NNC-EXT-PM-STATISTICS-MIB

File: NNC-EXT-PM-STATISTICS-MIB.mib (60980 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IF-MIB NNCGNI0001-SMI ATM-MIB
NNC-INTERVAL-STATISTICS-TC-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE TEXTUAL-CONVENTION
MODULE-COMPLIANCE OBJECT-GROUP ifIndex
nncExtensions NncExtCounter64 atmVplVpi
atmVclVci NncExtIntvlStateType NncExtAbsIntvlNumberType
NncExtRelIntvlNumberType

Defined Types

NncExtPmCellFlowDirType  
This is used to indicate the direction of cell flow. Link describes cells which are traveling to or from an endpoint via the physical interface. Matrix describes cells which are traveling to or from an endpoint via the switching fabric.
TEXTUAL-CONVENTION    
  INTEGER link(1), matrix(2)  

NncExtPmTestType  
This is used to indicate the type of PM test being performed: Segment or End-to-end.
TEXTUAL-CONVENTION    
  INTEGER segment(1), end2end(2)  

NncExtPm15MinCurrentEntry  
SEQUENCE    
  nncExtPm15MinCurrentCellFlow NncExtPmCellFlowDirType
  nncExtPm15MinCurrentTest NncExtPmTestType
  nncExtPm15MinCurrentState NncExtIntvlStateType
  nncExtPm15MinCurrentAbsoluteIntervalNumber NncExtAbsIntvlNumberType
  nncExtPm15MinCurrentSECBs NncExtCounter64
  nncExtPm15MinCurrentLostCellsClp0And1 NncExtCounter64
  nncExtPm15MinCurrentLostCellsClp0 NncExtCounter64
  nncExtPm15MinCurrentMisinsertedCells NncExtCounter64
  nncExtPm15MinCurrentCellsClp0And1 NncExtCounter64
  nncExtPm15MinCurrentCellsClp0 NncExtCounter64
  nncExtPm15MinCurrentImpairedBlocks NncExtCounter64
  nncExtPm15MinCurrentTotalLostCellsClp0And1 NncExtCounter64
  nncExtPm15MinCurrentTotalLostCellsClp0 NncExtCounter64
  nncExtPm15MinCurrentIBWithCellLossMisinsert NncExtCounter64
  nncExtPm15MinCurrentCellLossRatioClp0And1 NncExtCounter64
  nncExtPm15MinCurrentCellLossRatioClp0 NncExtCounter64

NncExtPm15MinIntervalEntry  
SEQUENCE    
  nncExtPm15MinIntervalCellFlow NncExtPmCellFlowDirType
  nncExtPm15MinIntervalTest NncExtPmTestType
  nncExtPm15MinIntervalNumber NncExtRelIntvlNumberType
  nncExtPm15MinIntervalState NncExtIntvlStateType
  nncExtPm15MinIntervalAbsoluteIntervalNumber NncExtAbsIntvlNumberType
  nncExtPm15MinIntervalSECBs NncExtCounter64
  nncExtPm15MinIntervalLostCellsClp0And1 NncExtCounter64
  nncExtPm15MinIntervalLostCellsClp0 NncExtCounter64
  nncExtPm15MinIntervalMisinsertedCells NncExtCounter64
  nncExtPm15MinIntervalCellsClp0And1 NncExtCounter64
  nncExtPm15MinIntervalCellsClp0 NncExtCounter64
  nncExtPm15MinIntervalImpairedBlocks NncExtCounter64
  nncExtPm15MinIntervalTotalLostCellsClp0And1 NncExtCounter64
  nncExtPm15MinIntervalTotalLostCellsClp0 NncExtCounter64
  nncExtPm15MinIntervalIBWithCellLossMisinsert NncExtCounter64
  nncExtPm15MinIntervalCellLossRatioClp0And1 NncExtCounter64
  nncExtPm15MinIntervalCellLossRatioClp0 NncExtCounter64

NncExtPm24HrCurrentEntry  
SEQUENCE    
  nncExtPm24HrCurrentCellFlow NncExtPmCellFlowDirType
  nncExtPm24HrCurrentTest NncExtPmTestType
  nncExtPm24HrCurrentState NncExtIntvlStateType
  nncExtPm24HrCurrentAbsoluteIntervalNumber NncExtAbsIntvlNumberType
  nncExtPm24HrCurrentSECBs NncExtCounter64
  nncExtPm24HrCurrentErroredCells NncExtCounter64
  nncExtPm24HrCurrentLostCellsClp0And1 NncExtCounter64
  nncExtPm24HrCurrentLostCellsClp0 NncExtCounter64
  nncExtPm24HrCurrentMisinsertedCells NncExtCounter64
  nncExtPm24HrCurrentCellsClp0And1 NncExtCounter64
  nncExtPm24HrCurrentCellsClp0 NncExtCounter64
  nncExtPm24HrCurrentImpairedBlocks NncExtCounter64
  nncExtPm24HrCurrentTotalLostCellsClp0And1 NncExtCounter64
  nncExtPm24HrCurrentTotalLostCellsClp0 NncExtCounter64
  nncExtPm24HrCurrentSECBErrored NncExtCounter64
  nncExtPm24HrCurrentSECBMisinserted NncExtCounter64
  nncExtPm24HrCurrentIBWithCellLossMisinsert NncExtCounter64
  nncExtPm24HrCurrentCellLossRatioClp0And1 NncExtCounter64
  nncExtPm24HrCurrentCellLossRatioClp0 NncExtCounter64

NncExtPm24HrIntervalEntry  
SEQUENCE    
  nncExtPm24HrIntervalCellFlow NncExtPmCellFlowDirType
  nncExtPm24HrIntervalTest NncExtPmTestType
  nncExtPm24HrIntervalNumber NncExtRelIntvlNumberType
  nncExtPm24HrIntervalState NncExtIntvlStateType
  nncExtPm24HrIntervalAbsoluteIntervalNumber NncExtAbsIntvlNumberType
  nncExtPm24HrIntervalSECBs NncExtCounter64
  nncExtPm24HrIntervalErroredCells NncExtCounter64
  nncExtPm24HrIntervalLostCellsClp0And1 NncExtCounter64
  nncExtPm24HrIntervalLostCellsClp0 NncExtCounter64
  nncExtPm24HrIntervalMisinsertedCells NncExtCounter64
  nncExtPm24HrIntervalCellsClp0And1 NncExtCounter64
  nncExtPm24HrIntervalCellsClp0 NncExtCounter64
  nncExtPm24HrIntervalImpairedBlocks NncExtCounter64
  nncExtPm24HrIntervalTotalLostCellsClp0And1 NncExtCounter64
  nncExtPm24HrIntervalTotalLostCellsClp0 NncExtCounter64
  nncExtPm24HrIntervalSECBErrored NncExtCounter64
  nncExtPm24HrIntervalSECBMisinserted NncExtCounter64
  nncExtPm24HrIntervalIBWithCellLossMisinsert NncExtCounter64
  nncExtPm24HrIntervalCellLossRatioClp0And1 NncExtCounter64
  nncExtPm24HrIntervalCellLossRatioClp0 NncExtCounter64

Defined Values

nncExtPmStatistics 1.3.6.1.4.1.123.3.65
This module contains the definitions for statistics collected for OAM Performance Monitoring. The definition and requirement for these statistics are found in GR-1248-CORE. In addition, Cell Loss Ratio has been added as part of the Newbridge extension. This MIB module contains the following tables: OAM PM 15 Minute Current Table OAM PM 15 Minute Interval Table OAM PM 24 Hour Current Table OAM PM 24 Hour Interval Table These tables are heavily influenced by the definition of VPL/VCL described in rfc1695. The number of intervals supported is dependent upon resource availibility on any given product, but should nominally be 32 for 15 Minute intervals and 2 for 24 Hour intervals. To avoid building in massive amounts of storage, some products may adopt a bulk collection scheme. Intervals: Statistics on the performance of VPL/VCLs are collected over a historical stratum of up to a maximum of M intervals. The value of M is a function of a product's storage capability. For example, on the 36170 product, M = 32 for 15 Minute interval. The 15 Minute intervals are aligned to the quarter of one hour of a wall clock. The current interval spans back to the last 15 minute tick on the wall clock. Continuing along the timeline from that point is the most recently completed interval and has an index of 1. The previous interval has an index of 2 and so on. Note that the oldest interval may be incomplete since the statistic collection may have been enabled offset to the quarter or one hour tick. t 0 -1i -2i -3i ===========|===========|===========|===========|=========== current N = 1 N = 2 N = 3 N = 4 ... N = M interval Performance Monitoring Demarcation Values: As defined in GR-1248-CORE, three demarcation values are defined to evaluate the condition of a PM cell block. These are M errored, M lost and M misinserted. These values are configurable on a system-wide basis. Where applicable, the definition of a statistics object in this module will refer to one or more of these values.
MODULE-IDENTITY    

nncExtPmStatisticsObjects 1.3.6.1.4.1.123.3.65.1
OBJECT IDENTIFIER    

nncExtPmStatisticsTraps 1.3.6.1.4.1.123.3.65.2
OBJECT IDENTIFIER    

nncExtPmStatisticsGroups 1.3.6.1.4.1.123.3.65.3
OBJECT IDENTIFIER    

nncExtPmStatisticsCompliances 1.3.6.1.4.1.123.3.65.4
OBJECT IDENTIFIER    

nncExtPm15MinCurrentTable 1.3.6.1.4.1.123.3.65.1.1
This table contains objects for OAM Performance Monitoring of an endpoint (VP or VC) during the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NncExtPm15MinCurrentEntry

nncExtPm15MinCurrentEntry 1.3.6.1.4.1.123.3.65.1.1.1
An entry in the 15 minute current statistics table. Each row contains current statistics for an endpoint collecting PM statistics. Note that for a VP endpoint, the VCI value is 0.
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtPm15MinCurrentEntry  

nncExtPm15MinCurrentCellFlow 1.3.6.1.4.1.123.3.65.1.1.1.1
Link or matrix cell flow
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtPmCellFlowDirType  

nncExtPm15MinCurrentTest 1.3.6.1.4.1.123.3.65.1.1.1.2
Segment or end-to-end test
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtPmTestType  

nncExtPm15MinCurrentState 1.3.6.1.4.1.123.3.65.1.1.1.3
The state of the current interval. The object provides a status for those entries which have been reset by the user, or have been subject to a wall clock time change.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtIntvlStateType  

nncExtPm15MinCurrentAbsoluteIntervalNumber 1.3.6.1.4.1.123.3.65.1.1.1.4
The absolute interval number of this interval.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtAbsIntvlNumberType  

nncExtPm15MinCurrentSECBs 1.3.6.1.4.1.123.3.65.1.1.1.5
Severely Errored Cell Blocks. This counter is incremented by one for each PM cell block when M errored, M lost or M misinserted is exceeded.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinCurrentLostCellsClp0And1 1.3.6.1.4.1.123.3.65.1.1.1.6
Lost 0+1 User Information Cells. For each PM cell block, if the number of Lost 0+1 User Information Cells does not exceed M lost, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinCurrentLostCellsClp0 1.3.6.1.4.1.123.3.65.1.1.1.7
Lost 0 User Information Cells. For each PM cell block, if the inferred number of Lost 0 User Information Cells (the smaller value of Lost 0 or 0+1 cells) does not exceed M lost, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinCurrentMisinsertedCells 1.3.6.1.4.1.123.3.65.1.1.1.8
Misinserted User Information Cells. For each PM cell block, if the number of excess User Information Cells does not exceed M misinserted, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinCurrentCellsClp0And1 1.3.6.1.4.1.123.3.65.1.1.1.9
Number of Transmitted 0+1 User Information Cells. For each PM cell block, the number of 0+1 User Information Cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinCurrentCellsClp0 1.3.6.1.4.1.123.3.65.1.1.1.10
Number of Transmitted 0 User Information Cells. For each PM cell block, the number of 0 User Information Cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinCurrentImpairedBlocks 1.3.6.1.4.1.123.3.65.1.1.1.11
Impaired Blocks. This counter is incremented by one when a PM cell block has at least one impairment of any type.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinCurrentTotalLostCellsClp0And1 1.3.6.1.4.1.123.3.65.1.1.1.12
Total Lost 0+1 User Information Cells. For each PM cell block, the number of Lost 0+1 User Information Cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinCurrentTotalLostCellsClp0 1.3.6.1.4.1.123.3.65.1.1.1.13
Total Lost 0 User Information Cells. For each PM cell block, the inferred number of Lost 0 User Information Cells (the smaller value of Lost 0 or 0+1 cells) is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinCurrentIBWithCellLossMisinsert 1.3.6.1.4.1.123.3.65.1.1.1.14
Number of Impaired Blocks with Cell Loss/ Misinsertion. For each PM cell block, the number of lost or misinserted cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinCurrentCellLossRatioClp0And1 1.3.6.1.4.1.123.3.65.1.1.1.15
Cell Loss Ratio 0+1. Ratio of cell loss calculated by ((Total Lost 0+1 User Information Cells) / (Number of Transmitted 0+1 User Information Cells)) * 1000000000. No consideration is made for cells discarded or tagged by UPC.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinCurrentCellLossRatioClp0 1.3.6.1.4.1.123.3.65.1.1.1.16
Cell Loss Ratio 0. Ratio of cell loss calculated by ((Total Lost 0 User Information Cells) / (Number of Transmitted 0 User Information Cells)) * 1000000000. No consideration is made for cells discarded or tagged by UPC.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinIntervalTable 1.3.6.1.4.1.123.3.65.1.2
This table contains objects for OAM Performance Monitoring of an endpoint (VP or VC) over a historical stratum of M 15 minute intervals.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NncExtPm15MinIntervalEntry

nncExtPm15MinIntervalEntry 1.3.6.1.4.1.123.3.65.1.2.1
An entry in the 15 minute interval statistics table. Each row contains interval statistics for an endpoint collecting PM statistics. Note that for a VP endpoint, the VCI value is 0.
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtPm15MinIntervalEntry  

nncExtPm15MinIntervalCellFlow 1.3.6.1.4.1.123.3.65.1.2.1.1
Link or matrix cell flow
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtPmCellFlowDirType  

nncExtPm15MinIntervalTest 1.3.6.1.4.1.123.3.65.1.2.1.2
Segment or end-to-end test
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtPmTestType  

nncExtPm15MinIntervalNumber 1.3.6.1.4.1.123.3.65.1.2.1.3
The interval number (N) of the statistics in this row.
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtRelIntvlNumberType  

nncExtPm15MinIntervalState 1.3.6.1.4.1.123.3.65.1.2.1.4
The state of the interval represented by this row. The object provides a status for those entries which have been reset by the user, or have been subject to a wall clock time change.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtIntvlStateType  

nncExtPm15MinIntervalAbsoluteIntervalNumber 1.3.6.1.4.1.123.3.65.1.2.1.5
The absolute interval number of this interval.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtAbsIntvlNumberType  

nncExtPm15MinIntervalSECBs 1.3.6.1.4.1.123.3.65.1.2.1.6
Severely Errored Cell Blocks. This counter is incremented by one for each PM cell block when M errored, M lost or M misinserted is exceeded.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinIntervalLostCellsClp0And1 1.3.6.1.4.1.123.3.65.1.2.1.7
Lost 0+1 User Information Cells. For each PM cell block, if the number of Lost 0+1 User Information Cells does not exceed M lost, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinIntervalLostCellsClp0 1.3.6.1.4.1.123.3.65.1.2.1.8
Lost 0 User Information Cells. For each PM cell block, if the inferred number of Lost 0 User Information Cells (the smaller value of Lost 0 or 0+1 cells) does not exceed M lost, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinIntervalMisinsertedCells 1.3.6.1.4.1.123.3.65.1.2.1.9
Misinserted User Information Cells. For each PM cell block, if the number of excess User Information Cells does not exceed M misinserted, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinIntervalCellsClp0And1 1.3.6.1.4.1.123.3.65.1.2.1.10
Number of Transmitted 0+1 User Information Cells. For each PM cell block, the number of 0+1 User Information Cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinIntervalCellsClp0 1.3.6.1.4.1.123.3.65.1.2.1.11
Number of Transmitted 0 User Information Cells. For each PM cell block, the number of 0 User Information Cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinIntervalImpairedBlocks 1.3.6.1.4.1.123.3.65.1.2.1.12
Impaired Blocks. This counter is incremented by one when a PM cell block has at least one impairment of any type.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinIntervalTotalLostCellsClp0And1 1.3.6.1.4.1.123.3.65.1.2.1.13
Total Lost 0+1 User Information Cells. For each PM cell block, the number of Lost 0+1 User Information Cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinIntervalTotalLostCellsClp0 1.3.6.1.4.1.123.3.65.1.2.1.14
Total Lost 0 User Information Cells. For each PM cell block, the inferred number of Lost 0 User Information Cells (the smaller value of Lost 0 or 0+1 cells) is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinIntervalIBWithCellLossMisinsert 1.3.6.1.4.1.123.3.65.1.2.1.15
Number of Impaired Blocks with Cell Loss/ Misinsertion. For each PM cell block, the number of lost or misinserted cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinIntervalCellLossRatioClp0And1 1.3.6.1.4.1.123.3.65.1.2.1.16
Cell Loss Ratio 0+1. Ratio of cell loss calculated by ((Total Lost 0+1 User Information Cells) / (Number of Transmitted 0+1 User Information Cells)) * 1000000000. No consideration is made for cells discarded or tagged by UPC.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinIntervalCellLossRatioClp0 1.3.6.1.4.1.123.3.65.1.2.1.17
Cell Loss Ratio 0. Ratio of cell loss calculated by ((Total Lost 0 User Information Cells) / (Number of Transmitted 0 User Information Cells)) * 1000000000. No consideration is made for cells discarded or tagged by UPC.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentTable 1.3.6.1.4.1.123.3.65.1.3
This table contains objects for OAM Performance Monitoring of an endpoint (VP or VC) during the current 24 hour interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NncExtPm24HrCurrentEntry

nncExtPm24HrCurrentEntry 1.3.6.1.4.1.123.3.65.1.3.1
An entry in the 24 hour current statistics table. Each row contains current statistics for an endpoint collecting PM statistics. Note that for a VP endpoint, the VCI value is 0.
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtPm24HrCurrentEntry  

nncExtPm24HrCurrentCellFlow 1.3.6.1.4.1.123.3.65.1.3.1.1
Link or matrix cell flow
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtPmCellFlowDirType  

nncExtPm24HrCurrentTest 1.3.6.1.4.1.123.3.65.1.3.1.2
Segment or end-to-end test
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtPmTestType  

nncExtPm24HrCurrentState 1.3.6.1.4.1.123.3.65.1.3.1.3
The state of the current interval. The object provides a status for those entries which have been reset by the user, or have been subject to a wall clock time change.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtIntvlStateType  

nncExtPm24HrCurrentAbsoluteIntervalNumber 1.3.6.1.4.1.123.3.65.1.3.1.4
The absolute interval number of this interval.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtAbsIntvlNumberType  

nncExtPm24HrCurrentSECBs 1.3.6.1.4.1.123.3.65.1.3.1.5
Severely Errored Cell Blocks. This counter is incremented by one for each PM cell block when M errored, M lost or M misinserted is exceeded.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentErroredCells 1.3.6.1.4.1.123.3.65.1.3.1.6
Errored Cells. For each PM cell block, if the number of errored cells does not exceed M errored, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentLostCellsClp0And1 1.3.6.1.4.1.123.3.65.1.3.1.7
Lost 0+1 User Information Cells. For each PM cell block, if the number of Lost 0+1 User Information Cells does not exceed M lost, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentLostCellsClp0 1.3.6.1.4.1.123.3.65.1.3.1.8
Lost 0 User Information Cells. For each PM cell block, if the inferred number of Lost 0 User Information Cells (the smaller value of Lost 0 or 0+1 cells) does not exceed M lost, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentMisinsertedCells 1.3.6.1.4.1.123.3.65.1.3.1.9
Misinserted User Information Cells. For each PM cell block, if the number of excess User Information Cells does not exceed M misinserted, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentCellsClp0And1 1.3.6.1.4.1.123.3.65.1.3.1.10
Number of Transmitted 0+1 User Information Cells. For each PM cell block, the number of 0+1 User Information Cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentCellsClp0 1.3.6.1.4.1.123.3.65.1.3.1.11
Number of Transmitted 0 User Information Cells. For each PM cell block, the number of 0 User Information Cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentImpairedBlocks 1.3.6.1.4.1.123.3.65.1.3.1.12
Impaired Blocks. This counter is incremented by one when a PM cell block has at least one impairment of any type.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentTotalLostCellsClp0And1 1.3.6.1.4.1.123.3.65.1.3.1.13
Total Lost 0+1 User Information Cells. For each PM cell block, the number of Lost 0+1 User Information Cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentTotalLostCellsClp0 1.3.6.1.4.1.123.3.65.1.3.1.14
Total Lost 0 User Information Cells. For each PM cell block, the inferred number of Lost 0 User Information Cells (the smaller value of Lost 0 or 0+1 cells) is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentSECBErrored 1.3.6.1.4.1.123.3.65.1.3.1.15
SECB Errored (i.e. SECB due to bit errors). This counter is incremented by one for each PM cell block when M errored is exceeded.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentSECBMisinserted 1.3.6.1.4.1.123.3.65.1.3.1.16
SECB Misinserted (i.e. SECB due to misinserted cells). This counter is incremented by one for each PM cell block when M misinserted is exceeded.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentIBWithCellLossMisinsert 1.3.6.1.4.1.123.3.65.1.3.1.17
Number of Impaired Blocks with Cell Loss/ Misinsertion. For each PM cell block, the number of lost or misinserted cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentCellLossRatioClp0And1 1.3.6.1.4.1.123.3.65.1.3.1.18
Cell Loss Ratio 0+1. Ratio of cell loss calculated by ((Total Lost 0+1 User Information Cells) / (Number of Transmitted 0+1 User Information Cells)) * 1000000000. No consideration is made for cells discarded or tagged by UPC.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrCurrentCellLossRatioClp0 1.3.6.1.4.1.123.3.65.1.3.1.19
Cell Loss Ratio 0. Ratio of cell loss calculated by ((Total Lost 0 User Information Cells) / (Number of Transmitted 0 User Information Cells)) * 1000000000. No consideration is made for cells discarded or tagged by UPC.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalTable 1.3.6.1.4.1.123.3.65.1.4
This table contains objects for OAM Performance Monitoring of an endpoint (VP or VC) over a historical stratum of N 24 hour intervals.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NncExtPm24HrIntervalEntry

nncExtPm24HrIntervalEntry 1.3.6.1.4.1.123.3.65.1.4.1
An entry in the 24 hour interval statistics table. Each row contains interval statistics for an endpoint collecting PM statistics. Note that for a VP endpoint, the VCI value is 0.
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtPm24HrIntervalEntry  

nncExtPm24HrIntervalCellFlow 1.3.6.1.4.1.123.3.65.1.4.1.1
Link or matrix cell flow
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtPmCellFlowDirType  

nncExtPm24HrIntervalTest 1.3.6.1.4.1.123.3.65.1.4.1.2
Segment or end-to-end test
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtPmTestType  

nncExtPm24HrIntervalNumber 1.3.6.1.4.1.123.3.65.1.4.1.3
The interval number (N) of the statistics in this row.
Status: current Access: not-accessible
OBJECT-TYPE    
  NncExtRelIntvlNumberType  

nncExtPm24HrIntervalState 1.3.6.1.4.1.123.3.65.1.4.1.4
The state of the interval represented by this row. The object provides a status for those entries which have been reset by the user, or have been subject to a wall clock time change.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtIntvlStateType  

nncExtPm24HrIntervalAbsoluteIntervalNumber 1.3.6.1.4.1.123.3.65.1.4.1.5
The absolute interval number of this interval.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtAbsIntvlNumberType  

nncExtPm24HrIntervalSECBs 1.3.6.1.4.1.123.3.65.1.4.1.6
Severely Errored Cell Blocks. This counter is incremented by one for each PM cell block when M errored, M lost or M misinserted is exceeded.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalErroredCells 1.3.6.1.4.1.123.3.65.1.4.1.7
Errored Cells. For each PM cell block, if the number of errored cells does not exceed M errored, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalLostCellsClp0And1 1.3.6.1.4.1.123.3.65.1.4.1.8
Lost 0+1 User Information Cells. For each PM cell block, if the number of Lost 0+1 User Information Cells does not exceed M lost, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalLostCellsClp0 1.3.6.1.4.1.123.3.65.1.4.1.9
Lost 0 User Information Cells. For each PM cell block, if the inferred number of Lost 0 User Information Cells (the smaller value of Lost 0 or 0+1 cells) does not exceed M lost, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalMisinsertedCells 1.3.6.1.4.1.123.3.65.1.4.1.10
Misinserted User Information Cells. For each PM cell block, if the number of excess User Information Cells does not exceed M misinserted, then this number is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalCellsClp0And1 1.3.6.1.4.1.123.3.65.1.4.1.11
Number of Transmitted 0+1 User Information Cells. For each PM cell block, the number of 0+1 User Information Cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalCellsClp0 1.3.6.1.4.1.123.3.65.1.4.1.12
Number of Transmitted 0 User Information Cells. For each PM cell block, the number of 0 User Information Cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalImpairedBlocks 1.3.6.1.4.1.123.3.65.1.4.1.13
Impaired Blocks. This counter is incremented by one when a PM cell block has at least one impairment of any type.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalTotalLostCellsClp0And1 1.3.6.1.4.1.123.3.65.1.4.1.14
Total Lost 0+1 User Information Cells. For each PM cell block, the number of Lost 0+1 User Information Cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalTotalLostCellsClp0 1.3.6.1.4.1.123.3.65.1.4.1.15
Total Lost 0 User Information Cells. For each PM cell block, the inferred number of Lost 0 User Information Cells (the smaller value of Lost 0 or 0+1 cells) is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalSECBErrored 1.3.6.1.4.1.123.3.65.1.4.1.16
SECB Errored (i.e. SECB due to bit errors). This counter is incremented by one for each PM cell block when M errored is exceeded.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalSECBMisinserted 1.3.6.1.4.1.123.3.65.1.4.1.17
SECB Misinserted (i.e. SECB due to misinserted cells). This counter is incremented by one for each PM cell block when M misinserted is exceeded.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalIBWithCellLossMisinsert 1.3.6.1.4.1.123.3.65.1.4.1.18
Number of Impaired Blocks with Cell Loss/ Misinsertion. For each PM cell block, the number of lost or misinserted cells is added to this counter.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalCellLossRatioClp0And1 1.3.6.1.4.1.123.3.65.1.4.1.19
Cell Loss Ratio 0+1. Ratio of cell loss calculated by ((Total Lost 0+1 User Information Cells) / (Number of Transmitted 0+1 User Information Cells)) * 1000000000. No consideration is made for cells discarded or tagged by UPC.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm24HrIntervalCellLossRatioClp0 1.3.6.1.4.1.123.3.65.1.4.1.20
Cell Loss Ratio 0. Ratio of cell loss calculated by ((Total Lost 0 User Information Cells) / (Number of Transmitted 0 User Information Cells)) * 1000000000. No consideration is made for cells discarded or tagged by UPC.
Status: current Access: read-only
OBJECT-TYPE    
  NncExtCounter64  

nncExtPm15MinCurrentGroup 1.3.6.1.4.1.123.3.65.3.1
A collection of objects providing current 15 min PM statistics for a PM sink point.
Status: current Access: read-only
OBJECT-GROUP    

nncExtPm15MinIntervalGroup 1.3.6.1.4.1.123.3.65.3.2
A collection of objects providing interval 15 min PM statistics for a PM sink point.
Status: current Access: read-only
OBJECT-GROUP    

nncExtPm24HrCurrentGroup 1.3.6.1.4.1.123.3.65.3.3
A collection of objects providing current 24 hour PM statistics for a PM sink point.
Status: current Access: read-only
OBJECT-GROUP    

nncExtPm24HrIntervalGroup 1.3.6.1.4.1.123.3.65.3.4
A collection of objects providing interval 24 hour PM statistics for a PM sink point.
Status: current Access: read-only
OBJECT-GROUP    

nncExtPmStatisticsCompliance 1.3.6.1.4.1.123.3.65.4.1
The compliance statement for Newbridge OAM Performance Monitoring extension.
Status: current Access: read-only
MODULE-COMPLIANCE