NEC-MIB

File: NEC-MIB.mib (167939 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
SNMPv2-TC-v1

Imported symbols

enterprises Counter IpAddress
Opaque OBJECT-TYPE DisplayString
ifIndex DateAndTime TruthValue

Defined Types

NodeStatusEntry  
SEQUENCE    
  nodeStatusIndex INTEGER
  nodeStatusPower INTEGER
  nodeStatusSwitchMode INTEGER
  nodeStatusSwitch INTEGER

NodePCMCIAEntry  
SEQUENCE    
  nodePCMCIAIndex INTEGER
  nodePCMCIAStatus INTEGER
  nodePCMCIAType INTEGER

SlotIfConfEntry  
SEQUENCE    
  slotIfConfIndex INTEGER
  slotIfConfPhysType INTEGER
  slotIfConfRev DisplayString
  slotIfConfStatus INTEGER
  slotIfConfBufferType INTEGER
  slotIfConfBufferRev DisplayString
  slotIfConfReset INTEGER
  slotIfConfResetResult INTEGER

LinfFilterMaskVpi  
INTEGER -1 | 0..12    

LinfFilterMaskVci  
INTEGER -1 | 0..14    

LinfCellMappingMode  
INTEGER direct(1), plcp(2)    

LinfScramble  
INTEGER on(1), off(2)    

LinfLBO  
INTEGER low(1), hi(2), length-0-110(3), length-110-220(4), length-220-330(5), length-330-440(6), length-440-550(7), length-550-660(8), length-over660(9)    

LinfFrameMode  
INTEGER c-bit(1), m23(2), g832-g804(3), g751(4), m13(5), esf(6), sf(7)    

LinfMinVci  
INTEGER 0..16383    

LinfMaxVci  
INTEGER 0..16383    

LinfService  
INTEGER unstructured(1), structured(2)    

LinfInterWorking  
INTEGER network(1), service(2)    

LinfVendor  
INTEGER notApplicable(1), stratacom(2), digital-equipment(3), northan-telecom(4), cisco-systems(5)    

LinfFractionalType  
INTEGER unstructured(1), fractional(2)    

LinfFractionalSet  
INTEGER    

LinfCasMode  
INTEGER notApplicable(1), basic(2), cas(3)    

LinfCodingMode  
INTEGER hdb3(1), ami(2)    

LinfUnUsedParam  
INTEGER unused(-1)    

LinfStatusEntry  
SEQUENCE    
  linfIndex INTEGER
  linfStatus INTEGER
  linfLoopBack INTEGER
  linfConf INTEGER
  linfFwdAvailableBandWidth INTEGER
  linfBkwdAvailableBandWidth INTEGER
  linfJ2Rate INTEGER
  linfCacFactor INTEGER
  linfLoopBackCause INTEGER
  linfBandWidth INTEGER
  linfRecommendation INTEGER
  linfUnassignedIdle INTEGER
  linfMaxActiveVpiBits INTEGER
  linfMaxActiveVciBits INTEGER
  linfPhysType INTEGER
  linfParam1 INTEGER
  linfParam2 INTEGER
  linfParam3 INTEGER
  linfParam4 INTEGER
  linfParam5 INTEGER
  linfParam6 INTEGER
  linfParam7 INTEGER

LinfFifoConfEntry  
SEQUENCE    
  linfFifoConfifIndex INTEGER
  linfFifoConfIndex INTEGER
  linfFifoConfStatus INTEGER
  linfFifoConfPeekRate INTEGER
  linfFifoConfSustainRate INTEGER
  linfFifoConfMaxBurstSize INTEGER
  linfFifoConfRowStatus INTEGER

ConnPvcEntry  
SEQUENCE    
  connPvcPort INTEGER
  connPvcVpi INTEGER
  connPvcVci INTEGER
  connPvcDirection INTEGER
  connPvcIndex INTEGER
  connPvcContrastPort INTEGER
  connPvcContrastVpi INTEGER
  connPvcContrastVci INTEGER
  connPvcTopology INTEGER
  connPvcTrafficType INTEGER
  connPvcFifoIndex INTEGER
  connPvcContrastFifoIndex INTEGER
  connPvcTrfConf INTEGER
  connPvcTrfResult INTEGER
  connPvcParam1 INTEGER
  connPvcContrastParam1 INTEGER
  connPvcParam2 DisplayString
  connPvcContrastParam2 DisplayString
  connPvcParam3 INTEGER
  connPvcContrastParam3 INTEGER
  connPvcParam4 INTEGER
  connPvcContrastParam4 INTEGER
  connPvcParam5 INTEGER
  connPvcContrastParam5 INTEGER
  connPvcParam6 INTEGER
  connPvcContrastParam6 INTEGER
  connPvcParam7 INTEGER
  connPvcContrastParam7 INTEGER

ConnPvcTrfEntry  
SEQUENCE    
  connPvcTrfInCells OCTET STRING
  connPvcTrfInCellsCounters Counter
  connPvcTrfOutCells OCTET STRING
  connPvcTrfOutCellsCounters Counter
  connPvcTrfInDropCells OCTET STRING
  connPvcTrfInDropCellsCounters Counter

ConnConfIfEntry  
SEQUENCE    
  connConfIfPvcs INTEGER
  connConfIfSvcs INTEGER
  connConfIfSoftPvcs INTEGER

DstAtmAddressFormat  
INTEGER noWriting(-1), e-164(1), nsap(2)    

DstAtmAddressLength  
INTEGER 4..160 | -1    

DstAtmAddress  
OCTET STRING Size(0..20)    

DstPrimaryIfIndex  
INTEGER 1..99 | -1    

DstPrimaryVPI  
INTEGER 0..4095 | -1    

DstSecondaryIfIndex  
INTEGER 1..99 | -1    

DstSecondaryVPI  
INTEGER 0..4095 | -1    

ConnRouteOpeFailureCause  
INTEGER noWriting(-1), other(1), allocateSucceed(2), tableIsFull(3), parameterIsNotEnough(4), specifiedAddressIsIllegal(5), specifiedAddressIsAlreadyExisting(6), specifiedAddressIsNotExisting(7)    

ConnRouteEntry  
SEQUENCE    
  connRouteType INTEGER
  connRoutePrimaryIfIndex INTEGER
  connRoutePrimaryVPI INTEGER
  connRouteSecondaryIfIndex INTEGER
  connRouteSecondaryVPI INTEGER
  connRouteTertiaryIfIndex INTEGER
  connRouteTertiaryVPI INTEGER
  connRouteFourthryIfIndex INTEGER
  connRouteFourthryVPI INTEGER
  connRouteFifthryIfIndex INTEGER
  connRouteFifthryVPI INTEGER
  connRouteSixthryIfIndex INTEGER
  connRouteSixthryVPI INTEGER
  connRouteSeventhryIfIndex INTEGER
  connRouteSeventhryVPI INTEGER
  connRoutePrimaryStatus INTEGER
  connRoutePrimaryCause INTEGER
  connRouteAtmAddressFormat DstAtmAddressFormat
  connRouteAtmAddressLength DstAtmAddressLength
  connRouteAtmAddress DstAtmAddress

ConnSoftPvcEntry  
SEQUENCE    
  connSoftPvcIndex INTEGER
  connSoftPvcTopology INTEGER
  connSoftPvcTrafficType INTEGER
  connSoftPvcEndpointType INTEGER
  connSoftPvcRetry INTEGER
  connSoftPvcSrcAtmAddressFormat INTEGER
  connSoftPvcSrcAtmAddressLength INTEGER
  connSoftPvcSrcAtmAddress OCTET STRING
  connSoftPvcSrcIfIndex INTEGER
  connSoftPvcSrcVPI INTEGER
  connSoftPvcSrcVCI INTEGER
  connSoftPvcDstAtmAddressFormat INTEGER
  connSoftPvcDstAtmAddressLength INTEGER
  connSoftPvcDstAtmAddress OCTET STRING
  connSoftPvcDstIfIndex INTEGER
  connSoftPvcDstVPI INTEGER
  connSoftPvcDstVCI INTEGER
  connSoftPvcRowStatus INTEGER
  connSoftPvcCause INTEGER
  connSoftPvcRestRetry INTEGER
  connSoftPvcSrcFifoIndex INTEGER
  connSoftPvcDstFifoIndex INTEGER
  connSoftPvcNodeKind INTEGER
  connSoftPvcSrcParam1 INTEGER
  connSoftPvcDstParam1 INTEGER
  connSoftPvcSrcParam2 DisplayString
  connSoftPvcDstParam2 DisplayString
  connSoftPvcSrcParam3 INTEGER
  connSoftPvcDstParam3 INTEGER
  connSoftPvcSrcParam4 INTEGER
  connSoftPvcDstParam4 INTEGER
  connSoftPvcSrcParam5 INTEGER
  connSoftPvcDstParam5 INTEGER
  connSoftPvcSrcParam6 INTEGER
  connSoftPvcDstParam6 INTEGER
  connSoftPvcSrcParam7 INTEGER
  connSoftPvcDstParam7 INTEGER

ConnSoftPvcSrcAtmAddressFormat  
INTEGER noWriting(-1), e-164(1), nsap(2)    

ConnSoftPvcDstAtmAddressFormat  
INTEGER noWriting(-1), e-164(1), nsap(2)    

ConnSoftPvcEstSrcInfIndex  
INTEGER 1..128    

ConnSoftPvcEstablishedSrcInfEntry  
SEQUENCE    
  connSoftPvcEstablishedSrcInf Opaque
  connSoftPvcEstSrcInfIndex ConnSoftPvcEstSrcInfIndex

ConnOamEntry  
SEQUENCE    
  connOamPort INTEGER
  connOamIndex INTEGER
  connOamContrastPort INTEGER
  connOamVpi INTEGER
  connOamContrastVpi INTEGER
  connOamVci INTEGER
  connOamContrastVci INTEGER
  connOamPoint INTEGER
  connOamMode INTEGER
  connOamSection INTEGER
  connOamStatus INTEGER
  connOamDefectType INTEGER
  connOamDefectNodeID OCTET STRING

ConnProfileIndex  
INTEGER    

ConnProfileEntry  
SEQUENCE    
  connProfileIndex ConnProfileIndex
  connProfileRowStatus INTEGER
  connProfileCause INTEGER
  connProfileTrafficType INTEGER
  connProfileName DisplayString
  connProfileParam1 INTEGER
  connProfileParam2 INTEGER
  connProfileParam3 INTEGER
  connProfileParam4 INTEGER

ConnSvcEntry  
SEQUENCE    
  connSvcIndex INTEGER
  connSvcInf Opaque

ConnCeVcEntry  
SEQUENCE    
  connCeVcPort INTEGER
  connCeVcVci INTEGER
  connCeVcRowStatus INTEGER
  connCeVcCause INTEGER
  connCeVcDirection INTEGER
  connCeVcUpPartialFillSize INTEGER
  connCeVcDownPartialFillSize INTEGER
  connCeVcCondition INTEGER
  connCeVcCDVT INTEGER
  connCeVcUpPCR INTEGER
  connCeVcDownPCR INTEGER
  connCeVcUpTimeSlot1 INTEGER
  connCeVcDownTimeSlot1 INTEGER
  connCeVcUpTimeSlot2 INTEGER
  connCeVcDownTimeSlot2 INTEGER
  connCeVcUpTimeSlot3 INTEGER
  connCeVcDownTimeSlot3 INTEGER

ConnFrDlciEntry  
SEQUENCE    
  connFrDlciPort INTEGER
  connFrDlciIndex INTEGER
  connFrDlciRowStatus INTEGER
  connFrDlciCause INTEGER
  connFrDlciFrProfile DisplayString
  connFrDlciPCR INTEGER
  connFrDlciSCR INTEGER
  connFrDlciMBS INTEGER

ConnFrProfileIndex  
INTEGER    

ConnFrProfileEntry  
SEQUENCE    
  connFrProfileIndex ConnFrProfileIndex
  connFrProfileRowStatus INTEGER
  connFrProfileCause INTEGER
  connFrProfileName DisplayString
  connFrProfileInterworkingType INTEGER
  connFrProfileCIR INTEGER
  connFrProfileDEtoCLP INTEGER
  connFrProfileCLPValue INTEGER
  connFrProfileCLPtoDE INTEGER
  connFrProfileDEValue INTEGER
  connFrProfileCapsulationMode INTEGER
  connFrProfileCongestionMode INTEGER

PerfIfEntry  
SEQUENCE    
  perfIfIndex INTEGER
  perfIfReceivedCells OCTET STRING
  perfIfReceivedCellsCounters Counter
  perfIfTransmittedCells OCTET STRING
  perfIfTransmittedCellsCounters Counter
  perfIfMisDelivdCells OCTET STRING
  perfIfMisDelivdCellsCounters Counter
  perfIfThresholdExcessCells OCTET STRING
  perfIfThresholdExcessCellsCounters Counter
  perfIfUpcErrorCells OCTET STRING
  perfIfUpcErrorCellsCounters Counter

PerfIfSlotEntry  
SEQUENCE    
  perfIfSlotReceivedCells OCTET STRING
  perfIfSlotTransmittedCells OCTET STRING
  perfIfSlotInDropCells OCTET STRING
  perfIfSlotReceivedCellsCounters Counter
  perfIfSlotTransmittedCellsCounters Counter
  perfIfSlotInDropCellsCounters Counter
  perfIfSlotHCThresholdExcessCells OCTET STRING
  perfIfSlotThresholdExcessCells Counter
  perfIfSlotHCUpcErrorCells OCTET STRING
  perfIfSlotUpcErrorCells Counter

PerfIfPhysEntry  
SEQUENCE    
  perfIfPhysPort INTEGER
  perfIfPhysHCHecErorrs OCTET STRING
  perfIfPhysHecErorrs INTEGER
  perfIfPhysHCHecDropCells OCTET STRING
  perfIfPhysHecDropCells INTEGER
  perfIfPhysHCB1Errors OCTET STRING
  perfIfPhysB1Errors INTEGER
  perfIfPhysHCB2Errors OCTET STRING
  perfIfPhysB2Errors INTEGER
  perfIfPhysHCB3Errors OCTET STRING
  perfIfPhysHCB3Errors INTEGER
  perfIfPhysHCPathFEBEs OCTET STRING
  perfIfPhysPathFEBEs INTEGER
  perfIfPhysHCLineFEBEs OCTET STRING
  perfIfPhysLineFEBEs INTEGER
  perfIfPhysHCFramingErrors OCTET STRING
  perfIfPhysFramingErrors INTEGER
  perfIfPhysHCReceivedCells OCTET STRING
  perfIfPhysReceivedCells INTEGER
  perfIfPhysHCTransmittedCells OCTET STRING
  perfIfPhysTransmittedCells INTEGER
  perfIfPhysHCIdelUnassignedCells OCTET STRING
  perfIfPhysIdelUnassignedCells INTEGER
  perfIfPhysHCFEBEErrors OCTET STRING
  perfIfPhysFEBEErrors INTEGER
  perfIfPhysHCFEBEs OCTET STRING
  perfIfPhysFEBEs INTEGER
  perfIfPhysHCPathParityErrors OCTET STRING
  perfIfPhysPathParityErrors INTEGER
  perfIfPhysHCParityErrors OCTET STRING
  perfIfPhysParityErrors INTEGER
  perfIfPhysHCSEZs OCTET STRING
  perfIfPhysSEZs INTEGER
  perfIfPhysHCBitErrors OCTET STRING
  perfIfPhysBitErrors INTEGER
  perfIfPhysHCLcvErrors OCTET STRING
  perfIfPhysLcvErrors INTEGER
  perfIfPhysHCBip8Errors OCTET STRING
  perfIfPhysBip8Errors INTEGER
  perfIfPhysHCIecErrors OCTET STRING
  perfIfPhysIecErrors INTEGER
  perfIfPhysHCFramingPatternErrors OCTET STRING
  perfIfPhysFramingPatternErrors INTEGER
  perfIfPhysHCFramingBitErrors OCTET STRING
  perfIfPhysFramingBitErrors INTEGER
  perfIfPhysHCCrcErrors OCTET STRING
  perfIfPhysCrcErrors INTEGER

CardStatusEntry  
SEQUENCE    
  cardStatusServerType INTEGER
  cardStatusRevision DisplayString
  cardStatusMateSlotNumber INTEGER
  cardStatusMode INTEGER
  cardStatusPriority INTEGER
  cardStatusAtmAddr OCTET STRING
  cardStatusMateAtmAddr OCTET STRING

CardOpeEntry  
SEQUENCE    
  cardOpeReset INTEGER
  cardOpeDiagnosis INTEGER
  cardOpeSave INTEGER
  cardOpeSaveResult INTEGER
  cardOpeCopy INTEGER
  cardOpeCopyResult INTEGER

ClockSlaveLineStatus  
INTEGER notApplicable(1), active(2), standby(3), hardError(4), adminDown(5), notExist(6), linfDown(7), testing(8), notSupported(9), syncronizedFailure(10), lossOf64kClock(11), lossOf8kClock(12), frequencyOutOfRange(13)    

PnniAtmAddr  
OCTET STRING Size(20)    

PnniNodeId  
OCTET STRING Size(22)    

PnniPeerGroupId  
OCTET STRING Size(14)    

PnniLevel  
INTEGER 0..104    

PnniNodeEntry  
SEQUENCE    
  pnniNodeLevel PnniLevel
  pnniNodeId PnniNodeId
  pnniNodeAtmAddress PnniAtmAddr
  pnniNodePeerGroupId PnniPeerGroupId
  pnniNodeRestrictedTransit TruthValue
  pnniNodeRestrictedBranching TruthValue
  pnniNodeLeadershipPriority INTEGER

Defined Values

nec 1.3.6.1.4.1.119
OBJECT IDENTIFIER    

necProduct 1.3.6.1.4.1.119.1
OBJECT IDENTIFIER    

atomis 1.3.6.1.4.1.119.1.14
OBJECT IDENTIFIER    

m7-phase2 1.3.6.1.4.1.119.1.14.9
OBJECT IDENTIFIER    

m7-corporate 1.3.6.1.4.1.119.1.14.12
OBJECT IDENTIFIER    

nec-mib 1.3.6.1.4.1.119.2
OBJECT IDENTIFIER    

necProductDepend 1.3.6.1.4.1.119.2.3
OBJECT IDENTIFIER    

atomis-mib 1.3.6.1.4.1.119.2.3.14
OBJECT IDENTIFIER    

m7-phase2-mib 1.3.6.1.4.1.119.2.3.14.9
OBJECT IDENTIFIER    

node 1.3.6.1.4.1.119.2.3.14.9.1
OBJECT IDENTIFIER    

slot 1.3.6.1.4.1.119.2.3.14.9.2
OBJECT IDENTIFIER    

linf 1.3.6.1.4.1.119.2.3.14.9.3
OBJECT IDENTIFIER    

conn 1.3.6.1.4.1.119.2.3.14.9.4
OBJECT IDENTIFIER    

perf 1.3.6.1.4.1.119.2.3.14.9.5
OBJECT IDENTIFIER    

scale 1.3.6.1.4.1.119.2.3.14.9.6
OBJECT IDENTIFIER    

card 1.3.6.1.4.1.119.2.3.14.9.7
OBJECT IDENTIFIER    

clock 1.3.6.1.4.1.119.2.3.14.9.8
OBJECT IDENTIFIER    

diag 1.3.6.1.4.1.119.2.3.14.9.9
OBJECT IDENTIFIER    

pnni 1.3.6.1.4.1.119.2.3.14.9.10
OBJECT IDENTIFIER    

matCmd 1.3.6.1.4.1.119.2.3.14.9.11
OBJECT IDENTIFIER    

m7-corporate-mib 1.3.6.1.4.1.119.2.3.14.12
OBJECT IDENTIFIER    

nodeStatus 1.3.6.1.4.1.119.2.3.14.9.1.1
OBJECT IDENTIFIER    

nodeStatusOperStatus 1.3.6.1.4.1.119.2.3.14.9.1.1.1
Indicate operational status of the equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER down(1), active(2), installing(3)  

nodeStatusStartTime 1.3.6.1.4.1.119.2.3.14.9.1.1.2
Date and Time when the equipment was last restarted
Status: mandatory Access: read-only
OBJECT-TYPE    
  DateAndTime  

nodeStatusNodeId 1.3.6.1.4.1.119.2.3.14.9.1.1.3
Node ID of the equipment
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

nodeStatusSelfSystem 1.3.6.1.4.1.119.2.3.14.9.1.1.4
Indicate which system of the SW-Engine the NMS is connected with.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER system-0(1), system-1(2)  

nodeStatusSwitchType 1.3.6.1.4.1.119.2.3.14.9.1.1.5
Indicate the type of SW-Engine.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER sw-Engine-5G(1), sw-Engine-10G(2)  

nodeStatusFan 1.3.6.1.4.1.119.2.3.14.9.1.1.6
Indicate operational status of the FAN of the equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), failure(2)  

nodeStatusEnvironment 1.3.6.1.4.1.119.2.3.14.9.1.1.7
Peripheral temperature environment of the equipment. If the peripheral temperature exceeds 50 C, this object enters noGood(2).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER good(1), noGood(2)  

nodeStatusTable 1.3.6.1.4.1.119.2.3.14.9.1.2
Table which indicates the status of each part of the equipment.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NodeStatusEntry

nodeStatusEntry 1.3.6.1.4.1.119.2.3.14.9.1.2.1
Entry of the configuration of the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NodeStatusEntry  

nodeStatusIndex 1.3.6.1.4.1.119.2.3.14.9.1.2.1.1
Index of the system configuration of the equipment
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

nodeStatusPower 1.3.6.1.4.1.119.2.3.14.9.1.2.1.2
Indicate the status of the Power Unit of the equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), failure(2), notInstalled(99)  

nodeStatusSwitchMode 1.3.6.1.4.1.119.2.3.14.9.1.2.1.3
Indicate operational mode of SW-Engine of the equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER act(1), sby(2), notInstalled(99)  

nodeStatusSwitch 1.3.6.1.4.1.119.2.3.14.9.1.2.1.4
Indicate the status of the SW-Engine of the equipment.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), failure(2), diagnostics(3), diagnosis-status-NG(4), initializing(5), notInstalled(99)  

nodePCMCIATable 1.3.6.1.4.1.119.2.3.14.9.1.3
Table which indicates the status of the PCMCIA card. Every PCMCIA slot is provided with an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NodePCMCIAEntry

nodePCMCIAEntry 1.3.6.1.4.1.119.2.3.14.9.1.3.1
Entry of nodePCMCIATable
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NodePCMCIAEntry  

nodePCMCIAIndex 1.3.6.1.4.1.119.2.3.14.9.1.3.1.1
PCMCIA slot number per SW-Engine
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..2  

nodePCMCIAStatus 1.3.6.1.4.1.119.2.3.14.9.1.3.1.2
Status of PCMCIA card
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), failure(2), initializing(3), busy(4), unknown(5), notInstalled(99)  

nodePCMCIAType 1.3.6.1.4.1.119.2.3.14.9.1.3.1.3
Type of installed PCMCIA card
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER lan-card(1), ata-card(2), unknown(3), notInstalled(99)  

nodeOpe 1.3.6.1.4.1.119.2.3.14.9.1.4
OBJECT IDENTIFIER    

nodeOpeSave 1.3.6.1.4.1.119.2.3.14.9.1.4.1
Save processing. Save System Configuration information in FROM. The result is indicated in nodeOpeSaveResult. The value at read is always noOperation (1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(1), save(2)  

nodeOpeSaveResult 1.3.6.1.4.1.119.2.3.14.9.1.4.2
The result of SAVE processing OK/NG indicate that SAVE processing completed/failed, respectively. (NearEND) indicates that the number of write counts approaches to the limit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER succeed(1), succeed-0(2), succeed-1(3), temporaryFailure(4), nearend(5), nearend-0(6), nearend-0-failure-1(7), nearend-1(8), nearend-1-failure-0(9), notReady(10), ready(11)  

nodeOpeCopy 1.3.6.1.4.1.119.2.3.14.9.1.4.3
Copy the system configuration information/LM to the FROM of other system. The result is indicated in nodeOpeCopyResult. The value at read is always noOperation(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(1), copy-all-from-act(2), copy-all-from-sby(3), copy-config-from-act(4), copy-config-from-sby(5), copy-system-from-act(6), copy-system-from-sby(7)  

nodeOpeCopyResult 1.3.6.1.4.1.119.2.3.14.9.1.4.4
Result of the copy processing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER succeed(1), temporaryFailure(2), nearend(3), notReady(4), ready(5)  

nodeOpeReset 1.3.6.1.4.1.119.2.3.14.9.1.4.5
System Reset processing The value at read is always noOperation(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(1), reset-act(2), reset-sby(3), ach(4)  

slotIfConfTable 1.3.6.1.4.1.119.2.3.14.9.2.1
Table which indicates the line card configuration of the equipment
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SlotIfConfEntry

slotIfConfEntry 1.3.6.1.4.1.119.2.3.14.9.2.1.1
Entry of the line card configuration
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SlotIfConfEntry  

slotIfConfIndex 1.3.6.1.4.1.119.2.3.14.9.2.1.1.1
Index of line card configuration
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

slotIfConfPhysType 1.3.6.1.4.1.119.2.3.14.9.2.1.1.2
PMD layer/physical layer format of the line card. Above stated [oc3c], [oc12c] are ATM Form conformed names. They are corresponding to the ITU-T conformed names as follows: oc3c - STM1 oc12 - STM4 sts3c - STM1
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), taxi-100M(2), oc3c-SMF-Long(3), oc3c-SMF-Short(4), oc3c-MMF(5), relay-6Mcel(6), j2-6M-4M-3M(7), utp-5(8), oc12c-SMF-Type-A(9), oc12c-SMF-Type-B(10), ds3(11), e3(12), bts-1(13), bts-4(14), primary-1536K-1152K-768K-512K-384K-256K-192K(15), ds1(16), e1(17), oc3c-POF(18), sts3c-COAXIAL(19), vod-RxHFC4M(50), vod-TxHFC27M(51), svr(52), fr-ds1(53), fr-e1(54), dcs(55), ce-ds3(56), ce-ds1(57), ce-e1(58), ce-J2(59), svr2(60), notInstalled(99)  

slotIfConfRev 1.3.6.1.4.1.119.2.3.14.9.2.1.1.3
The revision of the line cards.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

slotIfConfStatus 1.3.6.1.4.1.119.2.3.14.9.2.1.1.4
Operational status of the line cards.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), inService(2), outOfService(3), testing(4), initializing(5), installing(6), notInstalled(99)  

slotIfConfBufferType 1.3.6.1.4.1.119.2.3.14.9.2.1.1.5
The Buffer ID of the line cards.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ph1-buffer(2), ph2-buffer(3), fr-buffer(4), fr-buffer2(5), notInstalled(99)  

slotIfConfBufferRev 1.3.6.1.4.1.119.2.3.14.9.2.1.1.6
The revision of the line card's buffers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

slotIfConfReset 1.3.6.1.4.1.119.2.3.14.9.2.1.1.7
Line card reset. The result of the reset order is indicated in slotIfConfResetResult.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(1), reset(2), notInstalled(99)  

slotIfConfResetResult 1.3.6.1.4.1.119.2.3.14.9.2.1.1.8
The current result of the reset order by slotIfConfReset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER succeed(1), other(2), diagnostics(3), unchangeableSlaveLine(4), notInstalled(99)  

linfStatusTable 1.3.6.1.4.1.119.2.3.14.9.3.1
Table related to the ATM specific lines which could not be defined by MIB-II. The table includes the configuration information, operational status and error types of lines.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LinfStatusEntry

linfStatusEntry 1.3.6.1.4.1.119.2.3.14.9.3.1.1
Entry of the line interface status indication.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LinfStatusEntry  

linfIndex 1.3.6.1.4.1.119.2.3.14.9.3.1.1.1
Index of the line interface status indication
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..64  

linfStatus 1.3.6.1.4.1.119.2.3.14.9.3.1.1.2
Status of the line interface or the receive clock
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), los(2), lof(3), loc(4), ais-path(5), ais-section(6), yellow-section(7), yellow-path(8), lop(9), ais(10), payload-all-one(11), rai(12), oof(13), idle(14), rdi(15), plcp-oof(16), plcp-lof(17), plcp-yellow(18), red(19), loss-of-64K-clock(80), loss-of-8K-clock(81), frequency-out-of-range(82), failure(97), administratively-down(98), notInstalled(99)  

linfLoopBack 1.3.6.1.4.1.119.2.3.14.9.3.1.1.3
Loop back status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER others(1), normal(2), localLoopBack(3), remoteLoopBack(4), notInstalled(99)  

linfConf 1.3.6.1.4.1.119.2.3.14.9.3.1.1.4
Line card type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER others(1), private-UNI(2), private-NNI(3), public-UNI(4), uni(6), nni(7), notInstalled(99)  

linfFwdAvailableBandWidth 1.3.6.1.4.1.119.2.3.14.9.3.1.1.5
Forward Available BandWidth(Mbps).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linfBkwdAvailableBandWidth 1.3.6.1.4.1.119.2.3.14.9.3.1.1.6
Backward Available BandWidth(Mbps).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linfJ2Rate 1.3.6.1.4.1.119.2.3.14.9.3.1.1.7
Indicate the line rate of the J2-dedicated line service.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER not-leased-line(1), type-3-Mbps(2), type-4point5-Mbps(3), type-6point3-Mbps(4), notInstalled(99)  

linfCacFactor 1.3.6.1.4.1.119.2.3.14.9.3.1.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 10..1000  

linfLoopBackCause 1.3.6.1.4.1.119.2.3.14.9.3.1.1.9
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER succeed(1), diagnosis(2), failure(3), notSupportedByPkg(4), alreadyRegistered(5), adminDown(6), initializing(7), notInstalled(99)  

linfBandWidth 1.3.6.1.4.1.119.2.3.14.9.3.1.1.10
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linfRecommendation 1.3.6.1.4.1.119.2.3.14.9.3.1.1.11
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), atmForum(2), itu(3), ttc(4), frameRelayForum(5), itu-t(6), ansi(7), fourVendor(8), notInstalled(99)  

linfUnassignedIdle 1.3.6.1.4.1.119.2.3.14.9.3.1.1.12
Unassigned/Idle
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), unAssigned(2), idle(3), notInstalled(99)  

linfMaxActiveVpiBits 1.3.6.1.4.1.119.2.3.14.9.3.1.1.13
The length of valid VPI bits.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

linfMaxActiveVciBits 1.3.6.1.4.1.119.2.3.14.9.3.1.1.14
The length of valid VCI bits.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..14  

linfPhysType 1.3.6.1.4.1.119.2.3.14.9.3.1.1.15
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linfParam1 1.3.6.1.4.1.119.2.3.14.9.3.1.1.16
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linfParam2 1.3.6.1.4.1.119.2.3.14.9.3.1.1.17
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linfParam3 1.3.6.1.4.1.119.2.3.14.9.3.1.1.18
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linfParam4 1.3.6.1.4.1.119.2.3.14.9.3.1.1.19
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linfParam5 1.3.6.1.4.1.119.2.3.14.9.3.1.1.20
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linfParam6 1.3.6.1.4.1.119.2.3.14.9.3.1.1.21
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linfParam7 1.3.6.1.4.1.119.2.3.14.9.3.1.1.22
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

linfFifoConfTable 1.3.6.1.4.1.119.2.3.14.9.3.2
Indicate status of FIFO on the shaper-line card. * * Relationship between PCR, SCR and MBS value. PCR >= SCR PCR >= MBS
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    LinfFifoConfEntry

linfFifoConfEntry 1.3.6.1.4.1.119.2.3.14.9.3.2.1
Entry of FIFO status indication
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  LinfFifoConfEntry  

linfFifoConfifIndex 1.3.6.1.4.1.119.2.3.14.9.3.2.1.1
Line Interface Index
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

linfFifoConfIndex 1.3.6.1.4.1.119.2.3.14.9.3.2.1.2
Index of FIFO
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

linfFifoConfStatus 1.3.6.1.4.1.119.2.3.14.9.3.2.1.3
Status of FIFO
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER normal(1), overflow(2)  

linfFifoConfPeekRate 1.3.6.1.4.1.119.2.3.14.9.3.2.1.4
Peak Cell rate (PCR) for shaper-line card.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..1412830  

linfFifoConfSustainRate 1.3.6.1.4.1.119.2.3.14.9.3.2.1.5
Sustainable Cell Rate ( SCR) for shaper-line card.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..1412830  

linfFifoConfMaxBurstSize 1.3.6.1.4.1.119.2.3.14.9.3.2.1.6
Maximum Burst Size (MBS) for the shaper-line card.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..1412830  

linfFifoConfRowStatus 1.3.6.1.4.1.119.2.3.14.9.3.2.1.7
This object is used to designate the setting method for the shaping rate from the manager. Also, this object returns the reply to the shaping rate setting request from the agent side. - 'active', which indicates that the conceptual row is available for use by the managed device; - 'notInService', which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device; - 'notReady', which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device; - 'createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have it available for use by the managed device; - 'createAndWait', which is supplied by a management station wishing to create a new instance of a conceptual row but not to have it available for use by the managed device; and, - 'destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)  

connPvc 1.3.6.1.4.1.119.2.3.14.9.4.1
OBJECT IDENTIFIER    

connPvcOpe 1.3.6.1.4.1.119.2.3.14.9.4.1.1
OBJECT IDENTIFIER    

connPvcOpeLowPort 1.3.6.1.4.1.119.2.3.14.9.4.1.1.1
Low-side line port number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65 | -1  

connPvcOpeLowVpi 1.3.6.1.4.1.119.2.3.14.9.4.1.1.2
Low-side VPI number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16383 | -1  

connPvcOpeLowVci 1.3.6.1.4.1.119.2.3.14.9.4.1.1.3
Low-side VCI number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16383 | -1  

connPvcOpeHighPort 1.3.6.1.4.1.119.2.3.14.9.4.1.1.4
High-side line port number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..65 | -1  

connPvcOpeHighVpi 1.3.6.1.4.1.119.2.3.14.9.4.1.1.5
High-side VPI number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16383 | -1  

connPvcOpeHighVci 1.3.6.1.4.1.119.2.3.14.9.4.1.1.6
High-side VCI number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16383 | -1  

connPvcOpeTopology 1.3.6.1.4.1.119.2.3.14.9.4.1.1.7
Topology of the Connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER uni-directional-VCC(1), bi-directional-VCC(2), uni-directional-VPC(3), bi-directional-VPC(4), broadcast-VPC(5), broadcast-VCC(6)  

connPvcOpeTrafficType 1.3.6.1.4.1.119.2.3.14.9.4.1.1.8
Traffic Type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER traffic-CBR(1), traffic-rt-VBR(2), traffic-nrt-VBR(3), traffic-ABR(4), traffic-UBR(5)  

connPvcOpeStatus 1.3.6.1.4.1.119.2.3.14.9.4.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER allocate(1), establish(2), add(3), delete(4), remove(5), free(6)  

connPvcOpeCause 1.3.6.1.4.1.119.2.3.14.9.4.1.1.10
The result of the connection operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rowExisting(1), allocateSucceed(2), vpivciLowBusy(3), vpivciHighBusy(4), vpivciOutOfRange(5), rateLowOverFlow(6), rateHighOverFlow(7), broadcastTableFull(8), inconsistentVPVC(9), lineDiagnosis(10), missMatchTrfType(11), illegalLowFileName(12), illegalHighFileName(13), illegalLowShaper(14), illegalHighShaper(15), illegalOperation(16), parameterIsNotEnough(17), diagnostics(18), otherFailure(19), illegalLowRateForUPC(20), illegalHighRateForUPC(21), noSpecifiedConnection(22), noCevc(23), noDlci(24), illegalTopology(25), noLowShaperForGateway(26), noHighShaperForGateway(27), noPvcLowShaperForGateway(28), noPvcHighShaperForGateway(29), missMatchTrfTypeLowShaperForGateway(30), missMatchTrfTypeHighShaperForGateway(31), leafSetAnotherLine(32), insusfficientPCRofProfile(33)  

connPvcOpeLowFifoIndex 1.3.6.1.4.1.119.2.3.14.9.4.1.1.11
Shaper number of Forward. If shaping is not performed, designate 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

connPvcOpeHighFifoIndex 1.3.6.1.4.1.119.2.3.14.9.4.1.1.12
Shaper number of Backward. If shaping is not performed, designate 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

connPvcOpeLowParam1 1.3.6.1.4.1.119.2.3.14.9.4.1.1.13
UPC mode of Forward.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), mode1(2), mode2(3), mode3(4), mode4(5), mode5(6)  

connPvcOpeHighParam1 1.3.6.1.4.1.119.2.3.14.9.4.1.1.14
UPC mode of Backward.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), mode1(2), mode2(3), mode3(4), mode4(5), mode5(6)  

connPvcOpeLowParam2 1.3.6.1.4.1.119.2.3.14.9.4.1.1.15
Profile name of Forward. If nothing is designated, the string of size(0) is designated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..10|0)  

connPvcOpeHighParam2 1.3.6.1.4.1.119.2.3.14.9.4.1.1.16
Profile name of Backward. If nothing is designated, the string of size(0) is designated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..10|0)  

connPvcTable 1.3.6.1.4.1.119.2.3.14.9.4.1.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnPvcEntry

connPvcEntry 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1
Entry of connPvcTable. e.g. receive +----------------------------------+transmit =======>| ---- uni-directional-VCC ---- |=======> (1/0/32)| |(2/0/32) =======>| ---- bi-directional-VCC ---- |=======> (1/0/33)| |(2/0/33) =======>| ---- broadcast - VCC ---+---- |=======> (1/0/34)| | |(2/0/34) | +---- |=======> | |(3/0/34) +----------------------------------+ (line/vpi/vci) connPvcContrastPort.1.0.32.1.1=2 connPvcContrastPort.2.0.32.2.1=1 connPvcContrastPort.1.0.33.3.1=2 connPvcContrastPort.2.0.33.3.1=1 connPvcContrastPort.1.0.34.5.1=2 connPvcContrastPort.1.0.34.5.2=3 connPvcContrastPort.2.0.34.4.1=1 connPvcContrastPort.3.0.34.4.1=1
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnPvcEntry  

connPvcPort 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.1
Line port number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

connPvcVpi 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.2
VPI number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

connPvcVci 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.3
VCI number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

connPvcDirection 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.4
Indicate cell flow.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER in(1), out(2), in-out(3), multi-out(4), multi-in(5)  

connPvcIndex 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.5
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

connPvcContrastPort 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.6
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connPvcContrastVpi 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.7
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connPvcContrastVci 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.8
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connPvcTopology 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.9
Topology of the Connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER uni-directional-VCC(1), bi-directional-VCC(2), uni-directional-VPC(3), bi-directional-VPC(4), broadcast-VPC(5), broadcast-VCC(6), gateway(7)  

connPvcTrafficType 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.10
Traffic Type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER traffic-CBR(1), traffic-rt-VBR(2), traffic-nrt-VBR(3), traffic-ABR(4), traffic-UBR(5)  

connPvcFifoIndex 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.11
The Shaper numbers of the direction from this endpoint to the endpoint to be switched. Value 0 means that Shaping will not be performed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

connPvcContrastFifoIndex 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.12
The Shaper number of the direction from the endpoint to be switched to this end point. Value 0 means that Shaping will not be performed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

connPvcTrfConf 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.13
Indicate Traffic control/status. If a path does not exist, noSuchName. 1. Indicate Traffic status 1) entry...registered 2) remove...not registered(initial status) 2. Register Traffic 1) Set connPvcTrfConf to 'entry', to perform the registration process. 2) Then, get connPvcTrfResult. For normal end, it contains entrySucceed, for abnormal end, it contains other value. 3. Delete Traffic 1) Set connPvcTrfConf to 'remove', to perform the deletion process. 2) Then, get connPvTrfResult. For normal end, it contains entrySucceed, for abnormal end, it contains other value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER entry(1), remove(2)  

connPvcTrfResult 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.14
Indicate the processing result after Traffic control. If the path does not exist, noSuchName. The result of the registration EntrySucceed (2) --- Normal end of the registration AlreadyEntry (3) --- Double registration tableOverflow (4) --- The number of registration is over the limit. The result of the deletion RemoveSucceed (5) --- Normal end of the deletion notEntry (6) --- Non-registration Normally, other (1) is indicated. It is the current status just after the traffic control. Once, the traffic control is got, then it returns to other (1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), entrySucceed(2), alreadyEntry(3), tableOverflow(4), removeSucceed(5), notEntry(6)  

connPvcParam1 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.15
UPC mode of the direction from this endpoint to the endpoint to be switched. If nothing is designated, or the designation is invalid, off (1) is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), mode1(2), mode2(3), mode3(4), mode4(5), mode5(6)  

connPvcContrastParam1 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.16
UPC mode of the direction from the endpoint to be switched to this end point. If nothing is designated, or the designation is invalid, off (1) is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), mode1(2), mode2(3), mode3(4), mode4(5), mode5(6)  

connPvcParam2 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.17
Profile name of the direction from this endpoint to the endpoint to be switched. If nothing is designated, or the designation is invalid, the string of size(0) is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..10|0)  

connPvcContrastParam2 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.18
Profile name of the direction from the endpoint to be switched to this end point. If nothing is designated, or the designation is invalid, the string of size(0) is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..10|0)  

connPvcParam3 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.19
PCR[cell/s] of the direction from this endpoint to the endpoint to be switched. If the value is invalid, -1 is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connPvcContrastParam3 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.20
PCR[cell/s] of the direction from the endpoint to be switched to this end point. If the value is invalid, -1 is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connPvcParam4 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.21
SCR[cell/s] of the direction from this endpoint to the endpoint to be switched. If the value is invalid, -1 is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connPvcContrastParam4 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.22
SCR[cell/s] of the direction from the endpoint to be switched to this end point. If the value is invalid, -1 is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connPvcParam5 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.23
MBS[cell] of the direction from this endpoint to the endpoint to be switched. If the value is invalid, -1 is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connPvcContrastParam5 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.24
MBS[cell] of the direction from the endpoint to be switched to this end point. If the value is invalid, -1 is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connPvcParam6 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.25
EPD(Early Packet Discard) of the direction from this endpoint to the endpoint to be switched. Indicate if the discard processing in the unit of AAL5 packet should be performed or not when the threshold is exceeded. If the value is invalid, off(1) is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

connPvcContrastParam6 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.26
EPD(Early Packet Discard) of the direction from the endpoint to be switched to this end point. Indicate if the discard processing in the unit of AAL5 packet should be performed or not when the threshold is exceeded. If the value is invalid, off(1) is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

connPvcParam7 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.27
MCR[cell/s]. Not supported here.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

connPvcContrastParam7 1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.28
MCR[cell/s]. Not supported here.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

connPvcTrfTable 1.3.6.1.4.1.119.2.3.14.9.4.1.3
Indicate traffic counter information per connection.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnPvcTrfEntry

connPvcTrfEntry 1.3.6.1.4.1.119.2.3.14.9.4.1.3.1
Entry of traffic per connection. Every INDEX is equivalent to the one defined in connPvcEntry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnPvcTrfEntry  

connPvcTrfInCells 1.3.6.1.4.1.119.2.3.14.9.4.1.3.1.1
The number of receive cells 64 bit counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

connPvcTrfInCellsCounters 1.3.6.1.4.1.119.2.3.14.9.4.1.3.1.2
The number of receive cells 32 bit counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

connPvcTrfOutCells 1.3.6.1.4.1.119.2.3.14.9.4.1.3.1.3
The number of transmit cells 64 bit counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

connPvcTrfOutCellsCounters 1.3.6.1.4.1.119.2.3.14.9.4.1.3.1.4
The number of transmit cells 32 bit counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

connPvcTrfInDropCells 1.3.6.1.4.1.119.2.3.14.9.4.1.3.1.5
The number of receive drop cells 64 bit counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

connPvcTrfInDropCellsCounters 1.3.6.1.4.1.119.2.3.14.9.4.1.3.1.6
The number of receive drop cells 32 bit counter
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

connConf 1.3.6.1.4.1.119.2.3.14.9.4.2
OBJECT IDENTIFIER    

connConfNode 1.3.6.1.4.1.119.2.3.14.9.4.2.1
OBJECT IDENTIFIER    

connConfNodePvcs 1.3.6.1.4.1.119.2.3.14.9.4.2.1.1
The number of current established PVCs in this switch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..32000  

connConfNodeSvcs 1.3.6.1.4.1.119.2.3.14.9.4.2.1.2
The number of current established SVCs in this switch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4096  

connConfNodeSoftPvcs 1.3.6.1.4.1.119.2.3.14.9.4.2.1.3
The number of current established Soft PVPCs/PVCCs in this switch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4096  

connConfNodeTrafClear 1.3.6.1.4.1.119.2.3.14.9.4.2.1.4
Set allClear (1) to clear all traffic registration information. If noOperation (2) is written, nothing will be performed. The value at read is always noOperation (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER allClear(1), noOperation(2)  

connConfNodeTrafs 1.3.6.1.4.1.119.2.3.14.9.4.2.1.5
The number of traffic registrations which are being set in the switch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1024  

connConfNodeCompleteSvcs 1.3.6.1.4.1.119.2.3.14.9.4.2.1.6
The number of SVC complete calls
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

connConfNodeUnCompleteSvcs 1.3.6.1.4.1.119.2.3.14.9.4.2.1.7
The number of SVC incomplete calls
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

connConfIfTable 1.3.6.1.4.1.119.2.3.14.9.4.2.2
The table is used to show the information of current established connections on the interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnConfIfEntry

connConfIfEntry 1.3.6.1.4.1.119.2.3.14.9.4.2.2.1
Entry of connConfIfTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnConfIfEntry  

connConfIfPvcs 1.3.6.1.4.1.119.2.3.14.9.4.2.2.1.1
The number of current established PVCs on the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16384  

connConfIfSvcs 1.3.6.1.4.1.119.2.3.14.9.4.2.2.1.2
The number of current established SVCs on the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4096  

connConfIfSoftPvcs 1.3.6.1.4.1.119.2.3.14.9.4.2.2.1.3
The number of current established Soft PVPCs/PVCCs on the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4096  

connRoute 1.3.6.1.4.1.119.2.3.14.9.4.3
OBJECT IDENTIFIER    

connRouteOpe 1.3.6.1.4.1.119.2.3.14.9.4.3.1
OBJECT IDENTIFIER    

connRouteOpeStatus 1.3.6.1.4.1.119.2.3.14.9.4.3.1.1
allocate : allocate the right to operate the routing information to a manager. add : add the routing information to static routing table. delete : delete the routing information from static routing table. free : free the right to operate the routing information from a manager. +-------------+ | | +---+----+<---+ ----------->|free|<----------------- | +----+ | | | | +--------+ +----------+ | ---->|allocate| -----> |add/delete|- +--------+ +----------+
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER allocate(1), add(2), delete(3), free(4)  

connRouteOpeFailureCause 1.3.6.1.4.1.119.2.3.14.9.4.3.1.2
The result of the operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ConnRouteOpeFailureCause  

connRouteOpeAddressFormat 1.3.6.1.4.1.119.2.3.14.9.4.3.1.3
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstAtmAddressFormat  

connRouteOpeAddressLength 1.3.6.1.4.1.119.2.3.14.9.4.3.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstAtmAddressLength  

connRouteOpeAddress 1.3.6.1.4.1.119.2.3.14.9.4.3.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstAtmAddress  

connRouteOpePrimaryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstPrimaryIfIndex  

connRouteOpePrimaryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstPrimaryVPI  

connRouteOpeSecondaryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstSecondaryIfIndex  

connRouteOpeSecondaryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstSecondaryVPI  

connRouteOpeTertiaryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstSecondaryIfIndex  

connRouteOpeTertiaryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.1.11
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstSecondaryVPI  

connRouteOpeFourthryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstSecondaryIfIndex  

connRouteOpeFourthryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstSecondaryVPI  

connRouteOpeFifthryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.1.14
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstSecondaryIfIndex  

connRouteOpeFifthryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.1.15
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstSecondaryVPI  

connRouteOpeSixthryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.1.16
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstSecondaryIfIndex  

connRouteOpeSixthryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.1.17
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstSecondaryVPI  

connRouteOpeSeventhryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.1.18
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstSecondaryIfIndex  

connRouteOpeSeventhryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.1.19
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DstSecondaryVPI  

connRouteTable 1.3.6.1.4.1.119.2.3.14.9.4.3.2
This table is used to show the static routing table for SVC.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnRouteEntry

connRouteEntry 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1
Entry of connRouteTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnRouteEntry  

connRouteType 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.1
The value of this object shows the routing type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER static(1), dynamic(2)  

connRoutePrimaryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstPrimaryIfIndex  

connRoutePrimaryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstPrimaryVPI  

connRouteSecondaryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstSecondaryIfIndex  

connRouteSecondaryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.5
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstSecondaryVPI  

connRouteTertiaryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.6
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstSecondaryIfIndex  

connRouteTertiaryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.7
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstSecondaryVPI  

connRouteFourthryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.8
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstSecondaryIfIndex  

connRouteFourthryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.9
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstSecondaryVPI  

connRouteFifthryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.10
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstSecondaryIfIndex  

connRouteFifthryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.11
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstSecondaryVPI  

connRouteSixthryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.12
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstSecondaryIfIndex  

connRouteSixthryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.13
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstSecondaryVPI  

connRouteSeventhryIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.14
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstSecondaryIfIndex  

connRouteSeventhryVPI 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.15
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DstSecondaryVPI  

connRoutePrimaryStatus 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.16
Operational status of the primary routing. If the primary route of the routing table of the equipment is valid, enable(2), if not valid, disable(1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

connRoutePrimaryCause 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.17
Cause of the switching from the primary route.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), other(1), outOfService(2), testing(3), lineInterface-Down(4), lineInterface-Failure(5), sw-Engine-Failure(6), sw-Engine-SwapOUT(7), notInstalled(99)  

connRouteAtmAddressFormat 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.18
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DstAtmAddressFormat  

connRouteAtmAddressLength 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.19
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DstAtmAddressLength  

connRouteAtmAddress 1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.20
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DstAtmAddress  

connSoftPvcIndexNext 1.3.6.1.4.1.119.2.3.14.9.4.4
This object returns the empty index of the call management table, required to access to connSoftPvcTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..128  

connSoftPvcTable 1.3.6.1.4.1.119.2.3.14.9.4.5
This table include all entries to Soft-PVPC/PVCC currently available between the lines or the line and CPU port of the switch. Also, this table is used to set or delete Soft-PVPC/PVCC. The operable connection form between Soft-PVPC/PVCC is bi- directional point-to-point only. The procedure to set the connection is as follows: 1. Acquire connSoftPvcIndex To set the connection, read connSoftPvcIndexNext and obtain an index of the Soft-PVPC/PVCC table. The index must be managed by NMS. (The index is required to take an action to the connection.) 2. Set createAndWait Set connSoftPvcRowStatus to CreateAndWait, using the obtained connSoftPvcIndex as index. If the agent will set the parameter for the Soft-PVPC/PVCC setting to the default value and make connSoftRowStatus to notReady. However, the same manager cannot create another row while creating a row (the status of the row is notRedy or notInService). 3. Get the default value Get the default value of the object which serves as parameter for the connection setting. (The agent shall return -1 if it does not have a default value.) Default values are as follows: connSoftPvcTopology bi-directional-VCC(2) connSoftPvcTrafficType traffic-UBR(5) connSoftPvcEndpointType calling(1) connSoftPvcRetry 2 connSoftPvcSrcAtmAddressFormat nsap(2) connSoftPvcSrcAtmAddressLength None connSoftPvcSrcAtmAddress 0 length string connSoftPvcSrcIfIndex None connSoftPvcSrcVPI None connSoftPvcSrcVCI None connSoftPvcDstAtmAddressFormat nsap(2) connSoftPvcDstAtmAddressLength None connSoftPvcDstAtmAddress 0 length string connSoftPvcDstIfIndex None connSoftPvcDstVPI None connSoftPvcDstVCI None connSoftPvcSrcFifoIndex 0 connSoftPvcDstFifoIndex 0 connSoftPvcNodeKind model5(1) connSoftPvcSrcParam1 off(1) connSoftPvcDstParam1 off(1) connSoftPvcSrcParam2 0 length string connSoftPvcDstParam2 0 length string connSoftPvcSrcParam3 -1 connSoftPvcDstParam3 -1 connSoftPvcSrcParam4 -1 connSoftPvcDstParam4 -1 connSoftPvcSrcParam5 -1 connSoftPvcDstParam5 -1 connSoftPvcSrcParam6 off(2) connSoftPvcDstParam6 off(2) connSoftPvcSrcParam7 None (not installed) connSoftPvcDstParam7 None (not installed) 4. Set parameter If a parameter does not have a default value, or the default value should not be used, set the parameter to a value. If all parameters are set, the agent shall make connSoftPvcRowStatus to notInService. 5. Set active By doing so, the agent checks parameters, resources and establishes the connection. 6. Get connSoftPvcRowStatus If connSoftPvcRowStatus is active, the connection setting completed successfully, if notInService, the connection setting failed. For the cause, refer to connSoftPvcCause. (Note) When the connection setting has failed, if the connection is not released, the row will remain. 7. Get connSoftPvcRestRetry Remaining counts of retry are contained. If it is positive value, the retry is in progress. If connSoftPvcRestRetry is 0, the retry completed. The result of the connection setting should be seen, when this object is 0. -1 means that infinite retry is in progress. ***Special pattern*** (1) If connSoftPvcTopology is bi-directional-VPC, set connSoftPvcSrcVCI, connSoftPvcDstVCI to 0. The procedure to release the connection is as follows: 1. Set 'destroy' Set connSoftPvcRowStatus to 'destroy', using connSoftPvcIndex of the connection to be deleted as index. The agent will delete the connection, referring to it. (Note) 'destroy' can also be set during the bypass processing. 2. Get the result If the connection is deleted, 'get' of connSoftPvcTable of the designated index becomes NoSuchName. The bypass processing of connection 1. Set notInService When the agent executes the bypass processing of connection, set connSoftPvcRowStatus to notInService, and then establish the connection. 2. Get connSoftPvcRowStatus If connSoftPvcRowStatus is 'active', the bypass connection setting has completed successfully. If connSoftPvcRowStatus remains 'notInService', the connection setting has failed. Others 1. The cut and recovery processing of connection is performed, following the delete and set procedures of the concerned connection. Each procedure is as stated before.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnSoftPvcEntry

connSoftPvcEntry 1.3.6.1.4.1.119.2.3.14.9.4.5.1
Entry of ATMSoft-PVPC/PVCC connection
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnSoftPvcEntry  

connSoftPvcIndex 1.3.6.1.4.1.119.2.3.14.9.4.5.1.1
The value of this object is equal to the connSoftPvcIndexNext. 1 - 128 : Soft PVPCs/PVCCs
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..128  

connSoftPvcTopology 1.3.6.1.4.1.119.2.3.14.9.4.5.1.2
Topology of the Connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bi-directional-VCC(2), bi-directional-VPC(4)  

connSoftPvcTrafficType 1.3.6.1.4.1.119.2.3.14.9.4.5.1.3
Traffic Type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER traffic-CBR(1), traffic-rt-VBR(2), traffic-nrt-VBR(3), traffic-ABR(4), traffic-UBR(5)  

connSoftPvcEndpointType 1.3.6.1.4.1.119.2.3.14.9.4.5.1.4
Type of Endpoint.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER calling(1), called(2)  

connSoftPvcRetry 1.3.6.1.4.1.119.2.3.14.9.4.5.1.5
Number of retry. 0 - 15 : Number of retry -1 : Infinite retry
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15 | -1  

connSoftPvcSrcAtmAddressFormat 1.3.6.1.4.1.119.2.3.14.9.4.5.1.6
AtmAdress format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  ConnSoftPvcSrcAtmAddressFormat  

connSoftPvcSrcAtmAddressLength 1.3.6.1.4.1.119.2.3.14.9.4.5.1.7
The valid bit length of connSoftPvcSrcAtmAddress. The value(-1) is read-only. The value(4..160) must be a multiple of 4.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..160 | -1  

connSoftPvcSrcAtmAddress 1.3.6.1.4.1.119.2.3.14.9.4.5.1.8
NodeId of source node. Its maximum length is 13 bytes. This object length is 20 bytes in case AtmAddress is setting. If the last semi OCTET is invalid, it is padded with 0xf. The value of size(0) is read-only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

connSoftPvcSrcIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.5.1.9
The number of the calling line. (ifIndex of ifEntry)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99 | -1  

connSoftPvcSrcVPI 1.3.6.1.4.1.119.2.3.14.9.4.5.1.10
VPI value of the calling line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connSoftPvcSrcVCI 1.3.6.1.4.1.119.2.3.14.9.4.5.1.11
VCI value of the calling line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connSoftPvcDstAtmAddressFormat 1.3.6.1.4.1.119.2.3.14.9.4.5.1.12
AtmAdress format.
Status: mandatory Access: read-write
OBJECT-TYPE    
  ConnSoftPvcDstAtmAddressFormat  

connSoftPvcDstAtmAddressLength 1.3.6.1.4.1.119.2.3.14.9.4.5.1.13
The valid bit length of connSoftPvcDstAtmAddress. The value(-1) is read-only. The value(4..160) must be a multiple of 4.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..160 | -1  

connSoftPvcDstAtmAddress 1.3.6.1.4.1.119.2.3.14.9.4.5.1.14
NodeId of destination node. Its maximum length is 13 bytes. This object length is 20 bytes in case AtmAddress is setting. If the last semi OCTET is invalid, it is padded with 0xf. The value of size(0) is read-only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..20)  

connSoftPvcDstIfIndex 1.3.6.1.4.1.119.2.3.14.9.4.5.1.15
The number of the called line. (ifIndex of ifEntry)65 is GateWay.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..99 | -1  

connSoftPvcDstVPI 1.3.6.1.4.1.119.2.3.14.9.4.5.1.16
VPI value of the called line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connSoftPvcDstVCI 1.3.6.1.4.1.119.2.3.14.9.4.5.1.17
VCI value of the called line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connSoftPvcRowStatus 1.3.6.1.4.1.119.2.3.14.9.4.5.1.18
It is used from the manager to order the setting method of the Soft PVC connection. It is used from the agent side to return the result of the connection setting request. - 'active', which indicates that the conceptual row is available for use by the managed device; - 'notInService', which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device; - 'notReady', which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device; - 'createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have it available for use by the managed device; - 'createAndWait', which is supplied by a management station wishing to create a new instance of a conceptual row but not to have it available for use by the managed device; and, - 'destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)  

connSoftPvcCause 1.3.6.1.4.1.119.2.3.14.9.4.5.1.19
Object to indicate the result of the connection setting.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rowExisting(1), vpivciSrcBusy(2), vpivciDstBusy(3), vpivciOutOfRange(4), rateSrcOverFlow(5), rateDstOverFlow(6), dataTableFull(7), inconsistentVPVC(8), lineDiagnosis(9), missMatchTrfType(10), illegalSrcFileName(11), illegalDstFileName(12), lineOutOfOrder(13), illegalSrcShaper(14), illegalOperation(15), parameterIsNotEnough(16), diagnostics(17), otherFailure(18), illegalSrcRateForUPC(19), noCevc(20), noDlci(21), noSrcShaperForGateway(22), noPvcSrcShaperForGateway(23), missMatchTrfTypeSrcShaperForGateway(24), insusfficientPCRofProfile(25)  

connSoftPvcRestRetry 1.3.6.1.4.1.119.2.3.14.9.4.5.1.20
Remaining number of retry 0 - 15 : Remaining number of retry -1 : Infinite retry in progress
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..15 | -1  

connSoftPvcSrcFifoIndex 1.3.6.1.4.1.119.2.3.14.9.4.5.1.21
Designate the Shaper number of the calling line. If the Shaping is not performed, designate 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

connSoftPvcDstFifoIndex 1.3.6.1.4.1.119.2.3.14.9.4.5.1.22
Designate the Shaper number of the called line. If the Shaping is not performed, designate 0. However, if the called sw is not furnished with the shaping function, this value has no meaning. Since it cannot be recognized if this value is set on the called side, the value is regarded as 'the value set by the calling side'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..16  

connSoftPvcNodeKind 1.3.6.1.4.1.119.2.3.14.9.4.5.1.23
Designate/indicate the machine type on the called side.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER model5(1), model7(2), model5E(3)  

connSoftPvcSrcParam1 1.3.6.1.4.1.119.2.3.14.9.4.5.1.24
UPC mode of the calling line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), mode1(2), mode2(3), mode3(4), mode4(5), mode5(6)  

connSoftPvcDstParam1 1.3.6.1.4.1.119.2.3.14.9.4.5.1.25
UPC mode of the called line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), mode1(2), mode2(3), mode3(4), mode4(5), mode5(6)  

connSoftPvcSrcParam2 1.3.6.1.4.1.119.2.3.14.9.4.5.1.26
Profile name of Forward. If nothing is designated, the string of size(0) is designated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..10|0)  

connSoftPvcDstParam2 1.3.6.1.4.1.119.2.3.14.9.4.5.1.27
Profile name of Backward. If nothing is designated, the string of size(0) is designated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..10|0)  

connSoftPvcSrcParam3 1.3.6.1.4.1.119.2.3.14.9.4.5.1.28
PCR[cell/s] of Forward. If the value is invalid, -1 is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connSoftPvcDstParam3 1.3.6.1.4.1.119.2.3.14.9.4.5.1.29
PCR[cell/s] of Backward. If the value is invalid, -1 is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connSoftPvcSrcParam4 1.3.6.1.4.1.119.2.3.14.9.4.5.1.30
SCR[cell/s] of Forward. If the value is invalid, -1 is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connSoftPvcDstParam4 1.3.6.1.4.1.119.2.3.14.9.4.5.1.31
SCR[cell/s] of Backward. If the value is invalid, -1 is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connSoftPvcSrcParam5 1.3.6.1.4.1.119.2.3.14.9.4.5.1.32
MBS[cell] of Forward. If the value is invalid, -1 is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connSoftPvcDstParam5 1.3.6.1.4.1.119.2.3.14.9.4.5.1.33
MBS[cell] of Backward. If the value is invalid, -1 is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connSoftPvcSrcParam6 1.3.6.1.4.1.119.2.3.14.9.4.5.1.34
EPD(Early Packet Discard) of Forward. Indicate if the discard processing in the unit of AAL5 packet should be performed or not when the threshold is exceeded. If the value is invalid, off(2) is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

connSoftPvcDstParam6 1.3.6.1.4.1.119.2.3.14.9.4.5.1.35
EPD(Early Packet Discard) of Backward. Indicate if the discard processing in the unit of AAL5 packet should be performed or not when the threshold is exceeded. If the value is invalid, off(2) is indicated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

connSoftPvcSrcParam7 1.3.6.1.4.1.119.2.3.14.9.4.5.1.36
MCR[cell/s]. Not supported here.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

connSoftPvcDstParam7 1.3.6.1.4.1.119.2.3.14.9.4.5.1.37
MCR[cell/s]. Not supported here.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

connSoftPvcEstablishedSrcInfTable 1.3.6.1.4.1.119.2.3.14.9.4.6
The table regarding the calling node of the Soft PVPC/PVCC established as called side office by the local node
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnSoftPvcEstablishedSrcInfEntry

connSoftPvcEstablishedSrcInfEntry 1.3.6.1.4.1.119.2.3.14.9.4.6.1
The entry of the calling side node information of the Soft PVPC/PVCC established as the called side office by the local node
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnSoftPvcEstablishedSrcInfEntry  

connSoftPvcEstablishedSrcInf 1.3.6.1.4.1.119.2.3.14.9.4.6.1.1
The calling node information of the Soft PVPC/PVCC established as called side office by the node. The structure of the entry is as follows struct { long SrcAtmAddressFormat; long SrcAtmAddressLength; char SrcAtmAddress[20]; }; (*1) 'long' data should be stored with 'big endian'. (*2) For SrcAtmAddress data, if it is less than 20 byte, the data padded by '0xf' shall be stored. This information is divided into up to 32 pieces, and each piece is put into the head 4 bytes (count) of an entry. The data which contains the number of the entries is described below. +-----------------+ | count | (= n) +-----------------+ | EstSrcInf 1 | |.................| | EstSrcInf 2 | |.................| | . | | . | | . | |.................| | EstSrcInf n | ( 1 <= n <= 32 ) +-----------------+
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

connSoftPvcEstSrcInfIndex 1.3.6.1.4.1.119.2.3.14.9.4.6.1.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnSoftPvcEstSrcInfIndex  

connOam 1.3.6.1.4.1.119.2.3.14.9.4.7
OBJECT IDENTIFIER    

connOamOpe 1.3.6.1.4.1.119.2.3.14.9.4.7.1
OBJECT IDENTIFIER    

connOamOpeStatus 1.3.6.1.4.1.119.2.3.14.9.4.7.1.1
Used to set/delete OAM End-point, Connecting-point.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER allocate(1), add(2), delete(3), free(4)  

connOamOpeCause 1.3.6.1.4.1.119.2.3.14.9.4.7.1.2
The result of the processing to set/delete OAM End-point, Connecting-point.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), succeed(2), parameterIsNotEnough(3), tableIsFull(4), illegalPoint(5), illegalMode(6), illegalSection(7), illegalPort(8), illegalVpiVci(9), invalidBufferType(10), noSuchConnection(11), alreadyRegistered(12), notExisting(13)  

connOamOpePoint 1.3.6.1.4.1.119.2.3.14.9.4.7.1.3
End-point / Connecting-point.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER end-point(1), connecting-point(2)  

connOamOpeMode 1.3.6.1.4.1.119.2.3.14.9.4.7.1.4
Mode. F4 (VP level)/f5 (VC level)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER f4(1), f5(2)  

connOamOpeSection 1.3.6.1.4.1.119.2.3.14.9.4.7.1.5
Point between segments/End-to-End point.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER segment(1), end-to-end(2)  

connOamOpePort1 1.3.6.1.4.1.119.2.3.14.9.4.7.1.6
Line number
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connOamOpePort2 1.3.6.1.4.1.119.2.3.14.9.4.7.1.7
Line number. Upon setting/deleting end-point, don't care about it.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connOamOpeVpi1 1.3.6.1.4.1.119.2.3.14.9.4.7.1.8
VPI.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connOamOpeVpi2 1.3.6.1.4.1.119.2.3.14.9.4.7.1.9
VPI. Upon setting/deleting end-point, don't care about it.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connOamOpeVci1 1.3.6.1.4.1.119.2.3.14.9.4.7.1.10
VCI.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connOamOpeVci2 1.3.6.1.4.1.119.2.3.14.9.4.7.1.11
VCI.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connOamTable 1.3.6.1.4.1.119.2.3.14.9.4.7.2
OAM End-point, Connecting-point indication table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnOamEntry

connOamEntry 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1
OAM End-point, Connecting-point indication entry
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnOamEntry  

connOamPort 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.1
Line number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

connOamIndex 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.2
OAM End-point / Connecting-point Index.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..144  

connOamContrastPort 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.3
Line number of the opposite line. For End-point, -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connOamVpi 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.4
VPI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connOamContrastVpi 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.5
Opposite VPI. For End-point, -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connOamVci 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.6
VCI. For the f4 level, -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connOamContrastVci 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.7
Opposite VCI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connOamPoint 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.8
End-point / Connecting-point.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER end-point(1), connecting-point(2)  

connOamMode 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.9
Mode. F4 (VP level)/f5 (VC level).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER f4(1), f5(2)  

connOamSection 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.10
Point between segments/End-to-End point.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER segment(1), end-to-end(2)  

connOamStatus 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.11
Receive status of end-point.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), normal(2), receive-AIS(3), receive-RDI(4), failure(5)  

connOamDefectType 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.12
Fault cause in the receive cell. For Connecting-point, return 'normal (1)'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), los(2), lof(3), loc(4), ais-path(5), ais-section(6), yellow-section(7), yellow-path(8), lop(9), ais(10), payload-all-one(11), rai(12), oof(13), idle(14), rdi(15), plcp-oof(16), plcp-lof(17), plcp-yellow(18), red(19)  

connOamDefectNodeID 1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.13
Node ID of the Switch which sends alarm transfer cells. For connecting-point, return '0 length string'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(13)  

connLoop 1.3.6.1.4.1.119.2.3.14.9.4.8
OBJECT IDENTIFIER    

connLoopOpe 1.3.6.1.4.1.119.2.3.14.9.4.8.1
OBJECT IDENTIFIER    

connLoopOpeStatus 1.3.6.1.4.1.119.2.3.14.9.4.8.1.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER allocate(1), action(2), endtest(3), free(4)  

connLoopOpeCause 1.3.6.1.4.1.119.2.3.14.9.4.8.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER succeed(1), abort(2), other(3), vpivciOutOfRange(4), parameterFailed(5), admindown(6), nonePkg(7), noneBuffer2(8), lineLoopback(9), resetSlot(10), noneLoopBackId(11), execute(12)  

connLoopOpeMode 1.3.6.1.4.1.119.2.3.14.9.4.8.1.3
F4 (VP level)/f5 (VC level).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER f4(1), f5(2)  

connLoopOpeBase 1.3.6.1.4.1.119.2.3.14.9.4.8.1.4
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER segment(1), end-end(2)  

connLoopOpeLoopBackPointNodeId 1.3.6.1.4.1.119.2.3.14.9.4.8.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(16)  

connLoopOpeCorrelationTag 1.3.6.1.4.1.119.2.3.14.9.4.8.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(4)  

connLoopOpeCount 1.3.6.1.4.1.119.2.3.14.9.4.8.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..16  

connLoopOpePort 1.3.6.1.4.1.119.2.3.14.9.4.8.1.8
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connLoopOpeVpi 1.3.6.1.4.1.119.2.3.14.9.4.8.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connLoopOpeVci 1.3.6.1.4.1.119.2.3.14.9.4.8.1.10
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connLoopOpeNormalEndCount 1.3.6.1.4.1.119.2.3.14.9.4.8.1.11
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connLoopOpeAbnormalEndCount 1.3.6.1.4.1.119.2.3.14.9.4.8.1.12
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connLoopOpeAbortCount 1.3.6.1.4.1.119.2.3.14.9.4.8.1.13
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connLoopOpeLoopBackPointIdLength 1.3.6.1.4.1.119.2.3.14.9.4.8.1.14
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connProfile 1.3.6.1.4.1.119.2.3.14.9.4.9
OBJECT IDENTIFIER    

connProfileIndexNext 1.3.6.1.4.1.119.2.3.14.9.4.9.1
Shows the empty index value of connProfileTable(including row of notReady, notInService). If the number of profiles reaches the registration limit, 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ConnProfileIndex  

connProfileTable 1.3.6.1.4.1.119.2.3.14.9.4.9.2
Table to set/indicate the profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnProfileEntry

connProfileEntry 1.3.6.1.4.1.119.2.3.14.9.4.9.2.1
Entry of connProfileTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnProfileEntry  

connProfileIndex 1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.1
Index value of connProfileTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnProfileIndex  

connProfileRowStatus 1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.2
Used to control rows of the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)  

connProfileCause 1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.3
The result of Profile setting processing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rowExisting(1), otherFailure(2), inconsistentEpd(3), parameterNotEnough(4), alreadyExist(5), duplicateName(6), inconsistentRate(7)  

connProfileTrafficType 1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.4
Traffic Type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER traffic-CBR(1), traffic-rt-VBR(2), traffic-nrt-VBR(3), traffic-ABR(4), traffic-UBR(5)  

connProfileName 1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.5
Profile name. Available characters: alphanumeric characters 0 length string is only read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0|1..10)  

connProfileParam1 1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.6
For ph1/2-buffer, peek cell rate [cell/sec]. If it is invalid, -1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1 | 1..1412830  

connProfileParam2 1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.7
For ph1/2-buffer, Sustainable cell rate [cell/sec]. Only nrt-VBR, and rt-VBR are valid. If it is invalid, -1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1 | 1..1412830  

connProfileParam3 1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.8
For ph1/2-buffer, Maximum burst size [cell]. Only nrt-VBR, and rt-VBR are valid. If it is invalid, -1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1 | 1..1412830  

connProfileParam4 1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.9
For ph1/2-buffer, EPD function flag. If it is other than ABR, UBR, off, only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

connProfileName2Index 1.3.6.1.4.1.119.2.3.14.9.4.9.3
Equivalent to connProfileName
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0|1..10)  

connProfileName2IndexResult 1.3.6.1.4.1.119.2.3.14.9.4.9.4
Shows the index of the row whose connProfileRowStatus in connProfileTable, corresponding to connProfileName2Index, is active. If the corresponding row does not exist, 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ConnProfileIndex  

connSvcTable 1.3.6.1.4.1.119.2.3.14.9.4.10
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnSvcEntry

connSvcEntry 1.3.6.1.4.1.119.2.3.14.9.4.10.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnSvcEntry  

connSvcIndex 1.3.6.1.4.1.119.2.3.14.9.4.10.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

connSvcInf 1.3.6.1.4.1.119.2.3.14.9.4.10.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  Opaque  

connCe 1.3.6.1.4.1.119.2.3.14.9.4.11
OBJECT IDENTIFIER    

connCeVc 1.3.6.1.4.1.119.2.3.14.9.4.11.1
OBJECT IDENTIFIER    

connCeVcTable 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnCeVcEntry

connCeVcEntry 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnCeVcEntry  

connCeVcPort 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.1
Line number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

connCeVcVci 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.2
VCI value.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 32..383  

connCeVcRowStatus 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.3
Used to control rows of the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)  

connCeVcCause 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.4
The result of CEVC setting processing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rowExisting(1), otherFailure(2), parameterNotEnough(3), illegalpkg(4), vcsOverFllow(5), tssOverFllow(6), alreadyAssignedTs(7), inconsistentTss(8), illegalTimeslot(9), illegalPort(10), illegalVci(11), illegalUpPartialFillSize(12), illegalDownPartialFillSize(13), illegalCdvt(14)  

connCeVcDirection 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bi(1), up(2), down(3)  

connCeVcUpPartialFillSize 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1 | 0..47  

connCeVcDownPartialFillSize 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.7
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1 | 0..47  

connCeVcCondition 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.8
Condtion date.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1 | 0..255  

connCeVcCDVT 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.9
CDVT value. +----------------------+----------+------------+ |pkg type| str mode |CDVT range| unit of | | | | | setting | ================================================ | CE-J2 | unstructure | 1..73 | 125sec | | +-------------+----------+------------+ | | structure | 1..7218 | 125sec | +--------+-------------+----------+------------+ | CE-DS1 | unstructure | 1..255 | 165.8sec | | +-------------+----------+------------+ | | structure | 1..191 | 125sec | +--------+-------------+----------+------------+ | CE-E1 | unstructure | 1..255 | 124.5sec | | +-------------+----------+------------+ | | structure | 1..255 | 125sec | +--------+-------------+----------+------------+ | CE-DS3 | unstructure | 1..255 | 5.7sec | +--------+-------------+----------+------------+
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1 | 1..7218  

connCeVcUpPCR 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.10
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER -1 | 0..118979  

connCeVcDownPCR 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.11
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER -1 | 0..118979  

connCeVcUpTimeSlot1 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.12
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connCeVcDownTimeSlot1 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connCeVcUpTimeSlot2 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.14
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connCeVcDownTimeSlot2 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.15
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connCeVcUpTimeSlot3 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.16
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connCeVcDownTimeSlot3 1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.17
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

connFr 1.3.6.1.4.1.119.2.3.14.9.4.12
OBJECT IDENTIFIER    

connFrDlci 1.3.6.1.4.1.119.2.3.14.9.4.12.1
OBJECT IDENTIFIER    

connFrDlciTable 1.3.6.1.4.1.119.2.3.14.9.4.12.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnFrDlciEntry

connFrDlciEntry 1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1
Entry of connFrDlciTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnFrDlciEntry  

connFrDlciPort 1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.1
Line number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..64  

connFrDlciIndex 1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.2
DLCI number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 16..1007  

connFrDlciRowStatus 1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.3
Used to control rows of the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)  

connFrDlciCause 1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rowExisting(1), otherFailure(2), noFrProfile(3), inconsistentInterWorking(4), totalCIROverFlow(5), lineDiagnosticsFailure(6), illegalPort(7), illegalDlci(8), pvcsOverFlow(9)  

connFrDlciFrProfile 1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0|1..10)  

connFrDlciPCR 1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.6
Peak Cell Rate[cell/sec].
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connFrDlciSCR 1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.7
Sustainable Cell Rate[cell/sec].
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connFrDlciMBS 1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.8
Maximum Burst Size[cell].
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connFrProfile 1.3.6.1.4.1.119.2.3.14.9.4.12.2
OBJECT IDENTIFIER    

connFrProfileIndexNext 1.3.6.1.4.1.119.2.3.14.9.4.12.2.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  ConnFrProfileIndex  

connFrProfileTable 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnFrProfileEntry

connFrProfileEntry 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1
Entry of connFrProfileTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnFrProfileEntry  

connFrProfileIndex 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.1
Index of connFrProfileTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnFrProfileIndex  

connFrProfileRowStatus 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.2
Used to control rows of the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6)  

connFrProfileCause 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.3
The result of Frprofile setting processing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rowExisting(1), otherFailure(2), parameterNotEnough(3), alreadyExist(4), duplicateName(5)  

connFrProfileName 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.4
Frprofile name. Available characters: alphanumeric characters 0 length string is only read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0|1..10)  

connFrProfileInterworkingType 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.5
Interworking Type
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER network(1), service(2)  

connFrProfileCIR 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.6
CIR value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER -1 | 1..1984  

connFrProfileDEtoCLP 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.7
DE to CLP mapping mode
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mode1(1), mode2(2)  

connFrProfileCLPValue 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.8
CLP Value. It's valid when connFrProfileDEtoCLP is mode2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), off(3)  

connFrProfileCLPtoDE 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.9
CLP to DE mapping mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER mode1(1), mode2(2)  

connFrProfileDEValue 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.10
DE Value. It's valid when connFrProfileInterworkingType is service and connFrProfileCLPtoDE is mode2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), on(2), off(3)  

connFrProfileCapsulationMode 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.11
Protocol encapsulation mode. It's valid when connFrProfileInterworkingType is service.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), transparent(2), translation(3)  

connFrProfileCongestionMode 1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.12
Congestion indication(Forward) mode. It's valid when connFrProfileInterworkingType is service.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), mode1(2), mode2(3)  

connFrProfileName2Index 1.3.6.1.4.1.119.2.3.14.9.4.12.2.3
Equivalent to connProfileName.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0|1..10)  

connFrProfileName2IndexResult 1.3.6.1.4.1.119.2.3.14.9.4.12.2.4
Shows the index of the row whose connFrProfileRowStatus in connFrProfileTable, corresponding to connFrProfileName2Index, is active. If the corresponding row does not exist, 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ConnFrProfileIndex  

perfTrapEnable 1.3.6.1.4.1.119.2.3.14.9.5.1
This object is used for disabling/enabling trap messages regarding the enterprise specific traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

perfIfTable 1.3.6.1.4.1.119.2.3.14.9.5.2
Table for showing the result of the performance monitoring per line of the equipment. Up to 64 tables are available for entry. Every line whose traffic is managed per line is provided with an entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PerfIfEntry

perfIfEntry 1.3.6.1.4.1.119.2.3.14.9.5.2.1
Entry of the line performance monitoring.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PerfIfEntry  

perfIfIndex 1.3.6.1.4.1.119.2.3.14.9.5.2.1.1
Line number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

perfIfReceivedCells 1.3.6.1.4.1.119.2.3.14.9.5.2.1.2
The Number of the receive cells of line port. (64 bit applicable)
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

perfIfReceivedCellsCounters 1.3.6.1.4.1.119.2.3.14.9.5.2.1.3
The Number of the receive cells of line port. (32 bit applicable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

perfIfTransmittedCells 1.3.6.1.4.1.119.2.3.14.9.5.2.1.4
The Number of the transmit cells of line port. (64 bit applicable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

perfIfTransmittedCellsCounters 1.3.6.1.4.1.119.2.3.14.9.5.2.1.5
The Number of the transmit cells of line port. (32 bit applicable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

perfIfMisDelivdCells 1.3.6.1.4.1.119.2.3.14.9.5.2.1.8
The Number of the undefined cells of line port. (64 bit applicable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

perfIfMisDelivdCellsCounters 1.3.6.1.4.1.119.2.3.14.9.5.2.1.9
The Number of the undefined cells of line port. (32 bit applicable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

perfIfThresholdExcessCells 1.3.6.1.4.1.119.2.3.14.9.5.2.1.10
Number of the threshold excess cells (64 bit applicable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

perfIfThresholdExcessCellsCounters 1.3.6.1.4.1.119.2.3.14.9.5.2.1.11
Number of the threshold excess cells (32 bit applicable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

perfIfUpcErrorCells 1.3.6.1.4.1.119.2.3.14.9.5.2.1.12
Number of the UPC error cells (64 bit applicable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

perfIfUpcErrorCellsCounters 1.3.6.1.4.1.119.2.3.14.9.5.2.1.13
Number of the UPC error cells (32 bit applicable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

perfIfSlotTable 1.3.6.1.4.1.119.2.3.14.9.5.3
Table for showing the number of cells of the traffic and performance per line card of the equipment. Up to 16 tables are available for entry. Every line whose traffic is managed per slot is provided with an entry. The object which becomes invalid by the line card is always 0.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PerfIfSlotEntry

perfIfSlotEntry 1.3.6.1.4.1.119.2.3.14.9.5.3.1
Entry of traffic/performance per line card.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PerfIfSlotEntry  

perfIfSlotReceivedCells 1.3.6.1.4.1.119.2.3.14.9.5.3.1.1
The number of receive cells.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

perfIfSlotTransmittedCells 1.3.6.1.4.1.119.2.3.14.9.5.3.1.2
The number of transmit cells.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

perfIfSlotInDropCells 1.3.6.1.4.1.119.2.3.14.9.5.3.1.3
The number of receive drop cells.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

perfIfSlotReceivedCellsCounters 1.3.6.1.4.1.119.2.3.14.9.5.3.1.5
The number of receive cells.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

perfIfSlotTransmittedCellsCounters 1.3.6.1.4.1.119.2.3.14.9.5.3.1.6
The number of transmit cells.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

perfIfSlotInDropCellsCounters 1.3.6.1.4.1.119.2.3.14.9.5.3.1.7
The number of receive drop cells.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

perfIfSlotHCThresholdExcessCells 1.3.6.1.4.1.119.2.3.14.9.5.3.1.9
The number of threshold excess cells
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

perfIfSlotThresholdExcessCells 1.3.6.1.4.1.119.2.3.14.9.5.3.1.10
The number of threshold excess cells
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

perfIfSlotHCUpcErrorCells 1.3.6.1.4.1.119.2.3.14.9.5.3.1.11
Number of UPC error cells.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

perfIfSlotUpcErrorCells 1.3.6.1.4.1.119.2.3.14.9.5.3.1.12
Number of UPC error cells.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

perfIfPhysTable 1.3.6.1.4.1.119.2.3.14.9.5.4
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PerfIfPhysEntry

perfIfPhysEntry 1.3.6.1.4.1.119.2.3.14.9.5.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PerfIfPhysEntry  

perfIfPhysPort 1.3.6.1.4.1.119.2.3.14.9.5.4.1.1
Line number.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCHecErorrs 1.3.6.1.4.1.119.2.3.14.9.5.4.1.2
Number of HEC error cells(64 bit applicable). On the line card other than OC12, J2 and PR-1.5M, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysHecErorrs 1.3.6.1.4.1.119.2.3.14.9.5.4.1.3
Number of HEC error cells(32 bit applicable). On the line card other than OC12, J2 and PR-1.5M, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCHecDropCells 1.3.6.1.4.1.119.2.3.14.9.5.4.1.4
Number of uncorrectable HEC error cells(64 bit applicable). On the line card other than OC3, OC12, OC12PMC, J2, PR-1.5, DS3, E3, DS1 and E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysHecDropCells 1.3.6.1.4.1.119.2.3.14.9.5.4.1.5
Number of uncorrectable HEC error cells(32 bit applicable). On the line card other than OC3, OC12, OC12PMC, J2, PR-1.5, DS3, E3, DS1 and E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCB1Errors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.6
Number of B1 errors(64 bit applicable). On the line card other than OC3, OC12, OC12PMC, DS3, E3, DS1 and E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysB1Errors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.7
Number of B1 errors(32 bit applicable). On the line card other than OC3, OC12, OC12PMC, DS3, E3, DS1 and E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCB2Errors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.8
Number of B2 errors(64 bit applicable). On the line card other than OC3, OC12 and OC12PMC, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysB2Errors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.9
Number of B2 errors(32 bit applicable). On the line card other than OC3, OC12 and OC12PMC, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCB3Errors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.10
Number of B3 errors(64 bit applicable). On the line card other than OC3, OC12 and OC12PMC, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysB3Errors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.11
Number of B3 errors(32 bit applicable). On the line card other than OC3, OC12 and OC12PMC, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCPathFEBEs 1.3.6.1.4.1.119.2.3.14.9.5.4.1.12
Number of Path FEBEs(64 bit applicable). On the line card other than OC3, OC12 and OC12PMC, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysPathFEBEs 1.3.6.1.4.1.119.2.3.14.9.5.4.1.13
Number of Path FEBEs(32 bit applicable). On the line card other than OC3, OC12 and OC12PMC, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCLineFEBEs 1.3.6.1.4.1.119.2.3.14.9.5.4.1.14
Number of Line (Section) FEBEs(64 bit applicable). On the line card other than OC3, OC12 and OC12PMC, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysLineFEBEs 1.3.6.1.4.1.119.2.3.14.9.5.4.1.15
Number of Line (Section) FEBEs(32 bit applicable). On the line card other than OC3, OC12 and OC12PMC, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCFramingErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.16
Number of Framing errors(64 bit applicable). On the line card other than DS1, E1, DS3 and E3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysFramingErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.17
Number of Framing errors(32 bit applicable). On the line card other than DS1, E1, DS3 and E3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCReceivedCells 1.3.6.1.4.1.119.2.3.14.9.5.4.1.18
The Number of the receive cells(64 bit applicable). On the line card other than DS3, E3 and OC12PMC, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysReceivedCells 1.3.6.1.4.1.119.2.3.14.9.5.4.1.19
The Number of the receive cells(32 bit applicable). On the line card other than DS3, E3 and OC12PMC, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCTransmittedCells 1.3.6.1.4.1.119.2.3.14.9.5.4.1.20
The Number of the transmit cells(64 bit applicable). On the line card other than DS3, E3 and OC12PMC, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysTransmittedCells 1.3.6.1.4.1.119.2.3.14.9.5.4.1.21
The Number of the transmit cells(32 bit applicable). On the line card other than DS3, E3 and OC12PMC, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCIdelUnassignedCells 1.3.6.1.4.1.119.2.3.14.9.5.4.1.22
The Number of Idle/Unassigned cells(64 bit applicable). On the line card other than DS3 and E3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysIdelUnassignedCells 1.3.6.1.4.1.119.2.3.14.9.5.4.1.23
The Number of Idle/Unassigned cells(32 bit applicable). On the line card other than DS3 and E3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCFEBEErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.24
Number of FEBE errors(64 bit applicable). On the line card other than DS3, E3, DS1 and E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysFEBEErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.25
Number of FEBEs errors(32 bit applicable). On the line card other than DS3, E3, DS1 and E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCFEBEs 1.3.6.1.4.1.119.2.3.14.9.5.4.1.26
Number of FEBEs(64 bit applicable). On the line card other than DS3, E3, E1 and CE-E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysFEBEs 1.3.6.1.4.1.119.2.3.14.9.5.4.1.27
Number of FEBEs(32 bit applicable). On the line card other than DS3, E3, E1 and CE-E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCPathParityErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.28
Number of path parity errors(64 bit applicable). On the line card other than DS3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysPathParityErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.29
Number of path parity errors(32 bit applicable). On the line card other than DS3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCParityErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.30
Number of parity errors(64 bit applicable). On the line card other than DS3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysParityErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.31
Number of parity errors(32 bit applicable). On the line card other than DS3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCSEZs 1.3.6.1.4.1.119.2.3.14.9.5.4.1.32
Number of detections of Summed excessive Zero (64 bit applicable). On the line card other than DS3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysSEZs 1.3.6.1.4.1.119.2.3.14.9.5.4.1.33
Number of detections of Summed excessive Zero (32 bit applicable). On the line card other than DS3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCBitErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.34
Number of Bit errors(64 bit applicable). On the line card other than DS3 and CE-DS1(SF mode), the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysBitErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.35
Number of Bit errors(32 bit applicable). On the line card other than DS3 and CE-DS1(SF mode), the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCLcvErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.36
Number of LCV errors(64 bit applicable). On the line card other than DS3, E3, DS1, E1, FR-E1, CE-DS1, FR-DS1 and CE-E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysLcvErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.37
Number of LCV errors(32 bit applicable). On the line card other than DS3, E3, DS1, E1, FR-E1, CE-DS1, FR-DS1 and CE-E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCBip8Errors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.38
Number of BIP-8 errors(64 bit applicable). On the line card other than E3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysBip8Errors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.39
Number of BIP-8 errors(32 bit applicable). On the line card other than E3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCIecErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.40
Number of IEC errors(64 bit applicable). On the line card other than E3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysIecErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.41
Number of IEC errors(32 bit applicable). On the line card other than E3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCFramingPatternErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.42
Number of Framing pattern errors(64 bit applicable). On the line card other than E3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysFramingPatternErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.43
Number of Framing pattern errors(32 bit applicable). On the line card other than E3, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCFramingBitErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.44
Number of Framing bit errors(64 bit applicable). On the line card other than DS1, E1, FR-E1, CE-DS1, FR-DS1 and CE-E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysFramingBitErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.45
Number of Framing bit errors(32 bit applicable). On the line card other than DS1, E1, FR-E1, CE-DS1, FR-DS1 and CE-E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

perfIfPhysHCCrcErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.46
Number of CRC errors(64 bit applicable). On the line card other than DS1, E1, FR-E1, FR-DS1, CE-DS1(ESF mode) and CE-E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

perfIfPhysCrcErrors 1.3.6.1.4.1.119.2.3.14.9.5.4.1.47
Number of CRC errors(32 bit applicable). On the line card other than DS1, E1, FR-E1, FR-DS1, CE-DS1(ESF mode) and CE-E1, the value of this object is 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

scaleStatus 1.3.6.1.4.1.119.2.3.14.9.6.1
Order to execute and state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER allocate(1), install(2), backup(3), free(4)  

scaleCause 1.3.6.1.4.1.119.2.3.14.9.6.2
The result of execution.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), start(2), succeed(3), nearend(4), timeOut(5), fileNotFound(6), accessViolate(7), checksumError(8), noData(9), sbyAccessError(10)  

scaleDataType 1.3.6.1.4.1.119.2.3.14.9.6.3
Data type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER system(1), config(2), bill-cdr(3)  

scaleTarget 1.3.6.1.4.1.119.2.3.14.9.6.4
IP address of the target.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

scaleFileName 1.3.6.1.4.1.119.2.3.14.9.6.5
File name(up to 127 characters).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

scaleSwSide 1.3.6.1.4.1.119.2.3.14.9.6.6
Indicate which system of the SW-Engine.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER act(1), sby(2)  

cardStatusTable 1.3.6.1.4.1.119.2.3.14.9.7.1
Table showing the configuration information of the line card with CPU.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CardStatusEntry

cardStatusEntry 1.3.6.1.4.1.119.2.3.14.9.7.1.1
Entry of the configuration nformation of the line card with CPU.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CardStatusEntry  

cardStatusServerType 1.3.6.1.4.1.119.2.3.14.9.7.1.1.1
Indicate the types of the server installed in the line card with CPU: other (1) ...other than the below stated types LANE (2) ARP (4) NHRP (8) MPOA (16) If more than one server type is installed, return the sum of their values. e.g. Only NHRP is installed -- ARP and NHRP are installed -- LANE, ARP and NHRP are installed -- -- -- --
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cardStatusRevision 1.3.6.1.4.1.119.2.3.14.9.7.1.1.2
The revision of the software installed in the line card with CPU. e.g., ...X means the number of revision. Software Version X.X(X) Boot ROM Version KXX
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cardStatusMateSlotNumber 1.3.6.1.4.1.119.2.3.14.9.7.1.1.3
The slot number of the card with double configuration (including itself). If it is single configuration/although it is of double configuration, SBY system is not implemented, return zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

cardStatusMode 1.3.6.1.4.1.119.2.3.14.9.7.1.1.4
Operational mode of the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER act(1), sby(2), single(3), other(4)  

cardStatusPriority 1.3.6.1.4.1.119.2.3.14.9.7.1.1.5
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER local(1), remotePrimary(2), remoteSecoundary(3)  

cardStatusAtmAddr 1.3.6.1.4.1.119.2.3.14.9.7.1.1.6
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0|20)  

cardStatusMateAtmAddr 1.3.6.1.4.1.119.2.3.14.9.7.1.1.7
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0|20)  

cardOpeTable 1.3.6.1.4.1.119.2.3.14.9.7.2
The table showing the command operations to the line card with CPU. If the card configured on SBY system is indicated, return noSuchName.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CardOpeEntry

cardOpeEntry 1.3.6.1.4.1.119.2.3.14.9.7.2.1
Entry of command operation to the line card with CPU.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CardOpeEntry  

cardOpeReset 1.3.6.1.4.1.119.2.3.14.9.7.2.1.1
Card Reset processing. Return noOperation(1) at read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(1), reset(2), ach(3)  

cardOpeDiagnosis 1.3.6.1.4.1.119.2.3.14.9.7.2.1.2
Card diagnostic processing. Diagnose the SBY system card of double configuration with (the ACT system card). Return noOperation (1) at read.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER noOperation(1), diagnosis(2)  

cardOpeSave 1.3.6.1.4.1.119.2.3.14.9.7.2.1.3
Card Save processing. Save the system configuration information in FROM. If it is of double configuration, save it in SBY system FROM as well. Return noOperation (1) at read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(1), save(2)  

cardOpeSaveResult 1.3.6.1.4.1.119.2.3.14.9.7.2.1.4
The result of card save processing. OK /NG indicate that SAVE processing completed/failed, respectively. (NearEND) indicates that the number of writes into FROM approaches to the limit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER succeed(1), succeed-act(2), succeed-sby(3), temporaryFailure(4), nearend(5), nearend-act(6), nearend-act-failure-sby(7), nearend-sby(8), nearend-sby-failure-act(9), notReady(10), ready(11)  

cardOpeCopy 1.3.6.1.4.1.119.2.3.14.9.7.2.1.5
Card Copy processing. Return noOperation (1) at read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(1), copy-all-from-act(2), copy-all-from-sby(3), copy-config-from-act(4), copy-config-from-sby(5), copy-system-from-act(6), copy-system-from-sby(7)  

cardOpeCopyResult 1.3.6.1.4.1.119.2.3.14.9.7.2.1.6
Result of Card Copy processing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER succeed(1), temporaryFailure(2), nearend(3), notReady(4), ready(5)  

clockOpe 1.3.6.1.4.1.119.2.3.14.9.8.1
OBJECT IDENTIFIER    

clockOpeStatus 1.3.6.1.4.1.119.2.3.14.9.8.1.1
Used to control Clock setting processing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER allocate(1), set(2), free(3)  

clockOpeCause 1.3.6.1.4.1.119.2.3.14.9.8.1.2
Result of Clock setting processing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noWriting(1), other(2), succeed(3), setWarning(4), parameterNotEnough(5), portNotExist(6), portOutOfRange(7), allPortFailure(8)  

clockOpeMode 1.3.6.1.4.1.119.2.3.14.9.8.1.3
Clock Mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER master(1), slave(2)  

clockOpeAccuracy 1.3.6.1.4.1.119.2.3.14.9.8.1.4
Accuracy[ppm] of clock. If no set, value is -1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255 | -1  

clockOpeSlaveLine1 1.3.6.1.4.1.119.2.3.14.9.8.1.5
Slave line number 1. If no set, value is -1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..32 | -1  

clockOpeSlaveLine2 1.3.6.1.4.1.119.2.3.14.9.8.1.6
Slave line number 2. Slave line number 1 shall be set already. If no set, value is -1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..32 | -1  

clockOpeSlaveLine3 1.3.6.1.4.1.119.2.3.14.9.8.1.7
Slave line number 3. Slave line number 1~2 shall be set already. If no set, value is -1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..32 | -1  

clockOpeSlaveLine4 1.3.6.1.4.1.119.2.3.14.9.8.1.8
Slave line number 4. Slave line number 1~3 shall be set already. If no set, value is -1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..32 | -1  

clockMode 1.3.6.1.4.1.119.2.3.14.9.8.2
Clock Mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER master(1), slave(2)  

clockAccuracy 1.3.6.1.4.1.119.2.3.14.9.8.3
Accuracy[ppm] of clock.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255 | -1  

clockSlaveLine 1.3.6.1.4.1.119.2.3.14.9.8.4
The number of the actually slaved line. If mode is master (1), it is -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

clockSlaveLine1 1.3.6.1.4.1.119.2.3.14.9.8.5
Slave line number 1. If no set, value is -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

clockSlaveLine1Status 1.3.6.1.4.1.119.2.3.14.9.8.6
State of slave line 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ClockSlaveLineStatus  

clockSlaveLine2 1.3.6.1.4.1.119.2.3.14.9.8.7
Slave line number 2. If no set, value is -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

clockSlaveLine2Status 1.3.6.1.4.1.119.2.3.14.9.8.8
State of slave line 2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ClockSlaveLineStatus  

clockSlaveLine3 1.3.6.1.4.1.119.2.3.14.9.8.9
Slave line number 3. If no set, value is -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

clockSlaveLine3Status 1.3.6.1.4.1.119.2.3.14.9.8.10
State of slave line 3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ClockSlaveLineStatus  

clockSlaveLine4 1.3.6.1.4.1.119.2.3.14.9.8.11
Slave line number 4. If no set, value is -1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

clockSlaveLine4Status 1.3.6.1.4.1.119.2.3.14.9.8.12
State of slave line 4.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ClockSlaveLineStatus  

diagActionStatus 1.3.6.1.4.1.119.2.3.14.9.9.1
Used to control diagnostics test processing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER allocate(1), start(2), execute(3), end(4), free(5)  

diagActionKind 1.3.6.1.4.1.119.2.3.14.9.9.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER switch(1), cpu(2), slot(3)  

diagPreCause 1.3.6.1.4.1.119.2.3.14.9.9.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), succeed(2), parameterNotEnough(3), notInstalled(4), notSupport(5), diagnostics(6), clkChgError(7), initializing(8), sbyAccessError(9)  

diagCause 1.3.6.1.4.1.119.2.3.14.9.9.4
Result of diagnostics test processing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), diagNG-SC(1020004), diagNG-BF(1030004), diagNG-ES0(1040007), diagNG-ES1(1040107), diagNG-SAR(1050005), diagNG-DI(1060010), diagNG-CPU(1070002), diagNG-CPU-Register(1600201), diagNG-CPU-Timer-Test(1600202), diagNG-CPU-MM-Test(1600203), diagNG-CPU-DRAM-Partial-Write(1600204), diagNG-CPU-Memory-Machining(1600205), diagNG-CPU-Cash-Test(1600206), diagNG-CPU-BSN-Parity(1600207), diagNG-CPU-LANCE-LoopBack(1600208), diagNG-Local-Memory(1600301), diagNG-DMAC-Register(1600302), diagNG-MISCEMA-Register(1600303), diagNG-XACK-Interrupt(1600304), diagNG-ASW-Register(1600401), diagNG-BMT(1600402), diagNG-Failer-Detect(1600403), diagNG-SAR-Register(1600501), diagNG-SAR-Control-Memory(1600502), diagNG-SAR-Packet-Memory(1600503), diagNG-DI-Register(1600504), diagNG-DI-Memory(1600505), diagNG-ES-LoopBack(1600601), diagNG-ES-Own-LoopBack(1600602), diagNG-ES-Other-LoopBack(1600603), diagNG-ES-Own-Broadcast-LoopBack(1600604), diagNG-ES-Other-Broadcast-LoopBack(1600605), diagNG-ES-Nto1-Test(1600606), diagNG-ATOM-Buffer-OVF(1600607), diagNG-BackPressure(1600608), diagNG-RICEtoCell-Compete(1600609), diagNG-SAR-LoopBack(1600701), diagNG-DI-LoopBack(1600702), diagNG-SW-Own-LoopBack(1600703), diagNG-SW-Other-LoopBack(1600704), diagNG-Illegal-Cell-Detect(1600705), diagNG-SARtoPacket-Compete(1600706), diagNG-PCMCIA-Register(1601101), diagNG-IXB-Register(2010002), diagNG-OXB-Register(2020003), diagNG-UHT-Register(2030003), diagNG-IBC-Register(2040008), diagNG-IBC-RIRO-SGRAM(2040009), diagNG-IBC-HT-i-SGRAM(2040010), diagNG-IBC-RIRO-SRAM(2040011), diagNG-OBC-Register(2040012), diagNG-OBC-CellBuffer(2040013), diagNG-OBC-HT-o(2040014), diagNG-OBC-BCI-BMT(2040015), diagNG-FR-SDRAM(2090006), diagNG-PHY0(3010002), diagNG-PHY1(3010102), diagNG-PHY2(3010202), diagNG-PHY3(3010302), diagNG-MUX(3020012), diagNG-CU2INF(3030002), diagNG-UNIC(3040003), diagNG-CFAD(3050003), diagNG-PLD(3060003), diagNG-FPGA(3070004), diagNG-FRM0(3080004), diagNG-FRM1(3080104), diagNG-S-UNI622(3120004), diagNG-TAC0(3130001), diagNG-TAC1(3130101), diagNG-TAC2(3130201), diagNG-TAC3(3130301), diagNG-LCA-Common(3150001), diagNG-LCA-Separate(3150002), diagNG-UCFAD2(3160001), diagNG-PM7345-0(3140005), diagNG-PM7345-1(3140105), diagNG-PM7345-2(3140205), diagNG-PM7345-3(3140305), diagNG-PM4341A-0(3170001), diagNG-PM4341A-1(3170101), diagNG-PM4341A-2(3170201), diagNG-PM4341A-3(3170301), diagNG-PM6341-0(3180001), diagNG-PM6341-1(3180101), diagNG-PM6341-2(3180201), diagNG-PM6341-3(3180301), diagNG-DCS-LCA(3230003), diagNG-ALARM(3190001), diagNG-FRAME(3190002), diagNG-TS-CTL(3190003), diagNG-FIFO-CTL(3190004), diagNG-AAL1-SAR(3200001), diagNG-FPGA-CE-DS1(3210003), diagNG-FPGA-CE-E1(3220004), diagNG-WAC-021(3240001), diagNG-CPU-DRAM(3250001), diagNG-CPU-Tout(3250002)  

diagParam1 1.3.6.1.4.1.119.2.3.14.9.9.5
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

pnniNode 1.3.6.1.4.1.119.2.3.14.9.10.1
OBJECT IDENTIFIER    

pnniNodeOpe 1.3.6.1.4.1.119.2.3.14.9.10.1.1
OBJECT IDENTIFIER    

pnniNodeTable 1.3.6.1.4.1.119.2.3.14.9.10.1.2
Table of PNNI Logical node attributes. A row exist every PNNI peer group which the managed system belongs to.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PnniNodeEntry

pnniNodeEntry 1.3.6.1.4.1.119.2.3.14.9.10.1.2.1
Entry of pnniNodeTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PnniNodeEntry  

pnniNodeLevel 1.3.6.1.4.1.119.2.3.14.9.10.1.2.1.1
PNNI hierarchy level where node(s) reside.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PnniLevel  

pnniNodeId 1.3.6.1.4.1.119.2.3.14.9.10.1.2.1.2
Node ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PnniNodeId  

pnniNodeAtmAddress 1.3.6.1.4.1.119.2.3.14.9.10.1.2.1.3
ATM End System Address of node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PnniAtmAddr  

pnniNodePeerGroupId 1.3.6.1.4.1.119.2.3.14.9.10.1.2.1.4
Peer Group Identifier of the peer group which a node belongs to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PnniPeerGroupId  

pnniNodeRestrictedTransit 1.3.6.1.4.1.119.2.3.14.9.10.1.2.1.5
Restrict a node to be used as a transit route.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TruthValue  

pnniNodeRestrictedBranching 1.3.6.1.4.1.119.2.3.14.9.10.1.2.1.6
Restrict a node to be used as a branch point of point-to-multipoint.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TruthValue  

pnniNodeLeadershipPriority 1.3.6.1.4.1.119.2.3.14.9.10.1.2.1.7
Leadership priority which a node notifies of.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

matCmdStatus 1.3.6.1.4.1.119.2.3.14.9.11.1
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER allocate(1), inActive(2), active(3), free(4)  

matCmdInput 1.3.6.1.4.1.119.2.3.14.9.11.2
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

matCmdOutput 1.3.6.1.4.1.119.2.3.14.9.11.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

matCmdOutputType 1.3.6.1.4.1.119.2.3.14.9.11.4
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), continued(2), interactive(3)  

matCmdStop 1.3.6.1.4.1.119.2.3.14.9.11.5
When the value is set to 'stop', the MAT command is stopped. When the value is set to 'noOperation', no operation is performed. When read, the value 'noOperation' is returned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noOperation(1), stop(2)  

matCmdTimeOut 1.3.6.1.4.1.119.2.3.14.9.11.6
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..180