MBG-SNMP-FDMXPT-MIB
File:
MBG-SNMP-FDMXPT-MIB.mib (8303 bytes)
Imported modules
Imported symbols
Defined Values
mbgFDM |
1.3.6.1.4.1.5597.15 |
Top-level infrastructure of the MBG-SNMP project enterprise MIB tree |
MODULE-IDENTITY |
|
|
|
mbgFDMData |
1.3.6.1.4.1.5597.15.2 |
OBJECT IDENTIFIER |
|
|
|
mbgFDMModeVal |
1.3.6.1.4.1.5597.15.2.2 |
current Mode of FDM as value |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
mbgFDMFrequency |
1.3.6.1.4.1.5597.15.2.3 |
current powerline frequency in Hz as measured by FDM |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
mbgFDMFrequencyVal |
1.3.6.1.4.1.5597.15.2.4 |
current powerline frequency in Hz*1000 as value |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
mbgFDMPLTime |
1.3.6.1.4.1.5597.15.2.6 |
current powerline time of FDM |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
mbgFDMFreqDevVal |
1.3.6.1.4.1.5597.15.2.8 |
current frequency deviation in Hz*1000 as value |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
mbgFDMTimeDevVal |
1.3.6.1.4.1.5597.15.2.10 |
current time deviation in ms |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
mbgFDMTrapInternalError |
1.3.6.1.4.1.5597.15.3.1 |
trap to be sent when an internal error occurs (see error bits) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mbgFDMTrapNoTimeString |
1.3.6.1.4.1.5597.15.3.2 |
trap to be sent when no time string can be read from reference clock |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mbgFDMTrapNo10Mhz |
1.3.6.1.4.1.5597.15.3.3 |
trap to be sent when the reference frequency is not available |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mbgFDMTrapNoPPS |
1.3.6.1.4.1.5597.15.3.4 |
trap to be sent when the reference Pulse Per Second is not available |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mbgFDMTrapNoPowerline |
1.3.6.1.4.1.5597.15.3.5 |
trap to be sent when powerline frequency could not be detected |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mbgFDMTrapTimeDeviationOverflow |
1.3.6.1.4.1.5597.15.3.6 |
trap to be sent when a time deviation overflow happens |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mbgFDMTrapA1Overflow |
1.3.6.1.4.1.5597.15.3.7 |
trap to be sent when Analog1 overflows |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mbgFDMTrapA2Overflow |
1.3.6.1.4.1.5597.15.3.8 |
trap to be sent when Analog2 overflows |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mbgFDMTrapFreqLimitExceeded |
1.3.6.1.4.1.5597.15.3.9 |
trap to be sent when the current frequency exceeds the valid frequency range |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mbgFDMXPTReboot |
1.3.6.1.4.1.5597.15.3.10 |
trap to be sent when the FDMXPT module starts up |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mbgFDMNormalOperation |
1.3.6.1.4.1.5597.15.3.99 |
trap to be sent when the FDM status is OK (Normal Operation) |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
mbgFDMCompliance |
1.3.6.1.4.1.5597.15.90.1.1 |
The compliance statement for SNMP entities which implement version 2
of the XPT MIB |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
mbgFDMObjectsGroup |
1.3.6.1.4.1.5597.15.90.2.1 |
The collection of objects for the MBG FDMXPT MIB |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
mbgFDMTrapsGroup |
1.3.6.1.4.1.5597.15.90.2.2 |
The collection of traps for the MBG FDMXPT MIB |
Status: current |
Access: read-only |
NOTIFICATION-GROUP |
|
|
|