Nortel-MsCarrier-MscPassport-PppMIB

File: Nortel-MsCarrier-MscPassport-PppMIB.mib (90698 bytes)

Imported modules

RFC-1212 Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB Nortel-MsCarrier-MscPassport-StandardTextualConventionsMIB
Nortel-MsCarrier-MscPassport-TextualConventionsMIB

Imported symbols

OBJECT-TYPE mscPassportMIBs mscComponents
Counter32 DisplayString StorageType
RowStatus InterfaceIndex Gauge32
Integer32 Unsigned32 NonReplicated
Link

Defined Types

MscPppRowStatusEntry  
SEQUENCE    
  mscPppRowStatus RowStatus
  mscPppComponentName DisplayString
  mscPppStorageType StorageType
  mscPppIndex Integer32

MscPppCidDataEntry  
SEQUENCE    
  mscPppCustomerIdentifier Unsigned32

MscPppIfEntryEntry  
SEQUENCE    
  mscPppIfAdminStatus INTEGER
  mscPppIfIndex InterfaceIndex

MscPppMpEntry  
SEQUENCE    
  mscPppLinkToProtocolPort Link

MscPppStateEntry  
SEQUENCE    
  mscPppAdminState INTEGER
  mscPppOperationalState INTEGER
  mscPppUsageState INTEGER

MscPppOperStatusEntry  
SEQUENCE    
  mscPppSnmpOperStatus INTEGER

MscPppLnkRowStatusEntry  
SEQUENCE    
  mscPppLnkRowStatus RowStatus
  mscPppLnkComponentName DisplayString
  mscPppLnkStorageType StorageType
  mscPppLnkIndex NonReplicated

MscPppLnkProvEntry  
SEQUENCE    
  mscPppLnkConfigInitialMru Unsigned32
  mscPppLnkConfigMagicNumber INTEGER
  mscPppLnkRestartTimer Unsigned32
  mscPppLnkContinuityMonitor INTEGER
  mscPppLnkNegativeAckTries Unsigned32
  mscPppLnkQualityThreshold Unsigned32
  mscPppLnkQualityWindow Unsigned32
  mscPppLnkTerminateRequestTries Unsigned32
  mscPppLnkConfigureRequestTries Unsigned32

MscPppLnkOperEntry  
SEQUENCE    
  mscPppLnkOperState INTEGER
  mscPppLnkLineCondition INTEGER
  mscPppLnkBadAddresses Counter32
  mscPppLnkBadControls Counter32
  mscPppLnkPacketTooLongs Counter32
  mscPppLnkBadFcss Counter32
  mscPppLnkLocalMru Unsigned32
  mscPppLnkRemoteMru Unsigned32
  mscPppLnkTransmitFcsSize Unsigned32
  mscPppLnkReceiveFcsSize Unsigned32

MscPppLqmRowStatusEntry  
SEQUENCE    
  mscPppLqmRowStatus RowStatus
  mscPppLqmComponentName DisplayString
  mscPppLqmStorageType StorageType
  mscPppLqmIndex NonReplicated

MscPppLqmProvEntry  
SEQUENCE    
  mscPppLqmConfigPeriod Unsigned32
  mscPppLqmConfigStatus INTEGER

MscPppLqmOperEntry  
SEQUENCE    
  mscPppLqmQuality INTEGER
  mscPppLqmInGoodOctets Counter32
  mscPppLqmLocalPeriod Unsigned32
  mscPppLqmRemotePeriod Unsigned32
  mscPppLqmOutLqrs Counter32
  mscPppLqmInLqrs Counter32

MscPppNcpRowStatusEntry  
SEQUENCE    
  mscPppNcpRowStatus RowStatus
  mscPppNcpComponentName DisplayString
  mscPppNcpStorageType StorageType
  mscPppNcpIndex NonReplicated

MscPppNcpBprovEntry  
SEQUENCE    
  mscPppNcpBConfigTinygram INTEGER
  mscPppNcpBConfigLanId INTEGER

MscPppNcpIpOperEntry  
SEQUENCE    
  mscPppNcpIpOperState INTEGER

MscPppNcpBoperEntry  
SEQUENCE    
  mscPppNcpBOperState INTEGER
  mscPppNcpBLocalToRemoteTinygramComp INTEGER
  mscPppNcpBRemoteToLocalTinygramComp INTEGER
  mscPppNcpBLocalToRemoteLanId INTEGER
  mscPppNcpBRemoteToLocalLanId INTEGER

MscPppNcpOperEntry  
SEQUENCE    
  mscPppNcpAppletalkOperState INTEGER
  mscPppNcpIpxOperState INTEGER
  mscPppNcpXnsOperState INTEGER
  mscPppNcpDecnetOperState INTEGER

MscPppNcpBmcEntryRowStatusEntry  
SEQUENCE    
  mscPppNcpBmcEntryRowStatus RowStatus
  mscPppNcpBmcEntryComponentName DisplayString
  mscPppNcpBmcEntryStorageType StorageType
  mscPppNcpBmcEntryMacTypeIndex INTEGER

MscPppNcpBmcEntryProvEntry  
SEQUENCE    
  mscPppNcpBmcEntryLocalStatus INTEGER

MscPppNcpBmEntryRowStatusEntry  
SEQUENCE    
  mscPppNcpBmEntryRowStatus RowStatus
  mscPppNcpBmEntryComponentName DisplayString
  mscPppNcpBmEntryStorageType StorageType
  mscPppNcpBmEntryMacTypeIndex INTEGER

MscPppNcpBmEntryOperEntry  
SEQUENCE    
  mscPppNcpBmEntryLocalStatus INTEGER
  mscPppNcpBmEntryRemoteStatus INTEGER

MscPppFramerRowStatusEntry  
SEQUENCE    
  mscPppFramerRowStatus RowStatus
  mscPppFramerComponentName DisplayString
  mscPppFramerStorageType StorageType
  mscPppFramerIndex NonReplicated

MscPppFramerProvEntry  
SEQUENCE    
  mscPppFramerInterfaceName Link

MscPppFramerStateEntry  
SEQUENCE    
  mscPppFramerAdminState INTEGER
  mscPppFramerOperationalState INTEGER
  mscPppFramerUsageState INTEGER

MscPppFramerStatsEntry  
SEQUENCE    
  mscPppFramerFrmToIf Counter32
  mscPppFramerFrmFromIf Counter32
  mscPppFramerAborts Counter32
  mscPppFramerCrcErrors Counter32
  mscPppFramerLrcErrors Counter32
  mscPppFramerNonOctetErrors Counter32
  mscPppFramerOverruns Counter32
  mscPppFramerUnderruns Counter32
  mscPppFramerLargeFrmErrors Counter32

MscPppFramerUtilEntry  
SEQUENCE    
  mscPppFramerNormPrioLinkUtilToIf Gauge32
  mscPppFramerNormPrioLinkUtilFromIf Gauge32

MscPppLeqRowStatusEntry  
SEQUENCE    
  mscPppLeqRowStatus RowStatus
  mscPppLeqComponentName DisplayString
  mscPppLeqStorageType StorageType
  mscPppLeqIndex NonReplicated

MscPppLeqProvEntry  
SEQUENCE    
  mscPppLeqMaxPackets Unsigned32
  mscPppLeqMaxMsecData Unsigned32
  mscPppLeqMaxPercentMulticast Unsigned32
  mscPppLeqTimeToLive Unsigned32

MscPppLeqStatsEntry  
SEQUENCE    
  mscPppLeqTimedOutPkt Counter32
  mscPppLeqHardwareForcedPkt Counter32
  mscPppLeqForcedPktDiscards Counter32
  mscPppLeqQueuePurgeDiscards Counter32

MscPppLeqTStatsEntry  
SEQUENCE    
  mscPppLeqTotalPktHandled Counter32
  mscPppLeqTotalPktForwarded Counter32
  mscPppLeqTotalPktQueued Counter32
  mscPppLeqTotalMulticastPkt Counter32
  mscPppLeqTotalPktDiscards Counter32

MscPppLeqCStatsEntry  
SEQUENCE    
  mscPppLeqCurrentPktQueued Gauge32
  mscPppLeqCurrentBytesQueued Gauge32
  mscPppLeqCurrentMulticastQueued Gauge32

MscPppLeqThrStatsEntry  
SEQUENCE    
  mscPppLeqQueuePktThreshold Unsigned32
  mscPppLeqPktThresholdExceeded Counter32
  mscPppLeqQueueByteThreshold Unsigned32
  mscPppLeqByteThresholdExceeded Counter32
  mscPppLeqQueueMulticastThreshold Unsigned32
  mscPppLeqMulThresholdExceeded Counter32
  mscPppLeqMemThresholdExceeded Counter32

Defined Values

pppMIB 1.3.6.1.4.1.562.36.2.2.33
OBJECT IDENTIFIER    

mscPpp 1.3.6.1.4.1.562.36.2.1.102
OBJECT IDENTIFIER    

mscPppRowStatusTable 1.3.6.1.4.1.562.36.2.1.102.1
This entry controls the addition and deletion of mscPpp components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppRowStatusEntry

mscPppRowStatusEntry 1.3.6.1.4.1.562.36.2.1.102.1.1
A single entry in the table represents a single mscPpp component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppRowStatusEntry  

mscPppRowStatus 1.3.6.1.4.1.562.36.2.1.102.1.1.1
This variable is used as the basis for SNMP naming of mscPpp components. These components can be added and deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

mscPppComponentName 1.3.6.1.4.1.562.36.2.1.102.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mscPppStorageType 1.3.6.1.4.1.562.36.2.1.102.1.1.4
This variable represents the storage type value for the mscPpp tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

mscPppIndex 1.3.6.1.4.1.562.36.2.1.102.1.1.10
This variable represents the index for the mscPpp tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Integer32 1..65535  

mscPppCidDataTable 1.3.6.1.4.1.562.36.2.1.102.20
This group contains the attribute for a component's Customer Identifier (CID). Refer to the attribute description for a detailed explanation of CIDs.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppCidDataEntry

mscPppCidDataEntry 1.3.6.1.4.1.562.36.2.1.102.20.1
An entry in the mscPppCidDataTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppCidDataEntry  

mscPppCustomerIdentifier 1.3.6.1.4.1.562.36.2.1.102.20.1.1
This attribute holds the Customer Identifier (CID). Every component has a CID. If a component has a cid attribute, the component's CID is the provisioned value of that attribute; otherwise the component inherits the CID of its parent. The top- level component has a CID of 0. Every operator session also has a CID, which is the CID provisioned for the operator's user ID. An operator will see only the stream data for components having a matching CID. Also, the operator will be allowed to issue commands for only those components which have a matching CID. An operator CID of 0 is used to identify the Network Manager (referred to as 'NetMan' in DPN). This CID matches the CID of any component. Values 1 to 8191 inclusive (equivalent to 'basic CIDs' in DPN) may be assigned to specific customers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 0 | 1..8191  

mscPppIfEntryTable 1.3.6.1.4.1.562.36.2.1.102.21
This group contains the provisionable attributes for the ifEntry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppIfEntryEntry

mscPppIfEntryEntry 1.3.6.1.4.1.562.36.2.1.102.21.1
An entry in the mscPppIfEntryTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppIfEntryEntry  

mscPppIfAdminStatus 1.3.6.1.4.1.562.36.2.1.102.21.1.1
The desired state of the interface. The up state indicates the interface is operational. The down state indicates the interface is not operational. The testing state indicates that no operational packets can be passed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

mscPppIfIndex 1.3.6.1.4.1.562.36.2.1.102.21.1.2
This is the index for the IfEntry. Its value is automatically initialized during the provisioning process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  InterfaceIndex 1..65535  

mscPppMpTable 1.3.6.1.4.1.562.36.2.1.102.22
This group contains the base provisioning data for the Media Application component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppMpEntry

mscPppMpEntry 1.3.6.1.4.1.562.36.2.1.102.22.1
An entry in the mscPppMpTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppMpEntry  

mscPppLinkToProtocolPort 1.3.6.1.4.1.562.36.2.1.102.22.1.1
This attribute contains a protocol port component name. The attribute associates the application with a protocol port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Link  

mscPppStateTable 1.3.6.1.4.1.562.36.2.1.102.23
This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppStateEntry

mscPppStateEntry 1.3.6.1.4.1.562.36.2.1.102.23.1
An entry in the mscPppStateTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppStateEntry  

mscPppAdminState 1.3.6.1.4.1.562.36.2.1.102.23.1.1
This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER locked(0), unlocked(1), shuttingDown(2)  

mscPppOperationalState 1.3.6.1.4.1.562.36.2.1.102.23.1.2
This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

mscPppUsageState 1.3.6.1.4.1.562.36.2.1.102.23.1.3
This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(0), active(1), busy(2)  

mscPppOperStatusTable 1.3.6.1.4.1.562.36.2.1.102.24
This group includes the Operational Status attribute. This attribute defines the current operational state of this component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppOperStatusEntry

mscPppOperStatusEntry 1.3.6.1.4.1.562.36.2.1.102.24.1
An entry in the mscPppOperStatusTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppOperStatusEntry  

mscPppSnmpOperStatus 1.3.6.1.4.1.562.36.2.1.102.24.1.1
The current state of the interface. The up state indicates the interface is operational and capable of forwarding packets. The down state indicates the interface is not operational, thus unable to forward packets. testing state indicates that no operational packets can be passed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

mscPppLnk 1.3.6.1.4.1.562.36.2.1.102.2
OBJECT IDENTIFIER    

mscPppLnkRowStatusTable 1.3.6.1.4.1.562.36.2.1.102.2.1
This entry controls the addition and deletion of mscPppLnk components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppLnkRowStatusEntry

mscPppLnkRowStatusEntry 1.3.6.1.4.1.562.36.2.1.102.2.1.1
A single entry in the table represents a single mscPppLnk component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppLnkRowStatusEntry  

mscPppLnkRowStatus 1.3.6.1.4.1.562.36.2.1.102.2.1.1.1
This variable is used as the basis for SNMP naming of mscPppLnk components. These components cannot be added nor deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowStatus  

mscPppLnkComponentName 1.3.6.1.4.1.562.36.2.1.102.2.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mscPppLnkStorageType 1.3.6.1.4.1.562.36.2.1.102.2.1.1.4
This variable represents the storage type value for the mscPppLnk tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

mscPppLnkIndex 1.3.6.1.4.1.562.36.2.1.102.2.1.1.10
This variable represents the index for the mscPppLnk tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

mscPppLnkProvTable 1.3.6.1.4.1.562.36.2.1.102.2.10
This group contains the provisioned attributes for the Ppp Link component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppLnkProvEntry

mscPppLnkProvEntry 1.3.6.1.4.1.562.36.2.1.102.2.10.1
An entry in the mscPppLnkProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppLnkProvEntry  

mscPppLnkConfigInitialMru 1.3.6.1.4.1.562.36.2.1.102.2.10.1.1
This is the initial Maximum Receive Unit (Mru) that the local Ppp entity will advertise to the remote entity. A change to this attribute will not take effect until Ppp is restarted (lock/unlock).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 68..18000  

mscPppLnkConfigMagicNumber 1.3.6.1.4.1.562.36.2.1.102.2.10.1.4
If enabled then the local node will attempt to perform Magic Number negotiation with the remote node. If disabled then this negotiation is not performed. In any event, the local node will comply with any magic number negotiations attempted by the remote node, per the Ppp specification. A change to this attribute will not take effect until Ppp is restarted (lock/unlock).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

mscPppLnkRestartTimer 1.3.6.1.4.1.562.36.2.1.102.2.10.1.6
This is the time, in milliseconds, that Ppp will wait for a response to a configure request or a terminate request before retrying.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1000..10000  

mscPppLnkContinuityMonitor 1.3.6.1.4.1.562.36.2.1.102.2.10.1.7
This attribute turns on/off (enabled/disabled) the Link Continuity Monitor. If set to enabled, periodic keep alive echo packet will be sent over the Ppp link. If set to disabled, no keep alive packets will be sent. A change to this attribute will not take effect until Ppp is restarted (lock/ unlock).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

mscPppLnkNegativeAckTries 1.3.6.1.4.1.562.36.2.1.102.2.10.1.8
This attribute specifies the maximum negative acknowledgments sent to the remote Ppp entity during negotiation before defaulting it's configuration parameters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscPppLnkQualityThreshold 1.3.6.1.4.1.562.36.2.1.102.2.10.1.9
This attribute specifies the minimum allowed line quality before the line is considered too poor to continue operation. The value for this attribute is a percentage measure of the line quality given in integers (10 to 99). The higher the value, the more stringent the line requirements.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 10..99  

mscPppLnkQualityWindow 1.3.6.1.4.1.562.36.2.1.102.2.10.1.10
This attribute specifies the number of seconds used for sampling line quality. If line quality drops below the level set with the qualityThreshold attribute during this window, this instance of Ppp will be marked down until line quality recovers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 10..400  

mscPppLnkTerminateRequestTries 1.3.6.1.4.1.562.36.2.1.102.2.10.1.11
This attribute specifies the maximum terminate requests to be sent, when closing the connection, and not answered before this instance of Ppp enters a closing state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscPppLnkConfigureRequestTries 1.3.6.1.4.1.562.36.2.1.102.2.10.1.12
This attribute specifies the number of configuration requests that will be sent out and not answered before this instance of Ppp enters a listening state. If both sides enter the listening state then the link will not come up. To eliminate this possibility, this attribute should be set to 1000000000. This will ensure that this end of the Ppp link will continue to try until the link is good.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscPppLnkOperTable 1.3.6.1.4.1.562.36.2.1.102.2.11
This group contains the Ppp Link Operational attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppLnkOperEntry

mscPppLnkOperEntry 1.3.6.1.4.1.562.36.2.1.102.2.11.1
An entry in the mscPppLnkOperTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppLnkOperEntry  

mscPppLnkOperState 1.3.6.1.4.1.562.36.2.1.102.2.11.1.1
This is the operational state of the Link Control Protocol. For more information as to the definition of each state see RFC1331 section 5.3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER initial(0), starting(1), closed(2), stopped(3), closing(4), stopping(5), reqsent(6), ackrcvd(7), acksent(8), opened(9)  

mscPppLnkLineCondition 1.3.6.1.4.1.562.36.2.1.102.2.11.1.2
This attribute describes the condition of the physical line that Ppp is running over. ok: The condition of the line is good. looped: The line is looped back on itself, probably at the remote end. noClock: There is a hardware problem with the line. The cable may not be plugged in correctly. badLineCondition: The quality of the line is below the qualityThreshold.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(0), looped(1), noClock(3), badLineCondition(4)  

mscPppLnkBadAddresses 1.3.6.1.4.1.562.36.2.1.102.2.11.1.4
This attribute counts the number of packets received with an incorrect Address Field. If this count is going up quickly, it could indicate that there is a line quality problem or that the remote end is transmitting a protocol other than Ppp. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLnkBadControls 1.3.6.1.4.1.562.36.2.1.102.2.11.1.5
This attribute counts the number of packets received on this link with an incorrect Control Field. If this count is going up quickly, it could indicate that there is a line quality problem or that the remote end is transmitting a protocol other than Ppp. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLnkPacketTooLongs 1.3.6.1.4.1.562.36.2.1.102.2.11.1.6
This attribute counts the number of packets received that have been discarded because their length exceeded the Maximum Receive Unit (Mru). This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLnkBadFcss 1.3.6.1.4.1.562.36.2.1.102.2.11.1.7
This attribute counts the number of packets received that have been discarded due to having an incorrect Frame Check Sequence (Fcs). This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLnkLocalMru 1.3.6.1.4.1.562.36.2.1.102.2.11.1.8
This is the current value of the Maximum Receive Unit (Mru) for the local Ppp Entity. This value is the Mru that the remote entity is using when sending packets to the local Ppp entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 1..2147483648  

mscPppLnkRemoteMru 1.3.6.1.4.1.562.36.2.1.102.2.11.1.9
This is the current value of the Maximum Receive Unit (Mru) for the remote Ppp entity. This value is the Mru that the local entity is using when sending packets to the remote Ppp entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 1..2147483648  

mscPppLnkTransmitFcsSize 1.3.6.1.4.1.562.36.2.1.102.2.11.1.16
This is the size of the Frame Check Sequence (Fcs) in bits that the local node will generate when sending packets to the remote node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..128  

mscPppLnkReceiveFcsSize 1.3.6.1.4.1.562.36.2.1.102.2.11.1.17
This is the size of the Frame Check Sequence (Fcs) in bits that the remote node will generate when sending packets to the local node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..128  

mscPppLqm 1.3.6.1.4.1.562.36.2.1.102.3
OBJECT IDENTIFIER    

mscPppLqmRowStatusTable 1.3.6.1.4.1.562.36.2.1.102.3.1
This entry controls the addition and deletion of mscPppLqm components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppLqmRowStatusEntry

mscPppLqmRowStatusEntry 1.3.6.1.4.1.562.36.2.1.102.3.1.1
A single entry in the table represents a single mscPppLqm component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppLqmRowStatusEntry  

mscPppLqmRowStatus 1.3.6.1.4.1.562.36.2.1.102.3.1.1.1
This variable is used as the basis for SNMP naming of mscPppLqm components. These components cannot be added nor deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowStatus  

mscPppLqmComponentName 1.3.6.1.4.1.562.36.2.1.102.3.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mscPppLqmStorageType 1.3.6.1.4.1.562.36.2.1.102.3.1.1.4
This variable represents the storage type value for the mscPppLqm tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

mscPppLqmIndex 1.3.6.1.4.1.562.36.2.1.102.3.1.1.10
This variable represents the index for the mscPppLqm tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

mscPppLqmProvTable 1.3.6.1.4.1.562.36.2.1.102.3.10
This group contains the provisioned attributes for the Ppp Link Quality Monitor component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppLqmProvEntry

mscPppLqmProvEntry 1.3.6.1.4.1.562.36.2.1.102.3.10.1
An entry in the mscPppLqmProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppLqmProvEntry  

mscPppLqmConfigPeriod 1.3.6.1.4.1.562.36.2.1.102.3.10.1.1
This is the Lqm reporting period that the local Ppp entity will attempt to negotiate with the remote entity, in units of hundredths of a second. A value of '0' will allow the remote Ppp entity to determine the reporting period. A value greater than 180,000 (1/2 hour) will allow the period to be determined dynamically as a function of the transmit data rate. A value from 1-9 will be rounded up to 10 during negotiation. A change to this attribute will not take effect until Ppp is restarted (lock/unlock).
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2147483647  

mscPppLqmConfigStatus 1.3.6.1.4.1.562.36.2.1.102.3.10.1.2
If this attribute is enabled, the local node will attempt to perform Lqm negotiation with the remote node. If it is disabled then this negotiation is not performed. A change to this attribute will not take effect until Ppp is restarted (lock/unlock).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

mscPppLqmOperTable 1.3.6.1.4.1.562.36.2.1.102.3.11
This group contains the operational attributes for the Ppp Link Quality Monitor component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppLqmOperEntry

mscPppLqmOperEntry 1.3.6.1.4.1.562.36.2.1.102.3.11.1
An entry in the mscPppLqmOperTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppLqmOperEntry  

mscPppLqmQuality 1.3.6.1.4.1.562.36.2.1.102.3.11.1.1
This is the current quality of the link as declared by the local Ppp entity's Link-Quality Management modules. A value of good indicates that LinkQualityMonitor configStatus is enabled and Link quality is above Link qualityThreshold. A value of bad indicates that LinkQualityMonitor configStatus is enabled and Link quality is not above Link qualityThreshold. A value of notDetermined indicates that LinkQualityMonitor configStatus is enabled and the quality of the link has not been calculated yet or LinkQualityMonitor configStatus is disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER good(1), bad(2), notDetermined(3)  

mscPppLqmInGoodOctets 1.3.6.1.4.1.562.36.2.1.102.3.11.1.2
This attribute counts the number of good octets received. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLqmLocalPeriod 1.3.6.1.4.1.562.36.2.1.102.3.11.1.3
This is the Lqm reporting period, in hundredths of a second that is in effect for the local Ppp entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 1..4294967295  

mscPppLqmRemotePeriod 1.3.6.1.4.1.562.36.2.1.102.3.11.1.4
This is the Lqm reporting period, in hundredths of a second, that is in effect for the remote Ppp entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 1..4294967295  

mscPppLqmOutLqrs 1.3.6.1.4.1.562.36.2.1.102.3.11.1.5
This attribute counts the number of link quality reports sent out. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLqmInLqrs 1.3.6.1.4.1.562.36.2.1.102.3.11.1.6
This attribute counts the number of link quality reports received. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppNcp 1.3.6.1.4.1.562.36.2.1.102.4
OBJECT IDENTIFIER    

mscPppNcpRowStatusTable 1.3.6.1.4.1.562.36.2.1.102.4.1
This entry controls the addition and deletion of mscPppNcp components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppNcpRowStatusEntry

mscPppNcpRowStatusEntry 1.3.6.1.4.1.562.36.2.1.102.4.1.1
A single entry in the table represents a single mscPppNcp component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppNcpRowStatusEntry  

mscPppNcpRowStatus 1.3.6.1.4.1.562.36.2.1.102.4.1.1.1
This variable is used as the basis for SNMP naming of mscPppNcp components. These components cannot be added nor deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowStatus  

mscPppNcpComponentName 1.3.6.1.4.1.562.36.2.1.102.4.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mscPppNcpStorageType 1.3.6.1.4.1.562.36.2.1.102.4.1.1.4
This variable represents the storage type value for the mscPppNcp tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

mscPppNcpIndex 1.3.6.1.4.1.562.36.2.1.102.4.1.1.10
This variable represents the index for the mscPppNcp tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

mscPppNcpBprovTable 1.3.6.1.4.1.562.36.2.1.102.4.11
This group contains the provisioned attributes for the Bridge Network Control Protocol.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppNcpBprovEntry

mscPppNcpBprovEntry 1.3.6.1.4.1.562.36.2.1.102.4.11.1
An entry in the mscPppNcpBprovTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppNcpBprovEntry  

mscPppNcpBConfigTinygram 1.3.6.1.4.1.562.36.2.1.102.4.11.1.1
If this attribute is set to disabled then the local Bridge Network Control Protocol (Bncp) entity will not initiate the tinygram compression option negotiation. If it is enabled then the local Bncp entity will initiate negotiation of this option. A change to this attribute will not take effect until Ppp is restarted (lock/unlock).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

mscPppNcpBConfigLanId 1.3.6.1.4.1.562.36.2.1.102.4.11.1.4
If this attribute is set to disabled then the local Bncp entity will not initiate the lan identification option negotiation. If it is enabled then the local Bncp entity will initiate negotiation of the option. A change to this attribute will not take effect until Ppp is restarted (lock/unlock).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

mscPppNcpIpOperTable 1.3.6.1.4.1.562.36.2.1.102.4.12
This group contains the Ip Network Control Protocol operational attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppNcpIpOperEntry

mscPppNcpIpOperEntry 1.3.6.1.4.1.562.36.2.1.102.4.12.1
An entry in the mscPppNcpIpOperTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppNcpIpOperEntry  

mscPppNcpIpOperState 1.3.6.1.4.1.562.36.2.1.102.4.12.1.1
This is the operational state of the Ip network protocol. For more information as to the definition of each state see RFC1331 section 5.3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER initial(0), starting(1), closed(2), stopped(3), closing(4), stopping(5), reqsent(6), ackrcvd(7), acksent(8), opened(9)  

mscPppNcpBoperTable 1.3.6.1.4.1.562.36.2.1.102.4.14
This group contains the Bridge Network Control Protocol operational attributes.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppNcpBoperEntry

mscPppNcpBoperEntry 1.3.6.1.4.1.562.36.2.1.102.4.14.1
An entry in the mscPppNcpBoperTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppNcpBoperEntry  

mscPppNcpBOperState 1.3.6.1.4.1.562.36.2.1.102.4.14.1.1
This is the operational status of the bridge network protocol. For more information as to the definition of each state see RFC1331 section 5.3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER initial(0), starting(1), closed(2), stopped(3), closing(4), stopping(5), reqsent(6), ackrcvd(7), acksent(8), opened(9)  

mscPppNcpBLocalToRemoteTinygramComp 1.3.6.1.4.1.562.36.2.1.102.4.14.1.3
This attribute indicates whether the local node will perform tinygram compression when sending packets to the remote entity. If it is disabled then the local entity will not perform tinygram compression. If it is enabled then the local entity will perform tinygram compression.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

mscPppNcpBRemoteToLocalTinygramComp 1.3.6.1.4.1.562.36.2.1.102.4.14.1.4
If this attribute is disabled then the remote entity is not expected to perform tinygram compression. If it is enabled then the remote entity is expected to perform tinygram compression.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

mscPppNcpBLocalToRemoteLanId 1.3.6.1.4.1.562.36.2.1.102.4.14.1.5
This attribute indicates whether the local node will include the lan identification field in transmitted packets or not. If it is disabled then the local node will not transmit this field, enabled means that the field will be transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

mscPppNcpBRemoteToLocalLanId 1.3.6.1.4.1.562.36.2.1.102.4.14.1.6
This attribute indicates whether the remote node has indicated that it will include the lan identification field in transmitted packets or not. If it is disabled then the field will not be transmitted, if enabled then the field will be transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

mscPppNcpOperTable 1.3.6.1.4.1.562.36.2.1.102.4.16
This group contains the operational attributes for any Network Control Protocols other than Ip and Bridge.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppNcpOperEntry

mscPppNcpOperEntry 1.3.6.1.4.1.562.36.2.1.102.4.16.1
An entry in the mscPppNcpOperTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppNcpOperEntry  

mscPppNcpAppletalkOperState 1.3.6.1.4.1.562.36.2.1.102.4.16.1.1
This is the operational state of the AppleTalk network protocol. For more information as to the definition of each state see RFC1331 section 5.3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER initial(0), starting(1), closed(2), stopped(3), closing(4), stopping(5), reqsent(6), ackrcvd(7), acksent(8), opened(9)  

mscPppNcpIpxOperState 1.3.6.1.4.1.562.36.2.1.102.4.16.1.2
This is the operational state of the Ipx network protocol. For more information as to the definition of each state see RFC1331 section 5.3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER initial(0), starting(1), closed(2), stopped(3), closing(4), stopping(5), reqsent(6), ackrcvd(7), acksent(8), opened(9)  

mscPppNcpXnsOperState 1.3.6.1.4.1.562.36.2.1.102.4.16.1.3
This is the operational state of the Xns network protocol. For more information as to the definition of each state see RFC1331 section 5.3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER initial(0), starting(1), closed(2), stopped(3), closing(4), stopping(5), reqsent(6), ackrcvd(7), acksent(8), opened(9)  

mscPppNcpDecnetOperState 1.3.6.1.4.1.562.36.2.1.102.4.16.1.4
This is the operational state of the DecNet network protocol. For more information as to the definition of each state see RFC1331 section 5.3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER initial(0), starting(1), closed(2), stopped(3), closing(4), stopping(5), reqsent(6), ackrcvd(7), acksent(8), opened(9)  

mscPppNcpBmcEntry 1.3.6.1.4.1.562.36.2.1.102.4.2
OBJECT IDENTIFIER    

mscPppNcpBmcEntryRowStatusTable 1.3.6.1.4.1.562.36.2.1.102.4.2.1
This entry controls the addition and deletion of mscPppNcpBmcEntry components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppNcpBmcEntryRowStatusEntry

mscPppNcpBmcEntryRowStatusEntry 1.3.6.1.4.1.562.36.2.1.102.4.2.1.1
A single entry in the table represents a single mscPppNcpBmcEntry component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppNcpBmcEntryRowStatusEntry  

mscPppNcpBmcEntryRowStatus 1.3.6.1.4.1.562.36.2.1.102.4.2.1.1.1
This variable is used as the basis for SNMP naming of mscPppNcpBmcEntry components. These components can be added.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

mscPppNcpBmcEntryComponentName 1.3.6.1.4.1.562.36.2.1.102.4.2.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mscPppNcpBmcEntryStorageType 1.3.6.1.4.1.562.36.2.1.102.4.2.1.1.4
This variable represents the storage type value for the mscPppNcpBmcEntry tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

mscPppNcpBmcEntryMacTypeIndex 1.3.6.1.4.1.562.36.2.1.102.4.2.1.1.10
This variable represents the index for the mscPppNcpBmcEntry tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER ethernet(1), tokenBus(2), tokenRing(3), fddi(4)  

mscPppNcpBmcEntryProvTable 1.3.6.1.4.1.562.36.2.1.102.4.2.10
This group contains the attributes for one entry in the BridgeMediaConfigEntry table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppNcpBmcEntryProvEntry

mscPppNcpBmcEntryProvEntry 1.3.6.1.4.1.562.36.2.1.102.4.2.10.1
An entry in the mscPppNcpBmcEntryProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppNcpBmcEntryProvEntry  

mscPppNcpBmcEntryLocalStatus 1.3.6.1.4.1.562.36.2.1.102.4.2.10.1.1
This attribute indicates whether the local Ppp bridging entity should accept packets of the protocol type identified by the instance value of this component. Setting this attribute to accept allows packets of this protocol type to be accepted. A change to this attribute will not take effect until Ppp is restarted (lock/unlock).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER accept(1)  

mscPppNcpBmEntry 1.3.6.1.4.1.562.36.2.1.102.4.3
OBJECT IDENTIFIER    

mscPppNcpBmEntryRowStatusTable 1.3.6.1.4.1.562.36.2.1.102.4.3.1
*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This entry controls the addition and deletion of mscPppNcpBmEntry components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppNcpBmEntryRowStatusEntry

mscPppNcpBmEntryRowStatusEntry 1.3.6.1.4.1.562.36.2.1.102.4.3.1.1
A single entry in the table represents a single mscPppNcpBmEntry component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppNcpBmEntryRowStatusEntry  

mscPppNcpBmEntryRowStatus 1.3.6.1.4.1.562.36.2.1.102.4.3.1.1.1
This variable is used as the basis for SNMP naming of mscPppNcpBmEntry components. These components cannot be added nor deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowStatus  

mscPppNcpBmEntryComponentName 1.3.6.1.4.1.562.36.2.1.102.4.3.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mscPppNcpBmEntryStorageType 1.3.6.1.4.1.562.36.2.1.102.4.3.1.1.4
This variable represents the storage type value for the mscPppNcpBmEntry tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

mscPppNcpBmEntryMacTypeIndex 1.3.6.1.4.1.562.36.2.1.102.4.3.1.1.10
This variable represents the index for the mscPppNcpBmEntry tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER ethernet(1), tokenBus(2), tokenRing(3), fddi(4)  

mscPppNcpBmEntryOperTable 1.3.6.1.4.1.562.36.2.1.102.4.3.10
*** THIS TABLE CURRENTLY NOT IMPLEMENTED *** This group contains the attributes for one entry in the BridgeMediaEntry table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppNcpBmEntryOperEntry

mscPppNcpBmEntryOperEntry 1.3.6.1.4.1.562.36.2.1.102.4.3.10.1
An entry in the mscPppNcpBmEntryOperTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppNcpBmEntryOperEntry  

mscPppNcpBmEntryLocalStatus 1.3.6.1.4.1.562.36.2.1.102.4.3.10.1.2
This attribute indicates whether the local Ppp bridging entity will accept packets of the protocol type identified by the instance value of this component. A value of accept indicates that packets of this protocol type will be accepted. A value of dontAccept indicates that packets of this type will not be accepted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER accept(1), dontAccept(2)  

mscPppNcpBmEntryRemoteStatus 1.3.6.1.4.1.562.36.2.1.102.4.3.10.1.3
This attribute indicates whether the remote Ppp bridging entity will accept packets of the protocol type identified by the instance value of this component. A value of accept indicates that packets of this protocol type will be accepted. A value of dontAccept indicates that packets of this type will not be accepted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER accept(1), dontAccept(2)  

mscPppFramer 1.3.6.1.4.1.562.36.2.1.102.5
OBJECT IDENTIFIER    

mscPppFramerRowStatusTable 1.3.6.1.4.1.562.36.2.1.102.5.1
This entry controls the addition and deletion of mscPppFramer components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppFramerRowStatusEntry

mscPppFramerRowStatusEntry 1.3.6.1.4.1.562.36.2.1.102.5.1.1
A single entry in the table represents a single mscPppFramer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppFramerRowStatusEntry  

mscPppFramerRowStatus 1.3.6.1.4.1.562.36.2.1.102.5.1.1.1
This variable is used as the basis for SNMP naming of mscPppFramer components. These components cannot be added nor deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RowStatus  

mscPppFramerComponentName 1.3.6.1.4.1.562.36.2.1.102.5.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mscPppFramerStorageType 1.3.6.1.4.1.562.36.2.1.102.5.1.1.4
This variable represents the storage type value for the mscPppFramer tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

mscPppFramerIndex 1.3.6.1.4.1.562.36.2.1.102.5.1.1.10
This variable represents the index for the mscPppFramer tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

mscPppFramerProvTable 1.3.6.1.4.1.562.36.2.1.102.5.10
This group contains the base provisioning data for the Framer component. Application or hardware interface specific provisioning data is contained in other provisionable Framer groups.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppFramerProvEntry

mscPppFramerProvEntry 1.3.6.1.4.1.562.36.2.1.102.5.10.1
An entry in the mscPppFramerProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppFramerProvEntry  

mscPppFramerInterfaceName 1.3.6.1.4.1.562.36.2.1.102.5.10.1.1
This attribute contains a hardware component name. The attribute associates the application with a specific link. This defines the logical processor on which Framer's parent component (as well as Framer itself) will run.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Link  

mscPppFramerStateTable 1.3.6.1.4.1.562.36.2.1.102.5.12
This group contains the three OSI State attributes. The descriptions generically indicate what each state attribute implies about the component. Note that not all the values and state combinations described here are supported by every component which uses this group. For component-specific information and the valid state combinations, refer to NTP 241-7001-150, Passport Operations and Maintenance Guide.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppFramerStateEntry

mscPppFramerStateEntry 1.3.6.1.4.1.562.36.2.1.102.5.12.1
An entry in the mscPppFramerStateTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppFramerStateEntry  

mscPppFramerAdminState 1.3.6.1.4.1.562.36.2.1.102.5.12.1.1
This attribute indicates the OSI Administrative State of the component. The value locked indicates that the component is administratively prohibited from providing services for its users. A Lock or Lock - force command has been previously issued for this component. When the value is locked, the value of usageState must be idle. The value shuttingDown indicates that the component is administratively permitted to provide service to its existing users only. A Lock command was issued against the component and it is in the process of shutting down. The value unlocked indicates that the component is administratively permitted to provide services for its users. To enter this state, issue an Unlock command to this component.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER locked(0), unlocked(1), shuttingDown(2)  

mscPppFramerOperationalState 1.3.6.1.4.1.562.36.2.1.102.5.12.1.2
This attribute indicates the OSI Operational State of the component. The value enabled indicates that the component is available for operation. Note that if adminState is locked, it would still not be providing service. The value disabled indicates that the component is not available for operation. For example, something is wrong with the component itself, or with another component on which this one depends. If the value is disabled, the usageState must be idle.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

mscPppFramerUsageState 1.3.6.1.4.1.562.36.2.1.102.5.12.1.3
This attribute indicates the OSI Usage State of the component. The value idle indicates that the component is not currently in use. The value active indicates that the component is in use and has spare capacity to provide for additional users. The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(0), active(1), busy(2)  

mscPppFramerStatsTable 1.3.6.1.4.1.562.36.2.1.102.5.13
This group contains the operational statistics data for a Framer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppFramerStatsEntry

mscPppFramerStatsEntry 1.3.6.1.4.1.562.36.2.1.102.5.13.1
An entry in the mscPppFramerStatsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppFramerStatsEntry  

mscPppFramerFrmToIf 1.3.6.1.4.1.562.36.2.1.102.5.13.1.1
This attribute counts the number of frames transmitted to the link interface by Framer. Note: This does not include the number of frames transmitted directly to the hardware queue, thus bypassing the Framer component.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppFramerFrmFromIf 1.3.6.1.4.1.562.36.2.1.102.5.13.1.2
This attribute counts the number of frames received from the link interface by Framer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppFramerAborts 1.3.6.1.4.1.562.36.2.1.102.5.13.1.3
This attribute counts the total number of aborts received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppFramerCrcErrors 1.3.6.1.4.1.562.36.2.1.102.5.13.1.4
This attribute counts the total number of frames with CRC errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppFramerLrcErrors 1.3.6.1.4.1.562.36.2.1.102.5.13.1.5
This attribute counts the total number of frames with LRC errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppFramerNonOctetErrors 1.3.6.1.4.1.562.36.2.1.102.5.13.1.6
This attribute counts the total number of frames that were non octet aligned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppFramerOverruns 1.3.6.1.4.1.562.36.2.1.102.5.13.1.7
This attribute counts the total number of frames received from the link for which overruns occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppFramerUnderruns 1.3.6.1.4.1.562.36.2.1.102.5.13.1.8
This attribute counts the total number of frames transmitted to the link for which underruns occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppFramerLargeFrmErrors 1.3.6.1.4.1.562.36.2.1.102.5.13.1.9
This attribute counts the total number of frames received which were too large. The frame execeeded the maximumFrameLengthLimit provisioned attribute or it contained more than the 255 block hardware limit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppFramerUtilTable 1.3.6.1.4.1.562.36.2.1.102.5.14
This group contains the link utilizaiton operational data for a Framer component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppFramerUtilEntry

mscPppFramerUtilEntry 1.3.6.1.4.1.562.36.2.1.102.5.14.1
An entry in the mscPppFramerUtilTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppFramerUtilEntry  

mscPppFramerNormPrioLinkUtilToIf 1.3.6.1.4.1.562.36.2.1.102.5.14.1.1
This attribute is the utilization of the normal priority data sent to the link as a percentage of the available bandwidth on the link. The utilization is the average for the last minute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge32 0..100  

mscPppFramerNormPrioLinkUtilFromIf 1.3.6.1.4.1.562.36.2.1.102.5.14.1.3
This attribute is the utilization of the normal priority data received from the link as a percentage of the available bandwidth on the link. The utilization is the average for the last minute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge32 0..100  

mscPppLeq 1.3.6.1.4.1.562.36.2.1.102.6
OBJECT IDENTIFIER    

mscPppLeqRowStatusTable 1.3.6.1.4.1.562.36.2.1.102.6.1
This entry controls the addition and deletion of mscPppLeq components.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppLeqRowStatusEntry

mscPppLeqRowStatusEntry 1.3.6.1.4.1.562.36.2.1.102.6.1.1
A single entry in the table represents a single mscPppLeq component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppLeqRowStatusEntry  

mscPppLeqRowStatus 1.3.6.1.4.1.562.36.2.1.102.6.1.1.1
This variable is used as the basis for SNMP naming of mscPppLeq components. These components can be added and deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  RowStatus  

mscPppLeqComponentName 1.3.6.1.4.1.562.36.2.1.102.6.1.1.2
This variable provides the component's string name for use with the ASCII Console Interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mscPppLeqStorageType 1.3.6.1.4.1.562.36.2.1.102.6.1.1.4
This variable represents the storage type value for the mscPppLeq tables.
Status: mandatory Access: read-only
OBJECT-TYPE    
  StorageType  

mscPppLeqIndex 1.3.6.1.4.1.562.36.2.1.102.6.1.1.10
This variable represents the index for the mscPppLeq tables.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NonReplicated  

mscPppLeqProvTable 1.3.6.1.4.1.562.36.2.1.102.6.10
This group contains the provisioned attributes for the LinkEmissionQueue component.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppLeqProvEntry

mscPppLeqProvEntry 1.3.6.1.4.1.562.36.2.1.102.6.10.1
An entry in the mscPppLeqProvTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppLeqProvEntry  

mscPppLeqMaxPackets 1.3.6.1.4.1.562.36.2.1.102.6.10.1.1
This attribute specifies the maximum number of packets allowed in the Leq before being discarded. If this attribute is set to zero then the maximum number of packets is calculated from the transmit data rate. This calculated value is placed in queuePktThreshold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2048  

mscPppLeqMaxMsecData 1.3.6.1.4.1.562.36.2.1.102.6.10.1.2
This attribute specifies the maximum number of 'Milliseconds worth of data' allowed in the Leq before packets are discarded. The queueByteThreshold will be calculated from this attribute, based on the transmit data rate.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 100..60000  

mscPppLeqMaxPercentMulticast 1.3.6.1.4.1.562.36.2.1.102.6.10.1.3
This attribute specifies the maximum percentage of multicast packets allowed in the Leq, based on queuePktThreshold, before being discarded. The calculated value will be placed in queueMulticastThreshold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 1..100  

mscPppLeqTimeToLive 1.3.6.1.4.1.562.36.2.1.102.6.10.1.4
This attribute specifies the 'Milliseconds Time To Live' of packets in the Leq. If the timeToLive of a packet expires, it will be discarded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Unsigned32 100..60000  

mscPppLeqStatsTable 1.3.6.1.4.1.562.36.2.1.102.6.11
This group contains Link Emission Queue general statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppLeqStatsEntry

mscPppLeqStatsEntry 1.3.6.1.4.1.562.36.2.1.102.6.11.1
An entry in the mscPppLeqStatsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppLeqStatsEntry  

mscPppLeqTimedOutPkt 1.3.6.1.4.1.562.36.2.1.102.6.11.1.1
This attribute counts the number of packets that have been discarded due to exceeding the timeToLive. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLeqHardwareForcedPkt 1.3.6.1.4.1.562.36.2.1.102.6.11.1.2
This attribute counts the number of hardware forced packets on this instance of Ppp. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLeqForcedPktDiscards 1.3.6.1.4.1.562.36.2.1.102.6.11.1.4
This attribute counts the total number of hardware forced packets that had to be discarded due to link failure. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLeqQueuePurgeDiscards 1.3.6.1.4.1.562.36.2.1.102.6.11.1.5
This attribute counts the total number of packets discarded by a queue purge (i.e. a discarding of all packets on the queue). This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLeqTStatsTable 1.3.6.1.4.1.562.36.2.1.102.6.12
This group contains Link Emission Queue total statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppLeqTStatsEntry

mscPppLeqTStatsEntry 1.3.6.1.4.1.562.36.2.1.102.6.12.1
An entry in the mscPppLeqTStatsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppLeqTStatsEntry  

mscPppLeqTotalPktHandled 1.3.6.1.4.1.562.36.2.1.102.6.12.1.1
This attribute counts the total number of packets handled by the Leq. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLeqTotalPktForwarded 1.3.6.1.4.1.562.36.2.1.102.6.12.1.2
This attribute counts the total number of packets forwarded by the Leq. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLeqTotalPktQueued 1.3.6.1.4.1.562.36.2.1.102.6.12.1.3
This attribute counts the total number of packets that required queuing by the Leq due to transmit congestion. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLeqTotalMulticastPkt 1.3.6.1.4.1.562.36.2.1.102.6.12.1.4
This attribute counts the total number of multicast packets handled by this instance of Ppp. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLeqTotalPktDiscards 1.3.6.1.4.1.562.36.2.1.102.6.12.1.8
This attribute counts the total number of packets that were discarded for this instance of Ppp. This is the sum of timedOutPkt, forcedPktDiscards, queuePurgeDiscards, pktThresholdExceeded, byteThresholdExceeded, mulThresholdExceeded, and memThresholdExceeded. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLeqCStatsTable 1.3.6.1.4.1.562.36.2.1.102.6.13
This group contains Link Emission Queue current statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppLeqCStatsEntry

mscPppLeqCStatsEntry 1.3.6.1.4.1.562.36.2.1.102.6.13.1
An entry in the mscPppLeqCStatsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppLeqCStatsEntry  

mscPppLeqCurrentPktQueued 1.3.6.1.4.1.562.36.2.1.102.6.13.1.1
This attribute counts the current number of packets queued.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge32 0..4294967295  

mscPppLeqCurrentBytesQueued 1.3.6.1.4.1.562.36.2.1.102.6.13.1.2
This attribute counts the current number of bytes queued.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge32 0..4294967295  

mscPppLeqCurrentMulticastQueued 1.3.6.1.4.1.562.36.2.1.102.6.13.1.3
This attribute counts the current number of multicast packets in the queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge32 0..4294967295  

mscPppLeqThrStatsTable 1.3.6.1.4.1.562.36.2.1.102.6.14
This group contains Link Emission Queue threshold statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MscPppLeqThrStatsEntry

mscPppLeqThrStatsEntry 1.3.6.1.4.1.562.36.2.1.102.6.14.1
An entry in the mscPppLeqThrStatsTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MscPppLeqThrStatsEntry  

mscPppLeqQueuePktThreshold 1.3.6.1.4.1.562.36.2.1.102.6.14.1.1
This attribute is the maximum number of packets that can be contained in the queue before being discarded. If maxPackets was set to 0 then this attribute will contain the value that has been calculated based on the transmit data rate. If maxPackets was set to one or more than this attribute will contain that number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscPppLeqPktThresholdExceeded 1.3.6.1.4.1.562.36.2.1.102.6.14.1.2
This attribute counts the number of packets discarded due to the queuePktThreshold being exceeded. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLeqQueueByteThreshold 1.3.6.1.4.1.562.36.2.1.102.6.14.1.3
This attribute is the maximum number of bytes allowed in the queue based on maxMsecData and the transmit data rate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscPppLeqByteThresholdExceeded 1.3.6.1.4.1.562.36.2.1.102.6.14.1.4
This attribute counts the number of packets discarded due to the queueByteThreshold being exceeded. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLeqQueueMulticastThreshold 1.3.6.1.4.1.562.36.2.1.102.6.14.1.5
This attribute is the number of multicast packets allowed in the queue based on maxPercentMulticast and maxPackets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

mscPppLeqMulThresholdExceeded 1.3.6.1.4.1.562.36.2.1.102.6.14.1.6
This attribute counts the number of packets discarded due to the queueMulticastThreshold being exceeded. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

mscPppLeqMemThresholdExceeded 1.3.6.1.4.1.562.36.2.1.102.6.14.1.7
This attribute counts the number of packets discarded due to exceeding the memory usage threshold for Leq. The memory usage threshold is determined by the Leq software, guaranteeing that the Leq does not consume all of the memory. This counter will wrap around to 0 when it exceeds its maximum count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter32  

pppGroup 1.3.6.1.4.1.562.36.2.2.33.1
OBJECT IDENTIFIER    

pppGroupCA 1.3.6.1.4.1.562.36.2.2.33.1.1
OBJECT IDENTIFIER    

pppGroupCA02 1.3.6.1.4.1.562.36.2.2.33.1.1.3
OBJECT IDENTIFIER    

pppGroupCA02A 1.3.6.1.4.1.562.36.2.2.33.1.1.3.2
OBJECT IDENTIFIER    

pppCapabilities 1.3.6.1.4.1.562.36.2.2.33.3
OBJECT IDENTIFIER    

pppCapabilitiesCA 1.3.6.1.4.1.562.36.2.2.33.3.1
OBJECT IDENTIFIER    

pppCapabilitiesCA02 1.3.6.1.4.1.562.36.2.2.33.3.1.3
OBJECT IDENTIFIER    

pppCapabilitiesCA02A 1.3.6.1.4.1.562.36.2.2.33.3.1.3.2
OBJECT IDENTIFIER