MODULES-MIB

File: MODULES-MIB.mib (138160 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
GEN-MIB

Imported symbols

IpAddress Counter OBJECT-TYPE
DisplayString lannet

Defined Types

EthAgEntry  
SEQUENCE    
  ethAgId INTEGER
  ethAgPerfBusSelection INTEGER

EthGroupEntry  
SEQUENCE    
  ethGroupId INTEGER
  ethGroupFIFO INTEGER
  ethGroup10BTPlus INTEGER
  ethGroupIntPortsRedundancy INTEGER
  ethGroupBackboneMode INTEGER
  ethGroupFOIRLPlusMode INTEGER
  ethGroupWrongPortSelection INTEGER
  ethGroupBackupBus INTEGER
  ethGroupSingleBusMode INTEGER
  ethGroupSpecificOID OBJECT IDENTIFIER
  ethGroup10FBPlus INTEGER
  ethGroupMasterClock INTEGER
  ethGroupIdleTrx INTEGER
  ethGroupTotalFrames Counter
  ethGroupTotalOctets Counter
  ethGroupTotalErrors Counter
  ethGroupBridgeMode INTEGER
  ethGroupBroadcastPkts Counter
  ethGroupMulticastPkts Counter

EthPortEntry  
SEQUENCE    
  ethPortGroupId INTEGER
  ethPortId INTEGER
  ethPortFunctionalStatus INTEGER
  ethPortManPart INTEGER
  ethPortJabber INTEGER
  ethPortNoAUILoop INTEGER
  ethPortMJLP INTEGER
  ethPortFIFO INTEGER
  ethPortAutoPartitionState INTEGER
  ethPortSQETest INTEGER
  ethPortLastSourceAddr OCTET STRING
  ethPortUserStatus INTEGER
  ethPortMainBusSelection INTEGER
  ethPortTraffic Counter
  ethPortFramesReceivedOK Counter
  ethPortRunts Counter
  ethPortPacketErrors Counter
  ethPortSpecificOID OBJECT IDENTIFIER
  ethPortCollisions Counter
  ethPortPartitions Counter
  ethPortPygmys Counter
  ethPortJabberCounter Counter
  ethPortCoupling INTEGER
  ethPortPolarity INTEGER
  ethPortReadableFrames Counter
  ethPortReadableOctets Counter
  ethPortFCSErrors Counter
  ethPortAlignmentErrors Counter
  ethPortFramesTooLong Counter
  ethPortLateEvents Counter
  ethPortVeryLongEvents Counter
  ethPortDataRateMismatches Counter
  ethPortTotalErrors Counter
  ethPortSourceAddrChanges Counter
  ethPortOperStatus INTEGER
  ethPortBroadcastPkts Counter
  ethPortMulticastPkts Counter

EthIntPortEntry  
SEQUENCE    
  ethIntPortGroupId INTEGER
  ethIntPortId INTEGER
  ethIntPortPartition INTEGER
  ethIntPortJabber INTEGER
  ethIntPortBackedUp INTEGER

EthBusPerfEntry  
SEQUENCE    
  ethBusPerfAgId INTEGER
  ethBusPerfId INTEGER
  ethBusTrafficBuffer OCTET STRING
  ethBusTrafficThresh INTEGER
  ethBusPeakTraffic INTEGER
  ethBusTotalCollisions Counter
  ethBusTotalPackets Counter
  ethBusTotalErrors Counter
  ethBusTraffic INTEGER
  ethBusUtilization INTEGER
  ethBusPeakUtilization INTEGER
  ethBusThresholdStatus OCTET STRING

EthBusClockEntry  
SEQUENCE    
  ethBusClockBusId INTEGER
  ethBusClockId INTEGER
  ethBusClockTestResult INTEGER

FethPortEntry  
SEQUENCE    
  fethPortGroupId INTEGER
  fethPortId INTEGER
  fethPortFunctionalStatus INTEGER
  fethPortFIFO INTEGER
  fethPortOperStatus INTEGER
  fethPortAutoPartitionState INTEGER
  fethPortFramesReceived Counter
  fethPortFramesTransmitted Counter
  fethPortTotalErrors Counter
  fethPortFramesTransmittedOK Counter
  fethPortCollisionFrames Counter
  fethPortAlignmentErrors Counter
  fethPortRxErrors Counter
  fethPortReadableFrames Counter
  fethPortUpper32ReadableOctets Counter
  fethPortLower32ReadableOctets Counter
  fethPortFCSErrors Counter
  fethPortFrameTooLongs Counter
  fethPortShortEvents Counter
  fethPortRunts Counter
  fethPortLateEvents Counter
  fethPortVeryLongEvents Counter
  fethPortDataRateMismatches Counter
  fethPortAutoPartitions Counter
  fethPortSymbolErrors Counter
  fethPortLastSourceAddress OCTET STRING
  fethPortSourceAddrChanges Counter
  fethPortMode INTEGER
  fethPortLinkRedundancyMode INTEGER
  fethPortLinkRedundancyStatus INTEGER
  fethPortDormantLinkFunctionalStatus INTEGER
  fethPortUpper32TransmittedOctets Counter
  fethPortLower32TransmittedOctets Counter
  fethPortBroadcastReceivedFrames Counter
  fethPortMulticastReceivedFrames Counter
  fethPortEnablePHY INTEGER

FethGroupEntry  
SEQUENCE    
  fethGroupId INTEGER
  fethGroupOperStatus INTEGER
  fethGroupUtilization INTEGER
  fethGroupTotalFrames Counter
  fethGroupUpper32TotalOctets Counter
  fethGroupLower32TotalOctets Counter
  fethGroupTotalErrors Counter
  fethGroupFefiEnable INTEGER

TokRingEntry  
SEQUENCE    
  tokRingAgId INTEGER
  tokRingId INTEGER
  tokRingLeftSlot INTEGER
  tokRingRightSlot INTEGER
  tokRingTrafficBuffer OCTET STRING
  tokRingTrafficThresh INTEGER
  tokRingPeakTraffic INTEGER
  tokRingNumberOfStations INTEGER
  tokRingConfiguration OCTET STRING
  tokRingBeaconing INTEGER
  tokRingBeaconingStation OCTET STRING
  tokRingStationsMatch INTEGER
  tokRingTraffic INTEGER
  tokRingSecurityMethod INTEGER
  tokRingSecurityPolicy OCTET STRING
  tokRingSecureAddr OCTET STRING
  tokRingLastViolation OCTET STRING
  tokRingUtilization INTEGER
  tokRingPeakUtilization INTEGER
  tokRingBeaconingResolution INTEGER
  tokRingThresholdStatus OCTET STRING
  tokRingActiveMonitor OCTET STRING

TokGroupEntry  
SEQUENCE    
  tokGroupId INTEGER
  tokGroupAutoRightLoop INTEGER
  tokGroupAutoLeftLoop INTEGER
  tokGroupManRightLoop INTEGER
  tokGroupManLeftLoop INTEGER
  tokGroupRightNeighbor INTEGER
  tokGroupLeftNeighbor INTEGER
  tokGroupIOMode INTEGER
  tokGroupBridgeMode INTEGER
  tokGroupManLinkLoop INTEGER
  tokGroupManBusLoop INTEGER
  tokGroupAutoLinkLoop INTEGER
  tokGroupAutoBusLoop INTEGER
  tokGroupSpecificOID OBJECT IDENTIFIER
  tokGroupStarSpeedDetect INTEGER
  tokGroupLobeSpeedDetect INTEGER
  tokGroupLSTBeaconing INTEGER
  tokGroupLSTBeaconThresh INTEGER

TokGroupRingEntry  
SEQUENCE    
  tokGroupRingGroupId INTEGER
  tokGroupRingId INTEGER
  tokGroupRingSpeed INTEGER
  tokGroupRingInserted INTEGER
  tokGroupRingStatus INTEGER

TokPortEntry  
SEQUENCE    
  tokPortGroupId INTEGER
  tokPortId INTEGER
  tokPortBypass INTEGER
  tokPortConnected INTEGER
  tokPortTCP INTEGER
  tokPortCableFault INTEGER
  tokPortFunctionalStatus INTEGER
  tokPortLastSourceAddr OCTET STRING
  tokPortSpecificOID OBJECT IDENTIFIER
  tokPortRingSpeedError INTEGER
  tokPortSpeedDetect INTEGER
  tokPortRingId INTEGER
  tokPortMapping INTEGER

TokRingStationEntry  
SEQUENCE    
  tokRingStationRingId INTEGER
  tokRingStationMAC OCTET STRING
  tokRingStationLineErrors Counter
  tokRingStationInternalErrors Counter
  tokRingStationBurstErrors Counter
  tokRingStationACErrors Counter
  tokRingStationAbortsTrans Counter
  tokRingStationLostFrames Counter
  tokRingStationReceiveCongErrors Counter
  tokRingStationFramesCopied Counter
  tokRingStationFrequencyErrors Counter
  tokRingStationTokenErrors Counter
  tokRingStationTotalErrors Counter
  tokRingStationFunctionalType INTEGER

TokIntPortEntry  
SEQUENCE    
  tokIntPortGroupId INTEGER
  tokIntPortId INTEGER
  tokIntPortLeftNeighbor INTEGER
  tokIntPortRightNeighbor INTEGER
  tokIntPortManLeftLoop INTEGER
  tokIntPortManRightLoop INTEGER
  tokIntPortAutoLeftLoop INTEGER
  tokIntPortAutoRightLoop INTEGER

TsGroupEntry  
SEQUENCE    
  tsGroupId INTEGER
  tsGroupLATStatus INTEGER
  tsGroupOperationMode INTEGER

LtalkPortEntry  
SEQUENCE    
  ltalkPortGroupId INTEGER
  ltalkPortId INTEGER
  ltalkPortTest INTEGER
  ltalkPortTestResult INTEGER
  ltalkPortJam INTEGER

ClGroupEntry  
SEQUENCE    
  clGroupId INTEGER
  clGroupClockRedundancy INTEGER
  clGroupMainClock INTEGER
  clGroupTestClocks INTEGER

ClPortEntry  
SEQUENCE    
  clPortGroupId INTEGER
  clPortId INTEGER
  clPortFunctionalStatus INTEGER

IwrGroupEntry  
SEQUENCE    
  iwrGroupId INTEGER
  iwrOperState INTEGER
  iwrPMState INTEGER
  iwrIOMState INTEGER
  iwrEthernetMode INTEGER
  iwrPrimaryFDDIInsert INTEGER
  iwrSecondaryFDDIInsert INTEGER

IwrWANEntry  
SEQUENCE    
  iwrWANGroupId INTEGER
  iwrWANPortId INTEGER
  iwrWANConnection INTEGER
  iwrWANPortCableType INTEGER

IwrInterfaceEntry  
SEQUENCE    
  iwrInterfaceGroupId INTEGER
  iwrInterfaceId INTEGER
  iwrInterfaceAddr IpAddress
  iwrInterfaceMask IpAddress
  iwrInterfaceMacAddress OCTET STRING

ItrGroupEntry  
SEQUENCE    
  itrGroupId INTEGER
  itrMainSWVersion DisplayString
  itrConfigState INTEGER
  itrModuleState INTEGER

ItrLinkEntry  
SEQUENCE    
  itrLinkGroupId INTEGER
  itrLinkPortId INTEGER
  itrLinkIf INTEGER
  itrLinkMode INTEGER
  itrLinkAsyncRate INTEGER
  itrLinkSyncRate INTEGER
  itrLinkParity INTEGER
  itrLinkParityEvenOdd INTEGER
  itrLinkStopBit INTEGER
  itrLinkRemoteLANConn INTEGER
  itrLinkFunctionalStatus INTEGER
  itrLinkAdminStatus INTEGER
  itrLinkReset INTEGER
  itrLinkConnectionStatus INTEGER
  itrLinkDataBits INTEGER
  itrLinkControlSignalsMode INTEGER
  itrLinkParityType INTEGER

LntFddiPortEntry  
SEQUENCE    
  lntFddiPortGroupId INTEGER
  lntFddiPortId INTEGER
  lntFddiPortMACCurrentPath INTEGER
  lntFddiPortOpticalSwitchExist INTEGER
  lntFddiPortRingConfiguration INTEGER
  lntFddiPortLineStatusA INTEGER
  lntFddiPortLineStatusB INTEGER
  lntFddiPortRxTotalPackets Counter
  lntFddiPortRxTotalOctets Counter
  lntFddiPortTxTotalPackets Counter
  lntFddiPortTxTotalOctets Counter
  lntFddiPortIPXtoFDDIMatching INTEGER
  lntFddiPortFDDItoIPXMatching INTEGER

Defined Values

eth 1.3.6.1.4.1.81.12
OBJECT IDENTIFIER    

tok 1.3.6.1.4.1.81.13
OBJECT IDENTIFIER    

ts 1.3.6.1.4.1.81.14
OBJECT IDENTIFIER    

ltalk 1.3.6.1.4.1.81.15
OBJECT IDENTIFIER    

cl 1.3.6.1.4.1.81.16
OBJECT IDENTIFIER    

bRouter 1.3.6.1.4.1.81.21
OBJECT IDENTIFIER    

lntFddiGroup 1.3.6.1.4.1.81.25
OBJECT IDENTIFIER    

ethAg 1.3.6.1.4.1.81.12.1
OBJECT IDENTIFIER    

ethAgTable 1.3.6.1.4.1.81.12.1.1
Table of attributes which define configuration characteristics for chassis SNMP agents which use Ethernet as in-band management protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthAgEntry

ethAgEntry 1.3.6.1.4.1.81.12.1.1.1
An entry in the table, containing data about a single Ethernet agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  EthAgEntry  

ethAgId 1.3.6.1.4.1.81.12.1.1.1.1
Index which identifies the Ethernet agent for which the current entry provides information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

ethAgPerfBusSelection 1.3.6.1.4.1.81.12.1.1.1.2
Attribute describing the bus attached to the performance data collection hardware on those agent hardware implementations which support configuration management on multi-Ethernet bus enclosures, but performan- ce data collection on a single bus.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ethGroup 1.3.6.1.4.1.81.12.2
OBJECT IDENTIFIER    

ethGroupTable 1.3.6.1.4.1.81.12.2.1
Table of attributes which define configuration characteristics for Ethernet modules.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthGroupEntry

ethGroupEntry 1.3.6.1.4.1.81.12.2.1.1
An entry in the table, containing data about a single Ethernet module (group).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  EthGroupEntry  

ethGroupId 1.3.6.1.4.1.81.12.2.1.1.1
Index which identifies the group inside the chassis for which this entry contains information. Equals the number of the slot by which the group is accessed. This value is never greater than chNumberOfSlots.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

ethGroupFIFO 1.3.6.1.4.1.81.12.2.1.1.2
Value ON of this attribute describes an internal FIFO error sensed by the internal hardware mechanism of a repeater.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethGroup10BTPlus 1.3.6.1.4.1.81.12.2.1.1.3
Value ON of this attribute defines activation of the 10BaseTPlus mode - a proprietary extension of the 10BaseT standard.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethGroupIntPortsRedundancy 1.3.6.1.4.1.81.12.2.1.1.4
Value ON of this attribute defines a redundancy (backup) relationship between internal ports 1 and 2 on a module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethGroupBackboneMode 1.3.6.1.4.1.81.12.2.1.1.5
Value On of this attribute defines Backbone Mode of a sensor. Internal ports are enabled and the information path goes straightly from external port to internal bus, via corresponding internal port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethGroupFOIRLPlusMode 1.3.6.1.4.1.81.12.2.1.1.6
Value On of this attribute defines FOIRL of a sensor. When this attribute has value ON, FOIRL Plus mode is enabled, while value OFF indicates stan- dard FOIRL mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethGroupWrongPortSelection 1.3.6.1.4.1.81.12.2.1.1.7
A value ON of this attribute warns of incorrect selection of enabled ports on sensors which impose restrictions on this configura- tion (e.g. integrated local bridges.)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethGroupBackupBus 1.3.6.1.4.1.81.12.2.1.1.8
Defines the common secondary bus for Ethernet modules with bus redundancy defined at port level.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4  

ethGroupSingleBusMode 1.3.6.1.4.1.81.12.2.1.1.9
Value 'on of this attribute defines bus-star mode for cards supporting this type of configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethGroupSpecificOID 1.3.6.1.4.1.81.12.2.1.1.10
This attribute provides the OID of another group containing additional more specific information regarding this instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

ethGroup10FBPlus 1.3.6.1.4.1.81.12.2.1.1.11
This variable enables/disables 10BaseFB plus mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethGroupMasterClock 1.3.6.1.4.1.81.12.2.1.1.12
This attribute pertains to the SH-E16 chassis and defines the hub in the stack that generates the clock.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethGroupIdleTrx 1.3.6.1.4.1.81.12.2.1.1.13
This attribute is relevant to the LE-120Q/SQ modules and when set to 'off' after port disable terminates also light propagation (for redundancy tests).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethGroupTotalFrames 1.3.6.1.4.1.81.12.2.1.1.15
The total number of frames of valid frame length that have been received on the ports in this group and for which the FCSError and CollisionEvent signals were not asserted. This statistic provides one of the parameters necessary for obtaining the packet error rate. The approximate minimum time for rollover of this counter is 80 hours. This item is a Repeater MIB counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethGroupTotalOctets 1.3.6.1.4.1.81.12.2.1.1.16
The total number of octets contained in the valid frames that have been received on the ports in this group. This counter is the summation of the values of the ethPortReadableOctets counters for all of the ports in the group. This statistic provides an indicator of the total data transferred. The approximate minimum time for rollover of this counter is 58 minutes. This item is a Repeater MIB counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethGroupTotalErrors 1.3.6.1.4.1.81.12.2.1.1.17
The total number of errors which have occurred on all of the ports in this group. This counter is the summation of the values of the ethPortTotalErrors counters for all of the ports in the group. This item is a Repeater MIB counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethGroupBridgeMode 1.3.6.1.4.1.81.12.2.1.1.18
This attribute defines between which buses/ports the IELB bridge is bridging.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bus1Tobus2(3), bus1ToAUIPort(5), bus2ToAUIPort(6), bus1To10BTPort(9), bus2To10BTPort(10), portAUITo10BTPort(12)  

ethGroupBroadcastPkts 1.3.6.1.4.1.81.12.2.1.1.19
The total number of good packets received that were directed to the broadcast address, through this ports group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethGroupMulticastPkts 1.3.6.1.4.1.81.12.2.1.1.20
The total number of good packets received that were directed to a multicast address, through this ports group. Note that this number does not include packets directed to the broadcast address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPort 1.3.6.1.4.1.81.12.3
OBJECT IDENTIFIER    

ethPortTable 1.3.6.1.4.1.81.12.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthPortEntry

ethPortEntry 1.3.6.1.4.1.81.12.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  EthPortEntry  

ethPortGroupId 1.3.6.1.4.1.81.12.3.1.1.1
Id of the group to which the port belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ethPortId 1.3.6.1.4.1.81.12.3.1.1.2
Unique Id of the port in the ethPortTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ethPortFunctionalStatus 1.3.6.1.4.1.81.12.3.1.1.3
The value of this attribute reflects the functional status of synchronous ports. Note that it is not mandatory that all ports support all the enumerated states. ok(1) - fully functional port, transmitting and receiving packets. rld(2) - receive link down condition on the port - Indicates a cable or connector failure detected by the port H/W. localJabber(3) - fault condition indicating that the port emitted jabber (excessive long transmission) tld(4) - transmit link down condition on the port - Indicates a cable or connector failure detected by the H/W of a port connected to the monitored port. remoteJabber(5) - fault condition indicating that remote jabber was sensed at the port. illSeq(6) - fault condition indicating an illegal synchronization sequence at the port. shortCircuit(7) - short-circuit fault condition detected at the port. partitionOrLocalJabber(8) - one of the partition or local jabber (excessive long transmission) was detected at the port of an optical repeater ) - remoteFaultOrLockLoss(9) - one of optical repeater fault conditions, detected by the port H/W. remoteFault(10) - fault condition, detected by an optical port connected to the monitored port. lockLost(11) - optical port H/W fault.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), rld(2), localJabber(3), tld(4), remoteJabber(5), illSeq(6), shortCirc(7), partitionOrLocalJabber(8), remoteFaultOrLockLost(9), remoteFault(10), lockLost(11), notSupported(255)  

ethPortManPart 1.3.6.1.4.1.81.12.3.1.1.4
Setting the value of this attribute to ON activates the manual partition mechanism at the port level. Setting the value of this attribute to OFF cancels the partition mechanism. The segment may reconnect after the reception of 32 packets. Attribute vaild for repeater modules from the LE-10 family.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethPortJabber 1.3.6.1.4.1.81.12.3.1.1.5
Value ON of this attribute reflects jabber transmitted to the port by the hardware of a repeater or transceiver, as a result of collisions detected on the port. Valid for all modules in the LE-10 and LE-15 families.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethPortNoAUILoop 1.3.6.1.4.1.81.12.3.1.1.6
Value ON of this attribute indicates that a No AUI Loop fault condition was detected on an AUI repeater port. Valid for LE-10C family of modu- les.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethPortMJLP 1.3.6.1.4.1.81.12.3.1.1.7
Value ON of this attribute describes an internal MJLP (MAU Jabber Lockup Protection) error sensed by the internal hardware mechanism of a repeater. This mechanism is activated to protect the repeater ports from a jabber condition (excessive long transmission) detected on one of the port. Valid for LE140XTF.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethPortFIFO 1.3.6.1.4.1.81.12.3.1.1.8
Value ON of this attribute describes an internal FIFO error sensed by the internal hardware mechanism of a repeater. Valid for LE140XTF.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethPortAutoPartitionState 1.3.6.1.4.1.81.12.3.1.1.9
The AutoPart condition indicates that the port is currently partitioned by the auto-partition protection mechanism.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER autoPartition(1), notAutoPartition(2), notSupported(255)  

ethPortSQETest 1.3.6.1.4.1.81.12.3.1.1.10
Settable attribute which allows activation of SQE test for integrated transceivers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2), notSupported(255)  

ethPortLastSourceAddr 1.3.6.1.4.1.81.12.3.1.1.11
Ethernet source address of the last readable frame received by this port. The value of this item may be set to 000000 (a string of 6 zeros) by a management console, but not to any other value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

ethPortUserStatus 1.3.6.1.4.1.81.12.3.1.1.12
Attribute defining the connection of a port to a single Ethernet source or to a multi-source (segment or star).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER singleUser(1), multiUser(2), notSupported(255)  

ethPortMainBusSelection 1.3.6.1.4.1.81.12.3.1.1.13
On cards with port-level redundancy, defines the main bus for each port instance as selected by user.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ethPortTraffic 1.3.6.1.4.1.81.12.3.1.1.14
Counter for the number of bits received on this port in frames with legal length information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortFramesReceivedOK 1.3.6.1.4.1.81.12.3.1.1.15
A representation of the total number of frames of legal length that have not been corrupted in transmission. These frames can be encoded and decoded by the commonly available MACs and provide a measure of the network bandwidth being used. The number does not include frames received with frame-too-long, FCS, alignment errors, frames lost due to internal MAC sublayer errors, runts or pygmys.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortRunts 1.3.6.1.4.1.81.12.3.1.1.16
This counter is incremented by one for each CarrierEvent on this port that meets one of the following two conditions. Only one test need be made. a) The ActivityDuration is greater than ShortEventMaxTime and less than ValidPacketMinTime and the CollisionEvent signal is deasserted. b) The OctetCount is less than 64, the ActivityDuration is greater than ShortEventMaxTime and the CollisionEvent signal is deasserted. ValidPacketMinTime is greater than or equal to 552 bit times and less than 565 bit times. An event whose length is greater than 74 bit times but less than 82 bit times shall increment either the shortEvents counter or the runts counter but not both. A CarrierEvent greater than or equal to 552 bit times but less than 565 bit times may or may not be counted as a runt. ValidPacketMinTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Runts usually indicate collision fragments, a normal network event. In certain situations associated with large diameter networks a percentage of collision fragments may exceed ValidPacketMinTime. The approximate minimum time for rollover of this counter is 16 hours. REFERENCE Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aRunts.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortPacketErrors 1.3.6.1.4.1.81.12.3.1.1.17
Counter for the number of frames with errors detected on the port by the agent hardware. This generic port error comprises too long packets, CRC and alignment errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortSpecificOID 1.3.6.1.4.1.81.12.3.1.1.18
This attribute provides the OID of another group containing additional more specific information regarding this instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

ethPortCollisions 1.3.6.1.4.1.81.12.3.1.1.19
This counter is incremented by one for any CarrierEvent signal on any port for which the CollisionEvent signal on this port is also asserted. The approximate minimum time for rollover of this counter is 16 hours. Relevant for MPR and HIMIB modules. REFERENCE Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aCollisions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortPartitions 1.3.6.1.4.1.81.12.3.1.1.20
This counter is incremented by one for each time the repeater has automatically partitioned this port. The conditions that cause port partitioning are specified in the partition state machine in Section 9 [IEEE 802.3 Std]. They are not differentiated here. Relevant for MPR and HIMIB modules. REFERENCE Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aAutoPartitions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortPygmys 1.3.6.1.4.1.81.12.3.1.1.21
The number of pygmys observed on a specified port. The pygmy is a short event. This counter is incremented by one for each CarrierEvent on this port with ActivityDuration less than ShortEventMaxTime. ShortEventMaxTime is greater than 74 bit times and less than 82 bit times. ShortEventMaxTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Note: shortEvents may indicate externally generated noise hits which will cause the repeater to transmit Runts to its other ports, or propagate a collision (which may be late) back to the transmitting DTE and damaged frames to the rest of the network. Implementors may wish to consider selecting the ShortEventMaxTime towards the lower end of the allowed tolerance range to accommodate bit losses suffered through physical channel devices not budgeted for within this standard. The approximate minimum time for rollover of this counter is 16 hours. REFERENCE Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aShortEvents.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortJabberCounter 1.3.6.1.4.1.81.12.3.1.1.22
Counter for the number of local jabbers detected on a specific port (LE-115Q).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortCoupling 1.3.6.1.4.1.81.12.3.1.1.23
Indication of port's coupling method in Ethernet transceiver modules (LE-115Q). The coupling methode can be set on board, using specific jumpers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dc(1), ac(2), notSupported(255)  

ethPortPolarity 1.3.6.1.4.1.81.12.3.1.1.24
This item defines the polarity state of the connection to LE-240XTC and LE-280XT ports. If the wires are crossed, the value is crossed(2), otherwise ok(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), crossed(2), notSupported(255)  

ethPortReadableFrames 1.3.6.1.4.1.81.12.3.1.1.25
This object is the number of frames of valid frame length that have been received on this port. This counter is incremented by one for each frame received on this port whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: IEEE 802.3 Std, 4.4.2.1) and for which the FCSError and CollisionEvent signals are not asserted. This statistic provides one of the parameters necessary for obtaining the packet error rate. The approximate minimum time for rollover of this counter is 80 hours. REFERENCE Reference IEEE 802.3 Rptr Mgt, 19.2.6.2, aReadableFrames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortReadableOctets 1.3.6.1.4.1.81.12.3.1.1.26
This counter is the number of octets contained in valid frames that have been received on this port.It is incremented for each frame received on this port which has been determined to be a readable frame (including FCS octets but excluding framing bits and dribble bits). This statistic provides an indicator of the total data transferred. The approximate minimum time for rollover of this counter is 58 minutes. This object is a Repeater MIB counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortFCSErrors 1.3.6.1.4.1.81.12.3.1.1.27
This counter is incremented by one for each frame received on this port with the FCSError signal asserted and the FramingError and CollisionEvent signals deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). The approximate minimum time for rollover of this counter is 80 hours. This object is a Repeater MIB counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortAlignmentErrors 1.3.6.1.4.1.81.12.3.1.1.28
This counter is incremented by one for each frame received on this port with the FCSError and FramingError signals asserted and CollisionEvent signal deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: IEEE 802.3 Std, 4.4.2.1). The approximate minimum time for rollover of this counter is 80 hours. This object is a Repeater MIB counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortFramesTooLong 1.3.6.1.4.1.81.12.3.1.1.29
This counter is incremented by one for each frame received on this port whose OctetCount is greater than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). The approximate minimum time for rollover of this counter is 61 days. This object is a Repeater MIB counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortLateEvents 1.3.6.1.4.1.81.12.3.1.1.30
This counter is incremented by one for each CarrierEvent on this port in which the CollIn(X) variable transitions to the value SQE (Ref:9.6.6.2, IEEE 802.3 Std) while the ActivityDuration is greater than the LateEventThreshold. Such a CarrierEvent is counted twice, as both a collision and as a lateEvent. The approximate minimum time for rollover of this counter is 81 hours. This object is a Repeater MIB counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortVeryLongEvents 1.3.6.1.4.1.81.12.3.1.1.31
This counter is incremented by one for each CarrierEvent on this port whose ActivityDuration is greater than the MAU Jabber Lockup Protection timer TW3 (Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std). Other counters may be incremented as appropriate. This object is a Repeater MIB counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortDataRateMismatches 1.3.6.1.4.1.81.12.3.1.1.32
This counter is incremented by one for each frame received on this port that meets all of the following conditions: a) The CollisionEvent signal is not asserted. b) The ActivityDuration is greater than ValidPacketMinTime. c) The frequency (data rate) is detectably mismatched from the local transmit frequency. This object is a Repeater MIB counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortTotalErrors 1.3.6.1.4.1.81.12.3.1.1.33
The total number of errors which have occurred on this port. This counter is the summation of the values of other error counters (for the same port), namely: ethPortFCSErrors, ethPortAlignmentErrors, ethPortFrameTooLongs, ethPortShortEvents, ethPortLateEvents, ethPortVeryLongEvents, and ethPortDataRateMismatches. This object is a Repeater MIB counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortSourceAddrChanges 1.3.6.1.4.1.81.12.3.1.1.34
This counter is incremented by one for each time that the last source address of frames entering this port has changed. This may indicate whether a link is connected to a single DTE or another multi-user segment. The approximate minimum time for rollover of this counter is 81 hours. This object is a Repeater MIB counter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortOperStatus 1.3.6.1.4.1.81.12.3.1.1.35
This object indicates the port's operational status. The operational(1) status indicates that the port is enabled and working, even though it might be auto-partitioned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER operational(1), notOperational(2), notSupported(255)  

ethPortBroadcastPkts 1.3.6.1.4.1.81.12.3.1.1.36
The total number of good packets received that were directed to the broadcast address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethPortMulticastPkts 1.3.6.1.4.1.81.12.3.1.1.37
The total number of good packets received that were directed to a multicast address. Note that this number does not include packets directed to the broadcast address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethIntPort 1.3.6.1.4.1.81.12.4
OBJECT IDENTIFIER    

ethIntPortTable 1.3.6.1.4.1.81.12.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthIntPortEntry

ethIntPortEntry 1.3.6.1.4.1.81.12.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  EthIntPortEntry  

ethIntPortGroupId 1.3.6.1.4.1.81.12.4.1.1.1
ID of the group to which the internal port belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

ethIntPortId 1.3.6.1.4.1.81.12.4.1.1.2
ID of the internal port in the ethIntPortTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

ethIntPortPartition 1.3.6.1.4.1.81.12.4.1.1.3
This condition indicates that the internal port is currently partitioned from the bus by the auto-partition protection mechanism.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethIntPortJabber 1.3.6.1.4.1.81.12.4.1.1.4
Value ON of this attribute reflects jabber being transmitted to the bus by the hardware of a repeater, as a result of collisions detected on the internal bus of the enclosure. This situation is similar to MJLP as defined by the Repeater Management standard.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethIntPortBackedUp 1.3.6.1.4.1.81.12.4.1.1.5
Indicates that internal port is part of a redundancy scheme.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

ethBus 1.3.6.1.4.1.81.12.5
OBJECT IDENTIFIER    

ethBusPerfTable 1.3.6.1.4.1.81.12.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthBusPerfEntry

ethBusPerfEntry 1.3.6.1.4.1.81.12.5.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  EthBusPerfEntry  

ethBusPerfAgId 1.3.6.1.4.1.81.12.5.1.1.1
ID of the agent in the ethBusPerfTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

ethBusPerfId 1.3.6.1.4.1.81.12.5.1.1.2
ID of the bus in the ethBusPerfTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

ethBusTrafficBuffer 1.3.6.1.4.1.81.12.5.1.1.3
Record of traffic for the last second with a resolution of 100 msec. The traffic is expressed in percents of the maximum Ethernet traffic and each record contains 10 readings, in the range 1..20, expressed on a log(10) scale ( value = 10*log10(percent) ).
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ethBusTrafficThresh 1.3.6.1.4.1.81.12.5.1.1.4
Traffic threshold value. When exceeded, a trap is send to the management console. Expressed in percents of the maximum Ethernet traffic, in the range 1..20, expressed on a log(10) scale.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ethBusPeakTraffic 1.3.6.1.4.1.81.12.5.1.1.5
Maximal traffic value since last reset of hub or relay. Expressed in per- cents of the maximum Ethernet traffic, in the range 1..20, expressed on log(10) scale. The write access is reserved for resetting the value of the peak.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ethBusTotalCollisions 1.3.6.1.4.1.81.12.5.1.1.6
Counter incremented every time the hub enters a condition caused by simultaneous transmission and detection of external activity on one or more of its ports.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethBusTotalPackets 1.3.6.1.4.1.81.12.5.1.1.7
Counter for number of packets (good and errors) detected on the Ethernet bus.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethBusTotalErrors 1.3.6.1.4.1.81.12.5.1.1.8
Counter for number of errors detected on the Ethernet bus. Does not take into account the collisions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ethBusTraffic 1.3.6.1.4.1.81.12.5.1.1.9
Last traffic reading (sampling time = 100 msec). The traffic is expressed in percents of the maximum Ethernet traffic in the range 1..20, expressed on a log(10) scale ( value = 10*log10(percent) ).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ethBusUtilization 1.3.6.1.4.1.81.12.5.1.1.10
Last traffic reading (sampling time = 100 msec). The traffic is expressed in percents of the maximum Ethernet traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ethBusPeakUtilization 1.3.6.1.4.1.81.12.5.1.1.11
Maximal traffic value since last reset of agent. Expressed in percents of the maximum effective Ethernet traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ethBusThresholdStatus 1.3.6.1.4.1.81.12.5.1.1.12
This item is a bitmap that defines the threshold status of the bus, in relation to the alarmPolicyTable. If the bus is monitored by the agent according to policy number x in the alarmPolicyTable, and the threshold condition has occured, then the bit #x in this item will have the value '1'. Otherwise it will be '0'. For x-186 based agents all bits of this item are '0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

ethBusClockTable 1.3.6.1.4.1.81.12.5.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthBusClockEntry

ethBusClockEntry 1.3.6.1.4.1.81.12.5.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  EthBusClockEntry  

ethBusClockBusId 1.3.6.1.4.1.81.12.5.2.1.1
ID of the bus in the ethBusClockTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

ethBusClockId 1.3.6.1.4.1.81.12.5.2.1.2
ID of the clock in the ethBusClockTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

ethBusClockTestResult 1.3.6.1.4.1.81.12.5.2.1.3
Values clockFailure(2) and busFailure(3) define the faulty status for clock tests. The test is performed by LCL100 module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), clockFailure(2), busFailure(3), notSupported(255)  

feth 1.3.6.1.4.1.81.12.6
OBJECT IDENTIFIER    

fethPort 1.3.6.1.4.1.81.12.6.1
OBJECT IDENTIFIER    

fethPortTable 1.3.6.1.4.1.81.12.6.1.1
Table of descriptive, status, performance and error information about the ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FethPortEntry

fethPortEntry 1.3.6.1.4.1.81.12.6.1.1.1
An entry in the table, containing information, performance and error statistics about a single port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FethPortEntry  

fethPortGroupId 1.3.6.1.4.1.81.12.6.1.1.1.1
Id of the group to which the port belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fethPortId 1.3.6.1.4.1.81.12.6.1.1.1.2
Unique Id of the port in the ethPortTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fethPortFunctionalStatus 1.3.6.1.4.1.81.12.6.1.1.1.3
The value of this attribute reflects the functional status of LANNET 100BaseTX port. Here is the set possible states: ok(1)- fully functional port, transmitting and receiving packets. rld(2) - receive link down (Link Test Failure) condition on the port - indicates a broken connection (cable, connector) detected by the port. rxJabber(3) - fault condition indicating that the port received long packet (jabber) from the line. partition(8) - the port is in partition state. remoteFault(10) - fault condition sensed by the remote port. wrong speed(12) - 10Mbit transmission sensed by the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), rld(2), rxJabber(3), partition(8), remoteFault(10), wrongSpeed(12), notSupported(255)  

fethPortFIFO 1.3.6.1.4.1.81.12.6.1.1.1.4
Value ON of this attribute describes an internal FIFO error sensed by the internal hardware mechanism of a the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

fethPortOperStatus 1.3.6.1.4.1.81.12.6.1.1.1.5
This object indicates the port's operational status. The operational(1) status indicates that the port is enabled and working, even though it might be auto-partitioned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER operational(1), notOperational(2), notSupported(255)  

fethPortAutoPartitionState 1.3.6.1.4.1.81.12.6.1.1.1.6
The AutoPart condition indicates that the port is currently partitioned by the auto-partition protection mechanism.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER autoPartition(1), notAutoPartition(2), notSupported(255)  

fethPortFramesReceived 1.3.6.1.4.1.81.12.6.1.1.1.7
A representation of the total number of frames received by the port from the line. The number includes all frames received even those with RxError or alignment errors or those that had been corrupred in transmission.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortFramesTransmitted 1.3.6.1.4.1.81.12.6.1.1.1.8
A representation of the total number of frames transmitted by the port to the line. The number includes all frames transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortTotalErrors 1.3.6.1.4.1.81.12.6.1.1.1.9
The total number of errors which have occurred on this port. This counter is the summation of the values of other error counters (for the same port), namely: fethPortFCSErrors, fethPortAlignmentErrors, fethPortFrameTooLongs, fethPortShortEvents, fethPortLateEvents, fethPortVeryLongEvents, fethPortDataRateMismatches, For LFE-100 only : fethPortAlignmentErrors, fethPortRxErrors. This counter is redundant in the sense that it is the summation of information already available through other objects. However, it is included specifically because the regular retrieval of this object as a means of tracking the health of a port provides a considerable optimization of network management traffic over the otherwise necessary retrieval of the summed counters. REFERENCE Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortTotalErrors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortFramesTransmittedOK 1.3.6.1.4.1.81.12.6.1.1.1.10
A representation of the total number of frames of legal length that have not been corrupted in transmission that transmitted by the port to the line. These frames can be encoded and decoded by the commonly available MACs. Not supported by LFE1008.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortCollisionFrames 1.3.6.1.4.1.81.12.6.1.1.1.11
This counter is incremented by one for any CarrierEvent signal on any port for which the CollisionEvent signal on this port is also asserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortAlignmentErrors 1.3.6.1.4.1.81.12.6.1.1.1.12
This counter is incremented by one for each frame received on this port with the FCSError and FramingError signals asserted and CollisionEvent signal deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortRxErrors 1.3.6.1.4.1.81.12.6.1.1.1.13
The total number of received frames with error code violation or dose not terminate correctlly.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortReadableFrames 1.3.6.1.4.1.81.12.6.1.1.1.14
This object is the number of frames of valid frame length that have been received on this port. This counter is incremented by one for each frame received on this port whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: IEEE 802.3 Std, 4.4.2.1) and for which the FCSError and CollisionEvent signals are not asserted. This statistic provides one of the parameters necessary for obtaining the packet error rate. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.4, aReadableFrames. Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortReadableFrames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortUpper32ReadableOctets 1.3.6.1.4.1.81.12.6.1.1.1.15
This object is the number of octets contained in valid frames that have been received on this port. This counter is incremented by OctetCount for each frame received on this port which has been determined to be a readable frame (i.e., including FCS octets but excluding framing bits and dribble bits). This statistic provides an indicator of the total data transferred. Note that this counter and fethPortLower32ReadableOctets forms a 64 bits counter. It is provided for those network management protocols that do not support 64 bit counters (e.g. SNMP V1) and the repeater type is 100Mbs. REFERENCE Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortUpper32ReadableOctets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortLower32ReadableOctets 1.3.6.1.4.1.81.12.6.1.1.1.16
This object is the number of octets contained in valid frames that have been received on this port. This counter is incremented by OctetCount for each frame received on this port which has been determined to be a readable frame (i.e., including FCS octets but excluding framing bits and dribble bits). This statistic provides an indicator of the total data transferred. Note that this counter and fethPortUpper32ReadableOctets forms a 64 bits counter. It is provided for those network management protocols that do not support 64 bit counters (e.g. SNMP V1) and the repeater type is 100Mbs. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.5, aReadableOctets. Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortLower32ReadableOctets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortFCSErrors 1.3.6.1.4.1.81.12.6.1.1.1.17
This counter is incremented by one for each frame received on this port with the FCSError signal asserted and the FramingError and CollisionEvent signals deasserted and whose OctetCount is greater than or equal to minFrameSize and less than or equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.6, aFrameCheckSequenceErrors. Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortFCSErrors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortFrameTooLongs 1.3.6.1.4.1.81.12.6.1.1.1.18
This counter is incremented by one for each frame received on this port whose OctetCount is greater than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std). If fethPortFrameTooLongs is incremented then neither the fethPortAlignmentErrors nor the fethPortFCSErrors counter shall be incremented for the frame. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.8, aFramesTooLong. Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortFrameTooLongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortShortEvents 1.3.6.1.4.1.81.12.6.1.1.1.19
This counter is incremented by one for each CarrierEvent on this port with ActivityDuration less than ShortEventMaxTime. ShortEventMaxTime is 84 bits (21 nibbles). Note: shortEvents may indicate externally generated noise hits which will cause the repeater to transmit Runts to its other ports, or propagate a collision (which may be late) back to the transmitting DTE and damaged frames to the rest of the network. Implementors may wish to consider selecting the ShortEventMaxTime towards the lower end of the allowed tolerance range to accommodate bit losses suffered through physical channel devices not budgeted for within this standard. Note also that clause 27 repeaters do not perform fragment extension as clause 9 repeater does. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.9, aShortEvents. Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortShortEvents.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortRunts 1.3.6.1.4.1.81.12.6.1.1.1.20
This counter is incremented by one for each CarrierEvent on this port that meets one of the following two conditions. Only one test need be made. a) The ActivityDuration is greater than ShortEventMaxTime and less than validPacketMinTime and the CollisionEvent signal is deasserted. b) The OctetCount is less than 64, the ActivityDuration is greater than ShortEventMaxTime and the CollisionEvent signal is deasserted. ValidPacketMinTime is greater than or equal to 552 bit times and less than 565 bit times. ValidPacketMinTime has tolerances included to provide for circuit losses between a conformance test point at the AUI and the measurement point within the state machine. Runts usually indicate collision fragments, a normal network event. In certain situations associated with large diameter networks a percentage of collision fragments may exceed ValidPacketMinTime. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.1.3.10, aRunts. Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortRunts.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortLateEvents 1.3.6.1.4.1.81.12.6.1.1.1.21
This counter is incremented by one on entering the Collision Count Increment state of the partition state diagram (fig 27-8) while the ActivityDuration is greater than the LateEvent- Threshold. Such a CarrierEvent is counted twice, as both collision and a late event. The LateEventThreshold is greater than 480 bit times and less than 565 bit times. LateEventThreshold has tolerances included to permit an implementation to build a single threshold to serve as both the LateEventThreshold and ValidPacketMinTime threshold. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.12, aLateEvents. Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortLateEvents.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortVeryLongEvents 1.3.6.1.4.1.81.12.6.1.1.1.22
This counter is incremented by one on entry to the Rx Jabber state of the receiver timer state diagram (fig 27-7). Other counters may be incremented as appropriate. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.13, aVeryLongEvents. Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortVeryLongEvents.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortDataRateMismatches 1.3.6.1.4.1.81.12.6.1.1.1.23
This counter is incremented by one for each frame received on this port that meets all of the following conditions: a) the Collision Count Increment state of the partition state diagram (fig 27-8) has not been entered. b) The ActivityDuration is greater than ValidPacketMinTime. c) The frequency (data rate) is detectably mismatched from the local transmit frequency. The exact degree of mismatch is vendor specific and is to be defined by the vendor for conformance testing. When this event occurs, other counters whose increment conditions were satisfied may or may not also be incremented, at the implementor's discretion. Whether or not the repeater was able to maintain data integrity is beyond the scope of this standard. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.14, aDataRateMismatches. Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortDataRateMismatches.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortAutoPartitions 1.3.6.1.4.1.81.12.6.1.1.1.24
This counter is incremented by one on entry to the Partition Wait state of the partition state diagram (fig 27-8). REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.14, aAutoPartitions. Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortAutoPartitions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortSymbolErrors 1.3.6.1.4.1.81.12.6.1.1.1.25
This counter is incremented by one each time when valid length packet was received at the port and there was at least one occurrence of an invalid data symbol. This can increment only once per valid carrier event. A collision presence at any port of the repeater containing port N, will not cause this attribute to increment. This Counter has a maximum increment rate of 160,000 counts per second for 100Mb/s implementation. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.17, aSymbolErrorDuringPacket. Reference IETF 100Base-T Repeater MIB, rptr100MonitorPortSymbolErrors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortLastSourceAddress 1.3.6.1.4.1.81.12.6.1.1.1.26
This object is the SourceAddress of the last readable frame (i.e., counted by fethPortReadableFrames) received by this port. If no frames have been received by this port since the agent began monitoring the port activity, the agent shall return a string of length zero. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.18, aLastSourceAddress. Reference IETF 100Base-T Repeater MIB, rptr100AddrTrackLastSourceAddress.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..6)  

fethPortSourceAddrChanges 1.3.6.1.4.1.81.12.6.1.1.1.27
This counter is incremented by one for each time that the fethPortLastSourceAddress attribute for this port has changed. This may indicate whether a link is connected to a single DTE or another multi-user segment. The approximate minimum time for rollover of this counter is 8 hours. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.3.1.19, aSourceAddressChanges. Reference IETF 100Base-T Repeater MIB, rptr100AddrTrackSourceAddrChanges.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortMode 1.3.6.1.4.1.81.12.6.1.1.1.28
The mode of the port. halfDuplex(1)- standard mode, usually for segments. fullDuplex(2)- standard mode, usually for servers. fullDuplexAndFlowControl(3)- the module transmits Flow Control symbols to the line between two HUBs in order to control the flow of data. fullDuplexAndISL(4)- the module transmits to the line a control-word from the HSB, in order to transfer VLANs and Priority to another HUB ( ISL=Inter Switch Link). fullDuplexAndFlowControlAndISL(5)- FDX with both Flow Control and ISL modes. It is the user's responsibility to set both modules connected to the line, to the same mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER halfDuplex(1), fullDuplex(2), fullDuplexAndFlowControl(3), fullDuplexAndISL(4), fullDuplexAndFlowControlAndISL(5), notSupported(255)  

fethPortLinkRedundancyMode 1.3.6.1.4.1.81.12.6.1.1.1.29
This item is relevant for modules which include redundant links. This item enables/disables the Redundancy mechanism. When enabled, the Sensor will alternately switch between the main and secondary ports/links, upon a predefined failure indication. See also the fethPortEnablePHY item.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), notSupported(255)  

fethPortLinkRedundancyStatus 1.3.6.1.4.1.81.12.6.1.1.1.30
This item is relevant for ports which includes redundant links. This item indicates which of the links is active. Default value=firstLinkActive(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER firstLinkActive(1), secondLinkActive(2), notSupported(255)  

fethPortDormantLinkFunctionalStatus 1.3.6.1.4.1.81.12.6.1.1.1.31
The value of this attribute reflects the functionality status of the dormant link, in modules such as LEB-200, which have link redundancy capability. Note that the Main Link functionality status is still reflected by the fethPortFunctionalStatus item as usual.. Default value=ok(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), rld(2), remoteFault(10), notSupported(255)  

fethPortUpper32TransmittedOctets 1.3.6.1.4.1.81.12.6.1.1.1.32
This object is the number of octets contained in valid frames that have been transmitted on this port. This counter is incremented by OctetCount for each frame transmitted on this port which has not been encountered with a collision event. This statistic provides an indicator of the total data transferred. Note that this counter and fethPortLower32TransmittedOctets forms a 64 bits counter. It is provided for those network management protocols that do not support 64 bit counters (e.g. SNMP V1) and the repeater type is 100Mbs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortLower32TransmittedOctets 1.3.6.1.4.1.81.12.6.1.1.1.33
This object is the number of octets contained in valid frames that have been transmitted on this port.This counter is incremented by OctetCount for each frame transmitted on this port which has not been encountered with a collision event. This statistic provides an indicator of the total data transferred. Note that this counter and fethPortUpper32TransmittedOctets forms a 64 bits counter. It is provided for those network management protocols that do not support 64 bit counters (e.g. SNMP V1) and the repeater type is 100Mbs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortBroadcastReceivedFrames 1.3.6.1.4.1.81.12.6.1.1.1.34
This object is the number of Broadcast readable frames that have been Received on this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortMulticastReceivedFrames 1.3.6.1.4.1.81.12.6.1.1.1.35
This object is the number of Multicast readable (good) frames that have been Received on this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethPortEnablePHY 1.3.6.1.4.1.81.12.6.1.1.1.36
This item is relevant for ports which include redundant links (such as LEB200). This item is not valid and has no effect when the fethPortLinkRedundancyMode=enable(1). This item determines and indicates the active PHY in case that fethPortLinkRedundancyMode is set to disable(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enPHY1(1), enPHY2(2), notSupported(255)  

fethGroup 1.3.6.1.4.1.81.12.6.2
OBJECT IDENTIFIER    

fethGroupTable 1.3.6.1.4.1.81.12.6.2.1
Table of descriptive, status, performance and error information about the groups of fast ethernet ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FethGroupEntry

fethGroupEntry 1.3.6.1.4.1.81.12.6.2.1.1
An entry in the table, containing information, total performance and error statistics for a single group of ports. Regular retrieval of the information in this table provides a means of tracking the performance and health of the networked devices attached to this group's ports. The counters in this table are redundant in the sense that they are the summations of information already available through other objects. However, these sums provide a considerable optimization of network management traffic over the otherwise necessary retrieval of the individual counters included in each sum.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  FethGroupEntry  

fethGroupId 1.3.6.1.4.1.81.12.6.2.1.1.1
This object identifies the group within the repeater for which this entry contains information. This value is never greater than fethRepeaterGroupCapacity. REFERENCE Reference IEEE Draft Std 802.3u/D4 Rptr Mgt, 30.4.2.1.1, aGroupID. Reference IETF 100Base-T Repeater MIB, rptr100GroupIndex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

fethGroupOperStatus 1.3.6.1.4.1.81.12.6.2.1.1.2
An object that indicates the operational status of the group. A status of notPresent(4) indicates that the group is temporarily or permanently physically and/or logically not a part of the repeater (Stand Alone). A status of operational(2) indicates that the group is functioning, and a status of malfunctioning(3) indicates that the group is malfunctioning in some way (see fethRepeaterOperStatus). REFERENCE Reference IETF 100Base-T Repeater MIB, rptr100GroupOperStatus.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), operational(2), malfunctioning(3), notPresent(4), underTest(5), resetInProgress(6)  

fethGroupUtilization 1.3.6.1.4.1.81.12.6.2.1.1.3
Utilization of the network, expressed in percentage of the maximum traffic possible ( 100Mbps)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

fethGroupTotalFrames 1.3.6.1.4.1.81.12.6.2.1.1.4
The total number of frames of valid frame length that have been received on the ports in this group and for which the FCSError and CollisionEvent signals were not asserted. This counter is the summation of the values of the fethPortReadableFrames counters for all of the ports in the group. This statistic provides one of the parameters necessary for obtaining the packet error rate. REFERENCE Reference IETF 100Base-T Repeater MIB, rptr100MonitorGroupTotalFrames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethGroupUpper32TotalOctets 1.3.6.1.4.1.81.12.6.2.1.1.5
The total number of octets contained in the valid frames that have been received on the ports in this group. This counter is the summation of the values of the fethPortReadableOctets counters for all of the ports in the group. This statistic provides an indicator of the total data transferred. Note that this counter and fethGroupLower32TotalOctets forms a 64 bits counter. It is provided for those network management protocols that do not support 64 bit counters (e.g. SNMP V1) and the repeater type is 100Mbs. REFERENCE Reference IETF 100Base-T Repeater MIB, rptr100MonitorGroupUpper32TotalOctets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethGroupLower32TotalOctets 1.3.6.1.4.1.81.12.6.2.1.1.6
The total number of octets contained in the valid frames that have been received on the ports in this group. This counter is the summation of the values of the fethPortReadableOctets counters for all of the ports in the group. This statistic provides an indicator of the total data transferred. Note that this counter and fethGroupUpper32TotalOctets forms a 64 bits counter. It is provided for those network management protocols that do not support 64 bit counters (e.g. SNMP V1) and the repeater type is 100Mbs. REFERENCE Reference IETF 100Base-T Repeater MIB, rptr100MonitorGroupLower32TotalOctets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethGroupTotalErrors 1.3.6.1.4.1.81.12.6.2.1.1.7
The total number of errors which have occurred on all of the ports in this group. This counter is the summation of the values of the fethPortTotalErrors counters for all of the ports in the group. REFERENCE Reference IETF 100Base-T Repeater MIB, rptr100MonitorGroupTotalErrors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

fethGroupFefiEnable 1.3.6.1.4.1.81.12.6.2.1.1.8
This item enables\disables the FEFI mechanism of the PHY on the module. It enables\disables both the transmission and the recognition of FEFI signals . This item is used only in modules that support 100BaseFx.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), notSupported(255)  

tokRing 1.3.6.1.4.1.81.13.1
OBJECT IDENTIFIER    

tokRingTable 1.3.6.1.4.1.81.13.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TokRingEntry

tokRingEntry 1.3.6.1.4.1.81.13.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TokRingEntry  

tokRingAgId 1.3.6.1.4.1.81.13.1.1.1.1
ID of the agent to which the ring belongs in the tokRingTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

tokRingId 1.3.6.1.4.1.81.13.1.1.1.2
ID of the ring in the tokRingTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

tokRingLeftSlot 1.3.6.1.4.1.81.13.1.1.1.3
Slot number of the left-most slot of the ring. In the token ring stackable hub, 'Left' should be read as 'Up'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

tokRingRightSlot 1.3.6.1.4.1.81.13.1.1.1.4
Slot number of the right-most slot of the ring that has a lobe port. In the token ring stackable hub, 'Right' should be read as 'Down'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

tokRingTrafficBuffer 1.3.6.1.4.1.81.13.1.1.1.5
Record of traffic for the last second with a resolution of 100 msec. The traffic is expressed in percents of the maximum effective TR traffic (token messages are excluded) and each record contains 10 readings, in range 1..20 on log(10) scale.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING  

tokRingTrafficThresh 1.3.6.1.4.1.81.13.1.1.1.6
Traffic threshold value. When exceeded, a trap is send to the management console. Expressed in percents of the maximum effective TR traffic (token messages are excluded) in the range 1..20 on log(10) scale.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

tokRingPeakTraffic 1.3.6.1.4.1.81.13.1.1.1.7
Maximal traffic value since last reset of agent. Expressed in percents of the maximum effective TR traffic (token messages are excluded), in the range 1..20 on log(10) scale. The write access is reserved for resetting the value of the peak.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

tokRingNumberOfStations 1.3.6.1.4.1.81.13.1.1.1.8
Number of Token Ring stations (controllers) detected on the ring. The TR controller of the agent card is included in this count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tokRingConfiguration 1.3.6.1.4.1.81.13.1.1.1.9
Configuration attribute describing the list of physical addresses detected on the Token Ring. Coded in internal application format.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

tokRingBeaconing 1.3.6.1.4.1.81.13.1.1.1.10
This attribute indicates if a beaconing condition is currently detected on the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokRingBeaconingStation 1.3.6.1.4.1.81.13.1.1.1.11
The MAC address of the last station which was detected as sending Beaconing MAC frames on the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

tokRingStationsMatch 1.3.6.1.4.1.81.13.1.1.1.12
This attribute indicates matching between the number of stations detected on the ring between the current agent and the next agent on Up Stream sense and the number of connected lobe ports.Used by the port address correlation mechanism.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), partial(3), notSupported(255)  

tokRingTraffic 1.3.6.1.4.1.81.13.1.1.1.13
Last traffic reading (sampling time = 100 msec). The traffic is expressed in percents of the maximum Ethernet traffic in the range 1..20, expressed on a log(10) scale ( value = 10*log10(percent) ).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tokRingSecurityMethod 1.3.6.1.4.1.81.13.1.1.1.14
Security scheme selected by the user. perPort(1) indicates that secure addresses are defined for each secured token ring port. perRing(2) indicates that a common set of secure addresses will be allowed for the whole ring. disabled(3) - no security method is applied on this ring.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER perPort(1), perRing(2), disabled(3), notSupported(255)  

tokRingSecurityPolicy 1.3.6.1.4.1.81.13.1.1.1.15
Security policy (trap only or trap and disconnect) selected for the ring. Coded in internal format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

tokRingSecureAddr 1.3.6.1.4.1.81.13.1.1.1.16
Secure addresses assigned to the ring. Coded in internal format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

tokRingLastViolation 1.3.6.1.4.1.81.13.1.1.1.17
MAC address of a last detected intruder.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

tokRingUtilization 1.3.6.1.4.1.81.13.1.1.1.18
Last traffic reading (sampling time = 100 msec). The traffic is expressed in percents of the maximum Token Ring traffic.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tokRingPeakUtilization 1.3.6.1.4.1.81.13.1.1.1.19
Maximal traffic value since last reset of agent. Expressed in percents of the maximum effective TR traffic (token messages are excluded).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tokRingBeaconingResolution 1.3.6.1.4.1.81.13.1.1.1.20
This parameter enables or disables the beaconing resolution.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), notSupported(255)  

tokRingThresholdStatus 1.3.6.1.4.1.81.13.1.1.1.21
This item is a bitmap that defines the threshold status of the ring, in relation to the alarmPolicyTable. If the ring is monitored by the agent according to policy number x in the alarmPolicyTable, and the threshold condition has occured, then the bit #x in this item will have the value '1'. Otherwise it will be '0'. For x-186 based agents all bits of this item are '0'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(4)  

tokRingActiveMonitor 1.3.6.1.4.1.81.13.1.1.1.22
The MAC Address of the station functioning as Active Monitor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

tokGroup 1.3.6.1.4.1.81.13.2
OBJECT IDENTIFIER    

tokGroupTable 1.3.6.1.4.1.81.13.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TokGroupEntry

tokGroupEntry 1.3.6.1.4.1.81.13.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TokGroupEntry  

tokGroupId 1.3.6.1.4.1.81.13.2.1.1.1
Number of the slot in which the group is installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

tokGroupAutoRightLoop 1.3.6.1.4.1.81.13.2.1.1.2
Value ON of this attribute signifies that a hardware loop was automatically created on a Token Ring module which does not sense the existence of another token ring group on the right hand side. In the token ring stackable hub, 'Right' should be read as 'Down'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokGroupAutoLeftLoop 1.3.6.1.4.1.81.13.2.1.1.3
Value ON of this attribute signifies that a hardware loop was automatically created on a Token Ring module which does not sense the existence of another token ring group on the left hand side. In the token ring stackable hub, 'Left' should be read as 'Up'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokGroupManRightLoop 1.3.6.1.4.1.81.13.2.1.1.4
Setting this attribute to ON signifies a command to the hardware to create a loop on the Token Ring module which isolates the ring from the right hand side. In the token ring stackable hub, 'Right' should be read as 'Down'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokGroupManLeftLoop 1.3.6.1.4.1.81.13.2.1.1.5
Setting this attribute to ON signifies a command to the hardware to create a loop on the Token Ring module which isolates the ring from the left hand side. In the token ring stackable hub, 'Left' should be read as 'Up'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokGroupRightNeighbor 1.3.6.1.4.1.81.13.2.1.1.6
Attribute defining the existence of a neighbor another token ring group on the right hand side of the module. In the token ring stackable hub, 'Right' should be read as 'Down'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exist(1), notExist(2)  

tokGroupLeftNeighbor 1.3.6.1.4.1.81.13.2.1.1.7
Attribute defining the existence of a neighbor another token ring group on the left hand side of the module. In the token ring stackable hub, 'Left' should be read as 'Up'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exist(1), notExist(2)  

tokGroupIOMode 1.3.6.1.4.1.81.13.2.1.1.8
Attribute defining the I/O mode (single, dual-ring-in, dual-ring-out) Lobe, Internal Repeater or Star) of a module from the the LTR-IO family.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER single(1), dualRingIn(2), dualRingOut(3), illegalMode(4), lobe(5), intRepeater(6), star(7), starAndRingOut(8), starAndRI(10), starAndSingle(11), starAndIntRepeater(12), notSupported(255)  

tokGroupBridgeMode 1.3.6.1.4.1.81.13.2.1.1.9
Attribute describing the operational mode of the bridge. For ITLB the following modes are defined: - Mode A: First channel connected to an external ring (RI,RO connectors) and second channel connected to an internal ring; - Mode B: First channel connected to an external ring by a DTE connector and second channel connected to an internal ring; - Mode C: First channel connected to an internal left ring and second channel connected to an internal right ring.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER modeA(1), modeB(2), modeC(3), notSupported(255)  

tokGroupManLinkLoop 1.3.6.1.4.1.81.13.2.1.1.10
Setting the value of this attribute to ON instructs the hardware of a Token Ring repeater module to close the loop in the direction of the external connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokGroupManBusLoop 1.3.6.1.4.1.81.13.2.1.1.11
Setting the value of this attribute to ON instructs the hardware of a Token Ring repeater module to close the loop in the direction of the internal bus.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokGroupAutoLinkLoop 1.3.6.1.4.1.81.13.2.1.1.12
Value ON of this attribute signifies that a hardware loop has been auto- matically closed by the hardwar of the Token Ring repeater as a result of problems on the external link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokGroupAutoBusLoop 1.3.6.1.4.1.81.13.2.1.1.13
Value ON of this attribute signifies that a hardware loop has been auto- matically closed by the hardware of the Token Ring repeater as a result of problems on the internal bus.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokGroupSpecificOID 1.3.6.1.4.1.81.13.2.1.1.14
This attribute provides the OID of another group containing additional more specific information regarding this instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

tokGroupStarSpeedDetect 1.3.6.1.4.1.81.13.2.1.1.15
This attribute enables the speed detection mechanism for the ports which are in star mode
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokGroupLobeSpeedDetect 1.3.6.1.4.1.81.13.2.1.1.16
This attribute enables the speed detection mechanism for all ports which are in Lobe mode, at module level.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokGroupLSTBeaconing 1.3.6.1.4.1.81.13.2.1.1.17
This item is for LST168 only. The ring is in beaconning state. Value 'on' informs on beacon fault when the number of consecutive beacon frames is above BeaconThreshold.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokGroupLSTBeaconThresh 1.3.6.1.4.1.81.13.2.1.1.18
This item is for LST168 only.Threshold for the number of consecutive beacon frames in the ring, above which a beaconning fault is alerted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..255  

tokGroupRingTable 1.3.6.1.4.1.81.13.2.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TokGroupRingEntry

tokGroupRingEntry 1.3.6.1.4.1.81.13.2.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TokGroupRingEntry  

tokGroupRingGroupId 1.3.6.1.4.1.81.13.2.2.1.1
ID of the group to which the ring belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

tokGroupRingId 1.3.6.1.4.1.81.13.2.2.1.2
ID of the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

tokGroupRingSpeed 1.3.6.1.4.1.81.13.2.2.1.3
Attribute describing the bandwidth of the ring.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), oneMegabit(2), fourMegabit(3), sixteenMegabit(4), sixteenMgbEarly(5)  

tokGroupRingInserted 1.3.6.1.4.1.81.13.2.2.1.4
Indicates that the bridge interface has inserted itself into the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notInserted(1), inserted(2), notSupported(255)  

tokGroupRingStatus 1.3.6.1.4.1.81.13.2.2.1.5
This item sets the connection of a TR controller to one of its possible connections, identified by the index of this row, for modules with a multiple interface controller (for example ITRP).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), notSupported(255)  

tokPort 1.3.6.1.4.1.81.13.3
OBJECT IDENTIFIER    

tokPortTable 1.3.6.1.4.1.81.13.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TokPortEntry

tokPortEntry 1.3.6.1.4.1.81.13.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TokPortEntry  

tokPortGroupId 1.3.6.1.4.1.81.13.3.1.1.1
ID of the group to which the token ring port belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

tokPortId 1.3.6.1.4.1.81.13.3.1.1.2
ID of the port in the tokPortTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

tokPortBypass 1.3.6.1.4.1.81.13.3.1.1.3
Setting the value of this attribute to ON causes the by- passing of the TokenRing port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokPortConnected 1.3.6.1.4.1.81.13.3.1.1.4
Attribute which describes the connection status of a Token Ring port (inclusion of the Token Ring controller in the ring).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER connected(1), notConnected(2), notSupported(255)  

tokPortTCP 1.3.6.1.4.1.81.13.3.1.1.5
Setting the value of this attribute to ON causes the activation of the cable-fault detection mechanism.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokPortCableFault 1.3.6.1.4.1.81.13.3.1.1.6
Value ON of this attribute signifies the detection of a cable-fault on this specific Token Ring port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokPortFunctionalStatus 1.3.6.1.4.1.81.13.3.1.1.7
The value of this attribute reflects the functional status of Token Ring ports. Note that it is not mandatory that a certain port support all the enumerated states. Here is the lest of the possible states: ok(1) - fully functional port, transmitting and receiving packets. rld(2) - receive link down condition on the port. tld(4) - transmit link down condition on the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), rld(2), tld(4), notSupported(255)  

tokPortLastSourceAddr 1.3.6.1.4.1.81.13.3.1.1.8
MAC source address of the last readable frame received by this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

tokPortSpecificOID 1.3.6.1.4.1.81.13.3.1.1.9
This attribute provides the OID of another group containing additional more specific information regarding this instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

tokPortRingSpeedError 1.3.6.1.4.1.81.13.3.1.1.10
This attribute is set to 'on' when the station tries to enter the ring with a speed different from the speed of the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokPortSpeedDetect 1.3.6.1.4.1.81.13.3.1.1.11
This attribute enables the speed detection mechanism on a port level.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokPortRingId 1.3.6.1.4.1.81.13.3.1.1.12
Unique identifier of the ring/ring segment to which a specific port is connected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tokPortMapping 1.3.6.1.4.1.81.13.3.1.1.13
This attribute enables/disables participation of the selected port in port-to-address correlation algorithm. Default value is on(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

tokRingStation 1.3.6.1.4.1.81.13.4
OBJECT IDENTIFIER    

tokRingStationTable 1.3.6.1.4.1.81.13.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TokRingStationEntry

tokRingStationEntry 1.3.6.1.4.1.81.13.4.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TokRingStationEntry  

tokRingStationRingId 1.3.6.1.4.1.81.13.4.1.1.1
ID of the ring in the in which the station is inserted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

tokRingStationMAC 1.3.6.1.4.1.81.13.4.1.1.2
This item defines the MAC address (in token ring format) of the station connected to the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

tokRingStationLineErrors 1.3.6.1.4.1.81.13.4.1.1.3
This counter is incremented when a frame or token is copied or repeated by a station, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tokRingStationInternalErrors 1.3.6.1.4.1.81.13.4.1.1.4
This counter is incremented when a station recognizes an internal error. Internal errors are detected by the adapter's hardware and/or firmware. They usually cause the detecting adapter to remove itself from the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tokRingStationBurstErrors 1.3.6.1.4.1.81.13.4.1.1.5
This counter is incremented when a station detects the absence of transitions for five half-bit timers (burst-five error).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tokRingStationACErrors 1.3.6.1.4.1.81.13.4.1.1.6
This counter is incremented when a station receives an AMP or SMP frame in which A is equal to C is equal to 0, and then receives another SMP frame with A is equal to C is equal to 0 without first receiving an AMP frame. It denotes a station that cannot set the AC bits properly.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tokRingStationAbortsTrans 1.3.6.1.4.1.81.13.4.1.1.7
This counter is incremented when a station transmits an abort delimiter while transmitting.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tokRingStationLostFrames 1.3.6.1.4.1.81.13.4.1.1.8
This counter is incremented when a station is transmitting and its TRR timer expires. This condition denotes a condition where a transmitting station in strip mode does not receive the trailer of the frame before the TRR timer goes off.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tokRingStationReceiveCongErrors 1.3.6.1.4.1.81.13.4.1.1.9
This counter is incremented when a station recognizes a frame addressed to its specific address, but has no available buffer space indicating that the station is congested.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tokRingStationFramesCopied 1.3.6.1.4.1.81.13.4.1.1.10
This counter is incremented when a station recognizes a frame addressed to its specific address and detects that the FS field A bits are set to 1 indicating a possible line hit or duplicate address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tokRingStationFrequencyErrors 1.3.6.1.4.1.81.13.4.1.1.11
The number of times the interface has detected that the frequency of the incoming signal differs from the expected frequency by more than that specified by the IEEE 802.5 standard.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tokRingStationTokenErrors 1.3.6.1.4.1.81.13.4.1.1.12
This counter is incremented when a station acting as the active monitor recognizes an error condition that needs a token transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tokRingStationTotalErrors 1.3.6.1.4.1.81.13.4.1.1.13
This counter is the sum of all REM counters for this station, i.e.: LineErrors, InternalErrors, BurstErrors, ACErrors, AbortsTrans, LostFrames, FrameCopiedErrors, ReceiveCongestionsErrors, FrequencyErrors, TokenErrors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tokRingStationFunctionalType 1.3.6.1.4.1.81.13.4.1.1.14
The function of the concerned station in the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ringStation(1), agent(2), bridge(3), netbios(4), ringParameterServer(5), ringErrorMonitor(6), lanManager(7), activeMonitor(8), other(9)  

tokIntPort 1.3.6.1.4.1.81.13.5
OBJECT IDENTIFIER    

tokIntPortTable 1.3.6.1.4.1.81.13.5.1
Table of configuration attributes for items specific to token ring internal ports, which can not be addressed via the genIntPort group.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TokIntPortEntry

tokIntPortEntry 1.3.6.1.4.1.81.13.5.1.1
An entry in the table, containing data about a single port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TokIntPortEntry  

tokIntPortGroupId 1.3.6.1.4.1.81.13.5.1.1.1
Index which identifies the group inside the hub for which this entry contains information. Equals the number of the slot by which the group containing the internal port is accessed. This value is never greater than chNumberOfSlots.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

tokIntPortId 1.3.6.1.4.1.81.13.5.1.1.2
Index which identifies the internal port inside the group for which this entry contains information. This value is never greater than genGroupNumberOfIntPorts of the group to which the port belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

tokIntPortLeftNeighbor 1.3.6.1.4.1.81.13.5.1.1.3
Attribute defining the existence of another token ring group to the left hand side of the module, on the TR bus to which this intrnal port is connected. The value bypass is reported when the controller is not connected to the bus.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exist(1), notExist(2), bypass(3)  

tokIntPortRightNeighbor 1.3.6.1.4.1.81.13.5.1.1.4
Attribute defining the existence of another token ring group to the left hand side of the module, on the TR bus to which this intrnal port is connected. The value bypass is reported when the controller is not connected to the bus.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exist(1), notExist(2), bypass(3)  

tokIntPortManLeftLoop 1.3.6.1.4.1.81.13.5.1.1.5
Setting this attribute to on signifies a command to the hardware to create a loop to the left of the module, on the bus to which this internal port is connected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

tokIntPortManRightLoop 1.3.6.1.4.1.81.13.5.1.1.6
Setting this attribute to on signifies a command to the hardware to create a loop to the left of the module, on the bus to which this internal port is connected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

tokIntPortAutoLeftLoop 1.3.6.1.4.1.81.13.5.1.1.7
Value 'on' of this attribute signifies that a left hardware loop was created on the Token Ring bus to which this internal port is connected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

tokIntPortAutoRightLoop 1.3.6.1.4.1.81.13.5.1.1.8
Value 'on' of this attribute signifies that a right hardware loop was created on the Token Ring bus to which this internal port is connected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

tsGroup 1.3.6.1.4.1.81.14.1
OBJECT IDENTIFIER    

tsGroupTable 1.3.6.1.4.1.81.14.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TsGroupEntry

tsGroupEntry 1.3.6.1.4.1.81.14.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TsGroupEntry  

tsGroupId 1.3.6.1.4.1.81.14.1.1.1.1
Number of the slot in which the group is installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

tsGroupLATStatus 1.3.6.1.4.1.81.14.1.1.1.2
Value ON of this attribute means that LAT protocol is Enabled on the Ethernet module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

tsGroupOperationMode 1.3.6.1.4.1.81.14.1.1.1.3
This attribute describes the operation mode of the module in a multiprocessor configuration sensor, as reported by interprocessors communication.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER diagnostics(1), diagnosticsFailure(2), loading(3), loadingFailure(4), operational(5)  

ltalkPort 1.3.6.1.4.1.81.15.1
OBJECT IDENTIFIER    

ltalkPortTable 1.3.6.1.4.1.81.15.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LtalkPortEntry

ltalkPortEntry 1.3.6.1.4.1.81.15.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LtalkPortEntry  

ltalkPortGroupId 1.3.6.1.4.1.81.15.1.1.1.1
Number of the group to which the port belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

ltalkPortId 1.3.6.1.4.1.81.15.1.1.1.2
ID of the port in the ltalkPortTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

ltalkPortTest 1.3.6.1.4.1.81.15.1.1.1.3
A value ON of this attribute indicates that a port test should be performed upon the port defined by the attribute instance.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

ltalkPortTestResult 1.3.6.1.4.1.81.15.1.1.1.4
Indicates the result of a port test performed on this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), faulty(2)  

ltalkPortJam 1.3.6.1.4.1.81.15.1.1.1.5
An ON value of this attribute indicates a Jam error on the specific port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

clGroup 1.3.6.1.4.1.81.16.1
OBJECT IDENTIFIER    

clGroupTable 1.3.6.1.4.1.81.16.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ClGroupEntry

clGroupEntry 1.3.6.1.4.1.81.16.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ClGroupEntry  

clGroupId 1.3.6.1.4.1.81.16.1.1.1.1
Number of the slot in which the group is installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

clGroupClockRedundancy 1.3.6.1.4.1.81.16.1.1.1.2
Value ON of this attribute defines a redundancy (backup) relationship between the internal and external clocks on the LCL100 module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

clGroupMainClock 1.3.6.1.4.1.81.16.1.1.1.3
Value of this attribute is an index into clPortTable, and defines the clock that should operate or a main clock in redundancy scheme. Serves as 'Clock selection' switch on the card.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

clGroupTestClocks 1.3.6.1.4.1.81.16.1.1.1.4
A value ON of this attribute indicates that a test should be performed on all clock ports.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

clPort 1.3.6.1.4.1.81.16.2
OBJECT IDENTIFIER    

clPortTable 1.3.6.1.4.1.81.16.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ClPortEntry

clPortEntry 1.3.6.1.4.1.81.16.2.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ClPortEntry  

clPortGroupId 1.3.6.1.4.1.81.16.2.1.1.1
Number of the group to which the port belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

clPortId 1.3.6.1.4.1.81.16.2.1.1.2
ID of the port in the clPortTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

clPortFunctionalStatus 1.3.6.1.4.1.81.16.2.1.1.3
Indicates whether the clock is faulty or not.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), faulty(2)  

iwb 1.3.6.1.4.1.81.21.1
OBJECT IDENTIFIER    

iwr 1.3.6.1.4.1.81.21.2
OBJECT IDENTIFIER    

itr 1.3.6.1.4.1.81.21.3
OBJECT IDENTIFIER    

iwrGroupTable 1.3.6.1.4.1.81.21.2.1
Attributes pertaining to the integrated router module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IwrGroupEntry

iwrGroupEntry 1.3.6.1.4.1.81.21.2.1.1
An entry in the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IwrGroupEntry  

iwrGroupId 1.3.6.1.4.1.81.21.2.1.1.1
Slot number in which the module is located.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iwrOperState 1.3.6.1.4.1.81.21.2.1.1.2
One of the possible states of the module. run(1) - indicates a successful completion of the boot and self test procedure. boot(2) - indicates that the module is performing the boot and self-test procedure. fail(3) - indicates an unsuccessful completion of the boot and self-test procedure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER run(1), boot(2), fail(3)  

iwrPMState 1.3.6.1.4.1.81.21.2.1.1.3
The state of the Processor Module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), fail(2)  

iwrIOMState 1.3.6.1.4.1.81.21.2.1.1.4
The state of the Input/Output Module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), fail(2)  

iwrEthernetMode 1.3.6.1.4.1.81.21.2.1.1.5
Determines whether the ex10bt(2) LAN controller is connected to the front panel 10BaseT or to backplane bus4(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bus4(1), ex10bt(2), notSupported(255)  

iwrPrimaryFDDIInsert 1.3.6.1.4.1.81.21.2.1.1.6
This variable is specific to the IEFR router and reflect the status of the Primary - P FDDI interfaces of the router. There is a corresponding LED for each one on the front pannel and this information may be used to build a 'real-life' representation of the module's pannel on a management application.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inserted(1), bypassed(2), notSupported(255)  

iwrSecondaryFDDIInsert 1.3.6.1.4.1.81.21.2.1.1.7
This variable is specific to the IEFR router and reflect the status of the Secondary - S FDDI interfaces of the router. There is a corresponding LED for each one on the front pannel and this information may be used to build a 'real-life' representation of the module's pannel on a management application.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inserted(1), bypassed(2), notSupported(255)  

iwrWANTable 1.3.6.1.4.1.81.21.2.2
WAN data table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IwrWANEntry

iwrWANEntry 1.3.6.1.4.1.81.21.2.2.1
Entry in the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IwrWANEntry  

iwrWANGroupId 1.3.6.1.4.1.81.21.2.2.1.1
Slot number in which the module is located.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iwrWANPortId 1.3.6.1.4.1.81.21.2.2.1.2
WAN port index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iwrWANConnection 1.3.6.1.4.1.81.21.2.2.1.3
WAN connection status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2)  

iwrWANPortCableType 1.3.6.1.4.1.81.21.2.2.1.4
Cable type connected to the specified WAN port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER x21(1), rs232(2), v35(3)  

iwrInterfaceAddrTable 1.3.6.1.4.1.81.21.2.3
The table contain for each interface: 1. The IP address that was configured to the interface. 2. The IP netmask that was configured to the interface. All the network bits are set to 1 and all the hosts bits are set to 0. 3. The Mac Address assigned to the interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IwrInterfaceEntry

iwrInterfaceEntry 1.3.6.1.4.1.81.21.2.3.1
Entry in the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IwrInterfaceEntry  

iwrInterfaceGroupId 1.3.6.1.4.1.81.21.2.3.1.1
Slot number in which the module is located.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iwrInterfaceId 1.3.6.1.4.1.81.21.2.3.1.2
IP Interface port index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

iwrInterfaceAddr 1.3.6.1.4.1.81.21.2.3.1.3
The IP Address of this indexed port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

iwrInterfaceMask 1.3.6.1.4.1.81.21.2.3.1.4
The IP Address Mask of this indexed port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

iwrInterfaceMacAddress 1.3.6.1.4.1.81.21.2.3.1.5
The Mac Address of this indexed interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

itrGroupTable 1.3.6.1.4.1.81.21.3.1
Table of attributes pertaining to the ITRE module.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ItrGroupEntry

itrGroupEntry 1.3.6.1.4.1.81.21.3.1.1
An entry in the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ItrGroupEntry  

itrGroupId 1.3.6.1.4.1.81.21.3.1.1.1
Slot number in which the module is located.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

itrMainSWVersion 1.3.6.1.4.1.81.21.3.1.1.2
Software version of the main CPU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

itrConfigState 1.3.6.1.4.1.81.21.3.1.1.3
Configuration state of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER local(1), remote(2), notSupported(255)  

itrModuleState 1.3.6.1.4.1.81.21.3.1.1.4
State of the ISTC/IFTC modules.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oper(1), load(2), setup(3), notSupported(255)  

itrLinkTable 1.3.6.1.4.1.81.21.3.2
ITRE links table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ItrLinkEntry

itrLinkEntry 1.3.6.1.4.1.81.21.3.2.1
Entry in the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ItrLinkEntry  

itrLinkGroupId 1.3.6.1.4.1.81.21.3.2.1.1
Slot number in which the module is located.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

itrLinkPortId 1.3.6.1.4.1.81.21.3.2.1.2
Link identifier.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

itrLinkIf 1.3.6.1.4.1.81.21.3.2.1.3
Interface type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER v11(1), v24(2), v35(3), dte-dce(4)  

itrLinkMode 1.3.6.1.4.1.81.21.3.2.1.4
Synchronous or asynchronous modes on the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sync(1), async(2)  

itrLinkAsyncRate 1.3.6.1.4.1.81.21.3.2.1.5
Possible link speeds that can be set in asynchronous mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER r2400(1), r4800(2), r9600(3), r14400(4), r19200(5), r38400(6), r56000(7), r57600(8), r64000(9), r115200(10), unknown(255)  

itrLinkSyncRate 1.3.6.1.4.1.81.21.3.2.1.6
Link speeds in synchronous mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER r1200(1), r2400(2), r4800(3), r9600(4), r14400(5), r19200(6), r38400(7), r48000(8), r56000(9), r57600(10), r64000(11), r112000(12), r128000(13), r256000(14), r384000(15), r512000(16), r786000(17), r1024000(18), r1544000(19), r2048000(20), unknown(255)  

itrLinkParity 1.3.6.1.4.1.81.21.3.2.1.7
This attribute enables/disables parity checking.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

itrLinkParityEvenOdd 1.3.6.1.4.1.81.21.3.2.1.8
Even or odd parity.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER even(1), odd(2), notSupported(255)  

itrLinkStopBit 1.3.6.1.4.1.81.21.3.2.1.9
Number of stop bits (1 or 2 ) in asynchronous mode. The value 'none' is returned in synchronous mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER one(1), two(2), none(3), notSupported(255)  

itrLinkRemoteLANConn 1.3.6.1.4.1.81.21.3.2.1.10
This attribute shows whether the remote ITRE is connected to the LAN.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2), notSupported(255)  

itrLinkFunctionalStatus 1.3.6.1.4.1.81.21.3.2.1.11
The attribute represents the status of the WAN link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), fail(2), noRxClk(3), disable(4)  

itrLinkAdminStatus 1.3.6.1.4.1.81.21.3.2.1.12
The administrative status of the WAN port of the ITRE/IERE family. enabled(1) enables the WAN link, disabled(3) disables it, and enableddOnDemand(2) allows the ITRE/IERE to decide whether to open the port or close it. In this case, it's RO value and the state of the module is reflected in the genPortAdminStatus object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), enabledOnDemand(2), disabled(3), notSupported(255)  

itrLinkReset 1.3.6.1.4.1.81.21.3.2.1.13
Reset the WAN link
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2), notSupported(255)  

itrLinkConnectionStatus 1.3.6.1.4.1.81.21.3.2.1.14
This attribute represents the end-to-end connection status of the WAN link. When the connection is ok, the link is 'on(1)'. When the connection is lost the link is 'trying(3)'constantly to re-establish the connection until it becomes 'on(1)' or 'off(2)' .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2), trying(3), notSupported(255)  

itrLinkDataBits 1.3.6.1.4.1.81.21.3.2.1.15
Number of data bits (7 or 8) in asynchronous mode. The value 'notSupported' is returned in synchronous mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER seven(1), eight(2), none(3), notSupported(255)  

itrLinkControlSignalsMode 1.3.6.1.4.1.81.21.3.2.1.16
The value of this attribute determines the control signals (RTS,CTS, CD) mode while working with a MODEM, either in synchronous or asynchronous mode. When the Control Signals Mode is disabled, there is no flow control with the MODEM.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), notSupported(255)  

itrLinkParityType 1.3.6.1.4.1.81.21.3.2.1.17
This attribute represents the parity type in asynchronous mode. The value 'none' is returned in synchronous mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noParity(1), even(2), odd(3), none(4), notSupported(255)  

lntFddiPort 1.3.6.1.4.1.81.25.1
OBJECT IDENTIFIER    

lntFddiPortTable 1.3.6.1.4.1.81.25.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LntFddiPortEntry

lntFddiPortEntry 1.3.6.1.4.1.81.25.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LntFddiPortEntry  

lntFddiPortGroupId 1.3.6.1.4.1.81.25.1.1.1.1
Id of the slot to which the fddi port belongs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

lntFddiPortId 1.3.6.1.4.1.81.25.1.1.1.2
Id of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

lntFddiPortMACCurrentPath 1.3.6.1.4.1.81.25.1.1.1.3
Indicates the association of the MAC with the link path.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

lntFddiPortOpticalSwitchExist 1.3.6.1.4.1.81.25.1.1.1.4
This attribute describes the presence of the optical switch and for existing optical switches describes the possibility of the auto-reconfiguration of path resources in the case of power fault.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER exist(1), not-exist(2)  

lntFddiPortRingConfiguration 1.3.6.1.4.1.81.25.1.1.1.5
Attribute which summarizes the status of the fddi link. It is related to the light detection in the physical fiber.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER thru(1), wrap-a(2), wrap-b(3), wrap-s(4), isolate(5), dualHomingA(6), dualHomingB(7)  

lntFddiPortLineStatusA 1.3.6.1.4.1.81.25.1.1.1.6
Attribute that reflects the status of fddi line, interface a.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER als(1), ils(2), mls(3), hls(4), qls(5), nls(6), sils(7)  

lntFddiPortLineStatusB 1.3.6.1.4.1.81.25.1.1.1.7
Attribute that reflects the status of fddi line, interface b.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER als(1), ils(2), mls(3), hls(4), qls(5), nls(6), sils(7)  

lntFddiPortRxTotalPackets 1.3.6.1.4.1.81.25.1.1.1.8
Number of total packets, including errors, received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lntFddiPortRxTotalOctets 1.3.6.1.4.1.81.25.1.1.1.9
Number of total octets, including errors, received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lntFddiPortTxTotalPackets 1.3.6.1.4.1.81.25.1.1.1.10
Number of total packets, including errors, transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lntFddiPortTxTotalOctets 1.3.6.1.4.1.81.25.1.1.1.11
Number of total octets, including errors, transmitted
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

lntFddiPortIPXtoFDDIMatching 1.3.6.1.4.1.81.25.1.1.1.12
Conversion matching from IPX to FDDI in Novell environment
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER llc(1), snap(2), tunneled(3), fddi-raw(4), notSupported(255)  

lntFddiPortFDDItoIPXMatching 1.3.6.1.4.1.81.25.1.1.1.13
Conversion matching from FDDI to IPX in Novell environment
Status: mandatory Access: read-write
OBJECT-TYPE    