LIEBERT-GP-NOTIFICATIONS-MIB

File: LIEBERT-GP-NOTIFICATIONS-MIB.mib (14243 bytes)

Imported modules

RFC1213-MIB SNMPv2-SMI LIEBERT-GP-REGISTRATION-MIB
LIEBERT-GP-CONDITIONS-MIB

Imported symbols

sysUpTime MODULE-IDENTITY OBJECT-IDENTITY
OBJECT-TYPE NOTIFICATION-TYPE lgpNotifications
liebertNotificationsModuleReg lgpConditionId lgpConditionDescr
lgpConditionTime lgpConditionTableRef lgpConditionTableRowRef

Defined Values

liebertGlobalProductsNotificationsModule 1.3.6.1.4.1.476.1.42.1.4.1
The MIB module used to register Liebert SNMP OIDs. Copyright 2000-2008 Liebert Corporation. All rights reserved. Reproduction of this document is authorized on the condition that the forgoing copyright notice is included. This Specification is supplied 'AS IS' and Liebert Corporation makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
MODULE-IDENTITY    

lgpEventNotifications 1.3.6.1.4.1.476.1.42.3.3.0
Notifications for Liebert Global Products.
Status: current Access: read-only
OBJECT-IDENTITY    

lgpEventParameters 1.3.6.1.4.1.476.1.42.3.3.10
This sub tree describes various parameters/data that are carried in the payload of some notifications.
Status: current Access: read-only
OBJECT-IDENTITY    

lgpEventParmTableRef 1.3.6.1.4.1.476.1.42.3.3.10.5
This object will be included as a varbind in some lgpEventNotifications. It is a reference to a table object in the MIB. The value of this object will be the OID of a table that the object that the notification applies to is defined. The notification containing this object will also contain a varbind 'lgpEventParmTableRowRef' that will specify which instance (row) in the table the object is defined in. Example: NOTIFICATION: lgpEventConditionEntryAdded varbind: lgpConditionId 6 varbind: lgpConditionDescr lgpConditionRcpBranchBreakerOpen varbind: lgpConditionTime 393884848 varbind: lgpEventParmTableRef lgpPduRbTable varbind: lgpEventParmTableRowRef lgpPduRbEntryId.1.4 In the above example the breaker opened for a Receptacle branch. The specific receptacle branch is specified by the additional varbind (lgpEventParmTableRowRef). In this case the notification is for the 4th receptacle branch on the 1st PDU in the PDU cluster.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

lgpEventParmTableRowRef 1.3.6.1.4.1.476.1.42.3.3.10.6
This is a reference to the intersection of a row and column (cell) in the table specified by the companion varbind (lgpEventParmTableRef) in this notification. The row in the table where this cell exists represents the object that this notification applies to. Example: NOTIFICATION: lgpEventRcpPowerStateChangeOff varbind: sysUpTime 393885975 varbind: lgpEventParmTableRef lgpPduRcpTable varbind: lgpEventParmTableRowRef lgpPduRcpEntryId.2.4.5 In the above example the power state changed for a Receptacle. The table containing the definition of the receptacle (lgpPduRcpTable) is given by the varbind (lgpEventParmTableRef) The specific receptacle is specified by the varbind (lgpEventParmTableRowRef). In this case the notification is for the 5th receptacle on the 4th receptacle branch on the 2nd PDU in the PDU cluster. If one wanted to retrieve the user assigned label for this receptacle the OID would be: lgpPduRcpEntryUsrLabel.2.4.5
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

lgpEventConditionEntryAdded 1.3.6.1.4.1.476.1.42.3.3.0.1
This notification is sent each time a condition is inserted into the conditions table.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventConditionEntryRemoved 1.3.6.1.4.1.476.1.42.3.3.0.2
This notification is sent each time a condition is removed from the conditions table.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventLowBatteryWarning 1.3.6.1.4.1.476.1.42.3.3.0.3
The battery's remaining charge is less than or equal to the agent's configured low threshold 'lgpPwrConfigLowBatteryWarningTime'.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventLoadTransferedToBypass 1.3.6.1.4.1.476.1.42.3.3.0.4
The device has transferred the load to the bypass source.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventInternalFault 1.3.6.1.4.1.476.1.42.3.3.0.5
The device has reported an internal fault.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventBatteryTestFailed 1.3.6.1.4.1.476.1.42.3.3.0.6
The device has reported a battery self-test failure.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventOutputOverload 1.3.6.1.4.1.476.1.42.3.3.0.7
The device has reported an output overload condition.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventEstablishedPowerRedundancy 1.3.6.1.4.1.476.1.42.3.3.0.8
The device has transitioned to the user defined redundant state.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventLostPowerRedundancy 1.3.6.1.4.1.476.1.42.3.3.0.9
The device as transitioned to a non-redundant power state as defined by the user configured threshold.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventPowerModuleFailure 1.3.6.1.4.1.476.1.42.3.3.0.10
Device power module failure.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventBatteryModuleFailure 1.3.6.1.4.1.476.1.42.3.3.0.11
Device battery module failure.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventControlModuleFailure 1.3.6.1.4.1.476.1.42.3.3.0.12
Device control module failure.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventPowerModuleWarning 1.3.6.1.4.1.476.1.42.3.3.0.13
Device power module warning.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventBatteryModuleWarning 1.3.6.1.4.1.476.1.42.3.3.0.14
Device battery module warning.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventControlModuleWarning 1.3.6.1.4.1.476.1.42.3.3.0.15
Device control module warning.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventAgentFirmwareUpdateSuccessful 1.3.6.1.4.1.476.1.42.3.3.0.16
The firmware update to the agent card has completed successfully. This element has been relocated to lgpAgentFirmwareUpdateSuccessful in the LIEBERT-GP-AGENT-MIB document.
Status: deprecated Access: read-only
NOTIFICATION-TYPE    

lgpEventAgentFirmwareCorrupt 1.3.6.1.4.1.476.1.42.3.3.0.17
The firmware update to the agent card has failed and the firmware is now corrupt. This element has been relocated to lgpAgentFirmwareCorrupt in the LIEBERT-GP-AGENT-MIB document.
Status: deprecated Access: read-only
NOTIFICATION-TYPE    

lgpEventConfigModified 1.3.6.1.4.1.476.1.42.3.3.0.18
Configuration for the referenced PDU has been modified.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventModuleAdded 1.3.6.1.4.1.476.1.42.3.3.0.19
A hot-swappable module has been added to the object specified by the lgpEventParmTableRef and lgpEventParmTableRowRef.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventModuleRemoved 1.3.6.1.4.1.476.1.42.3.3.0.20
A hot-swappable module has been removed from the object specified by the lgpEventParmTableRef and lgpEventParmTableRowRef.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventRcpPowerStateChangeOn 1.3.6.1.4.1.476.1.42.3.3.0.21
Receptacle's power state has been changed from OFF to ON.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventRcpPowerStateChangeOff 1.3.6.1.4.1.476.1.42.3.3.0.22
Receptacle's power state has been changed from ON to OFF.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventRcpLoadAdded 1.3.6.1.4.1.476.1.42.3.3.0.23
The receptacle's load started drawing power. This notification is asserted when the receptacle power is ON and the associated load was previously not drawing power but is now drawing power. This event is not asserted as a result of turning the receptacle power ON.
Status: current Access: read-only
NOTIFICATION-TYPE    

lgpEventRcpLoadRemoved 1.3.6.1.4.1.476.1.42.3.3.0.24
The receptacle's load stopped drawing power. This notification is asserted when the receptacle power is ON and the associated load was previously drawing power but is now no longer drawing power. This event is not asserted as a result of turning the receptacle power OFF.
Status: current Access: read-only
NOTIFICATION-TYPE