PDN-CP-IWF-MIB

File: PDN-CP-IWF-MIB.mib (44405 bytes)

Imported modules

SNMPv2-CONF PDN-HEADER-MIB PDN-TC
IF-MIB SNMPv2-SMI SNMPv2-TC

Imported symbols

OBJECT-GROUP MODULE-COMPLIANCE pdnCpIwf
SwitchState InterfaceIndex ifIndex
Integer32 Counter32 OBJECT-TYPE
MODULE-IDENTITY RowStatus TEXTUAL-CONVENTION
DisplayString TruthValue

Defined Types

CpIwfRegion  
Different regions define an specific group of parameters
TEXTUAL-CONVENTION    
  INTEGER usa(1), canada(2)  

GatewayProtocol  
Gateway protocols supported by CPIWF running on this agent
TEXTUAL-CONVENTION    
  INTEGER lescas(1), voiceband(2), mgcp(3), sip(4)  

HookState  
This textual convention defines the different hook status for POTS ports.
TEXTUAL-CONVENTION    
  INTEGER onhook(1), offhook(2), ringground(3)  

PotsSignaling  
This textual convention defines the possible signaling types for POTS ports.
TEXTUAL-CONVENTION    
  INTEGER loopstart(1), groundstart(2)  

ControlProtocol  
This textual convention defines the control protocol capabilities of the CpIwf. Each bit position in the bitmap corresponds to an specific protocol. If the bit is 1, that protocol is supported. Bit 0 : cas (channel associated signaling) Bit 1 : eoc (embedded operation channel) Bit 2 : ccs/elcp (common signaling channel/ emulated loop control protocol) Bit 3 : Not used (Future) Bit 4 : Not used (Future) Bit 5 : Not used (Future) Bit 6 : Not used (Future) Bit 7 : Not used (Future)
TEXTUAL-CONVENTION    
  BITS cas(0), eoc(1), ccselcp(2)  

VoiceEncoding  
This textual convention defines the voice encoding capabilities of the POTS port.
TEXTUAL-CONVENTION    
  INTEGER g711(0), g726(1), g729(2)  

PdnPotsTestTypes  
This textual convention defines the possible test types for POTS ports.
TEXTUAL-CONVENTION    
  INTEGER noTest(1), loopback(2), ringsignal(3)  

PdnCpIwfEntry  
SEQUENCE    
  pdnCpIwfIndex Integer32
  pdnCpIwfIfIndex InterfaceIndex
  pdnCpIwfRowStatus RowStatus
  pdnCpIwfNumPotsAssigned Integer32
  pdnCpIwfGatewayProtocol GatewayProtocol
  pdnCpIwfAtmBLESCapability ControlProtocol
  pdnCpIwfSscsPredefinedProfile Integer32
  pdnCpIwfJitterBufferLength Integer32

PdnCpIwfMappingEntry  
SEQUENCE    
  pdnCpIwfMappingIndex Integer32

PdnPotsPortEntry  
SEQUENCE    
  pdnPotsPortIfIndex InterfaceIndex
  pdnPotsPortCpIwfIndex Integer32
  pdnPotsPortHookStatus HookState
  pdnPotsPortSignalingMethod PotsSignaling
  pdnPotsPortTxGain Integer32
  pdnPotsPortRxGain Integer32
  pdnPotsPortCustInfo DisplayString
  pdnPotsPortG729VoiceCodec SwitchState
  pdnPotsPortPreferedVoiceCodec VoiceEncoding
  pdnPotsPortPreferredPacketPeriod Integer32
  pdnPotsPortSilenceSuppression SwitchState
  pdnPotsPortActualVoiceCodec VoiceEncoding
  pdnPotsPortCallElapsedTime Integer32
  pdnPotsPortModemDetected TruthValue
  pdnPotsPortEchoCanceller INTEGER
  pdnPotsPortLocalEndName DisplayString
  pdnPotsPortActiveSoftswitch INTEGER

PdnCpIwfAal2StatsEntry  
SEQUENCE    
  pdnCpIwfAal2CpsRxPkts Counter32
  pdnCpIwfAal2CpsTxPkts Counter32
  pdnCpIwfAal2CpsParityErrors Counter32
  pdnCpIwfAal2CpsSeqNumErrors Counter32
  pdnCpIwfAal2CpsOsfMismatchErrors Counter32
  pdnCpIwfAal2CpsOsfErrors Counter32
  pdnCpIwfAal2CpsHecErrors Counter32
  pdnCpIwfAal2CpsOversizeSduErrors Counter32
  pdnCpIwfAal2CpsReassemblyErrors Counter32
  pdnCpIwfAal2CpsHecOverlapErrors Counter32
  pdnCpIwfAal2CpsUuiErrors Counter32
  pdnCpIwfAal2CpsCidErrors Counter32

PdnPotsPortStatsEntry  
SEQUENCE    
  pdnPotsPortTotalCalls Counter32
  pdnPotsPortTotalCallsFailure Counter32
  pdnPotsPortTotalCallsDropped Counter32
  pdnPotsPortInCallsReceived Counter32
  pdnPotsPortInCallsAnswered Counter32
  pdnPotsPortInCallsConnected Counter32
  pdnPotsPortInCallsFailure Counter32
  pdnPotsPortOutCallsAttempted Counter32
  pdnPotsPortOutCallsAnswered Counter32
  pdnPotsPortOutCallsConnected Counter32
  pdnPotsPortOutCallsFailure Counter32
  pdnPotsPortPacketsSent Counter32
  pdnPotsPortPacketsReceived Counter32
  pdnPotsPortPacketsLost Counter32
  pdnPotsPortBytesSent Counter32
  pdnPotsPortBytesReceived Counter32

PdnPotsTestEntry  
SEQUENCE    
  pdnPotsTestType PdnPotsTestTypes
  pdnPotsTestCmd INTEGER
  pdnPotsTestStatus INTEGER

Defined Values

pdnCpIwfMIB 1.3.6.1.4.1.1795.2.24.2.50.1
This module defines a portion of the management information base (MIB) for managing multiple Loop Emulation Service (LES) Customer Premises Interworking Functions (CP-IWF). The mib recommended by the ATM forum (af-vmoa-0145.000) lacks the ability to manage multiple CP-IWFs as required by the Paradyne DSLAM products. This enterprise mib is meant to be used in connection with RFC 2863 which defines the ifTable.
MODULE-IDENTITY    

pdnCpIwfNotifications 1.3.6.1.4.1.1795.2.24.2.50.1.0
OBJECT IDENTIFIER    

pdnCpIwfMIBObjects 1.3.6.1.4.1.1795.2.24.2.50.1.1
OBJECT IDENTIFIER    

pdnCpIwfMIBConformance 1.3.6.1.4.1.1795.2.24.2.50.1.2
OBJECT IDENTIFIER    

pdnCpIwfConfigObjects 1.3.6.1.4.1.1795.2.24.2.50.1.1.1
OBJECT IDENTIFIER    

pdnCpIwfTestObjects 1.3.6.1.4.1.1795.2.24.2.50.1.1.2
OBJECT IDENTIFIER    

pdnCpIwfStatsObjects 1.3.6.1.4.1.1795.2.24.2.50.1.1.3
OBJECT IDENTIFIER    

pdnCpIwfTotalNumber 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.1
Indicates the total number of CpIwfs correctly configured in this system.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

pdnCpIwfIndexNext 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.2
This object contains an appropriate value to be used for pdnCpIwfIndex when creating entries in the pdnCpIwfTable. The value 0 indicates that no unassigned entries are available. To obtain the pdnCpIwfIndexNext value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index. After a manager retrieves a value the agent will determine through its local policy when this index value will be made available for reuse.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2147483647  

pdnCpIwfRegion 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.3
This object permits the selection of a regional set of parameters that apply to the entire device.
Status: current Access: read-write
OBJECT-TYPE    
  CpIwfRegion  

pdnCpIwfTable 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4
The Cp-Iwf Configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PdnCpIwfEntry

pdnCpIwfEntry 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1
An entry in the Cp-Iwf configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PdnCpIwfEntry  

pdnCpIwfIndex 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.1
This object is an arbitrary index assigned by the agent. When a client wishes to add an entry to this pdnCpIwfTable, first it must do a get to the pdnCpIwfIndexNext and use the returned value as the table's index for the new entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..2147483647  

pdnCpIwfIfIndex 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.2
This object displays the interface index from the ifTable assigned by the SNMP agent upon creation of this CPIWF.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

pdnCpIwfRowStatus 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.3
rowStatus object that allows creation and deletion of CpIwfs.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

pdnCpIwfNumPotsAssigned 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.4
This object maintains the number of pots ports currently assigned to this CpIwf. It is not required that a new created CpIwf has Pots ports assigned to it. Moreover, the default value for this object can be implementation specific, for example: - assign all 24 POTS ports to the CpIwf port upon creation. - assign a minimum number of POTS to the CpIwf port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..24  

pdnCpIwfGatewayProtocol 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.5
This is the Gateway protocol configured for this CPIWF.
Status: current Access: read-create
OBJECT-TYPE    
  GatewayProtocol  

pdnCpIwfAtmBLESCapability 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.6
This object indicates whether this CP-IWF supports the ATM Forum BLES standard with CCS and ELCP and EOC.
Status: current Access: read-only
OBJECT-TYPE    
  ControlProtocol  

pdnCpIwfSscsPredefinedProfile 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.7
This object allows selection of predefined profiles for use by voice/voiceband data connections using UUI codepoints 0-15 with type 1 packets. The ATM Forum predefined profiles are specified in Annex A: ATM Forum Predefined Profiles (see reference below). Implementations are not required to support every profile. Thus, an SNMP set on this object to an unsupported profile must result in an SNMP Response with error status of badValue(3). Examples of profiles and its attributes values: <> (PCM-64, 44 Octet packets, without silence): ------------------------------------------------------------------------------- UUI | Packet | Encoding | Description | | Packet | Seq.No Codepoint | Length | Format | of | M | Time | Interval Range | (octets) | Reference | Algorithm | | (ms) | (ms) ------------------------------------------------------------------------------- 0-15 44 Fig B-1/I.366.2 PCM, G.711-64, 1 5.5 5.5 Generic <> (PCM-64 and ADPCM-32, 44 Octet packets, without silence): ------------------------------------------------------------------------------- UUI | Packet | Encoding | Description | | Packet | Seq.No Codepoint | Length | Format | of | M | Time | Interval Range | (octets) | Reference | Algorithm | | (ms) | (ms) ------------------------------------------------------------------------------- 0-7 44 Fig B-1/I.366.2 PCM, G.711-64, 1 5.5 5.5 Generic 7-15 44 Fig E-2/I.366.2 ADPCM, G.726-32 1 5.5 5.5
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

pdnCpIwfJitterBufferLength 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.4.1.8
This object allows the configuration of the jitter buffer length.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 10..120  

pdnCpIwfMappingTable 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.5
A table mapping the 'ifIndex' values of 'pdnCpIwfIfIndex' to the 'pdnCpIwfIndex' values of the corresponding CpIwf.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PdnCpIwfMappingEntry

pdnCpIwfMappingEntry 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.5.1
Each row describes the mapping of one ifIndex to a pdnCpIwfIndex.
Status: current Access: not-accessible
OBJECT-TYPE    
  PdnCpIwfMappingEntry  

pdnCpIwfMappingIndex 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.5.1.1
The index assigned to the Cp-Iwf's interface upon creation.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

pdnPotsPortTable 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6
The Pots port Configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PdnPotsPortEntry

pdnPotsPortEntry 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1
An entry in the Pots Port configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  PdnPotsPortEntry  

pdnPotsPortIfIndex 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.1
ifIndex value from ifTable for this POTS port.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

pdnPotsPortCpIwfIndex 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.2
The value of this object corresponds to a valid pdnCpIwfIndex in the pdnCpIwfTable or '0' which has the meaning of 'not-assigned'. The value 0 is expected to be used during changes on the assignment of Pots ports, that is, a Pots port initially assigned to a CpIwf port needs to be un-assigned first and then assigned to the new CpIwf Port.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

pdnPotsPortHookStatus 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.3
Current hook status of this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  HookState  

pdnPotsPortSignalingMethod 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.4
Signaling method selected for this POTS port.
Status: current Access: read-write
OBJECT-TYPE    
  PotsSignaling  

pdnPotsPortTxGain 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.5
This is the gain in the analog-to-digital direction (towards the uplink).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -24..23  

pdnPotsPortRxGain 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.6
This is the gain in the digital-to-analog direction (towards the loop).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -24..23  

pdnPotsPortCustInfo 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.7
This object represents textual information about an user, typically user name and directory number.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pdnPotsPortG729VoiceCodec 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.8
This object is used to enable or disable G.729 codec on this POTS port.
Status: current Access: read-write
OBJECT-TYPE    
  SwitchState  

pdnPotsPortPreferedVoiceCodec 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.9
This object is the preferable voice encoding configured for this port.
Status: current Access: read-write
OBJECT-TYPE    
  VoiceEncoding  

pdnPotsPortPreferredPacketPeriod 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.10
The value of this object contains the preferred packetization period in milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..2147483647  

pdnPotsPortSilenceSuppression 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.11
This object allows users to enable or disable silence suppression. If the value of the object is 'enabled (1)' silence suppression will be performed for a call placed on this port if agreed via negotiation with the far end.
Status: current Access: read-write
OBJECT-TYPE    
  SwitchState  

pdnPotsPortActualVoiceCodec 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.12
This object is the actual voice encoding being used on this port as determined by the device in real-time. This object may differ from the configurable 'pdnPotsPortPreferedVoiceCodec' object.
Status: current Access: read-only
OBJECT-TYPE    
  VoiceEncoding  

pdnPotsPortCallElapsedTime 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.13
This value is the number of seconds that have elapsed since the start of the current call. If no active call is in progress on this port, this object should be zero.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

pdnPotsPortModemDetected 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.14
This object displays the status of the modem/fax connected on this port. If the value of this object is 'enabled (1)' the modem or fax answer tone has been detected. Otherwise this object will return 'disabled (2)'.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

pdnPotsPortEchoCanceller 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.15
This object displays the current status of the echo canceller.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

pdnPotsPortLocalEndName 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.16
This object contains a descriptive text identifying the local endpoint's name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..64)  

pdnPotsPortActiveSoftswitch 1.3.6.1.4.1.1795.2.24.2.50.1.1.1.6.1.17
This object displays the active selection for the Softswitch (e.g., Call Agent, Proxy Agent, etc.) for this Pots port. The possible values for this object are: primary --> Primary Softswitch is selected secondary --> Secondary Softswitch is selected none --> no softswitch is currently selected. The configuration of the primary/secondary softswitches are found in objects outside this document (e.g., pdnCpIwfIpMgcpPriAgentName, etc...) If the SNMP agent can not determine an active softswitch for this Pots port (e.g, lost communication with the Call Agent), the value of this object will be set to 'none (3)'.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), secondary(2), none(3)  

pdnCpIwfAal2StatsTable 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1
This table is used to maintain AAL2-Customer Part Sublayer (CPS) statistics per VCC associated to each CpIwf port. An entry in this table represents the AAL2 statistics maintained for this circuit.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PdnCpIwfAal2StatsEntry

pdnCpIwfAal2StatsEntry 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1
Contained AAL2 stats for a VCC defined on this cpIwf.
Status: current Access: not-accessible
OBJECT-TYPE    
  PdnCpIwfAal2StatsEntry  

pdnCpIwfAal2CpsRxPkts 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.1
Number of CPS Received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnCpIwfAal2CpsTxPkts 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.2
Number of CPS Transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnCpIwfAal2CpsParityErrors 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.3
Number of errors encountered as specified in Table 6/I.363.2 (errnum=0)
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnCpIwfAal2CpsSeqNumErrors 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.4
Number of errors encountered as specified in Table 6/I.363.2 (errnum=1)
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnCpIwfAal2CpsOsfMismatchErrors 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.5
Number of errors encountered as specified in Table 6/I.363.2 (errnum=2)
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnCpIwfAal2CpsOsfErrors 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.6
Number of errors encountered as specified in Table 6/I.363.2 (errnum=3)
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnCpIwfAal2CpsHecErrors 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.7
Number of errors encountered as specified in Table 6/I.363.2 (errnum=4)
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnCpIwfAal2CpsOversizeSduErrors 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.8
Number of errors encountered as specified in Table 6/I.363.2 (errnum=5)
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnCpIwfAal2CpsReassemblyErrors 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.9
Number of errors encountered as specified in Table 6/I.363.2 (errnum=6)
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnCpIwfAal2CpsHecOverlapErrors 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.10
Number of errors encountered as specified in Table 6/I.363.2 (errnum=7)
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnCpIwfAal2CpsUuiErrors 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.11
Number of errors encountered as specified in Table 6/I.363.2 (errnum=8)
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnCpIwfAal2CpsCidErrors 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.1.1.12
Number of errors encountered as specified in Table 6/I.363.2 (errnum=9)
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortStatsTable 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2
This table is used to maintain statistics per Pots port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PdnPotsPortStatsEntry

pdnPotsPortStatsEntry 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1
Contained statistics per Pots Port.
Status: current Access: not-accessible
OBJECT-TYPE    
  PdnPotsPortStatsEntry  

pdnPotsPortTotalCalls 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.1
Total Number of successfull calls performed on this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortTotalCallsFailure 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.2
Total number of calls that failed on this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortTotalCallsDropped 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.3
Total number of calls (in/out) that were dropped on this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortInCallsReceived 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.4
Total number of incoming calls received on this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortInCallsAnswered 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.5
Total number of incoming calls answered on this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortInCallsConnected 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.6
Total number of incoming calls connected on this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortInCallsFailure 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.7
Total number of incoming calls that failed on this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortOutCallsAttempted 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.8
Total number of outgoing calls that were attempted on this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortOutCallsAnswered 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.9
Total number of outgoing calls that were answered on this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortOutCallsConnected 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.10
Total number of outgoing calls that were connected on this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortOutCallsFailure 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.11
Total number of outgoing calls that failed on this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortPacketsSent 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.12
Total number of packets transmitted by this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortPacketsReceived 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.13
Total number of packets received by this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortPacketsLost 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.14
Total number of packets lost by this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortBytesSent 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.15
Total number of bytes transmitted by this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsPortBytesReceived 1.3.6.1.4.1.1795.2.24.2.50.1.1.3.2.1.16
Total number of bytes received by this POTS port.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

pdnPotsTestTable 1.3.6.1.4.1.1795.2.24.2.50.1.1.2.1
The Paradyne Pots Port Interface Test Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PdnPotsTestEntry

pdnPotsTestEntry 1.3.6.1.4.1.1795.2.24.2.50.1.1.2.1.1
An entry in the Paradyne POTS Interface Test Table. Only 1 test can be run at a time per POTS interface index (ifIndex).
Status: current Access: not-accessible
OBJECT-TYPE    
  PdnPotsTestEntry  

pdnPotsTestType 1.3.6.1.4.1.1795.2.24.2.50.1.1.2.1.1.1
This object is used to specify the test type in this interface. If no test is active on this port, the agent should return the value of 'noTest (1)'
Status: current Access: read-write
OBJECT-TYPE    
  PdnPotsTestTypes  

pdnPotsTestCmd 1.3.6.1.4.1.1795.2.24.2.50.1.1.2.1.1.2
This object can be set to initiate and/or terminate the test running on this interface. If no test is 'active' on this interface, the agent should return the value of 'noOp(1)'. Only if a test is 'active' on this interface, the agent should process a 'keepAlive (4)' command. Otherwise, this command should be rejected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noOp(1), start(2), stop(3), keepAlive(4)  

pdnPotsTestStatus 1.3.6.1.4.1.1795.2.24.2.50.1.1.2.1.1.3
This object displays the current status of this entry. If no test is running on this interface, the agent should return the value 'inactive (2)'.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER active(1), inactive(2)  

pdnCpIwfMIBCompliances 1.3.6.1.4.1.1795.2.24.2.50.1.2.1
OBJECT IDENTIFIER    

pdnCpIwfMIBGroups 1.3.6.1.4.1.1795.2.24.2.50.1.2.2
OBJECT IDENTIFIER    

pdnCpIwfMIBCompliance 1.3.6.1.4.1.1795.2.24.2.50.1.2.1.1
The compliance statement for SNMP entities that support LES as specified in af-vmoa-0145.000 of the ATM Forum. This compliance has been deprecated and replaced by V2 below.
Status: deprecated Access: read-only
MODULE-COMPLIANCE    

pdnCpIwfMIBComplianceV2 1.3.6.1.4.1.1795.2.24.2.50.1.2.1.2
The compliance statement for SNMP entities that support LES as specified in af-vmoa-0145.000 of the ATM Forum. This compliance statement superseeds the pdnCpIwfMIBCompliance. This compliance has been deprecated and replaced by V3 below.
Status: deprecated Access: read-only
MODULE-COMPLIANCE    

pdnCpIwfMIBComplianceV3 1.3.6.1.4.1.1795.2.24.2.50.1.2.1.3
The compliance statement for SNMP entities that support LES as specified in af-vmoa-0145.000 of the ATM Forum. This compliance statement superseeds the pdnCpIwfMIBComplianceV2.
Status: current Access: read-only
MODULE-COMPLIANCE    

pdnCpIwfGeneralConfigGroup 1.3.6.1.4.1.1795.2.24.2.50.1.2.2.1
General Configuration of CpIwf ports
Status: deprecated Access: read-only
OBJECT-GROUP    

pdnCpIwfPotsPortConfigGroup 1.3.6.1.4.1.1795.2.24.2.50.1.2.2.2
Configuration group for Pots ports This group is now deprecated by pdnCpIwfPotsPortConfigGroupV2.
Status: deprecated Access: read-only
OBJECT-GROUP    

pdnCpIwfAal2StatsGroup 1.3.6.1.4.1.1795.2.24.2.50.1.2.2.3
Aal2 stats per CpIwf
Status: current Access: read-only
OBJECT-GROUP    

pdnCpIwfPotsPortStatsGroup 1.3.6.1.4.1.1795.2.24.2.50.1.2.2.4
Pots Ports stats group
Status: deprecated Access: read-only
OBJECT-GROUP    

pdnCpIwfGeneralConfigGroupV2 1.3.6.1.4.1.1795.2.24.2.50.1.2.2.5
Configuration of general parameters related to the CpIwf. This group superseeds the pdnCpIwfGeneralConfigGroup which was splitted in two groups.
Status: current Access: read-only
OBJECT-GROUP    

pdnCpIwfIADConfigGroupV2 1.3.6.1.4.1.1795.2.24.2.50.1.2.2.6
Configuration of each CpIwf interfaces in the device. This group superseeds the pdnCpIwfGeneralConfigGroup which was splitted in two groups. This group is now deprecated by pdnCpIwfPotsPortConfigGroupV3.
Status: current Access: read-only
OBJECT-GROUP    

pdnCpIwfPotsPortStatsGroupV2 1.3.6.1.4.1.1795.2.24.2.50.1.2.2.7
Pots Ports stats group
Status: current Access: read-only
OBJECT-GROUP    

pdnCpIwfPotsPortConfigGroupV2 1.3.6.1.4.1.1795.2.24.2.50.1.2.2.8
Configuration group for Pots ports
Status: current Access: read-only
OBJECT-GROUP    

pdnCpIwfPotsPortTestGroupV2 1.3.6.1.4.1.1795.2.24.2.50.1.2.2.9
Pots Ports test group
Status: current Access: read-only
OBJECT-GROUP    

pdnCpIwfIADConfigGroupV3 1.3.6.1.4.1.1795.2.24.2.50.1.2.2.10
Configuration of each CpIwf interfaces in the device. This group superseeds the pdnCpIwfGeneralConfigGroupV2.
Status: current Access: read-only
OBJECT-GROUP    

pdnCpIwfPotsPortPacketStatsGroup 1.3.6.1.4.1.1795.2.24.2.50.1.2.2.11
Pots Ports packet statistics group
Status: current Access: read-only
OBJECT-GROUP