OLD-CISCO-ENV-MIB

File: OLD-CISCO-ENV-MIB.mib (13718 bytes)

Imported modules

RFC-1212 RFC1213-MIB CISCO-SMI

Imported symbols

OBJECT-TYPE DisplayString local

Defined Values

lenv 2.1
OBJECT IDENTIFIER    

envPresent 2.1.77
Is there an environmental monitor card in this box?, 0 - No, 1-AGS card present, wrong firmware, 2-AGS CARD present, firmware ok, 3-7000 support
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt1Descr 2.1.78
Description of the test point 1. Typically ambient air or the temperature of air entering the router
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

envTestPt1Measure 2.1.79
Current value of test point 1. Typically a temperature in centigrade.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt2Descr 2.1.80
Description of the test point 2. Typically airflow or the temperature of air leaving the router
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

envTestPt2Measure 2.1.81
Current value of test point 2. Typically a temperature in centigrade.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt3Descr 2.1.82
Description of the test point 3. Typically +5 volt
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

envTestPt3Measure 2.1.83
Current value of test point 3. Typically the value in millivolts of the +5v supply
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt4Descr 2.1.84
Description of the test point 4. Typically +12 volt
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

envTestPt4Measure 2.1.85
Current value of test point 4. Typically the value in millivolts of the +12v supply
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt5Descr 2.1.86
Description of the test point 5. Typically -12 volt
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

envTestPt5Measure 2.1.87
Current value of test point 5. Typically the value in millivolts of the -12v supply
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt6Descr 2.1.88
Description of the test point 6. Typically -5 volt
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

envTestPt6Measure 2.1.89
Current value of test point 6. Typically the value in millivolts of the -5v supply
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt1MarginVal 2.1.90
Value at which the router will shutdown. Typically the ambient air temperature that will shut the router down. (e.g. 43)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt2MarginVal 2.1.91
Value at which the router will shutdown. Typically the airflow air temperature that will shut the router down. (e.g. 58)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt3MarginPercent 2.1.92
+/- Percentage that will shut the router down, (e.g. 10%) typically +5 volt
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt4MarginPercent 2.1.93
+/- Percentage that will shut the router down, (e.g. 15%) typically +12 volt
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt5MarginPercent 2.1.94
+/- Percentage that will shut the router down, (e.g. 15%) typically -12 volt
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt6MarginPercent 2.1.95
+/- Percentage that will shut the router down, (e.g. 10%) typically -5 volt
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt1last 2.1.96
Value of TestPt1 when last shutdown occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt2last 2.1.97
Value of TestPt2 when last shutdown occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt3last 2.1.98
Value of TestPt3 when last shutdown occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt4last 2.1.99
Value of TestPt4 when last shutdown occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt5last 2.1.100
Value of TestPt5 when last shutdown occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt6last 2.1.101
Value of TestPt6 when last shutdown occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

envTestPt1warn 2.1.102
Is this test point at a warning level?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER warning(1), noWarning(2)  

envTestPt2warn 2.1.103
Is this test point at a warning level?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER warning(1), noWarning(2)  

envTestPt3warn 2.1.104
Is this test point at a warning level?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER warning(1), noWarning(2)  

envTestPt4warn 2.1.105
Is this test point at a warning level?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER warning(1), noWarning(2)  

envTestPt5warn 2.1.106
Is this test point at a warning level?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER warning(1), noWarning(2)  

envTestPt6warn 2.1.107
Is this test point at a warning level?
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER warning(1), noWarning(2)  

envFirmVersion 2.1.108
Description of Environmental Card firmware
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

envTechnicianID 2.1.109
Technician ID
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

envType 2.1.110
The type of environmental card
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

envBurnDate 2.1.111
The calibration / burn in date
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

envSerialNumber 2.1.112
Serial Number of environmental monitor card
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString