NEWBRIDGE-MIB

File: NEWBRIDGE-MIB.mib (112616 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
NNCGNI00X1-SMI

Imported symbols

enterprises Counter OBJECT-TYPE
DisplayString PhysAddress nncInterimMib

Defined Types

AlarmCode  
INTEGER 1..255    

AlarmQueue  
INTEGER major(1), minor(2), diag(3)    

AlarmQueueIndex  
INTEGER 1..64    

ExtendedCounter  
OCTET STRING Size(8..8)    

ExtendedTime  
OCTET STRING Size(8..8)    

PositionNumber  
INTEGER    

CircuitNumber  
INTEGER 1..32    

DescendantNumber  
INTEGER 1..1023    

DeviceNumber  
OCTET STRING    

ModuleType  
INTEGER    

ModuleID  
INTEGER    

SubModuleType  
INTEGER    

SubModuleID  
INTEGER    

FilterEntry  
OCTET STRING Size(8..8)    

BridgeIdentifier  
OCTET STRING Size(8..8)    

InterfaceIndex  
INTEGER    

OneByte  
INTEGER 0..255    

T1E1Loopback  
INTEGER none(1), equipment(2), equipment-all-ones(3), equipment-digital(4), line(5), line-and-equipment(6)    

T1E1Status  
INTEGER 0..65535    

ControlLeads  
INTEGER 0..255    

NnciSystemTableEntry  
SEQUENCE    
  nnciSystemDate DisplayString
  nnciSystemProductName DisplayString
  nnciSystemGeneric DisplayString
  nnciSystemNVMAllocation OCTET STRING
  nnciSystemNVMRepairInfo OCTET STRING
  nnciSystemTime DisplayString

NnciSerialPortTableEntry  
SEQUENCE    
  nnciSpBaudRate INTEGER
  nnciSpWordLength INTEGER
  nnciSpStopBits INTEGER
  nnciSpParity INTEGER

NnciAlarmTableEntry  
SEQUENCE    
  nnciAlarmCount INTEGER
  nnciAlarmQueueEntry OCTET STRING
  nnciAlarmQueueEntryStatus INTEGER
  nnciAlarmSeqNum INTEGER
  nnciAlarmCodePriority INTEGER
  nnciAlarmsDeleteQueueEntry INTEGER
  nnciAlarmQueueType INTEGER

NnciDiagTableEntry  
SEQUENCE    
  nnciDiagEnableBackground INTEGER
  nnciDiagResults INTEGER

NnciNetSynchTableEntry  
SEQUENCE    
  nnciNetSynchSourceStatus INTEGER
  nnciNetSynchTimingSource INTEGER
  nnciNetSynchReacquisitionMode INTEGER
  nnciNetSynchCurrentSource INTEGER
  nnciNetSynchRecoveryInterval INTEGER
  nnciNetSynchQuality INTEGER
  nnciNetSynchSourceClass INTEGER
  nnciNetSynchNodeClass INTEGER

NnciSlotTableEntry  
SEQUENCE    
  nnciSlotName DisplayString
  nnciSlotProgType ModuleType
  nnciSlotPresType ModuleType
  nnciSlotStatus INTEGER
  nnciSlotModuleID ModuleID
  nnciSlotSubModuleProgType SubModuleType
  nnciSlotSubModulePresType SubModuleType
  nnciSlotFirmwareID INTEGER
  nnciSlotBusyOut INTEGER
  nnciSlotSubModuleID SubModuleID
  nnciSlotVariantID INTEGER
  nnciSlotResetCard INTEGER
  nnciSlotHardwareRevision INTEGER

NnciT1SlotTableEntry  
SEQUENCE    
  nnciT1SlotAlarmControl INTEGER
  nnciT1SlotFramingStyle INTEGER
  nnciT1SlotZeroSuppression INTEGER
  nnciT1SlotLinkStatus T1E1Status
  nnciT1SlotLoopLength INTEGER
  nnciT1SlotThreshold INTEGER
  nnciT1SlotLoopback T1E1Loopback
  nnciT1SlotTrunkConditioningEnable INTEGER
  nnciT1SlotAlarmDeclarationTime INTEGER
  nnciT1SlotAlarmClearingTime INTEGER
  nnciT1SlotCRCFraming INTEGER

NnciE1SlotTableEntry  
SEQUENCE    
  nnciE1SlotAlarmControl INTEGER
  nnciE1SlotLoopback T1E1Loopback
  nnciE1SlotSignalling INTEGER
  nnciE1SlotShieldLevel INTEGER
  nnciE1SlotLinkStatus T1E1Status
  nnciE1SlotThreshold INTEGER
  nnciE1TypeOfStats INTEGER
  nnciE1SlotTrunkConditioningEnable INTEGER
  nnciE1SlotAlarmDeclarationTime INTEGER
  nnciE1SlotAlarmClearingTime INTEGER
  nnciE1SlotCRCFraming INTEGER

NnciDevTableEntry  
SEQUENCE    
  nnciDevName DisplayString
  nnciDevLoopback INTEGER
  nnciDevMateDevice DeviceNumber
  nnciDevSetShowSig INTEGER
  nnciDevReady INTEGER
  nnciDevActive INTEGER
  nnciDevConnected INTEGER
  nnciDevOutOfService INTEGER
  nnciDevUnderMaintenance INTEGER
  nnciDevBusyOut INTEGER
  nnciDevFailed INTEGER
  nnciDevDiagEnable INTEGER

NnciT1TableEntry  
SEQUENCE    
  nnciT1BusyOut INTEGER
  nnciT1RobbedBitSig INTEGER
  nnciT1Inversion INTEGER
  nnciT1DefaultData OneByte
  nnciT1FirstCode INTEGER
  nnciT1SecondCode INTEGER
  nnciT1PartOfSuperRate CircuitNumber
  nnciT1BitsUsed INTEGER
  nnciT1SuperRateCircuitMap INTEGER
  nnciT1SuperRateNumCircuits INTEGER

NnciE1TableEntry  
SEQUENCE    
  nnciE1BusyOut INTEGER
  nnciE1AlternateDigitInversion INTEGER
  nnciE1DefaultData OneByte
  nnciE1FirstCode INTEGER
  nnciE1SecondCode INTEGER
  nnciE1PartOfSuperRate CircuitNumber
  nnciE1BitsUsed INTEGER
  nnciE1SuperRateCircuitMap INTEGER
  nnciE1SuperRateNumCircuits INTEGER

NnciSdcTableEntry  
SEQUENCE    
  nnciSdcInterfaceControl INTEGER
  nnciSdcInterfaceSpeed INTEGER
  nnciSdcLeadsDefaultOn ControlLeads
  nnciSdcLeadDefaultOff ControlLeads
  nnciSdcInterfaceStatus ControlLeads

NnciHdlcTableEntry  
SEQUENCE    
  nnciHdlcBytesTransmitted ExtendedCounter
  nnciHdlcFramesTransmitted ExtendedCounter
  nnciHdlcRxGoodBytes ExtendedCounter
  nnciHdlcRxGoodFrames ExtendedCounter
  nnciHdlcUnderrun ExtendedCounter
  nnciHdlcCRCError ExtendedCounter
  nnciHdlcAlignmentError ExtendedCounter
  nnciHdlcOverrun ExtendedCounter
  nnciHdlcAbort ExtendedCounter
  nnciHdlcSinceLastReset ExtendedTime
  nnciHdlcApplication INTEGER

NnciBridgeTableEntry  
SEQUENCE    
  nnciBrdgAddress PhysAddress
  nnciBrdgUptime ExtendedTime
  nnciBrdgInterfaceCount INTEGER
  nnciBrdgMaxInterfaceCount INTEGER
  nnciBrdgMapCircuitToInterface InterfaceIndex

NnciFilterTableEntry  
SEQUENCE    
  nnciFilterReset INTEGER
  nnciFilterLearn INTEGER
  nnciFilterPermDBChange INTEGER
  nnciFilterPermDBEntryCount INTEGER
  nnciFilterPermDBContents FilterEntry
  nnciFilterAddPermDBEntry FilterEntry
  nnciFilterDeletePermDBEntry FilterEntry
  nnciFilterAFMaxEntries INTEGER
  nnciFilterAFEntryLifetime INTEGER
  nnciFilterAFEntryCount INTEGER
  nnciFilterAFContents FilterEntry
  nnciFilterForwardMatrix INTEGER
  nnciFilterFloodUnicastMatrix INTEGER
  nnciFilterTakeSnapShot INTEGER
  nnciFilterFloodMulticastMatrix INTEGER
  nnciFilterFloodBroadcastMatrix INTEGER
  nnciFilterPermNVDBContents FilterEntry
  nnciFilterDeleteAllPermEntries INTEGER

NnciStpTableEntry  
SEQUENCE    
  nnciStpEnable INTEGER
  nnciStpBridgePriority INTEGER
  nnciStpRoot BridgeIdentifier
  nnciStpRootPathCost INTEGER
  nnciStpRootInterface InterfaceIndex
  nnciStpMaxAge INTEGER
  nnciStpHelloTime INTEGER
  nnciStpForwardDelay INTEGER
  nnciStpMyMaxAge INTEGER
  nnciStpMyHelloTime INTEGER
  nnciStpMyForwardDelay INTEGER
  nnciStpTopologyChangeDetected INTEGER
  nnciStpSendingTopologyChange INTEGER
  nnciStpTimeSinceLastTopologyChange ExtendedTime
  nnciStpTopologyChanges Counter
  nnciStpTopologyChangeAck INTEGER
  nnciStpInterfacePriority INTEGER
  nnciStpInterfaceCost INTEGER
  nnciStpDesignatedBridge BridgeIdentifier
  nnciStpDesignatedInterface InterfaceIndex
  nnciStpDesignatedRoot BridgeIdentifier
  nnciStpDesignatedCost INTEGER
  nnciStpConfigurationMessagePending INTEGER
  nnciStpAllowableDeviations INTEGER
  nnciStpCostMultiplier INTEGER
  nnciStpUserAssignedCost INTEGER

Defined Values

nnciSystem 1.3.6.1.4.1.123.2.1
OBJECT IDENTIFIER    

nnciSp 1.3.6.1.4.1.123.2.2
OBJECT IDENTIFIER    

nnciAlarm 1.3.6.1.4.1.123.2.4
OBJECT IDENTIFIER    

nnciDiag 1.3.6.1.4.1.123.2.3
OBJECT IDENTIFIER    

nnciNetSynch 1.3.6.1.4.1.123.2.7
OBJECT IDENTIFIER    

nnciSlot 1.3.6.1.4.1.123.2.10
OBJECT IDENTIFIER    

nnciT1Slot 1.3.6.1.4.1.123.2.22
OBJECT IDENTIFIER    

nnciE1Slot 1.3.6.1.4.1.123.2.20
OBJECT IDENTIFIER    

nnciDev 1.3.6.1.4.1.123.2.11
OBJECT IDENTIFIER    

nnciT1 1.3.6.1.4.1.123.2.23
OBJECT IDENTIFIER    

nnciE1 1.3.6.1.4.1.123.2.21
OBJECT IDENTIFIER    

nnciSdc 1.3.6.1.4.1.123.2.72
OBJECT IDENTIFIER    

nnciHdlc 1.3.6.1.4.1.123.2.66
OBJECT IDENTIFIER    

nnciBridge 1.3.6.1.4.1.123.2.55
OBJECT IDENTIFIER    

nnciBrdgSt 1.3.6.1.4.1.123.2.61
OBJECT IDENTIFIER    

nnciFilter 1.3.6.1.4.1.123.2.62
OBJECT IDENTIFIER    

nnciStp 1.3.6.1.4.1.123.2.63
OBJECT IDENTIFIER    

nnciSystemTable 1.3.6.1.4.1.123.2.1.1
This table contains interesting general information about the managed element in its entirety
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciSystemTableEntry

nnciSystemTableEntry 1.3.6.1.4.1.123.2.1.1.1
A list of general information about the managed element
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciSystemTableEntry  

nnciSystemDate 1.3.6.1.4.1.123.2.1.1.1.2
The current date as known by the node.The date is formatted as a sequence of nine ASCII characters in the form DD-MMM-YY, where DD is the day of the month (01..31), MMM is the month of the year, e.g. JAN, and YY is the last two digits of the year, e.g. 90.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

nnciSystemProductName 1.3.6.1.4.1.123.2.1.1.1.4
The marketing name for the product, e.g. 8230 MainStreet for something if sysObjectId.0 = nnci8230
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

nnciSystemGeneric 1.3.6.1.4.1.123.2.1.1.1.5
This object identifies the revision of the firmware in the standard Newbridge fashion. The identifier is a string of 10 ASCII characters of the form M11D-HL-PP where: D indicates the release number of the software LL indicates the load of the software, and PP indicates the patch-level of the firmware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

nnciSystemNVMAllocation 1.3.6.1.4.1.123.2.1.1.1.30
This object provides status information about the non-volatile memory present on the main card of the system. The information returned includes the size of a single block of NVM, the total number of blocks available for use, the number of bad blocks and the number of blocks in use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

nnciSystemNVMRepairInfo 1.3.6.1.4.1.123.2.1.1.1.31
This object returns the details of the latest repair performed on the non-volatile memory present on the main card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

nnciSystemTime 1.3.6.1.4.1.123.2.1.1.1.38
The current time of day including seconds. The time is represented as a sequence of 9 ASCII characters in the form HH:MM:SS, where HH is the hour of the day (0..12), MM is the minute of the hour and SS are the seconds of the minute (0..59)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

nnciSerialPortTable 1.3.6.1.4.1.123.2.2.1
This table contains the configuration information for an asynchronous management port for a standalone node.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciSerialPortTableEntry

nnciSerialPortTableEntry 1.3.6.1.4.1.123.2.2.1.1
A list of configuration information for a management port on a standalone node
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciSerialPortTableEntry  

nnciSpBaudRate 1.3.6.1.4.1.123.2.2.1.1.1
The baud rate of the asynchronous management port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), b300(2), b600(3), b1200(4), b2400(5), b4800(6), b9600(7), b38400(8)  

nnciSpWordLength 1.3.6.1.4.1.123.2.2.1.1.2
The word length used on the asynchronous management port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER seven(3), eight(4)  

nnciSpStopBits 1.3.6.1.4.1.123.2.2.1.1.3
The number of stop bits used by the asynchronous management port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciSpParity 1.3.6.1.4.1.123.2.2.1.1.4
The parity used on the asynchronous management port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER odd(1), even(2), none(3)  

nnciAlarmTable 1.3.6.1.4.1.123.2.4.1
This table contains all the configuration and status information about the alarm mechanism along with the alarms themselves.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciAlarmTableEntry

nnciAlarmTableEntry 1.3.6.1.4.1.123.2.4.1.1
A list of all of the configuration and status information for a node, along with the alarm queues themselves.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciAlarmTableEntry  

nnciAlarmCount 1.3.6.1.4.1.123.2.4.1.1.1
The number of alarms in the specified queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciAlarmQueueEntry 1.3.6.1.4.1.123.2.4.1.1.2
When read, this object returns the particulars of the entry in the specified queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

nnciAlarmQueueEntryStatus 1.3.6.1.4.1.123.2.4.1.1.3
The status of an alarm.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER nonTep1e(0), unackNotRemedied(1), unackRedmedyUnack(2), ackNotRemedied(3), ackRemedyUnack(4), ackRemedyAck(5), clearingAlarmUnack(6), clearingAlarmAck(7)  

nnciAlarmSeqNum 1.3.6.1.4.1.123.2.4.1.1.4
The next sequence number that will be used by the node. The sequence numbers are a unique, within a single node, identifier for an alarm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciAlarmCodePriority 1.3.6.1.4.1.123.2.4.1.1.6
This value of this object controls into which queue an alarm is placed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER major(1), minor(2), diagnostic(3)  

nnciAlarmDeleteQueueEntry 1.3.6.1.4.1.123.2.4.1.1.8
A set to this object is deletes the first N alarms from the specified alarm queue.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER  

nnciAlarmQueueType 1.3.6.1.4.1.123.2.4.1.1.9
This paramater is used to control the behaviour of the alarm queue in the overlfow case, i.e. when the alarm facility attempts to place the 65th alarm into the queue. If the queue type is set to Fixed, the 65th and 64th alarms will be discarded and the 'Too Many Alarms' alarm added as the last entry in the queue. If the queue type is set to Circular, the 65th alarm will overwrite the first alarm in the queue
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fixedAlarmQueue(1), circularAlarmQueue(2)  

nnciDiagTable 1.3.6.1.4.1.123.2.3.1
This table contains all of the configuration and status information related to diagnostics on a node.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciDiagTableEntry

nnciDiagTableEntry 1.3.6.1.4.1.123.2.3.1.1
A list of all of the configuration and status information related to node diagnostics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciDiagTableEntry  

nnciDiagEnable 1.3.6.1.4.1.123.2.3.1.1.1
This object controls whether or not background diagnostics are run. If the object is set to 2 (enabled), then background diagnostics are run periodically. If the object is set to 1 (disabled), background diagnostics are not performed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

nnciDiagResults 1.3.6.1.4.1.123.2.3.1.1.5
This object indicates the results of power on and background diagnostics. Any bit that is asserted corresponds to a failure of a component of the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciNetSynchTable 1.3.6.1.4.1.123.2.7.1
This table contains all of the configuration and status information for the network synchronization mechanism for a standalone node.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciNetSynchTableEntry

nnciNetSynchTableEntry 1.3.6.1.4.1.123.2.7.1.1
A list of all of the configuration and status information related to network synchronization.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciNetSynchTableEntry  

nnciNetSynchSourceStatus 1.3.6.1.4.1.123.2.7.1.1.1
This object returns the current status of the specified source of synchronization. A set to this object changes the enabled/disabled status of the source. If the source is disabled, writing anything other than 'Disabled' will cause the source to be enabled, and its state will change to one of Not Ready, Ready, or Current. If the source is enabled, writing 'Disabled' to this object will disable the source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), ready(2), current(3), timedRecovery(4), failed(5), shutDown(6), notReady(7), autoRecovery(8), cannotLock(9), enabled(10), illegalState(11), undefinedSource(12), unavailable(13), acquiring(14)  

nnciNetSynchTimingSource 1.3.6.1.4.1.123.2.7.1.1.2
The device which provides timing when the specified source of synchronization is selected. The sync source must be disabled before changing this object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER exp1(3), exp2(4), freerun(18)  

nnciNetSynchReacquisitionMode 1.3.6.1.4.1.123.2.7.1.1.3
How the source of synchronization will be treated in the event a failure is detected. If Manual is selected, the source will remain unused until it is re-selected. If Automatic recovery is selected, the source will be returned to use as soon as it is valid, e.g. when a T1 link regains frame alignment. If Timed recovery is selected, the node will attempt to use the source at the specified interval.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER manual(1), automatic(2), timed(3)  

nnciNetSynchCurrentSource 1.3.6.1.4.1.123.2.7.1.1.4
The current source of synchronization for the node. A set to this object toggles the ready/current status of the source. If the source is ready, it will become the current source. If the source is current, it will become ready, and the next-best source will become the current source. If the source is neither ready nor current, a set to this object has no effect.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciNetSynchRecoveryInterval 1.3.6.1.4.1.123.2.7.1.1.6
This object is used to set the interval between recovery attempts for a source of synchronization that is using Timed recovery in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciNetSynchQuality 1.3.6.1.4.1.123.2.7.1.1.9
This object is used to set the maximum permissible number of failures that can be experienced by a source in an hour. If this limit is exceeded, an alarm is raised and the source is placed into the disabled state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciNetSynchSourceClass 1.3.6.1.4.1.123.2.7.1.1.11
This object is used to set the class of a source. The source with the best class will provide system sync when several sources are Ready. Note that the freerun source (source 5) does not actually make use of this object. It gets its class from nnciNetSynchNodeClass.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciNetSynchNodeClass 1.3.6.1.4.1.123.2.7.1.1.12
This object is used to set the class of the node. The node will freerun if the value of this object is lower than the nnciNetSynchSourceClass of the other sources.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciSlotTable 1.3.6.1.4.1.123.2.10.1
This table contains all of the common, slot configuration and status information for a standalone node
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciSlotTableEntry

nnciSlotTableEntry 1.3.6.1.4.1.123.2.10.1.1
A list of all of the common, per-slot configuration and status information for a standalone node.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciSlotTableEntry  

nnciSlotName 1.3.6.1.4.1.123.2.10.1.1.1
An arbitrary name for a slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

nnciSlotProgType 1.3.6.1.4.1.123.2.10.1.1.2
This object is used to specify what kind of module should be present in the specified position . If the value in this object does not match the value in the nnciSlotPresType object, then the position will be held out of service.
Status: mandatory Access: read-write
OBJECT-TYPE    
  ModuleType  

nnciSlotPresType 1.3.6.1.4.1.123.2.10.1.1.3
This object is used to specify what kind of module is present in the specified position . If the value of this object does not match the value of the nnciSlotProgType object, the position will be held out of service.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ModuleType  

nnciSlotStatus 1.3.6.1.4.1.123.2.10.1.1.4
This object contains the current status of the specified position . The status reflects whether a module is present, and if so, is it of the expected type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER empty(1), ok(2), fault-on-module(3), module-dead(4), unknown-module-type(5), module-type-mismatch(6), sub-module-type-mismatch(7), wrong-firmware(9), wrong-variant(12)  

nnciSlotModuleID 1.3.6.1.4.1.123.2.10.1.1.5
The hardware identification number assigned to the module that is present in the specified position. If there is no module installed in the position, the value returned will be 0 (zero). Note that this identification number identifies what kind of module is present; the revision level of the module is available in the nnciSlotHardwareRevision object
Status: mandatory Access: read-only
OBJECT-TYPE    
  ModuleID  

nnciSlotSubModuleProgType 1.3.6.1.4.1.123.2.10.1.1.6
What kind of 'sub-module' should be present in the specified slot. If the value in this object does not match the value in the nnciSlotModulePresType object, then the position will be held out of service. Any attempt to set this object for other than the expansion module positions will be rejected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  SubModuleType  

nnciSlotSubModulePresType 1.3.6.1.4.1.123.2.10.1.1.7
What kind of 'sub-module' is present in the specified position. If the value of this object does not match the value of the nnciSlotModuleProgType object, the position will be held out of service.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SubModuleType  

nnciSlotFirmwareID 1.3.6.1.4.1.123.2.10.1.1.8
The revision level of the firmware, if any, that is present on a module. If no firmware is present, the value will be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciSlotBusyOut 1.3.6.1.4.1.123.2.10.1.1.9
This object is used to take circuits on a specified slot out of service. If the value of this object is hold-out-of-service, then the circuits on the slot will not be used even if all alarms are cleared and the circuits would normally be placed into service. If the value of this object is normal, then the circuits will operate as if this object did not exist. If the circuits are the specified position are in service when the object is set, it will be immediately removed from service.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), hold-out-of-service(2)  

nnciSlotSubModuleID 1.3.6.1.4.1.123.2.10.1.1.10
The hardware identification number assigned to the sub-module that is present in the specified position. If there is no sub-module installed in the position, or no sub-module present, the value returned will be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SubModuleID  

nnciSlotVariantID 1.3.6.1.4.1.123.2.10.1.1.14
The variant identification number for the module which is installed in the specified slot. If there is no module installed, the value returned will be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciSlotResetCard 1.3.6.1.4.1.123.2.10.1.1.15
This object is used to cause the node to re-initialize the specified module. Any set to this object will cause the specified module to be re-initialized. If a set is attempted with the modifier set to select the main card, the whole node will be reset. A get on this object will always return zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciSlotHardwareRevision 1.3.6.1.4.1.123.2.10.1.1.19
The engineering revision level of the module that occupies the specified position. The high nibble of the returned value is the major revision level and the low nibble is the minor revision, e.g. Engineering Revision 21 will be returned as $21.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciT1SlotTable 1.3.6.1.4.1.123.2.22.1
This table contains all of the configuration and status information for a T1 interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciT1SlotTableEntry

nnciT1SlotTableEntry 1.3.6.1.4.1.123.2.22.1.1
A list of all of the configuration and status information for a T1 interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciT1SlotTableEntry  

nnciT1SlotAlarmControl 1.3.6.1.4.1.123.2.22.1.1.1
This object can be used to control the alarm condition that is indicated by the specified interface. If ForceYellow is selected, the interface will provide the same indication to the far end as if the local interface had lost frame. If ForceAIS is selected, the interface will transmit an unframed all ones signal towards the far end.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAlarm(1), forceYellow(2), forceAIS(3)  

nnciT1SlotFramingStyle 1.3.6.1.4.1.123.2.22.1.1.2
This object is used to select either D4 or ESF framing for the T1 link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER d4Framing(1), esfFraming(2)  

nnciT1SlotZeroSuppression 1.3.6.1.4.1.123.2.22.1.1.3
This object is used to select the kind, if any, of zero-code suppression to be used on the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), b8zs(2), jamBit7(3)  

nnciT1SlotLinkStatus 1.3.6.1.4.1.123.2.22.1.1.7
This object returns the current 'alarm' state of the T1 facility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  T1E1Status  

nnciT1SlotLoopLength 1.3.6.1.4.1.123.2.22.1.1.8
This object is used to control the pre-equalization applied to signal before transmission.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER short(1), medium(2), long(3)  

nnciT1SlotThreshold 1.3.6.1.4.1.123.2.22.1.1.9
This object controls the system's tolerance of failures on the specified T1 link. If more than the specified number of failures occurs in one hour, the interface will be removed from consideration as a source of synchronization. A failure is defined as the occurrence of an alarm condition on the interface, i.e. one that results in any bits other than 0 (zero) or 9 (nine) being set in the nnciT1SlotLinkStatus object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciT1SlotLoopback 1.3.6.1.4.1.123.2.22.1.1.11
This object is used to set or remove loopbacks on the T1 link
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), equipment(2), equipment-all-ones(3), equipment-digital(4), line(5), line-and-equipment(6)  

nnciT1SlotTrunkConditioningEnable 1.3.6.1.4.1.123.2.22.1.1.16
This object controls when trunk-conditioning is applied to the specified T1 link. Trunk- conditioning is the process by which all of the connections to the link are temporarily broken and a known pattern is sent on each channel of the T1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciT1SlotAlarmDeclarationTime 1.3.6.1.4.1.123.2.22.1.1.17
This object controls the interval for which the local loss-of-frame condition is debounced. The debounce algorithm and default value correspond to the requirements of AT&T PUB 62411.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciT1SlotAlarmClearingTime 1.3.6.1.4.1.123.2.22.1.1.18
This object controls the interval for which the reacquisition of local frame is debounced. The debounce algorithm and default value correspond to the requirements of AT&T PUB 62411.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciT1SlotCRCFraming 1.3.6.1.4.1.123.2.22.1.1.20
This object controls whether a Cyclic Redundancy Check is used when the specified T1 link reframes. This is only applicable to T1 links that a programmed for ESF operation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

nnciE1SlotTable 1.3.6.1.4.1.123.2.20.1
This table contains all of the configuration and status information for a E1 interface
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciE1SlotTableEntry

nnciE1SlotTableEntry 1.3.6.1.4.1.123.2.20.1.1
A list of all of the configuration and status information for a E1 interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciE1SlotTableEntry  

nnciE1SlotAlarmControl 1.3.6.1.4.1.123.2.20.1.1.1
This object can be used to control the alarm condition that is indicated by the specified interface. If ForceAISInTS16 is selected, the interface will transmit a continuous all ones pattern in TS16 of the E1 link. If ForceAISAllTS is selected, the interface will transmit an un-framed 'all ones' signal on the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nonalarm(1), forceAISInTS16(2), forceAISInA11TS(3)  

nnciE1SlotLoopback 1.3.6.1.4.1.123.2.20.1.1.4
This object is used to set or remove loopbacks on the E1 interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), equipment(2), equipment-all-ones(3), equipment-digital(4), line(5), line-and-equipment(6)  

nnciE1SlotSignalling 1.3.6.1.4.1.123.2.20.1.1.7
This object is used to select either Common Channel Signalling (CCS) or Channel Associated Signalling (CAS) operation for the interface. CCS operation makes timeslot 16 of the E1 link available for user data . 31CHAN mode allows TS16 to be used for super-rate data, whereas CCS does not. In CAS operation, timeslot 16 is used to transfer ABCD bit signalling and thus is not available to carry user data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cas(1), ccs(2), thirtyOneChan(3)  

nnciE1SlotShieldLevel 1.3.6.1.4.1.123.2.20.1.1.9
This object is used to control the level of the coax shield at the E1 physical interface for each of the receive and transmit lines. The two shields (receive and transmit) can be controlled independently.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER both-grounded(1), onlyRX-grounded(2), onlyTX-grounded(3), neither-grounded(4)  

nnciE1SlotLinkStatus 1.3.6.1.4.1.123.2.20.1.1.11
This object returns the current 'alarm' state of the E1 interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  T1E1Status  

nnciE1SlotThreshold 1.3.6.1.4.1.123.2.20.1.1.12
This object controls the system's tolerance of failures on the specified interface. If more than the specified number of failures occurs in one hour, the interface will be removed from consideration as a source of synchronization. A failure is defined as the occurrence of an alarm condition on the interface, i.e. one that results in any bits other than 0 (zero) or 9 (nine) being set in the nnciE1SlotLinkStatus object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciE1TypeOfStats 1.3.6.1.4.1.123.2.20.1.1.14
The type of stats to be collected for this E1 link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER hdb3(1), crc4(2)  

nnciE1SlotTrunkConditioningEnable 1.3.6.1.4.1.123.2.20.1.1.21
This object controls when trunk-conditioning is applied to the specified interface. Trunk- conditioning is the process by which all of the connections to the interface are temporarily broken and a known pattern is sent on each channel of the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciE1SlotAlarmDeclarationTime 1.3.6.1.4.1.123.2.20.1.1.22
This object controls the interval for which the local loss-of-frame condition is debounced.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciE1SlotAlarmClearingTime 1.3.6.1.4.1.123.2.20.1.1.23
This object controls the interval for which the reacquisition of local frame is debounced.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciE1SlotCRCFraming 1.3.6.1.4.1.123.2.20.1.1.25
This object controls the generation and use of a Cyclic Redundancy Check during reframing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

nnciDevTable 1.3.6.1.4.1.123.2.11.1
This table contains all of the common, per-device configuration and status information for a circuit. Device-type specific information is found in other tables as appropriate.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciDevTableEntry

nnciDevTableEntry 1.3.6.1.4.1.123.2.11.1.1
A list of all of the common, per-device configuration and status information.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciDevTableEntry  

nnciDevName 1.3.6.1.4.1.123.2.11.1.1.2
A user-defined name for the specified circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

nnciDevLoopback 1.3.6.1.4.1.123.2.11.1.1.4
This object is used to apply and remove loopbacks on the specified circuit. Note that it may not be possible to apply loopbacks to some circuit types.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), lpbkA(2), lpbkB(3), lpbkC(4)  

nnciDevMateDevice 1.3.6.1.4.1.123.2.11.1.1.5
The device number of the device, if any, that is cross-connected to the device of interest. If there is no programmed connection, the device number will be zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DeviceNumber  

nnciDevSetShowSig 1.3.6.1.4.1.123.2.11.1.1.10
A get from this object will return the current value of signalling, as appropriate for the type of the specified device. When set, the bit pattern supplied will be used as the signalling that is being sent by the circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciDevReady 1.3.6.1.4.1.123.2.11.1.1.15
Whether or not the circuit is ready for use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notReady(0), ready(1)  

nnciDevActive 1.3.6.1.4.1.123.2.11.1.1.16
Whether or not the circuit is active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notActive(0), active(1)  

nnciDevConnected 1.3.6.1.4.1.123.2.11.1.1.17
Whether or not the circuit is connected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notConnected(0), connected(1)  

nnciDevOutOfService 1.3.6.1.4.1.123.2.11.1.1.18
Whether or not the circuit has detected an OutOfService condition.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inService(0), outOfService(1)  

nnciDevUnderMaintenance 1.3.6.1.4.1.123.2.11.1.1.21
True iff the circuit has been subject to a maintenance operation, e.g. a loopback.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noMaint(0), underMaint(1)  

nnciDevBusyOut 1.3.6.1.4.1.123.2.11.1.1.22
This object is used to remove a circuit from service.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notBusy(0), busiedOut(1)  

nnciDevFailed 1.3.6.1.4.1.123.2.11.1.1.23
True iff this circuit has failed a diagnostics test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notFailed(0), failed(1)  

nnciDevDiagEnable 1.3.6.1.4.1.123.2.11.1.1.24
Whether or not background diagnostics are enabled for this circuit (if applicable).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER diagDisabled(0), diagEnabled(1)  

nnciT1Table 1.3.6.1.4.1.123.2.23.1
This table contains all of the configuration and status information for a T1 circuit
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciT1TableEntry

nnciT1TableEntry 1.3.6.1.4.1.123.2.23.1.1
A list of all of the configuration and status information for an T1 circuit
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciT1TableEntry  

nnciT1BusyOut 1.3.6.1.4.1.123.2.23.1.1.1
What action will be taken on the circuit when the circuit is not connected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER idle(1), seized(2), oosA(3), oosB(4)  

nnciT1RobbedBitSig 1.3.6.1.4.1.123.2.23.1.1.4
This object is used to enable or disable Robbed-Bit Signalling for the circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER rbsOn(1), rbsOff(2)  

nnciT1Inversion 1.3.6.1.4.1.123.2.23.1.1.5
Whether or not data transmitted on this circuit is inverted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER invertOn(1), invertOff(2)  

nnciT1DefaultData 1.3.6.1.4.1.123.2.23.1.1.8
The value that is to be transmitted on the circuit when it is not connected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OneByte  

nnciT1FirstCode 1.3.6.1.4.1.123.2.23.1.1.9
The nnciT1FirstCode object is one of two which determines the signalling that will be sent during the Trunk-Conditioning process. This object determines the signalling that will be sent during a timed-break, if one is applied.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

nnciT1SecondCode 1.3.6.1.4.1.123.2.23.1.1.10
The nnciT1SecondCode object is the second of two objects which determines the signalling that will be sent during the Trunk-Conditioning process. This object determines the signalling that will be sent for the duration of the trunk-conditioning process, following the timed-break.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

nnciT1PartOfSuperRate 1.3.6.1.4.1.123.2.23.1.1.12
This parameter is used to form a circular linked list of circuit numbers which make up a superrate connection It contains the circuit number of the next circuit in the superrate connection or zero if the circuit is not part of a super-rate group
Status: mandatory Access: read-write
OBJECT-TYPE    
  CircuitNumber  

nnciT1BitsUsed 1.3.6.1.4.1.123.2.23.1.1.13
A bitmap which indicates which bits of the T1 circuit are to be used for data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

nnciT1SuperRateCircuitMap 1.3.6.1.4.1.123.2.23.1.1.20
When written to, this object builds the circularly-linked list of circuits represented by the one bits in the value written. When read, this object returns the bit map corresponding to the super-rate group of which this circuit is a member
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciT1SuperRateNumCircuits 1.3.6.1.4.1.123.2.23.1.1.21
When written to, this object builds the circularly-linked list of circuits to represent the super-rate group which begins at this circuit and contains the specified number of circuits. When read, this object returns the number of circuits in the super-rate group of which this circuit is a member
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciE1Table 1.3.6.1.4.1.123.2.21.1
This table contains all of the configuration and status information for a E1 circuit
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciE1TableEntry

nnciE1TableEntry 1.3.6.1.4.1.123.2.21.1.1
A list of all of the configuration and status information for an E1 circuit
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciE1TableEntry  

nnciE1BusyOut 1.3.6.1.4.1.123.2.21.1.1.3
What signalling will be transmitted on the circuit when the circuit is not connected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER idle(1), seized(2), oosA(3), oosB(4)  

nnciE1AlternateDigitInversion 1.3.6.1.4.1.123.2.21.1.1.6
Whether or not Alternate Digit Inversion (ADI) will be applied to the data transmitted and received on the circuit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER adiOn(1), adiOff(2)  

nnciE1DefaultData 1.3.6.1.4.1.123.2.21.1.1.9
The value that is to be transmitted on the circuit when it is not connected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OneByte  

nnciE1FirstCode 1.3.6.1.4.1.123.2.21.1.1.10
The nnciE1FirstCode object is one of two which determines the signalling that will be sent during the Trunk-Conditioning process. This object determines the signalling that will be sent during a timed-break, if one is applied.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

nnciE1SecondCode 1.3.6.1.4.1.123.2.21.1.1.11
The nnciE1SecondCode object is the second of two objects which determines the signalling that will be sent during the Trunk-Conditioning process. This object determines the signalling that will be sent for the duration of the trunk-conditioning process, following the timed-break.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

nnciE1PartOfSuperRate 1.3.6.1.4.1.123.2.21.1.1.13
This parameter is used to form a circular linked list of circuit numbers which make up a superrate connection. It contains the circuit number of the next circuit in the superrate connection or zero if the circuit is not part of a super-rate group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  CircuitNumber  

nnciE1BitsUsed 1.3.6.1.4.1.123.2.21.1.1.14
A bitmap which indicates which bits of the E1 circuit are to be used for data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

nnciE1SuperRateCircuitMap 1.3.6.1.4.1.123.2.21.1.1.21
When written to, this object builds the circularly-linked list of circuits represented by the one bits in the value written. When read, this object returns the bit map corresponding to the super-rate group of which this circuit is a member
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciE1SuperRateNumCircuits 1.3.6.1.4.1.123.2.21.1.1.22
When written to, this object builds the circularly-linked list of circuits to represent the super-rate group which begins at this circuit and contains the specified number of circuits. When read, this object returns the number of circuits in the super-rate group of which this circuit is a member.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciSdcTable 1.3.6.1.4.1.123.2.72.1
This table contains all of the configuration and status information for a Synchronous Data Module circuit.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciSdcTableEntry

nnciSdcTableEntry 1.3.6.1.4.1.123.2.72.1.1
A list of all of the configuration and status information required for a Synchronous Data Module circuit.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciSdcTableEntry  

nnciSdcInterfaceControl 1.3.6.1.4.1.123.2.72.1.1.1
Determines the gender (DTE/DCE) of the specified circuit. The gender is used to a) control the operation and interpretation of the control leads and determine the source of clocks for the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dce(0), dte(16)  

nnciSdcInterfaceSpeed 1.3.6.1.4.1.123.2.72.1.1.2
This object determines the speed of the specified interface in multiples of 800 bits/s. When the interface is in Data Terminal Equipment (DTE) mode (see nnciSdcInterfaceControl), the interface will run at the speed of the supplied clocks, regardless of the value of this object.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciSdcLeadsDefaultOn 1.3.6.1.4.1.123.2.72.1.1.3
This controls the state of the control leads on the specified interface. The control leads that are affected by this object are determined by a) the type of the interface and b) the mode (or gender) of the interface. The leads specified by this object are asserted towards the attached equipment. If there is a conflict between the leads that are 'defaulted on' and those that are 'defaulted off', the value of this object is taken to be correct.
Status: mandatory Access: read-write
OBJECT-TYPE    
  ControlLeads  

nnciSdcLeadDefaultOff 1.3.6.1.4.1.123.2.72.1.1.4
The interface control leads specified by this object are de-asserted towards the attached equipment.
Status: mandatory Access: read-write
OBJECT-TYPE    
  ControlLeads  

nnciSdcInterfaceStatus 1.3.6.1.4.1.123.2.72.1.1.5
This object reports the current status of the control leads associated with the specified interface. The meanings of the bits reported by this object depend on the type and gender of the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  ControlLeads  

nnciHdlcTable 1.3.6.1.4.1.123.2.66.1
This table contains all of the configuration, status and statistical information required for an HDLC circuit.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciHdlcTableEntry

nnciHdlcTableEntry 1.3.6.1.4.1.123.2.66.1.1
A list of all of the configuration, status and statistical information required for an HDLC circuit.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciHdlcTableEntry  

nnciHdlcBytesTransmitted 1.3.6.1.4.1.123.2.66.1.1.1
A count of data and padding bytes that were successfully transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedCounter  

nnciHdlcFramesTransmitted 1.3.6.1.4.1.123.2.66.1.1.2
The number of frames that were successfully transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedCounter  

nnciHdlcRxGoodBytes 1.3.6.1.4.1.123.2.66.1.1.3
The number of bytes in frames that were successfully received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedCounter  

nnciHdlcRxGoodFrames 1.3.6.1.4.1.123.2.66.1.1.4
The number of frames that were successfully received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedCounter  

nnciHdlcUnderrun 1.3.6.1.4.1.123.2.66.1.1.5
The number of frames that should have been transmitted by the station, but could not be transmitted due to an internal MAC sublayer transmit error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedCounter  

nnciHdlcCRCError 1.3.6.1.4.1.123.2.66.1.1.6
The number of frames that contained an integral number of bytes but did not pass the frame sequence.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedCounter  

nnciHdlcAlignmentError 1.3.6.1.4.1.123.2.66.1.1.7
The number of frames that did not contain an integral number of bytes and did not pass the frame sequence.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedCounter  

nnciHdlcOverrun 1.3.6.1.4.1.123.2.66.1.1.8
The number of frames which should have been received by the station, but could not be accepted due to an internal MAC sublayer receive error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedCounter  

nnciHdlcAbort 1.3.6.1.4.1.123.2.66.1.1.9
The number of the number of times that a minimum of seven consecutive ones was received during frame reception.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedCounter  

nnciHdlcSinceLastReset 1.3.6.1.4.1.123.2.66.1.1.11
This object indicates the elapsed time in hundredths of a second since the HDLC device's statistical counters were last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedTime  

nnciHdlcApplication 1.3.6.1.4.1.123.2.66.1.1.12
This object indicates the elapsed time in hundredths of a second since the HDLC device's statistical counters were last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(0), cpss(1), bridge(2), frameStream(3)  

nnciBridgeTable 1.3.6.1.4.1.123.2.55.1
This table contains all of the configuration information for a Bridge.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciBridgeTableEntry

nnciBridgeTableEntry 1.3.6.1.4.1.123.2.55.1.1
A list of all of the configuration information required for a Bridge.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciBridgeTableEntry  

nnciBrdgAddress 1.3.6.1.4.1.123.2.55.1.1.3
The data-link layer address to which messages destined for the bridge should be sent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

nnciBrdgUptime 1.3.6.1.4.1.123.2.55.1.1.4
The elapsed time in hundredths of a second since the bridge entity was last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedTime  

nnciBrdgInterfaceCount 1.3.6.1.4.1.123.2.55.1.1.5
The number of interfaces which are programmed to be used for/by the bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciBrdgMaxInterfaceCount 1.3.6.1.4.1.123.2.55.1.1.6
The maximum possible number of interfaces supported by the bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciBrdgMapCircuitToInterface 1.3.6.1.4.1.123.2.55.1.1.7
Which interface the specified device belongs to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

nnciBridgeStPhase1 1.3.6.1.4.1.123.2.61.1
OBJECT IDENTIFIER    

nnciBridgeStPhase1GroupOne 1.3.6.1.4.1.123.2.61.1.1
OBJECT IDENTIFIER    

nnciBrdgStFramesFiltered 1.3.6.1.4.1.123.2.61.1.1.4
The number of frames received by the bridge and discarded based on information in the address filter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedCounter  

nnciBrdgStFramesForwarded 1.3.6.1.4.1.123.2.61.1.1.5
The number of frames received by the bridge, not discarded and forwarded to a single destination.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedCounter  

nnciBrdgStFramesFlooded 1.3.6.1.4.1.123.2.61.1.1.6
The number of frames received by the bridge, not discarded, but re-transmitted on all interfaces
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedCounter  

nnciBrdgStTimeSinceLastReset 1.3.6.1.4.1.123.2.61.1.1.11
The elapsed time in hundredths of a second since the bridge's statistical counters were last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedTime  

nnciFilterTable 1.3.6.1.4.1.123.2.62.1
This table contains all of the configuration and status information related to the filtering mechanism of a Transparent Bridge.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciFilterTableEntry

nnciFilterTableEntry 1.3.6.1.4.1.123.2.62.1.1
A list of all of the configuration and status information related to the filtering mechanism of a Transparent Bridge.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciFilterTableEntry  

nnciFilterReset 1.3.6.1.4.1.123.2.62.1.1.1
This object forces the bridge to reset the filtering database by first removing all of the entries from the filter and then re-initializing it with the entries from the permanent database. A get on this object will always return zero
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nop(0), reset(1)  

nnciFilterLearn 1.3.6.1.4.1.123.2.62.1.1.2
This object determines whether the address filter will learn the source addresses of frames transmitted on networks to which it is directly attached.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER doNotLearn(0), learn(1)  

nnciFilterPermDBChange 1.3.6.1.4.1.123.2.62.1.1.4
This object indicates that the permanent database entries have changed since the last filter reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER same-as-before(0), changed(1)  

nnciFilterPermDBMaxEntries 1.3.6.1.4.1.123.2.62.1.1.5
This object indicates the maximum number of entries that may be placed in the permanent database of the bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciFilterPermDBEntryCount 1.3.6.1.4.1.123.2.62.1.1.6
This object returns the number of entries currently in the permanent database.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciFilterPermDBContents 1.3.6.1.4.1.123.2.62.1.1.7
This object provides access to the contents of the permanent database. The modifier is the entry number which can range from 1 to FILTER-PermDBEntryCount. If an attempt is made to access an entry that is not defined, an error will be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FilterEntry  

nnciFilterAddPermDBEntry 1.3.6.1.4.1.123.2.62.1.1.8
This object provides a way to add an entry to the permanent database of the bridge. If the maximum size of the permanent database is exceeded, an error will be returned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  FilterEntry  

nnciFilterDeletePermDBEntry 1.3.6.1.4.1.123.2.62.1.1.9
This object provides a way to delete an entry from the permanent database of the bridge. If the specified entry does not exist, an error will be returned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  FilterEntry  

nnciFilterAFMaxEntries 1.3.6.1.4.1.123.2.62.1.1.10
This object stores the maximum number of entries that may be placed in the address filter. The number includes both entries copied from the permanent database and learned entries.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciFilterAFEntryLifetime 1.3.6.1.4.1.123.2.62.1.1.11
This object determined the lifetime of an entry in the address filter. Any entry that is present in the filter but not repeated within n nnciFilterAFEntryLifetime will be deleted from the filter. If the Spanning Tree Protocol is used, TBD this value of STP-ForwardDelay used to age the filter entries.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciFilterAFEntryCount 1.3.6.1.4.1.123.2.62.1.1.12
This object returns the number of entries currently in the address filter. This can be used in conjunction with nnciFilterAFContents to obtain the current contents of the address filter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciFilterAFContents 1.3.6.1.4.1.123.2.62.1.1.13
This object provides access tot he current contents of the address filter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FilterEntry  

nnciFilterForwardMatrix 1.3.6.1.4.1.123.2.62.1.1.14
This object determines any restrictions on bridged traffic flow from a particular interface to all of the other interfaces. The restrictions are organized as a bit vector where the values are either permit or deny. The value of nnciFilterForwardMatrix [i,j] must be permit if any frame originating on interface i may be transmitted on interface j.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciFilterFloodUnicastMatrix 1.3.6.1.4.1.123.2.62.1.1.15
This object determines the handling of a unicast frame with an unrecognized destination. The bridge normally floods such frames on all interfaces except the one on which the frame was received. This object can be used to prevent frames being flooded onto specific interfaces. The restrictions are organized as a bit vector for each interface, where the values are either permit or deny.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciFilterTakeSnapShot 1.3.6.1.4.1.123.2.62.1.1.17
A set with a value of snapshot will make a copy of the address filter that can be accessed by gets from nnciFilterContents
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nop(0), snapshot(1)  

nnciFilterFloodMulticastMatrix 1.3.6.1.4.1.123.2.62.1.1.18
This object determines the handling of a multicast frame with an unrecognized destination. The bridge normally floods such frames on all interfaces except the one on which the frame was received. This object can be used to prevent frames being flooded onto specific interfaces. The restrictions are organized as a bit vector for each interface, where the values are either permit or deny.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciFilterFloodBroadcastMatrix 1.3.6.1.4.1.123.2.62.1.1.19
This object determines the handling of a broadcast frame with an unrecognized destination. The bridge normally floods such frames on all interfaces except the one on which the frame was received. This object can be used to prevent frames being flooded onto specific interfaces. The restrictions are organized as a bit vector for each interface, where the values are either permit or deny.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciFilterPermNVDBContents 1.3.6.1.4.1.123.2.62.1.1.20
This object provides access to the permanent entries stored in NVM, it is used to provide a degree of indirection through the permanent entry vector necessary for minimal manipulation of the database during deletion of permanent entries.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FilterEntry  

nnciFilterDeleteAllPermEntries 1.3.6.1.4.1.123.2.62.1.1.21
This object provides a way to delete all permanent entries from the database in one operation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciStpTable 1.3.6.1.4.1.123.2.63.1
This table contains all of the configuration and status information relating to the operation of the 802.1d Spanning Tree Protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NnciStpTableEntry

nnciStpTableEntry 1.3.6.1.4.1.123.2.63.1.1
A list of all of the configuration and status information relating to the operation of the 802.1d Spanning Tree Protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NnciStpTableEntry  

nnciStpEnable 1.3.6.1.4.1.123.2.63.1.1.1
This object enables or disables the Spanning Tree Protocol. If the protocol is disabled, the bridge acts as a simple bridge, which routes packets based only on information in the address filter. Working without the Spanning Tree Protocol may lead to loops in the network topology and is not recommended. The remaining objects in this section are only defined when the Spanning Tree Protocol is enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER stpOff(0), stpOn(1)  

nnciStpBridgePriority 1.3.6.1.4.1.123.2.63.1.1.2
This object determines the role of the bridge in the spanning tree. It is used to decide which bridge in the network should be the root, which bridges should be active, and which bridges should operate in a standby mode. By changing the bridge priority, one can affect the configuration of the spanning tree. Bridges with smaller priority values are preferentially active i.e. smaller values indicate higher priorities. The bridge priority forms the upper two bytes of the bridge identifier used by the Spanning Tree Protocol.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciStpRoot 1.3.6.1.4.1.123.2.63.1.1.3
This object identifies the bridge that is the root of the spanning tree.
Status: mandatory Access: read-only
OBJECT-TYPE    
  BridgeIdentifier  

nnciStpRootPathCost 1.3.6.1.4.1.123.2.63.1.1.4
This cost of a path is the sum of the costs of the individual hops along the path to the root, where the cost of a hop is a user-assignable object usually related to the speed of the physical link (speed in Mbits/sec) - see also nnciStpInterfaceCost.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciStpRootInterface 1.3.6.1.4.1.123.2.63.1.1.5
This object indicates the interface currently used to send messages to the root bridge. It is chosen as the interface which provides the least-cost path to the root.
Status: mandatory Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

nnciStpMaxAge 1.3.6.1.4.1.123.2.63.1.1.6
This object defines the maximum permissible age in seconds of the configuration information held for each interface. If the information becomes older than nnciStpMaxAge, without being updated by another configuration message from the root bridge, it is discarded, and the bridge attempts to become the designated bridge for that link. In this way, failures of the root or other bridges are detected. (See also nnciStpMyMaxAge).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciStpHelloTime 1.3.6.1.4.1.123.2.63.1.1.7
This object is the value of the HelloTimer used by the root bridge. The present Spanning Tree protocol propogates this value, but the bridges never use it; they use nnciStpMyHelloTime instead.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciStpForwardDelay 1.3.6.1.4.1.123.2.63.1.1.8
This object defines the number of seconds that an interface is kept in the listening or learning state before being moved to the next state. If a topology change has been detected (i.e., nnciStpTopologyChange is true), then this value is also used as the maximum lifetime of entries in the address filter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciStpMyMaxAge 1.3.6.1.4.1.123.2.63.1.1.9
This object is assigned to nnciStpMaxAge if this bridge becomes the root of the spanning tree.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciStpMyHelloTime 1.3.6.1.4.1.123.2.63.1.1.10
This object is the interval between transmission of configuration BPDUs (also called Hello messages) by the bridge. This object is also assigned to nnciStpHelloTime if this bridge becomes the root of the Spanning Tree.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciStpMyForwardDelay 1.3.6.1.4.1.123.2.63.1.1.11
This object is assigned to nnciStpForwardDelay if this bridge becomes the root of the Spanning Tree.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciStpTopologyChangeDetected 1.3.6.1.4.1.123.2.63.1.1.12
If this object is true, then this bridge has detected a topology change recently and is sending topology change notifications (TCNs) to the root bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

nnciStpSendingTopologyChange 1.3.6.1.4.1.123.2.63.1.1.13
If this object is true, then the bridge has recently received a configuration BPDU with the topology change flag set. This indicates that the bridge has been notified (or has itself detected) a topology change, and all bridges in the network should use nnciStpForwardDelay as the aging time of entries in the filtering database for as long as the flag is set.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

nnciStpTimeSinceLastTopologyChange 1.3.6.1.4.1.123.2.63.1.1.14
This object provides the elapsed time in seconds since the last change in network topology. This object is set to zero when a bridge reset occurs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  ExtendedTime  

nnciStpTopologyChanges 1.3.6.1.4.1.123.2.63.1.1.15
This object indicates the number of times that the topology change flag has been set to true since the last bridge reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

nnciStpTopologyChangeAck 1.3.6.1.4.1.123.2.63.1.1.16
This flag indicates whether the topology change acknowledge flag should be set in the next hello message generated on this interface. Setting this flag acknowledges the receipt of a topology change notification (TCN) from another bridge on the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

nnciStpInterfacePriority 1.3.6.1.4.1.123.2.63.1.1.17
This object is a user-settable priority assigned to each interface. The interface priority allows the network manager to indicate that a given interface should be preferentially used for forwarding messages. Interfaces with smaller numbers (higher priorities) are preferentially used for bridge traffic.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciStpInterfaceCost 1.3.6.1.4.1.123.2.63.1.1.18
This object indicates the relative cost of sending a frame out on a given interface. It is computed in the following manner. If nnciStpCostMultiplier is non-zero, then nnciStpInterfaceCost = (nnciStpCostMultiplier/100) * (10^9 / ifSpeed). If nnciStpCostMultiplier is zero, then nnciStpInterfaceCost = nnciStpUserAssignedCost. In this way, the cost of an interface can either track the bandwidth allocated, or be assigned a fixed value. Note that the value is not allowed to be zero.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciStpDesignatedBridge 1.3.6.1.4.1.123.2.63.1.1.19
This object specifies the designated bridge for the link (LAN or WAN) attached to the interface. Specifically, it is the id of the designated bridge. The designated bridge for a link is chosen as the bridge with the least-cost path to the root.
Status: mandatory Access: read-only
OBJECT-TYPE    
  BridgeIdentifier  

nnciStpDesignatedInterface 1.3.6.1.4.1.123.2.63.1.1.20
This object indicates the interface that the bridge given by nnciStpDesignatedBridge uses to send configuration messages over the link (LAN or WAN). Specifically, it is the id of the interface (i.e., the concatenation of the interface priority and the interface address). This object is of interest if the designated bridge has more than one interface connected to the link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

nnciStpDesignatedRoot 1.3.6.1.4.1.123.2.63.1.1.21
This object indicates who the designated bridge thinks is the root (i.e., what the value of nnciStpRoot is on the bridge given by nnciStpDesignateBridge). This object will only differ from nnciStpRoot when the topology of the spanning tree is changing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  BridgeIdentifier  

nnciStpDesignatedCost 1.3.6.1.4.1.123.2.63.1.1.22
This object provides the cost of the cheapest path between nnciStpDesignatedBridge and nnciStpDesignatedRoot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nnciStpConfigurationMessagePending 1.3.6.1.4.1.123.2.63.1.1.23
If this object is true, then a configuration BPDU has been queued for transmission due to the transmission of another configuration BPDU within the last second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

nnciStpAllowableDeviations 1.3.6.1.4.1.123.2.63.1.1.24
This object specifies those deviations from the 802.1d document that will be tolerated by the bridge. If the bit in the specified position is 1, then that deviation will be allowed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciStpCostMultiplier 1.3.6.1.4.1.123.2.63.1.1.25
This object is the weight assigned to the default cost, expressed as a percentage. That is, a multiplier of 50 means the interface should have half its default cost as determined by its speed. See the description of nnciStpInterfaceCost for more details.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nnciStpUserAssignedCost 1.3.6.1.4.1.123.2.63.1.1.26
This object is used to determine the cost assigned to a interface. See the description of nnciStpInterfaceCost for the details.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER