Float  
Counter    

Gx2lmeAnalogEntry  
SEQUENCE    
  gx2lmeAnalogTableIndex INTEGER
  lmelabelOffsetNomMonitor DisplayString Size(0..80)
  lmeuomOffsetNomMonitor DisplayString Size(0..80)
  lmemajorHighOffsetNomMonitor Float
  lmemajorLowOffsetNomMonitor Float
  lmeminorHighOffsetNomMonitor Float
  lmeminorLowOffsetNomMonitor Float
  lmecurrentValueOffsetNomMonitor Float
  lmestateFlagOffsetNomMonitor INTEGER
  lmeminValueOffsetNomMonitor Float
  lmemaxValueOffsetNomMonitor Float
  lmealarmStateOffsetNomMonitor INTEGER
  lmelabelOffsetNomCnt DisplayString Size(0..80)
  lmeuomOffsetNomCnt DisplayString Size(0..80)
  lmemajorHighOffsetNomCnt Float
  lmemajorLowOffsetNomCnt Float
  lmeminorHighOffsetNomCnt Float
  lmeminorLowOffsetNomCnt Float
  lmecurrentValueOffsetNomCnt Float
  lmestateFlagOffsetNomCnt INTEGER
  lmeminValueOffsetNomCnt Float
  lmemaxValueOffsetNomCnt Float
  lmealarmStateOffsetNomCnt INTEGER
  lmelabelRelAttenSetting DisplayString Size(0..80)
  lmeuomRelAttenSetting DisplayString Size(0..80)
  lmemajorHighRelAttenSetting Float
  lmemajorLowRelAttenSetting Float
  lmeminorHighRelAttenSetting Float
  lmeminorLowRelAttenSetting Float
  lmecurrentValueRelAttenSetting Float
  lmestateFlagRelAttenSetting INTEGER
  lmeminValueRelAttenSetting Float
  lmemaxValueRelAttenSetting Float
  lmealarmStateRelAttenSetting INTEGER
  lmelabelOptPower DisplayString Size(0..80)
  lmeuomOptPower DisplayString Size(0..80)
  lmemajorHighOptPower Float
  lmemajorLowOptPower Float
  lmeminorHighOptPower Float
  lmeminorLowOptPower Float
  lmecurrentValueOptPower Float
  lmestateFlagOptPower INTEGER
  lmeminValueOptPower Float
  lmemaxValueOptPower Float
  lmealarmStateOptPower INTEGER
  lmelabelLaserBias DisplayString Size(0..80)
  lmeuomLaserBias DisplayString Size(0..80)
  lmemajorHighLaserBias Float
  lmemajorLowLaserBias Float
  lmeminorHighLaserBias Float
  lmeminorLowLaserBias Float
  lmecurrentValueLaserBias Float
  lmestateFlagLaserBias INTEGER
  lmeminValueLaserBias Float
  lmemaxValueLaserBias Float
  lmealarmStateLaserBias INTEGER
  lmelabelTecCurrent DisplayString Size(0..80)
  lmeuomTecCurrent DisplayString Size(0..80)
  lmemajorHighTecCurrent Float
  lmemajorLowTecCurrent Float
  lmeminorHighTecCurrent Float
  lmeminorLowTecCurrent Float
  lmecurrentValueTecCurrent Float
  lmestateFlagTecCurrent INTEGER
  lmeminValueTecCurrent Float
  lmemaxValueTecCurrent Float
  lmealarmStateTecCurrent INTEGER
  lmelabelLaserTemp DisplayString Size(0..80)
  lmeuomLaserTemp DisplayString Size(0..80)
  lmemajorHighLaserTemp Float
  lmemajorLowLaserTemp Float
  lmeminorHighLaserTemp Float
  lmeminorLowLaserTemp Float
  lmecurrentValueLaserTemp Float
  lmestateFlagLaserTemp INTEGER
  lmeminValueLaserTemp Float
  lmemaxValueLaserTemp Float
  lmealarmStateLaserTemp INTEGER
  lmelabelModuleTemp DisplayString Size(0..80)
  lmeuomModuleTemp DisplayString Size(0..80)
  lmemajorHighModuleTemp Float
  lmemajorLowModuleTemp Float
  lmeminorHighModuleTemp Float
  lmeminorLowModuleTemp Float
  lmecurrentValueModuleTemp Float
  lmestateFlagModuleTemp INTEGER
  lmeminValueModuleTemp Float
  lmemaxValueModuleTemp Float
  lmealarmStateModuleTemp INTEGER
  lmelabelFanCurrent DisplayString Size(0..80)
  lmeuomFanCurrent DisplayString Size(0..80)
  lmemajorHighFanCurrent Float
  lmemajorLowFanCurrent Float
  lmeminorHighFanCurrent Float
  lmeminorLowFanCurrent Float
  lmecurrentValueFanCurrent Float
  lmestateFlagFanCurrent INTEGER
  lmeminValueFanCurrent Float
  lmemaxValueFanCurrent Float
  lmealarmStateFanCurrent INTEGER
  lmelabel12Volt DisplayString Size(0..80)
  lmeuom12Volt DisplayString Size(0..80)
  lmemajorHigh12Volt Float
  lmemajorLow12Volt Float
  lmeminorHigh12Volt Float
  lmeminorLow12Volt Float
  lmecurrentValue12Volt Float
  lmestateFlag12Volt INTEGER
  lmeminValue12Volt Float
  lmemaxValue12Volt Float
  lmealarmState12Volt INTEGER

Gx2lmeDigitalEntry  
SEQUENCE    
  gx2lmeDigitalTableIndex INTEGER
  lmelabelRfInput DisplayString Size(0..80)
  lmeenumRfInput DisplayString Size(0..80)
  lmevalueRfInput INTEGER
  lmestateflagRfInput INTEGER
  lmelabelOptOutput DisplayString Size(0..80)
  lmeenumOptOutput DisplayString Size(0..80)
  lmevalueOptOutput INTEGER
  lmestateflagOptOutput INTEGER
  lmelabelLaserMode DisplayString Size(0..80)
  lmeenumLaserMode DisplayString Size(0..80)
  lmevalueLaserMode INTEGER
  lmestateflagLaserMode INTEGER
  lmelabelLaserSecMode DisplayString Size(0..80)
  lmeenumLaserSecMode DisplayString Size(0..80)
  lmevalueLaserSecMode INTEGER
  lmestateflagLaserSecMode INTEGER
  lmelabelVideoOffset DisplayString Size(0..80)
  lmeenumVideoOffset DisplayString Size(0..80)
  lmevalueVideoOffset INTEGER
  lmestateflagVideoOffset INTEGER
  lmelabelFactoryDefault DisplayString Size(0..80)
  lmeenumFactoryDefault DisplayString Size(0..80)
  lmevalueFactoryDefault INTEGER
  lmestateflagFactoryDefault INTEGER
  lmelabelFiberLength DisplayString Size(0..80)
  lmeenumFiberLength DisplayString Size(0..80)
  lmevalueFiberLength INTEGER
  lmestateflagFiberLength INTEGER
  lmelabelConditioningUnit DisplayString Size(0..80)
  lmeenumConditioningUnit DisplayString Size(0..80)
  lmevalueConditioningUnit INTEGER
  lmestateflagConditioningUnit INTEGER

Gx2lmeStatusEntry  
SEQUENCE    
  gx2lmeStatusTableIndex INTEGER
  lmelabelBoot DisplayString Size(0..80)
  lmevalueBoot INTEGER
  lmestateflagBoot INTEGER
  lmelabelFlash DisplayString Size(0..80)
  lmevalueFlash INTEGER
  lmestateflagFlash INTEGER
  lmelabelFactoryDataCRC DisplayString Size(0..80)
  lmevalueFactoryDataCRC INTEGER
  lmestateflagFactoryDataCRC INTEGER
  lmelabelLaserDataCRC DisplayString Size(0..80)
  lmevalueLaserDataCRC INTEGER
  lmestateflagLaserDataCRC INTEGER
  lmelabelAlarmDataCrc DisplayString Size(0..80)
  lmevalueAlarmDataCrc INTEGER
  lmestateflagAlarmDataCrc INTEGER
  lmelabelHWStatus DisplayString Size(0..80)
  lmevalueHWStatus INTEGER
  lmestateflagHWStatus INTEGER
  lmelabelRFInputStatus DisplayString Size(0..80)
  lmevalueRFInputStatus INTEGER
  lmestateflagRFInputStatus INTEGER

Gx2lmeFactoryEntry  
SEQUENCE    
  gx2lmeFactoryTableIndex INTEGER
  lmebootControlByteValue INTEGER
  lmebootStatusByteValue INTEGER
  lmebank1CRCValue INTEGER
  lmebank2CRCValue INTEGER
  lmeprgEEPROMByteValue INTEGER
  lmefactoryCRCValue INTEGER
  lmecalculateCRCValue INTEGER
  lmehourMeterValue INTEGER
  lmeflashPrgCntAValue INTEGER
  lmeflashPrgCntBValue INTEGER
  lmeflashBankARevValue DisplayString Size(0..80)
  lmeflashBankBRevValue DisplayString Size(0..80)

Gx2Lm1000EHoldTimeEntry  
SEQUENCE    
  gx2Lm1000EHoldTimeTableIndex INTEGER
  gx2Lm1000EHoldTimeSpecIndex INTEGER
  gx2Lm1000EHoldTimeData INTEGER

Defined Values

gx2lmeDescriptor 1.3.6.1.4.1.1166.6.1.2.27.1
OBJECT IDENTIFIER    

gx2lmeAnalogTable 1.3.6.1.4.1.1166.6.1.2.27.2
This table contains gx2LmE specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2lmeAnalogEntry

gx2lmeAnalogEntry 1.3.6.1.4.1.1166.6.1.2.27.2.1
This list contains the analog parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2lmeAnalogEntry  

gx2lmeDigitalTable 1.3.6.1.4.1.1166.6.1.2.27.3
This table contains gx2LmE specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2lmeDigitalEntry

gx2lmeDigitalEntry 1.3.6.1.4.1.1166.6.1.2.27.3.2
This list contains digital parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2lmeDigitalEntry  

gx2lmeStatusTable 1.3.6.1.4.1.1166.6.1.2.27.4
This table contains gx2LmE specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2lmeStatusEntry

gx2lmeStatusEntry 1.3.6.1.4.1.1166.6.1.2.27.4.3
This list contains Status parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2lmeStatusEntry  

gx2lmeFactoryTable 1.3.6.1.4.1.1166.6.1.2.27.5
This table contains gx2LmE specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2lmeFactoryEntry

gx2lmeFactoryEntry 1.3.6.1.4.1.1166.6.1.2.27.5.4
This list contains Factory parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2lmeFactoryEntry  

gx2Lm1000EHoldTimeTable 1.3.6.1.4.1.1166.6.1.2.27.6
This table contains gx2Lm1000E specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2Lm1000EHoldTimeEntry

gx2Lm1000EHoldTimeEntry 1.3.6.1.4.1.1166.6.1.2.27.6.5
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2Lm1000EHoldTimeEntry  

gx2lmeAnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.27.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

lmelabelOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.27.2.1.2
The value of this object provides the label of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeuomOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.27.2.1.3
The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmemajorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.27.2.1.4
The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemajorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.27.2.1.5
The value of this object provides the Major Low alarm value of the Offset Monitor Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorHighOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.27.2.1.6
The value of this object provides the Minor High alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorLowOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.27.2.1.7
The value of this object provides the Minor Low alarm value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmecurrentValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.27.2.1.8
The value of this object provides the Current value of the Offset Monitor Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmestateFlagOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.27.2.1.9
The value of this object provides the state of the Offset Monitor Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmeminValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.27.2.1.10
The value of this object provides the minimum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemaxValueOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.27.2.1.11
The value of this object provides the maximum value the Offset Monitor Analog parameter can achive. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmealarmStateOffsetNomMonitor 1.3.6.1.4.1.1166.6.1.2.27.2.1.12
The value of this object provides the curent alarm state of the Offset Monitor Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

lmelabelOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.27.2.1.13
The value of this object provides the label of the Offset Control Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeuomOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.27.2.1.14
The value of this object provides the label of the Offset Control Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmemajorHighOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.27.2.1.15
The value of this object provides the Major High alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemajorLowOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.27.2.1.16
The value of this object provides the Major Low alarm value of the Offset Control Analog parameter. This value is a float and is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorHighOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.27.2.1.17
The value of this object provides the Minor High alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorLowOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.27.2.1.18
The value of this object provides the Minor Low alarm value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmecurrentValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.27.2.1.19
The value of this object provides the Current value of the Offset Control Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

lmestateFlagOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.27.2.1.20
The value of this object provides the state of the Offset Control Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmeminValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.27.2.1.21
The value of this object provides the minimum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemaxValueOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.27.2.1.22
The value of this object provides the maximum value the Offset Control Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmealarmStateOffsetNomCnt 1.3.6.1.4.1.1166.6.1.2.27.2.1.23
The value of this object provides the curent alarm state of the Offset Control Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

lmelabelRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.27.2.1.24
The value of this object provides the label of the Attenuator Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeuomRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.27.2.1.25
The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmemajorHighRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.27.2.1.26
The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemajorLowRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.27.2.1.27
The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorHighRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.27.2.1.28
The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorLowRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.27.2.1.29
The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmecurrentValueRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.27.2.1.30
The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

lmestateFlagRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.27.2.1.31
The value of this object provides the state of the Attenuator Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmeminValueRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.27.2.1.32
The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemaxValueRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.27.2.1.33
The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmealarmStateRelAttenSetting 1.3.6.1.4.1.1166.6.1.2.27.2.1.34
The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

lmelabelOptPower 1.3.6.1.4.1.1166.6.1.2.27.2.1.35
The value of this object provides the label of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeuomOptPower 1.3.6.1.4.1.1166.6.1.2.27.2.1.36
The value of this object provides the Unit of Measure of the Optical Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmemajorHighOptPower 1.3.6.1.4.1.1166.6.1.2.27.2.1.37
The value of this object provides the Major High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemajorLowOptPower 1.3.6.1.4.1.1166.6.1.2.27.2.1.38
The value of this object provides the Major Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorHighOptPower 1.3.6.1.4.1.1166.6.1.2.27.2.1.39
The value of this object provides the Minor High alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorLowOptPower 1.3.6.1.4.1.1166.6.1.2.27.2.1.40
The value of this object provides the Minor Low alarm value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmecurrentValueOptPower 1.3.6.1.4.1.1166.6.1.2.27.2.1.41
The value of this object provides the Current value of the Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmestateFlagOptPower 1.3.6.1.4.1.1166.6.1.2.27.2.1.42
The value of this object provides the state of the Optical Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmeminValueOptPower 1.3.6.1.4.1.1166.6.1.2.27.2.1.43
The value of this object provides the minimum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemaxValueOptPower 1.3.6.1.4.1.1166.6.1.2.27.2.1.44
The value of this object provides the maximum value the Optical Power Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmealarmStateOptPower 1.3.6.1.4.1.1166.6.1.2.27.2.1.45
The value of this object provides the curent alarm state of the Optical Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

lmelabelLaserBias 1.3.6.1.4.1.1166.6.1.2.27.2.1.46
The value of this object provides the label of the Laser Bias Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeuomLaserBias 1.3.6.1.4.1.1166.6.1.2.27.2.1.47
The value of this object provides the Unit of Measure of the Laser Bias Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmemajorHighLaserBias 1.3.6.1.4.1.1166.6.1.2.27.2.1.48
The value of this object provides the Major High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemajorLowLaserBias 1.3.6.1.4.1.1166.6.1.2.27.2.1.49
The value of this object provides the Major Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorHighLaserBias 1.3.6.1.4.1.1166.6.1.2.27.2.1.50
The value of this object provides the Minor High alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorLowLaserBias 1.3.6.1.4.1.1166.6.1.2.27.2.1.51
The value of this object provides the Minor Low alarm value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmecurrentValueLaserBias 1.3.6.1.4.1.1166.6.1.2.27.2.1.52
The value of this object provides the Current value of the Laser Bias Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmestateFlagLaserBias 1.3.6.1.4.1.1166.6.1.2.27.2.1.53
The value of this object provides the state of the Laser Bias Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmeminValueLaserBias 1.3.6.1.4.1.1166.6.1.2.27.2.1.54
The value of this object provides the minimum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemaxValueLaserBias 1.3.6.1.4.1.1166.6.1.2.27.2.1.55
The value of this object provides the maximum value the Laser Bias Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmealarmStateLaserBias 1.3.6.1.4.1.1166.6.1.2.27.2.1.56
The value of this object provides the curent alarm state of the Laser Bias Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

lmelabelTecCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.57
The value of this object provides the label of the TEC Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeuomTecCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.58
The value of this object provides the Unit of Measure of the TEC Current Analog parameter..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmemajorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.59
The value of this object provides the Major High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemajorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.60
The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorHighTecCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.61
The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorLowTecCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.62
The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmecurrentValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.63
The value of this object provides the Current value of the TEC Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmestateFlagTecCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.64
The value of this object provides the state of the TEC Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmeminValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.65
The value of this object provides the minimum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemaxValueTecCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.66
The value of this object provides the maximum value the TEC Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmealarmStateTecCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.67
The value of this object provides the curent alarm state of the TEC Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

lmelabelLaserTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.68
The value of this object provides the label of the Laser Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeuomLaserTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.69
The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmemajorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.70
The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemajorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.71
The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorHighLaserTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.72
The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorLowLaserTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.73
The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmecurrentValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.74
The value of this object provides the Current value of the Laser Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmestateFlagLaserTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.75
The value of this object provides the state of the Laser Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmeminValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.76
The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemaxValueLaserTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.77
The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmealarmStateLaserTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.78
The value of this object provides the curent alarm state of the Laser Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

lmelabelModuleTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.79
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeuomModuleTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.80
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmemajorHighModuleTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.81
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemajorLowModuleTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.82
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorHighModuleTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.83
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorLowModuleTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.84
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmecurrentValueModuleTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.85
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmestateFlagModuleTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.86
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmeminValueModuleTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.87
The value of this object provides the minimum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemaxValueModuleTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.88
The value of this object provides the maximum value the Module Temperature Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmealarmStateModuleTemp 1.3.6.1.4.1.1166.6.1.2.27.2.1.89
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

lmelabelFanCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.90
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeuomFanCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.91
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmemajorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.92
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemajorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.93
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.94
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.95
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmecurrentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.96
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmestateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.97
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmeminValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.98
The value of this object provides the minimum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemaxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.99
The value of this object provides the maximum value the Fan Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmealarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.27.2.1.100
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

lmelabel12Volt 1.3.6.1.4.1.1166.6.1.2.27.2.1.101
The value of this object provides the label of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeuom12Volt 1.3.6.1.4.1.1166.6.1.2.27.2.1.102
The value of this object provides the Unit of Measure of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmemajorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.27.2.1.103
The value of this object provides the Major High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemajorLow12Volt 1.3.6.1.4.1.1166.6.1.2.27.2.1.104
The value of this object provides the Major Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorHigh12Volt 1.3.6.1.4.1.1166.6.1.2.27.2.1.105
The value of this object provides the Minor High alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmeminorLow12Volt 1.3.6.1.4.1.1166.6.1.2.27.2.1.106
The value of this object provides the Minor Low alarm value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmecurrentValue12Volt 1.3.6.1.4.1.1166.6.1.2.27.2.1.107
The value of this object provides the Current value of the 12v Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmestateFlag12Volt 1.3.6.1.4.1.1166.6.1.2.27.2.1.108
The value of this object provides the state of the 12v Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmeminValue12Volt 1.3.6.1.4.1.1166.6.1.2.27.2.1.109
The value of this object provides the minimum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmemaxValue12Volt 1.3.6.1.4.1.1166.6.1.2.27.2.1.110
The value of this object provides the maximum value the 12v Current Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

lmealarmState12Volt 1.3.6.1.4.1.1166.6.1.2.27.2.1.111
The value of this object provides the curent alarm state of the 12v Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2lmeDigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.27.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

lmelabelRfInput 1.3.6.1.4.1.1166.6.1.2.27.3.2.2
The value of this object provides the label of the RF Input Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeenumRfInput 1.3.6.1.4.1.1166.6.1.2.27.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueRfInput 1.3.6.1.4.1.1166.6.1.2.27.3.2.4
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

lmestateflagRfInput 1.3.6.1.4.1.1166.6.1.2.27.3.2.5
The value of this object provides the state of the RF Input Control Digital parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelOptOutput 1.3.6.1.4.1.1166.6.1.2.27.3.2.6
The value of this object provides the label of the Optical Output Control Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeenumOptOutput 1.3.6.1.4.1.1166.6.1.2.27.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueOptOutput 1.3.6.1.4.1.1166.6.1.2.27.3.2.8
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

lmestateflagOptOutput 1.3.6.1.4.1.1166.6.1.2.27.3.2.9
The value of this object provides the lmestate of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelLaserMode 1.3.6.1.4.1.1166.6.1.2.27.3.2.10
The value of this object provides the label of the Laser Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeenumLaserMode 1.3.6.1.4.1.1166.6.1.2.27.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueLaserMode 1.3.6.1.4.1.1166.6.1.2.27.3.2.12
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER preset(1), set(2), setEquate(3), manual(4), manualEquate(5)  

lmestateflagLaserMode 1.3.6.1.4.1.1166.6.1.2.27.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelLaserSecMode 1.3.6.1.4.1.1166.6.1.2.27.3.2.14
The value of this object provides the label of the Laser Secondary Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeenumLaserSecMode 1.3.6.1.4.1.1166.6.1.2.27.3.2.15
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueLaserSecMode 1.3.6.1.4.1.1166.6.1.2.27.3.2.16
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cw(1), video(2)  

lmestateflagLaserSecMode 1.3.6.1.4.1.1166.6.1.2.27.3.2.17
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelVideoOffset 1.3.6.1.4.1.1166.6.1.2.27.3.2.18
The value of this object provides the label of the Video Offset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeenumVideoOffset 1.3.6.1.4.1.1166.6.1.2.27.3.2.19
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1..
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueVideoOffset 1.3.6.1.4.1.1166.6.1.2.27.3.2.20
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER minus2dB(1), minus3dB(2), minus4dB(3), minus5dB(4)  

lmestateflagVideoOffset 1.3.6.1.4.1.1166.6.1.2.27.3.2.21
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.27.3.2.22
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeenumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.27.3.2.23
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.27.3.2.24
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

lmestateflagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.27.3.2.25
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelFiberLength 1.3.6.1.4.1.1166.6.1.2.27.3.2.26
This object is only used for the LC1000 device family. The value of this object provides the label for the Fiber Length Digital parameter .
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeenumFiberLength 1.3.6.1.4.1.1166.6.1.2.27.3.2.27
This object is only used for the LC1000 device family. The value of this object represents the Enumeration values possible for the Digital parameter. The range for fiber length selection is from 6 to 25km, where 6km is represented with a 1 and 25 with a 19.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueFiberLength 1.3.6.1.4.1.1166.6.1.2.27.3.2.28
This object is only used for the LC1000 device family. The value of this object is the current value of the parameter. It is used to set fiber length. The value range for this object is: 0 to 30 Km.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fl6km(1), fl7km(2), fl8km(3), fl9km(4), fl10km(5), fl11km(6), fl12km(7), fl13km(8), fl14km(9), fl15km(10), fl16km(11), fl17km(12), fl18km(13), fl19km(14), fl20km(15), fl21km(16), fl22km(17), fl23km(18), fl24km(19), fl25km(20)  

lmestateflagFiberLength 1.3.6.1.4.1.1166.6.1.2.27.3.2.29
This object is only used for the LC1000 device family. The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelConditioningUnit 1.3.6.1.4.1.1166.6.1.2.27.3.2.30
This object is only used for the LC1000 device family. The value of this object provides the label for the Conditioning Unit Digital parameter .
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeenumConditioningUnit 1.3.6.1.4.1.1166.6.1.2.27.3.2.31
This object is only used for the LC1000 device family. The value of this object represents the Enumeration values possible for the Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueConditioningUnit 1.3.6.1.4.1.1166.6.1.2.27.3.2.32
This object is only used for the LC1000 device family. The value of this object is the current value of the parameter. It is used to normalize the output by -3db when a conditioning unit is being used in the system.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

lmestateflagConditioningUnit 1.3.6.1.4.1.1166.6.1.2.27.3.2.33
This object is only used for the LC1000 device family. The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2lmeStatusTableIndex 1.3.6.1.4.1.1166.6.1.2.27.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

lmelabelBoot 1.3.6.1.4.1.1166.6.1.2.27.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueBoot 1.3.6.1.4.1.1166.6.1.2.27.4.3.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

lmestateflagBoot 1.3.6.1.4.1.1166.6.1.2.27.4.3.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelFlash 1.3.6.1.4.1.1166.6.1.2.27.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueFlash 1.3.6.1.4.1.1166.6.1.2.27.4.3.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

lmestateflagFlash 1.3.6.1.4.1.1166.6.1.2.27.4.3.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.27.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.27.4.3.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

lmestateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.27.4.3.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.27.4.3.11
The value of this object provides the label of the Laser Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.27.4.3.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

lmestateflagLaserDataCRC 1.3.6.1.4.1.1166.6.1.2.27.4.3.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.27.4.3.14
The value of this object provides the label of the Alarm Data Crc parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.27.4.3.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

lmestateflagAlarmDataCrc 1.3.6.1.4.1.1166.6.1.2.27.4.3.16
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelHWStatus 1.3.6.1.4.1.1166.6.1.2.27.4.3.17
The value of this object provides the label of the Laser Drive Level Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueHWStatus 1.3.6.1.4.1.1166.6.1.2.27.4.3.18
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

lmestateflagHWStatus 1.3.6.1.4.1.1166.6.1.2.27.4.3.19
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

lmelabelRFInputStatus 1.3.6.1.4.1.1166.6.1.2.27.4.3.20
The value of this object provides the label of the RF Input Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmevalueRFInputStatus 1.3.6.1.4.1.1166.6.1.2.27.4.3.21
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

lmestateflagRFInputStatus 1.3.6.1.4.1.1166.6.1.2.27.4.3.22
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2lmeFactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.27.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

lmebootControlByteValue 1.3.6.1.4.1.1166.6.1.2.27.5.4.2
The value of this object indicates which bank the firmware is currently being boot from.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmebootStatusByteValue 1.3.6.1.4.1.1166.6.1.2.27.5.4.3
This object indicates the status of the last boot
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmebank1CRCValue 1.3.6.1.4.1.1166.6.1.2.27.5.4.4
This object provides the CRC code of bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmebank2CRCValue 1.3.6.1.4.1.1166.6.1.2.27.5.4.5
This object provides the CRC code of bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmeprgEEPROMByteValue 1.3.6.1.4.1.1166.6.1.2.27.5.4.6
This object indicates if the EEPROM has been programmed
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmefactoryCRCValue 1.3.6.1.4.1.1166.6.1.2.27.5.4.7
This object provides the CRC code for the Factory data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmecalculateCRCValue 1.3.6.1.4.1.1166.6.1.2.27.5.4.8
This object indicates which of the Emnums will have the CRC calculated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), laserData(2), alarm(3)  

lmehourMeterValue 1.3.6.1.4.1.1166.6.1.2.27.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmeflashPrgCntAValue 1.3.6.1.4.1.1166.6.1.2.27.5.4.10
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmeflashPrgCntBValue 1.3.6.1.4.1.1166.6.1.2.27.5.4.11
This object provides the number of times Bank 1 flash has been programmed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

lmeflashBankARevValue 1.3.6.1.4.1.1166.6.1.2.27.5.4.12
This object provides the revision of flash bank 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

lmeflashBankBRevValue 1.3.6.1.4.1.1166.6.1.2.27.5.4.13
This object provides the revision of flash bank 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gx2Lm1000EHoldTimeTableIndex 1.3.6.1.4.1.1166.6.1.2.27.6.5.1
The value of this object is the index of the data object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2Lm1000EHoldTimeSpecIndex 1.3.6.1.4.1.1166.6.1.2.27.6.5.2
The value of this object identifies the index of the alarm object to be modified.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2Lm1000EHoldTimeData 1.3.6.1.4.1.1166.6.1.2.27.6.5.3
The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

trapLMEConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapLMEConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapLMERFInputAlarm 3
This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapLMERFOverloadAlarm 4
This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapLMERFOffsetAlarm 5
This trap is issued when the Laser Modules RF Offset parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapLMEOpticalPowerAlarm 6
This trap is issued when the Laser Modules Optical Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapLMELaserBiasAlarm 7
This trap is issued when the Laser Bias parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapLMELaserTempAlarm 8
This trap is issued when the Laser Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapLMETECCurrentAlarm 9
This trap is issued when the Laser Modules TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapLMEFanCurrentAlarm 10
This trap is issued when the Laser Modules Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapLME12vAlarm 11
This trap is issued when the Laser Modules 12 Volt parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter.
TRAP-TYPE    

trapLMEModuleTempAlarm 12
This trap is issued when the Laser Module Temperature goes out of range.
TRAP-TYPE    

trapLMEFlashAlarm 13
This trap is issued when the Laser Modules detects an error during Flash memory operations.
TRAP-TYPE    

trapLMELaserBiasCntLoopAlarm 14
This trap is issued when the Laser Modules detects an error in its Laser Bias control loop operation.
TRAP-TYPE    

trapLMEBankBootAlarm 15
This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1.
TRAP-TYPE    

trapLMELaserBiasCntLoopInitAlarm 16
This trap is issued when the Laser Bias Control loop init fails.
TRAP-TYPE    

trapLMERFParamInitAlarm 17
This trap is issued when the RF parameter Init fails.
TRAP-TYPE    

trapLMETECParamInitAlarm 18
This trap is issued when the TEC Parameter Init fails.
TRAP-TYPE    

trapLMEAttnTableInitAlarm 19
This trap is issued when the Attenuator Table Init fails.
TRAP-TYPE    

trapLMEPowerMeterTableInitAlarm 20
This trap is issued when the Power Meter Table Init fails.
TRAP-TYPE    

trapLMELaserDataCRCAlarm 21
This trap is issued when the Laser Data CRC is incorrect.
TRAP-TYPE    

trapLMEAlarmDataCRCAlarm 22
This trap is issued when the Alarm Data CRC is incorrect.
TRAP-TYPE    

trapLMEFactoryDataCRCAlarm 23
This trap is issued when the Factory Data CRC is incorrect.
TRAP-TYPE    

trapLMEUserRFOffAlarm 24
This trap is issued when the the User RF is turned off.
TRAP-TYPE    

trapLMEUserOpticalOffAlarm 25
This trap is issued when the User Optical Power is turned off.
TRAP-TYPE    

trapLMEResetFactoryDefaultAlarm 26
This trap is issued when the Factory Default Reset occurs.
TRAP-TYPE