OTN-MIB

File: OTN-MIB.mib (113786 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMP-FRAMEWORK-MIB
SNMPv2-CONF IF-MIB PerfHist-TC-MIB
OPT-IF-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Gauge32 Integer32 Unsigned32
transmission TruthValue SnmpAdminString
MODULE-COMPLIANCE OBJECT-GROUP ifIndex
PerfCurrentCount PerfIntervalCount optIfODUkTConfigEntry

Defined Types

IntervalNumber  
Uniquely identifies a 15 minute interval. The interval identified by 1 is the most recently completed interval, and the interval identified by n is the interval immediately preceding the one identified by n-1.
TEXTUAL-CONVENTION    
  Integer32 1..96  

OptIfPerfMonIntervalEntry  
SEQUENCE    
  optIfPerfMonIntervalNumIntervals Unsigned32
  optIfPerfMonIntervalNumInvalidIntervals Unsigned32

OptIfOTSnConfigEntry  
SEQUENCE    
  optIfOTSnTraceIdentifierTransmitted SnmpAdminString
  optIfOTSnDAPIExpected SnmpAdminString
  optIfOTSnSAPIExpected SnmpAdminString
  optIfOTSnTraceIdentifierAccepted SnmpAdminString
  optIfOTSnAcTIStatus INTEGER
  optIfOTSnTIMDetMode INTEGER
  optIfOTSnTIMActEnabled TruthValue
  optIfOTSnCurrentStatus INTEGER

OptIfOTSnSinkCurrentEntry  
SEQUENCE    
  optIfOTSnSinkCurrentSuspectedFlag TruthValue
  optIfOTSnSinkCurrentInputPower Integer32
  optIfOTSnSinkCurrentLowInputPower Integer32
  optIfOTSnSinkCurrentHighInputPower Integer32
  optIfOTSnSinkCurrentLowerInputPowerThreshold Integer32
  optIfOTSnSinkCurrentUpperInputPowerThreshold Integer32

OptIfOTSnSinkIntervalEntry  
SEQUENCE    
  optIfOTSnSinkIntervalNumber IntervalNumber
  optIfOTSnSinkIntervalSuspectedFlag TruthValue
  optIfOTSnSinkIntervalLastInputPower Integer32
  optIfOTSnSinkIntervalLowInputPower Integer32
  optIfOTSnSinkIntervalHighInputPower Integer32

OptIfOTSnSinkCurDayEntry  
SEQUENCE    
  optIfOTSnSinkCurDaySuspectedFlag TruthValue
  optIfOTSnSinkCurDayLowInputPower Integer32
  optIfOTSnSinkCurDayHighInputPower Integer32

OptIfOTSnSinkPrevDayEntry  
SEQUENCE    
  optIfOTSnSinkPrevDaySuspectedFlag TruthValue
  optIfOTSnSinkPrevDayLastInputPower Integer32
  optIfOTSnSinkPrevDayLowInputPower Integer32
  optIfOTSnSinkPrevDayHighInputPower Integer32

OptIfOTSnSrcCurrentEntry  
SEQUENCE    
  optIfOTSnSrcCurrentSuspectedFlag TruthValue
  optIfOTSnSrcCurrentOutputPower Integer32
  optIfOTSnSrcCurrentLowOutputPower Integer32
  optIfOTSnSrcCurrentHighOutputPower Integer32
  optIfOTSnSrcCurrentLowerOutputPowerThreshold Integer32
  optIfOTSnSrcCurrentUpperOutputPowerThreshold Integer32
  optIfOTSnSrcCurrentLaserTemp Integer32
  optIfOTSnSrcCurrentLowLaserTemp Integer32
  optIfOTSnSrcCurrentHighLaserTemp Integer32
  optIfOTSnSrcCurrentLowerLaserTempThreshold Integer32
  optIfOTSnSrcCurrentUpperLaserTempThreshold Integer32

OptIfOTSnSrcIntervalEntry  
SEQUENCE    
  optIfOTSnSrcIntervalNumber IntervalNumber
  optIfOTSnSrcIntervalSuspectedFlag TruthValue
  optIfOTSnSrcIntervalLastOutputPower Integer32
  optIfOTSnSrcIntervalLowOutputPower Integer32
  optIfOTSnSrcIntervalHighOutputPower Integer32
  optIfOTSnSrcIntervalLastLaserTemp Integer32
  optIfOTSnSrcIntervalLowLaserTemp Integer32
  optIfOTSnSrcIntervalHighLaserTemp Integer32

OptIfOTSnSrcCurDayEntry  
SEQUENCE    
  optIfOTSnSrcCurDaySuspectedFlag TruthValue
  optIfOTSnSrcCurDayLowOutputPower Integer32
  optIfOTSnSrcCurDayHighOutputPower Integer32
  optIfOTSnSrcCurDayLowLaserTemp Integer32
  optIfOTSnSrcCurDayHighLaserTemp Integer32

OptIfOTSnSrcPrevDayEntry  
SEQUENCE    
  optIfOTSnSrcPrevDaySuspectedFlag TruthValue
  optIfOTSnSrcPrevDayLastOutputPower Integer32
  optIfOTSnSrcPrevDayLowOutputPower Integer32
  optIfOTSnSrcPrevDayHighOutputPower Integer32
  optIfOTSnSrcPrevDayLastLaserTemp Integer32
  optIfOTSnSrcPrevDayLowLaserTemp Integer32
  optIfOTSnSrcPrevDayHighLaserTemp Integer32

OptIfOMSnConfigEntry  
SEQUENCE    
  optIfOMSnOrder Unsigned32
  optIfOMSnCurrentStatus INTEGER

OptIfOMSnSinkCurrentEntry  
SEQUENCE    
  optIfOMSnSinkCurrentSuspectedFlag TruthValue
  optIfOMSnSinkCurrentAggregatedInputPower Integer32
  optIfOMSnSinkCurrentLowAggregatedInputPower Integer32
  optIfOMSnSinkCurrentHighAggregatedInputPower Integer32
  optIfOMSnSinkCurrentLowerInputPowerThreshold Integer32
  optIfOMSnSinkCurrentUpperInputPowerThreshold Integer32
  optIfOMSnSinkCurrentLaserTemp Integer32
  optIfOMSnSinkCurrentLowLaserTemp Integer32
  optIfOMSnSinkCurrentHighLaserTemp Integer32
  optIfOMSnSinkCurrentLowerLaserTempThreshold Integer32
  optIfOMSnSinkCurrentUpperLaserTempThreshold Integer32

OptIfOMSnSinkIntervalEntry  
SEQUENCE    
  optIfOMSnSinkIntervalNumber IntervalNumber
  optIfOMSnSinkIntervalSuspectedFlag TruthValue
  optIfOMSnSinkIntervalLastAggregatedInputPower Integer32
  optIfOMSnSinkIntervalLowAggregatedInputPower Integer32
  optIfOMSnSinkIntervalHighAggregatedInputPower Integer32
  optIfOMSnSinkIntervalLastLaserTemp Integer32
  optIfOMSnSinkIntervalLowLaserTemp Integer32
  optIfOMSnSinkIntervalHighLaserTemp Integer32

OptIfOMSnSinkCurDayEntry  
SEQUENCE    
  optIfOMSnSinkCurDaySuspectedFlag TruthValue
  optIfOMSnSinkCurDayLowAggregatedInputPower Integer32
  optIfOMSnSinkCurDayHighAggregatedInputPower Integer32
  optIfOMSnSinkCurDayLowLaserTemp Integer32
  optIfOMSnSinkCurDayHighLaserTemp Integer32

OptIfOMSnSinkPrevDayEntry  
SEQUENCE    
  optIfOMSnSinkPrevDaySuspectedFlag TruthValue
  optIfOMSnSinkPrevDayLastAggregatedInputPower Integer32
  optIfOMSnSinkPrevDayLowAggregatedInputPower Integer32
  optIfOMSnSinkPrevDayHighAggregatedInputPower Integer32
  optIfOMSnSinkPrevDayLastLaserTemp Integer32
  optIfOMSnSinkPrevDayLowLaserTemp Integer32
  optIfOMSnSinkPrevDayHighLaserTemp Integer32

OptIfOMSnSrcCurrentEntry  
SEQUENCE    
  optIfOMSnSrcCurrentSuspectedFlag TruthValue
  optIfOMSnSrcCurrentOutputPower Integer32
  optIfOMSnSrcCurrentLowOutputPower Integer32
  optIfOMSnSrcCurrentHighOutputPower Integer32
  optIfOMSnSrcCurrentLowerOutputPowerThreshold Integer32
  optIfOMSnSrcCurrentUpperOutputPowerThreshold Integer32
  optIfOMSnSrcCurrentLaserTemp Integer32
  optIfOMSnSrcCurrentLowLaserTemp Integer32
  optIfOMSnSrcCurrentHighLaserTemp Integer32
  optIfOMSnSrcCurrentLowerLaserTempThreshold Integer32
  optIfOMSnSrcCurrentUpperLaserTempThreshold Integer32

OptIfOMSnSrcIntervalEntry  
SEQUENCE    
  optIfOMSnSrcIntervalNumber IntervalNumber
  optIfOMSnSrcIntervalSuspectedFlag TruthValue
  optIfOMSnSrcIntervalLastOutputPower Integer32
  optIfOMSnSrcIntervalLowOutputPower Integer32
  optIfOMSnSrcIntervalHighOutputPower Integer32
  optIfOMSnSrcIntervalLastLaserTemp Integer32
  optIfOMSnSrcIntervalLowLaserTemp Integer32
  optIfOMSnSrcIntervalHighLaserTemp Integer32

OptIfOMSnSrcCurDayEntry  
SEQUENCE    
  optIfOMSnSrcCurDaySuspectedFlag TruthValue
  optIfOMSnSrcCurDayLowOutputPower Integer32
  optIfOMSnSrcCurDayHighOutputPower Integer32
  optIfOMSnSrcCurDayLowLaserTemp Integer32
  optIfOMSnSrcCurDayHighLaserTemp Integer32

OptIfOMSnSrcPrevDayEntry  
SEQUENCE    
  optIfOMSnSrcPrevDaySuspectedFlag TruthValue
  optIfOMSnSrcPrevDayLastOutputPower Integer32
  optIfOMSnSrcPrevDayLowOutputPower Integer32
  optIfOMSnSrcPrevDayHighOutputPower Integer32
  optIfOMSnSrcPrevDayLastLaserTemp Integer32
  optIfOMSnSrcPrevDayLowLaserTemp Integer32
  optIfOMSnSrcPrevDayHighLaserTemp Integer32

OptIfOChConfigEntry  
SEQUENCE    
  optIfOChSinkAdaptActive TruthValue
  optIfOChSourceAdaptActive TruthValue
  optIfOChSinkFECEnabled TruthValue
  optIfOChCurrentStatus INTEGER

OptIfOChSinkCurrentEntry  
SEQUENCE    
  optIfOChSinkCurrentSuspectedFlag TruthValue
  optIfOChSinkCurrentInputPower Integer32
  optIfOChSinkCurrentLowInputPower Integer32
  optIfOChSinkCurrentHighInputPower Integer32
  optIfOChSinkCurrentLowerInputPowerThreshold Integer32
  optIfOChSinkCurrentUpperInputPowerThreshold Integer32

OptIfOChSinkIntervalEntry  
SEQUENCE    
  optIfOChSinkIntervalNumber IntervalNumber
  optIfOChSinkIntervalSuspectedFlag TruthValue
  optIfOChSinkIntervalLastInputPower Integer32
  optIfOChSinkIntervalLowInputPower Integer32
  optIfOChSinkIntervalHighInputPower Integer32

OptIfOChSinkCurDayEntry  
SEQUENCE    
  optIfOChSinkCurDaySuspectedFlag TruthValue
  optIfOChSinkCurDayLowInputPower Integer32
  optIfOChSinkCurDayHighInputPower Integer32

OptIfOChSinkPrevDayEntry  
SEQUENCE    
  optIfOChSinkPrevDaySuspectedFlag TruthValue
  optIfOChSinkPrevDayLastInputPower Integer32
  optIfOChSinkPrevDayLowInputPower Integer32
  optIfOChSinkPrevDayHighInputPower Integer32

OptIfOChSrcCurrentEntry  
SEQUENCE    
  optIfOChSrcCurrentSuspectedFlag TruthValue
  optIfOChSrcCurrentOutputPower Integer32
  optIfOChSrcCurrentLowOutputPower Integer32
  optIfOChSrcCurrentHighOutputPower Integer32
  optIfOChSrcCurrentLowerOutputPowerThreshold Integer32
  optIfOChSrcCurrentUpperOutputPowerThreshold Integer32
  optIfOChSrcCurrentLaserTemp Integer32
  optIfOChSrcCurrentLowLaserTemp Integer32
  optIfOChSrcCurrentHighLaserTemp Integer32
  optIfOChSrcCurrentLowerLaserTempThreshold Integer32
  optIfOChSrcCurrentUpperLaserTempThreshold Integer32

OptIfOChSrcIntervalEntry  
SEQUENCE    
  optIfOChSrcIntervalNumber IntervalNumber
  optIfOChSrcIntervalSuspectedFlag TruthValue
  optIfOChSrcIntervalLastOutputPower Integer32
  optIfOChSrcIntervalLowOutputPower Integer32
  optIfOChSrcIntervalHighOutputPower Integer32
  optIfOChSrcIntervalLastLaserTemp Integer32
  optIfOChSrcIntervalLowLaserTemp Integer32
  optIfOChSrcIntervalHighLaserTemp Integer32

OptIfOChSrcCurDayEntry  
SEQUENCE    
  optIfOChSrcCurDaySuspectedFlag TruthValue
  optIfOChSrcCurDayLowOutputPower Integer32
  optIfOChSrcCurDayHighOutputPower Integer32
  optIfOChSrcCurDayLowLaserTemp Integer32
  optIfOChSrcCurDayHighLaserTemp Integer32

OptIfOChSrcPrevDayEntry  
SEQUENCE    
  optIfOChSrcPrevDaySuspectedFlag TruthValue
  optIfOChSrcPrevDayLastOutputPower Integer32
  optIfOChSrcPrevDayLowOutputPower Integer32
  optIfOChSrcPrevDayHighOutputPower Integer32
  optIfOChSrcPrevDayLastLaserTemp Integer32
  optIfOChSrcPrevDayLowLaserTemp Integer32
  optIfOChSrcPrevDayHighLaserTemp Integer32

OptIfOTUkConfigEntry  
SEQUENCE    
  optIfOTUkTraceIdentifierTransmitted SnmpAdminString
  optIfOTUkDAPIExpected SnmpAdminString
  optIfOTUkSAPIExpected SnmpAdminString
  optIfOTUkTraceIdentifierAccepted SnmpAdminString
  optIfOTUkAcTIStatus INTEGER
  optIfOTUkTIMDetMode INTEGER
  optIfOTUkTIMActEnabled TruthValue
  optIfOTUkDEGThr INTEGER
  optIfOTUkDEGM INTEGER
  optIfOTUkCurrentStatus INTEGER

OptIfODUkTSinkConfigEntry  
SEQUENCE    
  optIfODUkTTcmId Unsigned32
  optIfODUkTDAPIExpected SnmpAdminString
  optIfODUkTSAPIExpected SnmpAdminString
  optIfODUkTTraceIdentifierAccepted SnmpAdminString
  optIfODUkTAcTIStatus INTEGER
  optIfODUkTTIMDetMode INTEGER
  optIfODUkTTIMActEnabled TruthValue
  optIfODUkTDEGThr INTEGER
  optIfODUkTDEGM INTEGER
  optIfODUkTSinkMode INTEGER
  optIfODUkTSinkLockSignalAdminState INTEGER
  optIfODUkTCurrentStatus INTEGER

OptIfODUkTSourceConfigEntry  
SEQUENCE    
  optIfODUkTTcmId Unsigned32
  optIfODUkTTraceIdentifierTransmitted SnmpAdminString
  optIfODUkTSourceMode INTEGER
  optIfODUkTSourceLockSignalAdminState INTEGER

OptIfODUkPConfigEntry  
SEQUENCE    
  optIfODUkPTraceIdentifierTransmitted SnmpAdminString
  optIfODUkPDAPIExpected SnmpAdminString
  optIfODUkPSAPIExpected SnmpAdminString
  optIfODUkPTraceIdentifierAccepted SnmpAdminString
  optIfODUkPAcTIStatus INTEGER
  optIfODUkPTIMDetMode INTEGER
  optIfODUkPTIMActEnabled TruthValue
  optIfODUkPDEGThr INTEGER
  optIfODUkPDEGM INTEGER
  optIfODUkPCurrentStatus INTEGER
  optIfODUkPPayloadTypeTransmitted Unsigned32
  optIfODUkPPayloadTypeExpected Unsigned32
  optIfODUkPPayloadTypeAccepted Unsigned32
  optIfODUkPActiveAdaptFuncSource INTEGER
  optIfODUkPActiveAdaptFuncSink INTEGER

Defined Values

optIfMibModule 1.3.6.1.2.1.10.1
The draft MIB module to describe OTN interfaces objects.
MODULE-IDENTITY    

optIfObjects 1.3.6.1.2.1.10.1.1
OBJECT IDENTIFIER    

optIfConfs 1.3.6.1.2.1.10.1.2
OBJECT IDENTIFIER    

optIfPerfMon 1.3.6.1.2.1.10.1.1.1
OBJECT IDENTIFIER    

optIfOTSn 1.3.6.1.2.1.10.1.1.2
OBJECT IDENTIFIER    

optIfOMSn 1.3.6.1.2.1.10.1.1.3
OBJECT IDENTIFIER    

optIfOCh 1.3.6.1.2.1.10.1.1.4
OBJECT IDENTIFIER    

optIfOTUk 1.3.6.1.2.1.10.1.1.4.1
OBJECT IDENTIFIER    

optIfODUkT 1.3.6.1.2.1.10.1.1.4.2
OBJECT IDENTIFIER    

optIfODUkP 1.3.6.1.2.1.10.1.1.4.3
OBJECT IDENTIFIER    

optIfGroups 1.3.6.1.2.1.10.1.2.1
OBJECT IDENTIFIER    

optIfCompl 1.3.6.1.2.1.10.1.2.2
OBJECT IDENTIFIER    

optIfPerfMonCurrentTimeElapsed 1.3.6.1.2.1.10.1.1.1.1
Number of seconds elapsed in the current 15 minute performance monitoring interval.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..900  

optIfPerfMonCurDayTimeElapsed 1.3.6.1.2.1.10.1.1.1.2
Number of seconds elapsed in the current calendar day performance monitoring period.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..86400  

optIfPerfMonIntervalTable 1.3.6.1.2.1.10.1.1.1.3
A table of 15 minute performance monitoring interval information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfPerfMonIntervalEntry

optIfPerfMonIntervalEntry 1.3.6.1.2.1.10.1.1.1.3.1
A conceptual row that contains 15 minute performance monitoring interval information of an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfPerfMonIntervalEntry  

optIfPerfMonIntervalNumIntervals 1.3.6.1.2.1.10.1.1.1.3.1.1
The number of 15 minute intervals for which performance monitoring data is available. The number is the same for all the associated sub layers of the interface. An optical interface must be capable of supporting at least n intervals, where n is defined as follows: The minimum value of n is 4. The default of n is 32. The maximum value of n is 96. The value of this object will be n unless performance monitoring was (re-)started for the interface within the last (n*15) minutes, in which case the value will be the number of complete 15 minute intervals since measurement was (re-)started.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..96  

optIfPerfMonIntervalNumInvalidIntervals 1.3.6.1.2.1.10.1.1.1.3.1.2
The number of intervals in the range from 0 to optIfPerfMonIntervalNumIntervals for which no performance monitoring data is available and/or the data is invalid.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..96  

optIfOTSnConfigTable 1.3.6.1.2.1.10.1.1.2.1
A table of OTSn configuration information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOTSnConfigEntry

optIfOTSnConfigEntry 1.3.6.1.2.1.10.1.1.2.1.1
A conceptual row that contains OTSn configuration information of an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOTSnConfigEntry  

optIfOTSnTraceIdentifierTransmitted 1.3.6.1.2.1.10.1.1.2.1.1.1
The trace identifier transmitted.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..64)  

optIfOTSnDAPIExpected 1.3.6.1.2.1.10.1.1.2.1.1.2
The DAPI expected by the receiver.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..16)  

optIfOTSnSAPIExpected 1.3.6.1.2.1.10.1.1.2.1.1.3
The SAPI expected by the receiver.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..16)  

optIfOTSnTraceIdentifierAccepted 1.3.6.1.2.1.10.1.1.2.1.1.4
The actual trace identifier received.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..64)  

optIfOTSnAcTIStatus 1.3.6.1.2.1.10.1.1.2.1.1.5
The status of the accepted Trail Trace Identifier by the receiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stable(1), unstable(2)  

optIfOTSnTIMDetMode 1.3.6.1.2.1.10.1.1.2.1.1.6
Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), dapi(2), sapi(3), both(4)  

optIfOTSnTIMActEnabled 1.3.6.1.2.1.10.1.1.2.1.1.7
Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

optIfOTSnCurrentStatus 1.3.6.1.2.1.10.1.1.2.1.1.8
Indicates the failure condition of the entity, if any.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noDefect(1), bdiP(2), bdiO(3), bdi(4), tim(5), losP(6), losO(7), los(8)  

optIfOTSnSinkCurrentTable 1.3.6.1.2.1.10.1.1.2.2
A table of OTSn sink performance monitoring information for the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOTSnSinkCurrentEntry

optIfOTSnSinkCurrentEntry 1.3.6.1.2.1.10.1.1.2.2.1
A conceptual row that contains OTSn sink performance monitoring information of an interface for the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOTSnSinkCurrentEntry  

optIfOTSnSinkCurrentSuspectedFlag 1.3.6.1.2.1.10.1.1.2.2.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOTSnSinkCurrentInputPower 1.3.6.1.2.1.10.1.1.2.2.1.2
The optical power monitored at the input.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSinkCurrentLowInputPower 1.3.6.1.2.1.10.1.1.2.2.1.3
The lowest optical power monitored at the input during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSinkCurrentHighInputPower 1.3.6.1.2.1.10.1.1.2.2.1.4
The highest optical power monitored at the input during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSinkCurrentLowerInputPowerThreshold 1.3.6.1.2.1.10.1.1.2.2.1.5
The lower limit threshold on input power. If optIfOTSnSinkCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOTSnSinkCurrentUpperInputPowerThreshold 1.3.6.1.2.1.10.1.1.2.2.1.6
The upper limit threshold on input power. If optIfOTSnSinkCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOTSnSinkIntervalTable 1.3.6.1.2.1.10.1.1.2.3
A table of historical OTSn sink performance monitoring information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOTSnSinkIntervalEntry

optIfOTSnSinkIntervalEntry 1.3.6.1.2.1.10.1.1.2.3.1
A conceptual row that contains OTSn sink performance monitoring information of an interface during a particular historical interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOTSnSinkIntervalEntry  

optIfOTSnSinkIntervalNumber 1.3.6.1.2.1.10.1.1.2.3.1.1
Uniquely identifies the interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntervalNumber  

optIfOTSnSinkIntervalSuspectedFlag 1.3.6.1.2.1.10.1.1.2.3.1.2
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOTSnSinkIntervalLastInputPower 1.3.6.1.2.1.10.1.1.2.3.1.3
The last optical power monitored at the input during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSinkIntervalLowInputPower 1.3.6.1.2.1.10.1.1.2.3.1.4
The lowest optical power monitored at the input during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSinkIntervalHighInputPower 1.3.6.1.2.1.10.1.1.2.3.1.5
The highest optical power monitored at the input during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSinkCurDayTable 1.3.6.1.2.1.10.1.1.2.4
A table of OTSn sink performance monitoring information for the current calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOTSnSinkCurDayEntry

optIfOTSnSinkCurDayEntry 1.3.6.1.2.1.10.1.1.2.4.1
A conceptual row that contains OTSn sink performance monitoring information of an interface for the current calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOTSnSinkCurDayEntry  

optIfOTSnSinkCurDaySuspectedFlag 1.3.6.1.2.1.10.1.1.2.4.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOTSnSinkCurDayLowInputPower 1.3.6.1.2.1.10.1.1.2.4.1.2
The lowest optical power monitored at the input during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSinkCurDayHighInputPower 1.3.6.1.2.1.10.1.1.2.4.1.3
The highest optical power monitored at the input during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSinkPrevDayTable 1.3.6.1.2.1.10.1.1.2.5
A table of OTSn sink performance monitoring information for the previous calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOTSnSinkPrevDayEntry

optIfOTSnSinkPrevDayEntry 1.3.6.1.2.1.10.1.1.2.5.1
A conceptual row that contains OTSn sink performance monitoring information of an interface for the previous calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOTSnSinkPrevDayEntry  

optIfOTSnSinkPrevDaySuspectedFlag 1.3.6.1.2.1.10.1.1.2.5.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOTSnSinkPrevDayLastInputPower 1.3.6.1.2.1.10.1.1.2.5.1.2
The last optical power monitored at the input during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSinkPrevDayLowInputPower 1.3.6.1.2.1.10.1.1.2.5.1.3
The lowest optical power monitored at the input during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSinkPrevDayHighInputPower 1.3.6.1.2.1.10.1.1.2.5.1.4
The highest optical power monitored at the input during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurrentTable 1.3.6.1.2.1.10.1.1.2.6
A table of OTSn source performance monitoring information for the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOTSnSrcCurrentEntry

optIfOTSnSrcCurrentEntry 1.3.6.1.2.1.10.1.1.2.6.1
A conceptual row that contains OTSn source performance monitoring information of an interface for the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOTSnSrcCurrentEntry  

optIfOTSnSrcCurrentSuspectedFlag 1.3.6.1.2.1.10.1.1.2.6.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOTSnSrcCurrentOutputPower 1.3.6.1.2.1.10.1.1.2.6.1.2
The optical power monitored at the output.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurrentLowOutputPower 1.3.6.1.2.1.10.1.1.2.6.1.3
The lowest optical power monitored at the output during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurrentHighOutputPower 1.3.6.1.2.1.10.1.1.2.6.1.4
The highest optical power monitored at the output during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurrentLowerOutputPowerThreshold 1.3.6.1.2.1.10.1.1.2.6.1.5
The lower limit threshold on output power. If optIfOTSnSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurrentUpperOutputPowerThreshold 1.3.6.1.2.1.10.1.1.2.6.1.6
The upper limit threshold on output power. If optIfOTSnSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurrentLaserTemp 1.3.6.1.2.1.10.1.1.2.6.1.7
The operating temperature of the laser.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurrentLowLaserTemp 1.3.6.1.2.1.10.1.1.2.6.1.8
The lowest operating temperature of the laser during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurrentHighLaserTemp 1.3.6.1.2.1.10.1.1.2.6.1.9
The highest operating temperature of the laser during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurrentLowerLaserTempThreshold 1.3.6.1.2.1.10.1.1.2.6.1.10
The lower limit threshold on laser temperature. If optIfOTSnSrcCurrentLaserTemp drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurrentUpperLaserTempThreshold 1.3.6.1.2.1.10.1.1.2.6.1.11
The upper limit threshold on laser temperature. If optIfOTSnSrcCurrentLaserTemp reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcIntervalTable 1.3.6.1.2.1.10.1.1.2.7
A table of historical OTSn source performance monitoring information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOTSnSrcIntervalEntry

optIfOTSnSrcIntervalEntry 1.3.6.1.2.1.10.1.1.2.7.1
A conceptual row that contains OTSn source performance monitoring information of an interface during a particular historical interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOTSnSrcIntervalEntry  

optIfOTSnSrcIntervalNumber 1.3.6.1.2.1.10.1.1.2.7.1.1
Uniquely identifies the interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntervalNumber  

optIfOTSnSrcIntervalSuspectedFlag 1.3.6.1.2.1.10.1.1.2.7.1.2
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOTSnSrcIntervalLastOutputPower 1.3.6.1.2.1.10.1.1.2.7.1.3
The last optical power monitored at the output during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcIntervalLowOutputPower 1.3.6.1.2.1.10.1.1.2.7.1.4
The lowest optical power monitored at the output during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcIntervalHighOutputPower 1.3.6.1.2.1.10.1.1.2.7.1.5
The highest optical power monitored at the output during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcIntervalLastLaserTemp 1.3.6.1.2.1.10.1.1.2.7.1.6
The last operating temperature of the laser during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcIntervalLowLaserTemp 1.3.6.1.2.1.10.1.1.2.7.1.7
The lowest operating temperature of the laser during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcIntervalHighLaserTemp 1.3.6.1.2.1.10.1.1.2.7.1.8
The highest operating temperature of the laser during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurDayTable 1.3.6.1.2.1.10.1.1.2.8
A table of OTSn source performance monitoring information for the current calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOTSnSrcCurDayEntry

optIfOTSnSrcCurDayEntry 1.3.6.1.2.1.10.1.1.2.8.1
A conceptual row that contains OTSn source performance monitoring information of an interface for the current calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOTSnSrcCurDayEntry  

optIfOTSnSrcCurDaySuspectedFlag 1.3.6.1.2.1.10.1.1.2.8.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOTSnSrcCurDayLowOutputPower 1.3.6.1.2.1.10.1.1.2.8.1.2
The lowest optical power monitored at the output during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurDayHighOutputPower 1.3.6.1.2.1.10.1.1.2.8.1.3
The highest optical power monitored at the output during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurDayLowLaserTemp 1.3.6.1.2.1.10.1.1.2.8.1.4
The lowest operating temperature of the laser during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcCurDayHighLaserTemp 1.3.6.1.2.1.10.1.1.2.8.1.5
The highest operating temperature of the laser during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcPrevDayTable 1.3.6.1.2.1.10.1.1.2.9
A table of OTSn source performance monitoring information for the previous calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOTSnSrcPrevDayEntry

optIfOTSnSrcPrevDayEntry 1.3.6.1.2.1.10.1.1.2.9.1
A conceptual row that contains OTSn source performance monitoring information of an interface for the previous calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOTSnSrcPrevDayEntry  

optIfOTSnSrcPrevDaySuspectedFlag 1.3.6.1.2.1.10.1.1.2.9.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOTSnSrcPrevDayLastOutputPower 1.3.6.1.2.1.10.1.1.2.9.1.2
The last optical power monitored at the output during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcPrevDayLowOutputPower 1.3.6.1.2.1.10.1.1.2.9.1.3
The lowest optical power monitored at the output during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcPrevDayHighOutputPower 1.3.6.1.2.1.10.1.1.2.9.1.4
The highest optical power monitored at the output during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcPrevDayLastLaserTemp 1.3.6.1.2.1.10.1.1.2.9.1.5
The last operating temperature of the laser during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcPrevDayLowLaserTemp 1.3.6.1.2.1.10.1.1.2.9.1.6
The lowest operating temperature of the laser during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTSnSrcPrevDayHighLaserTemp 1.3.6.1.2.1.10.1.1.2.9.1.7
The highest operating temperature of the laser during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnConfigTable 1.3.6.1.2.1.10.1.1.3.1
A table of OMSn configuration information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOMSnConfigEntry

optIfOMSnConfigEntry 1.3.6.1.2.1.10.1.1.3.1.1
A conceptual row that contains OMSn configuration information of an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOMSnConfigEntry  

optIfOMSnOrder 1.3.6.1.2.1.10.1.1.3.1.1.1
The number of multiplexed optical channels.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 1..900  

optIfOMSnCurrentStatus 1.3.6.1.2.1.10.1.1.3.1.1.2
Indicates the failure condition of the entity, if any.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noDefect(1), ssfP(2), ssfO(3), ssf(4), bdiP(5), bdiO(6), bdi(7), losP(8)  

optIfOMSnSinkCurrentTable 1.3.6.1.2.1.10.1.1.3.2
A table of OMSn sink performance monitoring information for the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOMSnSinkCurrentEntry

optIfOMSnSinkCurrentEntry 1.3.6.1.2.1.10.1.1.3.2.1
A conceptual row that contains OMSn sink performance monitoring information of an interface for the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOMSnSinkCurrentEntry  

optIfOMSnSinkCurrentSuspectedFlag 1.3.6.1.2.1.10.1.1.3.2.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOMSnSinkCurrentAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.2.1.2
The aggregated optical power of all the DWDM input channels.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurrentLowAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.2.1.3
The lowest aggregated optical power of all the DWDM input channels during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurrentHighAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.2.1.4
The highest aggregated optical power of all the DWDM input channels during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurrentLowerInputPowerThreshold 1.3.6.1.2.1.10.1.1.3.2.1.5
The lower limit threshold on aggregated input power. If optIfOMSnSinkCurrentAggregatedInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurrentUpperInputPowerThreshold 1.3.6.1.2.1.10.1.1.3.2.1.6
The upper limit threshold on aggregated input power. If optIfOMSnSinkCurrentAggregatedInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurrentLaserTemp 1.3.6.1.2.1.10.1.1.3.2.1.7
The operating temperature of the laser.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurrentLowLaserTemp 1.3.6.1.2.1.10.1.1.3.2.1.8
The lowest operating temperature of the laser during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurrentHighLaserTemp 1.3.6.1.2.1.10.1.1.3.2.1.9
The highest operating temperature of the laser during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurrentLowerLaserTempThreshold 1.3.6.1.2.1.10.1.1.3.2.1.10
The lower limit threshold on laser temperature. If optIfOMSnSinkCurrentLaserTemp drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurrentUpperLaserTempThreshold 1.3.6.1.2.1.10.1.1.3.2.1.11
The upper limit threshold on aggregated input power. If optIfOMSnSinkCurrentLaserTemp reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkIntervalTable 1.3.6.1.2.1.10.1.1.3.3
A table of historical OMSn sink performance monitoring information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOMSnSinkIntervalEntry

optIfOMSnSinkIntervalEntry 1.3.6.1.2.1.10.1.1.3.3.1
A conceptual row that contains OMSn sink performance monitoring information of an interface during a particular historical interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOMSnSinkIntervalEntry  

optIfOMSnSinkIntervalNumber 1.3.6.1.2.1.10.1.1.3.3.1.1
Uniquely identifies the interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntervalNumber  

optIfOMSnSinkIntervalSuspectedFlag 1.3.6.1.2.1.10.1.1.3.3.1.2
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOMSnSinkIntervalLastAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.3.1.3
The last aggregated optical power of all the DWDM input channels during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkIntervalLowAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.3.1.4
The lowest aggregated optical power of all the DWDM input channels during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkIntervalHighAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.3.1.5
The highest aggregated optical power of all the DWDM input channels during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkIntervalLastLaserTemp 1.3.6.1.2.1.10.1.1.3.3.1.6
The last operating temperature of the laser during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkIntervalLowLaserTemp 1.3.6.1.2.1.10.1.1.3.3.1.7
The lowest operating temperature of the laser during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkIntervalHighLaserTemp 1.3.6.1.2.1.10.1.1.3.3.1.8
The highest operating temperature of the laser during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurDayTable 1.3.6.1.2.1.10.1.1.3.4
A table of OMSn sink performance monitoring information for the current calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOMSnSinkCurDayEntry

optIfOMSnSinkCurDayEntry 1.3.6.1.2.1.10.1.1.3.4.1
A conceptual row that contains OMSn sink performance monitoring information of an interface for the current calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOMSnSinkCurDayEntry  

optIfOMSnSinkCurDaySuspectedFlag 1.3.6.1.2.1.10.1.1.3.4.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOMSnSinkCurDayLowAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.4.1.2
The lowest aggregated optical power of all the DWDM input channels during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurDayHighAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.4.1.3
The highest aggregated optical power of all the DWDM input channels during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurDayLowLaserTemp 1.3.6.1.2.1.10.1.1.3.4.1.4
The lowest operating temperature of the laser during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkCurDayHighLaserTemp 1.3.6.1.2.1.10.1.1.3.4.1.5
The highest operating temperature of the laser during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkPrevDayTable 1.3.6.1.2.1.10.1.1.3.5
A table of OMSn sink performance monitoring information for the previous calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOMSnSinkPrevDayEntry

optIfOMSnSinkPrevDayEntry 1.3.6.1.2.1.10.1.1.3.5.1
A conceptual row that contains OMSn sink performance monitoring information of an interface for the previous calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOMSnSinkPrevDayEntry  

optIfOMSnSinkPrevDaySuspectedFlag 1.3.6.1.2.1.10.1.1.3.5.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOMSnSinkPrevDayLastAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.5.1.2
The last aggregated optical power of all the DWDM input channels during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkPrevDayLowAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.5.1.3
The lowest aggregated optical power of all the DWDM input channels during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkPrevDayHighAggregatedInputPower 1.3.6.1.2.1.10.1.1.3.5.1.4
The highest aggregated optical power of all the DWDM input channels during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkPrevDayLastLaserTemp 1.3.6.1.2.1.10.1.1.3.5.1.5
The last operating temperature of the laser during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkPrevDayLowLaserTemp 1.3.6.1.2.1.10.1.1.3.5.1.6
The lowest operating temperature of the laser during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSinkPrevDayHighLaserTemp 1.3.6.1.2.1.10.1.1.3.5.1.7
The highest operating temperature of the laser during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurrentTable 1.3.6.1.2.1.10.1.1.3.6
A table of OMSn source performance monitoring information for the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOMSnSrcCurrentEntry

optIfOMSnSrcCurrentEntry 1.3.6.1.2.1.10.1.1.3.6.1
A conceptual row that contains OMSn source performance monitoring information of an interface for the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOMSnSrcCurrentEntry  

optIfOMSnSrcCurrentSuspectedFlag 1.3.6.1.2.1.10.1.1.3.6.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOMSnSrcCurrentOutputPower 1.3.6.1.2.1.10.1.1.3.6.1.2
The optical power monitored at the output.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurrentLowOutputPower 1.3.6.1.2.1.10.1.1.3.6.1.3
The lowest optical power monitored at the output during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurrentHighOutputPower 1.3.6.1.2.1.10.1.1.3.6.1.4
The highest optical power monitored at the output during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurrentLowerOutputPowerThreshold 1.3.6.1.2.1.10.1.1.3.6.1.5
The lower limit threshold on output power. If optIfOMSnSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurrentUpperOutputPowerThreshold 1.3.6.1.2.1.10.1.1.3.6.1.6
The upper limit threshold on output power. If optIfOMSnSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurrentLaserTemp 1.3.6.1.2.1.10.1.1.3.6.1.7
The operating temperature of the laser.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurrentLowLaserTemp 1.3.6.1.2.1.10.1.1.3.6.1.8
The lowest operating temperature of the laser during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurrentHighLaserTemp 1.3.6.1.2.1.10.1.1.3.6.1.9
The highest operating temperature of the laser during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurrentLowerLaserTempThreshold 1.3.6.1.2.1.10.1.1.3.6.1.10
The lower limit threshold on laser temperature. If optIfOMSnSrcCurrentLaserTemp drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurrentUpperLaserTempThreshold 1.3.6.1.2.1.10.1.1.3.6.1.11
The upper limit threshold on laser temperature. If optIfOMSnSrcCurrentLaserTemp reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcIntervalTable 1.3.6.1.2.1.10.1.1.3.7
A table of historical OMSn source performance monitoring information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOMSnSrcIntervalEntry

optIfOMSnSrcIntervalEntry 1.3.6.1.2.1.10.1.1.3.7.1
A conceptual row that contains OMSn source performance monitoring information of an interface during a particular historical interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOMSnSrcIntervalEntry  

optIfOMSnSrcIntervalNumber 1.3.6.1.2.1.10.1.1.3.7.1.1
Uniquely identifies the interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntervalNumber  

optIfOMSnSrcIntervalSuspectedFlag 1.3.6.1.2.1.10.1.1.3.7.1.2
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOMSnSrcIntervalLastOutputPower 1.3.6.1.2.1.10.1.1.3.7.1.3
The last optical power monitored at the output during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcIntervalLowOutputPower 1.3.6.1.2.1.10.1.1.3.7.1.4
The lowest optical power monitored at the output during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcIntervalHighOutputPower 1.3.6.1.2.1.10.1.1.3.7.1.5
The highest optical power monitored at the output during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcIntervalLastLaserTemp 1.3.6.1.2.1.10.1.1.3.7.1.6
The last operating temperature of the laser during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcIntervalLowLaserTemp 1.3.6.1.2.1.10.1.1.3.7.1.7
The lowest operating temperature of the laser during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcIntervalHighLaserTemp 1.3.6.1.2.1.10.1.1.3.7.1.8
The highest operating temperature of the laser during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurDayTable 1.3.6.1.2.1.10.1.1.3.8
A table of OMSn source performance monitoring information for the current calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOMSnSrcCurDayEntry

optIfOMSnSrcCurDayEntry 1.3.6.1.2.1.10.1.1.3.8.1
A conceptual row that contains OMSn source performance monitoring information of an interface for the current calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOMSnSrcCurDayEntry  

optIfOMSnSrcCurDaySuspectedFlag 1.3.6.1.2.1.10.1.1.3.8.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOMSnSrcCurDayLowOutputPower 1.3.6.1.2.1.10.1.1.3.8.1.2
The lowest optical power monitored at the output during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurDayHighOutputPower 1.3.6.1.2.1.10.1.1.3.8.1.3
The highest optical power monitored at the output during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurDayLowLaserTemp 1.3.6.1.2.1.10.1.1.3.8.1.4
The lowest operating temperature of the laser during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcCurDayHighLaserTemp 1.3.6.1.2.1.10.1.1.3.8.1.5
The highest operating temperature of the laser during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcPrevDayTable 1.3.6.1.2.1.10.1.1.3.9
A table of OMSn source performance monitoring information for the previous calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOMSnSrcPrevDayEntry

optIfOMSnSrcPrevDayEntry 1.3.6.1.2.1.10.1.1.3.9.1
A conceptual row that contains OMSn source performance monitoring information of an interface for the previous calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOMSnSrcPrevDayEntry  

optIfOMSnSrcPrevDaySuspectedFlag 1.3.6.1.2.1.10.1.1.3.9.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOMSnSrcPrevDayLastOutputPower 1.3.6.1.2.1.10.1.1.3.9.1.2
The last optical power monitored at the output during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcPrevDayLowOutputPower 1.3.6.1.2.1.10.1.1.3.9.1.3
The lowest optical power monitored at the output during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcPrevDayHighOutputPower 1.3.6.1.2.1.10.1.1.3.9.1.4
The highest optical power monitored at the output during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcPrevDayLastLaserTemp 1.3.6.1.2.1.10.1.1.3.9.1.5
The last operating temperature of the laser during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcPrevDayLowLaserTemp 1.3.6.1.2.1.10.1.1.3.9.1.6
The lowest operating temperature of the laser during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOMSnSrcPrevDayHighLaserTemp 1.3.6.1.2.1.10.1.1.3.9.1.7
The highest operating temperature of the laser during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChConfigTable 1.3.6.1.2.1.10.1.1.4.4
A table of OCh configuration information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOChConfigEntry

optIfOChConfigEntry 1.3.6.1.2.1.10.1.1.4.4.1
A conceptual row that contains OCh configuration information of an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOChConfigEntry  

optIfOChSinkAdaptActive 1.3.6.1.2.1.10.1.1.2.1.1.1
Indicates whether the sink adaptation function is activated or not.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

optIfOChSourceAdaptActive 1.3.6.1.2.1.10.1.1.2.1.1.2
Indicates whether the source adaptation function is activated or not.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

optIfOChSinkFECEnabled 1.3.6.1.2.1.10.1.1.2.1.1.3
If Forward Error Correction (FEC) is supported, this object indicates whether FEC at the OCh sink adaptation function is enabled or not.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

optIfOChCurrentStatus 1.3.6.1.2.1.10.1.1.4.4.1.4
Indicates the failure condition of the entity, if any.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noDefect(1), ais(2), lof(3), lom(4), los(5), losP(6), oci(7), ssfP(8), ssfO(9), ssf(10)  

optIfOChSinkCurrentTable 1.3.6.1.2.1.10.1.1.4.5
A table of OCh sink performance monitoring information for the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOChSinkCurrentEntry

optIfOChSinkCurrentEntry 1.3.6.1.2.1.10.1.1.4.5.1
A conceptual row that contains OCh sink performance monitoring information for an interface for the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOChSinkCurrentEntry  

optIfOChSinkCurrentSuspectedFlag 1.3.6.1.2.1.10.1.1.4.5.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOChSinkCurrentInputPower 1.3.6.1.2.1.10.1.1.4.5.1.2
The optical power monitored at the input.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSinkCurrentLowInputPower 1.3.6.1.2.1.10.1.1.4.5.1.3
The lowest optical power monitored at the input during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSinkCurrentHighInputPower 1.3.6.1.2.1.10.1.1.4.5.1.4
The highest optical power monitored at the input during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSinkCurrentLowerInputPowerThreshold 1.3.6.1.2.1.10.1.1.4.5.1.5
The lower limit threshold on input power. If optIfOChSinkCurrentInputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOChSinkCurrentUpperInputPowerThreshold 1.3.6.1.2.1.10.1.1.4.5.1.6
The upper limit threshold on input power. If optIfOChSinkCurrentInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOChSinkIntervalTable 1.3.6.1.2.1.10.1.1.4.6
A table of historical OCh sink performance monitoring information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOChSinkIntervalEntry

optIfOChSinkIntervalEntry 1.3.6.1.2.1.10.1.1.4.6.1
A conceptual row that contains OCh sink performance monitoring information of an interface during a particular historical interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOChSinkIntervalEntry  

optIfOChSinkIntervalNumber 1.3.6.1.2.1.10.1.1.4.6.1.1
Uniquely identifies the interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntervalNumber  

optIfOChSinkIntervalSuspectedFlag 1.3.6.1.2.1.10.1.1.4.6.1.2
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOChSinkIntervalLastInputPower 1.3.6.1.2.1.10.1.1.4.6.1.3
The last optical power monitored at the input during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSinkIntervalLowInputPower 1.3.6.1.2.1.10.1.1.4.6.1.4
The lowest optical power monitored at the input during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSinkIntervalHighInputPower 1.3.6.1.2.1.10.1.1.4.6.1.5
The highest optical power monitored at the input during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSinkCurDayTable 1.3.6.1.2.1.10.1.1.4.7
A table of OCh sink performance monitoring information for the current calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOChSinkCurDayEntry

optIfOChSinkCurDayEntry 1.3.6.1.2.1.10.1.1.4.7.1
A conceptual row that contains OCh sink performance monitoring information of an interface for the current calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOChSinkCurDayEntry  

optIfOChSinkCurDaySuspectedFlag 1.3.6.1.2.1.10.1.1.4.7.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOChSinkCurDayLowInputPower 1.3.6.1.2.1.10.1.1.4.7.1.2
The lowest optical power monitored at the input during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSinkCurDayHighInputPower 1.3.6.1.2.1.10.1.1.4.7.1.3
The highest optical power monitored at the input during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSinkPrevDayTable 1.3.6.1.2.1.10.1.1.4.8
A table of OCh sink performance monitoring information for the previous calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOChSinkPrevDayEntry

optIfOChSinkPrevDayEntry 1.3.6.1.2.1.10.1.1.4.8.1
A conceptual row that contains OCh sink performance monitoring information of an interface for the previous calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOChSinkPrevDayEntry  

optIfOChSinkPrevDaySuspectedFlag 1.3.6.1.2.1.10.1.1.4.8.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOChSinkPrevDayLastInputPower 1.3.6.1.2.1.10.1.1.4.8.1.2
The last optical power monitored at the input during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSinkPrevDayLowInputPower 1.3.6.1.2.1.10.1.1.4.8.1.3
The lowest optical power monitored at the input during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSinkPrevDayHighInputPower 1.3.6.1.2.1.10.1.1.4.8.1.4
The highest optical power monitored at the input during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurrentTable 1.3.6.1.2.1.10.1.1.4.9
A table of OCh source performance monitoring information for the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOChSrcCurrentEntry

optIfOChSrcCurrentEntry 1.3.6.1.2.1.10.1.1.4.9.1
A conceptual row that contains OCh source performance monitoring information of an interface for the current 15 minute interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOChSrcCurrentEntry  

optIfOChSrcCurrentSuspectedFlag 1.3.6.1.2.1.10.1.1.4.9.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOChSrcCurrentOutputPower 1.3.6.1.2.1.10.1.1.4.9.1.2
The optical power monitored at the output.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurrentLowOutputPower 1.3.6.1.2.1.10.1.1.4.9.1.3
The lowest optical power monitored at the output during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurrentHighOutputPower 1.3.6.1.2.1.10.1.1.4.9.1.4
The highest optical power monitored at the output during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurrentLowerOutputPowerThreshold 1.3.6.1.2.1.10.1.1.4.9.1.5
The lower limit threshold on output power. If optIfOChSrcCurrentOutputPower drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurrentUpperOutputPowerThreshold 1.3.6.1.2.1.10.1.1.4.9.1.6
The upper limit threshold on output power. If optIfOChSrcCurrentOutputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurrentLaserTemp 1.3.6.1.2.1.10.1.1.4.9.1.7
The operating temperature of the laser.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurrentLowLaserTemp 1.3.6.1.2.1.10.1.1.4.9.1.8
The lowest operating temperature of the laser during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurrentHighLaserTemp 1.3.6.1.2.1.10.1.1.4.9.1.9
The highest operating temperature of the laser during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurrentLowerLaserTempThreshold 1.3.6.1.2.1.10.1.1.4.9.1.10
The lower limit threshold on laser temperature. If optIfOChSrcCurrentLaserTemp drops to this value or below, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurrentUpperLaserTempThreshold 1.3.6.1.2.1.10.1.1.4.9.1.11
The upper limit threshold on laser temperature. If optIfOChSrcCurrentLaserTemp reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOChSrcIntervalTable 1.3.6.1.2.1.10.1.1.4.10
A table of historical OCh source performance monitoring information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOChSrcIntervalEntry

optIfOChSrcIntervalEntry 1.3.6.1.2.1.10.1.1.4.10.1
A conceptual row that contains OCh source performance monitoring information of an interface during a particular historical interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOChSrcIntervalEntry  

optIfOChSrcIntervalNumber 1.3.6.1.2.1.10.1.1.4.10.1.1
Uniquely identifies the interval.
Status: current Access: not-accessible
OBJECT-TYPE    
  IntervalNumber  

optIfOChSrcIntervalSuspectedFlag 1.3.6.1.2.1.10.1.1.4.10.1.2
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOChSrcIntervalLastOutputPower 1.3.6.1.2.1.10.1.1.4.10.1.3
The last optical power monitored at the output during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcIntervalLowOutputPower 1.3.6.1.2.1.10.1.1.4.10.1.4
The lowest optical power monitored at the output during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcIntervalHighOutputPower 1.3.6.1.2.1.10.1.1.4.10.1.5
The highest optical power monitored at the output during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcIntervalLastLaserTemp 1.3.6.1.2.1.10.1.1.4.10.1.6
The last operating temperature of the laser during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcIntervalLowLaserTemp 1.3.6.1.2.1.10.1.1.4.10.1.7
The lowest operating temperature of the laser during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcIntervalHighLaserTemp 1.3.6.1.2.1.10.1.1.4.10.1.8
The highest operating temperature of the laser during the interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurDayTable 1.3.6.1.2.1.10.1.1.4.11
A table of OCh source performance monitoring information for the current calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOChSrcCurDayEntry

optIfOChSrcCurDayEntry 1.3.6.1.2.1.10.1.1.4.11.1
A conceptual row that contains OCh source performance monitoring information of an interface for the current calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOChSrcCurDayEntry  

optIfOChSrcCurDaySuspectedFlag 1.3.6.1.2.1.10.1.1.4.11.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOChSrcCurDayLowOutputPower 1.3.6.1.2.1.10.1.1.4.11.1.2
The lowest optical power monitored at the output during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurDayHighOutputPower 1.3.6.1.2.1.10.1.1.4.11.1.3
The highest optical power monitored at the output during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurDayLowLaserTemp 1.3.6.1.2.1.10.1.1.4.11.1.4
The lowest operating temperature of the laser during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcCurDayHighLaserTemp 1.3.6.1.2.1.10.1.1.4.11.1.5
The highest operating temperature of the laser during the current calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcPrevDayTable 1.3.6.1.2.1.10.1.1.4.12
A table of OCh source performance monitoring information for the previous calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOChSrcPrevDayEntry

optIfOChSrcPrevDayEntry 1.3.6.1.2.1.10.1.1.4.12.1
A conceptual row that contains OCh source performance monitoring information of an interface for the previous calendar day.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOChSrcPrevDayEntry  

optIfOChSrcPrevDaySuspectedFlag 1.3.6.1.2.1.10.1.1.4.12.1.1
If true, the data in this entry may be unreliable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

optIfOChSrcPrevDayLastOutputPower 1.3.6.1.2.1.10.1.1.4.12.1.2
The last optical power monitored at the output during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcPrevDayLowOutputPower 1.3.6.1.2.1.10.1.1.4.12.1.3
The lowest optical power monitored at the output during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcPrevDayHighOutputPower 1.3.6.1.2.1.10.1.1.4.12.1.4
The highest optical power monitored at the output during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcPrevDayLastLaserTemp 1.3.6.1.2.1.10.1.1.4.12.1.5
The last operating temperature of the laser during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcPrevDayLowLaserTemp 1.3.6.1.2.1.10.1.1.4.12.1.6
The lowest operating temperature of the laser during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOChSrcPrevDayHighLaserTemp 1.3.6.1.2.1.10.1.1.4.12.1.7
The highest operating temperature of the laser during the previous calendar day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optIfOTUkConfigTable 1.3.6.1.2.1.10.1.1.4.1.1
A table of OTUk configuration information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfOTUkConfigEntry

optIfOTUkConfigEntry 1.3.6.1.2.1.10.1.1.4.1.1.1
A conceptual row that contains OTUk configuration information of an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfOTUkConfigEntry  

optIfOTUkTraceIdentifierTransmitted 1.3.6.1.2.1.10.1.1.4.1.1.1.1
The trace identifier transmitted.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..64)  

optIfOTUkDAPIExpected 1.3.6.1.2.1.10.1.1.4.1.1.1.2
The DAPI expected by the receiver.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..16)  

optIfOTUkSAPIExpected 1.3.6.1.2.1.10.1.1.4.1.1.1.3
The SAPI expected by the receiver.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..16)  

optIfOTUkTraceIdentifierAccepted 1.3.6.1.2.1.10.1.1.4.1.1.1.4
The actual trace identifier accepted.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..64)  

optIfOTUkAcTIStatus 1.3.6.1.2.1.10.1.1.4.1.1.1.5
The status of the accepted Trail Trace Identifier by the receiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stable(1), unstable(2)  

optIfOTUkTIMDetMode 1.3.6.1.2.1.10.1.1.4.1.1.1.6
Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), dapi(2), sapi(3), both(4)  

optIfOTUkTIMActEnabled 1.3.6.1.2.1.10.1.1.4.1.1.1.7
Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

optIfOTUkDEGThr 1.3.6.1.2.1.10.1.1.4.1.1.1.8
Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to DEGTHR.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOTUkDEGM 1.3.6.1.2.1.10.1.1.4.1.1.1.9
Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if DEGM consecutive bad PM Seconds are detected.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfOTUkCurrentStatus 1.3.6.1.2.1.10.1.1.4.1.1.1.10
Indicates the failure condition of the entity, if any.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noDefect(1), tim(2), deg(3), bdi(4), ssf(5)  

optIfODUkTSinkConfigTable 1.3.6.1.2.1.10.1.1.4.2.1
A table of ODUkT TCM Sink configuration information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfODUkTSinkConfigEntry

optIfODUkTSinkConfigEntry 1.3.6.1.2.1.10.1.1.4.2.1.1
A conceptual row that contains ODUkT Sink configuration information of an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfODUkTSinkConfigEntry  

optIfODUkTTcmId 1.3.6.1.2.1.10.1.1.4.2.1.1.1
Value of the TCM level
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..6  

optIfODUkTDAPIExpected 1.3.6.1.2.1.10.1.1.4.2.1.1.2
The DAPI expected by the receiver.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..16)  

optIfODUkTSAPIExpected 1.3.6.1.2.1.10.1.1.4.2.1.1.3
The SAPI expected by the receiver.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..16)  

optIfODUkTTraceIdentifierAccepted 1.3.6.1.2.1.10.1.1.4.2.1.1.4
The actual trace identifier accepted.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..64)  

optIfODUkTAcTIStatus 1.3.6.1.2.1.10.1.1.4.2.1.1.5
The status of the accepted Trail Trace Identifier by the receiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stable(1), unstable(2)  

optIfODUkTTIMDetMode 1.3.6.1.2.1.10.1.1.4.2.1.1.6
Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), dapi(2), sapi(3), both(4)  

optIfODUkTTIMActEnabled 1.3.6.1.2.1.10.1.1.4.2.1.1.7
Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

optIfODUkTDEGThr 1.3.6.1.2.1.10.1.1.4.2.1.1.8
Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to DEGTHR.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfODUkTDEGM 1.3.6.1.2.1.10.1.1.4.2.1.1.9
Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if DEGM consecutive bad PM Seconds are detected.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfODUkTSinkMode 1.3.6.1.2.1.10.1.1.4.2.1.1.10
Controls the detection of the TCM sub-fields at the Sink: If the value is TRANSPARENT, the TCM sub-fields were not inserted. If the value is OPERATIONAL, then: - Trail Trace Identifier is inserted in the TTI byte position - Backward Defect Indication is inserted in the BDI bit position - Bit Interleaved Parity (BIP-8) is inserted in the BIP8 byte position - Bits 6, 7 and 8 of byte BI shall be fixed to 000 (reserved)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER transparent(1), operational(2)  

optIfODUkTSinkLockSignalAdminState 1.3.6.1.2.1.10.1.1.4.2.1.1.11
Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the ODUKT sink. When a Tandem Connection endpoint is set to admin state locked, it inserts the ODUk-LCK signal in the sink direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER locked(1), normal(2)  

optIfODUkTCurrentStatus 1.3.6.1.2.1.10.1.1.4.2.1.1.12
Indicates the failure condition of the entity, if any.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noDefect(1), oci(2), lck(3), tim(4), deg(5), bdi(6), ssf(7)  

optIfODUkTSourceConfigTable 1.3.6.1.2.1.10.1.1.4.2.2
A table of ODUkT TCM Source configuration information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfODUkTSourceConfigEntry

optIfODUkTSourceConfigEntry 1.3.6.1.2.1.10.1.1.4.2.2.1
A conceptual row that contains ODUkT Source configuration information of an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfODUkTSourceConfigEntry  

optIfODUkTTcmId 1.3.6.1.2.1.10.1.1.4.2.2.1.1
Value of the TCM level
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..6  

optIfODUkTTraceIdentifierTransmitted 1.3.6.1.2.1.10.1.1.4.2.2.1.2
The trace identifier transmitted.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..64)  

optIfODUkTSourceMode 1.3.6.1.2.1.10.1.1.4.2.2.1.3
Controls the detection of the TCM sub-fields at the Source: If the value is TRANSPARENT, all information shall be passed through transparently, with the exception of the TCM ACT. If the value is OPERATIONAL, then: - Trail Trace Identifier is inserted in the TTI byte position - Backward Defect Indication is inserted in the BDI bit position - Bit Interleaved Parity (BIP-8) is inserted in the BIP8 byte position - Bits 6, 7 and 8 of byte BI shall be fixed to 000 (reserved)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER transparent(1), operational(2)  

optIfODUkTSourceLockSignalAdminState 1.3.6.1.2.1.10.1.1.4.2.2.1.4
Provides the capability to provision the LOCK signal, which is one of the ODUk maintenance signals, at the source. When a Tandem Connection endpoint is set to admin state locked, it inserts the ODUk-LCK signal in the source direction.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER locked(1), normal(2)  

optIfODUkPConfigTable 1.3.6.1.2.1.10.1.1.4.3.1
A table of ODUkP configuration information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptIfODUkPConfigEntry

optIfODUkPConfigEntry 1.3.6.1.2.1.10.1.1.4.3.1.1
A conceptual row that contains ODUkP configuration information of an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptIfODUkPConfigEntry  

optIfODUkPTraceIdentifierTransmitted 1.3.6.1.2.1.10.1.1.4.3.1.1.1
The trace identifier transmitted.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..64)  

optIfODUkPDAPIExpected 1.3.6.1.2.1.10.1.1.4.3.1.1.2
The DAPI expected by the receiver.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..16)  

optIfODUkPSAPIExpected 1.3.6.1.2.1.10.1.1.4.3.1.1.3
The SAPI expected by the receiver.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..16)  

optIfODUkPTraceIdentifierAccepted 1.3.6.1.2.1.10.1.1.4.3.1.1.4
The actual trace identifier accepted.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..64)  

optIfODUkPAcTIStatus 1.3.6.1.2.1.10.1.1.4.3.1.1.5
The status of the accepted Trail Trace Identifier by the receiver.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stable(1), unstable(2)  

optIfODUkPTIMDetMode 1.3.6.1.2.1.10.1.1.4.3.1.1.6
Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), dapi(2), sapi(3), both(4)  

optIfODUkPTIMActEnabled 1.3.6.1.2.1.10.1.1.4.3.1.1.7
Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

optIfODUkPDEGThr 1.3.6.1.2.1.10.1.1.4.3.1.1.8
Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the percentage of detected errored blocks in that second is greater than or equal to DEGTHR.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfODUkPDEGM 1.3.6.1.2.1.10.1.1.4.3.1.1.9
Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if DEGM consecutive bad PM Seconds are detected.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

optIfODUkPCurrentStatus 1.3.6.1.2.1.10.1.1.4.3.1.1.10
Indicates the failure condition of the entity, if any.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noDefect(1), lck(2), tim(3), oci(4), deg(5), bdi(6), ssf(7), plm(8)  

optIfODUkPPayloadTypeTransmitted 1.3.6.1.2.1.10.1.1.4.3.1.1.11
The payload type signal transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

optIfODUkPPayloadTypeExpected 1.3.6.1.2.1.10.1.1.4.3.1.1.12
The payload type signal expected by the receiver.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

optIfODUkPPayloadTypeAccepted 1.3.6.1.2.1.10.1.1.4.3.1.1.13
The actual payload type signal accepted.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

optIfODUkPActiveAdaptFuncSource 1.3.6.1.2.1.10.1.1.4.3.1.1.14
When an ODUkP termination point supports multiple adaptation functions, this object indicates the active adaptation function at the interface port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cBRa2G5(1), cBRa10G(2), cBRa40G(3), cBRb2G5(4), cBRb10G(5), cBRb40G(6), aTMvp(7), gFP(8), nULL(9), pRBS(10), rSn(11), gcc(12), aps(13)  

optIfODUkPActiveAdaptFuncSink 1.3.6.1.2.1.10.1.1.4.3.1.1.15
When an ODUkP termination point supports multiple adaptation functions, this object indicates the active adaptation function at the interface port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cBR2G5(1), cBR10G(2), cBR40G(3), aTMvp(4), gFP(5), nULL(6), pRBS(7), rSn(8), gcc(9), aps(10)  

optIfPerfMonGroup 1.3.6.1.2.1.10.1.2.1.1
A collection of performance monitoring interval objects.
Status: current Access: read-write
OBJECT-GROUP    

optIfOTSnConfigGroup 1.3.6.1.2.1.10.1.2.1.2
A collection of OTSn configuration objects.
Status: current Access: read-write
OBJECT-GROUP    

optIfOTSnPMGroup 1.3.6.1.2.1.10.1.2.1.3
A collection of OTSn performance monitoring objects.
Status: current Access: read-write
OBJECT-GROUP    

optIfOMSnConfigGroup 1.3.6.1.2.1.10.1.2.1.4
A collection of OMSn configuration objects.
Status: current Access: read-write
OBJECT-GROUP    

optIfOMSnPMGroup 1.3.6.1.2.1.10.1.2.1.5
A collection of OMSn performance monitoring objects.
Status: current Access: read-write
OBJECT-GROUP    

optIfOChConfigGroup 1.3.6.1.2.1.10.1.2.1.6
A collection of OCh configuration objects.
Status: current Access: read-write
OBJECT-GROUP    

optIfOChPMGroup 1.3.6.1.2.1.10.1.2.1.7
A collection of OCh performance monitoring objects.
Status: current Access: read-write
OBJECT-GROUP    

optIfOTUkConfigGroup 1.3.6.1.2.1.10.1.2.1.8
A collection of OTUk configuration objects.
Status: current Access: read-write
OBJECT-GROUP    

optIfODUkTGroup 1.3.6.1.2.1.10.1.2.1.9
A collection of ODUkT configuration objects.
Status: current Access: read-write
OBJECT-GROUP    

optIfODUkPGroup 1.3.6.1.2.1.10.1.2.1.10
A collection of ODUkP configuration objects.
Status: current Access: read-write
OBJECT-GROUP    

optIfMinCompl 1.3.6.1.2.1.10.1.2.2.1
The minimal implementation requirements for this MIB module.
Status: current Access: read-write
MODULE-COMPLIANCE    

optIfFullCompl 1.3.6.1.2.1.10.1.2.2.2
The full implementation requirements for this MIB module.
Status: current Access: read-write
MODULE-COMPLIANCE