAtmF4FlowOamEndVpOperationState 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.12
Represents the F4 end-to-end OAM flow VP operation states. It can take one of the following operational state values: vcAisState - AIS cell received or underlying physical layer reporting transmission path AIS. vcRdiState - RDI cell received. vcDownRetry - OAM loopback failed, using retry frequency to verify that the VC is really down. vcUpRetry - OAM loopback successful, using retry frequency to verify that the VC is really up. vcUp - OAM loopback successful after up retry verification. vcDown - OAM loopback failed after down retry verification. vcNotManaged - No verification via loopback cells being performed. vpAisState - State when F4 AIS cell is received. vpRdiState - State when F4 RDI cell is received. vcInVpRdiState - The data vc is down as a result of VP failure thorugh F4 Rdi oam cell. vcInVpAisState - The data vc is down as a result of VP failure through F4 Ais oam cell. vcSegmentAisState - Segment AIS cell received. vcSegRdiState - Segment RDI cell received.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER vcAisState(0), vcRdiState(1), vcDownRetry(2), vcUpRetry(3), vcUp(4), vcDown(5), vcNotManaged(6), vpAisState(7), vpRdiState(8), vcInVpRdiState(9), vcInVpAisState(10), vcSegmentAisState(11), vcSegRdiState(12)  

juniAtmF4FlowOamEndVpAdminState 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.13
End-to-end VP admin state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER down(0), up(1)  

juniAtmF4FlowEndInOamCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.14
Received end-to-end OAM F4 loopback cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndOutOamCells 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.15
Transmitted end-to-end OAM F4 loopback cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndInOamCellsDropped 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.16
Received end-to-end OAM cells that were dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndToEndInLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.17
Received OAM F4 end-to-end loopback commands.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndToEndInLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.18
Received OAM F4 end-to-end loopback responses.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndToEndOutLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.19
Transmitted OAM F4 end-to-end loopback commands.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowEndToEndOutLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.1.11.1.20
Transmitted OAM F4 end-to-end loopback responses.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOamSegmentStatsTable 1.3.6.1.4.1.4874.2.2.8.1.1.12
This table contains entries for F4 flow Segment OAM circuits stats.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmF4FlowOamSegmentStatsEntry

juniAtmF4FlowOamSegmentStatsEntry 1.3.6.1.4.1.4874.2.2.8.1.1.12.1
Each entry provides stats for one F4 OAM circuit for each VPI.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmF4FlowOamSegmentStatsEntry  

juniAtmF4FlowInOamSegmentAisCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.1
Received end-to-end OAM F4 AIS cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamSegmentRdiCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.2
Received end-to-end OAM F4 RDI cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamSegmentCCCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.3
Received end-to-end OAM F4 CC cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamSegmentCCActDeActCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.4
Received end-to-end OAM F4 activation/de-activation cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowInOamSegmentLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.5
Total received OAM F4 segment loopback cells. Aggregate of juniAtmF4FlowSegmentInLoopbackCmds and juniAtmF4FlowSegmentInLoopbackRsps
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutSegmentRdiCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.6
Transmitted end-to-end OAM F4 RDI cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutSegmentCCCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.7
Transmitted end-to-end OAM F4 CC cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutSegmentCCActDeActCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.8
Transmitted end-to-end OAM F4 activation/de-activation cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowOutSegmentLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.9
Total transmitted OAM F4 segment loopback cells. Aggregate of juniAtmF4FlowSegmentOutLoopbackCmds and juniAtmF4FlowSegmentOutLoopbackRsps
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentLastTimeChanged 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.10
Last time end-to-end F4 OAM flow got changed.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

juniAtmF4FlowOamSegmentVpOperationState 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.11
Represents the F4 end-to-end OAM flow VP operation states. It can take one of the following operational state values: vcAisState - AIS cell received or underlying physical layer reporting transmission path AIS. vcRdiState - RDI cell received. vcDownRetry - OAM loopback failed, using retry frequency to verify that the VC is really down. vcUpRetry - OAM loopback successful, using retry frequency to verify that the VC is really up. vcUp - OAM loopback successful after up retry verification. vcDown - OAM loopback failed after down retry verification. vcNotManaged - No verification via loopback cells being performed. vpAisState - State when F4 AIS cell is received. vpRdiState - State when F4 RDI cell is received. vcInVpRdiState - The data vc is down as a result of VP failure thorugh F4 Rdi oam cell. vcInVpAisState - The data vc is down as a result of VP failure through F4 Ais oam cell. vcSegmentAisState - Segment AIS cell received. vcSegRdiState - Segment RDI cell received.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER vcAisState(0), vcRdiState(1), vcDownRetry(2), vcUpRetry(3), vcUp(4), vcDown(5), vcNotManaged(6), vpAisState(7), vpRdiState(8), vcInVpRdiState(9), vcInVpAisState(10), vcSegmentAisState(11), vcSegRdiState(12)  

juniAtmF4FlowOamSegmentVpAdminState 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.12
Segment VP admin state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER down(0), up(1)  

juniAtmF4FlowSegmentInOamCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.13
Received end-to-end OAM F4 loopback cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentOutOamCells 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.14
Transmitted end-to-end OAM F4 loopback cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentInOamCellsDropped 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.15
Received end-to-end OAM cells that were dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentInLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.16
Received OAM F4 segment loopback commands.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentInLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.17
Received OAM F4 segment loopback responses.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentOutLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.18
Transmitted OAM F4 segment loopback commands.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmF4FlowSegmentOutLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.1.12.1.19
Transmitted OAM F4 segment loopback responses.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmMartiniTimeoutTimerTable 1.3.6.1.4.1.4874.2.2.8.1.1.13
This table contains entries for ATM Martini cell aggregation timeout detection. The user can configure timeout values for three timers. A row exists for every separate timer supported. These rows get created as soon as the ERX system comes up.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmMartiniTimeoutTimerEntry

juniAtmMartiniTimeoutTimerEntry 1.3.6.1.4.1.4874.2.2.8.1.1.13.1
Each entry contains the timeout value of ATM Martini cell aggregation timer.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmMartiniTimeoutTimerEntry  

juniAtmMartiniTimeoutTimerIndex 1.3.6.1.4.1.4874.2.2.8.1.1.13.1.1
The ATM Martini cell aggregation timeout timer identifier.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER timer1(1), timer2(2), timer3(3)  

juniAtmMartiniTimeoutTimerValue 1.3.6.1.4.1.4874.2.2.8.1.1.13.1.2
The ATM Martini cell aggregation timeout timer value in microseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 100..4095  

juniAtmVpStatsTable 1.3.6.1.4.1.4874.2.2.8.1.1.14
This table contains entries for ATM VP statistics present in the system. A row exists for every VP on the ATM interface. These rows get created as soon as the ATM major interface created.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVpStatsEntry

juniAtmVpStatsEntry 1.3.6.1.4.1.4874.2.2.8.1.1.14.1
Each entry contain the VP statistics.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmVpStatsEntry  

juniAtmVpStatsIfIndex 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.1
The ifIndex of the ATM interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmVpStatsVpi 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.2
The VPI value of the virtual path for which statistics are retrieved.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmVpStatsInCells 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.3
Received cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmVpStatsInPackets 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.4
Received AAL5 PDUs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmVpStatsInPacketOctets 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.5
Received AAL5 PDU octets.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmVpStatsOutCells 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.6
Transmitted cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmVpStatsOutPackets 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.7
Transmitted AAL5 PDUs
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmVpStatsOutPacketOctets 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.8
Transmitted AAL5 PDU octets.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

juniAtmVpStatsInPacketErrors 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.9
Received packets dropped due to errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsOutPacketErrors 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.10
Packets not transmitted due to errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsInPacketDiscards 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.11
Received packets without errors discarded.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsInPacketOctetDiscards 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.12
Received bytes without errors discarded.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsInPacketUnknownProtocol 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.13
Received packets that are discarded because the interface can not discern or is not configured to support this protocol.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsCrcErrors 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.14
Received packets that are discarded because of check sum erros
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsSarTimeouts 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.15
Received packets that are discarded because of SAR timeout
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmVpStatsOverSizedPackets 1.3.6.1.4.1.4874.2.2.8.1.1.14.1.16
Over sized packets that are received on this VP.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmAal5NextIfIndex 1.3.6.1.4.1.4874.2.2.8.1.2.1
Coordinate ifIndex value allocation for entries in juniAtmAal5IfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
Status: current Access: read-only
OBJECT-TYPE    
  JuniNextIfIndex  

juniAtmAal5IfTable 1.3.6.1.4.1.4874.2.2.8.1.2.2
This table contains entries for ATM AAL5 interfaces present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmAal5IfEntry

juniAtmAal5IfEntry 1.3.6.1.4.1.4874.2.2.8.1.2.2.1
Each entry describes the characteristics of an ATM AAL5 interface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmAal5IfEntry  

juniAtmAal5IfIndex 1.3.6.1.4.1.4874.2.2.8.1.2.2.1.1
The ifIndex of the ATM AAL5 interface. When creating entries in this table, suitable values for this object are determined by reading juniAtmAal5NextIfIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmAal5IfRowStatus 1.3.6.1.4.1.4874.2.2.8.1.2.2.1.2
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmAal5IfRowStatus juniAtmAal5IfLowerIfIndex In addition, when creating an entry the following condition must hold: A value for juniAtmAal5IfIndex must have been determined previously, by reading juniAtmAal5NextIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created or destroyed as a result of creating/destroying an entry in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmAal5IfLowerIfIndex 1.3.6.1.4.1.4874.2.2.8.1.2.2.1.3
The ifIndex of an ATM interface over which this ATM AAL5 interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniAtmBulkCircuitsNameTable 1.3.6.1.4.1.4874.2.2.8.1.2.3
The entries in this table provide mappings of ATM bulk virtual circuit range names to local integer identifiers for those profiles. These integers are used as indexes into other MIB tables containing profile configuration parameters associated with the same profile name.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmBulkCircuitsNameEntry

juniAtmBulkCircuitsNameEntry 1.3.6.1.4.1.4874.2.2.8.1.2.3.1
A mapping of a ATM bulk virtual circuit range name to an integer identifier for that name.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmBulkCircuitsNameEntry  

juniAtmBulkCircuitsNameAal5IfIndex 1.3.6.1.4.1.4874.2.2.8.1.2.3.1.1
The ifIndex of the ATM AAL5 interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmBulkCircuitsNameName 1.3.6.1.4.1.4874.2.2.8.1.2.3.1.2
The ATM bulk virtual circuit range name uniquely identifying this entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(1..80)  

juniAtmBulkCircuitsNameRowStatus 1.3.6.1.4.1.4874.2.2.8.1.2.3.1.3
Controls creation/deletion of entries in this table. Only the values 'createAndGo' and 'destroy' may be SET. Creating an entry in this table creates corresponding entry in juniAtmBulkCircuitsIdTable. Deleting an entry in this table deletes corresponding entries in juniAtmBulkCircuitsIdTable, juniAtmBulkCircuitsTable and juniAtmProfileOverrideAssignIfCircuitTable.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmBulkCircuitsNameId 1.3.6.1.4.1.4874.2.2.8.1.2.3.1.4
The integer identifier associated with this ATM bulk virtual circuit range name. This value of this identifier is assigned by the device when an entry in this table is created.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmBulkCircuitsIdTable 1.3.6.1.4.1.4874.2.2.8.1.2.4
Provides inverse mapping of ATM bulk virtual circuit IDs to ATM bulk virtual circuit names.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmBulkCircuitsIdEntry

juniAtmBulkCircuitsIdEntry 1.3.6.1.4.1.4874.2.2.8.1.2.4.1
A mapping of an integer identifier to a ATM bulk virtual circuit name.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmBulkCircuitsIdEntry  

juniAtmBulkCircuitsIdAal5IfIndex 1.3.6.1.4.1.4874.2.2.8.1.2.4.1.1
The ifIndex of the ATM AAL5 interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmBulkCircuitsIdId 1.3.6.1.4.1.4874.2.2.8.1.2.4.1.2
The integer identifier associated with this ATM bulk virtual circuit name.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

juniAtmBulkCircuitsIdName 1.3.6.1.4.1.4874.2.2.8.1.2.4.1.3
The ATM bulk virtual circuit name having the associated identifier.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..80)  

juniAtmBulkCircuitsIdNextInstance 1.3.6.1.4.1.4874.2.2.8.1.2.4.1.4
The next available instance value for juniAtmBulkCircuitsEntry.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmBulkCircuitsTable 1.3.6.1.4.1.4874.2.2.8.1.2.5
This table contains bulk virtual circuit range parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmBulkCircuitsEntry

juniAtmBulkCircuitsEntry 1.3.6.1.4.1.4874.2.2.8.1.2.5.1
Each entry describes the characteristics of VC range.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmBulkCircuitsEntry  

juniAtmBulkCircuitsAal5IfIndex 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.1
The ifIndex of the ATM AAL5 interface on which this bulk virtual circuit sub-range is created.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmBulkCircuitsId 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.2
The integer identifier associated with this ATM bulk virtual circuit name.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

juniAtmBulkCircuitsInstance 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.3
The unique identifier of the ATM bulk virtual circuit sub-range.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

juniAtmBulkCircuitsRowStatus 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.4
Controls creation/deletion of entries in this table. Only the values 'createAndGo' and 'destroy' may be SET. Since none of the VPI/VCI minimum and maximum values have default values, all these values must be specified before setting RowStatus to 'createAndGo'. The VPI/VCI minimum and maximum values can only be configured upon creation. Deleting an entry in this table deletes corresponding entries in juniAtmProfileOverrideAssignIfCircuitTable.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmBulkCircuitsMinVpi 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.5
The minimum value of VPI for this circuit sub-range. This value must be less than or equal to the value of juniAtmBulkCircuitsMaxVpi.
Status: current Access: read-create
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmBulkCircuitsMaxVpi 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.6
The maximum value of VPI for this cicuit sub-range. This value must be equal to or greater than the value of juniAtmBulkCircuitsMinVpi.
Status: current Access: read-create
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmBulkCircuitsMinVci 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.7
The minimum value of VCI for this circuit sub-range. This value must be less than or equal to the value of juniAtmBulkCircuitsMaxVci.
Status: current Access: read-create
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmBulkCircuitsMaxVci 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.8
The maximum value of VCI for this circuit sub-range. This value must be equal to or greater than the value of juniAtmBulkCircuitsMinVci.
Status: current Access: read-create
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmBulkCircuitsAdminState 1.3.6.1.4.1.4874.2.2.8.1.2.5.1.9
The administrative status of this circuit sub-range.
Status: current Access: read-create
OBJECT-TYPE    
  JuniEnable  

juniAtmProfileOverrideAssignIfCircuitTable 1.3.6.1.4.1.4874.2.2.8.1.2.6
Table providing overriding profile assignment to a circuit configured as part of bulk-configuration. Circuit is identified by interface index and vpi, vci. The entries in this table specify which profile to use when creating and configuring a dynamic interface above a circuit specified by vpi and vci. This entry is effective when the circuit specified by juniAtmProfileOverrideAssignIfCircuitAal5Index, juniAtmProfileOverrideAssignIfCircuitRangeId, juniAtmProfileOverrideAssignIfCircuitVpi, juniAtmProfileOverrideAssignIfCircuitVci is part of bulk-configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmProfileOverrideAssignIfCircuitEntry

juniAtmProfileOverrideAssignIfCircuitEntry 1.3.6.1.4.1.4874.2.2.8.1.2.6.1
An assignment of a profile to a circuit configured as part of bulk-configuration on an AAL5 interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmProfileOverrideAssignIfCircuitEntry  

juniAtmProfileOverrideAssignIfCircuitAal5Index 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.1
The ifIndex of the AAL5 interface to which the profile is assigned.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmProfileOverrideAssignIfCircuitRangeId 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.2
The integer identifier associated with the ATM bulk circuit configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

juniAtmProfileOverrideAssignIfCircuitVpi 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.3
The VPI value of the circuit to which the profile is assigned.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmProfileOverrideAssignIfCircuitVci 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.4
The VCI value of the circuit to which the profile is assigned.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmProfileOverrideAssignIfCircuitRowStatus 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.5
Controls creation/deletion of entries in this table. Only the values 'createAndGo' and 'destroy' may be SET. Since the VPI, VCI and profileId values do not have any default values, all these values must be specified before setting RowStatus to 'createAndGo'. The VPI, VCI and profileId values can only be configured upon creation. None of these values can be modified except by deleting the entry.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmProfileOverrideAssignIfCircuitProfileId 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.6
The ID of the profile assigned to the circuit configured as part of bulk-configuration. Circuit is identified by interface index and vpi, vci.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

juniAtmProfileOverrideAssignIfCircuitOperStatus 1.3.6.1.4.1.4874.2.2.8.1.2.6.1.7
The operational status of the profile override assignment identified by this entry. It returns inactive(0), if a static ATM circuit with identical VPI/VCI values is present on the same ATM interface. In this case, this profile override will not be used to configure upper dynamic interfaces. It returns active(1), if no static ATM circuit with identical VPI/VCI values is present on the same ATM interface. In this case, this profile override will be used to configure upper dynamic interfaces.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inactive(0), active(1)  

juniAtmSubIfNextIfIndex 1.3.6.1.4.1.4874.2.2.8.1.3.1
Coordinate ifIndex value allocation for entries in juniAtmSubIfTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
Status: current Access: read-only
OBJECT-TYPE    
  JuniNextIfIndex  

juniAtmSubIfTable 1.3.6.1.4.1.4874.2.2.8.1.3.2
This table contains entries for ATM Subinterfaces present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmSubIfEntry

juniAtmSubIfEntry 1.3.6.1.4.1.4874.2.2.8.1.3.2.1
Each entry describes the characteristics of an ATM Subinterface. Creating/deleting entries in this table causes corresponding entries for be created/deleted in ifTable/ifXTable/juniIfTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmSubIfEntry  

juniAtmSubIfIndex 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.1
The ifIndex of the ATM Subinterface. When creating entries in this table, suitable values for this object are determined by reading juniAtmSubNextIfIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmSubIfRowStatus 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.2
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmSubIfRowStatus juniAtmSubIfLowerIndex In addition, when creating an entry the following condition must hold: A value for juniAtmSubIfIndex must have been determined previously, by reading juniAtmSubIfNextIfIndex. A corresponding entry in ifTable/ifXTable/juniIfTable is created or destroyed as a result of creating/destroying an entry in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmSubIfDistinguisher 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.3
An integer identifier for the subinterface, used in conjunction with the command-line interface. It is provided here for cross-reference purposes only. The value must be unique among subinterfaces configured on the same underlying ATM adaptation layer. The upper bound for the value is further constrained to be identical with the maximum number of subinterfaces supported by the lower interface. If this object is not configured, a value will be allocated internally and can be queried after table entry creation has succeeded.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmSubIfLowerIfIndex 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.4
The ifIndex of an ATM AAL5 interface over which this ATM subinterface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniAtmSubIfNbma 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.5
The NBMA administrative setting. Setting this value of this object to true(1) will enable multipoint access on this interface. Setting the value to false(2), will enable point to point access on this interface.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfAddress 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.6
Specifies the local ATM NSAP address of the circuit. A GET operation returns a full 20-octet NSAP. A SET operation only requires 7 octets, since the prefix can be implied.
Status: deprecated Access: read-create
OBJECT-TYPE    
  AtmAddr Size(0|7|20)  

juniAtmSubIfMtu 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.7
The size of the largest packet which can be sent/received on the interface, specified in octets.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmSubIfAdvisoryRxSpeed 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.8
Advisory receive speed, in kilobits per second (kbps), of this subinterface. This object has no impact on forwarding performance but may be used as a hint for underlying circuit receive speed.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmSubIfMartiniMaxCellsPerPacket 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.9
The number of cells that can be aggregated in a single ATM Martini packet in cell-relay mode.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..190  

juniAtmSubIfMartiniTimeoutTimerId 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.10
The timer identifier used to abandon cell aggregation when no cells are supplied for transmission in ATM Martini cell-relay mode.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..3  

juniAtmSubIfAssociatedVcClassId 1.3.6.1.4.1.4874.2.2.8.1.3.2.1.11
The integer identifier of the ATM VC class associated with this ATM sub interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this interface.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

juniAtmSubIfVccTable 1.3.6.1.4.1.4874.2.2.8.1.3.3
This table contains entries for ATM VCCs configured on ATM subinterfaces present in the system. An implementation may constrain the number of VCCs permitted to be configured per ATM Subinterface; in particular, an implementation may restrict each ATM Subinterface to have a single VCC. Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmSubIfVccEntry

juniAtmSubIfVccEntry 1.3.6.1.4.1.4874.2.2.8.1.3.3.1
Each entry describes the characteristics of an ATM subinterface VCC.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmSubIfVccEntry  

juniAtmSubIfVccVpi 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.1
The VPI of the ATM VCC used by this subinterface.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmSubIfVccVci 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.2
The VCI of the ATM VCC used by this subinterface.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmSubIfVccRowStatus 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.3
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniAtmSubIfVccRowStatus In addition, when creating an entry the following conditions must hold: The ATM Subinterface identified by juniAtmSubIfIndex must exist. A positive value configured for juniAtmSubIfVccVcd must not already be assigned to an existing VCC. For each value of juniAtmSubIfVccServiceCategory, additional dependent objects in the entry require configuration as identified here: juniAtmSubIfVccServiceCategory Requires configuration of: ------------------------------------------------------------ ubr ubrPcr juniAtmSubIfVccPcr nrtVbr juniAtmSubIfVccPcr juniAtmSubIfVccScr juniAtmSubIfVccMbs cbr juniAtmSubIfVccPcr rtVbr juniAtmSubIfVccPcr juniAtmSubIfVccScr juniAtmSubIfVccMbs ------------------------------------------------------------ Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmSubIfVccVcd 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.4
An integer identifier for the circuit, used in conjunction with the command-line interface. It is provided here for cross-reference purposes only. The value must be unique among VCCs configured on the same underlying ATM interface. If this object is not configured, or is configured with a value of zero, a value will be allocated internally and can be queried after table entry creation has succeeded.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmSubIfVccType 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.5
Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM. The 'autoconfig' value will recognize both VcMux and LLC formats. The 'aal5' and 'aal0' values are used for encapsulation methods for transport of ATM frames and cells over IP and MPLS networks when no encapsulation method is specified.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER rfc1483VcMux(0), rfc1483Llc(1), autoconfig(2), aal5(3), aal0(4)  

juniAtmSubIfVccServiceCategory 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.6
Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-RealTime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)  

juniAtmSubIfVccPcr 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.7
Peak Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmSubIfVccServiceCategory is configured to have one of the following values: ubrPcr nrtVbr cbr rtVbr
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmSubIfVccScr 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.8
Sustained Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmSubIfVccServiceCategory is configured to have the following value: nrtVbr rtVbr
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmSubIfVccMbs 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.9
Maximum Burst Size, in cells, of this circuit. This parameter is only required when juniAtmSubIfVccServiceCategory is configured to have the following value: nrtVbr rtVbr
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..16777215  

juniAtmSubIfInverseArp 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.10
Enables the inverse ARP protocol on this VCC; true(1) enables the protocol, false(2) disables it.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfInverseArpRefresh 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.11
The refresh rate in minutes between inverse ARP protocol messages.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..60  

juniAtmSubIfVccAssociatedVcClassId 1.3.6.1.4.1.4874.2.2.8.1.3.3.1.12
The integer identifier of the ATM VC class associated with this ATM sub interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this VC.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

juniAtmCircuitOamTable 1.3.6.1.4.1.4874.2.2.8.1.3.4
This table contains circuit OAM data for a PVC.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmCircuitOamEntry

juniAtmCircuitOamEntry 1.3.6.1.4.1.4874.2.2.8.1.3.4.1
Each entry provides OAM data on an ATM PVC.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmCircuitOamEntry  

juniAtmCircuitOamIfIndex 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.1
The ifIndex of the ATM subinterface.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

juniAtmCircuitOamVpi 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.2
The VPI of the ATM VCC used by this ATM interface and PVC.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmCircuitOamVci 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.3
The VCI of the ATM VCC used by this ATM interface and PVC.
Status: current Access: not-accessible
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmCircuitOamAdminStatus 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.4
The administrative state of OAM for the interface identified by this entry.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER oamAdminStateDisabled(1), oamAdminStateEnabled(2)  

juniAtmCircuitOamLoopbackOperStatus 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.5
The operational status of OAM for the interface identified by this entry. oamOperStatusNotSupported(0) - OAM not supported on this interface oamOperStatusDisabled(1) - VC integrity disabled oamOperStatusSent(2) - Loopback sent, awaiting response oamOperStatusReceived(3) - Loopback response received, awaiting frequency oamOperStatusFailed(4) - Loopback response not received, or invalid response received
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER oamOperStatusNotSupported(0), oamOperStatusDisabled(1), oamOperStatusSent(2), oamOperStatusReceived(3), oamOperStatusFailed(4)  

juniAtmCircuitVcOamOperStatus 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.6
The OAM VC operational status of this entry. oamVcOperStateAisState(0) - AIS cell received or underlying physical layer reporting transmission path AIS oamVcOperStateRdiState(1) - RDI cell received oamVcOperStateDownRetry(2) - OAM loopback failed, using retry frequency to verify that the VC is really down oamVcOperStateUpRetry(3) - OAM loopback successful, using retry frequency to verify that the VC is really up oamVcOperStateUp(4) - OAM loopback successful after up retry verification oamVcOperStateDown(5) - OAM loopback failed after down retry verification oamVcOperStateNotManaged(6)- No verification via loopback cells being performed oamVcOperStateVpAis(7) - F4 AIS cell received oamVcOperStateVpRdi(8) - F4 RDI cell received oamVcOperStateVcInVpRdi(9) - F4 RDI cell received; path failure oamVcOperStateVcInVpAis(10)- F4 AIS cell received; path failure oamVcOperStateSegAis(11) - Segment AIS cell received oamVcOperStateSegRdi(12) - Segment RDI cell received oamVcOperStateGenAis(13) - Connection failure; generating AIS cells.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER oamVcOperStateAisState(0), oamVcOperStateRdiState(1), oamVcOperStateDownRetry(2), oamVcOperStateUpRetry(3), oamVcOperStateUp(4), oamVcOperStateDown(5), oamVcOperStateNotManaged(6), oamVcOperStateVpAis(7), oamVcOperStateVpRdi(8), oamVcOperStateVcInVpRdi(9), oamVcoperStateVcInVpAis(10), oamVcOperStateSegAis(11), oamVcOperStateSegRdi(12), oamVcOperStateGenAis(13)  

juniAtmCircuitOamLoopbackFrequency 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.7
The OAM loopback frequency in seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..600  

juniAtmCircuitInOamF5Cells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.8
Received OAM F5 cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamCellsDropped 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.9
Received OAM cells that were dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5Cells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.10
Transmitted OAM F5 cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5EndToEndLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.11
Total received OAM F5 end-to-end loopback cells. Aggregate of juniAtmCircuitInOamF5EndToEndLoopbackCmds and juniAtmCircuitInOamF5EndToEndLoopbackRsps
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5SegmentLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.12
Total received OAM F5 segment loopback cells. Aggregate of juniAtmCircuitInOamF5SegmentLoopbackCmds and juniAtmCircuitInOamF5SegmentLoopbackRsps
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5AisCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.13
Received OAM F5 AIS cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5RdiCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.14
Received OAM F5 RDI cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5EndToEndLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.15
Total transmitted OAM F5 end-to-end loopback cells. Aggregate of juniAtmCircuitOutOamF5EndToEndLoopbackCmds and juniAtmCircuitOutOamF5EndToEndLoopbackRsps
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5SegmentLoopbackCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.16
Total transmitted OAM F5 segment loopback cells. Aggregate of juniAtmCircuitOutOamF5SegmentLoopbackCmds and juniAtmCircuitOutOamF5SegmentLoopbackRsps
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5RdiCells 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.17
Transmitted OAM F5 RDI cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5EndToEndLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.18
Received OAM F5 end-to-end loopback commands.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5EndToEndLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.19
Received OAM F5 end-to-end loopback responses.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5SegmentLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.20
Received OAM F5 segment loopback commands.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitInOamF5SegmentLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.21
Received OAM F5 segment loopback responses.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5EndToEndLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.22
Transmitted OAM F5 end-to-end loopback commands.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5EndToEndLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.23
Transmitted OAM F5 end-to-end loopback responses.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5SegmentLoopbackCmds 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.24
Transmitted OAM F5 segment loopback commands.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOutOamF5SegmentLoopbackRsps 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.25
Transmitted OAM F5 segment loopback responses.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

juniAtmCircuitOamUpCount 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.26
Specifies the number of successive loopback cell responses to receive before a PVC is up for connectivity verification.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..60  

juniAtmCircuitOamDownCount 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.27
Specifies the number of successive loopback cell responses not received before declaring a PVC down for connectivity verification.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..60  

juniAtmCircuitOamRetryFrequency 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.28
Specifies the frequency (in seconds) to transmit loopback cells when verifying PVC state (up or down) for connectivity verification.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..600  

juniAtmCircuitOamAlarmDownCount 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.29
Specifies the number of successive alarm (AIS or RDI) cells to receive before declaring a PVC down.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..60  

juniAtmCircuitOamAlarmClearTimeout 1.3.6.1.4.1.4874.2.2.8.1.3.4.1.30
Specifies how long to wait (in seconds) before declaring a PVC up after it has stopped receiving alarm cells.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..60  

juniAtmSubIfVccTrafficShapingTable 1.3.6.1.4.1.4874.2.2.8.1.3.5
This table contains entries for traffic shaping of ATM VCCs configured on ATM subinterfaces present in the system. This table augments the juniAtmSubIfVccTable only for VCCs that support traffic shapping. Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmSubIfVccTrafficShapingEntry

juniAtmSubIfVccTrafficShapingEntry 1.3.6.1.4.1.4874.2.2.8.1.3.5.1
Each entry describes the traffic shping characteristics of an ATM subinterface VCC.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmSubIfVccTrafficShapingEntry  

juniAtmSubIfVccTrafficShapingCdvt 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.1
The network cell delay variation tolerance (CDVT) in tenths of a microsecond.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

juniAtmSubIfVccTrafficShapingClp0 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.2
Specifies whether or not only CLP0 cells are to be policed according to the traffic contract. CLP1 cells are forwarded on a best-effort basis CLP-significant model for (VBR.2, VBR.3 conformance). Applicable only for VBR circuits.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfVccTrafficShapingTagging 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.3
Specifies whether or not CLP0 cells should be tagged for SCR policing (VBR.3 conformance). Applicable only for VBR circuits.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfVccTrafficShapingPoliceObserve 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.4
Specifies whether of not no policing action is to be taken (note the double negative; if true(1) then no policing action will be taken; if false(2) then policing action will be taken). Regardless of the state of this object, all counters will be incremented.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfVccTrafficShapingPacketShaping 1.3.6.1.4.1.4874.2.2.8.1.3.5.1.5
Specifies whether of not to shape output traffic on a packet boundary.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfSvcConfigTable 1.3.6.1.4.1.4874.2.2.8.1.3.6
This table contains entries for extending the juniAtmSubIfTable to configure switched virtual connection (SVC) on the subinterfaces.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmSubIfSvcConfigEntry

juniAtmSubIfSvcConfigEntry 1.3.6.1.4.1.4874.2.2.8.1.3.6.1
Each entry provides configuration parameters for an ATM SVC on the subinterface.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  JuniAtmSubIfSvcConfigEntry  

juniAtmSubIfSvcRowStatus 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.1
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy
Status: deprecated Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmSubIfSvcConfigDestAtmAddress 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.2
Specifies the destination ATM NSAP address of the circuit.
Status: deprecated Access: read-create
OBJECT-TYPE    
  AtmAddr Size(20)  

juniAtmSubIfSvcConfigCircuitType 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.3
Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM.
Status: deprecated Access: read-create
OBJECT-TYPE    
  INTEGER rfc1483VcMux(0), rfc1483Llc(1)  

juniAtmSubIfSvcConfigServiceCategory 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.4
Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-RealTime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate.
Status: deprecated Access: read-create
OBJECT-TYPE    
  INTEGER ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)  

juniAtmSubIfSvcConfigPcr 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.5
Peak Cell Rate, in kilo-bits per second (kbps), of this circuit.
Status: deprecated Access: read-create
OBJECT-TYPE    
  Unsigned32  

juniAtmSubIfSvcConfigScr 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.6
Sustained Cell Rate, in kilo-bits per second (kbps), of this circuit.
Status: deprecated Access: read-create
OBJECT-TYPE    
  Unsigned32  

juniAtmSubIfSvcConfigMbs 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.7
Maximum Burst Size, in cells, of this circuit.
Status: deprecated Access: read-create
OBJECT-TYPE    
  Unsigned32  

juniAtmSubIfSvcConfigCdvt 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.8
Specify the network Cell Delay Variation Tolerance.
Status: obsolete Access: read-create
OBJECT-TYPE    
  Unsigned32  

juniAtmSubIfSvcConfigClp0 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.9
Specify that only CLP0 cells are to be policed according to the traffic contract. CLP1 cells are forwarded on a best-effort basis CLP-significant model for (VBR.2, VBR.3 conformance).
Status: deprecated Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfSvcConfigTagging 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.10
Specify that CLP0 cells should be tagged for SCR policing (VBR.3 conformance).
Status: deprecated Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfSvcConfigObserve 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.11
Specify that no policing action is to be taken; only counters are incremented.
Status: obsolete Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfSvcConfigPacketDiscard 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.12
Enable early packet Discard for this circuit.
Status: deprecated Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmSubIfSvcConfigDestE164Address 1.3.6.1.4.1.4874.2.2.8.1.3.6.1.13
Specifies the destination ATM E164 address of the circuit.
Status: obsolete Access: read-create
OBJECT-TYPE    
  AtmAddr Size(0|8)  

juniAtmSubIfDescriptionExport 1.3.6.1.4.1.4874.2.2.8.1.3.7
Enabling of this object will program the subinterface description down to the applicable line card. Note, the subinterface description sent down to the line card is a truncated version (32 bytes) of the ifAlias.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

juniAtmNbmaMapTable 1.3.6.1.4.1.4874.2.2.8.1.4.1
This table contains entries for ATM NBMA maps.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmNbmaMapEntry

juniAtmNbmaMapEntry 1.3.6.1.4.1.4874.2.2.8.1.4.1.1
Each entry describes the characteristics of an ATM NBMA map.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmNbmaMapEntry  

juniAtmNbmaMapName 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.1
The NBMA map name.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmNbmaMapName  

juniAtmNbmaMapVcd 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.2
An integer identifier for the ATM circuit, used in conjunction with the command-line interface. The value must be unique among VCs configured on the same ATM interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmNbmaMapIpAddress 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.3
The IP address associated with this entry.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

juniAtmNbmaMapVpi 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.4
The VPI identifier of the ATM circuit.
Status: current Access: read-only
OBJECT-TYPE    
  AtmVpIdentifier  

juniAtmNbmaMapVci 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.5
The VCI identifier of the ATM circuit.
Status: current Access: read-only
OBJECT-TYPE    
  AtmVcIdentifier  

juniAtmNbmaMapIfIndex 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.6
The ifIndex of the ATM major interface associated with this entry. The value of this object will be zero when the map is not applied to an interface.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniAtmNbmaMapBroadcast 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.7
The broadcast enable/disable setting for this entry. The value true(1) enable broadcast support; disable(2) disabled broadcast support for this entry.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniAtmNbmaMapRowStatus 1.3.6.1.4.1.4874.2.2.8.1.4.1.1.8
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy Additional notes to aid the network manager: - NBMA maps are not supported on dynamic interface. - NBMA maps can only be applied to a single major ATM interface at a time. - NBMA maps cannot be deleted unless the map is removed from the ATM interface (juniAtmNbmaMapIfIndex = 0). - The values of juniAtmNbmaMapVpi, juniAtmNbmaMapVci and juniAtmNbmaMapIfIndex are zero until the map is applied to a major ATM interface. - To create an entry in this table, the following objects must be present in the set PDU: juniAtmNbmaMapIpAddress juniAtmNbmaMapBroadcast juniAtmNbmaMapRowStatus - Once created, only the following objects can be modified: juniAtmNbmaMapBroadcast
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmNbmaMapListTable 1.3.6.1.4.1.4874.2.2.8.1.4.2
This table contains entries for ATM NBMA map lists.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmNbmaMapListEntry

juniAtmNbmaMapListEntry 1.3.6.1.4.1.4874.2.2.8.1.4.2.1
Each entry describes the characteristics of an ATM NBMA map.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmNbmaMapListEntry  

juniAtmNbmaMapListName 1.3.6.1.4.1.4874.2.2.8.1.4.2.1.1
The NBMA Map List name.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmNbmaMapName  

juniAtmNbmaMapListRowStatus 1.3.6.1.4.1.4874.2.2.8.1.4.2.1.2
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmPingTestTypes 1.3.6.1.4.1.4874.2.2.8.1.5.1
OBJECT IDENTIFIER    

juniAtmPingTestOamSeg 1.3.6.1.4.1.4874.2.2.8.1.5.1.1
This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC, VCL, or VCC termination point, using segment OAM cells. The test type must have appended to it a code that uniquely identifies an intermediate point responsible for looping back each cell. If this is absent, the loopbacks are performed at the end of the segment or connection. E.g., the OID { juniAtmPingTestOamSeg 5 } identifies that the loopbacks should be performed at the intermediate point labeled 5.
Status: current Access: read-create
OBJECT-IDENTITY    

juniAtmPingTestOamE2E 1.3.6.1.4.1.4874.2.2.8.1.5.1.2
This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC, VCL, or VCC termination point, using end-to-end OAM cells.
Status: current Access: read-create
OBJECT-IDENTITY    

juniAtmVpPingTable 1.3.6.1.4.1.4874.2.2.8.1.5.2
This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB atmM4VpTestTable to do ping (multiple loopback) type testing.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVpPingEntry

juniAtmVpPingEntry 1.3.6.1.4.1.4874.2.2.8.1.5.2.1
Each entry describes the characteristics, status and results of the most recent ATM ping test.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmVpPingEntry  

juniAtmVpPingProbeCount 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.1
The number of ping probes (OAM cells) to be sent to complete the test.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..32  

juniAtmVpPingTimeOut 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.2
Specifies the time-out value, in seconds, for a remote ping operation.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..5  

juniAtmVpPingCtlTrapGeneration 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.3
The value of this object determines when and if to generate a notification for this entry: testCompletion(0) - Generate a juniPingTestCompleted notification. The value of this object defaults to zero, indicating that no notification has been selected.
Status: current Access: read-write
OBJECT-TYPE    
  BITS testCompletion(0)  

juniAtmVpPingSentProbes 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.4
The number of ping probes (OAM cells) that have been sent thus far for this test. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmVpPingProbeResponses 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.5
The number of ping responses that have been received thus far for this test. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmVpPingStartTime 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.6
The time (sysUpTime) when the test started.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

juniAtmVpPingMinRtt 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.7
The shortest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmVpPingMaxRtt 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.8
The longest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmVpPingAverageRtt 1.3.6.1.4.1.4874.2.2.8.1.5.2.1.9
The average round-trip-time (RTT) for all the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmVcPingTable 1.3.6.1.4.1.4874.2.2.8.1.5.3
This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB atmM4VcTestTable to do ping (multiple loopback) type testing.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVcPingEntry

juniAtmVcPingEntry 1.3.6.1.4.1.4874.2.2.8.1.5.3.1
Each entry describes the characteristics, status and results of the most recent ATM ping test.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmVcPingEntry  

juniAtmVcPingProbeCount 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.1
The number of ping probes (OAM cells) to be sent to complete the test.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..32  

juniAtmVcPingTimeOut 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.2
Specifies the time-out value, in seconds, for a remote ping operation.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..5  

juniAtmVcPingCtlTrapGeneration 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.3
The value of this object determines when and if to generate a notification for this entry: testCompletion(0) - Generate a juniPingTestCompleted notification. The value of this object defaults to zero, indicating that no notification has been selected.
Status: current Access: read-write
OBJECT-TYPE    
  BITS testCompletion(0)  

juniAtmVcPingSentProbes 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.4
The number of ping probes (OAM cells) that have been sent thus far for this test. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmVcPingProbeResponses 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.5
The number of ping responses that have been received thus far for this test. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmVcPingStartTime 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.6
The time (sysUpTime) when the test started.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

juniAtmVcPingMinRtt 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.7
The shortest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmVcPingMaxRtt 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.8
The longest round-trip-time (RTT) for the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmVcPingAverageRtt 1.3.6.1.4.1.4874.2.2.8.1.5.3.1.9
The average round-trip-time (RTT) for all the pings that have received responses. The value of this object MUST be set to zero when the atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A value of zero for this object implies that no ping responses have been received for the current test.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmPingTestCode 1.3.6.1.4.1.4874.2.2.8.1.5.4
OBJECT IDENTIFIER    

juniAtmPingTestCodeOamDisabled 1.3.6.1.4.1.4874.2.2.8.1.5.4.1
This test code indicates that the ATM ping operation cannot be initiated or is aborted because the juniAtmIfOamCellRxAdminState is set to disabled.
Status: current Access: read-only
OBJECT-IDENTITY    

juniAtmPingTestCodeCircuitDown 1.3.6.1.4.1.4874.2.2.8.1.5.4.2
This test code indicates that the ATM ping operation cannot be initiated or is aborted because the operational status of the ATM circuit is down.
Status: current Access: read-only
OBJECT-IDENTITY    

juniAtmPingTestCodeStopped 1.3.6.1.4.1.4874.2.2.8.1.5.4.3
This test code indicates that the ATM ping operation is administratively stopped by an External Management.
Status: current Access: read-only
OBJECT-IDENTITY    

juniAtmPingTestCodeOamVcOperState 1.3.6.1.4.1.4874.2.2.8.1.5.4.4
This test code indicates that the ATM ping operation cannot be initiated or is aborted because the circuit is down because of a OAM fault condition. This is possible if juniAtmCircuitVcOamOperStatus is one of the following: oamVcOperStateAisState(0) - AIS cell received or underlying physical layer reporting transmission path AIS. oamVcOperStateRdiState(1) - RDI cell received.
Status: current Access: read-only
OBJECT-IDENTITY    

juniAtmPingTestCodeMaxPingCountReached 1.3.6.1.4.1.4874.2.2.8.1.5.4.5
This test code indicates that the ping operation cannot be initiated as the maximum number of ping possible on this interfaces exceeds the allowable limit.
Status: current Access: read-only
OBJECT-IDENTITY    

juniAtmPingTestCodeInvalidParams 1.3.6.1.4.1.4874.2.2.8.1.5.4.6
This Test Code identities the Ping operation cannot be initiated as one or more of the Ping Parameters is Invalid.
Status: current Access: read-only
OBJECT-IDENTITY    

juniAtmSubIfLocationType 1.3.6.1.4.1.4874.2.2.8.1.6.1
Describes the interpretation of JuniInterfaceLocationValue object values into platform-dependent interface location components, e.g., 'slot.port' on an ERX.
Status: current Access: read-only
OBJECT-TYPE    
  JuniInterfaceLocationType  

juniAtmSubIfLocationTable 1.3.6.1.4.1.4874.2.2.8.1.6.2
The entries in this table report the ifIndex of ATM Subinterfaces by location.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmSubIfLocationEntry

juniAtmSubIfLocationEntry 1.3.6.1.4.1.4874.2.2.8.1.6.2.1
A specification of ATM subinterfaces by location.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmSubIfLocationEntry  

juniAtmSubIfLocationIndex 1.3.6.1.4.1.4874.2.2.8.1.6.2.1.1
The value of a platform interface location.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniInterfaceLocationValue  

juniAtmSubIfLocationIfIndex 1.3.6.1.4.1.4874.2.2.8.1.6.2.1.2
The ifIndex value of this subinterface.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

juniAtmVcClassNameTable 1.3.6.1.4.1.4874.2.2.8.1.7.1
The entries in this table provide mappings of ATM VC class names to local integer identifiers. These integers are used as indexes into other MIB tables containing ATM VC attributes associated with the same VC class name.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVcClassNameEntry

juniAtmVcClassNameEntry 1.3.6.1.4.1.4874.2.2.8.1.7.1.1
A mapping of ATM VC class name to an integer identifier for the ATM VC class.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmVcClassNameEntry  

juniAtmVcClassName 1.3.6.1.4.1.4874.2.2.8.1.7.1.1.1
The ATM VC class name uniquely identifying this entry.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

juniAtmVcClassNameRowStatus 1.3.6.1.4.1.4874.2.2.8.1.7.1.1.2
Controls creation/deletion of entries in this table. Only the values 'createAndGo' ,'destroy', 'active' and 'notInService' may be SET. The SNMP manager would set the row status to notInService before making any VC class attribute changes explained in juniAtmVcClassTable. Once the VC class attribute changes are complete, the SNMP manager would set the row status to active, upon which the VC class attribute changes would be committed. Any ATM VC class attribute changes that are made when the row status is 'active' are committed right away.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniAtmVcClassNameId 1.3.6.1.4.1.4874.2.2.8.1.7.1.1.3
The integer identifier associated with this VC class name. The value of this identifier is assigned by the device when an entry in this table is created.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

juniAtmVcClassIdTable 1.3.6.1.4.1.4874.2.2.8.1.7.2
Provides inverse mapping of ATM VC class IDs to ATM VC class names.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVcClassIdEntry

juniAtmVcClassIdEntry 1.3.6.1.4.1.4874.2.2.8.1.7.2.1
A mapping of an integer identifier to an ATM VC class name.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmVcClassIdEntry  

juniAtmVcClassIdId 1.3.6.1.4.1.4874.2.2.8.1.7.2.1.1
The integer identifier associated with this ATM VC class name.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

juniAtmVcClassIdName 1.3.6.1.4.1.4874.2.2.8.1.7.2.1.2
The ATM VC class name having the associated identifier.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..32)  

juniAtmVcClassTable 1.3.6.1.4.1.4874.2.2.8.1.7.3
This table contains Juniper ATM VC Class entries which can be used to specify the ATM PVC attributes either at creation or modification time. A row in this table with default values is created when an entry in juniAtmVcClassNameTable is created.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniAtmVcClassEntry

juniAtmVcClassEntry 1.3.6.1.4.1.4874.2.2.8.1.7.3.1
Each entry contains the attributes of the ATM VC which would be applied to the VC either at creation or modification time when this ATM VC class is associated to it.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniAtmVcClassEntry  

juniAtmVcClassId 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.1
The integer identifier associated with this ATM VC class. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

juniAtmVcClassVccType 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.2
Specifies the encapsulation used by the circuit to carry IP datagrams. Encapsulations are as specified in RFC1483 Multiprotocol Interconnect over ATM. The 'autoconfig' value will recognize both VC Mux and LLC formats. The 'aal5' and 'aal0' values are used for encapsulation methods for transport of ATM frames and cells over IP and MPLS networks when no encapsulation method is specified.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER rfc1483VcMux(0), rfc1483Llc(1), autoconfig(2), aal5(3), aal0(4)  

juniAtmVcClassVccServiceCategory 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.3
Service category for this circuit: ubr Unspecified Bit Rate (best effort). ubrPcr Unspecified Bit Rate with Peak Cell Rate limit. nrtVbr Non-RealTime Variable Bit Rate. cbr Constant Bit Rate. rtVbr Realtime Variable Bit Rate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ubr(0), ubrPcr(1), nrtVbr(2), cbr(3), rtVbr(4)  

juniAtmVcClassVccPcr 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.4
Peak Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmVcClassVccServiceCategory is configured to have one of the following values: ubrPcr nrtVbr cbr rtVbr
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmVcClassVccScr 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.5
Sustained Cell Rate, in kilobits per second (kbps), of this circuit. This parameter is only required when juniAtmVcClassVccServiceCategory is configured to have the following value: nrtVbr rtVbr
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

juniAtmVcClassVccMbs 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.6
Maximum Burst Size, in cells, of this circuit. This parameter is only required when juniAtmVcClassVccServiceCategory is configured to have the following value: nrtVbr rtVbr
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..16777215  

juniAtmVcClassVccOamAdminStatus 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.7
The OAM VC integrity administrative state of the ATM VC associated with this class.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER oamAdminStateDisabled(1), oamAdminStateEnabled(2)  

juniAtmVcClassVccOamLoopbackFrequency 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.8
The OAM loopback frequency in seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..600  

juniAtmVcClassVccOamUpCount 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.9
Specifies the number of successive loopback cell responses to receive before the ATM VC associated with this class is declared up for connectivity verification.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..60  

juniAtmVcClassVccOamDownCount 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.10
Specifies the number of successive loopback cell responses not received before declaring the ATM VC associated with this class as down for connectivity verification.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..60  

juniAtmVcClassVccOamRetryFrequency 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.11
Specifies the frequency (in seconds) to transmit loopback cells when verifying the ATM VC operational state associated with this class (up or down) for connectivity verification.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..600  

juniAtmVcClassVccOamAlarmDownCount 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.12
Specifies the number of successive alarm (AIS or RDI) cells to receive before declaring the ATM VC associated with class as down.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..60  

juniAtmVcClassVccOamAlarmClearTimeout 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.13
Specifies how long to wait (in seconds) before declaring the ATM VC associated with class as up after it has stopped receiving alarm cells.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..60  

juniAtmVcClassVccInverseArp 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.14
Enables the inverse ARP protocol on the ATM VC associated with this class; true(1) enables the protocol, false(2) disables it.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

juniAtmVcClassVccInverseArpRefresh 1.3.6.1.4.1.4874.2.2.8.1.7.3.1.15
The refresh rate in minutes between inverse ARP protocol messages.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..60  

juniAtmTraps 1.3.6.1.4.1.4874.2.2.8.3
OBJECT IDENTIFIER    

juniAtmTrapPrefix 1.3.6.1.4.1.4874.2.2.8.3.0
OBJECT IDENTIFIER    

juniAtmVpPingTestCompleted 1.3.6.1.4.1.4874.2.2.8.3.0.1
Generated at the completion of a AtmfM4VpTest when the corresponding juniAtmVpPingCtlTrapGeneration object has the testCompletion(0) bit set.
Status: current Access: read-write
NOTIFICATION-TYPE    

juniAtmVcPingTestCompleted 1.3.6.1.4.1.4874.2.2.8.3.0.2
Generated at the completion of a AtmfM4VcTest when the corresponding juniAtmVcPingCtlTrapGeneration object has the testCompletion(0) bit set.
Status: current Access: read-write
NOTIFICATION-TYPE    

juniAtmConformance 1.3.6.1.4.1.4874.2.2.8.4
OBJECT IDENTIFIER    

juniAtmCompliances 1.3.6.1.4.1.4874.2.2.8.4.1
OBJECT IDENTIFIER    

juniAtmGroups 1.3.6.1.4.1.4874.2.2.8.4.2
OBJECT IDENTIFIER    

juniAtmCompliance 1.3.6.1.4.1.4874.2.2.8.4.1.1
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added for NBMA map lists and ATM ping.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance2 1.3.6.1.4.1.4874.2.2.8.4.1.2
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added for traffic shapping on VCC subinterfaces.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance3 1.3.6.1.4.1.4874.2.2.8.4.1.3
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added for connection admission control (CAC).
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance4 1.3.6.1.4.1.4874.2.2.8.4.1.4
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when ATM SVC, CAC used bandwidth and sub-interface address objects were added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance5 1.3.6.1.4.1.4874.2.2.8.4.1.5
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when CAC recieve bandwith and E164 public addressing support was added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance6 1.3.6.1.4.1.4874.2.2.8.4.1.6
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when F4 flow OAM circuit config and stats tables were added to the Juniper ATM MIB.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance7 1.3.6.1.4.1.4874.2.2.8.4.1.7
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when the juniAtmLocationGroup was added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance8 1.3.6.1.4.1.4874.2.2.8.4.1.8
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when support was added to export the subinterface description to the line cards.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance9 1.3.6.1.4.1.4874.2.2.8.4.1.9
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement was obsoleted when the juniAtmMartiniGroup was added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance10 1.3.6.1.4.1.4874.2.2.8.4.1.10
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when juniAtmIfCacAvailableBandwidthRx, juniAtmIfE164Autoconversion, juniAtmIfE164Gateway, and juniAtmIfE164OneToOneAddrTrans were deprecated.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance11 1.3.6.1.4.1.4874.2.2.8.4.1.11
Obsolete compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when juniAtmGroup8 was added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance12 1.3.6.1.4.1.4874.2.2.8.4.1.12
The compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when juniAtmVpStatsGroup was added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance13 1.3.6.1.4.1.4874.2.2.8.4.1.13
The compliance statement for entities which implement the Juniper ATM MIB. This statement became obsolete when SVC support was removed.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniAtmCompliance14 1.3.6.1.4.1.4874.2.2.8.4.1.14
The compliance statement for entities which implement the Juniper ATM MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

juniAtmGroup 1.3.6.1.4.1.4874.2.2.8.4.2.1
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when the juniAtmIfMapGroup object was added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmAal5Group 1.3.6.1.4.1.4874.2.2.8.4.2.2
A collection of objects providing management of AAL5 interfaces in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmSubIfGroup 1.3.6.1.4.1.4874.2.2.8.4.2.3
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when juniAtmSubIfNbma, juniAtmSubIfInverseArp, and juniAtmSubIfInverseArpRefresh were added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmVpTunnelGroup 1.3.6.1.4.1.4874.2.2.8.4.2.4
A collection of objects providing management of VP tunnels in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmNbmaMapGroup 1.3.6.1.4.1.4874.2.2.8.4.2.5
A collection of object providing management of NBMA in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmSubIfGroup2 1.3.6.1.4.1.4874.2.2.8.4.2.6
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when juniAtmSubIfAddress was added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmVpPingControlGroup 1.3.6.1.4.1.4874.2.2.8.4.2.7
A collection of object providing management of ATM VPL Ping testing in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmVcPingControlGroup 1.3.6.1.4.1.4874.2.2.8.4.2.8
A collection of object providing management of ATM VCL Ping testing in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmPingTrapGroup 1.3.6.1.4.1.4874.2.2.8.4.2.9
A collection of notifications supporting ATM Ping testing in a Juniper product.
Status: current Access: read-write
NOTIFICATION-GROUP    

juniAtmGroup2 1.3.6.1.4.1.4874.2.2.8.4.2.10
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when support was added for connection admission control (CAC).
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmTrafficShapingGroup 1.3.6.1.4.1.4874.2.2.8.4.2.11
A collection of objects providing management of ATM traffic shaping in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmGroup3 1.3.6.1.4.1.4874.2.2.8.4.2.12
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when support was added for connection admission control (CAC) used bandwidth.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmGroup4 1.3.6.1.4.1.4874.2.2.8.4.2.13
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when CAC recieve bandwith and E164 public addressing objects were added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmSvcGroup 1.3.6.1.4.1.4874.2.2.8.4.2.14
Obsolete collection of objects providing management of ATM SVC interfaces in a Juniper product. This group became obsolete when E164 public addressing support was added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmSubIfGroup3 1.3.6.1.4.1.4874.2.2.8.4.2.15
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when juniAtmSubIfMtu was added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmGroup5 1.3.6.1.4.1.4874.2.2.8.4.2.16
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when ATM VP description support was added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmSvcGroup2 1.3.6.1.4.1.4874.2.2.8.4.2.17
A collection of objects providing management of ATM SVC interfaces in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmPnniGroup 1.3.6.1.4.1.4874.2.2.8.4.2.18
A collection of objects providing management of PNNI Routing Control Channels in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmSubIfGroup4 1.3.6.1.4.1.4874.2.2.8.4.2.19
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when support was added to export the subinterface description to the line cards.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmF4OamCircuitGroup 1.3.6.1.4.1.4874.2.2.8.4.2.20
Obsolete collection of objects providing management of ATM F4 flow OAM circuits in a Juniper product.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmGroup6 1.3.6.1.4.1.4874.2.2.8.4.2.21
Obsolete collection of objects providing management of ATM interfaces in a Juniper product. This group became obsolete when bulk-configuration profile override support was added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmLocationGroup 1.3.6.1.4.1.4874.2.2.8.4.2.22
A collection of objects providing interface location information in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmSubIfGroup5 1.3.6.1.4.1.4874.2.2.8.4.2.23
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmMartiniGroup 1.3.6.1.4.1.4874.2.2.8.4.2.24
A collection of objects providing ATM Martini cell aggregation configuration.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmGroup7 1.3.6.1.4.1.4874.2.2.8.4.2.25
Obsolete collection of objects providing management of ATM interfaces in a Juniper product.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmGroup8 1.3.6.1.4.1.4874.2.2.8.4.2.26
A collection of objects providing management of ATM interfaces in a Juniper product.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmVpStatsGroup 1.3.6.1.4.1.4874.2.2.8.4.2.27
A collection of objects providing ATM VP level statistics.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmSubIfGroup6 1.3.6.1.4.1.4874.2.2.8.4.2.28
Obsolete collection of objects providing management of ATM subinterfaces in a Juniper product. This group became obsolete when ATM SVC support was removed.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniAtmF4OamCircuitGroup2 1.3.6.1.4.1.4874.2.2.8.4.2.29
A collection of objects providing management of ATM F4 flow OAM circuits in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmGroup9 1.3.6.1.4.1.4874.2.2.8.4.2.30
A collection of objects providing management of ATM interfaces in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmSubIfGroup7 1.3.6.1.4.1.4874.2.2.8.4.2.31
A collection of objects providing management of ATM subinterfaces in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniAtmVcClassGroup 1.3.6.1.4.1.4874.2.2.8.4.2.32
A collection of objects providing management of ATM VC class in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP