Nortel-MsCarrier-MscPassport-DisdnTS014MIB

File: Nortel-MsCarrier-MscPassport-DisdnTS014MIB.mib (29383 bytes)

Imported modules

RFC-1212 Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB Nortel-MsCarrier-MscPassport-StandardTextualConventionsMIB
Nortel-MsCarrier-MscPassport-TextualConventionsMIB Nortel-MsCarrier-MscPassport-DataIsdnMIB

Imported symbols

OBJECT-TYPE mscPassportMIBs DisplayString
StorageType RowStatus Unsigned32
NonReplicated Link mscDataSigChanIndex
mscDataSigChan

Defined Types

MscDataSigChanTS014RowStatusEntry  
SEQUENCE    
  mscDataSigChanTS014RowStatus RowStatus
  mscDataSigChanTS014ComponentName DisplayString
  mscDataSigChanTS014StorageType StorageType
  mscDataSigChanTS014Index NonReplicated

MscDataSigChanTS014L2Entry  
SEQUENCE    
  mscDataSigChanTS014T23 Unsigned32
  mscDataSigChanTS014T200 Unsigned32
  mscDataSigChanTS014N200 Unsigned32
  mscDataSigChanTS014T203 Unsigned32
  mscDataSigChanTS014N201 Unsigned32
  mscDataSigChanTS014CircuitSwitchedK Unsigned32

MscDataSigChanTS014ProvEntry  
SEQUENCE    
  mscDataSigChanTS014Side INTEGER

MscDataSigChanTS014OperEntry  
SEQUENCE    
  mscDataSigChanTS014ActiveChannels Unsigned32
  mscDataSigChanTS014PeakActiveChannels Unsigned32
  mscDataSigChanTS014DChanStatus INTEGER

MscDataSigChanTS014ToolsEntry  
SEQUENCE    
  mscDataSigChanTS014Tracing OCTET STRING

MscDataSigChanTS014FramerRowStatusEntry  
SEQUENCE    
  mscDataSigChanTS014FramerRowStatus RowStatus
  mscDataSigChanTS014FramerComponentName DisplayString
  mscDataSigChanTS014FramerStorageType StorageType
  mscDataSigChanTS014FramerIndex NonReplicated

MscDataSigChanTS014FramerProvEntry  
SEQUENCE    
  mscDataSigChanTS014FramerInterfaceName Link

MscDataSigChanTS014FramerStateEntry  
SEQUENCE    
  mscDataSigChanTS014FramerAdminState INTEGER
  mscDataSigChanTS014FramerOperationalState INTEGER
  mscDataSigChanTS014FramerUsageState INTEGER

MscDataSigChanTS014FramerStatsEntry  
SEQUENCE    
  mscDataSigChanTS014FramerFrmToIf Unsigned32
  mscDataSigChanTS014FramerFrmFromIf Unsigned32
  mscDataSigChanTS014FramerOctetFromIf Unsigned32
  mscDataSigChanTS014FramerAborts Unsigned32
  mscDataSigChanTS014FramerCrcErrors Unsigned32
  mscDataSigChanTS014FramerLrcErrors Unsigned32
  mscDataSigChanTS014FramerNonOctetErrors Unsigned32
  mscDataSigChanTS014FramerOverruns Unsigned32
  mscDataSigChanTS014FramerUnderruns Unsigned32
  mscDataSigChanTS014FramerLargeFrmErrors Unsigned32

Defined Values

disdnTS014MIB 1.3.6.1.4.1.562.36.2.2.114
OBJECT IDENTIFIER    

mscDataSigChanTS014 1.3.6.1.4.1.562.36.2.1.120.9
OBJECT IDENTIFIER    

mscDataSigChanTS014RowStatusTable 1.3.6.1.4.1.562.36.2.1.120.9.1
This entry controls the addition and deletion of mscDataSigChanTS014 components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanTS014RowStatusEntry

mscDataSigChanTS014RowStatusEntry 1.3.6.1.4.1.562.36.2.1.120.9.1.1
A single entry in the table represents a single mscDataSigChanTS014 component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanTS014RowStatusEntry  

mscDataSigChanTS014RowStatus 1.3.6.1.4.1.562.36.2.1.120.9.1.1.1
This variable is used as the basis for SNMP naming of mscDataSigChanTS014 components. These components can be added and deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

mscDataSigChanTS014ComponentName 1.3.6.1.4.1.562.36.2.1.120.9.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mscDataSigChanTS014StorageType 1.3.6.1.4.1.562.36.2.1.120.9.1.1.4
This variable represents the storage type value for the mscDataSigChanTS014 tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

mscDataSigChanTS014Index 1.3.6.1.4.1.562.36.2.1.120.9.1.1.10
This variable represents the index for the mscDataSigChanTS014 tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

mscDataSigChanTS014L2Table 1.3.6.1.4.1.562.36.2.1.120.9.11
This group represents the provisionable Layer 2 attributes of the Q931 CCITT protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanTS014L2Entry

mscDataSigChanTS014L2Entry 1.3.6.1.4.1.562.36.2.1.120.9.11.1
An entry in the mscDataSigChanTS014L2Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanTS014L2Entry  

mscDataSigChanTS014T23 1.3.6.1.4.1.562.36.2.1.120.9.11.1.1
This attribute specifies the layer2 enable request timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..15  

mscDataSigChanTS014T200 1.3.6.1.4.1.562.36.2.1.120.9.11.1.2
This attribute specifies the maximum time between a layer 2 frame and its acknowledgement
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..20  

mscDataSigChanTS014N200 1.3.6.1.4.1.562.36.2.1.120.9.11.1.3
This attribute specifies the maximum number of re-transmissions of a layer2 frame.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..8  

mscDataSigChanTS014T203 1.3.6.1.4.1.562.36.2.1.120.9.11.1.4
This attribute specifies the maximum time that a no layer 2 traffic situation can last. Expiry triggers a check on whether the far end is a live.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 2..40  

mscDataSigChanTS014N201 1.3.6.1.4.1.562.36.2.1.120.9.11.1.5
This attribute specifies the maximum number of octets in an information field.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 4..260  

mscDataSigChanTS014CircuitSwitchedK 1.3.6.1.4.1.562.36.2.1.120.9.11.1.6
This attribute specifies the maximum number of frames for B channel use.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..632  

mscDataSigChanTS014ProvTable 1.3.6.1.4.1.562.36.2.1.120.9.13
This group defines the general options of the d-channel signalling link.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanTS014ProvEntry

mscDataSigChanTS014ProvEntry 1.3.6.1.4.1.562.36.2.1.120.9.13.1
An entry in the mscDataSigChanTS014ProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanTS014ProvEntry  

mscDataSigChanTS014Side 1.3.6.1.4.1.562.36.2.1.120.9.13.1.1
This attribute specifies whether the layer 2 HDLC interface is the network or user side of the connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER network(1), user(2)  

mscDataSigChanTS014OperTable 1.3.6.1.4.1.562.36.2.1.120.9.15
This group provides the operational attributes for the signalling protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanTS014OperEntry

mscDataSigChanTS014OperEntry 1.3.6.1.4.1.562.36.2.1.120.9.15.1
An entry in the mscDataSigChanTS014OperTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanTS014OperEntry  

mscDataSigChanTS014ActiveChannels 1.3.6.1.4.1.562.36.2.1.120.9.15.1.1
This attribute indicates the number of currently active channels. This includes data and voice channels.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..128  

mscDataSigChanTS014PeakActiveChannels 1.3.6.1.4.1.562.36.2.1.120.9.15.1.4
This attribute indicates the maximum number of channels that have been active on this signalling channel during the last polling period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..128  

mscDataSigChanTS014DChanStatus 1.3.6.1.4.1.562.36.2.1.120.9.15.1.7
This attribute indicates the state of the D-channel. outOfService means that there is no layer 2 or layer 3 connectivity to the PBX. establishing means that the signalling channel is attempting to stage the layer 2. established means that the layer 2 is enabled. If the signalling channel stays in the established state, then it is waiting for a restart from the PBX. enabling means that the resources for processing calls are being initialized. If the signalling channel stays in the enabling state then it is waiting for a restart acknowledgement from the PBX. inService means that the resources for processing calls are available. restarting means that the resources for call processing are being rei- initialized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER outOfService(0), establishing(1), established(2), enabling(3), inService(4), restarting(5)  

mscDataSigChanTS014ToolsTable 1.3.6.1.4.1.562.36.2.1.120.9.16
This group contains a series of operational attributes which turn on and off several kinds of tracing.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanTS014ToolsEntry

mscDataSigChanTS014ToolsEntry 1.3.6.1.4.1.562.36.2.1.120.9.16.1
An entry in the mscDataSigChanTS014ToolsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanTS014ToolsEntry  

mscDataSigChanTS014Tracing 1.3.6.1.4.1.562.36.2.1.120.9.16.1.1
This attribute defines which types of tracing are active for this signalling channel. The tracing messages are sent to the debug stream. To see the messages the agentQueue attribute in Col/debug must be greater than 0 and a Telnet NMIS session must list the debug stream in in its data streams (ex. set nmis telnet session/1 dataStreams debug). Different types of tracing can be enabled simultaneously. Note that tracing consumes additional CPU resources and will slow down call processing on a heavily loaded card. If there is message block exhaustion tracing will be suspended for a period and then automatically reenabled. An alarm is generated on tracing suspension and resumption. This mechanism protects the function processor against excessive numbers of tracing messages. Types of tracing include: protocolErrors - get details of any protocol errors which are occuring. Protocol errors are also reported in summary form as alarms. q931Summary - Summary of the Q.931 messages on the signalling link, including certain call details (calling number, called number, release codes). q931Hex - Q.931 messages displayed in hex format. Useful to determine protocol compliance in case of errors reported on local or remote ends. q931Symbolic - Q.931 messages parsed to give maximum detail. Useful for understanding content of messages flowing on the link. portHex - Messages in hex format being sent and received on the link. Description of bits: protocolErrors(0) q931Summary(1) q931Hex(2) q931Symbolic(3) portHex(4)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1)  

mscDataSigChanTS014Framer 1.3.6.1.4.1.562.36.2.1.120.9.2
OBJECT IDENTIFIER    

mscDataSigChanTS014FramerRowStatusTable 1.3.6.1.4.1.562.36.2.1.120.9.2.1
This entry controls the addition and deletion of mscDataSigChanTS014Framer components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanTS014FramerRowStatusEntry

mscDataSigChanTS014FramerRowStatusEntry 1.3.6.1.4.1.562.36.2.1.120.9.2.1.1
A single entry in the table represents a single mscDataSigChanTS014Framer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanTS014FramerRowStatusEntry  

mscDataSigChanTS014FramerRowStatus 1.3.6.1.4.1.562.36.2.1.120.9.2.1.1.1
This variable is used as the basis for SNMP naming of mscDataSigChanTS014Framer components. These components cannot be added nor deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowStatus  

mscDataSigChanTS014FramerComponentName 1.3.6.1.4.1.562.36.2.1.120.9.2.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mscDataSigChanTS014FramerStorageType 1.3.6.1.4.1.562.36.2.1.120.9.2.1.1.4
This variable represents the storage type value for the mscDataSigChanTS014Framer tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

mscDataSigChanTS014FramerIndex 1.3.6.1.4.1.562.36.2.1.120.9.2.1.1.10
This variable represents the index for the mscDataSigChanTS014Framer tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

mscDataSigChanTS014FramerProvTable 1.3.6.1.4.1.562.36.2.1.120.9.2.10
This group contains the base provisioning data for the Framer component. Application or hardware interface specific provisioning data is contained in other provisionable Framer groups.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanTS014FramerProvEntry

mscDataSigChanTS014FramerProvEntry 1.3.6.1.4.1.562.36.2.1.120.9.2.10.1
An entry in the mscDataSigChanTS014FramerProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanTS014FramerProvEntry  

mscDataSigChanTS014FramerInterfaceName 1.3.6.1.4.1.562.36.2.1.120.9.2.10.1.1
This attribute contains a hardware component name. The attribute associates the application with a specific link. This defines the module processor on which Framer's parent component (as well as Framer itself) will run.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Link  

mscDataSigChanTS014FramerStateTable 1.3.6.1.4.1.562.36.2.1.120.9.2.12
This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanTS014FramerStateEntry

mscDataSigChanTS014FramerStateEntry 1.3.6.1.4.1.562.36.2.1.120.9.2.12.1
An entry in the mscDataSigChanTS014FramerStateTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanTS014FramerStateEntry  

mscDataSigChanTS014FramerAdminState 1.3.6.1.4.1.562.36.2.1.120.9.2.12.1.1
This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER locked(0), unlocked(1), shuttingDown(2)  

mscDataSigChanTS014FramerOperationalState 1.3.6.1.4.1.562.36.2.1.120.9.2.12.1.2
This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

mscDataSigChanTS014FramerUsageState 1.3.6.1.4.1.562.36.2.1.120.9.2.12.1.3
This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(0), active(1), busy(2)  

mscDataSigChanTS014FramerStatsTable 1.3.6.1.4.1.562.36.2.1.120.9.2.13
This group contains the operational statistics data for a Framer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscDataSigChanTS014FramerStatsEntry

mscDataSigChanTS014FramerStatsEntry 1.3.6.1.4.1.562.36.2.1.120.9.2.13.1
An entry in the mscDataSigChanTS014FramerStatsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscDataSigChanTS014FramerStatsEntry  

mscDataSigChanTS014FramerFrmToIf 1.3.6.1.4.1.562.36.2.1.120.9.2.13.1.1
This attribute counts the number of frames transmitted to the link interface by Framer. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanTS014FramerFrmFromIf 1.3.6.1.4.1.562.36.2.1.120.9.2.13.1.2
This attribute counts the number of frames received from the link interface by Framer. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanTS014FramerOctetFromIf 1.3.6.1.4.1.562.36.2.1.120.9.2.13.1.3
The number of bytes received from the link interface by Framer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanTS014FramerAborts 1.3.6.1.4.1.562.36.2.1.120.9.2.13.1.4
This attribute counts the total number of aborts received. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanTS014FramerCrcErrors 1.3.6.1.4.1.562.36.2.1.120.9.2.13.1.5
This attribute counts the total number of frames with CRC errors. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanTS014FramerLrcErrors 1.3.6.1.4.1.562.36.2.1.120.9.2.13.1.6
This attribute counts the total number of frames with LRC errors. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanTS014FramerNonOctetErrors 1.3.6.1.4.1.562.36.2.1.120.9.2.13.1.7
This attribute counts the total number of frames that were non octet aligned. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanTS014FramerOverruns 1.3.6.1.4.1.562.36.2.1.120.9.2.13.1.8
This attribute counts the total number of frames received from the link for which overruns occurred. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanTS014FramerUnderruns 1.3.6.1.4.1.562.36.2.1.120.9.2.13.1.9
This attribute counts the total number of frames transmitted to the link for which underruns occurred. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscDataSigChanTS014FramerLargeFrmErrors 1.3.6.1.4.1.562.36.2.1.120.9.2.13.1.10
This attribute counts the total number of frames received which were too large. The frame was longer than 500 bytes. This count wraps to zero after reaching its maximum value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

disdnTS014Group 1.3.6.1.4.1.562.36.2.2.114.1
OBJECT IDENTIFIER    

disdnTS014GroupCA 1.3.6.1.4.1.562.36.2.2.114.1.1
OBJECT IDENTIFIER    

disdnTS014GroupCA02 1.3.6.1.4.1.562.36.2.2.114.1.1.3
OBJECT IDENTIFIER    

disdnTS014GroupCA02A 1.3.6.1.4.1.562.36.2.2.114.1.1.3.2
OBJECT IDENTIFIER    

disdnTS014Capabilities 1.3.6.1.4.1.562.36.2.2.114.3
OBJECT IDENTIFIER    

disdnTS014CapabilitiesCA 1.3.6.1.4.1.562.36.2.2.114.3.1
OBJECT IDENTIFIER    

disdnTS014CapabilitiesCA02 1.3.6.1.4.1.562.36.2.2.114.3.1.3
OBJECT IDENTIFIER    

disdnTS014CapabilitiesCA02A 1.3.6.1.4.1.562.36.2.2.114.3.1.3.2
OBJECT IDENTIFIER