ONS15501-MIB

File: ONS15501-MIB.mib (43406 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
ENTITY-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
enterprises Integer32 Unsigned32
IpAddress TEXTUAL-CONVENTION DisplayString
TimeStamp DateAndTime MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP PhysicalIndex

Defined Types

Ons15501ImageDnLoadStatus  
The operational states for software image download. This enumerates all possible failure conditions.
TEXTUAL-CONVENTION    
  INTEGER notInitiated(1), inProgress(2), failedUnknownErr(3), failedFileNotFound(4), failedAccessDenied(5), failedTimedOut(6), completedSuccessfully(7), failedInDownload(8), failedTimeoutInDownload(9), failedToConnectToServer(10), failedWhileWritingToFlash(11), failedIllegalOperation(12), failedFileExists(13), failedUnknownTransferId(14), failedUnknownUser(15)  

Ons15501AdminStatus  
The Administrative state for a configured object.
TEXTUAL-CONVENTION    
  INTEGER disabled(1), enabled(2)  

Ons15501NTPStatus  
The operational state for NTP client. It may be 'unknown' if the NTP client has just started.
TEXTUAL-CONVENTION    
  INTEGER disabled(1), bothServersBad(2), usingPrimary(3), usingSecondary(4), unknown(5)  

Ons15501TenthVolt  
This data type represents voltage levels that are normally expressed in volts. Units are in tenths of a volt; for example, -48.1 volts will be represented as -481.
TEXTUAL-CONVENTION    
  Integer32 -1000..0  

Ons15501TenthdB  
This data type represents power levels (or power gain) that are normally expressed in dBm (dB). Units are in tenths of a dBm (db); for example, -5.1 dB will be represented as -51
TEXTUAL-CONVENTION    
  Integer32 -1000..500  

Ons15501TenthCentigrade  
This data type represents temperature values that are normally expressed in Centigrade. Units are in tenths of a Centigrade; for example, -5.1 Centigrade will be represented as -51.
TEXTUAL-CONVENTION    
  Integer32 -500..1000  

Ons15501AlarmStatus  
Represents a alarm level
TEXTUAL-CONVENTION    
  INTEGER critical(1), major(2), minor(3), info(4), noAlarm(5)  

Ons15501TrapTypeEnumeration  
This provides the details on type of alarm none - No exception unacceptableAmbientTemperature, - the temperature measured by thermal sensor shows value outside the operational limits. unacceptableElectricalPower, - the measured power supply level(s) are not within range. inputSignalPowerTooLow, - the measured input signal power is not within range. unacceptableOutputSignalPower, - the measured output signal power is not within range. embeddedControllerCommFailure, - the communication with embedded controller has failed. softwareUpgradeInitiated, - a TFTP/FTP request has been launched softwareUpgradeFailed, - a TFTP/FTP request that was launched has failed softwareUpgradeCompleted, - a TFTP/FTP request that was launched has completed softwareRebootInitiated, - a reboot has been requested on the unit softwareRolledBack, - the unit has booted from a bank that is not the programmed bank. This is possibly because the image from programmed bank was bad or because the boot loader was explicitly asked to boot from another bank (using the console). configurationChanged, - a writeable attribute has been modified (through any of the management interface exposed by the system - e.g. CLI. SNMP etc.) unacceptableGain, - equipment is unable to achieve the planned level for gain. laserPumpBad, - the measured parameters for the laser show that a laser pump has gone bad. eEPROMBad, - the writes / reads from EEPROM have problems.
TEXTUAL-CONVENTION    
  INTEGER unacceptableAmbientTemperature(1), unacceptableElectricalPower(2), inputSignalPowerTooLow(3), unacceptableOutputSignalPower(4), embeddedControllerCommFailure(5), softwareUpgradeInitiated(6), softwareUpgradeFailed(7), softwareUpgradeCompleted(8), softwareRebootInitiated(9), softwareRolledBack(10), configurationChanged(11), unacceptableGain(12), laserPumpBad(13), eEPROMBad(14), unknown(32767)  

Ons15501TrapDirectionEnumeration  
Represents a alarm level
TEXTUAL-CONVENTION    
  INTEGER dontCare(1), asserted(2), cleared(3)  

Ons15501TrapLogEntry  
SEQUENCE    
  ons15501TrapLogEntryIndex Unsigned32
  ons15501TrapLogEntryTrapType Ons15501TrapTypeEnumeration
  ons15501TrapLogEntryDirection Ons15501TrapDirectionEnumeration
  ons15501TrapLogEntryTimeStamp TimeStamp
  ons15501TrapLogEntryDateAndTime DateAndTime
  ons15501TrapLogEntryPhyIndex PhysicalIndex
  ons15501TrapLogEntrySeverity Ons15501AlarmStatus

Ons15501ActiveAlarmEntry  
SEQUENCE    
  ons15501ActAlarmType Ons15501TrapTypeEnumeration
  ons15501ActAlarmTimeStamp TimeStamp
  ons15501ActAlarmDateAndTime DateAndTime
  ons15501ActAlarmPhyIndex PhysicalIndex
  ons15501ActAlarmSeverity Ons15501AlarmStatus

Ons15501TrapDescriptionEntry  
SEQUENCE    
  ons15501TrapTypeValue Ons15501TrapTypeEnumeration
  ons15501TrapDescription DisplayString
  ons15501TrapSeverity Ons15501AlarmStatus

Defined Values

ons15501MIB 1.3.6.1.4.1.1869.11.11
The MIB definitions for ONS-15501 Optical Amplifier.
MODULE-IDENTITY    

synchronous 1.3.6.1.4.1.1869
OBJECT IDENTIFIER    

synEmbLx 1.3.6.1.4.1.1869.11
OBJECT IDENTIFIER    

ons15501Sys 1.3.6.1.4.1.1869.11.11.1
OBJECT IDENTIFIER    

ons15501Attr 1.3.6.1.4.1.1869.11.11.2
OBJECT IDENTIFIER    

ons15501Alarms 1.3.6.1.4.1.1869.11.11.3
OBJECT IDENTIFIER    

ons15501Notification 1.3.6.1.4.1.1869.11.11.4
OBJECT IDENTIFIER    

ons15501OIDs 1.3.6.1.4.1.1869.11.11.5
OBJECT IDENTIFIER    

ons15501MIBConformance 1.3.6.1.4.1.1869.11.11.6
OBJECT IDENTIFIER    

ons15501OIDSystem 1.3.6.1.4.1.1869.11.11.5.1
OBJECT IDENTIFIER    

ons15501OIDSystemAC 1.3.6.1.4.1.1869.11.11.5.3
OBJECT IDENTIFIER    

ons15501OIDEntity 1.3.6.1.4.1.1869.11.11.5.2
OBJECT IDENTIFIER    

ons15501OIDChasiss 1.3.6.1.4.1.1869.11.11.5.2.1
OBJECT IDENTIFIER    

ons15501OIDInPort 1.3.6.1.4.1.1869.11.11.5.2.2
OBJECT IDENTIFIER    

ons15501OIDOutPort 1.3.6.1.4.1.1869.11.11.5.2.3
OBJECT IDENTIFIER    

ons15501OIDPowerSupply 1.3.6.1.4.1.1869.11.11.5.2.4
OBJECT IDENTIFIER    

ons15501OIDChassisAC 1.3.6.1.4.1.1869.11.11.5.2.5
OBJECT IDENTIFIER    

ons15501OIDPowerSupplyAC 1.3.6.1.4.1.1869.11.11.5.2.6
OBJECT IDENTIFIER    

ons15501SysDevFlash1Image 1.3.6.1.4.1.1869.11.11.1.1
Gives the name of the software programmed on flash bank one.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ons15501SysDevFlash2Image 1.3.6.1.4.1.1869.11.11.1.2
Gives the name of the software programmed on flash bank two.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ons15501SysDevFlash3Image 1.3.6.1.4.1.1869.11.11.1.3
Gives the name of the software programmed on flash bank three.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ons15501SysSwDownload 1.3.6.1.4.1.1869.11.11.1.4
Used to control the image download to the flash banks. NOTE: Read on this attribute returns the last t/ftp command, without login/password. For s/w release 4.0 and above, the value read back includes the Kilo-Bytes downloaded for last download command. It is the size of file downloaded (in KB), if the download has completed. If a download is in progress this value would correspond to Kilo-Bytes successfully downloaded so far. For set the string syntax is one of the following a. abort - Aborts the current download b. ftp::::::[:passive] - Download image using ftp c. tftp::: - Download image using tftp where - is t/ftp server name - is login to be used for ftp (default anonymous) - password for the login name for ftp (default - no passwd - passwd is empty string) - path to be given on ftp prompt for cd (default - skip cd command ) - name of the file to be downloaded and burnt to the flash - NO DEFAULTS - because the filename is used as distinguishing versions there are no defaults for this command. For TFTP Path information is part of the filename - which flash has to be burnt [1|2|3] NOTE: Burn to active bank fails passive - if `passive` is specified, ftp is done using passive mode (provided for FTP download across firewall). NOTE: None of the fields should contain ':' within them, as it is used as field separator.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ons15501SysDevActiveImage 1.3.6.1.4.1.1869.11.11.1.5
Show currently active image's bank number. This may be different from ons15501SysConfiguredActiveImage, if a. The image on ons15501SysConfiguredActiveImage did not boot properly. b. User chose another bank during bootup, using the serial console port.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..3  

ons15501SysDeviceManagerList 1.3.6.1.4.1.1869.11.11.1.6
A ',' separated list of managers that will receive the Traps. If a specific host should receive the traps sent from this unit, it should be added to the list using CLI. Up to 16 managers can be present in this list.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ons15501SysSwDownloadStatus 1.3.6.1.4.1.1869.11.11.1.7
Denotes the FTP/TFTP status. Please refer to the description of Ons15501ImageDnLoadStatus for a list of supported values
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501ImageDnLoadStatus  

ons15501SysConfiguredImage 1.3.6.1.4.1.1869.11.11.1.8
Set/Show configured value for flash-bank number to be used on reboot. A set on this attribute will result in a reboot of the system. To restart the system, write back the same value as the one read from it (or from ons15501SysDevActiveImage).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..3  

ons15501CLEICode 1.3.6.1.4.1.1869.11.11.1.9
This attribute represents the CLEI (Common Language Equipment Identifier) code for the ONS15501.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ons15501PrimaryNTP 1.3.6.1.4.1.1869.11.11.1.10
The IP address for the primary NTP server.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

ons15501SecondaryNTP 1.3.6.1.4.1.1869.11.11.1.11
The IP address for the secondary NTP server.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

ons15501NTPAdminStatus 1.3.6.1.4.1.1869.11.11.1.12
The configured administrative status for NTP.
Status: current Access: read-write
OBJECT-TYPE    
  Ons15501AdminStatus  

ons15501NTPOperationalStatus 1.3.6.1.4.1.1869.11.11.1.13
The operational status for NTP.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501NTPStatus  

ons15501ActiveSoftwareVer 1.3.6.1.4.1.1869.11.11.1.14
This attribute provides the active software version. This will be same as the entPhysicalSoftwareRev for the entry corresponding to the chassis.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ons15501LastConfigChangeTime 1.3.6.1.4.1.1869.11.11.1.15
The value of sysUpTime when last configuration change was done. NMS may use this information to synchronize if some configuration has changed on the unit.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

ons15501InRemoteInfoUpdateTime 1.3.6.1.4.1.1869.11.11.1.16
This attribute gives the time-stamp when one or more of ons15501InRemoteChassisName, ons15501InRemotePortName, or ons15501InRemoteAgentIpAddr was changed. NMS may use this information to find the latest information if data from remote unit does not match that of this unit.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

ons15501InRemoteChassisName 1.3.6.1.4.1.1869.11.11.1.17
Manager initialized string value to identify the chassis associated with remote connection for optical input. ons15501InRemoteChassisName would be a ZERO length string if the input link is disabled. To disable the input link details set ons15501InRemoteChassisName to ZERO length string and ons15501InRemoteAgentIpAddr to 0.0.0.0.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ons15501InRemotePortName 1.3.6.1.4.1.1869.11.11.1.18
Manager initialized string value to identify the the port (on remote chassis) associated with remote connection for optical input. ons15501InRemotePortName would be a ZERO length string if the input link is disabled. To disable the input link details set ons15501InRemoteChassisName to ZERO length string and ons15501InRemoteAgentIpAddr to 0.0.0.0.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ons15501InRemoteAgentIpAddr 1.3.6.1.4.1.1869.11.11.1.19
Manager initialized string value to identify the network address to be used to reach the SNMP agent entity containing information about the port and chassis providing optical input. ons15501InRemoteAgentIpAddr would be a 0.0.0.0 if the input link is disabled. To disable the input link entry set ons15501InRemoteChassisName to ZERO length string and ons15501InRemoteAgentIpAddr to 0.0.0.0.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

ons15501OutRemoteInfoUpdateTime 1.3.6.1.4.1.1869.11.11.1.20
This attribute gives the time-stamp when one or more of ons15501OutRemoteChassisName, ons15501OutRemotePortName, or ons15501OutRemoteAgentIpAddr was changed. NMS may use this information to find the latest information if data from remote unit does not match that of this unit.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

ons15501OutRemoteChassisName 1.3.6.1.4.1.1869.11.11.1.21
Manager initialized string value to identify the chassis associated with remote connection for optical output. ons15501OutRemoteChassisName would be a ZERO length string if the output link is disabled. To disable the output link details set ons15501OutRemoteChassisName to ZERO length string and ons15501OutRemoteAgentIpAddr to 0.0.0.0.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ons15501OutRemotePortName 1.3.6.1.4.1.1869.11.11.1.22
Manager initialized string value to identify the the port (on remote chassis) associated with remote connection for optical output. ons15501OutRemotePortName would be a ZERO length string if the output link is disabled. To disable the output link details set ons15501OutRemoteChassisName to ZERO length string and ons15501OutRemoteAgentIpAddr to 0.0.0.0.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ons15501OutRemoteAgentIpAddr 1.3.6.1.4.1.1869.11.11.1.23
Manager initialized string value to identify the network address to be used to reach the SNMP agent entity containing information about the port and chassis using optical output. ons15501OutRemoteAgentIpAddr would be a 0.0.0.0 if the output link is disabled. To disable the output link entry set ons15501OutRemoteChassisName to ZERO length string and ons15501OutRemoteAgentIpAddr to 0.0.0.0.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

ons15501SysAlarmStatus 1.3.6.1.4.1.1869.11.11.1.24
Provides the highest severity alarm currently active.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501AlarmStatus  

ons15501SysDateAndTime 1.3.6.1.4.1.1869.11.11.1.25
The date and time of the System. The write will not succeed if the administrative state for NTP (ons15501NTPAdminStatus) is 'enabled'. Setting this attribute will autmatically change values for ons15501TrapLogEntryDateAndTime and ons15501ActAlarmDateAndTime.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

ons15501LastTrapIndex 1.3.6.1.4.1.1869.11.11.3.1
The value of ons15501TrapLogEntryIndex, used while logging the most recent trap. Goes back to 1, after reaching the max value. The trap log table is a circular list with the most recent entry at index given by this attribute. On restart of the unit, the value is reset to 1.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..32767  

ons15501TrapLogTable 1.3.6.1.4.1.1869.11.11.3.2
Table for last N traps (N = 100 in most cases). Please refer to ons15501LastTrapIndex for details on how this table is organized.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ons15501TrapLogEntry

ons15501TrapLogEntry 1.3.6.1.4.1.1869.11.11.3.2.1
Entry for a trap
Status: current Access: not-accessible
OBJECT-TYPE    
  Ons15501TrapLogEntry  

ons15501TrapLogEntryIndex 1.3.6.1.4.1.1869.11.11.3.2.1.1
index field for this entry. Actual range at run time is ons15501TrapCounter to ons15501TrapCounter - N + 1 or 1 (whichever is higher)
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..32767  

ons15501TrapLogEntryTrapType 1.3.6.1.4.1.1869.11.11.3.2.1.2
The type of trap. See the definition of Ons15501TrapTypeEnumeration for possible values.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501TrapTypeEnumeration  

ons15501TrapLogEntryDirection 1.3.6.1.4.1.1869.11.11.3.2.1.3
Whether the trap is being asserted or cleared. Please note that some traps don't have a direction. (e.g. configuration changed).
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501TrapDirectionEnumeration  

ons15501TrapLogEntryTimeStamp 1.3.6.1.4.1.1869.11.11.3.2.1.4
The value of sysUpTime when the entry was placed in the log.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

ons15501TrapLogEntryDateAndTime 1.3.6.1.4.1.1869.11.11.3.2.1.5
The local date and time at which the entry was placed in the log.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

ons15501TrapLogEntryPhyIndex 1.3.6.1.4.1.1869.11.11.3.2.1.6
Provides entPhysicalIndex value for the physical entity corresponding to the trap entry.
Status: current Access: read-only
OBJECT-TYPE    
  PhysicalIndex  

ons15501TrapLogEntrySeverity 1.3.6.1.4.1.1869.11.11.3.2.1.7
Provides the severity level corresponding to this trap entry.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501AlarmStatus  

ons15501ActiveAlarmTable 1.3.6.1.4.1.1869.11.11.3.3
Table for currently active alarm conditions. This table is effectively the list of traps that have been asserted but not cleared.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ons15501ActiveAlarmEntry

ons15501ActiveAlarmEntry 1.3.6.1.4.1.1869.11.11.3.3.1
Entry for an active alarm condition. For each alarm condition present on the equipment, there would be an entry in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ons15501ActiveAlarmEntry  

ons15501ActAlarmType 1.3.6.1.4.1.1869.11.11.3.3.1.1
Index field for ons15501ActiveAlarmTable. Presence of an entry implies that the specific alarm type is active on the unit.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ons15501TrapTypeEnumeration  

ons15501ActAlarmTimeStamp 1.3.6.1.4.1.1869.11.11.3.3.1.2
The time since when the alarm is active.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

ons15501ActAlarmDateAndTime 1.3.6.1.4.1.1869.11.11.3.3.1.3
The local date and time since when the alarm is active
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

ons15501ActAlarmPhyIndex 1.3.6.1.4.1.1869.11.11.3.3.1.4
Provides entPhysicalIndex value for the physical entity corresponding to the alarm entry.
Status: current Access: read-only
OBJECT-TYPE    
  PhysicalIndex  

ons15501ActAlarmSeverity 1.3.6.1.4.1.1869.11.11.3.3.1.5
Provides the severity level corresponding to this alarm entry.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501AlarmStatus  

ons15501TrapDescriptionTable 1.3.6.1.4.1.1869.11.11.3.4
Table for mapping the Ons15501TrapTypeEnumeration values to their textual information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ons15501TrapDescriptionEntry

ons15501TrapDescriptionEntry 1.3.6.1.4.1.1869.11.11.3.4.1
Entry for textual information about traps.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ons15501TrapDescriptionEntry  

ons15501TrapTypeValue 1.3.6.1.4.1.1869.11.11.3.4.1.1
Index field for this entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ons15501TrapTypeEnumeration  

ons15501TrapDescription 1.3.6.1.4.1.1869.11.11.3.4.1.2
The textual information corresponding to the ons15501TrapTypeValue.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ons15501TrapSeverity 1.3.6.1.4.1.1869.11.11.3.4.1.3
Provides the default severity level corresponding to the ons15501TrapTypeValue.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501AlarmStatus  

ons15501NotificationPrefix 1.3.6.1.4.1.1869.11.11.4.0
OBJECT IDENTIFIER    

ons15501GenericNotificationTrap 1.3.6.1.4.1.1869.11.11.4.0.1
This notification is generated whenever a bitmap change is observed on any of the monitored equipment, or when a change has to be notified.
Status: current Access: read-only
NOTIFICATION-TYPE    

ons15501InputOpticalPower 1.3.6.1.4.1.1869.11.11.2.1
The optical power being fed into the Amplifier.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501TenthdB  

ons15501InputOpticalPowerMean 1.3.6.1.4.1.1869.11.11.2.2
Mean value for input optical power. If the input optical power falls below the mean value by more than trigger (see ons15501InputOpticalPowerTrigger) an alarm is generated. The alarm is cleared when the input optical power is back within 90% of trigger from the mean.
Status: current Access: read-write
OBJECT-TYPE    
  Ons15501TenthdB -100..0  

ons15501InputOpticalPowerTrigger 1.3.6.1.4.1.1869.11.11.2.3
Trigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is generated, it is not cleared until the input optical power falls back within 90% of the trigger value from the mean. Please also refer to ons15501InputOpticalPowerMean above.
Status: current Access: read-write
OBJECT-TYPE    
  Ons15501TenthdB 0..200  

ons15501OutputOpticalPower 1.3.6.1.4.1.1869.11.11.2.4
The measured value for raw optical power being generated at the output of the Amplifier.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501TenthdB  

ons15501OutputSignalPower 1.3.6.1.4.1.1869.11.11.2.5
The optical signal power at the output of the Amplifier. The value of this attribute triggers the alarm, based on mean value and trigger as defined by ons15501OutputSignalPowerMean and ons15501OutputSignalPowerTrigger. This value is internally calculated using the following formula. ons15501OutputSignalPower = ons15501OpticalPowerGain + ons15501InputOpticalPower At very low ons15501InputOpticalPower (below -16 dBm), the ons15501OutputSignalPower has significant difference from ons15501OutputOpticalPower while at higher input power (ons15501InputOpticalPower) they are closer. Following graph captures the difference (for a 17 dBm EDFA) (dashes '-'/'_' denote optical output power while dots '.' denote signal output power) ^ | .- | .- | .- +5 dBm | .- | .- Optical | _.- power / | _ -. Signal |_ _ - . power | . | . | . -17 dBm +-----------------------+--------------> -29 dBm -10 dBm Input Optical Power
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501TenthdB  

ons15501OutputSignalPowerMean 1.3.6.1.4.1.1869.11.11.2.6
Mean value for output optical power. If the output signal power falls below (or goes above) the mean value by more than trigger (see ons15501OutputSignalPowerTrigger) an alarm is generated. The alarm is cleared when the output optical power is back within 90% of trigger from the mean.
Status: current Access: read-write
OBJECT-TYPE    
  Ons15501TenthdB -60..0  

ons15501OutputSignalPowerTrigger 1.3.6.1.4.1.1869.11.11.2.7
Trigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is generated, it is not cleared until the output signal power falls back within 90% of the trigger value from the mean. Please also refer to ons15501OutputSignalPowerMean above.
Status: current Access: read-write
OBJECT-TYPE    
  Ons15501TenthdB 0..180  

ons15501ConfigOpticalGain 1.3.6.1.4.1.1869.11.11.2.8
The configured value for power gain.
Status: current Access: read-write
OBJECT-TYPE    
  Ons15501TenthdB 70..175  

ons15501OpticalPowerGain 1.3.6.1.4.1.1869.11.11.2.9
The measured value for power gain. This value does not include the amplification noise that is significant for low input signals.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501TenthdB  

ons15501GainTrigger 1.3.6.1.4.1.1869.11.11.2.10
The gain deviation allowed from the configured gain before an alarm is asserted. The alarm is not cleared, until measured gain(ons15501OpticalPowerGain) is back within 90% of ons15501GainTrigger from configured gain (ons15501ConfigOpticalGain).
Status: current Access: read-write
OBJECT-TYPE    
  Ons15501TenthdB 0..20  

ons15501PowerSupply1Level 1.3.6.1.4.1.1869.11.11.2.11
The voltage fed through power supply 1. The value of the attribute is 10 times the the value in volts.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501TenthVolt  

ons15501PowerSupply2Level 1.3.6.1.4.1.1869.11.11.2.12
The voltage fed through power supply 2. The value of the attribute is 10 times the the value in volts.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501TenthVolt  

ons15501LaserStatus 1.3.6.1.4.1.1869.11.11.2.13
Gives the status of the laser pumps.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501AlarmStatus  

ons15501DevAmbTemp 1.3.6.1.4.1.1869.11.11.2.14
The ambient temperature for the device.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501TenthCentigrade  

ons15501DevAmbTempMean 1.3.6.1.4.1.1869.11.11.2.15
Mean value for temperature. If the temperature falls below (or goes above) the mean value by more than trigger level (see ons15501DevAmbTempTrigger) an alarm is generated. The alarm is cleared when the temperature is back within 90% of trigger value, from the mean.
Status: current Access: read-write
OBJECT-TYPE    
  Ons15501TenthCentigrade 200..400  

ons15501DevAmbTempTrigger 1.3.6.1.4.1.1869.11.11.2.16
Please refer to ons15501DevAmbTempMean above. Trigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is generated, it is not cleared until the temperature falls back within 90% of the value.
Status: current Access: read-write
OBJECT-TYPE    
  Ons15501TenthCentigrade 200..300  

ons15501PowerSupply1Status 1.3.6.1.4.1.1869.11.11.2.17
Gives the status of power supply one.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501AlarmStatus  

ons15501PowerSupply2Status 1.3.6.1.4.1.1869.11.11.2.18
Gives the status of power supply two.
Status: current Access: read-only
OBJECT-TYPE    
  Ons15501AlarmStatus  

ons15501MIBCompliances 1.3.6.1.4.1.1869.11.11.6.1
OBJECT IDENTIFIER    

ons15501MIBGroups 1.3.6.1.4.1.1869.11.11.6.2
OBJECT IDENTIFIER    

ons15501FinalCompliance 1.3.6.1.4.1.1869.11.11.6.1.1
The compliance statement for final release ONS15501.
Status: deprecated Access: read-only
MODULE-COMPLIANCE    

ons15501Rel4Compliance 1.3.6.1.4.1.1869.11.11.6.1.2
The compliance statement for 4.0 release ONS15501.
Status: current Access: read-only
MODULE-COMPLIANCE    

ons15501SysInfoGroup 1.3.6.1.4.1.1869.11.11.6.2.1
The basic group defines objects which are common to all Embedded Linux product series of Synchronous equipment.
Status: deprecated Access: read-only
OBJECT-GROUP    

ons15501TrapLogGroup 1.3.6.1.4.1.1869.11.11.6.2.2
The trap attribute group provides the trap logs. These attributes are also used in trap notifications.
Status: current Access: read-only
OBJECT-GROUP    

ons15501ActiveAlarmGroup 1.3.6.1.4.1.1869.11.11.6.2.3
The alarm attribute group provides the list of active alarms
Status: current Access: read-only
OBJECT-GROUP    

ons15501TrapDescriptionGroup 1.3.6.1.4.1.1869.11.11.6.2.4
The trap description attribute group provides the mapping from trap type to textual information about the trap.
Status: current Access: read-only
OBJECT-GROUP    

ons15501FinalAttrGroup 1.3.6.1.4.1.1869.11.11.6.2.5
The ons15501 group of attributes models the parameters in the EDFA.
Status: deprecated Access: read-only
OBJECT-GROUP    

ons15501FinalNotificationsGroup 1.3.6.1.4.1.1869.11.11.6.2.6
The notification that carries all the exception information.
Status: current Access: read-only
NOTIFICATION-GROUP    

ons15501CoreAttrGroup 1.3.6.1.4.1.1869.11.11.6.2.7
The ons15501 group of attributes models the parameters in the EDFA. The power supply related attributes are not part of this group.
Status: current Access: read-only
OBJECT-GROUP    

ons15501PowerSupplyStatusGroup 1.3.6.1.4.1.1869.11.11.6.2.8
The ons15501 group of attributes models the status of power supplies. The support for status was introduced in version 4.0.
Status: current Access: read-only
OBJECT-GROUP    

ons15501PowerSupplyLevelGroup 1.3.6.1.4.1.1869.11.11.6.2.9
The ons15501 group of attributes provides the voltage level of power supplies. It is available only for DC series of ONS15501.
Status: current Access: read-only
OBJECT-GROUP    

ons15501SysInfoGroup2 1.3.6.1.4.1.1869.11.11.6.2.10
The basic group defines objects which are common to all Embedded Linux product series of Synchronous equipment.
Status: current Access: read-only
OBJECT-GROUP