OGTRAP-MIB
File:
OGTRAP-MIB.mib (11103 bytes)
Imported modules
Imported symbols
Defined Values
opengear |
1.3.6.1.4.1.25049 |
OBJECT IDENTIFIER |
|
|
|
ogHostMib |
1.3.6.1.4.1.25049.2.14 |
OBJECT IDENTIFIER |
|
|
|
ogDataMib |
1.3.6.1.4.1.25049.2.17 |
OBJECT IDENTIFIER |
|
|
|
ogconnEvent |
1.3.6.1.4.1.25049.2.10.10.1 |
OBJECT IDENTIFIER |
|
|
|
ogconnEventEntry |
1.3.6.1.4.1.25049.2.10.10.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
ogconnEventUsername |
1.3.6.1.4.1.25049.2.10.10.1.1.1.10 |
The user pertaining to the connection event |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogconnEventType |
1.3.6.1.4.1.25049.2.10.10.1.1.1.11 |
The type of connection event |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogconnEventPortNumber |
1.3.6.1.4.1.25049.2.10.10.1.1.1.12 |
Serial port number on which this connection applies |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ogconnEventPortLabel |
1.3.6.1.4.1.25049.2.10.10.1.1.1.13 |
The label for the serial port where the connection
occurred. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogsgnlEvent |
1.3.6.1.4.1.25049.2.11.10.1 |
OBJECT IDENTIFIER |
|
|
|
ogsgnlEventEntry |
1.3.6.1.4.1.25049.2.11.10.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
ogsgnlEventType |
1.3.6.1.4.1.25049.2.11.10.1.1.1.10 |
The particular signal which changed |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogsgnlEventState |
1.3.6.1.4.1.25049.2.11.10.1.1.1.11 |
The current signal state |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogsgnlEventPortNumber |
1.3.6.1.4.1.25049.2.11.10.1.1.1.12 |
Serial port number on which this signal applies |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ogsgnlEventPortLabel |
1.3.6.1.4.1.25049.2.11.10.1.1.1.13 |
The label for the serial port where the signal applies. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogpatnEvent |
1.3.6.1.4.1.25049.2.12.10.1 |
OBJECT IDENTIFIER |
|
|
|
ogpatnEventEntry |
1.3.6.1.4.1.25049.2.12.10.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
ogpatnEventDescription |
1.3.6.1.4.1.25049.2.12.10.1.1.1.10 |
A description of the matches purpose |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogpatnEventText |
1.3.6.1.4.1.25049.2.12.10.1.1.1.11 |
The full text which matched the pattern |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogpatnEventPortNumber |
1.3.6.1.4.1.25049.2.12.10.1.1.1.12 |
Serial port number on which the pattern matched |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ogpatnEventPortLabel |
1.3.6.1.4.1.25049.2.12.10.1.1.1.13 |
The label for the serial port where pattern match
occurred |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogpatnEventOccurred |
1003 |
The alert sent when a pre-defined pattern was
matched text in a consoles serial character stream |
TRAP-TYPE |
|
|
|
ogsensStatusEntry |
1.3.6.1.4.1.25049.2.13.10.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
ogsensStatusName |
1.3.6.1.4.1.25049.2.13.10.1.1.1.10 |
The name of the device pertaining to the status event |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogsensStatusDevType |
1.3.6.1.4.1.25049.2.13.10.1.1.1.11 |
The type of device pertaining to the status event |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogsensStatusType |
1.3.6.1.4.1.25049.2.13.10.1.1.1.12 |
The type of sensor pertaining to the status event |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogsensStatusValue |
1.3.6.1.4.1.25049.2.13.10.1.1.1.13 |
The value of the sensor pertaining to the status event |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
oghostEvent |
1.3.6.1.4.1.25049.2.14.10.1 |
OBJECT IDENTIFIER |
|
|
|
oghostEventEntry |
1.3.6.1.4.1.25049.2.14.10.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
oghostEventUsername |
1.3.6.1.4.1.25049.2.14.10.1.1.1.10 |
The user pertaining to the connection event |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
oghostEventType |
1.3.6.1.4.1.25049.2.14.10.1.1.1.11 |
The type of connection event |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
oghostEventAddress |
1.3.6.1.4.1.25049.2.14.10.1.1.1.12 |
The address of the host to which this connection applies. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
oghostEventDescription |
1.3.6.1.4.1.25049.2.14.10.1.1.1.13 |
The description of the host to which this connection applies. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
oghostEventProtocol |
1.3.6.1.4.1.25049.2.14.10.1.1.1.14 |
The internet protocl to which this connection applies. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
oghostEventPort |
1.3.6.1.4.1.25049.2.14.10.1.1.1.15 |
The applicable port number of the host. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ogfovrEvent |
1.3.6.1.4.1.25049.2.15.10.1 |
OBJECT IDENTIFIER |
|
|
|
ogfovrEventEntry |
1.3.6.1.4.1.25049.2.15.10.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
ogfovrEventPrimary |
1.3.6.1.4.1.25049.2.15.10.1.1.1.10 |
The name of the network interface which failed |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogfovrEventSecondary |
1.3.6.1.4.1.25049.2.15.10.1.1.1.11 |
The name of the network interface which was connected
instead |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ognupsEvent |
1.3.6.1.4.1.25049.2.16.10.1 |
OBJECT IDENTIFIER |
|
|
|
ognupsEventEntry |
1.3.6.1.4.1.25049.2.16.10.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
ognupsEventName |
1.3.6.1.4.1.25049.2.16.10.1.1.1.10 |
The name of the UPS pertaining to the status event |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ognupsEventType |
1.3.6.1.4.1.25049.2.16.10.1.1.1.11 |
The type of status event |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogdataEvent |
1.3.6.1.4.1.25049.2.17.10.1 |
OBJECT IDENTIFIER |
|
|
|
ogdataEventEntry |
1.3.6.1.4.1.25049.2.17.10.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
ogdataEventBytes |
1.3.6.1.4.1.25049.2.17.10.1.1.1.10 |
The amount of bytes which triggers this usage alert |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ogdataEventSeconds |
1.3.6.1.4.1.25049.2.17.10.1.1.1.11 |
The time in seconds over which bytes are measured |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ogdataEventDevice |
1.3.6.1.4.1.25049.2.17.10.1.1.1.12 |
The ID for the interface thos pertains to |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ogdataEventState |
1.3.6.1.4.1.25049.2.17.10.1.1.1.13 |
Whether data usage alert is on (1) or off (0) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|