LIVINGSTON-PM4-MIB

File: LIVINGSTON-PM4-MIB.mib (100407 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB LIVINGSTON-ROOT-MIB

Imported symbols

IpAddress Counter Gauge
TimeTicks OBJECT-TYPE TRAP-TYPE
DisplayString PhysAddress sysName
lucentPM4

Defined Types

PMUnitType  
INTEGER mrgmodule(1), quadt1(2), trie1(3), modem(4), serialport(5), ether0(6), ether1(7), console(8), acpwrsup(9), fan(10), dcpwrsup(11), allunits(255)    

PMEquipPRIStatus  
INTEGER up(1), down(2), loopback(3), fault(4)    

PMEquipStatus  
INTEGER up(1), down(2), maintenance(3), fault(4), other(5)    

PMDiagCmdStatus  
INTEGER success(1), fail(2), inprogress(3), notsupported(4), aborted(5), other(6)    

PMDiagTestCntrl  
INTEGER normal(1), start(2), stop(3), abort(4)    

PMAlarmType  
INTEGER informational(1), warning(2), minor(3), major(4), critical(5)    

LucentPM4ChasCmdEntry  
SEQUENCE    
  lucentPM4ChasCmdIndex INTEGER
  lucentPM4ChasCmdBoardId INTEGER
  lucentPM4ChasCmdUnitType PMUnitType
  lucentPM4ChasCmdUnitIndex INTEGER
  lucentPM4ChasCmdDevId INTEGER
  lucentPM4ChasCmdId INTEGER
  lucentPM4ChasCmdParams OCTET STRING
  lucentPM4ChasCmdResult INTEGER

LucentPM4SerialEntry  
SEQUENCE    
  lucentPM4SerialBoardIndex INTEGER
  lucentPM4SerialUnitType PMUnitType
  lucentPM4SerialIndex INTEGER
  lucentPM4ModemId INTEGER
  lucentPM4SerialPortNumber INTEGER
  lucentPM4SerialPhysType INTEGER
  lucentPM4SerialPortStatus INTEGER
  lucentPM4SerialDS0State INTEGER
  lucentPM4SerialUser DisplayString
  lucentPM4SerialSessionId DisplayString
  lucentPM4SerialTypeHardwired INTEGER
  lucentPM4SerialTypeNwDialIn INTEGER
  lucentPM4SerialTypeNwDialout INTEGER
  lucentPM4SerialTypeLogin INTEGER
  lucentPM4SerialTypeDevice INTEGER
  lucentPM4SerialTypeDeviceName DisplayString
  lucentPM4SerialDirection INTEGER
  lucentPm4SerialStarted TimeTicks
  lucentPM4SerialIdle TimeTicks
  lucentPM4SerialInSpeed Gauge
  lucentPM4SerialOutSpeed Gauge
  lucentPM4SerialIpAddress IpAddress
  lucentPM4SerialifDescr DisplayString
  lucentPM4SerialInOctets Counter
  lucentPM4SerialOutOctets Counter
  lucentPm4SerialQOctets Counter

LucentPM4T1E1Entry  
SEQUENCE    
  lucentPM4T1E1BoardIndex INTEGER
  lucentPM4T1E1UnitType PMUnitType
  lucentPM4T1E1Index INTEGER
  lucentPM4T1E1SerialIndex INTEGER
  lucentPM4T1E1SerialCount INTEGER
  lucentPM4T1E1PhysType INTEGER
  lucentPM4T1E1Status INTEGER
  lucentPM4T1E1Function INTEGER
  lucentPM4T1E1Framing INTEGER
  lucentPM4T1E1Encoding INTEGER
  lucentPM4T1E1PCM INTEGER
  lucentPM4T1E1SuperSignal INTEGER
  lucentPM4T1E1StartMode INTEGER
  lucentPM4T1E1ChangeTime TimeTicks
  lucentPM4T1E1RecvLevel Gauge
  lucentPM4T1E1BlueAlarms Counter
  lucentPM4T1E1YellowAlarms Counter
  lucentPM4T1E1CarrierLoss Counter
  lucentPM4T1E1SyncLoss Counter
  lucentPM4T1E1BipolarErrors Counter
  lucentPM4T1E1CRCErrors Counter
  lucentPM4T1E1SyncErrors Counter

LucentPM4ModemEntry  
SEQUENCE    
  lucentPM4ModemBoardIndex INTEGER
  lucentPM4ModemUnitType PMUnitType
  lucentPM4ModemIndex INTEGER
  lucentPM4ModemPortName DisplayString
  lucentPM4ModemStatus INTEGER
  lucentPM4ModemProtocol INTEGER
  lucentPM4ModemCompression INTEGER
  lucentPM4ModemInSpeed Gauge
  lucentPM4ModemOutSpeed Gauge
  lucentPM4ModemInByteCount Counter
  lucentPM4ModemOutByteCount Counter
  lucentPM4ModemRetrains Counter
  lucentPM4ModemRenegotiates Counter
  lucentPM4ModemCalls Counter
  lucentPM4ModemDetects Counter
  lucentPM4ModemConnects Counter

LucentPM4EtherEntry  
SEQUENCE    
  lucentPM4EtherBoardIndex INTEGER
  lucentPM4EtherIfType PMUnitType
  lucentPM4EtherIndex INTEGER
  lucentPM4EtherIfIndex INTEGER
  lucentPM4EtherPortName DisplayString
  lucentPM4EtherMacAddr PhysAddress
  lucentPM4EtherIPAddr IpAddress
  lucentPM4EtherIPGateway IpAddress
  lucentPM4EtherPriNameServer IpAddress
  lucentPM4EtherAltNameServer IpAddress
  lucentPM4EtherSubnetMask IpAddress
  lucentPM4EtherInFilter DisplayString
  lucentPM4EtherOutFilter DisplayString
  lucentPM4EtherOptRip INTEGER
  lucentPM4EtherOptSlip INTEGER
  lucentPM4EtherOptEtherDown INTEGER
  lucentPM4EtherOptBcastHigh INTEGER
  lucentPM4EtherOptSnmp INTEGER
  lucentPM4EtherOptNoListen INTEGER
  lucentPM4EtherOptDefaultRip INTEGER
  lucentPM4EtherOptDefaultListen INTEGER
  lucentPM4EtherOptIPFilter INTEGER
  lucentPM4EtherOptDns INTEGER
  lucentPM4EtherOptPmeMsg INTEGER
  lucentPM4EtherOptNoClip INTEGER
  lucentPM4EtherOptEtherIpx INTEGER
  lucentPM4EtherOptNetBIOS INTEGER
  lucentPM4EtherOptAccounting INTEGER
  lucentPM4EtherOptNoPAP INTEGER

LucentPM4FMChasTrapEntry  
SEQUENCE    
  lucentPM4FMChasTrapIndex INTEGER
  lucentPM4FMChasBoardID INTEGER
  lucentPM4FMChasTrapUnitType PMUnitType
  lucentPM4FMChasTrapUnitIndex INTEGER
  lucentPM4FMChasTrapStatus INTEGER
  lucentPM4FMChasTrapSeverity INTEGER
  lucentPM4FMChasTrapTimeStamp TimeTicks
  lucentPM4FMChasTrapState INTEGER

LucentPM4FMEqpTrapCfgEntry  
SEQUENCE    
  lucentPM4FMEqpBoardIndex INTEGER
  lucentPM4FMEqpUnitType PMUnitType
  lucentPM4FMEqpunitIndex INTEGER
  lucentPM4FMEqpTrapId INTEGER
  lucentPM4FMEqpTrapCtl INTEGER
  lucentPM4FMEqpTrapRepTimer INTEGER

LucentPM4FMThreshT1E1TrapCfgEntry  
SEQUENCE    
  lucentPM4FMT1E1ThreshBoardIndex INTEGER
  lucentPM4FMT1E1ThreshUnitType INTEGER
  lucentPM4FMT1E1ThreshUnitIndex INTEGER
  lucentPM4FMT1E1ThreshESs Gauge
  lucentPM4FMT1E1ThreshSESs Gauge
  lucentPM4FMT1E1ThreshSEFSs Gauge
  lucentPM4FMT1E1ThreshUASs Gauge
  lucentPM4FMT1E1ThreshCSSs Gauge
  lucentPM4FMT1E1ThreshPCVs Gauge
  lucentPM4FMT1E1ThreshLESs Gauge
  lucentPM4FMT1E1ThreshBESs Gauge
  lucentPM4FMT1E1ThreshDMs Gauge
  lucentPM4FMT1E1ThreshTrapRepTimer INTEGER
  lucentPM4FMT1E1ThreshTrapAck INTEGER

LucentPM4FMEnvTrapCfgEntry  
SEQUENCE    
  lucentPM4FMEnvBoardID INTEGER
  lucentPM4FMEnvUnitType PMUnitType
  lucentPM4FMEnvUnitIndex INTEGER
  lucentPM4FMEnvOptUnitTemp INTEGER
  lucentPM4FMEnvUnitTempRange INTEGER
  lucentPM4FMEnvOptUnitPwrLvl INTEGER
  lucentPM4FMEnvUnitPwrRange INTEGER
  lucentPM4FMEnvTrapCtl INTEGER
  lucentPM4FMEnvTrapRepTimer INTEGER

LucentPM4T1E1PMCurEntry  
SEQUENCE    
  lucentPM4T1E1PMCurBoardID INTEGER
  lucentPM4T1E1PMCurUnitType PMUnitType
  lucentPM4T1E1PMCurLineNum INTEGER
  lucentPM4T1E1PMCurIfIndex INTEGER
  lucentPM4T1E1PMCurESs Gauge
  lucentPM4T1E1PMCurSESs Gauge
  lucentPM4T1E1PMCurSEFs Gauge
  lucentPM4T1E1PMCurUASs Gauge
  lucentPM4T1E1PMCurCSSs Gauge
  lucentPM4T1E1PMCurPCVs Gauge
  lucentPM4T1E1PMCurLESs Gauge
  lucentPM4T1E1PMCurBESs Gauge
  lucentPM4T1E1PMCurDMs Gauge
  lucentPM4T1E1PMCurLCVs Gauge

LucentPM4T1E1PMIntEntry  
SEQUENCE    
  lucentPM4T1E1PMIntBoard INTEGER
  lucentPM4T1E1PMIntUnitType PMUnitType
  lucentPM4T1E1PMIntLineNum INTEGER
  lucentPM4T1E1PMIntIfIndex INTEGER
  lucentPM4T1E1PMIntInterval INTEGER
  lucentPM4T1E1PMIntESs Gauge
  lucentPM4T1E1PMIntSESs Gauge
  lucentPM4T1E1PMIntSEFs Gauge
  lucentPM4T1E1PMIntUASs Gauge
  lucentPM4T1E1PMIntCSSs Gauge
  lucentPM4T1E1PMIntPCVs Gauge
  lucentPM4T1E1PMIntLESs Gauge
  lucentPM4T1E1PMIntBESs Gauge
  lucentPM4T1E1PMIntDMs Gauge
  lucentPM4T1E1PMIntLCVs Gauge

LucentPM4T1E1PMTotalEntry  
SEQUENCE    
  lucentPM4T1E1PMTotalBoard INTEGER
  lucentPM4T1E1PMTotalUnitType PMUnitType
  lucentPM4T1E1PMTotalLineNum INTEGER
  lucentPM4T1E1PMTotalIfIndex INTEGER
  lucentPM4T1E1PMTotalESs Gauge
  lucentPM4T1E1PMTotalSESs Gauge
  lucentPM4T1E1PMTotalSEFs Gauge
  lucentPM4T1E1PMTotalUASs Gauge
  lucentPM4T1E1PMTotalCSSs Gauge
  lucentPM4T1E1PMTotalPCVs Gauge
  lucentPM4T1E1PMTotalLESs Gauge
  lucentPM4T1E1PMTotalBESs Gauge
  lucentPM4T1E1PMTotalDMs Gauge
  lucentPM4T1E1PMTotalLCVs Gauge

LucentPM4SnmpCommEntry  
SEQUENCE    
  lucentPM4SnmpCommIndex INTEGER
  lucentPM4SnmpCommName DisplayString
  lucentPM4SnmpCommIpAddr IpAddress
  lucentPM4SnmpCommReadAccess INTEGER
  lucentPM4SnmpCommWriteAccess INTEGER
  lucentPM4SnmpCommTraps INTEGER
  lucentPM4SnmpCommStatus INTEGER
  lucentPM4SnmpCommLastError DisplayString

LucentPM4AMCallEventEntry  
SEQUENCE    
  lucentPM4AMCEIndex INTEGER
  lucentPM4AMCETimeStamp INTEGER
  lucentPM4AMCEType INTEGER
  lucentPM4AMCESvcType INTEGER
  lucentPM4AMCEUName DisplayString
  lucentPM4AMCEModemBoard INTEGER
  lucentPM4AMCEModemID INTEGER
  lucentPM4AMCEModemPort DisplayString
  lucentPM4AMCEDataRate INTEGER
  lucentPM4AMCECallingPartyID DisplayString
  lucentPM4AMCECalledPartyID DisplayString
  lucentPM4AMCEInOctets INTEGER
  lucentPM4AMCEOutOctets INTEGER
  lucentPM4AMCECallCharge INTEGER
  lucentPM4AMCEDisconnReason INTEGER

Defined Values

lucentPM4Mib 1.3.6.1.4.1.307.1.1.2.1
OBJECT IDENTIFIER    

lucentPM4Traps 1.3.6.1.4.1.307.1.1.2.2
OBJECT IDENTIFIER    

lucentPM4MibRev 1.3.6.1.4.1.307.1.1.2.1.1
This object specifies the current MIB revision number. Example of the MIB revision can be PM4xxx for PM4 product and PM3xxx for PM3 products etc. Where xxx can be any combination of alpha-numeric characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..6)  

lucentPM4SWRev 1.3.6.1.4.1.307.1.1.2.1.2
This object specifies the ComOS revision number. Example of the ComOS revision can be ComOS4.xx. Where xxx can be any combination of alpha-numeric characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..10)  

lucentPM4Chassis 1.3.6.1.4.1.307.1.1.2.1.3
OBJECT IDENTIFIER    

lucentPM4ChasSummary 1.3.6.1.4.1.307.1.1.2.1.3.1
This object provides general information about the PortMaster 4 chassis operational status. This object is read-only. The DisplayString represents a summary of all the devices in the chassis as follows: Bytes 1 - 2 '0''0' Byte 3 'U', 'D', 'M', 'F', 'O' Byte 4 space Bytes 5 - 6 '0''1' Byte 7 'U', 'D', 'M', 'F', 'O' Byte 8 space Bytes 9 - 10 '0''2' Byte 11 'U', 'D', 'M', 'F', 'O' Byte 12 space Bytes 13 - 14 '0''3' Byte 15 'U', 'D', 'M', 'F', 'O' Byte 16 space Bytes 17 - 18 '0''4' Byte 19 'U', 'D', 'M', 'F', 'O' Byte 20 space Bytes 21 - 22 '0''5' Byte 23 'U', 'D', 'M', 'F', 'O' Byte 24 space Bytes 25 - 26 '0''6' Byte 27 'U', 'D', 'M', 'F', 'O' Byte 28 space Bytes 29 - 30 '0''7' Byte 31 'U', 'D', 'M', 'F', 'O' Byte 32 space Bytes 33 - 34 '0''8' Byte 35 'U', 'D', 'M', 'F', 'O' Byte 36 space Bytes 37 - 38 '0''9' Byte 39 'U', 'D', 'M', 'F', 'O' Byte 40 space Bytes 41 - 42 '1''0' Byte 43 'U', 'D', 'M', 'F', 'O' Byte 44 space Bytes 45 - 46 '1''1' Byte 47 'U', 'D', 'M', 'F', 'O' Byte 48 space Bytes 49 - 50 '1''2' Byte 51 'U', 'D', 'M', 'F', 'O' Byte 52 space Bytes 53 - 54 '1''3' Byte 55 'U', 'D', 'M', 'F', 'O' Byte 56 space Bytes 57 - 58 '1''4' Byte 59 'U', 'D', 'M', 'F', 'O' Byte 60 space Bytes 61 - 62 '1''5' Byte 63 'U', 'D', 'M', 'F', 'O' Byte 64 space Bytes 65 - 66 'P''1' Byte 67 'U', 'D', 'M', 'F', 'O' Byte 68 space Bytes 69 - 70 'P''2' Byte 71 'U', 'D', 'M', 'F', 'O' Byte 72 space Bytes 73 - 74 'P''3' Byte 75 'U', 'D', 'M', 'F', 'O' Byte 76 space Bytes 77 - 78 'D''1' Byte 79 'U', 'D', 'M', 'F', 'O' Byte 80 space Bytes 81 - 82 'D''2' Byte 83 'U', 'D', 'M', 'F', 'O' Byte 84 space Bytes 85 - 86 'F''1' Byte 87 'U', 'D', 'M', 'F', 'O' Byte 88 space Bytes 89 - 90 'F''2' Byte 91 'U', 'D', 'M', 'F', 'O' Byte 92 space Bytes 93 - 94 'F''3' Byte 95 'U', 'D', 'M', 'F', 'O' Byte 96 space Bytes 97 - 98 'F''4' Byte 99 'U', 'D', 'M', 'F', 'O' Legend '#''#' Represents the board number 'F''#' Represents the Fan # 'P''#' Represents the Power Supply # 'D''#' Represents the DC Power Supply # 'U' Up 'D' Down 'M' Maintenance 'F' Failed 'O' Other unknown state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(55)  

lucentPM4ChasCmdTable 1.3.6.1.4.1.307.1.1.2.1.3.2
Table describing the commands that can be issued to the agent to perform specific actions to any card, port or device in the system. For example to erase the flash or a particular file from the flash. Note that only a station configured with the appropriate authentication string can issue commands to the agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4ChasCmdEntry

lucentPM4ChasCmdEntry 1.3.6.1.4.1.307.1.1.2.1.3.2.1
Entries in the command table for the chassis commands. This describes one entry or row in the command table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4ChasCmdEntry  

lucentPM4ChasCmdIndex 1.3.6.1.4.1.307.1.1.2.1.3.2.1.1
This object specifies the index in the command table. The values for this object is limited to the size of the command table on the network element. The size of the command table is set to 10 which can be changed if and when users need to schedule more than 10 commands at a given time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..10  

lucentPM4ChasCmdBoardId 1.3.6.1.4.1.307.1.1.2.1.3.2.1.2
This object specifies the board for which the command is to be applied. The values for this object is limited to the Max number of boards.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

lucentPM4ChasCmdUnitType 1.3.6.1.4.1.307.1.1.2.1.3.2.1.3
This object specifies the type of the device to which this command must apply.
Status: mandatory Access: read-write
OBJECT-TYPE    
  PMUnitType  

lucentPM4ChasCmdUnitIndex 1.3.6.1.4.1.307.1.1.2.1.3.2.1.4
This object specifies the interface index.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

lucentPM4ChasCmdDevId 1.3.6.1.4.1.307.1.1.2.1.3.2.1.5
This object specifies the sub-unit id for which the command must be applied to. This value will be used by the agent to index to the correct sub-device on a board. For example, this object can have values from 1 - 96 for the modems or 1 - 4 for T1 or 1 - 3 for the E1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..96  

lucentPM4ChasCmdId 1.3.6.1.4.1.307.1.1.2.1.3.2.1.6
This object specifies the command. Each command takes a unique value. The completion status of this command is set in the result object of the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER eraseflashfile(1), eraseallflash(2), saveall(3), resetport(4), resetfilter(5), adduser(6), deleteuser(7), addlocation(8), diallocation(9), addfilter(10), deletefilter(11), addmodem(12), resetvirtport(13), addospfarea(14), resetospf(15), addprop(16), deleteprop(17), resetprop(18), resetether0(19), resetether1(20), resetall(21), resetconsole(22), version(23), traceroutes(24), ptrace(25), ifconfig(26), eraseconfig(27), erasecomos(28), reboot(29)  

lucentPM4ChasCmdParams 1.3.6.1.4.1.307.1.1.2.1.3.2.1.7
This object specifies the command parameters. Each parameter must be seperated by a blank space. The last parameter is terminated with a ';'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

lucentPM4ChasCmdResult 1.3.6.1.4.1.307.1.1.2.1.3.2.1.8
This object specifies the command result. The result for each of the previous 10 commands will be stored in a table, which can be retrieved by the client when needed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMDiagCmdStatus  

lucentPM4ConfigMgmt 1.3.6.1.4.1.307.1.1.2.1.4
OBJECT IDENTIFIER    

lucentPM4CmInterfaces 1.3.6.1.4.1.307.1.1.2.1.4.1
OBJECT IDENTIFIER    

lucentPM4CmSerial 1.3.6.1.4.1.307.1.1.2.1.4.1.1
OBJECT IDENTIFIER    

lucentPM4SerialTable 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1
A list of serial interface entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4SerialEntry

lucentPM4SerialEntry 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1
A serial interface entry containing objects at the physical and session layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4SerialEntry  

lucentPM4SerialBoardIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.1
A unique value for each board in the PortMaster chassis. The Max value of this variable is limited by the number of boards in the chassis. This value is limited to 255.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4SerialUnitType 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.2
Unit type indicates the serial port. The interface table ifIndex is a combination of board index, unit type and unit index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMUnitType  

lucentPM4SerialIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.3
A unique value for each serial interface on a given board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4ModemId 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.4
This object is the cross reference to the modem interface table index. The value is dynamically assigned when the call is established.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4SerialPortNumber 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.5
A serial port to which this modem is assigned for this call.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4SerialPhysType 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.6
The type of physical serial interface, distinguished according to the physical/link protocol(s) being currently used on the interface. When this object is set to asyn(2), then the service types dial-in, dial- out, login, and device are valid. When this object is set to sync(3), the serial service types dial-in, dial- out and hardwired are valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), async(2), sync(3), isdn(4)  

lucentPM4SerialPortStatus 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.7
The status of the serial interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), connecting(2), established(3), disconnecting(4), command(5), noservice(6)  

lucentPM4SerialDS0State 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.8
Cross reference value for each DS0 for a given T1/E1 line and a given board in the PM4 chassis.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notavailable(1), busyout(2), havecomport(3)  

lucentPM4SerialUser 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.9
Name of the active user. Blank if not active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

lucentPM4SerialSessionId 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.10
A unique Session Identifier which matches the RADIUS session ID. Blank when not using RADIUS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

lucentPM4SerialTypeHardwired 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.11
The active type of service being provided by the serial interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4SerialTypeNwDialIn 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.12
The active type of service being provided by the serial interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4SerialTypeNwDialout 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.13
The active type of service being provided by the serial interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4SerialTypeLogin 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.14
The active type of service being provided by the serial interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4SerialTypeDevice 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.15
The active type of service being provided by the serial interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4SerialTypeDeviceName 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.16
Device name if the lucentPM4SerialTypeDevice is enabled. This is a string of characters (e.g. /dev/tty1) indicating the device name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

lucentPM4SerialDirection 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.17
The direction the active session was initiated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER in(1), out(2), inout(3)  

lucentPM4SerialStarted 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.18
The amount of time this session has been active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

lucentPM4SerialIdle 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.19
The amount of time this session has been idle.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

lucentPM4SerialInSpeed 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.20
An estimate of the serial interface's current inbound bandwidth in bits per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4SerialOutSpeed 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.21
An estimate of the serial interface's current outbound bandwidth in bits per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4SerialIpAddress 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.22
The IP address associated with the serial interface. If being used as a network type port, this is the remote user's IP address. If being used as a device or login, this is the IP address of the host the user is connected to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

lucentPM4SerialifDescr 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.23
A textual string containing information about the network interface bound to the serial interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

lucentPM4SerialInOctets 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.24
The total number of octets received on the serial interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4SerialOutOctets 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.25
The total number of octets transmitted on the serial interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4SerialQOctets 1.3.6.1.4.1.307.1.1.2.1.4.1.1.1.1.26
The total number of octets queued on the serial interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4CmT1E1 1.3.6.1.4.1.307.1.1.2.1.4.1.2
OBJECT IDENTIFIER    

lucentPM4T1E1Table 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1
A list of T1/E1 interface entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4T1E1Entry

lucentPM4T1E1Entry 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1
A T1/E1 entry containing objects at the physical layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4T1E1Entry  

lucentPM4T1E1BoardIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.1
A unique value for each board in the PM4 chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1UnitType 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.2
This object specifies the type of the unit as the T1/E1 line. This value is a part of the interface table ifIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMUnitType  

lucentPM4T1E1Index 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.3
A unique value for each T1/E1 interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1SerialIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.4
The value of the instance for the serial port. This object provides a cross reference from the T1/E1 interface to the serial port to which it is mapped.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1SerialCount 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.5
The number of serial ports assigned to this interface. If this is a Channelized T1/E1, then the count is 24/32. If this is a fractional T1/E1, then the count can be any number between 1 and a number less than 24/32.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PhysType 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.6
The type of interface (T1 or E1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER t1(1), e1(2)  

lucentPM4T1E1Status 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.7
The current operational status of the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMEquipPRIStatus  

lucentPM4T1E1Function 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.8
The configured function of the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER isdn(1), channelized(2), clear(3), fractional(4), isdnfrac(5)  

lucentPM4T1E1Framing 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.9
The configured line framing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER esf(1), d4(2), crc4(3), fas(4)  

lucentPM4T1E1Encoding 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.10
The configured line signal encoding.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ami(1), b8zs(2), hdb3(3)  

lucentPM4T1E1PCM 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.11
The configured voice modulation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ulaw(1), alaw(2)  

lucentPM4T1E1SuperSignal 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.12
The configured supervisory signalling mode for this interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER em(1), groundstart(2)  

lucentPM4T1E1StartMode 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.13
The configured start mode for this interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wink(1), immediate(2)  

lucentPM4T1E1ChangeTime 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.14
The amount of time since the last status change.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

lucentPM4T1E1RecvLevel 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.15
An estimate of the serial interface's current recieve signal level in DB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1BlueAlarms 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.16
The total number of Blue Alarms on the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4T1E1YellowAlarms 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.17
The total number of Yellow Alarms on the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4T1E1CarrierLoss 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.18
The total number of times the interface has lost carrier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4T1E1SyncLoss 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.19
The total number of times the interface has lost frame synchronization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4T1E1BipolarErrors 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.20
The total number of bipolar violations detected on the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4T1E1CRCErrors 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.21
The total number of frame level CRC errors detected on the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4T1E1SyncErrors 1.3.6.1.4.1.307.1.1.2.1.4.1.2.1.1.22
The total number of frame synchronization errors detected on the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4CmModem 1.3.6.1.4.1.307.1.1.2.1.4.1.3
OBJECT IDENTIFIER    

lucentPM4ModemTable 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1
A list of modem entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4ModemEntry

lucentPM4ModemEntry 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1
A modem entry containing objects at the session layer.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4ModemEntry  

lucentPM4ModemBoardIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.1
A unique value for each modem interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4ModemUnitType 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.2
Unit type specifies the type of device or interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMUnitType  

lucentPM4ModemIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.3
A unique value for each modem interface. The value of this object can be 1 - 96 for a Quad T1, 1 - 94 for a Tri E1 card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4ModemPortName 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.4
A textual string containing the name of the serial interface (ie. S0, S1, etc).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

lucentPM4ModemStatus 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.5
A current state of the modem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), bound(2), connecting(3), active(4), test(5), down(6), ready(7), halt(8), admin(9)  

lucentPM4ModemProtocol 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.6
The error correcting protocol being used in the modem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), lapm(2), mnp(3), bufferd(4), direct(5), cellular(6)  

lucentPM4ModemCompression 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.7
The compression being used in the modem interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), v42bis(2), mnp5(3), stac(4)  

lucentPM4ModemInSpeed 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.8
An estimate of the modem interface's current inbound bandwidth in bits per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4ModemOutSpeed 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.9
An estimate of the modem interface's current outbound bandwidth in bits per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4ModemInByteCount 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.10
The total number of bytes received on the serial interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4ModemOutByteCount 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.11
The total number of bytes transmitted on the serial interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4ModemRetrains 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.12
The number of retrains attempted by the modem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4ModemRenegotiates 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.13
The number of renegotiates attempted by the modem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4ModemCalls 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.14
The number of times a call received by the modem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4ModemDetects 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.15
The number of analog calls received by the modem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4ModemConnects 1.3.6.1.4.1.307.1.1.2.1.4.1.3.1.1.16
The number of successful calls received by the modem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lucentPM4CmEther 1.3.6.1.4.1.307.1.1.2.1.4.1.4
OBJECT IDENTIFIER    

lucentPM4EtherTable 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1
A list of ethernet interface entries. This object is not accessible
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4EtherEntry

lucentPM4EtherEntry 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1
Ethernet interface entry containing objects at the Session/Physical layers.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4EtherEntry  

lucentPM4EtherBoardIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.1
A unique value for each ethernet board. The manager card has two ethernet interfaces at present. The ethernet interface in slot 4 has a board ID 10 and if there is a manager card in slot 5, the board ID for the interface would be 11.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4EtherIfType 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.2
The interface type which together with the board ID and the interface number will uniquely identify the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMUnitType  

lucentPM4EtherIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.3
A unique value for each ethernet interface. The manager card has two ethernet interfaces at present. ether0(1) represents 10 Base-T interface and ether1(2) specifies the 10/100 Base-T auto-sensing ethernet interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ether0(1), ether1(2), other(3)  

lucentPM4EtherIfIndex 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.4
IfIndex cross reference value for the ethernet interfaces. The manager card has two ethernet interfaces at present. ether0(67436545) represents 10 Base-T interface which corresponds to board 4 and interface 1. The enumerated value ether1(168099841) specifies the 10/100 Base-T auto-sensing ethernet interface which corresponds to board 4 and interface 2. We can add the standby manager card ethernet interfaces when they are available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ether0(67436545), ether1(168099841)  

lucentPM4EtherPortName 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.5
A printable ASCII string specifying the name of the ethernet port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..8)  

lucentPM4EtherMacAddress 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.6
Physical address of the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

lucentPM4EtherIpAddress 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.7
IP address of the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

lucentPM4EtherIpGateway 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.8
IP address of the gateway machine.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

lucentPM4EtherPriNameServer 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.9
IP address of the primary name server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

lucentPM4EtherAltNameServer 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.10
IP address of the alternate name server.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

lucentPM4EtherSubnetMask 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.11
Subnet mask of the interface. Used to partition the network into different branches.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

lucentPM4EtherInFilter 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.12
IP Input packet filter. Used to control the type of IP packets reaching the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..16)  

lucentPM4EtherOutFilter 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.13
IP output packet filter. Used to control the type of packets sent out of the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..16)  

lucentPM4EtherOptRip 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.14
The RIP protocol enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptSlip 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.15
The SLIP protocol enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptEtherDown 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.16
Ethernet interface down enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptBcastHigh 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.17
Use high one(s) broadcast address enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptSnmp 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.18
Default SNMP protocol enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptNoListen 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.19
Do not listen to RIP on the ether interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptDefaultRip 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.20
Default RIP protocol enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptDefaultListen 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.21
Default listen enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptIPFilter 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.22
IP filter enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptDns 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.23
DNS enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptPmeMsg 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.24
PME Msg. enable/disable option. Whatever that means.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptNoClip 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.25
No Clip enable/disable option. Whatever that means.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptEtherIpx 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.26
Ether IPX enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptNetBIOS 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.27
Net BIOS enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptAccounting 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.28
Accounting enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4EtherOptNoPAP 1.3.6.1.4.1.307.1.1.2.1.4.1.4.1.1.29
PAP enable/disable option.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4FaultMgmt 1.3.6.1.4.1.307.1.1.2.1.5
OBJECT IDENTIFIER    

lucentPM4FaultMgmtIsolation 1.3.6.1.4.1.307.1.1.2.1.5.1
OBJECT IDENTIFIER    

lucentPM4FaultMgmtChasTrap 1.3.6.1.4.1.307.1.1.2.1.5.1.1
Chassis Trap table which indicates one of several Traps. The chassis trap table stores the previous history of the traps which can be retrieved by the management stations at a later time. This object is not-accessible and present for MIB clarity.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4FMChasTrapEntry

lucentPM4FMChasTrapEntry 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1
Entry in the chassis Trap table. Each trap is uniquely identified by an index. This object is not accessible and present for MIB clarity.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4FMChasTrapEntry  

lucentPM4FMChasTrapIndex 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.1
Index into the Trap table on the agent. This table stores the previous 500 traps which can be retrieved at any given time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4FMChasTrapBoardID 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.2
Board ID is the board number for which this trap is stored. If the trap is for an auxillary device such as a power supply or fan, this value is set to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4FMChasTrapUnitType 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.3
Uniquely specifies the unit type for this trap. The unit can be a board or any other device in the chassis such as a fan or a power supply.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMUnitType  

lucentPM4FMChasTrapUnitIndex 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.4
Uniquely specifies the unit index. The unit index is same as the ifIndex for T1/E1 interfaces, or the modemIndex for the modems or fan or power supply index for fan or power supplies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4FMChasTrapStatus 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.5
Trap status specifies the associated object in the Trap is online(2), offline(3), maintenance(4) or fault(5).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), online(2), offline(3), maintenance(4), fault(5), notinstalled(6)  

lucentPM4FMChasTrapSeverity 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.6
Trap severity specifies the severity of the Trap for the associated object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMAlarmType  

lucentPM4FMChasTrapTimeStamp 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.7
This object stores the timestamp of this trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

lucentPM4FMChasTrapState 1.3.6.1.4.1.307.1.1.2.1.5.1.1.1.8
This object stores the Trap state of this trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER trapsent(1), ackdue(2), acked(3)  

lucentPM4FMBoardIndex 1.3.6.1.4.1.307.1.1.2.1.5.1.2
Board index uniquely specifies the board in the chassis. This object is set to zero for power supplies, fans and other auxillary devices. This object is not accessible through Get, Get-Next or Set PDUs. It is sent out as part of the Trap.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

lucentPM4FMUnitIndex 1.3.6.1.4.1.307.1.1.2.1.5.1.3
Unit index uniquely specifies the T1/E1 line, or modem or any device (logical/physical) in the chassis. This object is not accessible through Get, Get-Next or Set PDUs. It is sent out as part of the Trap.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

lucentPM4FMUnitType 1.3.6.1.4.1.307.1.1.2.1.5.1.4
Unit type specifies the T1/E1 line, or modem or any device in the chassis. This object is not accessible through Get, Get-Next or Set PDUs. It is sent out as part of the Trap.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PMUnitType  

lucentPM4FMUnitTrapStatus 1.3.6.1.4.1.307.1.1.2.1.5.1.5
Trap status specifies the associated object in the Trap. This object is not accessible other than when produced as the result of a trap.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER other(1), offline(2), online(3), failed(4), restored(5), pwrwarn(6), tempwarn(7), temphot(8), dtrloss(9), carrierloss(10), renegotiation(11), los(12), ais(13), redalarm(14), yellowalarm(15), cv(16), crc(17), bpv(18), fer(19), pll(20), es(21), ses(22), sefs(23), uas(24), dm(25), les(26), css(27), bes(28)  

lucentPM4FMUnitTrapSeverity 1.3.6.1.4.1.307.1.1.2.1.5.1.6
Trap severity specifies the severity of the Trap for the associated object. This object is not accessible except when produced as the result of a trap.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PMAlarmType  

lucentPM4FMTrapConfig 1.3.6.1.4.1.307.1.1.2.1.5.2
OBJECT IDENTIFIER    

lucentPM4FMEqpTrapCfg 1.3.6.1.4.1.307.1.1.2.1.5.2.1
Equipment Trap configuration table configure Traps. The objects in this table are used to enable or disable traps on a per board/interface/device basis. This object is not-accessible and present for MIB clarity.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4FMEqpTrapCfgEntry

lucentPM4FMEqpTrapCfgEntry 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1
Entry in the equipment Trap config table. Each trap is uniquely identified by the board ID, Unit type and unit index. For auxillary devices such as power supplies and fans, the board index will be zero, the unit index identifies the units and the unit type specifies if the unit is a fan, power supplies etc. This object is not accessible and present for MIB clarity.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4FMEqpTrapCfgEntry  

lucentPM4FMEqpBoardIndex 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.1
Board ID for which the Trap configuration need to apply. The board ID is zero if this trap configuration is for an auxillary device such as fans or power supplies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEqpUnitType 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.2
Unit type alongwith the board index and unit index specifies uniquely the device/interface which is being configured.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMUnitType  

lucentPM4FMEqpUnitIndex 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.3
Unit index refers to the interface or sub-device such as a modem, serial port etc. For devices such as power supplies and fans this object is zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEqpTrapId 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.4
Trap ID indicating the trap for which the configuration must apply.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER boardoffline(1), boardonline(2), pwrsupfail(3), pwrsuprestored(4), fanfail(5), fanrestored(6), boardtempwarn(7), boardtempnormal(8), boardtoohot(9), modemfail(10), linedown(11), lineup(12), linethresh(13), boardpwrshutdown(14), radiusauthfail(15)  

lucentPM4FMEqpTrapCtl 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.5
Trap control which configures the trap off(1) or on(2). When the trap is configured as off(1), the trap is not sent out to the management station. When configures as on(2), the trap is sent to all the management stations configured to receive the trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4FMEqpRepTimer 1.3.6.1.4.1.307.1.1.2.1.5.2.1.1.6
If the trap is to be repeated, this object specifies the time in seconds. When this object value is set to 0, it indicates the trap is non-repeat trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

lucentPM4FMT1E1ThreshTrapCfg 1.3.6.1.4.1.307.1.1.2.1.5.2.2
T1/E1 Threshold Trap configuration table to configure the thresholds for various T1/E1 traps. This object is not-accessible and present for MIB clarity.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4FMThreshT1E1TrapCfgEntry

lucentPM4FMT1E1ThreshTrapCfgEntry 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1
Entry in the T1/E1 threshold trap config table. Each trap is uniquely identified by the board index, unit type and unit index which is the T1/E1 interface number. This object is not accessible and present for MIB clarity.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4FMThreshT1E1TrapCfgEntry  

lucentPM4FMT1E1ThreshBoardIndex 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.1
Board ID for which the Trap threshold configuration must apply. It includes boards 1 - 10 and other devices such as power supplies and fans etc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4FMT1E1ThreshUnitType 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.2
Unit type for which the Trap threshold configuration must be applied.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMUnitType  

lucentPM4FMT1E1ThreshESs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.3
The threshold for errored seconds on the interface. A trap is issued when this set limit is exceeded. When this threshold exceeds, the performance of the interface will degrade. A trap is generated to notify the adminstrator to take appropriate action.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshSESs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.4
The threshold for severely errored seconds on the interface. A trap is issued when this limit is exceeded. A severely errored seconds is a second with 320 or more path code violation error events or one or more out of frame defects or detected AIS defect.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshSEFSs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.5
The threshold for severely errored framing seconds. A trap is issued when this threshold is exceeded. A severely errored framing second is a second with one or more frame defects or detected AIS defect.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshUASs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.6
The threshold for unavailable seconds. A trap is issued when this set threshold is exceeded. Unavailable seconds are calculated by counting the number of seconds that the interface is unavailable from the onset of 10 SESs. Once unavailable, the interface becomes available at the onset of 10 contiguous no SESs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshCSSs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.7
The threshold for controlled slip seconds on the interface. A trap is issued when this set threshold is exceeded. A controlled slip second is a one-second interval containing one or more controlled slips.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshPCVs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.8
The threshold for path code violations on the interface. A trap is issued when this set threshold is exceeded. PCV is a frame syncronization bit error in the D4 and E1-noCRC format interfaces or a CRC error in the ESF (extended super frame) and E1-CRC interface formats.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshLESs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.9
The threshold for line errored seconds on the interface. A trap is sent to the manager when this set threshold is exceeded. A line errored second, according to T1M1.3 is a second in which one or more line code violations were detected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshBESs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.10
The threshold for bursty errored seconds on the interface. A trap is sent to the manager when this set threshold is exceeded. A bursty errored second is a second with fewer than 320 and more than 1 path code violations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshDMs 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.11
The threshold for degraded minutes on the interface. A trap is sent to the manager when this set threshold is exceeded. Degraded minutes are determined by collecting all of the available seconds, after removing any severely errored seconds. The resulting seconds is grouped into 60 second intervals and if the cumulative errors during the seconds present in the group exceeds 1E-6.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Gauge  

lucentPM4FMT1E1ThreshRepTimer 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.12
If the trap is to be repeated, this object specifies the time in seconds. When this object value is set to 0, it indicates the trap is non-repeat trap.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

lucentPM4FMT1E1ThreshTrapAck 1.3.6.1.4.1.307.1.1.2.1.5.2.2.1.13
If set to ack(3), clears the trap condition. If the value is set to noack(2), leaves the trap condition unchanged.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), noack(2), ack(3)  

lucentPM4FMEnvTrapCfg 1.3.6.1.4.1.307.1.1.2.1.5.2.3
Environment Trap configuration table. This table enables configuration of voltage, power levels and temperature ranges for different units in the chassis. This object is not-accessible and present for MIB clarity.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4FMEnvTrapCfgEntry

lucentPM4FMEnvTrapCfgEntry 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1
Entry in the environment trap config table. Each trap is uniquely identified by the board index, unit type and unit index. This object is not accessible and present for MIB clarity.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4FMEnvTrapCfgEntry  

lucentPM4FMEnvBoardID 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.1
Board ID specifies the board identifier for this trap. If the trap configuration is for an auxillary device such as a power supply or fan, this object will be set to zero. The unit type and the unit index will uniquely identify the auxillary devices.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEnvUnitType 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.2
Unit for which the Trap configuration must to apply.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMUnitType  

lucentPM4FMEnvUnitIndex 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.3
Unit index specifies the interface or sub-unit for this trap (modem or T1/E1 interface etc.). The unit type and the unit index will uniquely identify the auxillary devices.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEnvOptUnitTemp 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.4
The optimum temperature for this unit. A trap is generated when the temperature deviates from the specified range. The temperature is specified as an integer in degrees farenheit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEnvUnitTempRange 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.5
The temperature range above which a trap is generated. The temperature must be specified as an integer in degree Farenhiet (for example +/- 5 degree Far.).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEnvOptUnitPwrLvl 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.6
The optimal power level that is appropriate for this unit. A trap is generated when the power level fluctuates outside the limits set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEnvUnitPwrRange 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.7
The power range specified in volts. A trap is generated when the power level fluctuates outside the Opt Pwr +/- Range set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

lucentPM4FMEnvTrapCtl 1.3.6.1.4.1.307.1.1.2.1.5.2.3.1.8
The trap control used to turn the environment traps on or off for the specified unit(s).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

lucentPM4PerfMgmt 1.3.6.1.4.1.307.1.1.2.1.6
OBJECT IDENTIFIER    

lucentPM4T1E1PerfMgmt 1.3.6.1.4.1.307.1.1.2.1.6.1
OBJECT IDENTIFIER    

lucentPM4T1E1PMCur 1.3.6.1.4.1.307.1.1.2.1.6.1.1
Performance management table representing the performance statistics of T1/E1 interfaces in the box. This table represents the current 15 mins statistics. This object is not accessible and present for clarity purpose. This table is part of RFC 1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4T1E1PMCurEntry

lucentPM4T1E1PMCurEntry 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1
Performance management table entries for all the T1/E1 interfaces in the box. This table represents the current 15 mins statistics. This object is not accessible and present for clarity purpose.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4T1E1PMCurEntry  

lucentPM4T1E1PMCurBoard 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.1
Board number of the interface. The global interface number is computed by using the Most Significant byte of the ifIndex and the Least Significant 2 bytes represents the interface index. Byte 3 will represent the unit type which would be a T1 or E1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMCurUnitType 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.2
Unit type indicates the type of interface as T1/E1 or T3/E3 in future. This is part of the interface table ifIndex which is constructed with boardID, unit type and unit index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMUnitType  

lucentPM4T1E1PMCurLineNum 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.3
Line number uniquely identifies the T1/E1 interface on a given board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMCurIfIndex 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.4
Interface table ifIndex cross reference. The global interface number is computed by using the Most Significant byte as the board ID and the Least Significant 2 bytes represents the interface index. The third byte represents the unit type which will be a T1 or E1. Thus board 0 interface 3 is represented as 0x00050003. The global interface number corresponds to the IfIndex in MIB II.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMCurESs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.5
The number of errored seconds, encountered by the line in the current 15 mins interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurSESs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.6
The number of Severely Errored Seconds encountered by the line in the current 15 mins interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurSEFSs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.7
The number of Severely Errored Framing Seconds encountered by the line in the current 15 mins interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurUASs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.8
The number of Unavailable Seconds encountered by the line in the current 15 mins interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurCSSs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.9
The number of Controlled Slip Seconds encountered by the line in the current 15 mins interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurPCVs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.10
The number of Path Coding Violations encountered by the line in the current 15 mins interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurLESs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.11
The number of Line Errored Seconds encountered by the line in the current 15 mins interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurBESs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.12
The number of Bursty Errored Seconds encountered by the line in the current 15 mins interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurDMs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.13
The number of Degraded Minutes encountered by the line in the current 15 mins interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMCurLCVs 1.3.6.1.4.1.307.1.1.2.1.6.1.1.1.14
The number of Line Code Violations encountered by the line in the current 15 mins interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMInt 1.3.6.1.4.1.307.1.1.2.1.6.2
Performance management table representing the performance statistics of T1/E1 interfaces in the box. This table represents the 24 hr statistics divided into 96 15 mins intervals. This object is not accessible and present for clarity purpose. This table is part of RFC 1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4T1E1PMIntEntry

lucentPM4T1E1PMIntEntry 1.3.6.1.4.1.307.1.1.2.1.6.2.1
Performance management table entries for all the T1/E1 interfaces in the box. This table represents the 24 hr statistics divided into 96 15 mins intervals. This object is not accessible and present for clarity purpose.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4T1E1PMIntEntry  

lucentPM4T1E1PMIntBoard 1.3.6.1.4.1.307.1.1.2.1.6.2.1.1
Board number of the interface. The global interface number is computed by using the Most Significant nibble of the ifIndex and the Least Significant nibble represents the interface index. Thus board 0 interface 3 is represented as 0x03 or 03 decimal and board 10 interface 3 is represented as 0xa3 or 163 decimal. In an integer, of 4 bytes wide, the 3 MSBytes will all be zeros. The global interface number corresponds to the IfIndex of MIB II.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMIntUnitType 1.3.6.1.4.1.307.1.1.2.1.6.2.1.2
Unit type indicates the type of physical or logical device. The unit type for this table is either T1 or E1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMUnitType  

lucentPM4T1E1PMIntLineNum 1.3.6.1.4.1.307.1.1.2.1.6.2.1.3
Line number uniquely identifies the T1/E1 interface for this board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMIntInterval 1.3.6.1.4.1.307.1.1.2.1.6.2.1.4
Interval number for a given board. The 24 hr period is divided into 96 15 min intervals, where 1 is the most recent and 96 is the least recent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

lucentPM4T1E1PMIntIfIndex 1.3.6.1.4.1.307.1.1.2.1.6.2.1.5
Interface table ifIndex cross reference. The global interface number is computed by using the Most Significant byte as the board ID and the Least Significant 2 bytes represents the interface index. The third byte represents the unit type which will be a T1 or E1. Thus board 0 interface 3 is represented as 0x00050003. The global interface number corresponds to the IfIndex in MIB II.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMIntESs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.6
The number of errored seconds, encountered by the line in the last 24 hrs divided into 96 15 mins intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntSESs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.7
The number of Severely Errored Seconds encountered by the line for one of the 96 15 mins intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntSEFSs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.8
The number of Severely Errored Framing Seconds encountered by the line for one of the 96 15 mins intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntUASs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.9
The number of Unavailable Seconds encountered by the line for one of the 96 15 mins intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntCSSs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.10
The number of Controlled Slip Seconds encountered by the line for one of the 96 15 mins intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntPCVs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.11
The number of Path Coding Violations encountered by the line for one of the 96 15 mins intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntLESs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.12
The number of Line Errored Seconds encountered by the line for one of the 96 15 mins intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntBESs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.13
The number of Bursty Errored Seconds encountered by the line for one of the 96 15 mins intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntDMs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.14
The number of Degraded Minutes encountered by the line for one of the 96 15 mins intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMIntLCVs 1.3.6.1.4.1.307.1.1.2.1.6.2.1.15
The number of Line Code Violations encountered by the line for one of the 96 15 mins intervals.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotal 1.3.6.1.4.1.307.1.1.2.1.6.3
Performance management table representing the performance statistics of T1/E1 interfaces in the box. This table represents the 24 hr statistics divided into 96 15 mins intervals. This object is not accessible and present for clarity purpose. This table is part of RFC 1406.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4T1E1PMTotalEntry

lucentPM4T1E1PMTotalEntry 1.3.6.1.4.1.307.1.1.2.1.6.3.1
Performance management table entries for all the T1/E1 interfaces in the box. This table represents the 24 hr statistics divided into 96 15 mins intervals. This object is not accessible and present for clarity purpose.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4T1E1PMIntEntry  

lucentPM4T1E1PMTotalBoard 1.3.6.1.4.1.307.1.1.2.1.6.3.1.1
Board number of the interface. The global interface number is computed by using the Most Significant nibble of the ifIndex and the Least Significant nibble represents the interface index. Thus board 0 interface 3 is represented as 0x03 or 03 decimal and board 10 interface 3 is represented as 0xa3 or 163 decimal. In an integer, of 4 bytes wide, the 3 MSBytes will all be zeros. The global interface number corresponds to the IfIndex of MIB II. This table stores the cumulative values for the past 24 hr period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMTotalUnitType 1.3.6.1.4.1.307.1.1.2.1.6.3.1.2
Unit type indicates the type of physical or logical device. The unit type for this table is either T1 or E1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PMUnitType  

lucentPM4T1E1PMTotalLineNum 1.3.6.1.4.1.307.1.1.2.1.6.3.1.3
Interface number for a given board. The global interface number is computed by using the Most Significant nibble of the ifIndex and the Least Significant nibble represents the interface index. Thus board 0 interface 3 is represented as 0x03 or 03 decimal and board 10 interface 3 is represented as 0xa3 or 163 decimal. In an integer, of 4 bytes wide, the 3 MSBytes will all be zeros. The global interface number corresponds to the IfIndex in MIB II.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMTotalIfIndex 1.3.6.1.4.1.307.1.1.2.1.6.3.1.4
IfIndex cross reference value. This value is obtained from the Board/board number and interface number by combining them into the LSByte. The upper nibble represents the board and the lower nibble represents the line number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4T1E1PMTotalESs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.5
The cumulative value of errored seconds, encountered by the line in the last 24 hrs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalSESs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.6
The cumulative value Severely Errored Seconds encountered by the line for the 24 hr period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalSEFSs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.7
The cumulative value of Severely Errored Framing Seconds encountered by the line for the 24 hr period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalUASs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.8
The cumulative value of Unavailable Seconds encountered by the line for the 24 hr period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalCSSs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.9
The cumulative value of Controlled Slip Seconds encountered by the line for the 24 hr period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalPCVs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.10
The cumulative value of Path Coding Violations encountered by the line for the 24 hr period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalLESs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.11
The cumulative value of Line Errored Seconds encountered by the line for the 24 hr period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalBESs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.12
The cumulative value of Bursty Errored Seconds encountered by the line for the 24 hr period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalDMs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.13
The cumulative value of Degraded Minutes encountered by the line for the 24 hr period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4T1E1PMTotalLCVs 1.3.6.1.4.1.307.1.1.2.1.6.3.1.14
The cumulative value of Line Code Violations encountered by the line for the 24 hr period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

lucentPM4SecurityMgmt 1.3.6.1.4.1.307.1.1.2.1.7
OBJECT IDENTIFIER    

lucentPM4AcctMgmt 1.3.6.1.4.1.307.1.1.2.1.8
OBJECT IDENTIFIER    

lucentPM4AcctMgmtComm 1.3.6.1.4.1.307.1.1.2.1.8.1
OBJECT IDENTIFIER    

lucentPM4SnmpCommTable 1.3.6.1.4.1.307.1.1.2.1.8.1.1
The SNMP Community Table. This table contains entries to restrict the SNMP get and set operations.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4SnmpCommEntry

lucentPM4SnmpCommEntry 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1
The entries in the community table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4SnmpCommEntry  

lucentPM4SnmpCommIndex 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.1
The index of the command in the command table. A MAX of 10 network management stations must be specified along with their community names.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10  

lucentPM4SnmpCommName 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.2
The name of the SNMP Community for SNMP readers and writers. The size of the string is limited to 32 characters. All characters in the string must be printable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(1..32)  

lucentPM4SnmpCommIpAddr 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.3
The IP Address of the remote community.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

lucentPM4SnmpCommReadAccess 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.4
Read access enable or disable for this community. When enabled, it allows read-only variable access using this community string by the SNMP client.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), ensable(2)  

lucentPM4SnmpCommWriteAccess 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.5
Write access enable or disable for this community. When enabled, the agent allows write access to the parameters on the agent by the SNMP clients.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), ensable(2)  

lucentPM4SnmpCommTraps 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.6
Traps receiving capability enable or disable for this community. When enabled, the SNMP agent forwards the traps generated in the box to this SNMP client.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), ensable(2)  

lucentPM4SnmpCommStatus 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.7
The status of the entry for this community. If the status is set to normal, it allows requests from this SNMP client else it discards the requests from this client.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), delete(2)  

lucentPM4SnmpCommLastError 1.3.6.1.4.1.307.1.1.2.1.8.1.1.1.8
If there is an error on a request, this variable may contain a message indicating the error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..511)  

lucentPM4AcctMgmtCallEvent 1.3.6.1.4.1.307.1.1.2.1.8.2
OBJECT IDENTIFIER    

lucentPM4AMCallEventTable 1.3.6.1.4.1.307.1.1.2.1.8.2.1
Call accounting table containing a list of call events, which may be used for billing purposes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LucentPM4AMCallEventEntry

lucentPM4AMCallEventEntry 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1
The entries in the accounting/billing table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LucentPM4AMCallEventEntry  

lucentPM4AMCEIndex 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.1
Call event index used as an index into the call event table. The table stores call events which may be used for billing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCETimeStamp 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.2
Time stamp for this event in seconds since the last reboot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCEType 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.3
Specifies the type of event associated with this entry in the call event table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER calloriginated(1), callanswered(2), callcleared(3), servicechanged(4), namechanged(5), baudratechanged(6)  

lucentPM4AMCESvcType 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.4
The type of service provided to the user. This field is meaningful if the event type is servicechanged(4), or namechanged(5) events. In all other cases, this object must return none(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ppp(2), slip(3), mpp(4), x25(5), combinet(6), frameRelay(7), euraw(8), euui(9), telnet(10), telnetBinary(11), rawTcp(12), terminalServer(13), mp(14), virtualConnect(15), x25DChannel(16)  

lucentPM4AMCEUName 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.5
User name of the dialed in user. This object returns the valid user name when the event type is servicechanged(4) or namechanged(5). In all other cases, it returns a NULL.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

lucentPM4AMCEModemBoard 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.6
Board ID of the modem which handled this call. This value can be used to diagnose modem related problems (dropping the call, retraining too frequently etc.).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCEModemID 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.7
Identifies the specific modem on a board which handled this call. Can be used to diagnose modem related problems.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCEModemPort 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.8
A textual string containing the name of the serial interface (ie. S0, S1, etc).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

lucentPM4AMCEDataRate 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.9
Specifies the speed of this connection. Speed is specified as baud rate for modem calls and receive data rate for ISDN calls. This object returns a 0 for call answered and call cleared events.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCECallingPartyID 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.10
Calling party ID. This object is valid only for call answered, call originated, and call cleared events. For all invalid event types, this object is set to NULL.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

lucentPM4AMCECalledPartyID 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.11
Called party ID. This object is valid only for call answered, call originated, and call cleared events. For all invalid event types, this object is set to NULL.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

lucentPM4AMCEInOctets 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.12
Total octets received during this call. This object is cleared at the end of each call.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCEOutOctets 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.13
Total octets sent out during this call. This object is cleared at the end of each call.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCECallCharge 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.14
Call charge for this call. This object is valid only when the event is call cleared. For all other events this object is set to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lucentPM4AMCEDisconnReason 1.3.6.1.4.1.307.1.1.2.1.8.2.1.1.15
Reason for the disconnect.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), unknown(2), disconnected(3), clidAuthFailed(4), clidAuthServTimeout(5), clidAuthRequestCallback(6), preT310Timeout(7), noModemAvailable(9), noModemNoCarrier(10), noModemLossCarrier(11), noModemResultCodes(12), noModemOpenFailed(13), noModemOpenFailedDiag(14), tsUserExit(20), tsIdleTimeout(21), tsExitTelnet(22), tsNoIPAddr(23), tsExitTcp(24), tsPassWordFail(25), tsRawTCPDisable(26), tsControlC(27), tsDestroyed(28), tsClosedVirtualConnect(29), tsVirtualConnectDestroyed(30), tsExitRlogin(31), tsRloginBadOption(32), tsErrorResource(33), mpNullMessageTimeout(35), pppLcpTimeout(40), pppLcpNegotiateFail(41), pppPAPAuthFail(42), pppCHAPAuthFail(43), pppRemoteAuthFail(44), pppRcvTerminate(45), pppCloseEvent(46), pppCloseNoNcpsOpened(47), pppCloseUnknownMpBundle(48), pppCloseMpAddChanFail(49), tsExitErrTooMany(50), tsExitErrResource(51), tsExitErrInvalidIP(52), tsExitErrHostName(53), tsExitErrBadPort(54), tsExitErrHostReset(60), tsExitErrConnRefused(61), tsExitErrTimedOut(62), tsExitErrClosed(63), tsExitErrNetUnreach(64), tsExitErrHostUnreach(65), tsExitErrNetAdminUnreach(66), tsExitErrHostAdminUnreach(67), tsExitErrPortUnreach(68), sessTimeOut(100), sessFailSecurity(101), sessCallback(102), invalidProtocol(120), requestByRadiusClient(150), localAdmin(151), localSnmp(152), v110Timeout(160), pppAuthTimeout(170), userCallClearRequest(180), remoteEndHungUp(185), resourceQuiesced(190), maxCallDurationReached(195), lowMemory(201), boardDied(210)  

lucentPM4BoardOfflineTrap 1
Board down trap. The variable bindings in the Trap packet provide information about the chassis name, board number and the trap status. This Trap must be cleared manually.
TRAP-TYPE    

lucentPM4BoardOnlineTrap 2
Board up trap. The variable bindings in the Trap packet provide information about the chassis name, board number and the trap status. This Trap must be cleared manually.
TRAP-TYPE    

lucentPM4PwrSupFailTrap 3
Power supply failed trap. The variable bindings in the Trap packet provide information about the chassis name, power supply unit and the trap status. This Trap must be cleared manually.
TRAP-TYPE    

lucentPM4PwrSupWarnTrap 4
Power supply warning trap. The variable bindings in the Trap packet provide information about the chassis name, power supply unit and the trap status. This Trap is issued when the power supply fluctuates between a set threshold. This Trap must be cleared manually.
TRAP-TYPE    

lucentPM4PwrSupRestoredTrap 5
Power supply restored trap. The variable bindings in the Trap packet provide information about the chassis name, power supply unit and the trap status. This Trap is issued when a failed power supply is restored. This must be cleared manually.
TRAP-TYPE    

lucentPM4FanFailTrap 6
Fan failure trap. The variable bindings in the Trap packet provide information about the chassis name, fan number and the trap status. This Trap must be cleared manually.
TRAP-TYPE    

lucentPM4FanRestoredTrap 7
Fan restored trap. The variable bindings in the Trap packet provide information about the chassis name, fan number and the trap status. This Trap is issued when the failed fan is restored. This trap must be cleared manually.
TRAP-TYPE    

lucentPM4BoardTempWarnTrap 8
Board temperature warning trap. The variable bindings in the Trap packet provide information about the chassis name, unit and the trap status. This Trap is issued when the board temperature exceeds a set threshold value. This trap must be cleared manually.
TRAP-TYPE    

lucentPM4BoardTempNormalTrap 9
Board temperature normal trap. The variable bindings in the Trap packet provide information about the chassis name, unit and the trap status. This Trap is issued when the board temperature returns to normal. This trap must be cleared manually.
TRAP-TYPE    

lucentPM4BoardTooHotTrap 10
Board trap. The variable bindings in the Trap packet provide information about the chassis name, board number and the trap status. This Trap must be cleared manually.
TRAP-TYPE    

lucentPM4ModemFailTrap 11
Modem failure trap. The variable bindings in the Trap packet provide information about the chassis name, modem number and the trap status. This Trap must be cleared manually.
TRAP-TYPE    

lucentPM4T1E1LineDownTrap 12
T1/E1 Line trap. The variable bindings in the Trap packet provide all the information for the clients to display the Board ID, Line ID and the status of the line. This Trap could be generated when the line comes up or goes down once. It must be cleared manually.
TRAP-TYPE    

lucentPM4T1E1LineUpTrap 13
T1/E1 Line trap. The variable bindings in the Trap packet provide all the information for the clients to display the Board ID, Line ID and the status of the line. This Trap could be generated when the line comes up or goes down once. It must be cleared manually.
TRAP-TYPE    

lucentPM4T1E1LineThreshTrap 14
T1/E1 Line trap. The variable bindings in the Trap packet provide all the information for the clients to display the Board ID, Line ID and the trap type. This Trap could be generated when the thresholds for the various performance statistics (ES, SES etc.) exceed. It must be cleared manually.
TRAP-TYPE    

lucentPM4BoardPwrOffTrap 15
This trap is issued when the power supply to the board is not enough. The variable bindings in the Trap packet provide information about the chassis name, board/board number and the trap status. This Trap must be cleared manually.
TRAP-TYPE    

lucentPM4RadiusAuthFailTrap 16
This trap is issued when the Radius authentication fails. This Trap must be cleared manually. The trap provides information about the board and the modem number.
TRAP-TYPE