OGTRAP-MIB

File: OGTRAP-MIB.mib (11103 bytes)

Imported modules

RFC-1212 RFC-1215 RFC1155-SMI

Imported symbols

OBJECT-TYPE TRAP-TYPE enterprises

Defined Values

opengear 1.3.6.1.4.1.25049
OBJECT IDENTIFIER    

ogLegacyMgmt 1.3.6.1.4.1.25049.2
OBJECT IDENTIFIER    

ogConnectMib 1.3.6.1.4.1.25049.2.10
OBJECT IDENTIFIER    

ogSignalMib 1.3.6.1.4.1.25049.2.11
OBJECT IDENTIFIER    

ogPatternMib 1.3.6.1.4.1.25049.2.12
OBJECT IDENTIFIER    

ogSensorMib 1.3.6.1.4.1.25049.2.13
OBJECT IDENTIFIER    

ogHostMib 1.3.6.1.4.1.25049.2.14
OBJECT IDENTIFIER    

ogFailoverMib 1.3.6.1.4.1.25049.2.15
OBJECT IDENTIFIER    

ogNetUpsMib 1.3.6.1.4.1.25049.2.16
OBJECT IDENTIFIER    

ogDataMib 1.3.6.1.4.1.25049.2.17
OBJECT IDENTIFIER    

ogConnectMibObjects 1.3.6.1.4.1.25049.2.10.10
OBJECT IDENTIFIER    

ogconnEvent 1.3.6.1.4.1.25049.2.10.10.1
OBJECT IDENTIFIER    

ogconnEventTable 1.3.6.1.4.1.25049.2.10.10.1.1
OBJECT IDENTIFIER    

ogconnEventEntry 1.3.6.1.4.1.25049.2.10.10.1.1.1
OBJECT IDENTIFIER    

ogconnEventUsername 1.3.6.1.4.1.25049.2.10.10.1.1.1.10
The user pertaining to the connection event
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogconnEventType 1.3.6.1.4.1.25049.2.10.10.1.1.1.11
The type of connection event
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogconnEventPortNumber 1.3.6.1.4.1.25049.2.10.10.1.1.1.12
Serial port number on which this connection applies
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ogconnEventPortLabel 1.3.6.1.4.1.25049.2.10.10.1.1.1.13
The label for the serial port where the connection occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogconnEventOccurred 1001
The alert sent when a user connection event occurs.
TRAP-TYPE    

ogSignalMibObjects 1.3.6.1.4.1.25049.2.11.10
OBJECT IDENTIFIER    

ogsgnlEvent 1.3.6.1.4.1.25049.2.11.10.1
OBJECT IDENTIFIER    

ogsgnlEventTable 1.3.6.1.4.1.25049.2.11.10.1.1
OBJECT IDENTIFIER    

ogsgnlEventEntry 1.3.6.1.4.1.25049.2.11.10.1.1.1
OBJECT IDENTIFIER    

ogsgnlEventType 1.3.6.1.4.1.25049.2.11.10.1.1.1.10
The particular signal which changed
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogsgnlEventState 1.3.6.1.4.1.25049.2.11.10.1.1.1.11
The current signal state
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogsgnlEventPortNumber 1.3.6.1.4.1.25049.2.11.10.1.1.1.12
Serial port number on which this signal applies
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ogsgnlEventPortLabel 1.3.6.1.4.1.25049.2.11.10.1.1.1.13
The label for the serial port where the signal applies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogsgnlEventOccurred 1002
The alert sent when a signal change occurs
TRAP-TYPE    

ogPatternMibObjects 1.3.6.1.4.1.25049.2.12.10
OBJECT IDENTIFIER    

ogpatnEvent 1.3.6.1.4.1.25049.2.12.10.1
OBJECT IDENTIFIER    

ogpatnEventTable 1.3.6.1.4.1.25049.2.12.10.1.1
OBJECT IDENTIFIER    

ogpatnEventEntry 1.3.6.1.4.1.25049.2.12.10.1.1.1
OBJECT IDENTIFIER    

ogpatnEventDescription 1.3.6.1.4.1.25049.2.12.10.1.1.1.10
A description of the matches purpose
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogpatnEventText 1.3.6.1.4.1.25049.2.12.10.1.1.1.11
The full text which matched the pattern
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogpatnEventPortNumber 1.3.6.1.4.1.25049.2.12.10.1.1.1.12
Serial port number on which the pattern matched
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ogpatnEventPortLabel 1.3.6.1.4.1.25049.2.12.10.1.1.1.13
The label for the serial port where pattern match occurred
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogpatnEventOccurred 1003
The alert sent when a pre-defined pattern was matched text in a consoles serial character stream
TRAP-TYPE    

ogSensorMibObjects 1.3.6.1.4.1.25049.2.13.10
OBJECT IDENTIFIER    

ogsensStatus 1.3.6.1.4.1.25049.2.13.10.1
OBJECT IDENTIFIER    

ogsensStatusTable 1.3.6.1.4.1.25049.2.13.10.1.1
OBJECT IDENTIFIER    

ogsensStatusEntry 1.3.6.1.4.1.25049.2.13.10.1.1.1
OBJECT IDENTIFIER    

ogsensStatusName 1.3.6.1.4.1.25049.2.13.10.1.1.1.10
The name of the device pertaining to the status event
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogsensStatusDevType 1.3.6.1.4.1.25049.2.13.10.1.1.1.11
The type of device pertaining to the status event
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogsensStatusType 1.3.6.1.4.1.25049.2.13.10.1.1.1.12
The type of sensor pertaining to the status event
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogsensStatusValue 1.3.6.1.4.1.25049.2.13.10.1.1.1.13
The value of the sensor pertaining to the status event
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ogsensStatusOccurred 1004
The trap sent when a sensor event occurs
TRAP-TYPE    

ogHostMibObjects 1.3.6.1.4.1.25049.2.14.10
OBJECT IDENTIFIER    

oghostEvent 1.3.6.1.4.1.25049.2.14.10.1
OBJECT IDENTIFIER    

oghostEventTable 1.3.6.1.4.1.25049.2.14.10.1.1
OBJECT IDENTIFIER    

oghostEventEntry 1.3.6.1.4.1.25049.2.14.10.1.1.1
OBJECT IDENTIFIER    

oghostEventUsername 1.3.6.1.4.1.25049.2.14.10.1.1.1.10
The user pertaining to the connection event
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

oghostEventType 1.3.6.1.4.1.25049.2.14.10.1.1.1.11
The type of connection event
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

oghostEventAddress 1.3.6.1.4.1.25049.2.14.10.1.1.1.12
The address of the host to which this connection applies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

oghostEventDescription 1.3.6.1.4.1.25049.2.14.10.1.1.1.13
The description of the host to which this connection applies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

oghostEventProtocol 1.3.6.1.4.1.25049.2.14.10.1.1.1.14
The internet protocl to which this connection applies.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

oghostEventPort 1.3.6.1.4.1.25049.2.14.10.1.1.1.15
The applicable port number of the host.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oghostEventOccurred 2001
The alert sent when a user connection event occurs
TRAP-TYPE    

ogFailoverMibObjects 1.3.6.1.4.1.25049.2.15.10
OBJECT IDENTIFIER    

ogfovrEvent 1.3.6.1.4.1.25049.2.15.10.1
OBJECT IDENTIFIER    

ogfovrEventTable 1.3.6.1.4.1.25049.2.15.10.1.1
OBJECT IDENTIFIER    

ogfovrEventEntry 1.3.6.1.4.1.25049.2.15.10.1.1.1
OBJECT IDENTIFIER    

ogfovrEventPrimary 1.3.6.1.4.1.25049.2.15.10.1.1.1.10
The name of the network interface which failed
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogfovrEventSecondary 1.3.6.1.4.1.25049.2.15.10.1.1.1.11
The name of the network interface which was connected instead
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogfovrEventOccurred 2002
The alert sent when a network failover event occurs
TRAP-TYPE    

ogNetUpsMibObjects 1.3.6.1.4.1.25049.2.16.10
OBJECT IDENTIFIER    

ognupsEvent 1.3.6.1.4.1.25049.2.16.10.1
OBJECT IDENTIFIER    

ognupsEventTable 1.3.6.1.4.1.25049.2.16.10.1.1
OBJECT IDENTIFIER    

ognupsEventEntry 1.3.6.1.4.1.25049.2.16.10.1.1.1
OBJECT IDENTIFIER    

ognupsEventName 1.3.6.1.4.1.25049.2.16.10.1.1.1.10
The name of the UPS pertaining to the status event
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ognupsEventType 1.3.6.1.4.1.25049.2.16.10.1.1.1.11
The type of status event
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ognupsEventOccurred 2003
The alert sent when a UPS status event occurs
TRAP-TYPE    

ogDataMibObjects 1.3.6.1.4.1.25049.2.17.10
OBJECT IDENTIFIER    

ogdataEvent 1.3.6.1.4.1.25049.2.17.10.1
OBJECT IDENTIFIER    

ogdataEventTable 1.3.6.1.4.1.25049.2.17.10.1.1
OBJECT IDENTIFIER    

ogdataEventEntry 1.3.6.1.4.1.25049.2.17.10.1.1.1
OBJECT IDENTIFIER    

ogdataEventBytes 1.3.6.1.4.1.25049.2.17.10.1.1.1.10
The amount of bytes which triggers this usage alert
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ogdataEventSeconds 1.3.6.1.4.1.25049.2.17.10.1.1.1.11
The time in seconds over which bytes are measured
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ogdataEventDevice 1.3.6.1.4.1.25049.2.17.10.1.1.1.12
The ID for the interface thos pertains to
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

ogdataEventState 1.3.6.1.4.1.25049.2.17.10.1.1.1.13
Whether data usage alert is on (1) or off (0)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ogdataEventOccurred 2004
The trap sent when a data usage alert occurs
TRAP-TYPE