OLD-CISCO-ENV-MIB
File:
OLD-CISCO-ENV-MIB.mib (13718 bytes)
Imported modules
Imported symbols
Defined Values
lenv |
2.1 |
OBJECT IDENTIFIER |
|
|
|
envPresent |
2.1.77 |
Is there an environmental monitor card in
this box?, 0 - No, 1-AGS card present, wrong
firmware, 2-AGS CARD present, firmware ok,
3-7000 support |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt1Descr |
2.1.78 |
Description of the test point 1. Typically
ambient air or the temperature of air
entering the router |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
envTestPt1Measure |
2.1.79 |
Current value of test point 1. Typically a
temperature in centigrade. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt2Descr |
2.1.80 |
Description of the test point 2. Typically
airflow or the temperature of air leaving the
router |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
envTestPt2Measure |
2.1.81 |
Current value of test point 2. Typically a
temperature in centigrade. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt3Measure |
2.1.83 |
Current value of test point 3. Typically the
value in millivolts of the +5v supply |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt4Measure |
2.1.85 |
Current value of test point 4. Typically the
value in millivolts of the +12v supply |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt5Measure |
2.1.87 |
Current value of test point 5. Typically the
value in millivolts of the -12v supply |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt6Measure |
2.1.89 |
Current value of test point 6. Typically the
value in millivolts of the -5v supply |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt1MarginVal |
2.1.90 |
Value at which the router will shutdown.
Typically the ambient air temperature that
will shut the router down. (e.g. 43) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt2MarginVal |
2.1.91 |
Value at which the router will shutdown.
Typically the airflow air temperature that
will shut the router down. (e.g. 58) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt3MarginPercent |
2.1.92 |
+/- Percentage that will shut the router
down, (e.g. 10%) typically +5 volt |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt4MarginPercent |
2.1.93 |
+/- Percentage that will shut the router
down, (e.g. 15%) typically +12 volt |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt5MarginPercent |
2.1.94 |
+/- Percentage that will shut the router
down, (e.g. 15%) typically -12 volt |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt6MarginPercent |
2.1.95 |
+/- Percentage that will shut the router
down, (e.g. 10%) typically -5 volt |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt1last |
2.1.96 |
Value of TestPt1 when last shutdown
occurred. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt2last |
2.1.97 |
Value of TestPt2 when last shutdown
occurred. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt3last |
2.1.98 |
Value of TestPt3 when last shutdown
occurred. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt4last |
2.1.99 |
Value of TestPt4 when last shutdown
occurred. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt5last |
2.1.100 |
Value of TestPt5 when last shutdown
occurred. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt6last |
2.1.101 |
Value of TestPt6 when last shutdown
occurred. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
envTestPt1warn |
2.1.102 |
Is this test point at a warning level? |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
warning(1), noWarning(2) |
|
envTestPt2warn |
2.1.103 |
Is this test point at a warning level? |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
warning(1), noWarning(2) |
|
envTestPt3warn |
2.1.104 |
Is this test point at a warning level? |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
warning(1), noWarning(2) |
|
envTestPt4warn |
2.1.105 |
Is this test point at a warning level? |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
warning(1), noWarning(2) |
|
envTestPt5warn |
2.1.106 |
Is this test point at a warning level? |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
warning(1), noWarning(2) |
|
envTestPt6warn |
2.1.107 |
Is this test point at a warning level? |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
warning(1), noWarning(2) |
|
envType |
2.1.110 |
The type of environmental card |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|