OMNI-gx2oa100bd-MIB

File: OMNI-gx2oa100bd-MIB.mib (140588 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215 NLS-BBNIDENT-MIB GX2HFC-MIB
NLSBBN-TRAPS-MIB

Imported symbols

IpAddress TimeTicks Counter
OBJECT-TYPE sysUpTime DisplayString
TRAP-TYPE gi motproxies
gx2OA100BD trapIdentifier trapNetworkElemModelNumber
trapNetworkElemSerialNum trapPerceivedSeverity trapNetworkElemOperState
trapNetworkElemAlarmStatus trapNetworkElemAdminState trapNetworkElemAvailStatus
trapText trapNETrapLastTrapTimeStamp trapChangedObjectId
trapChangedValueInteger trapChangedValueDisplayString

Defined Types

Float  
Counter    

Gx2OA100BDAnalogEntry  
SEQUENCE    
  gx2OA100BDAnalogTableIndex INTEGER
  oa100bdlabelModTemp DisplayString Size(0..80)
  oa100bduomModTemp DisplayString Size(0..80)
  oa100bdmajorHighModTemp Float
  oa100bdmajorLowModTemp Float
  oa100bdminorHighModTemp Float
  oa100bdminorLowModTemp Float
  oa100bdcurrentValueModTemp Float
  oa100bdstateFlagModTemp INTEGER
  oa100bdminValueModTemp Float
  oa100bdmaxValueModTemp Float
  oa100bdalarmStateModTemp INTEGER
  oa100bdlabelOptInPower DisplayString Size(0..80)
  oa100bduomOptInPower DisplayString Size(0..80)
  oa100bdmajorHighOptInPower Float
  oa100bdmajorLowOptInPower Float
  oa100bdminorHighOptInPower Float
  oa100bdminorLowOptInPower Float
  oa100bdcurrentValueOptInPower Float
  oa100bdstateFlagOptInPower INTEGER
  oa100bdminValueOptInPower Float
  oa100bdmaxValueOptInPower Float
  oa100bdalarmStateOptInPower INTEGER
  oa100bdlabelOptOutPower DisplayString Size(0..80)
  oa100bduomOptOutPower DisplayString Size(0..80)
  oa100bdmajorHighOptOutPower Float
  oa100bdmajorLowOptOutPower Float
  oa100bdminorHighOptOutPower Float
  oa100bdminorLowOptOutPower Float
  oa100bdcurrentValueOptOutPower Float
  oa100bdstateFlagOptOutPower INTEGER
  oa100bdminValueOptOutPower Float
  oa100bdmaxValueOptOutPower Float
  oa100bdalarmStateOptOutPower INTEGER
  oa100bdlabelMainTECTemp DisplayString Size(0..80)
  oa100bduomMainTECTemp DisplayString Size(0..80)
  oa100bdmajorHighMainTECTemp Float
  oa100bdmajorLowMainTECTemp Float
  oa100bdminorHighMainTECTemp Float
  oa100bdminorLowMainTECTemp Float
  oa100bdcurrentValueMainTECTemp Float
  oa100bdstateFlagMainTECTemp INTEGER
  oa100bdminValueMainTECTemp Float
  oa100bdmaxValueMainTECTemp Float
  oa100bdalarmStateMainTECTemp INTEGER
  oa100bdlabelMainLaserPower DisplayString Size(0..80)
  oa100bduomMainLaserPower DisplayString Size(0..80)
  oa100bdmajorHighMainLaserPower Float
  oa100bdmajorLowMainLaserPower Float
  oa100bdminorHighMainLaserPower Float
  oa100bdminorLowMainLaserPower Float
  oa100bdcurrentValueMainLaserPower Float
  oa100bdstateFlagMainLaserPower INTEGER
  oa100bdminValueMainLaserPower Float
  oa100bdmaxValueMainLaserPower Float
  oa100bdalarmStateMainLaserPower INTEGER
  oa100bdlabelAuxTECTemp DisplayString Size(0..80)
  oa100bduomAuxTECTemp DisplayString Size(0..80)
  oa100bdmajorHighAuxTECTemp Float
  oa100bdmajorLowAuxTECTemp Float
  oa100bdminorHighAuxTECTemp Float
  oa100bdminorLowAuxTECTemp Float
  oa100bdcurrentValueAuxTECTemp Float
  oa100bdstateFlagAuxTECTemp INTEGER
  oa100bdminValueAuxTECTemp Float
  oa100bdmaxValueAuxTECTemp Float
  oa100bdalarmStateAuxTECTemp INTEGER
  oa100bdlabelAuxLaserPower DisplayString Size(0..80)
  oa100bduomAuxLaserPower DisplayString Size(0..80)
  oa100bdmajorHighAuxLaserPower Float
  oa100bdmajorLowAuxLaserPower Float
  oa100bdminorHighAuxLaserPower Float
  oa100bdminorLowAuxLaserPower Float
  oa100bdcurrentValueAuxLaserPower Float
  oa100bdstateFlagAuxLaserPower INTEGER
  oa100bdminValueAuxLaserPower Float
  oa100bdmaxValueAuxLaserPower Float
  oa100bdalarmStateAuxLaserPower INTEGER
  oa100bdlabelFanCurrent DisplayString Size(0..80)
  oa100bduomFanCurrent DisplayString Size(0..80)
  oa100bdmajorHighFanCurrent Float
  oa100bdmajorLowFanCurrent Float
  oa100bdminorHighFanCurrent Float
  oa100bdminorLowFanCurrent Float
  oa100bdcurrentValueFanCurrent Float
  oa100bdstateFlagFanCurrent INTEGER
  oa100bdminValueFanCurrent Float
  oa100bdmaxValueFanCurrent Float
  oa100bdalarmStateFanCurrent INTEGER
  oa100bdlabelOPSetting DisplayString Size(0..80)
  oa100bduomOPSetting DisplayString Size(0..80)
  oa100bdmajorHighOPSetting Float
  oa100bdmajorLowOPSetting Float
  oa100bdminorHighOPSetting Float
  oa100bdminorLowOPSetting Float
  oa100bdcurrentValueOPSetting Float
  oa100bdstateFlagOPSetting INTEGER
  oa100bdminValueOPSetting Float
  oa100bdmaxValueOPSetting Float
  oa100bdalarmStateOPSetting INTEGER
  oa100bdlabelLPSetting DisplayString Size(0..80)
  oa100bduomLPSetting DisplayString Size(0..80)
  oa100bdmajorHighLPSetting Float
  oa100bdmajorLowLPSetting Float
  oa100bdminorHighLPSetting Float
  oa100bdminorLowLPSetting Float
  oa100bdcurrentValueLPSetting Float
  oa100bdstateFlagLPSetting INTEGER
  oa100bdminValueLPSetting Float
  oa100bdmaxValueLPSetting Float
  oa100bdalarmStateLPSetting INTEGER
  oa100bdlabelCGSetting DisplayString Size(0..80)
  oa100bduomCGSetting DisplayString Size(0..80)
  oa100bdmajorHighCGSetting Float
  oa100bdmajorLowCGSetting Float
  oa100bdminorHighCGSetting Float
  oa100bdminorLowCGSetting Float
  oa100bdcurrentValueCGSetting Float
  oa100bdstateFlagCGSetting INTEGER
  oa100bdminValueCGSetting Float
  oa100bdmaxValueCGSetting Float
  oa100bdalarmStateCGSetting INTEGER
  oa100bdlabelOptThreshold DisplayString Size(0..80)
  oa100bduomOptThreshold DisplayString Size(0..80)
  oa100bdmajorHighOptThreshold Float
  oa100bdmajorLowOptThreshold Float
  oa100bdminorHighOptThreshold Float
  oa100bdminorLowOptThreshold Float
  oa100bdcurrentValueOptThreshold Float
  oa100bdstateFlagOptThreshold INTEGER
  oa100bdminValueOptThreshold Float
  oa100bdmaxValueOptThreshold Float
  oa100bdalarmStateOptThreshold INTEGER

Gx2OA100BDDigitalEntry  
SEQUENCE    
  gx2OA100BDDigitalTableIndex INTEGER
  oa100bdlabelModeSetting DisplayString Size(0..80)
  oa100bdvalueModeSetting INTEGER
  oa100bdenumModeSetting DisplayString Size(0..80)
  oa100bdstateFlagModeSetting INTEGER
  oa100bdlabelModuleState DisplayString Size(0..80)
  oa100bdvalueModuleState INTEGER
  oa100bdenumModuleState DisplayString Size(0..80)
  oa100bdstateFlagModuleState INTEGER
  oa100bdlabelFactoryDefault DisplayString Size(0..80)
  oa100bdvalueFactoryDefault INTEGER
  oa100bdenumFactoryDefault DisplayString Size(0..80)
  oa100bdstateFlagFactoryDefault INTEGER

Gx2OA100BDStatusEntry  
SEQUENCE    
  gx2OA100BDStatusTableIndex INTEGER
  oa100bdlabelBoot DisplayString Size(0..80)
  oa100bdvalueBoot INTEGER
  oa100bdstateflagBoot INTEGER
  oa100bdlabelFlash DisplayString Size(0..80)
  oa100bdvalueFlash INTEGER
  oa100bdstateflagFlash INTEGER
  oa100bdlabelFactoryDataCRC DisplayString Size(0..80)
  oa100bdvalueFactoryDataCRC INTEGER
  oa100bdstateflagFactoryDataCRC INTEGER
  oa100bdlabelAlarmDataCRC DisplayString Size(0..80)
  oa100bdvalueAlarmDataCRC INTEGER
  oa100bdstateflagAlarmDataCRC INTEGER
  oa100bdlabelCalibrationDataCRC DisplayString Size(0..80)
  oa100bdvalueCalibrationDataCRC INTEGER
  oa100bdstateflagCalibrationDataCRC INTEGER
  oa100bdlabelOptInShutdown DisplayString Size(0..80)
  oa100bdvalueOptInShutdown INTEGER
  oa100bdstateflagOptInShutdown INTEGER
  oa100bdlabelMainTECTempShutdown DisplayString Size(0..80)
  oa100bdvalueMainTECTempShutdown INTEGER
  oa100bdstateflagMainTECTempShutdown INTEGER
  oa100bdlabelAuxTECTempShutdown DisplayString Size(0..80)
  oa100bdvalueAuxTECTempShutdown INTEGER
  oa100bdstateflagAuxTECTempShutdown INTEGER
  oa100bdlabelPowerFail DisplayString Size(0..80)
  oa100bdvaluePowerFail INTEGER
  oa100bdstateflagPowerFail INTEGER
  oa100bdlabelKeySwitch DisplayString Size(0..80)
  oa100bdvalueKeySwitch INTEGER
  oa100bdstateflagKeySwitch INTEGER
  oa100bdlabelMainLaserCurrShutdown DisplayString Size(0..80)
  oa100bdvalueMainLaserCurrShutdown INTEGER
  oa100bdstateflagMainLaserCurrShutdown INTEGER
  oa100bdlabelAuxLaserCurrShutdown DisplayString Size(0..80)
  oa100bdvalueAuxLaserCurrShutdown INTEGER
  oa100bdstateflagAuxLaserCurrShutdown INTEGER
  oa100bdlabelMainLaserPowShutdown DisplayString Size(0..80)
  oa100bdvalueMainLaserPowShutdown INTEGER
  oa100bdstateflagMainLaserPowShutdown INTEGER
  oa100bdlabelAuxLaserPowShutdown DisplayString Size(0..80)
  oa100bdvalueAuxLaserPowShutdown INTEGER
  oa100bdstateflagAuxLaserPowShutdown INTEGER
  oa100bdlabelADCStatus DisplayString Size(0..80)
  oa100bdvalueADCStatus INTEGER
  oa100bdstateflagADCStatus INTEGER
  oa100bdlabelConstGainStatus DisplayString Size(0..80)
  oa100bdvalueConstGainStatus INTEGER
  oa100bdstateflagConstGainStatus INTEGER
  oa100bdlabelHardwareErrorStatus DisplayString Size(0..80)
  oa100bdvalueHardwareErrorStatus INTEGER
  oa100bdstateflagHardwareErrorStatus INTEGER
  oa100bdlabelStandbyStatus DisplayString Size(0..80)
  oa100bdvalueStandbyStatus INTEGER
  oa100bdstateflagStandbyStatus INTEGER

Gx2OA100BDFactoryEntry  
SEQUENCE    
  gx2OA100BDFactoryTableIndex INTEGER
  oa100bdbootControlByte INTEGER
  oa100bdbootStatusByte INTEGER
  oa100bdbank0CRC INTEGER
  oa100bdbank1CRC INTEGER
  oa100bdprgEEPROMByte INTEGER
  oa100bdfactoryCRC INTEGER
  oa100bdcalculateCRC INTEGER
  oa100bdhourMeter INTEGER
  oa100bdflashPrgCntA INTEGER
  oa100bdflashPrgCntB INTEGER
  oa100bdfwRev0 DisplayString Size(0..80)
  oa100bdfwRev1 DisplayString Size(0..80)

Gx2OA100BDHoldTimeEntry  
SEQUENCE    
  gx2OA100BDHoldTimeTableIndex INTEGER
  gx2OA100BDHoldTimeSpecIndex INTEGER
  gx2OA100BDHoldTimeData INTEGER

Defined Values

gx2OA100BDDescriptor 1.3.6.1.4.1.1166.6.1.2.17.1
OBJECT IDENTIFIER    

gx2OA100BDAnalogTable 1.3.6.1.4.1.1166.6.1.2.17.2
This table contains gx2OA100B specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2OA100BDAnalogEntry

gx2OA100BDAnalogEntry 1.3.6.1.4.1.1166.6.1.2.17.2.1
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2OA100BDAnalogEntry  

gx2OA100BDDigitalTable 1.3.6.1.4.1.1166.6.1.2.17.3
This table contains gx2OA100B specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2OA100BDDigitalEntry

gx2OA100BDDigitalEntry 1.3.6.1.4.1.1166.6.1.2.17.3.2
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2OA100BDDigitalEntry  

gx2OA100BDStatusTable 1.3.6.1.4.1.1166.6.1.2.17.4
This table contains gx2OA100B specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2OA100BDStatusEntry

gx2OA100BDStatusEntry 1.3.6.1.4.1.1166.6.1.2.17.4.3
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2OA100BDStatusEntry  

gx2OA100BDFactoryTable 1.3.6.1.4.1.1166.6.1.2.17.5
This table contains gx2OA100B specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2OA100BDFactoryEntry

gx2OA100BDFactoryEntry 1.3.6.1.4.1.1166.6.1.2.17.5.4
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2OA100BDFactoryEntry  

gx2OA100BDHoldTimeTable 1.3.6.1.4.1.1166.6.1.2.17.6
This table contains gx2OA100BD specific parameters with nominal and current values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Gx2OA100BDHoldTimeEntry

gx2OA100BDHoldTimeEntry 1.3.6.1.4.1.1166.6.1.2.17.6.5
This list contains digital product class and the associated RF channel parameters and descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Gx2OA100BDHoldTimeEntry  

gx2OA100BDAnalogTableIndex 1.3.6.1.4.1.1166.6.1.2.17.2.1.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

oa100bdlabelModTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.2
The value of this object provides the label of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bduomModTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.3
The value of this object provides the Unit of Measure of the Module Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdmajorHighModTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.4
The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmajorLowModTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.5
The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorHighModTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.6
The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorLowModTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.7
The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdcurrentValueModTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.8
The value of this object provides the Current value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdstateFlagModTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.9
The value of this object provides the state of the Module Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdminValueModTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.10
The value of this object provides the minimum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmaxValueModTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.11
The value of this object provides the maximum value of the Module Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdalarmStateModTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.12
The value of this object provides the curent alarm state of the Module Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

oa100bdlabelOptInPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.13
The value of this object provides the label of the Optical Input Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bduomOptInPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.14
The value of this object provides the Unit of Measure of the Optical Input Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdmajorHighOptInPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.15
The value of this object provides the Major High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmajorLowOptInPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.16
The value of this object provides the Major Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorHighOptInPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.17
The value of this object provides the Minor High alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorLowOptInPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.18
The value of this object provides the Minor Low alarm value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdcurrentValueOptInPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.19
The value of this object provides the Current value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdstateFlagOptInPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.20
The value of this object provides the state of the Optical Input Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdminValueOptInPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.21
The value of this object provides the minimum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmaxValueOptInPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.22
The value of this object provides the maximum value of the Optical Input Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdalarmStateOptInPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.23
The value of this object provides the curent alarm state of the Optical Input Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

oa100bdlabelOptOutPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.24
The value of this object provides the label of the Optical Output Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bduomOptOutPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.25
The value of this object provides the Unit of Measure of the Optical Output Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdmajorHighOptOutPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.26
The value of this object provides the Major High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmajorLowOptOutPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.27
The value of this object provides the Major Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorHighOptOutPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.28
The value of this object provides the Minor High alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorLowOptOutPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.29
The value of this object provides the Minor Low alarm value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdcurrentValueOptOutPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.30
The value of this object provides the Current value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdstateFlagOptOutPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.31
The value of this object provides the state of the Optical Output Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdminValueOptOutPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.32
The value of this object provides the minimum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmaxValueOptOutPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.33
The value of this object provides the maximum value of the Optical Output Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdalarmStateOptOutPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.34
The value of this object provides the curent alarm state of the Optical Output Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

oa100bdlabelMainTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.35
The value of this object provides the label of the TEC Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bduomMainTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.36
The value of this object provides the Unit of Measure of the TEC Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdmajorHighMainTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.37
The value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmajorLowMainTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.38
The value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorHighMainTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.39
The value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorLowMainTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.40
The value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdcurrentValueMainTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.41
The value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdstateFlagMainTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.42
The value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdminValueMainTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.43
The value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmaxValueMainTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.44
The value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdalarmStateMainTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.45
The value of this object provides the curent alarm state of the TEC Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

oa100bdlabelMainLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.46
The value of this object provides the label of the Main Laser Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bduomMainLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.47
The value of this object provides the Unit of Measure of the Main Laser Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdmajorHighMainLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.48
The value of this object provides the Major High alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmajorLowMainLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.49
The value of this object provides the Major Low alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorHighMainLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.50
The value of this object provides the Minor High alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorLowMainLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.51
The value of this object provides the Minor Low alarm value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdcurrentValueMainLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.52
The value of this object provides the Current value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdstateFlagMainLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.53
The value of this object provides the state of the Main Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdminValueMainLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.54
The value of this object provides the minimum value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmaxValueMainLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.55
The value of this object provides the maximum value of the Main Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdalarmStateMainLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.56
The value of this object provides the curent alarm state of the Main Laser Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

oa100bdlabelAuxTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.57
The value of this object provides the label of the TEC Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bduomAuxTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.58
The value of this object provides the Unit of Measure of the TEC Temperature Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdmajorHighAuxTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.59
The value of this object provides the Major High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmajorLowAuxTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.60
The value of this object provides the Major Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorHighAuxTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.61
The value of this object provides the Minor High alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorLowAuxTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.62
The value of this object provides the Minor Low alarm value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdcurrentValueAuxTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.63
The value of this object provides the Current value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdstateFlagAuxTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.64
The value of this object provides the state of the TEC Temperature Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdminValueAuxTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.65
The value of this object provides the minimum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmaxValueAuxTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.66
The value of this object provides the maximum value of the TEC Temperature Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdalarmStateAuxTECTemp 1.3.6.1.4.1.1166.6.1.2.17.2.1.67
The value of this object provides the curent alarm state of the TEC Temperature Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

oa100bdlabelAuxLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.68
The value of this object provides the label of the Aux Laser Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bduomAuxLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.69
The value of this object provides the Unit of Measure of the Aux Laser Power Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdmajorHighAuxLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.70
The value of this object provides the Major High alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmajorLowAuxLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.71
The value of this object provides the Major Low alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorHighAuxLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.72
The value of this object provides the Minor High alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorLowAuxLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.73
The value of this object provides the Minor Low alarm value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdcurrentValueAuxLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.74
The value of this object provides the Current value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdstateFlagAuxLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.75
The value of this object provides the state of the Aux Laser Power Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdminValueAuxLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.76
The value of this object provides the minimum value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmaxValueAuxLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.77
The value of this object provides the maximum value of the Aux Laser Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdalarmStateAuxLaserPower 1.3.6.1.4.1.1166.6.1.2.17.2.1.78
The value of this object provides the curent alarm state of the Aux Laser Power Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

oa100bdlabelFanCurrent 1.3.6.1.4.1.1166.6.1.2.17.2.1.79
The value of this object provides the label of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bduomFanCurrent 1.3.6.1.4.1.1166.6.1.2.17.2.1.80
The value of this object provides the Unit of Measure of the Fan Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdmajorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.17.2.1.81
The value of this object provides the Major High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmajorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.17.2.1.82
The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorHighFanCurrent 1.3.6.1.4.1.1166.6.1.2.17.2.1.83
The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorLowFanCurrent 1.3.6.1.4.1.1166.6.1.2.17.2.1.84
The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdcurrentValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.17.2.1.85
The value of this object provides the Current value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdstateFlagFanCurrent 1.3.6.1.4.1.1166.6.1.2.17.2.1.86
The value of this object provides the state of the Fan Current Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdminValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.17.2.1.87
The value of this object provides the minimum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmaxValueFanCurrent 1.3.6.1.4.1.1166.6.1.2.17.2.1.88
The value of this object provides the maximum value of the Fan Current Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdalarmStateFanCurrent 1.3.6.1.4.1.1166.6.1.2.17.2.1.89
The value of this object provides the curent alarm state of the Fan Current Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

oa100bdlabelOPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.90
The value of this object provides the label of the Output Power Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bduomOPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.91
The value of this object provides the Unit of Measure of the 12v Current Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdmajorHighOPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.92
The value of this object provides the Major High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmajorLowOPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.93
The value of this object provides the Major Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorHighOPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.94
The value of this object provides the Minor High alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorLowOPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.95
The value of this object provides the Minor Low alarm value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdcurrentValueOPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.96
The value of this object provides the Current value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

oa100bdstateFlagOPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.97
The value of this object provides the state of the Output Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdminValueOPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.98
The value of this object provides the minimum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmaxValueOPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.99
The value of this object provides the maximum value of the Output Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdalarmStateOPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.100
The value of this object provides the curent alarm state of the Output Power Setting Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

oa100bdlabelLPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.101
The value of this object provides the label of the Laser Power Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bduomLPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.102
The value of this object provides the Unit of Measure of the Laser Power Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdmajorHighLPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.103
The value of this object provides the Major High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmajorLowLPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.104
The value of this object provides the Major Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorHighLPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.105
The value of this object provides the Minor High alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorLowLPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.106
The value of this object provides the Minor Low alarm value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdcurrentValueLPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.107
The value of this object provides the Current value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

oa100bdstateFlagLPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.108
The value of this object provides the state of the Laser Power Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdminValueLPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.109
The value of this object provides the minimum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmaxValueLPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.110
The value of this object provides the maximum value of the Laser Power Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdalarmStateLPSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.111
The value of this object provides the curent alarm state of the Laser Power Setting Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

oa100bdlabelCGSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.112
The value of this object provides the label of the Constant Gain Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bduomCGSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.113
The value of this object provides the Unit of Measure of the Constant Gain Setting Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdmajorHighCGSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.114
The value of this object provides the Major High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmajorLowCGSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.115
The value of this object provides the Major Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorHighCGSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.116
The value of this object provides the Minor High alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorLowCGSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.117
The value of this object provides the Minor Low alarm value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdcurrentValueCGSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.118
The value of this object provides the Current value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

oa100bdstateFlagCGSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.119
The value of this object provides the state of the Constant Gain Setting Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdminValueCGSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.120
The value of this object provides the minimum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmaxValueCGSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.121
The value of this object provides the maximum value of the Constant Gain Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdalarmStateCGSetting 1.3.6.1.4.1.1166.6.1.2.17.2.1.122
The value of this object provides the curent alarm state of the Constant Gain Setting Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

oa100bdlabelOptThreshold 1.3.6.1.4.1.1166.6.1.2.17.2.1.123
The value of this object provides the label of the Optical Input Threshold Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bduomOptThreshold 1.3.6.1.4.1.1166.6.1.2.17.2.1.124
The value of this object provides the Unit of Measure of the Optical Input Threshold Analog parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdmajorHighOptThreshold 1.3.6.1.4.1.1166.6.1.2.17.2.1.125
The value of this object provides the Major High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmajorLowOptThreshold 1.3.6.1.4.1.1166.6.1.2.17.2.1.126
The value of this object provides the Major Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorHighOptThreshold 1.3.6.1.4.1.1166.6.1.2.17.2.1.127
The value of this object provides the Minor High alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdminorLowOptThreshold 1.3.6.1.4.1.1166.6.1.2.17.2.1.128
The value of this object provides the Minor Low alarm value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdcurrentValueOptThreshold 1.3.6.1.4.1.1166.6.1.2.17.2.1.129
The value of this object provides the Current value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-write
OBJECT-TYPE    
  Float  

oa100bdstateFlagOptThreshold 1.3.6.1.4.1.1166.6.1.2.17.2.1.130
The value of this object provides the state of the Optical Input Threshold Analog parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdminValueOptThreshold 1.3.6.1.4.1.1166.6.1.2.17.2.1.131
The value of this object provides the minimum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdmaxValueOptThreshold 1.3.6.1.4.1.1166.6.1.2.17.2.1.132
The value of this object provides the maximum value of the Optical Input Threshold Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Float  

oa100bdalarmStateOptThreshold 1.3.6.1.4.1.1166.6.1.2.17.2.1.133
The value of this object provides the curent alarm state of the Optical Input Threshold Analog parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noAlarm(1), majorLowAlarm(2), minorLowAlarm(3), minorHighAlarm(4), majorHighAlarm(5), informational(6)  

gx2OA100BDDigitalTableIndex 1.3.6.1.4.1.1166.6.1.2.17.3.2.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

oa100bdlabelModeSetting 1.3.6.1.4.1.1166.6.1.2.17.3.2.2
The value of this object provides the label of the OA100BD's Mode Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdenumModeSetting 1.3.6.1.4.1.1166.6.1.2.17.3.2.3
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 0.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueModeSetting 1.3.6.1.4.1.1166.6.1.2.17.3.2.4
The value of this object is the current value of the parameter. It is an integer value from 0 to 5 representing the operation mode of the module.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER power-out-preset(1), power-out-set(2), laser-power-preset(3), laser-power-set(4), constant-gain-preset(5), constant-gain-set(6), invalid-mode(7)  

oa100bdstateFlagModeSetting 1.3.6.1.4.1.1166.6.1.2.17.3.2.5
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelModuleState 1.3.6.1.4.1.1166.6.1.2.17.3.2.6
The value of this object provides the label of the Module State Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdenumModuleState 1.3.6.1.4.1.1166.6.1.2.17.3.2.7
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueModuleState 1.3.6.1.4.1.1166.6.1.2.17.3.2.8
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

oa100bdstateFlagModuleState 1.3.6.1.4.1.1166.6.1.2.17.3.2.9
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelFactoryDefault 1.3.6.1.4.1.1166.6.1.2.17.3.2.10
The value of this object provides the label of the Factory Default Reset Digital parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdenumFactoryDefault 1.3.6.1.4.1.1166.6.1.2.17.3.2.11
The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueFactoryDefault 1.3.6.1.4.1.1166.6.1.2.17.3.2.12
The value of this object is the current value of the parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

oa100bdstateFlagFactoryDefault 1.3.6.1.4.1.1166.6.1.2.17.3.2.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2OA100BDStatusTableIndex 1.3.6.1.4.1.1166.6.1.2.17.4.3.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

oa100bdlabelBoot 1.3.6.1.4.1.1166.6.1.2.17.4.3.2
The value of this object provides the label of the Boot Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueBoot 1.3.6.1.4.1.1166.6.1.2.17.4.3.3
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagBoot 1.3.6.1.4.1.1166.6.1.2.17.4.3.4
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelFlash 1.3.6.1.4.1.1166.6.1.2.17.4.3.5
The value of this object provides the label of the Flash Status Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueFlash 1.3.6.1.4.1.1166.6.1.2.17.4.3.6
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagFlash 1.3.6.1.4.1.1166.6.1.2.17.4.3.7
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.17.4.3.8
The value of this object provides the label of the Factory Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.17.4.3.9
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagFactoryDataCRC 1.3.6.1.4.1.1166.6.1.2.17.4.3.10
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.17.4.3.11
The value of this object provides the label of the Alarm Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.17.4.3.12
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagAlarmDataCRC 1.3.6.1.4.1.1166.6.1.2.17.4.3.13
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.17.4.3.14
The value of this object provides the label of the Calibration Data CRC Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.17.4.3.15
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagCalibrationDataCRC 1.3.6.1.4.1.1166.6.1.2.17.4.3.16
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelOptInShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.17
The value of this object provides the label of the Optical Input Power Shutdown Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueOptInShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.18
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagOptInShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.19
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelMainTECTempShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.20
The value of this object provides the label of the Main TEC Temperature Shutdown Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueMainTECTempShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.21
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagMainTECTempShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.22
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelAuxTECTempShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.23
The value of this object provides the label of the Aux TEC Temperature Shutdown Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueAuxTECTempShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.24
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagAuxTECTempShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.25
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelPowerFail 1.3.6.1.4.1.1166.6.1.2.17.4.3.26
The value of this object provides the label of the Power Supply Fail Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvaluePowerFail 1.3.6.1.4.1.1166.6.1.2.17.4.3.27
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagPowerFail 1.3.6.1.4.1.1166.6.1.2.17.4.3.28
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelKeySwitch 1.3.6.1.4.1.1166.6.1.2.17.4.3.29
The value of this object provides the label of the Key Switch Setting Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueKeySwitch 1.3.6.1.4.1.1166.6.1.2.17.4.3.30
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagKeySwitch 1.3.6.1.4.1.1166.6.1.2.17.4.3.31
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelMainLaserCurrShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.32
The value of this object provides the label of the Main Laser Current Shutdown Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueMainLaserCurrShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.33
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagMainLaserCurrShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.34
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelAuxLaserCurrShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.35
The value of this object provides the label of the AuxLaser Current Shutdown Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueAuxLaserCurrShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.36
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagAuxLaserCurrShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.37
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelMainLaserPowShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.38
The value of this object provides the label of the Main Laser Power Shutdown Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueMainLaserPowShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.39
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagMainLaserPowShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.40
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelAuxLaserPowShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.41
The value of this object provides the label of the Aux Laser Power Shutdown Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueAuxLaserPowShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.42
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagAuxLaserPowShutdown 1.3.6.1.4.1.1166.6.1.2.17.4.3.43
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelADCStatus 1.3.6.1.4.1.1166.6.1.2.17.4.3.44
The value of this object provides the label of the ADC Operation Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueADCStatus 1.3.6.1.4.1.1166.6.1.2.17.4.3.45
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagADCStatus 1.3.6.1.4.1.1166.6.1.2.17.4.3.46
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelConstGainStatus 1.3.6.1.4.1.1166.6.1.2.17.4.3.47
The value of this object provides the label of the Constant Gain Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueConstGainStatus 1.3.6.1.4.1.1166.6.1.2.17.4.3.48
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagConstGainStatus 1.3.6.1.4.1.1166.6.1.2.17.4.3.49
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelHardwareErrorStatus 1.3.6.1.4.1.1166.6.1.2.17.4.3.50
The value of this object provides the label of the Hardware Error Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueHardwareErrorStatus 1.3.6.1.4.1.1166.6.1.2.17.4.3.51
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagHardwareErrorStatus 1.3.6.1.4.1.1166.6.1.2.17.4.3.52
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

oa100bdlabelStandbyStatus 1.3.6.1.4.1.1166.6.1.2.17.4.3.53
The value of this object provides the label of the Standby Status parameter.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdvalueStandbyStatus 1.3.6.1.4.1.1166.6.1.2.17.4.3.54
The value of this object provides the current state of the parameter (0-Ok, 1-Undetermined 2-Warning, 3-Minor, 4-Major, 5-Critical).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ok(1), undetermined(2), warning(3), minor(4), major(5), critical(6)  

oa100bdstateflagStandbyStatus 1.3.6.1.4.1.1166.6.1.2.17.4.3.55
The value of this object provides the state of the the parameter. (0-Hidden 1-Read-Only, 2-Updateable).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hidden(1), read-only(2), updateable(3)  

gx2OA100BDFactoryTableIndex 1.3.6.1.4.1.1166.6.1.2.17.5.4.1
The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

oa100bdbootControlByte 1.3.6.1.4.1.1166.6.1.2.17.5.4.2
The value of this object indicates which bank the firmware is currently being boot from. Boot Control Byte bit definition as follows : bit 0 : boot bit (0=boot from bank 0, 1=boot from bank 1) bit 1 : bank 0 status (0=bank is blank/bad, 1=bank is OK) bit 2 : bank 1 status (0=bank is blank/bad, 1=bank is OK) bits 3-7 : not used
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oa100bdbootStatusByte 1.3.6.1.4.1.1166.6.1.2.17.5.4.3
This object indicates the status of the last boot Boot Status Byte bit definitions as follows: bit 0 : bank 0 status (0=bank is OK or not used, 1=bank failed boot) bit 1 : bank 1 status (0=bank is OK or not used, 1=bank failed boot) bit 2 : active bank (0=bank 0 active, 1=bank 1 active) bits 3-7: not used
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oa100bdbank0CRC 1.3.6.1.4.1.1166.6.1.2.17.5.4.4
This object provides the CRC code of bank 0. The value is best displayed in Hex format
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oa100bdbank1CRC 1.3.6.1.4.1.1166.6.1.2.17.5.4.5
This object provides the CRC code of bank 1. The value is best displayed in Hex format
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oa100bdprgEEPROMByte 1.3.6.1.4.1.1166.6.1.2.17.5.4.6
This object indicates if the EEPROM has been programmed programmed EEPROM byte definitions as follows: 0xBB = EEPROM is programmed 0xDB = EEPROM is being restored to factory defaults 0xFF = EEPROM is blank any other values are assumed to be blank EEPROM
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oa100bdfactoryCRC 1.3.6.1.4.1.1166.6.1.2.17.5.4.7
This object provides the CRC code for the Factory data. The value is best displayed in Hex format
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oa100bdcalculateCRC 1.3.6.1.4.1.1166.6.1.2.17.5.4.8
This object indicates which of the Emnums will have the CRC calculated. Calculate CRC command defintions as follows : 0x00 : recalculate factory data CRC 0x01 : recalcualte calibration table CRC 0x02 : recalculate alarm data CRC other values not defined
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER factory(1), calibration(2), alarmdata(3)  

oa100bdhourMeter 1.3.6.1.4.1.1166.6.1.2.17.5.4.9
This object provides the hour meter reading of the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oa100bdflashPrgCntA 1.3.6.1.4.1.1166.6.1.2.17.5.4.10
This object provides the number of times the flash has been programmed on side A.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oa100bdflashPrgCntB 1.3.6.1.4.1.1166.6.1.2.17.5.4.11
This object provides the number of times the flash has been programmed on side B.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

oa100bdfwRev0 1.3.6.1.4.1.1166.6.1.2.17.5.4.12
This object provides the Revision of the firmware stores in bank 0. This value should be displayed as two ascii characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

oa100bdfwRev1 1.3.6.1.4.1.1166.6.1.2.17.5.4.13
This object provides the Revision of the firmware stores in bank 1. This value should be displayed as two ascii characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

gx2OA100BDHoldTimeTableIndex 1.3.6.1.4.1.1166.6.1.2.17.6.5.1
The value of this object is the index of the data object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2OA100BDHoldTimeSpecIndex 1.3.6.1.4.1.1166.6.1.2.17.6.5.2
The value of this object identifies the index of the alarm object to be modified.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4294967295  

gx2OA100BDHoldTimeData 1.3.6.1.4.1.1166.6.1.2.17.6.5.3
The value of this object provides access to the hold timers used to suppress nose on analog objects. This object is a 32 bit object. Validation data is entered into bytes zero and one of the object. Bytes three and four are used to entering the hold time for the specified alarm object. The Hold timer data ranges from 0 to 1300 seconds. The index of this object corresponds to the alarm object to be modified. Alarm Hold timers correspond to the index of this object as follows: Index 1 = xxx, index 2 = xxxx, Index 3 = xxxx, The hold time is represented in seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

trapOA100BDConfigChangeInteger 1
This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapOA100BDConfigChangeDisplayString 2
This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate'
TRAP-TYPE    

trapOA100BDModuleTemperatureAlarm 3
This trap is issued when the OA100B Module's Temperature goes out of range.
TRAP-TYPE    

trapOA100BDOpticalInPowerAlarm 4
This trap is issued when the input Optical Input Power parameter goes out of range.
TRAP-TYPE    

trapOA100BDOpticalOutPowerAlarm 5
This trap is issued when the input Optical Output Power parameter goes out of range.
TRAP-TYPE    

trapOA100BDMainTECTemperatureAlarm 6
This trap is issued when the OA100B Main TEC Temperature goes out of range.
TRAP-TYPE    

trapOA100BDMainLaserPowerAlarm 7
This trap is issued when the OA100B Main Laser Power goes out of range.
TRAP-TYPE    

trapOA100BDAuxTECTemperatureAlarm 8
This trap is issued when the OA100B Aux TEC Temperature goes out of range.
TRAP-TYPE    

trapOA100BDAuxLaserPowerAlarm 9
This trap is issued when the OA100B Aux Laser Power goes out of range.
TRAP-TYPE    

trapOA100BDFanCurrentAlarm 10
This trap is issued when the OA100B Module's Fan Currrent parameter goes out of range.
TRAP-TYPE    

trapOA100BDResetFacDefault 11
This trap is issued when the OA100B resets to factory defaults
TRAP-TYPE    

trapOA100BDStandbyMode 12
This trap is issued when the OA100B is in Standby Mode.
TRAP-TYPE    

trapOA100BDOptInShutdown 13
This trap is issued when the OA100B is in Optical Input Shutdown.
TRAP-TYPE    

trapOA100BDMainTECTempShutdown 14
This trap is issued when the OA100B is in Main TEC Temperature Shutdown.
TRAP-TYPE    

trapOA100BDAuxTECTempShutdown 15
This trap is issued when the OA100B is in Aux TEC Temperature Shutdown.
TRAP-TYPE    

trapOA100BDKeySwitch 16
This trap is issued when the Key Switch disables the OA100B.
TRAP-TYPE    

trapOA100BDPowerFail 17
This trap is issued when there is an OA100B Power Supply Failure.
TRAP-TYPE    

trapOA100BDMainLasCurrShutdown 18
This trap is issued when the OA100B is in Main Laser Current Shutdown.
TRAP-TYPE    

trapOA100BDAuxLasCurrShutdown 19
This trap is issued when the OA100B is in Aux Laser Current Shutdown.
TRAP-TYPE    

trapOA100BDMainLasPowerShutdown 20
This trap is issued when the OA100B is in Main Laser Power Shutdown.
TRAP-TYPE    

trapOA100BDAuxLasPowerShutdown 21
This trap is issued when the OA100B is in Aux Laser Power Shutdown.
TRAP-TYPE    

trapOA100BDInvalidMode 22
This trap is issued when the OA100B is in an invalid mode.
TRAP-TYPE    

trapOA100BDFlashAlarm 23
This trap is issued when the OA100B Module's boot or flash programming sequence has detected a Flash error.
TRAP-TYPE    

trapOA100BDBoot0Alarm 24
This trap is issued when the OA100B Module's Bank 0 Boot sequence has detected an error.
TRAP-TYPE    

trapOA100BDBoot1Alarm 25
This trap is issued when the OA100B Module's Bank 1 Boot sequence has detected an error.
TRAP-TYPE    

trapOA100BDAlarmDataCRCAlarm 26
This trap is issued when the OA100B Module detects an error calculating the alarm limit CRC.
TRAP-TYPE    

trapOA100BDFactoryDataCRCAlarm 27
This trap is issued when the OA100B Module detects an error calculating the Factory data CRC.
TRAP-TYPE    

trapOA100BDCalDataCRCAlarm 28
This trap is issued when the OA100B Module detects an error calculating the Calibration data CRC.
TRAP-TYPE    

trapOA100BDFacCalFloatAlarm 29
This trap is issued when the OA100B Module detects factory calibration float data alarm.
TRAP-TYPE    

trapOA100BDOptInThreshAlarm 30
This trap is issued when the OA100B Module Optical Input drops below the user set threshold.
TRAP-TYPE    

trapOA100BDGainErrorAlarm 31
This trap is issued when the OA100B Module can not produce the desired user set gain in Constant Gain Set Mode.
TRAP-TYPE    

trapOA100BDHardwareErrorAlarm 32
This trap is issued when any of the OA100BD Module's TEC,Laser, +12V, or +3.7V current parameters go out of range.
TRAP-TYPE