OMNI-gx2Em870-MIB

File: OMNI-gx2Em870-MIB.mib (77347 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2Em870 trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2Em870AnalogEntry  
SEQUENCE    
  gx2Em870AnalogTableIndex INTEGER
  em870labelOpticalPower DisplayString Size(0..80)
  em870uomOpticalPower DisplayString Size(0..80)
  em870majorHighOpticalPower Float
  em870majorLowOpticalPower Float
  em870minorHighOpticalPower Float
  em870minorLowOpticalPower Float
  em870currentValueOpticalPower Float
  em870stateFlagOpticalPower INTEGER
  em870minValueOpticalPower Float
  em870maxValueOpticalPower Float
  em870alarmStateOpticalPower INTEGER
  em870labelOmiOffset DisplayString Size(0..80)
  em870uomOmiOffset DisplayString Size(0..80)
  em870majorHighOmiOffset Float
  em870majorLowOmiOffset Float
  em870minorHighOmiOffset Float
  em870minorLowOmiOffset Float
  em870currentValueOmiOffset Float
  em870stateFlagOmiOffset INTEGER
  em870minValueOmiOffset Float
  em870maxValueOmiOffset Float
  em870alarmStateOmiOffset INTEGER
  em870labelDFBPower DisplayString Size(0..80)
  em870uomDFBPower DisplayString Size(0..80)
  em870majorHighDFBPower Float
  em870majorLowDFBPower Float
  em870minorHighDFBPower Float
  em870minorLowDFBPower Float
  em870currentValueDFBPower Float
  em870stateFlagDFBPower INTEGER
  em870minValueDFBPower Float
  em870maxValueDFBPower Float
  em870alarmStateDFBPower INTEGER
  em870labelLaserBias DisplayString Size(0..80)
  em870uomLaserBias DisplayString Size(0..80)
  em870majorHighLaserBias Float
  em870majorLowLaserBias Float
  em870minorHighLaserBias Float
  em870minorLowLaserBias Float
  em870currentValueLaserBias Float
  em870stateFlagLaserBias INTEGER
  em870minValueLaserBias Float
  em870maxValueLaserBias Float
  em870alarmStateLaserBias INTEGER
  em870labelCoolerCurrent DisplayString Size(0..80)
  em870uomCoolerCurrent DisplayString Size(0..80)
  em870majorHighCoolerCurrent Float
  em870majorLowCoolerCurrent Float
  em870minorHighCoolerCurrent Float
  em870minorLowCoolerCurrent Float
  em870currentValueCoolerCurrent Float
  em870stateFlagCoolerCurrent INTEGER
  em870minValueCoolerCurrent Float
  em870maxValueCoolerCurrent Float
  em870alarmStateCoolerCurrent INTEGER
  em870labelLaserTemp DisplayString Size(0..80)
  em870uomLaserTemp DisplayString Size(0..80)
  em870majorHighLaserTemp Float
  em870majorLowLaserTemp Float
  em870minorHighLaserTemp Float
  em870minorLowLaserTemp Float
  em870currentValueLaserTemp Float
  em870stateFlagLaserTemp INTEGER
  em870minValueLaserTemp Float
  em870maxValueLaserTemp Float
  em870alarmStateLaserTemp INTEGER
  em870labelModTemp DisplayString Size(0..80)
  em870uomModTemp DisplayString Size(0..80)
  em870majorHighModTemp Float
  em870majorLowModTemp Float
  em870minorHighModTemp Float
  em870minorLowModTemp Float
  em870currentValueModTemp Float
  em870stateFlagModTemp INTEGER
  em870minValueModTemp Float
  em870maxValueModTemp Float
  em870alarmStateModTemp INTEGER
  em870labelFanCurrent DisplayString Size(0..80)
  em870uomFanCurrent DisplayString Size(0..80)
  em870majorHighFanCurrent Float
  em870majorLowFanCurrent Float
  em870minorHighFanCurrent Float
  em870minorLowFanCurrent Float
  em870currentValueFanCurrent Float
  em870stateFlagFanCurrent INTEGER
  em870minValueFanCurrent Float
  em870maxValueFanCurrent Float
  em870alarmStateFanCurrent INTEGER
  em870label12Volt DisplayString Size(0..80)
  em870uom12Volt DisplayString Size(0..80)
  em870majorHigh12Volt Float
  em870majorLow12Volt Float
  em870minorHigh12Volt Float
  em870minorLow12Volt Float
  em870currentValue12Volt Float
  em870stateFlag12Volt INTEGER
  em870minValue12Volt Float
  em870maxValue12Volt Float
  em870alarmState12Volt INTEGER

Gx2Em870DigitalEntry  
SEQUENCE    
  gx2Em870DigitalTableIndex INTEGER
  em870labelOpticalAlarmSetpoint DisplayString Size(0..80)
  em870valueOpticalAlarmSetpoint INTEGER
  em870enumOpticalAlarmSetpoint DisplayString Size(0..80)
  em870stateFlagOpticalAlarmSetpoint INTEGER

Gx2Em870StatusEntry  
SEQUENCE    
  gx2Em870StatusTableIndex INTEGER
  em870labelBoot DisplayString Size(0..80)
  em870valueBoot INTEGER
  em870stateflagBoot INTEGER
  em870labelFlash DisplayString Size(0..80)
  em870valueFlash INTEGER
  em870stateflagFlash INTEGER
  em870labelFactoryDataCRC DisplayString Size(0..80)
  em870valueFactoryDataCRC INTEGER
  em870stateflagFactoryDataCRC INTEGER
  em870labelAlarmDataCrc DisplayString Size(0..80)
  em870valueAlarmDataCrc INTEGER
  em870stateflagAlarmDataCrc INTEGER
  em870labelCsoStatus DisplayString Size(0..80)
  em870valueCsoStatus INTEGER
  em870stateflagCsoStatus INTEGER

Gx2Em870FactoryEntry  
SEQUENCE    
  gx2Em870FactoryTableIndex INTEGER
  em870bootControlByte INTEGER
  em870bootStatusByte INTEGER
  em870bank1CRC INTEGER
  em870bank2CRC INTEGER
  em870prgEEPROMByte INTEGER
  em870factoryCRC INTEGER
  em870calculateCRC INTEGER
  em870hourMeter INTEGER
  em870flashPrgCntA INTEGER
  em870flashPrgCntB INTEGER
  em870flashBankARev DisplayString Size(0..80)
  em870flashBankBRev DisplayString Size(0..80)

Gx2Em870HoldTimeEntry  
SEQUENCE    
  gx2Em870HoldTimeTableIndex INTEGER
  gx2Em870HoldTimeSpecIndex INTEGER
  gx2Em870HoldTimeData INTEGER

Defined Values

gx2Em870Descriptor 1.3.6.1.4.1.1166.6.1.2.12.1
OBJECT IDENTIFIER    

gx2Em870AnalogTable 1.3.6.1.4.1.1166.6.1.2.12.2
This table contains gx2Em870 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Em870AnalogEntry

gx2Em870AnalogEntry 1.3.6.1.4.1.1166.6.1.2.12.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Em870AnalogEntry  

gx2Em870StatusTable 1.3.6.1.4.1.1166.6.1.2.12.4
This table contains gx2Em870 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Em870StatusEntry

gx2Em870StatusEntry 1.3.6.1.4.1.1166.6.1.2.12.4.2
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Em870StatusEntry  

gx2Em870FactoryTable 1.3.6.1.4.1.1166.6.1.2.12.5
This table contains gx2Em870 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Em870FactoryEntry

gx2Em870FactoryEntry 1.3.6.1.4.1.1166.6.1.2.12.5.3
This list contains Factory parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Em870FactoryEntry  

gx2Em870DigitalTable 1.3.6.1.4.1.1166.6.1.2.12.3
This table contains gx2Em870 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Em870DigitalEntry

gx2Em870DigitalEntry 1.3.6.1.4.1.1166.6.1.2.12.3.4
This list contains the digital parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Em870DigitalEntry  

gx2Em870HoldTimeTable 1.3.6.1.4.1.1166.6.1.2.12.6
This table contains gx2EM870 specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Em870HoldTimeEntry

gx2Em870HoldTimeEntry 1.3.6.1.4.1.1166.6.1.2.12.6.5
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Em870HoldTimeEntry  

gx2Em870AnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.12.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

em870labelOpticalPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.2
The value of this object provides the label of the Optical Output Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870uomOpticalPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.3
The value of this object provides the Unit of Measure of the Optical Output Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870majorHighOpticalPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.4
The value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870majorLowOpticalPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.5
The value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorHighOpticalPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.6
The value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorLowOpticalPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.7
The value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870currentValueOpticalPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.8
The value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870stateFlagOpticalPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.9
The value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870minValueOpticalPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.10
The value of this object provides the minimum value the Optical Output Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870maxValueOpticalPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.11
The value of this object provides the maximum value the Optical Output Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870alarmStateOpticalPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.12
The value of this object provides the curent alarm state of the Optical Output Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

em870labelOmiOffset 1.3.6.1.4.1.1166.6.1.2.12.2.1.13
The value of this object provides the label of the RF Input Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870uomOmiOffset 1.3.6.1.4.1.1166.6.1.2.12.2.1.14
The value of this object provides the Unit of Measure of the RF Input Power Analog parameter..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870majorHighOmiOffset 1.3.6.1.4.1.1166.6.1.2.12.2.1.15
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870majorLowOmiOffset 1.3.6.1.4.1.1166.6.1.2.12.2.1.16
The value of this object provides the Major Low alarm value of the RF Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorHighOmiOffset 1.3.6.1.4.1.1166.6.1.2.12.2.1.17
The value of this object provides the Minor High alarm value of the RF Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorLowOmiOffset 1.3.6.1.4.1.1166.6.1.2.12.2.1.18
The value of this object provides the Minor Low alarm value of the RF Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870currentValueOmiOffset 1.3.6.1.4.1.1166.6.1.2.12.2.1.19
The value of this object provides the Current value of the RF Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. +99 dB or -99 dB will be reported for this value when outside the min/max operating range.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870stateFlagOmiOffset 1.3.6.1.4.1.1166.6.1.2.12.2.1.20
The value of this object provides the state of the RF Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870minValueOmiOffset 1.3.6.1.4.1.1166.6.1.2.12.2.1.21
The value of this object provides the minimum value the RF Input Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870maxValueOmiOffset 1.3.6.1.4.1.1166.6.1.2.12.2.1.22
The value of this object provides the maximum value the RF Input Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870alarmStateOmiOffset 1.3.6.1.4.1.1166.6.1.2.12.2.1.23
The value of this object provides the curent alarm state of the RF Input Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

em870labelDFBPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.24
The value of this object provides the label of the DFB Output Power Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870uomDFBPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.25
The value of this object provides the Unit of Measure of the DFB Output Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870majorHighDFBPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.26
The value of this object provides the Major High alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870majorLowDFBPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.27
The value of this object provides the Major Low alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorHighDFBPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.28
The value of this object provides the Minor High alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorLowDFBPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.29
The value of this object provides the Minor Low alarm value of the DFB Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870currentValueDFBPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.30
The value of this object provides the Current value of the DFB Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870stateFlagDFBPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.31
The value of this object provides the state of the DFB Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870minValueDFBPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.32
The value of this object provides the minimum value the DFB Output Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870maxValueDFBPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.33
The value of this object provides the maximum value the DFB Output Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870alarmStateDFBPower 1.3.6.1.4.1.1166.6.1.2.12.2.1.34
The value of this object provides the curent alarm state of the DFB Output Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

em870labelLaserBias 1.3.6.1.4.1.1166.6.1.2.12.2.1.35
The value of this object provides the label of the Laser Bias Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870uomLaserBias 1.3.6.1.4.1.1166.6.1.2.12.2.1.36
The value of this object provides the Unit of Measure of the Laser Bias Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870majorHighLaserBias 1.3.6.1.4.1.1166.6.1.2.12.2.1.37
The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870majorLowLaserBias 1.3.6.1.4.1.1166.6.1.2.12.2.1.38
The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorHighLaserBias 1.3.6.1.4.1.1166.6.1.2.12.2.1.39
The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorLowLaserBias 1.3.6.1.4.1.1166.6.1.2.12.2.1.40
The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870currentValueLaserBias 1.3.6.1.4.1.1166.6.1.2.12.2.1.41
The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870stateFlagLaserBias 1.3.6.1.4.1.1166.6.1.2.12.2.1.42
The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870minValueLaserBias 1.3.6.1.4.1.1166.6.1.2.12.2.1.43
The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870maxValueLaserBias 1.3.6.1.4.1.1166.6.1.2.12.2.1.44
The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870alarmStateLaserBias 1.3.6.1.4.1.1166.6.1.2.12.2.1.45
The value of this object provides the curent alarm state of the Laser Bias Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

em870labelCoolerCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.46
The value of this object provides the label of the Cooler Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870uomCoolerCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.47
The value of this object provides the Unit of Measure of the Cooler Current Analog parameter..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870majorHighCoolerCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.48
The value of this object provides the Major High alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870majorLowCoolerCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.49
The value of this object provides the Major Low alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorHighCoolerCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.50
The value of this object provides the Minor High alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorLowCoolerCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.51
The value of this object provides the Minor Low alarm value of the Cooler Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870currentValueCoolerCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.52
The value of this object provides the Current value of the Cooler Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870stateFlagCoolerCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.53
The value of this object provides the state of the Cooler Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870minValueCoolerCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.54
The value of this object provides the minimum value the Cooler Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870maxValueCoolerCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.55
The value of this object provides the maximum value the Cooler Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870alarmStateCoolerCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.56
The value of this object provides the curent alarm state of the Cooler Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

em870labelLaserTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.57
The value of this object provides the label of the Laser Temp Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870uomLaserTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.58
The value of this object provides the Unit of Measure of the Laser Temp Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870majorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.59
The value of this object provides the Major High alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870majorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.60
The value of this object provides the Major Low alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.61
The value of this object provides the Minor High alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.62
The value of this object provides the Minor Low alarm value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870currentValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.63
The value of this object provides the Current value of the Laser Temp Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870stateFlagLaserTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.64
The value of this object provides the state of the Laser Temp Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870minValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.65
The value of this object provides the minimum value the Laser TempAnalog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870maxValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.66
The value of this object provides the maximum value the Laser Temp Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870alarmStateLaserTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.67
The value of this object provides the curent alarm state of the Laser Temp Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

em870labelModTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.68
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870uomModTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.69
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870majorHighModTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.70
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870majorLowModTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.71
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorHighModTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.72
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorLowModTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.73
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870currentValueModTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.74
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870stateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.75
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870minValueModTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.76
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870maxValueModTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.77
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870alarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.12.2.1.78
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

em870labelFanCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.79
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870uomFanCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.80
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870majorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.81
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870majorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.82
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.83
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.84
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870currentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.85
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870stateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.86
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870minValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.87
The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870maxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.88
The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870alarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.12.2.1.89
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

em870label12Volt 1.3.6.1.4.1.1166.6.1.2.12.2.1.90
The value of this object provides the label of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870uom12Volt 1.3.6.1.4.1.1166.6.1.2.12.2.1.91
The value of this object provides the Unit of Measure of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870majorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.12.2.1.92
The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870majorLow12Volt 1.3.6.1.4.1.1166.6.1.2.12.2.1.93
The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.12.2.1.94
The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870minorLow12Volt 1.3.6.1.4.1.1166.6.1.2.12.2.1.95
The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870currentValue12Volt 1.3.6.1.4.1.1166.6.1.2.12.2.1.96
The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870stateFlag12Volt 1.3.6.1.4.1.1166.6.1.2.12.2.1.97
The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870minValue12Volt 1.3.6.1.4.1.1166.6.1.2.12.2.1.98
The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870maxValue12Volt 1.3.6.1.4.1.1166.6.1.2.12.2.1.99
The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

em870alarmState12Volt 1.3.6.1.4.1.1166.6.1.2.12.2.1.100
The value of this object provides the curent alarm state of the 12v Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2Em870DigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.12.3.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

em870labelOpticalAlarmSetpoint 1.3.6.1.4.1.1166.6.1.2.12.3.4.2
The value of this object provides the label of the EM870's Optical Alarm setpoint Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870enumOpticalAlarmSetpoint 1.3.6.1.4.1.1166.6.1.2.12.3.4.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870valueOpticalAlarmSetpoint 1.3.6.1.4.1.1166.6.1.2.12.3.4.4
The value of this object is the current value of the parameter. Note that reset setting returns the parameter to the off setting
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

em870stateFlagOpticalAlarmSetpoint 1.3.6.1.4.1.1166.6.1.2.12.3.4.5
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2Em870StatusTableIndex 1.3.6.1.4.1.1166.6.1.2.12.4.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

em870labelBoot 1.3.6.1.4.1.1166.6.1.2.12.4.2.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870valueBoot 1.3.6.1.4.1.1166.6.1.2.12.4.2.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

em870stateflagBoot 1.3.6.1.4.1.1166.6.1.2.12.4.2.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870labelFlash 1.3.6.1.4.1.1166.6.1.2.12.4.2.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870valueFlash 1.3.6.1.4.1.1166.6.1.2.12.4.2.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

em870stateflagFlash 1.3.6.1.4.1.1166.6.1.2.12.4.2.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870labelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.12.4.2.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870valueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.12.4.2.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

em870stateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.12.4.2.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870labelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.12.4.2.11
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870valueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.12.4.2.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

em870stateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.12.4.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

em870labelCsoStatus 1.3.6.1.4.1.1166.6.1.2.12.4.2.14
The value of this object provides the label of the CSO Status parameter. This parameter is always hidden
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870valueCsoStatus 1.3.6.1.4.1.1166.6.1.2.12.4.2.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

em870stateflagCsoStatus 1.3.6.1.4.1.1166.6.1.2.12.4.2.16
The value of this object provides the state of the the CSO Status parameter. This parameter is always hidden (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2Em870FactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.12.5.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

em870bootControlByte 1.3.6.1.4.1.1166.6.1.2.12.5.3.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

em870bootStatusByte 1.3.6.1.4.1.1166.6.1.2.12.5.3.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

em870bank1CRC 1.3.6.1.4.1.1166.6.1.2.12.5.3.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

em870bank2CRC 1.3.6.1.4.1.1166.6.1.2.12.5.3.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

em870prgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.12.5.3.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

em870factoryCRC 1.3.6.1.4.1.1166.6.1.2.12.5.3.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

em870calculateCRC 1.3.6.1.4.1.1166.6.1.2.12.5.3.8
This object indicates which of the Emnums will have the CRC calculated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), na(2), alarm(3)  

em870hourMeter 1.3.6.1.4.1.1166.6.1.2.12.5.3.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

em870flashPrgCntA 1.3.6.1.4.1.1166.6.1.2.12.5.3.10
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

em870flashPrgCntB 1.3.6.1.4.1.1166.6.1.2.12.5.3.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

em870flashBankARev 1.3.6.1.4.1.1166.6.1.2.12.5.3.12
This object provides the revision of flash bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

em870flashBankBRev 1.3.6.1.4.1.1166.6.1.2.12.5.3.13
This object provides the revision of flash bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gx2Em870HoldTimeTableIndex 1.3.6.1.4.1.1166.6.1.2.12.6.5.1
The value of this object is the index of the data object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2Em870HoldTimeSpecIndex 1.3.6.1.4.1.1166.6.1.2.12.6.5.2
The value of this object identifies the index of the alarm object to be modified.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2Em870HoldTimeData 1.3.6.1.4.1.1166.6.1.2.12.6.5.3
The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

trapEM870ConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapEM870ConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapEM870FanCurrentAlarm 3
This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEM87012vAlarm 4
This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEM870ModuleTempAlarm 5
This trap is issued when the Module Temperature goes out of range.
TRAP-TYPE    

trapEM870OmiOffsetAlarm 6
This trap is issued when the Laser Modules OMI level parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEM870OpticalOutputPowerAlarm 7
This trap is issued when the Laser Modules Optical Output power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapEM870FlashAlarm 8
This trap is issued when the Laser Modules detects an error during Flash memory operations.
TRAP-TYPE    

trapEM870BankBootAlarm 9
This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapEM870AlarmDataCRCAlarm 10
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapEM870FactoryDataCRCAlarm 11
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE