PEGASUS-SDH-MIB

File: PEGASUS-SDH-MIB.mib (33321 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC IF-MIB
PEGASUS-MIB

Imported symbols

Integer32 OBJECT-TYPE MODULE-IDENTITY
TEXTUAL-CONVENTION DisplayString TruthValue
InterfaceIndex InterfaceIndexOrZero ifIndex
pegasusMibModule OperStateEnum AvailabilityStatusElem
CommStateEnum

Defined Types

ClockSourceEnum  
INTEGER rxLineClock(1), referenceClock(2), freeRun(3)    

ClockSyncStateEnum  
INTEGER syncOk(1), syncNotOk(2)    

ClockModeEnum  
INTEGER enabled(1), disabled(2)    

ClockPriorityEnum  
INTEGER primary(1), secondary(2)    

ClockQualityEnum  
INTEGER prc(1), ssu-a(2), ssu-b(3), sec(4), dnu(5), auto(6), unknown(7)    

ClockStateEnum  
INTEGER invalid(1), valid(2)    

MultiplexingModeEnum  
INTEGER au3(1), au4(2)    

VirtualContainerTypeEnum  
INTEGER vc4(1), vc3(2), vc12(3)    

LaserOperationModeEnum  
INTEGER off(1), als(2)    

LaserStateEnum  
INTEGER on(1), shutdown(2), restart(3)    

SdhInterfaceEnum  
INTEGER optical(1), e1(2)    

PRBSPatternEnum  
INTEGER pattern2exp15(1), pattern2exp20(2)    

TraceSizeEnum  
INTEGER size1byte(1), size16byte(2)    

SignalLabel  
Representation of a VC Signal Label. The meaning of the SignalLabel depends on the type of vitual container. VC-12s use the following values: 001b Unequipped 001b Equipped (non specific) 010b Asynchronous 011b Bit Synchronous 100b Byte Synchronous 101b Reserved for future use 110b Test signal (O.181) 111b VC-AIS VC-4 and VC-3 use these values: 00h Unequipped or supervisory-unequipped 01h Equipped - non-specific 02h TUG Structure 03h Locked TU-n 04h Asynch. mapping of 34'386/44'736 kbit/s into Container-3 12h Asynch. mapping of 139'264 kbit/s into Container-4 13h ATM Mapping 14h MAN DQDB (IEEE 802.6 mapping 15h FDDI (ISO 9314) mapping 16h Mapping of HDLC/PPP framed signal 17h Mapping of SDL with SDH self synch. Scrambler 18h Mapping of HDLC/LAP-S framed signals 19h Mapping of SDL with set-reset scrambler 1Ah Mapping of 10 Gbit/s Ethernet frames (IEEE 802.3) CFh Obsolete mapping of HDLC/PPP framed signal E1h-FCh Reserved for national use FEh Test signal, O.181 specific mapping FFh VC-AIS
TEXTUAL-CONVENTION    
  INTEGER 0..7 | 18..26 | 207 | 225..252 | 254..255  

ConcatenationTypeEnum  
INTEGER lcas(1), nonLCAS(2)    

EthernetIfEncapsulationEnum  
INTEGER disabled(1), gfp(2), lapf(3), laps(4), ppp(5)    

OrderLevelEnum  
INTEGER highOrder(1), lowOrder(2)    

STM1SlotNumber  
INTEGER 2    

TUGIndex  
INTEGER 1..3    

TUGIndexOrZero  
INTEGER 0..3    

Stm1CardEntry  
SEQUENCE    
  stm1CardSlotNumber STM1SlotNumber
  stm1CardName DisplayString
  stm1CardHardwareVersion DisplayString
  stm1CardFirmwareVersion DisplayString
  stm1CardManufacturer DisplayString
  stm1CardSerialNumber DisplayString
  stm1CardMultiplexingMode MultiplexingModeEnum
  stm1CardJ0TraceMonitoring OperStateEnum
  stm1CardJ1TraceMonitoring OperStateEnum
  stm1CardJ2TraceMonitoring OperStateEnum
  stm1CardJ0PathTraceSize TraceSizeEnum
  stm1CardJ0PathTraceSend DisplayString
  stm1CardJ0PathTraceExpected DisplayString
  stm1CardJ0PathTraceReceive DisplayString
  stm1CardLaserOperationMode LaserOperationModeEnum
  stm1CardLaserState LaserStateEnum
  stm1CardOperState OperStateEnum
  stm1CardAvailabilityState AvailabilityStatusElem
  stm1CardMgmtCommState CommStateEnum
  stm1CardPRBSGeneratorSink SdhInterfaceEnum
  stm1CardPRBSAnalyzerSource SdhInterfaceEnum
  stm1CardPRBSPattern PRBSPatternEnum
  stm1CardAlarmStatus Integer32

Stm1CardClockEntry  
SEQUENCE    
  stm1CardActiveClockSource ClockSourceEnum
  stm1CardClockSyncState ClockSyncStateEnum
  stm1CardTxLineClockQuality ClockQualityEnum
  stm1CardRxClockMode ClockModeEnum
  stm1CardRxClockPriority ClockPriorityEnum
  stm1CardRxClockQuality ClockQualityEnum
  stm1CardRxClockState ClockStateEnum
  stm1CardReferenceClockMode ClockModeEnum
  stm1CardReferenceClockPriority ClockPriorityEnum
  stm1CardReferenceClockQuality ClockQualityEnum
  stm1CardReferenceClockState ClockStateEnum

EthernetIfEntry  
SEQUENCE    
  etherIfConcatenationOption ConcatenationTypeEnum
  etherIfEncapsulation EthernetIfEncapsulationEnum
  etherIfOrderLevel OrderLevelEnum
  etherIfAlarmStatus Integer32

VcEntry  
SEQUENCE    
  vcType VirtualContainerTypeEnum
  vcRelatedTUG TUGIndexOrZero
  vcRelatedVC InterfaceIndexOrZero
  vcAssignedIfIndex InterfaceIndexOrZero
  vcPathTraceSend DisplayString
  vcPathTraceExpected DisplayString
  vcPathTraceReceive DisplayString
  vcSignalLabelSend SignalLabel
  vcSignalLabelExpected SignalLabel
  vcSignalLabelReceive SignalLabel
  vcAlarmStatus Integer32

TugConfigEntry  
SEQUENCE    
  tugIndex TUGIndex
  tugRelatedVC4 InterfaceIndex
  tugOrderLevel OrderLevelEnum

Defined Values

pegasusSdhMibModule 1.3.6.1.4.1.6368.2.8
This MIB applies to the PEGASUS SDSL product manufactured by Schmid Telecom Zurich. The MIB is modelled after the PEM management model, so object hierarchy and individual variables agree with the PEM client. This MIB represents an extension to the DS1-MIB and the SONET-MIB. These three MIB files are used to manage the PEGASUS STM-1 card. The PEGASUS-SDH-MIB contains five tables: - stm1CardTable one entry for each STM-1 card configured. - stm1CardClockTable one entry for each STM-1 card configured. - ethernetIfTable one entry for each Ethernet interface of a configured STM-1 card. - vcTable one entry for each Virtual Container (VC-3/4/12). - tugConfigTable one entry for each Tributary Unit Group (TUG-3). Note - The tables that represent extensions to the DS1-/SINET-MIB use the ifIndex from IF-MIB (ifTable).
MODULE-IDENTITY    

stm1CardTable 1.3.6.1.4.1.6368.2.8.1
A table containing stm1 card specific information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Stm1CardEntry

stm1CardEntry 1.3.6.1.4.1.6368.2.8.1.1
Row and index definition for stm1 card table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Stm1CardEntry  

stm1CardSlotNumber 1.3.6.1.4.1.6368.2.8.1.1.1
Slot number for stm1 card.
Status: current Access: not-accessible
OBJECT-TYPE    
  STM1SlotNumber  

stm1CardName 1.3.6.1.4.1.6368.2.8.1.1.2
Name of the PEGASUS device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

stm1CardHardwareVersion 1.3.6.1.4.1.6368.2.8.1.1.3
Hardware version of the STM-1 card. This is also called CHM-number (it always starts with the letters 'CHM'). The number '404' after 'CHM' identifies the card as a STM-1 card.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

stm1CardFirmwareVersion 1.3.6.1.4.1.6368.2.8.1.1.4
Version number and build date of the firmware running on the line card. The format is 'major.minor YYYYMMDD hh:mm'.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

stm1CardManufacturer 1.3.6.1.4.1.6368.2.8.1.1.5
Manufacturer of the STM-1 card.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

stm1CardSerialNumber 1.3.6.1.4.1.6368.2.8.1.1.6
Serial number of the line card. Also called HM-number, as it always starts with 'HM'. Example: HMVSS014810294.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

stm1CardMultiplexingMode 1.3.6.1.4.1.6368.2.8.1.1.7
Selects the SDH multiplexing mode. Either it is STM1-AU3-VC3 or STM1-AU4-VC4.
Status: current Access: read-write
OBJECT-TYPE    
  MultiplexingModeEnum  

stm1CardJ0TraceMonitoring 1.3.6.1.4.1.6368.2.8.1.1.8
If trace monitoring is disable no alarm is propagated to PEM and also no RDI/AIS is inserted.
Status: current Access: read-write
OBJECT-TYPE    
  OperStateEnum  

stm1CardJ1TraceMonitoring 1.3.6.1.4.1.6368.2.8.1.1.9
If trace monitoring is disable no alarm is propagated to PEM and also no RDI/AIS is inserted.
Status: current Access: read-write
OBJECT-TYPE    
  OperStateEnum  

stm1CardJ2TraceMonitoring 1.3.6.1.4.1.6368.2.8.1.1.10
If trace monitoring is disable no alarm is propagated to PEM and also no RDI/AIS is inserted.
Status: current Access: read-write
OBJECT-TYPE    
  OperStateEnum  

stm1CardJ0PathTraceSize 1.3.6.1.4.1.6368.2.8.1.1.11
Size of the Regenerator Section Trace Message.
Status: current Access: read-write
OBJECT-TYPE    
  TraceSizeEnum  

stm1CardJ0PathTraceSend 1.3.6.1.4.1.6368.2.8.1.1.12
Configurable Regenerator Section (RS) Trace Message.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

stm1CardJ0PathTraceExpected 1.3.6.1.4.1.6368.2.8.1.1.13
Regenerator Section (RS) Trace Message that should be received.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

stm1CardJ0PathTraceReceive 1.3.6.1.4.1.6368.2.8.1.1.14
Regenerator Section (RS) Trace Message that is be received.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

stm1CardLaserOperationMode 1.3.6.1.4.1.6368.2.8.1.1.15
Configuration of the 'Automatic Laser Shutdown' feature.
Status: current Access: read-write
OBJECT-TYPE    
  LaserOperationModeEnum  

stm1CardLaserState 1.3.6.1.4.1.6368.2.8.1.1.16
Actual state of the laser.
Status: current Access: read-only
OBJECT-TYPE    
  LaserStateEnum  

stm1CardOperState 1.3.6.1.4.1.6368.2.8.1.1.17
The operational state is a status property indicating whether or not a device is physically installed and working. enabled The device is partially or fully operable and available for use. disabled The device is totally inoperable and unavailable to provide service.
Status: current Access: read-only
OBJECT-TYPE    
  OperStateEnum  

stm1CardAvailabilityState 1.3.6.1.4.1.6368.2.8.1.1.18
The availability status gives more detailed information about failures within a device. An empty status set means that no error exists. Possible status are: in test The device is under test. failed The device has an internal fault that prevents it from operating. power off The device requires power to be applied and is not powered on. off line The device requires a routine operation to be performed to place it online and make it available for use. off duty The device has been made inactive by an internal control process in accordance with a predetermined time schedule. dependency The device can not operate because some other resource on which it depends is unavailable. degraded The device is partially defective but still operable. not installed The device is not present, or incomplete. log full The log is full.
Status: current Access: read-only
OBJECT-TYPE    
  AvailabilityStatusElem  

stm1CardMgmtCommState 1.3.6.1.4.1.6368.2.8.1.1.19
The Management Comm State indicates the state of the management connection between the PEM Server and the STM-1 card. disconnected No connection has been established. init A connection has freshly been established on the underlying protocol, but no management information has been transmitted so far. identification The connected device is being identified. check hardware The connected hardware is compared to the one stored in the configuration. hardware adaptation If the configured and the existing device do not match, an adoption is made. The behaviour in this case can be configured with the 'HW Adaptation Policy' option. check program version The program version of the connected hardware is compared to the one stored in the configuration. check config version The configuration version of the connected hardware is compared to the one stored in the configuration. download config If a configuration version mismatch has been detected and the 'Config Priority' of 'PEGASUS system' is set to 'Device', the configuration is downloaded from the device to the PEM Server. upload config If a configuration version mismatch has been detected and the 'Config Priority' of 'PEGASUS system' is set to 'Server', the configuration is uploaded from the PEM Server to the device. status synch The values of the status properties are being synchronised. resetting The device is resetting. inactive The device is connected, but it is inactive, that is not operational. This may be due to a hardware mismatch. active The management connection between the device and the PEM Server is fully established and the device is active.
Status: current Access: read-only
OBJECT-TYPE    
  CommStateEnum  

stm1CardPRBSGeneratorSink 1.3.6.1.4.1.6368.2.8.1.1.20
Determines, whether the PRBS Generator should be used on the optical or on the E1 links.
Status: current Access: read-write
OBJECT-TYPE    
  SdhInterfaceEnum  

stm1CardPRBSAnalyzerSource 1.3.6.1.4.1.6368.2.8.1.1.21
Determines, whether the PRBS Analyzer should be used on the optical or on the E1 links.
Status: current Access: read-write
OBJECT-TYPE    
  SdhInterfaceEnum  

stm1CardPRBSPattern 1.3.6.1.4.1.6368.2.8.1.1.22
Determines the PRBS Pattern to be used.
Status: current Access: read-write
OBJECT-TYPE    
  PRBSPatternEnum  

stm1CardAlarmStatus 1.3.6.1.4.1.6368.2.8.1.1.23
This variable indicates the status of STM-1 card, regenerator section and multiplex section. It's a bitmap represented as a sum. Therefore multiple alarms can be displayed simultaneously. The value noAlarm is only set if there isn't any alarm active. The various bit positions are: 1 No alarm present -- STM-1 card -- 2 Initialization failure 4 Firmware Version Mismatch 8 Maintenance -- regenerator section RS -- 16 Loss of Signal (LOS) 32 Loss of Frame (LOF) 64 Trace ID Mismatch (RS-TIM) -- multiplex section MS -- 128 Alarm Indication Signal (MS-AIS) 256 Remote Defect Indication (MS-RDI, former FERF)
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..511  

stm1CardClockTable 1.3.6.1.4.1.6368.2.8.2
A table containing stm1 card specific clock information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Stm1CardClockEntry

stm1CardClockEntry 1.3.6.1.4.1.6368.2.8.2.1
Row and index definition for stm1 card clock table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Stm1CardClockEntry  

stm1CardActiveClockSource 1.3.6.1.4.1.6368.2.8.2.1.1
Displays which clock sourceis active and used as sync source.
Status: current Access: read-only
OBJECT-TYPE    
  ClockSourceEnum  

stm1CardClockSyncState 1.3.6.1.4.1.6368.2.8.2.1.2
Sync status is OK if RX or Reference clock is valid and used as active sync source.
Status: current Access: read-only
OBJECT-TYPE    
  ClockSyncStateEnum  

stm1CardTxLineClockQuality 1.3.6.1.4.1.6368.2.8.2.1.3
This is the clock quality of the outgoing SDH signal. The default sets the outgoing quality to the incoming quality. Sometime it may be useful to set a fix outgoing quality.
Status: current Access: read-write
OBJECT-TYPE    
  ClockQualityEnum  

stm1CardRxClockMode 1.3.6.1.4.1.6368.2.8.2.1.4
If enabled the RX line clock can be used as sync source.
Status: current Access: read-write
OBJECT-TYPE    
  ClockModeEnum  

stm1CardRxClockPriority 1.3.6.1.4.1.6368.2.8.2.1.5
This value has always the opposite value of Reference Clock Priority.
Status: current Access: read-write
OBJECT-TYPE    
  ClockPriorityEnum  

stm1CardRxClockQuality 1.3.6.1.4.1.6368.2.8.2.1.6
This is the clock quality of the incoming SDH signal.
Status: current Access: read-only
OBJECT-TYPE    
  ClockQualityEnum  

stm1CardRxClockState 1.3.6.1.4.1.6368.2.8.2.1.7
Clock status is valid if a good clock can be found on input (clock checker).
Status: current Access: read-only
OBJECT-TYPE    
  ClockStateEnum  

stm1CardReferenceClockMode 1.3.6.1.4.1.6368.2.8.2.1.8
If enabled the Reference clock (V5 card input) can be used as sync source.
Status: current Access: read-write
OBJECT-TYPE    
  ClockModeEnum  

stm1CardReferenceClockPriority 1.3.6.1.4.1.6368.2.8.2.1.9
This value has always the opposite value of Rx Clock Priority.
Status: current Access: read-write
OBJECT-TYPE    
  ClockPriorityEnum  

stm1CardReferenceClockQuality 1.3.6.1.4.1.6368.2.8.2.1.10
Defines the quality of the reference clock input. This value will be transmitted in SDH-TX if reference clock is used as active sync source.
Status: current Access: read-write
OBJECT-TYPE    
  ClockQualityEnum  

stm1CardReferenceClockState 1.3.6.1.4.1.6368.2.8.2.1.11
Clock status is valid if a good clock can be found on input (clock checker).
Status: current Access: read-only
OBJECT-TYPE    
  ClockStateEnum  

ethernetIfTable 1.3.6.1.4.1.6368.2.8.3
This table contains additional information concerning the ethernet interfaces of a STM-1 card. It represents an extension of the if(X)Table (see IF-MIB).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EthernetIfEntry

ethernetIfEntry 1.3.6.1.4.1.6368.2.8.3.1
Row and index definition for the ethernetIfTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  EthernetIfEntry  

etherIfConcatenationOption 1.3.6.1.4.1.6368.2.8.3.1.1
Configuration of the Link Capacity Adjustment Scheme.
Status: current Access: read-write
OBJECT-TYPE    
  ConcatenationTypeEnum  

etherIfEncapsulation 1.3.6.1.4.1.6368.2.8.3.1.2
This attribute shows the used Ethernet encapsulation protocol.
Status: current Access: read-only
OBJECT-TYPE    
  EthernetIfEncapsulationEnum  

etherIfOrderLevel 1.3.6.1.4.1.6368.2.8.3.1.3
Only relevant, if SDH Multiplexing Mode (see STM-1 card propertied) is set to VC3.
Status: current Access: read-only
OBJECT-TYPE    
  OrderLevelEnum  

etherIfAlarmStatus 1.3.6.1.4.1.6368.2.8.3.1.4
This variable indicates the status of an Ethernet Interface. It's a bitmap represented as a sum. Therefore multiple defects can be displayed simultaneously. The value noAlarm is only set if there isn't any alarm. The various bit positions are (LO = LowOrder, HO = HighOrder): 1 No alarm 2 LO LCAS group identifier mismatch (Rx) 4 HO LCAS group identifier mismatch (Rx) 8 LO VCG exceeds max. differential delay (Rx) 16 HO VCG exceeds max. differential delay (Rx) 32 LO VCG exceeds max. differential delay, calculated over all containers (Rx) 64 HO VCG exceeds max. differential delay, calculated over all containers (Rx) 128 Transmit FIFO overflow (Tx) 256 Rx head-of-line blocking FIFO overflow
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..511  

vcTable 1.3.6.1.4.1.6368.2.8.4
This table contains additional information for VC concerning the multiplexing configuration. It's an extension of the ifTable (IF-MIB) and the tables of the SONET/SDH-MIB.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VcEntry

vcEntry 1.3.6.1.4.1.6368.2.8.4.1
Row and index definition for the vcConfigTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  VcEntry  

vcType 1.3.6.1.4.1.6368.2.8.4.1.1
Type of Virtual Container (VC). In Pegasus VC-4, VC-3 or VC-12.
Status: current Access: read-only
OBJECT-TYPE    
  VirtualContainerTypeEnum  

vcRelatedTUG 1.3.6.1.4.1.6368.2.8.4.1.2
Represents the index of the Tributary Unit Group within the tugConfigTable to which this VC is assigned to. The value depends also on the multiplexing mode. If the value is 0, there doesn't exist the relation VC-x to TUG-3. Possible values: 1) multiplexing mode = AU-4: VC-4: vcRelatedTUG = 0 VC-3/12: vcRelatedTUG = 1..3 2) multiplexing mode = AU-3: vcRelatedTUG = 0 (no dependency on VC type)
Status: current Access: read-only
OBJECT-TYPE    
  TUGIndexOrZero  

vcRelatedVC 1.3.6.1.4.1.6368.2.8.4.1.3
Represents the index of the Virtual Container within the ifTable to which this VC is assigned to. The value depends also on the multiplexing mode. If the value is 0, there doesn't exist the relation VC-x to VC-x. Possible values: 1) multiplexing mode = AU-4: vcRelatedVC = 0 (no dependency on VC type) 2) multiplexing mode = AU-3: VC-3: vcRelatedVC = 0 VC-12: vcRelatedVC = 2031..2033 (example for slot 2)
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndexOrZero  

vcAssignedIfIndex 1.3.6.1.4.1.6368.2.8.4.1.4
Represents the index of the interface within the ifTable (IF-MIB) that transmits to this VC.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndexOrZero  

vcPathTraceSend 1.3.6.1.4.1.6368.2.8.4.1.5
The value of the outgoing J1 Byte VC Path Trace byte message.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

vcPathTraceExpected 1.3.6.1.4.1.6368.2.8.4.1.6
The value of the expected J1 Byte VC Path Trace byte message.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

vcPathTraceReceive 1.3.6.1.4.1.6368.2.8.4.1.7
The value of the incoming J1 Byte VC Path Trace byte message.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vcSignalLabelSend 1.3.6.1.4.1.6368.2.8.4.1.8
The outgoing C2 VC Signal Label (0x02 = TUG structure).
Status: current Access: read-write
OBJECT-TYPE    
  SignalLabel  

vcSignalLabelExpected 1.3.6.1.4.1.6368.2.8.4.1.9
The expected C2 VC Signal Label (0x02 = TUG structure).
Status: current Access: read-write
OBJECT-TYPE    
  SignalLabel  

vcSignalLabelReceive 1.3.6.1.4.1.6368.2.8.4.1.10
The incoming C2 VC Signal Label (0x02 = TUG structure).
Status: current Access: read-only
OBJECT-TYPE    
  SignalLabel  

vcAlarmStatus 1.3.6.1.4.1.6368.2.8.4.1.11
This variable indicates the status of the VC. It's a bitmap represented as a sum. Therefore multiple defects can be displayed simultaneously. The value noDefect should only be set if there is no other defect. Some alarms can't occur actually. The various bit positions are: 1 vcNoDefect 2 vcAlarmAIS 4 vcAlarmLOP 8 vcAlarmRDI 16 vcAlarmUnequipped 32 vcAlarmPLM 64 vcAlarmTIM 128 vcAlarmLOM 256 vcAlarmRFI 512 vcgTxAddTimeout -- not used (deprecated) 1024 vcgTxAdd -- not used (deprecated) 2048 vcgTxRemove -- not used (deprecated) 4096 vcgTxDnu -- not used (deprecated) 8192 vcgDnuOk -- not used (deprecated) 16384 vcgRxAdd -- not used (deprecated) 32768 vcgRxRemove -- not used (deprecated) 65536 vcgRxFail -- not used (deprecated) 131072 vcgLcasCrcError 262144 vcgNonLcasSeqError
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..524287  

tugConfigTable 1.3.6.1.4.1.6368.2.8.5
This table contains information concerning Tributary Unit Groups. If AU-3 structure is used, this table is empty.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TugConfigEntry

tugConfigEntry 1.3.6.1.4.1.6368.2.8.5.1
Row and index definition for the tugConfigTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  TugConfigEntry  

tugIndex 1.3.6.1.4.1.6368.2.8.5.1.1
Number of the TUG. Range 1..3
Status: current Access: not-accessible
OBJECT-TYPE    
  TUGIndex  

tugRelatedVC4 1.3.6.1.4.1.6368.2.8.5.1.2
Tok_String
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

tugOrderLevel 1.3.6.1.4.1.6368.2.8.5.1.3
Individual Order Level of this TUG. If high order is used, the TUG has exactly one VC-3 and no VC-12s. If low order is used, the TUG has exactly 21 VC-12 and no VC-3.
Status: current Access: read-write
OBJECT-TYPE    
  OrderLevelEnum  

sdhMibRevision 1.3.6.1.4.1.6368.2.8.6
The version number assigned by the version control system. You can query this from the agent, to find out with which version of the MIB was built into the agent. The value is also present in copies of the MIB to feed into SNMP managers. Comparing the version numbers from both sources can help to detect mismatches. The revision string for this version is: : PEGASUS-SDH-MIB.txt $ : 14 $ : 3/18/04 6:40p $
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString