MITEL-IperaVoiceLAN-MIB

File: MITEL-IperaVoiceLAN-MIB.mib (33096 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1213-MIB
MITEL-MIB

Imported symbols

OBJECT-TYPE TRAP-TYPE DisplayString
sysName mitelAppCallServer mitelConfCompliances
mitelConfAgents mitelGrpIpera3000 mitelIdCsIpera3000

Defined Types

DateAndTime  
OCTET STRING Size(8|11)    

MitelIpera3000AlarmLevelType  
INTEGER almClear(1), almMinor(2), almMajor(3), almCritical(4)    

MitelIpera3000ShutdownCause  
INTEGER resourcesLowReboot(1), softwareFailureReboot(2), hardwareFailureReboot(3), softwareUpgradedReboot(4), databaseRestoreReboot(5), intermediateReboot(6), l2SwitchFailureReboot(7), remoteAlarmButtonReboot(8), programmedReboot(9), maintenanceCommandReboot(10), maintenanceCommandShutdown(11), shutdownCauseNotReported(12)    

MitelIpera3000ResetCause  
INTEGER pushButtonReset(1), softwareInitiatedReset(2), powerOnReset(3), systemFaultReset(4), uknownReset(5)    

MitelIpera3000CategoryTableEntry  
SEQUENCE    
  mitelIpera3000CatTblIndex INTEGER
  mitelIpera3000CatTblAvailable INTEGER
  mitelIpera3000CatTblUnavailable INTEGER
  mitelIpera3000CatTblLevel MitelIpera3000AlarmLevelType
  mitelIpera3000CatTblMinorThresh INTEGER
  mitelIpera3000CatTblMajorThresh INTEGER
  mitelIpera3000CatTblCriticalThresh INTEGER
  mitelIpera3000CatTblName DisplayString

MitelIpera3000ResTableEntry  
SEQUENCE    
  mitelIpera3000ResTblPriSysName DisplayString
  mitelIpera3000ResTblPriCEID DisplayString
  mitelIpera3000ResTblClusterName DisplayString
  mitelIpera3000ResTblDetectDate DateAndTime
  mitelIpera3000ResTblStatus INTEGER

Defined Values

mitelAppCsIpera3000 1.3.6.1.4.1.1027.4.1.1.2
OBJECT IDENTIFIER    

mitelIpera3000System 1.3.6.1.4.1.1027.4.1.1.2.1
OBJECT IDENTIFIER    

mitelIpera3000Alarms 1.3.6.1.4.1.1027.4.1.1.2.2
OBJECT IDENTIFIER    

mitelIpera3000Resilience 1.3.6.1.4.1.1027.4.1.1.2.4
OBJECT IDENTIFIER    

mitelIpera3000Applications 1.3.6.1.4.1.1027.4.1.1.2.5
OBJECT IDENTIFIER    

mitelIpera3000SysCapDisplay 1.3.6.1.4.1.1027.4.1.1.2.1.2
OBJECT IDENTIFIER    

mitelIpera3000CEID 1.3.6.1.4.1.1027.4.1.1.2.1.3
The Cluster Element ID is a number to identify a node that is in a cluster. This number is not guaranteed to be unique.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mitelIpera3000PNI 1.3.6.1.4.1.1027.4.1.1.2.1.4
The Primary Node ID is a number assigned to a cluster of nodes for a dialing plan. Though a good candidate to identify a cluster, it is not unique across a network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mitelIpera3000ClusterName 1.3.6.1.4.1.1027.4.1.1.2.1.5
The Cluster Name is a unique name that clearly identifies a cluster. Introduced in 3300 6.0 release.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mitelIpera3000IPUsrLicPurchased 1.3.6.1.4.1.1027.4.1.1.2.1.2.1
The number of the user license purchased.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mitelIpera3000IPUsrLicUsed 1.3.6.1.4.1.1027.4.1.1.2.1.2.2
The number of the user license used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mitelIpera3000IPDevLicPurchased 1.3.6.1.4.1.1027.4.1.1.2.1.2.3
The number of the device license purchased.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mitelIpera3000IPDevLicUsed 1.3.6.1.4.1.1027.4.1.1.2.1.2.4
The number of the device license used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mitelIpera3000AlmLevel 1.3.6.1.4.1.1027.4.1.1.2.2.1
The current overall alarm level for the call server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MitelIpera3000AlarmLevelType  

mitelIpera3000AlmDetectDate 1.3.6.1.4.1.1027.4.1.1.2.2.2
Defines when the alarm was detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DateAndTime  

mitelIpera3000AlmNbrCategories 1.3.6.1.4.1.1027.4.1.1.2.2.3
Defines the number of associated entries in the categories table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mitelIpera3000CategoryTable 1.3.6.1.4.1.1027.4.1.1.2.2.4
Table defining the alarm state for individual call server categories. There will be multiple categories for each call server. The number of rows in the table is determined by the total of the mitelIpera3000AlmTblNbrCategories value.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MitelIpera3000CategoryTableEntry

mitelIpera3000CategoryTableEntry 1.3.6.1.4.1.1027.4.1.1.2.2.4.1
A row defining a single category.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MitelIpera3000CategoryTableEntry  

mitelIpera3000CatTblIndex 1.3.6.1.4.1.1027.4.1.1.2.2.4.1.1
Differentiates the different category reports for the call server. The first category will have an index value of 1, the second will have 2, etc. up to the last category report. The highest possible index value is 100.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

mitelIpera3000CatTblAvailable 1.3.6.1.4.1.1027.4.1.1.2.2.4.1.2
The number of available resources of this type of category on this call server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mitelIpera3000CatTblUnavailable 1.3.6.1.4.1.1027.4.1.1.2.2.4.1.3
The number of unavailable resources of this type of category on this call server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mitelIpera3000CatTblLevel 1.3.6.1.4.1.1027.4.1.1.2.2.4.1.4
Defines the alarm level for this category on this call server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MitelIpera3000AlarmLevelType  

mitelIpera3000CatTblMinorThresh 1.3.6.1.4.1.1027.4.1.1.2.2.4.1.5
The percentage unavailable threshold indicating a minor alarm on this call server category.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mitelIpera3000CatTblMajorThresh 1.3.6.1.4.1.1027.4.1.1.2.2.4.1.6
The percentage unavailable threshold indicating a major alarm on this call server category.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mitelIpera3000CatTblCriticalThresh 1.3.6.1.4.1.1027.4.1.1.2.2.4.1.7
The percentage unavailable threshold indicating a critical alarm on this call server category.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mitelIpera3000CatTblName 1.3.6.1.4.1.1027.4.1.1.2.2.4.1.8
The name of this resource category.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mitelIpera3000TrapAlmShutdownCause 1.3.6.1.4.1.1027.4.1.1.2.2.5
This value is only useful for the shutdown trap. This scalar is not persistent. A GET on this scalar will always return: shutdownCauseNotReported (11). Defines the last known shutdown cause. This shutdown is the last orderly shutdown of the system. Do not confuse this with the ResetCause. e.g. this value would have no meaning if the shutdown cause was from a power failure, but it does have meaning if the shutdown was due to a scheduled reboot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MitelIpera3000ShutdownCause  

mitelIpera3000TrapAlmShutdownDetailedCause 1.3.6.1.4.1.1027.4.1.1.2.2.6
The detailed reason for the last shutdown: This value is only useful for the shutdown trap. This scalar is not persistent. A GET on this scalar will always return: shutdownCauseNotReported. resourcesLowShutdown (1), -- System reboot to reclaim resources. softwareComponentFailureShutdown (2), -- System reboot due to a serious software fault. softwareUpgradedShutdown (3), -- System reboot because software was upgraded. databaseRestoreShutdown (4), -- System reboot because a database was restored. intermediateShutdown (5), -- System reboot during startup because of a configuration change. l2SwitchFailureShutdown (6), -- Layer 2 switch shutdown system to restore internal communications. remoteAlarmButtonShutdown (7), -- System reboot because user pressed remote alarm button. softRestart (8), -- System reboot because call control issues a soft restart. callControlProgrammedReboot (9), -- by programmed reboot in CC -- like a scheduled reboot. callControlHardwareTrap (10), -- by hardware trap in CC callControlSoftwareTrap (11), -- by software trap in CC callControlLOADCommand (12), -- by LOAD command in CC callControlDiskFailure (13), -- because of disk failure callControlHardwareReset (14), -- by hardware reset in CC callControlMemoryFragmentation (15), -- because of memory fragmentation in CC callControlVxWorksTaskDoesNotExist (16), -- because VxWorks task does not exist callControlVxWorksTaskSuspended (17), -- because VxWorks task is suspended callControlVxWorksTaskNotResponding (18), -- because VxWorks task is not responding callControlVxWorksRestart (19), -- because of unknown VxWorks restart callControlUnkownProcess (20), -- by unknown process shutdownCauseNotReported (21) -- Shutdown cause not reported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mitelIpera3000AlmResetCause 1.3.6.1.4.1.1027.4.1.1.2.2.7
Defines the last known reset cause. As best can be determined by the platform.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MitelIpera3000ResetCause  

mitelIpera3000AlmResetCauseBITS 1.3.6.1.4.1.1027.4.1.1.2.2.8
The reset bits for this system. hardReset(0), softReset(1), busMonitorReset(2), cpuSwWatchdogReset(3), checkStopReset(4), JTAGReset(5), CPLDWatchdogReset(6), powerOnReset(7), softwareReset(8), pushButtonReset(9) If the bit is set, then that reason is responsible for the system reset. Note: combinations of bits set is possible. Most significant bit set is typically the reason for the reset. Typical Combinations are: 0x0003 - external hard reset 0x0010 - check stop reset 0x0043 - CPLD watch dog reset 0x0100 - software initiated reset no external hard reset asserted 0x0103 - software initiated reset 0x0200 - push button reset no external hard hard reset asserted 0x0203 - push button reset
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mitelIpera3000ResTable 1.3.6.1.4.1.1027.4.1.1.2.4.1
Table defining the resiliency state for the primary ICP that has gone into resilient mode.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MitelIpera3000ResTableEntry

mitelIpera3000ResTableEntry 1.3.6.1.4.1.1027.4.1.1.2.4.1.1
A row defining a single resiliency table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MitelIpera3000ResTableEntry  

mitelIpera3000ResTblPriSysName 1.3.6.1.4.1.1027.4.1.1.2.4.1.1.1
The System Name of the primary ICP. Empty strigs are no allowed. The index column for the Resilience Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mitelIpera3000ResTblPriCEID 1.3.6.1.4.1.1027.4.1.1.2.4.1.1.2
The Cluster Element ID of the primary ICP.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mitelIpera3000ResTblClusterName 1.3.6.1.4.1.1027.4.1.1.2.4.1.1.3
The Cluster Name of group that the primary and secondary are a member of.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

mitelIpera3000ResTblDetectDate 1.3.6.1.4.1.1027.4.1.1.2.4.1.1.4
Defines when the alarm was detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DateAndTime  

mitelIpera3000ResTblStatus 1.3.6.1.4.1.1027.4.1.1.2.4.1.1.5
Status of the entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER firstSetFailover(1), healthCheckComplete(2), handOffComplete(3)  

mitelIpera3000Notifications 1.3.6.1.4.1.1027.4.1.1.2.3
OBJECT IDENTIFIER    

mitelIpera3000NotifAlarm 301
This notification is generated whenever an alarm condition is detected or cleared. The manager is expected to retrieve the corresponding alarm and category table information.
TRAP-TYPE    

mitelIpera3000ShutdownAlarm 302
This notification is generated whenever the system can detect a shutdown of the system.
TRAP-TYPE    

mitelIpera3000RestartCompleteAlarm 303
This notification is generated whenever the system has completed booting and is now opperational. The Reset Cause can give a post mortum reason for the startup.
TRAP-TYPE    

mitelIpera3000NotifResiltFirstSetFailover 501
This notification is generated when the first set fails-over from a primary to secondary node.
TRAP-TYPE    

mitelIpera3000NotifResiltHealthCheckComplete 502
This notification is generated when the primary ICP has now recovered. This means that the primary ICP has passed a system health check as determined by the resiliency application on this node.
TRAP-TYPE    

mitelIpera3000NotifResiltHandoffComplete 503
This notification is generated when all phones, from a particular primary ICP, that had failed over to this node have completed handoff back to the primary ICP.
TRAP-TYPE    

mitelComplIpera3000 1.3.6.1.4.1.1027.5.1.4
OBJECT IDENTIFIER    

mitelGrpIpera3000System 1.3.6.1.4.1.1027.5.2.4.1
OBJECT IDENTIFIER    

mitelGrpIpera3000Alarms 1.3.6.1.4.1.1027.5.2.4.2
OBJECT IDENTIFIER    

mitelAgentIpera3000 1.3.6.1.4.1.1027.5.3.3
OBJECT IDENTIFIER