PDN-DS1EXT-MIB
File:
PDN-DS1EXT-MIB.mib (7645 bytes)
Imported modules
Imported symbols
Defined Types
PdnDs1ExtConfEntry |
|
SEQUENCE |
|
|
|
|
pdnDs1ExtConfLineLengthType |
INTEGER |
|
|
pdnDs1ExtConfLineLength |
INTEGER |
|
|
pdnDs1ExtConfLineBuildOut |
INTEGER |
|
|
pdnDs1ExtConfConnector |
INTEGER |
|
Defined Values
pdnDs1Ext |
1.3.6.1.4.1.1795.2.24.2.6.5.5 |
The Paradyne enterprise DS1/G.703 extension MIB.
This MIB provides additional DS1 and G.703 (E1) configuration
objects not provided by rfc2495. |
MODULE-IDENTITY |
|
|
|
pdnDs1ExtConfTable |
1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1 |
The Paradyne DS1/G.703 extension configuration table.
This table is used for configuring extensions to DS1
and G.703 interfaces. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PdnDs1ExtConfEntry |
|
pdnDs1ExtConfEntry |
1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1 |
An entry in the Paradyne DS1/G.703 extension configuration table.
Note: The objects used depend on the type of interface.
For DS1: use pdnDs1ExtConfLineLengthType and one of
(pdnDs1ExtConfLineLength or pdnDs1ExtConfLineBuildOut)
For G.703: use pdnDs1ExtConfLineLengthType and pdnDs1ExtConfConnector
|
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PdnDs1ExtConfEntry |
|
|
pdnDs1ExtConfLineLengthType |
1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.1 |
This entry specifies the type of loop length for the interface.
short-haul is intended for intra-building use.
long-haul is intended for inter-building use. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
shortHaul(1), longHaul(2) |
|
pdnDs1ExtConfLineLength |
1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.2 |
This entry specifies the loop length, in feet, for a short-haul
DS1 line. This object only applies to DS1 interfaces.
Note: This object shares a mutually exclusive relationship
with the pdnDs1ExtConfLineBuildOut object i.e. only one of the
two can be used for configuration at one time, based on the
pdnDs1ExtConfLineLengthType object. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
feet000To133(1), feet134To266(2), feet267To399(3), feet400To533(4), feet534To655(5) |
|
pdnDs1ExtConfLineBuildOut |
1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.3 |
This entry specifies the line build out, in decibels, for a
long-haul DS1 line.
dB0Pnt0 = 0.0 dB
dB7Pnt5 = -7.5 dB
dB15Pnt0 = -15.0 dB
dB22Pnt5 = -22.5 dB
This object only applies to DS1 interfaces.
Note: This object shares a mutually exclusive relationship
with the pdnDs1ExtConfLineLength object i.e. only one of the
two can be used for configuration at one time, based on the
pdnDs1ExtConfLineLengthType object. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
dB0Pnt0(1), dB7Pnt5(2), dB15Pnt0(3), dB22Pnt5(4) |
|
pdnDs1ExtConfConnector |
1.3.6.1.4.1.1795.2.24.2.6.5.5.1.1.1.4 |
This entry specifies the type of connector to be used.
This object only applies to G.703 interfaces.
bnc: 75-Ohm connector supporting only short-haul.
rj48: 120-Ohm connector supporting both short-haul and long-haul. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
bnc(1), rj48(2) |
|
pdnDs1ExtCompliance |
1.3.6.1.4.1.1795.2.24.2.6.5.5.2.2.1 |
Compliance statement for using this MIB for configuring
DS1 interfaces. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
pdnDs1ExtG703Compliance |
1.3.6.1.4.1.1795.2.24.2.6.5.5.2.2.2 |
Compliance statement for using this MIB for configuring
G.703 interfaces. |
Status: current |
Access: read-only |
MODULE-COMPLIANCE |
|
|
|
pdnDs1ExtT1ConfigGroup |
1.3.6.1.4.1.1795.2.24.2.6.5.5.2.1.1 |
A collection of configuration objects required
for configuring a T1 interface. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|
pdnDs1ExtE1ConfigGroup |
1.3.6.1.4.1.1795.2.24.2.6.5.5.2.1.2 |
A collection of configuration objects required
for configuring a G.703 (E1) interface. |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|