PERIBIT-COMMON-MIB

File: PERIBIT-COMMON-MIB.mib (11311 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC PERIBIT-GLOBAL-TC
PERIBIT-GLOBAL-REG

Imported symbols

MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE
NOTIFICATION-TYPE Integer32 DisplayString
TruthValue TcChassisType pnModules
pnCommonMib

Defined Values

pnCommonMibModule 1.3.6.1.4.1.8239.1.1.3
A MIB module containing definitions of managed objects implemented by all Peribit Networks' products.
MODULE-IDENTITY    

pnCommonConfMib 1.3.6.1.4.1.8239.2.1.1
Sub-tree for Sequence Reducer MIB conformance statements.
Status: current Access: read-only
OBJECT-IDENTITY    

pnCommonObjs 1.3.6.1.4.1.8239.2.1.2
Sub-tree for common MIB objects.
Status: current Access: read-only
OBJECT-IDENTITY    

pnCommonEvents 1.3.6.1.4.1.8239.2.1.3
Sub-tree for common MIB events.
Status: current Access: read-only
OBJECT-IDENTITY    

pnSys 1.3.6.1.4.1.8239.2.1.2.1
Sub-tree for common system objects.
Status: current Access: read-only
OBJECT-IDENTITY    

pnChassis 1.3.6.1.4.1.8239.2.1.2.2
Sub-tree for common chassis information.
Status: current Access: read-only
OBJECT-IDENTITY    

pnSysSwVersion 1.3.6.1.4.1.8239.2.1.2.1.1
Full software version. The first two components of the full version are the major and minor versions. The third component indicates the maintenance release number and the fourth, the build number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

pnSysHwVersion 1.3.6.1.4.1.8239.2.1.2.1.2
Hardware version of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

pnSysSerialNumber 1.3.6.1.4.1.8239.2.1.2.1.3
The serial number of the unit. If not available, an empty string is returned.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..128)  

pnSysTimeZoneOffset 1.3.6.1.4.1.8239.2.1.2.1.4
The offset in seconds from UTC of the system's time zone. Values are negative for locations west of UTC and positive for locations east of UTC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

pnSysDaylightSaving 1.3.6.1.4.1.8239.2.1.2.1.5
Whether daylight savings are currently in effect for the system's time zone.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

pnChassisType 1.3.6.1.4.1.8239.2.1.2.2.1
Chassis type for this Peribit device.
Status: current Access: read-only
OBJECT-TYPE    
  TcChassisType  

pnCommonEventObjs 1.3.6.1.4.1.8239.2.1.3.1
Branch for objects meant only to be sent in event varbinds.
Status: current Access: read-only
OBJECT-IDENTITY    

pnCommonEventEvents 1.3.6.1.4.1.8239.2.1.3.2
Branch for the events themselves.
Status: current Access: read-only
OBJECT-IDENTITY    

pnCommonEventEventsV2 1.3.6.1.4.1.8239.2.1.3.2.0
Branch for SNMPv2 events. The OIDs for SNMPv2 events should have a zero as the next-to-last sub-identifier (as specified in RFC1902).
Status: current Access: read-only
OBJECT-IDENTITY    

pnCommonEventDescr 1.3.6.1.4.1.8239.2.1.3.1.1
String that provides a textual description of the event.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

pnCommonEventInFailSafeMode 1.3.6.1.4.1.8239.2.1.3.2.0.1
This trap is sent when the device boots up in fail-safe mode. This can happen for one of the following reasons: o Fail-safe reboot was explicitly initiated by the user. o The device rebooted automatically too many times because of the failure of internal consistency checks or the failure of tests that verify proper operation of the device.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventPowerSupplyFailure 1.3.6.1.4.1.8239.2.1.3.2.0.2
One or more sources of power to the system has failed. A redundant power-supply has presumably taken over. NOTE: This trap is for future use. Peribit devices currently do not generate this trap.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventPowerSupplyOk 1.3.6.1.4.1.8239.2.1.3.2.0.3
One or more previously failed sources of power is now working normally. The transition to normal condition happened without the system having to be restarted. NOTE: This trap is for future use. Peribit devices currently do not generate this trap.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventLicenseExpired 1.3.6.1.4.1.8239.2.1.3.2.0.4
The license for the system expired. As a result, the system will switch over to and stay in pass-through mode.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventThruputLimitExceeded 1.3.6.1.4.1.8239.2.1.3.2.0.5
The throughput of traffic through the device has exceeded the limit for which it has been licensed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventLicenseWillExpire 1.3.6.1.4.1.8239.2.1.3.2.0.6
The license for the system is about to expire shortly. When it eventually does expire, the system will switch over to and stay in pass-through mode.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventLoginFailure 1.3.6.1.4.1.8239.2.1.3.2.0.7
A user's login attempt via the console/ssh/web server failed due to incorrect username or password.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventFaultTolerantPassThrough 1.3.6.1.4.1.8239.2.1.3.2.0.8
An anomalous health condition was detected. It would have subsequently triggered hardware pass through mode followed by a reboot.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventFanFailure 1.3.6.1.4.1.8239.2.1.3.2.0.9
A cooling fan inside the device has failed. The 'pnCommonEventDescr' object has the name of the fan that failed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventFanSpeedVariation 1.3.6.1.4.1.8239.2.1.3.2.0.10
The speed of a cooling fan inside the device is either too low or too high. The 'pnCommonEventDescr' object has the name of the fan that has the problem.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventFanOk 1.3.6.1.4.1.8239.2.1.3.2.0.11
A cooling fan inside the device that had previously failed or whose speed variation was high is now working properly. The 'pnCommonEventDescr' object has the name of the fan that has recovered.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventInterfaceSpeedMismatch 1.3.6.1.4.1.8239.2.1.3.2.0.12
A mismatch is detected between the local and remote interface settings. This can happen due to a mismatch in the local and remote interface speed or mode.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventInterfaceSpeedOk 1.3.6.1.4.1.8239.2.1.3.2.0.13
A mismatch previously detected between the local and remote interface settings is now resolved. The local and remote interface speed and mode are matched.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventInterfaceDuplexMismatch 1.3.6.1.4.1.8239.2.1.3.2.0.14
A possible mismatch was detected between the duplex setting of either the local or remote interface and that of the device attached to that interface. The interface (local or remote) is identified by the 'pnCommonEventDescr' object. Note that this notification is quite different from pnCommonEventInterfaceSpeedMismatch, which compares the local and remote interfaces on the same Peribit device.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventIpsecSecurityAssociationAdded 1.3.6.1.4.1.8239.2.1.3.2.0.15
An IPSec security association has been negotiated and added to security association database.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventIpsecSecurityAssociationExpired 1.3.6.1.4.1.8239.2.1.3.2.0.16
An IPSec security association has been deleted from the security association database.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

pnCommonEventIpsecSecurityAssociationDeleted 1.3.6.1.4.1.8239.2.1.3.2.0.17
An IPSec security association has been deleted from the security association database.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE