METRO1500-MIB

File: METRO1500-MIB.mib (73116 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1213-MIB

Imported symbols

OBJECT-TYPE TRAP-TYPE DisplayString

Defined Types

Metro1500MainTrapsinkEntry  
SEQUENCE    
  metro1500MainTrapsinkNumber INTEGER
  metro1500MainTrapsinkAddress DisplayString
  metro1500MainTrapsinkCommunity DisplayString
  metro1500MainTrapsinkPriority INTEGER

Metro1500MainLogfileEntry  
SEQUENCE    
  metro1500MainLogfileNumber INTEGER
  metro1500MainLogfileName DisplayString
  metro1500MainLogfileSize INTEGER
  metro1500MainLogfilePriority INTEGER

Metro1500SlotEntry  
SEQUENCE    
  metro1500SlotNumber INTEGER
  metro1500Type DisplayString
  metro1500SlotTypeNumber INTEGER
  metro1500SerialNumber DisplayString
  metro1500HardwareVersion DisplayString
  metro1500SoftwareVersion DisplayString
  metro1500Temperature INTEGER
  metro1500BoardVoltage INTEGER
  metro1500DetailInfo OBJECT IDENTIFIER
  metro1500EPLDVersion INTEGER

Metro1500PSEntry  
SEQUENCE    
  metro1500PSNumber INTEGER
  metro1500PSOn INTEGER

Metro1500FanEntry  
SEQUENCE    
  metro1500FanNumber INTEGER
  metro1500FanOn INTEGER

Metro1500ConverterEntry  
SEQUENCE    
  metro1500ConverterNumber INTEGER
  metro1500RxLoc INTEGER
  metro1500TxLoc INTEGER
  metro1500TxLocC INTEGER
  metro1500TxLocTemp INTEGER
  metro1500RxRem INTEGER
  metro1500TxRem INTEGER
  metro1500TxRemC INTEGER
  metro1500TxRemTemp INTEGER
  metro1500RxRem2 INTEGER
  metro1500ClockState INTEGER
  metro1500ClockFreq INTEGER
  metro1500LocLoop INTEGER
  metro1500RemLoop INTEGER
  metro1500ClockType INTEGER

Metro1500SwitchEntry  
SEQUENCE    
  metro1500SwitchNumber INTEGER
  metro1500SwitchLine INTEGER
  metro1500SwitchMode INTEGER
  metro1500SwitchLaserOn INTEGER
  metro1500SwitchLineAavail INTEGER
  metro1500SwitchLineBavail INTEGER

Metro1500EthernetHubEntry  
SEQUENCE    
  metro1500EthernetHubNumber INTEGER
  metro1500EthernetHubPortEnable1 INTEGER
  metro1500EthernetHubPortPartitionStatus1 INTEGER
  metro1500EthernetHubPortLinkStatus1 INTEGER
  metro1500EthernetHubPortPolarity1 INTEGER
  metro1500EthernetHubPortEnable2 INTEGER
  metro1500EthernetHubPortPartitionStatus2 INTEGER
  metro1500EthernetHubPortLinkStatus2 INTEGER
  metro1500EthernetHubPortPolarity2 INTEGER
  metro1500EthernetHubPortEnable3 INTEGER
  metro1500EthernetHubPortPartitionStatus3 INTEGER
  metro1500EthernetHubPortLinkStatus3 INTEGER
  metro1500EthernetHubPortPolarity3 INTEGER
  metro1500EthernetHubPortEnable4 INTEGER
  metro1500EthernetHubPortPartitionStatus4 INTEGER
  metro1500EthernetHubPortLinkStatus4 INTEGER
  metro1500EthernetHubPortPolarity4 INTEGER
  metro1500EthernetHubPortEnable5 INTEGER
  metro1500EthernetHubPortPartitionStatus5 INTEGER
  metro1500EthernetHubPortLinkStatus5 INTEGER
  metro1500EthernetHubPortPolarity5 INTEGER

Metro1500TDMEntry  
SEQUENCE    
  metro1500TDMNumber INTEGER
  metro1500TDMRxRem INTEGER
  metro1500TDMRxSync INTEGER
  metro1500TDMTxRem INTEGER
  metro1500TDMTxRemC INTEGER
  metro1500TDMTxRemTemp INTEGER
  metro1500TDMLocLoop INTEGER
  metro1500TDMLocModuleInst1 INTEGER
  metro1500TDMLocModuleEnable1 INTEGER
  metro1500TDMLocModuleRx1 INTEGER
  metro1500TDMLocModuleTx1 INTEGER
  metro1500TDMLocModuleRemoteData1 INTEGER
  metro1500TDMLocModuleClockFrequency1 INTEGER
  metro1500TDMLocModuleClockError1 INTEGER
  metro1500TDMLocModuleInst2 INTEGER
  metro1500TDMLocModuleEnable2 INTEGER
  metro1500TDMLocModuleRx2 INTEGER
  metro1500TDMLocModuleTx2 INTEGER
  metro1500TDMLocModuleRemoteData2 INTEGER
  metro1500TDMLocModuleClockFrequency2 INTEGER
  metro1500TDMLocModuleClockError2 INTEGER
  metro1500TDMLocModuleInst3 INTEGER
  metro1500TDMLocModuleEnable3 INTEGER
  metro1500TDMLocModuleRx3 INTEGER
  metro1500TDMLocModuleTx3 INTEGER
  metro1500TDMLocModuleRemoteData3 INTEGER
  metro1500TDMLocModuleClockFrequency3 INTEGER
  metro1500TDMLocModuleClockError3 INTEGER
  metro1500TDMLocModuleInst4 INTEGER
  metro1500TDMLocModuleEnable4 INTEGER
  metro1500TDMLocModuleRx4 INTEGER
  metro1500TDMLocModuleTx4 INTEGER
  metro1500TDMLocModuleRemoteData4 INTEGER
  metro1500TDMLocModuleClockFrequency4 INTEGER
  metro1500TDMLocModuleClockError4 INTEGER

Defined Values

org 1.3
OBJECT IDENTIFIER    

dod 1.3.6
OBJECT IDENTIFIER    

internet 1.3.6.1
OBJECT IDENTIFIER    

private 1.3.6.1.4
OBJECT IDENTIFIER    

enterprises 1.3.6.1.4.1
OBJECT IDENTIFIER    

adva 1.3.6.1.4.1.2544
OBJECT IDENTIFIER    

advaProducts 1.3.6.1.4.1.2544.1
OBJECT IDENTIFIER    

metro1500 1.3.6.1.4.1.2544.1.3
OBJECT IDENTIFIER    

metro1500Main 1.3.6.1.4.1.2544.1.3.1
OBJECT IDENTIFIER    

metro1500Housing 1.3.6.1.4.1.2544.1.3.1.1
OBJECT IDENTIFIER    

metro1500Manufacturer 1.3.6.1.4.1.2544.1.3.1.1.1
Manufacturer of the METRO1500 System
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500MainType 1.3.6.1.4.1.2544.1.3.1.1.2
Type of the METRO1500 System
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500MainSerialNumber 1.3.6.1.4.1.2544.1.3.1.1.3
Serial Number of the METRO1500 System
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500MainHardwareVersion 1.3.6.1.4.1.2544.1.3.1.1.4
Hardware Version of the METRO1500 System
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500MainSoftwareVersion 1.3.6.1.4.1.2544.1.3.1.1.5
Software Version of the METRO1500 System (Device Master).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500MainBusMessages 1.3.6.1.4.1.2544.1.3.1.1.6
Number of received internal Messages. This Number gives Information on the internal Activity of the METRO1500 System. This should be a large integer Number except when the System has just started. The Value is updated every five Seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

metro1500MainBusErrors 1.3.6.1.4.1.2544.1.3.1.1.7
Number of dropped received internal Messages. This value should be 0 or a very small Integer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

metro1500MainLastEvent 1.3.6.1.4.1.2544.1.3.1.1.8
Since SNMP Traps are not reliable, this Number can be polled periodically. The Value is set to a nonzero Integer when an Event occurs and cleared ten Minutes after the last Event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

metro1500MainMotd 1.3.6.1.4.1.2544.1.3.1.1.9
Message Of The Day is the greeting when login via telnet. It shows the actual Kernel Version and the Software Update State. With the MOTD you get Information on the actual installed Software Packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500MainTrapsinkTable 1.3.6.1.4.1.2544.1.3.1.1.10
Table of Trapsinks
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Metro1500MainTrapsinkEntry

metro1500MainTrapsinkEntry 1.3.6.1.4.1.2544.1.3.1.1.10.1
Entries in the Trapsink Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Metro1500MainTrapsinkEntry  

metro1500MainTrapsinkNumber 1.3.6.1.4.1.2544.1.3.1.1.10.1.1
Number of Trapsink
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10  

metro1500MainTrapsinkAddress 1.3.6.1.4.1.2544.1.3.1.1.10.1.2
IP Address of the Management System which should receive SNMP Traps. The Logfiles are also shown in this Table
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500MainTrapsinkCommunity 1.3.6.1.4.1.2544.1.3.1.1.10.1.3
Community String which is sent with a SNMP Trap to the Management Station
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500MainTrapsinkPriority 1.3.6.1.4.1.2544.1.3.1.1.10.1.4
Priority of the Trapsink (lower level gets less Traps)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..20  

metro1500MainLogfileTable 1.3.6.1.4.1.2544.1.3.1.1.11
Table of Log Files
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Metro1500MainLogfileEntry

metro1500MainLogfileEntry 1.3.6.1.4.1.2544.1.3.1.1.11.1
Entries in the Logfile Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Metro1500MainLogfileEntry  

metro1500MainLogfileNumber 1.3.6.1.4.1.2544.1.3.1.1.11.1.1
Number of Logfile
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

metro1500MainLogfileName 1.3.6.1.4.1.2544.1.3.1.1.11.1.2
Name of Logfile
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500MainLogfileSize 1.3.6.1.4.1.2544.1.3.1.1.11.1.3
Size of Logfile
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

metro1500MainLogfilePriority 1.3.6.1.4.1.2544.1.3.1.1.11.1.4
Priority of Logfile
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..20  

metro1500SlotTable 1.3.6.1.4.1.2544.1.3.1.2
Table of installed METRO1500 Components. Since METRO1500 can handle many different Components, in this Section only the common Information is displayed. Component specific Information is stored in different Subtrees.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Metro1500SlotEntry

metro1500SlotEntry 1.3.6.1.4.1.2544.1.3.1.2.1
Installed METRO1500 Components
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Metro1500SlotEntry  

metro1500SlotNumber 1.3.6.1.4.1.2544.1.3.1.2.1.1
Slot Number of installed Component. The Device Master has always Slot Number 0 and is shown in the Main section.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..79  

metro1500Type 1.3.6.1.4.1.2544.1.3.1.2.1.2
Type of installed Component
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500SlotTypeNumber 1.3.6.1.4.1.2544.1.3.1.2.1.3
Integer Number between 0 and 255 unique for a specific type of installed Component. This Number can be used for management Systems to handle automatically the different Options of installed Components.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER metro1500Converter(1), metro1000Converter(2), metro1000EthernetConverter(3), metro1500-2-5GbConverter(5), metro1500-TRL-Converter(7), metro1500-4PortTDMCard(10), nemi(32), demi(33), metro1500-EthernetHubCard(39), switch(64), other(255)  

metro1500SerialNumber 1.3.6.1.4.1.2544.1.3.1.2.1.4
Serial Number of installed Component
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500HardwareVersion 1.3.6.1.4.1.2544.1.3.1.2.1.5
Hardware Version of installed Component
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500SoftwareVersion 1.3.6.1.4.1.2544.1.3.1.2.1.6
SoftwareVersion of installed Component
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

metro1500Temperature 1.3.6.1.4.1.2544.1.3.1.2.1.7
Temperature of installed Component in Celsius
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

metro1500BoardVoltage 1.3.6.1.4.1.2544.1.3.1.2.1.8
Voltage measured directly on the board in mV
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

metro1500DetailInfo 1.3.6.1.4.1.2544.1.3.1.2.1.9
A Reference to the MIB Definition where the special Options of the Component are described with more Details
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

metro1500EPLDVersion 1.3.6.1.4.1.2544.1.3.1.2.1.10
Software Version on the programmable Logic Circuit
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

metro1500PSTable 1.3.6.1.4.1.2544.1.3.1.3
Table of installed Power Supplies
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Metro1500PSEntry

metro1500PSEntry 1.3.6.1.4.1.2544.1.3.1.3.1
Installed METRO1500 Power Supplies
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Metro1500PSEntry  

metro1500PSNumber 1.3.6.1.4.1.2544.1.3.1.3.1.1
Number of installed Power Supply
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..32  

metro1500PSOn 1.3.6.1.4.1.2544.1.3.1.3.1.2
Is installed Power Supply On or Off
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500FanTable 1.3.6.1.4.1.2544.1.3.1.4
Table of installed Fans
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Metro1500FanEntry

metro1500FanEntry 1.3.6.1.4.1.2544.1.3.1.4.1
Installed METRO1500 Fans
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Metro1500FanEntry  

metro1500FanNumber 1.3.6.1.4.1.2544.1.3.1.4.1.1
Number of installed Fan
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

metro1500FanOn 1.3.6.1.4.1.2544.1.3.1.4.1.2
Is installed Fan On or Off
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500Converter 1.3.6.1.4.1.2544.1.3.5
OBJECT IDENTIFIER    

metro1500ConverterTable 1.1
Table of installed METRO1500 Converters
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Metro1500ConverterEntry

metro1500ConverterEntry 1.1.1
Installed METRO1500 Converters
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Metro1500ConverterEntry  

metro1500ConverterNumber 1.1.1.1
Slot Number of installed Converter Card
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..79  

metro1500RxLoc 1.1.1.2
Local Receiver has Signal (On) or Loss of Signal (Off)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500TxLoc 1.1.1.3
Local Transmitter is On or Off
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), alwaysOn(3), alwaysOff(4)  

metro1500TxLocC 1.1.1.4
Current of the local Transmitter in mA. This Entry is only available if a Current Sensor is installed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..200  

metro1500TxLocTemp 1.1.1.5
Temperature of the local Transmitter in Celsius. This Entry is only available if the Laser is cooled
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

metro1500RxRem 1.1.1.6
Remote Receiver has Signal (On) or Loss of Signal (Off)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500TxRem 1.1.1.7
Remote Transmitter is On or Off
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), alwaysOn(3), alwaysOff(4)  

metro1500TxRemC 1.1.1.8
Current of the Remote Transmitter in Milli Ampere. This Entry is only available if a Current Sensor is installed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..200  

metro1500TxRemTemp 1.1.1.9
Temperature of the Remote Transmitter in Celsius This Entry is only available if the Laser is cooled
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

metro1500RxRem2 1.1.1.10
2nd Remote receiver has Signal (On) or Loss of Signal (Off). (Only available if a 2nd Remote Receiver is installed)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500ClockState 1.1.1.11
Status of the Clock. This Entry is only available if a Clock is installed. If the Clock is enabled, and has an error output, and cannot synchronize to the Signal, the Clock fails.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), fail(3)  

metro1500ClockFreq 1.1.1.12
Frequency of the Clock in MBit/s. Only available if a Clock is installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

metro1500LocLoop 1.1.1.13
Local Loop is set to On or to Off
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500RemLoop 1.1.1.14
Remote Loop is set to On or to Off
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500ClockType 1.1.1.15
Type of the Clock. Only available, if a Clock is installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER multiClockLSModule(1), multiClockLS(2), multiClockFCGbE(3), multiClockOCxGbE(5), multiClockOCxFC(7), multiClockOCxGbEFC(9), multiClockFCGbEOnBoard(11), fixedClock125MbpsModule(21), fixedClock125Mbps(22), fixedClock155MbpsModule(31), fixedClock155Mbps(32), fixedClock200MbpsModule(41), fixedClock200Mbps(42), fixedClock266MbpsModule(51), fixedClock266Mbps(52), fixedClock622MbpsModule(61), fixedClock622Mbps(62), fixedClock1062MbpsModule(71), fixedClock1062Mbps(72), fixedClock1250MbpsModule(75), fixedClock1250Mbps(76), fixedClock2500MbpsModule(81), fixedClock2500Mbps(82), other(255)  

metro1500Switch 1.3.6.1.4.1.2544.1.3.10
OBJECT IDENTIFIER    

metro1500SwitchTable 1.3.6.1.4.1.2544.1.3.10.1
Table of installed METRO1500 Switches
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Metro1500SwitchEntry

metro1500SwitchEntry 1.3.6.1.4.1.2544.1.3.10.1.1
Installed METRO1500 Switches
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Metro1500SwitchEntry  

metro1500SwitchNumber 1.3.6.1.4.1.2544.1.3.10.1.1.1
Slot Number of installed Remote Optical Switch Card
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..79  

metro1500SwitchLine 1.3.6.1.4.1.2544.1.3.10.1.1.2
Active Line of Remote Optical Switch
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER lineA(1), lineB(2)  

metro1500SwitchMode 1.3.6.1.4.1.2544.1.3.10.1.1.3
Mode of Transmit Line of Remote Optical Switch
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER automatic(1), locked(2)  

metro1500SwitchLaserOn 1.3.6.1.4.1.2544.1.3.10.1.1.4
Shows if the reference Laser is On or Off
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500SwitchLineAavail 1.3.6.1.4.1.2544.1.3.10.1.1.5
Is Line A of Remote Optical Switch available?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER available(1), notAvailable(2)  

metro1500SwitchLineBavail 1.3.6.1.4.1.2544.1.3.10.1.1.6
Is Line B of Remote Optical Switch available
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER available(1), notAvailable(2)  

metro1500EthernetHub 1.3.6.1.4.1.2544.1.3.14
OBJECT IDENTIFIER    

metro1500EthernetHubTable 1.3.6.1.4.1.2544.1.3.14.1
Table of installed FSP-II Hub Cards
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Metro1500EthernetHubEntry

metro1500EthernetHubEntry 1.3.6.1.4.1.2544.1.3.14.1.1
Installed FSP-II Hub Cards
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Metro1500EthernetHubEntry  

metro1500EthernetHubNumber 1.3.6.1.4.1.2544.1.3.14.1.1.1
Slot Number of installed Hub Card
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..79  

metro1500EthernetHubPortEnable1 1.3.6.1.4.1.2544.1.3.14.1.1.10
is Hub Port 1 enabled ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

metro1500EthernetHubPortPartitionStatus1 1.3.6.1.4.1.2544.1.3.14.1.1.11
is Port 1 partitioned ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER partitioned(1), notPartitioned(2)  

metro1500EthernetHubPortLinkStatus1 1.3.6.1.4.1.2544.1.3.14.1.1.12
does Port 1 receive Link Pulses ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER linked(1), notLinked(2)  

metro1500EthernetHubPortPolarity1 1.3.6.1.4.1.2544.1.3.14.1.1.13
polarity of input signal at Port 1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER positive(1), negative(2)  

metro1500EthernetHubPortEnable2 1.3.6.1.4.1.2544.1.3.14.1.1.20
is Hub Port 2 enabled ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

metro1500EthernetHubPortPartitionStatus2 1.3.6.1.4.1.2544.1.3.14.1.1.21
is Port 2 partitioned ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER partitioned(1), notPartitioned(2)  

metro1500EthernetHubPortLinkStatus2 1.3.6.1.4.1.2544.1.3.14.1.1.22
does Port 2 receive Link Pulses ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER linked(1), notLinked(2)  

metro1500EthernetHubPortPolarity2 1.3.6.1.4.1.2544.1.3.14.1.1.23
polarity of input signal at Port 2
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER positive(1), negative(2)  

metro1500EthernetHubPortEnable3 1.3.6.1.4.1.2544.1.3.14.1.1.30
is Hub Port 3 enabled ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

metro1500EthernetHubPortPartitionStatus3 1.3.6.1.4.1.2544.1.3.14.1.1.31
is Port 3 partitioned ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER partitioned(1), notPartitioned(2)  

metro1500EthernetHubPortLinkStatus3 1.3.6.1.4.1.2544.1.3.14.1.1.32
does Port 3 receive Link Pulses ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER linked(1), notLinked(2)  

metro1500EthernetHubPortPolarity3 1.3.6.1.4.1.2544.1.3.14.1.1.33
polarity of input signal at Port 3
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER positive(1), negative(2)  

metro1500EthernetHubPortEnable4 1.3.6.1.4.1.2544.1.3.14.1.1.40
is Hub Port 4 enabled ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

metro1500EthernetHubPortPartitionStatus4 1.3.6.1.4.1.2544.1.3.14.1.1.41
is Port 4 partitioned ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER partitioned(1), notPartitioned(2)  

metro1500EthernetHubPortLinkStatus4 1.3.6.1.4.1.2544.1.3.14.1.1.42
does Port 4 receive Link Pulses ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER linked(1), notLinked(2)  

metro1500EthernetHubPortPolarity4 1.3.6.1.4.1.2544.1.3.14.1.1.43
polarity of input signal at Port 4
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER positive(1), negative(2)  

metro1500EthernetHubPortEnable5 1.3.6.1.4.1.2544.1.3.14.1.1.50
is Hub Port 5 enabled ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

metro1500EthernetHubPortPartitionStatus5 1.3.6.1.4.1.2544.1.3.14.1.1.51
is Port 5 partitioned ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER partitioned(1), notPartitioned(2)  

metro1500EthernetHubPortLinkStatus5 1.3.6.1.4.1.2544.1.3.14.1.1.52
does Port 5 receive Link Pulses ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER linked(1), notLinked(2)  

metro1500EthernetHubPortPolarity5 1.3.6.1.4.1.2544.1.3.14.1.1.53
polarity of input signal at Port 5
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER positive(1), negative(2)  

metro1500TDM 1.3.6.1.4.1.2544.1.3.15
OBJECT IDENTIFIER    

metro1500TDMTable 1.3.6.1.4.1.2544.1.3.15.1
Table of installed FSP-II TDM Cards
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Metro1500TDMEntry

metro1500TDMEntry 1.3.6.1.4.1.2544.1.3.15.1.1
Installed FSP-II TDM Cards
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Metro1500TDMEntry  

metro1500TDMNumber 1.3.6.1.4.1.2544.1.3.15.1.1.1
Slot Number of installed TDM Card
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..79  

metro1500TDMRxRem 1.3.6.1.4.1.2544.1.3.15.1.1.4
Does the remote receiver receive Light (on) or not (off)?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500TDMRxSync 1.3.6.1.4.1.2544.1.3.15.1.1.5
Is the input signal synchronized with the corresponding TDM card?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER sync(1), noSync(2)  

metro1500TDMTxRem 1.3.6.1.4.1.2544.1.3.15.1.1.6
State of the Remote Transmitter
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), alwaysOn(3), alwaysOff(4)  

metro1500TDMTxRemC 1.3.6.1.4.1.2544.1.3.15.1.1.7
Current of the remote Transmitter in mA
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..200  

metro1500TDMTxRemTemp 1.3.6.1.4.1.2544.1.3.15.1.1.8
Temperature of the remote Transmitter in Celsius
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

metro1500TDMLocLoop 1.3.6.1.4.1.2544.1.3.15.1.1.9
Loop for all Local Inputs enabled (on) or disabled (off)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500TDMLocModuleInst1 1.3.6.1.4.1.2544.1.3.15.1.1.20
is local Module 1 installed ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER installed(1), notInstalled(2)  

metro1500TDMLocModuleEnable1 1.3.6.1.4.1.2544.1.3.15.1.1.21
is local Module 1 enabled ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), notEnabled(2)  

metro1500TDMLocModuleRx1 1.3.6.1.4.1.2544.1.3.15.1.1.22
local receiver 1 gets signal (on)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500TDMLocModuleTx1 1.3.6.1.4.1.2544.1.3.15.1.1.23
state of the local transmitter
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), alwaysOn(3), alwaysOff(4)  

metro1500TDMLocModuleRemoteData1 1.3.6.1.4.1.2544.1.3.15.1.1.24
receiving data for this module from the remote side
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER data(1), noData(2)  

metro1500TDMLocModuleClockFrequency1 1.3.6.1.4.1.2544.1.3.15.1.1.25
data rate of the clock installed on local Module 1 in MBit/s
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

metro1500TDMLocModuleClockError1 1.3.6.1.4.1.2544.1.3.15.1.1.26
data rate and clock frequency are not synchronized
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER error(1), noError(2)  

metro1500TDMLocModuleInst2 1.3.6.1.4.1.2544.1.3.15.1.1.30
is local Module 2 installed ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER installed(1), notInstalled(2)  

metro1500TDMLocModuleEnable2 1.3.6.1.4.1.2544.1.3.15.1.1.31
is local Module 2 enabled ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), notEnabled(2)  

metro1500TDMLocModuleRx2 1.3.6.1.4.1.2544.1.3.15.1.1.32
local receiver 2 gets signal (on)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500TDMLocModuleTx2 1.3.6.1.4.1.2544.1.3.15.1.1.33
state of the local transmitter
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), alwaysOn(3), alwaysOff(4)  

metro1500TDMLocModuleRemoteData2 1.3.6.1.4.1.2544.1.3.15.1.1.34
receiving data for this module from the remote side
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER data(1), noData(2)  

metro1500TDMLocModuleClockFrequency2 1.3.6.1.4.1.2544.1.3.15.1.1.35
data rate of the clock installed on local Module 2 in MBit/s
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

metro1500TDMLocModuleClockError2 1.3.6.1.4.1.2544.1.3.15.1.1.36
data rate and clock frequency are not synchronized
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER error(1), noError(2)  

metro1500TDMLocModuleInst3 1.3.6.1.4.1.2544.1.3.15.1.1.40
is local Module 3 installed ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER installed(1), notInstalled(2)  

metro1500TDMLocModuleEnable3 1.3.6.1.4.1.2544.1.3.15.1.1.41
is local Module 3 enabled ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), notEnabled(2)  

metro1500TDMLocModuleRx3 1.3.6.1.4.1.2544.1.3.15.1.1.42
local receiver 3 gets signal (on)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500TDMLocModuleTx3 1.3.6.1.4.1.2544.1.3.15.1.1.43
state of the local transmitter
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), alwaysOn(3), alwaysOff(4)  

metro1500TDMLocModuleRemoteData3 1.3.6.1.4.1.2544.1.3.15.1.1.44
receiving data for this module from the remote side
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER data(1), noData(2)  

metro1500TDMLocModuleClockFrequency3 1.3.6.1.4.1.2544.1.3.15.1.1.45
data rate of the clock installed on local Module 3 in MBit/s
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

metro1500TDMLocModuleClockError3 1.3.6.1.4.1.2544.1.3.15.1.1.46
data rate and clock frequency are not synchronized
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER error(1), noError(2)  

metro1500TDMLocModuleInst4 1.3.6.1.4.1.2544.1.3.15.1.1.50
is local Module 4 installed ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER installed(1), notInstalled(2)  

metro1500TDMLocModuleEnable4 1.3.6.1.4.1.2544.1.3.15.1.1.51
is local Module 4 enabled ?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), notEnabled(2)  

metro1500TDMLocModuleRx4 1.3.6.1.4.1.2544.1.3.15.1.1.52
local receiver 4 gets signal (on)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

metro1500TDMLocModuleTx4 1.3.6.1.4.1.2544.1.3.15.1.1.53
state of the local transmitter
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), alwaysOn(3), alwaysOff(4)  

metro1500TDMLocModuleRemoteData4 1.3.6.1.4.1.2544.1.3.15.1.1.54
receiving data for this module from the remote side
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER data(1), noData(2)  

metro1500TDMLocModuleClockFrequency4 1.3.6.1.4.1.2544.1.3.15.1.1.55
data rate of the clock installed on local Module 4 in MBit/s
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

metro1500TDMLocModuleClockError4 1.3.6.1.4.1.2544.1.3.15.1.1.56
data rate and clock frequency are not synchronized
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER error(1), noError(2)  

metro1500Trap 1.3.6.1.4.1.2544.1.3.100
OBJECT IDENTIFIER    

metro1500HardwareAdded 1
Trap is sent when a new Module is inserted into the FSP-I Box
TRAP-TYPE    

metro1500HardwareDeleted 2
Trap is sent when a Module is removed from the FSP-I Box
TRAP-TYPE    

metro1500PSNotFail 3
Trap is sent when a Power Supply starts working
TRAP-TYPE    

metro1500PSFail 4
Trap is sent when a Power Supply fails
TRAP-TYPE    

metro1500FanNotFail 5
Trap is sent when a Fan starts working
TRAP-TYPE    

metro1500FanFail 6
Trap is sent when a Fan fails
TRAP-TYPE    

metro1500BusNotFail 7
Trap is sent when the internal Bus starts working again
TRAP-TYPE    

metro1500BusFail 8
Trap is sent when an internal Bus Failure occurs
TRAP-TYPE    

metro1500RxLocOn 20
Trap is sent when the local Receiver gets Signal
TRAP-TYPE    

metro1500RxLocOff 21
Trap is sent when the local Receiver has Loss of Signal
TRAP-TYPE    

metro1500TxLocOn 22
Trap is sent when the local Transmitter is switched on, Either this trap or Trap #20 should be disabled in the Configuration because they are typically sent at the same Time.
TRAP-TYPE    

metro1500TxLocOff 23
Trap is sent when the local Transmitter is switched off, Either this trap or Trap #21 should be disabled in the Configuration because they are typically sent at the same Time.
TRAP-TYPE    

metro1500RxRemOn 24
Trap is sent when the remote Receiver gets Signal
TRAP-TYPE    

metro1500RxRemOff 25
Trap is sent when the remote Receiver has Loss of Signal
TRAP-TYPE    

metro1500TxRemOn 26
Trap is sent when the remote Transmitter is switched on, Either this trap or Trap #24 should be disabled in the Configuration because they are typically sent at the same Time.
TRAP-TYPE    

metro1500TxRemOff 27
Trap is sent when the remote Transmitter is switched off, Either this trap or Trap #25 should be disabled in the Configuration because they are typically sent at the same Time.
TRAP-TYPE    

metro1500RxRem2On 28
Trap is sent when the 2nd remote Receiver gets Signal. This Trap is only sent if there is a 2nd remote Receiver.
TRAP-TYPE    

metro1500RxRem2Off 29
Trap is sent when the 2nd remote Receiver has Loss of Signal. This Trap is only sent if there is a 2nd remote Receiver.
TRAP-TYPE    

metro1500TxRem2On 30
Trap is sent when the 2nd remote Transmitter is switched on, Either this Trap or Trap #28 should be disabled in the Configuration because they are typically sent at the same Time. This Trap is only sent if there is a 2nd remote Receiver.
TRAP-TYPE    

metro1500TxRem2Off 31
Trap is sent when the 2nd remote Transmitter is switched off, Either this trap or Trap #29 should be disabled in the Configuration because they are typically sent at the same Time.
TRAP-TYPE    

metro1500ClockNoFail 32
Trap is sent if a Clock is installed and can synchronize with the input Signal. This Trap is not sent if the installed Clock does not have an error Output
TRAP-TYPE    

metro1500ClockFail 33
Trap is sent if a Clock is installed and can not synchronize with the input Signal. This trap is not sent if the installed Clock does not have an error Output
TRAP-TYPE    

metro1500ClockChangeFrequency 34
Trap is sent if a multi frequency Clock is installed and changes its frequency.
TRAP-TYPE    

metro1500LocLoopOn 35
Trap is sent if Local Loop is set to On.
TRAP-TYPE    

metro1500LocLoopOff 36
Trap is sent if Local Loop is set to Off.
TRAP-TYPE    

metro1500RemLoopOn 37
Trap is sent if Remote Loop is set to On.
TRAP-TYPE    

metro1500RemLoopOff 38
Trap is sent if Remote Loop is set to Off.
TRAP-TYPE    

metro1500switchReferenceLaserOn 40
Trap is sent when the Reference Laser is switched on
TRAP-TYPE    

metro1500switchReferenceLaserOff 41
Trap is sent when the Reference Laser is switched off
TRAP-TYPE    

metro1500switchToA 42
Trap is sent when the Switch switches to Line A
TRAP-TYPE    

metro1500switchToB 43
Trap is sent when the Switch switches to Line B
TRAP-TYPE    

metro1500switchAutomatic 44
Trap is sent when the Switch is going to Automatic State
TRAP-TYPE    

metro1500switchLocked 45
Trap is sent when the Switch is going to Locked State
TRAP-TYPE    

metro1500switchLineAavail 46
Trap is sent when the Switch Line A is available
TRAP-TYPE    

metro1500switchLineANotAvail 47
Trap is sent when the Switch Line A is not available
TRAP-TYPE    

metro1500switchLineBavail 48
Trap is sent when the Switch Line B is available
TRAP-TYPE    

metro1500switchLineBNotAvail 49
Trap is sent when the Switch Line B is not available
TRAP-TYPE    

metro1500repeatedMessage 50
Trap is sent, after three times the same trap is sent (instead of the fourth one). The original trap is suppressed for one minute.
TRAP-TYPE    

metro1500INNCDown 51
Trap is sent, when the Inter NEMI Network Connection (INNC) is down.
TRAP-TYPE    

metro1500INNCUp 52
Trap is sent, when the Inter NEMI Network Connection (INNC) is up.
TRAP-TYPE    

metro1500EthernetHubPortEnable 60
Trap is sent, when one of the ports of the Ethernet Hub is enabled by the management software (default). Use SNMP Get to get the Port Number.
TRAP-TYPE    

metro1500EthernetHubPortDisable 61
Trap is sent, when one of the ports of the Ethernet Hub is disabled by the management Software. Use SNMP Get to get the Port number.
TRAP-TYPE    

metro1500EthernetHubPortPartitioned 62
Trap is sent, when a Hub Port is disabled by the Hub Hardware. Use SNMP Get to get the Port Number.
TRAP-TYPE    

metro1500EthernetHubPortNotPartitioned 63
Trap is sent, when a Hub Port is enabled by the Hub Hardware (default). Use SNMP Get to get the Port Number.
TRAP-TYPE    

metro1500EthernetHubPortLinkPulses 64
Trap is sent, when a Hub Port starts receiving Link Pulses. Use SNMP Get to get the Port Number
TRAP-TYPE    

metro1500EthernetHubPortNoLinkPulses 65
Trap is sent, when a Hub Port stops receiving Link Pulses. Use SNMP Get to get the Port Number
TRAP-TYPE    

metro1500TDMRemoteSyncLoss 70
Trap is sent, when the synchronisation of the incoming remote data stream is lost
TRAP-TYPE    

metro1500TDMRemoteSync 71
Trap is sent, when the synchronisation of the incoming remote data stream is established
TRAP-TYPE    

metro1500TDMLocModuleEnabled1 72
Trap is sent, when local module 1 is enabled by software
TRAP-TYPE    

metro1500TDMLocModuleDisable1 73
Trap is sent, when local module 1 is disabled by software
TRAP-TYPE    

metro1500TDMLocModuleEnabled2 74
Trap is sent, when local module 2 is enabled by software
TRAP-TYPE    

metro1500TDMLocModuleDisable2 75
Trap is sent, when local module 2 is disabled by software
TRAP-TYPE    

metro1500TDMLocModuleEnabled3 76
Trap is sent, when local module 3 is enabled by software
TRAP-TYPE    

metro1500TDMLocModuleDisable3 77
Trap is sent, when local module 3 is disabled by software
TRAP-TYPE    

metro1500TDMLocModuleEnabled4 78
Trap is sent, when local module 4 is enabled by software
TRAP-TYPE    

metro1500TDMLocModuleDisable4 79
Trap is sent, when local module 4 is disabled by software
TRAP-TYPE    

metro1500TDMLocModuleRxOn1 88
Trap is sent, when the local receiver 1 of a TDM card gets modulated signal
TRAP-TYPE    

metro1500TDMLocModuleRxOff1 89
Trap is sent, when the local receiver 1 of a TDM card doesn't get modulated signal
TRAP-TYPE    

metro1500TDMLocModuleRxOn2 90
Trap is sent, when the local receiver 2 of a TDM card gets modulated signal
TRAP-TYPE    

metro1500TDMLocModuleRxOff2 91
Trap is sent, when the local receiver 2 of a TDM card doesn't get modulated signal
TRAP-TYPE    

metro1500TDMLocModuleRxOn3 92
Trap is sent, when the local receiver 3 of a TDM card gets modulated signal
TRAP-TYPE    

metro1500TDMLocModuleRxOff3 93
Trap is sent, when the local receiver 3 of a TDM card doesn't get modulated signal
TRAP-TYPE    

metro1500TDMLocModuleRxOn4 94
Trap is sent, when the local receiver 4 of a TDM card gets modulated signal
TRAP-TYPE    

metro1500TDMLocModuleRxOff4 95
Trap is sent, when the local receiver 4 of a TDM card doesn't get modulated signal
TRAP-TYPE    

metro1500TDMLocModuleData1 104
Trap is sent, when data from the remote side is available for this TDM channel
TRAP-TYPE    

metro1500TDMLocModuleNoData1 105
Trap is sent, when no data from the remote side is available for this TDM channel
TRAP-TYPE    

metro1500TDMLocModuleData2 106
Trap is sent, when data from the remote side is available for this TDM channel
TRAP-TYPE    

metro1500TDMLocModuleNoData2 107
Trap is sent, when no data from the remote side is available for this TDM channel
TRAP-TYPE    

metro1500TDMLocModuleData3 108
Trap is sent, when data from the remote side is available for this TDM channel
TRAP-TYPE    

metro1500TDMLocModuleNoData3 109
Trap is sent, when no data from the remote side is available for this TDM channel
TRAP-TYPE    

metro1500TDMLocModuleData4 110
Trap is sent, when data from the remote side is available for this TDM channel
TRAP-TYPE    

metro1500TDMLocModuleNoData4 111
Trap is sent, when no data from the remote side is available for this TDM channel
TRAP-TYPE    

metro1500TDMLocModuleClockFail1 120
Trap is sent, when the Data Rate of the local input signal doesn't match the Data Rate of the local clock
TRAP-TYPE    

metro1500TDMLocModuleClockNoFail1 121
Trap is sent, when the Data Rate of the local input signal matches the Data Rate of the local clock
TRAP-TYPE    

metro1500TDMLocModuleClockFail2 122
Trap is sent, when the Data Rate of the local input signal doesn't match the Data Rate of the local clock
TRAP-TYPE    

metro1500TDMLocModuleClockNoFail2 123
Trap is sent, when the Data Rate of the local input signal matches the Data Rate of the local clock
TRAP-TYPE    

metro1500TDMLocModuleClockFail3 124
Trap is sent, when the Data Rate of the local input signal doesn't match the Data Rate of the local clock
TRAP-TYPE    

metro1500TDMLocModuleClockNoFail3 125
Trap is sent, when the Data Rate of the local input signal matches the Data Rate of the local clock
TRAP-TYPE    

metro1500TDMLocModuleClockFail4 126
Trap is sent, when the Data Rate of the local input signal doesn't match the Data Rate of the local clock
TRAP-TYPE    

metro1500TDMLocModuleClockNoFail4 127
Trap is sent, when the Data Rate of the local input signal matches the Data Rate of the local clock
TRAP-TYPE