PRIVATE-SW0657840-MIB

File: PRIVATE-SW0657840-MIB.mib (50510 bytes)

Imported modules

SNMPv2-TC SNMPv2-CONF SNMPv2-SMI
RFC1213-MIB

Imported symbols

DisplayString MODULE-COMPLIANCE OBJECT-GROUP
NOTIFICATION-GROUP enterprises MODULE-IDENTITY
OBJECT-TYPE NOTIFICATION-TYPE Counter32
IpAddress ifIndex

Defined Types

SW0657840AccountEntry  
SEQUENCE    
  sw0657840AccountIndex INTEGER
  sw0657840AccountAuthorization DisplayString
  sw0657840AccountName DisplayString
  sw0657840AccountPassword DisplayString

SW0657840TrapHostEntry  
SEQUENCE    
  sw0657840TrapHostIndex INTEGER
  sw0657840TrapHostIP IpAddress
  sw0657840TrapHostPort INTEGER
  sw0657840TrapHostCommunity DisplayString

SW0657840EventEntry  
SEQUENCE    
  sw0657840EventIndex INTEGER
  sw0657840EventName DisplayString
  sw0657840EventSendEmail INTEGER
  sw0657840EventSendSMS INTEGER
  sw0657840EventSendTrap INTEGER

SW0657840EmailUserEntry  
SEQUENCE    
  sw0657840EmailUserIndex INTEGER
  sw0657840EmailUserAddress DisplayString

SW0657840SMSUserEntry  
SEQUENCE    
  sw0657840SMSUserIndex INTEGER
  sw0657840SMSUserMobilePhone DisplayString

SW0657840LogEntry  
SEQUENCE    
  sw0657840LogIndex INTEGER
  sw0657840LogEvent DisplayString

SW0657840PortStatusEntry  
SEQUENCE    
  sw0657840PortStatusIndex INTEGER
  sw0657840PortStatusMedia DisplayString
  sw0657840PortStatusLink DisplayString
  sw0657840PortStatusPortState DisplayString
  sw0657840PortStatusAutoNego DisplayString
  sw0657840PortStatusSpdDpx DisplayString
  sw0657840PortStatusFlwCtrl DisplayString
  sw0657840PortStatuDescription DisplayString

SW0657840PortConfEntry  
SEQUENCE    
  sw0657840PortConfIndex INTEGER
  sw0657840PortConfPortState INTEGER
  sw0657840PortConfSpdDpx INTEGER
  sw0657840PortConfFlwCtrl INTEGER
  sw0657840PortConfDescription DisplayString

SW0657840MaxPktLenConfEntry  
SEQUENCE    
  sw0657840MaxPktLenConfIndex INTEGER
  sw0657840MaxPktLenConfSetting INTEGER

SW0657840BandwidthConfEntry  
SEQUENCE    
  sw0657840BandwidthConfIndex INTEGER
  sw0657840BandwidthConfIngressState INTEGER
  sw0657840BandwidthConfIngressBW INTEGER
  sw0657840BandwidthConfStormState INTEGER
  sw0657840BandwidthConfStormBW INTEGER
  sw0657840BandwidthConfEgressState INTEGER
  sw0657840BandwidthConfEgressBW INTEGER

SW0657840LoopDetectedEntry  
SEQUENCE    
  sw0657840LoopDetectedfIndex INTEGER
  sw0657840LoopDetectedStateEbl INTEGER
  sw0657840LoopDetectedCurrentStatus INTEGER
  sw0657840LoopDetectedResumed INTEGER

SW0657840SFPInfoEntry  
SEQUENCE    
  sw0657840SFPInfoIndex INTEGER
  sw0657840SFPConnectorType DisplayString
  sw0657840SFPFiberType DisplayString
  sw0657840SFPWavelength DisplayString
  sw0657840SFPBaudRate DisplayString
  sw0657840SFPVendorOUI DisplayString
  sw0657840SFPVendorName DisplayString
  sw0657840SFPVendorPN DisplayString
  sw0657840SFPVendorRev DisplayString
  sw0657840SFPVendorSN DisplayString
  sw0657840SFPDateCode DisplayString
  sw0657840SFPTemperature DisplayString
  sw0657840SFPVcc DisplayString
  sw0657840SFPTxBias DisplayString
  sw0657840SFPTxPWR DisplayString
  sw0657840SFPRxPWR DisplayString

Defined Values

privatetech 1.3.6.1.4.1.5205
The MIB module is for xxx Tech.
MODULE-IDENTITY    

switch 1.3.6.1.4.1.5205.2
OBJECT IDENTIFIER    

sw0657840ProductID 1.3.6.1.4.1.5205.2.9
OBJECT IDENTIFIER    

sw0657840Produces 1.3.6.1.4.1.5205.2.9.1
OBJECT IDENTIFIER    

sw0657840System 1.3.6.1.4.1.5205.2.9.1.1
OBJECT IDENTIFIER    

sw0657840CommonSys 1.3.6.1.4.1.5205.2.9.1.1.1
OBJECT IDENTIFIER    

sw0657840Reboot 1.3.6.1.4.1.5205.2.9.1.1.1.1
Reboot the system. Get this OID always return zero. 0 - do nothing 1 - Reboot without saving start 2 - Reboot with saving start
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1 | 2  

sw0657840BiosVsersion 1.3.6.1.4.1.5205.2.9.1.1.1.2
Get the BIOS version of the system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840FirmwareVersion 1.3.6.1.4.1.5205.2.9.1.1.1.3
Get the firmware version of the system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840HardwareVersion 1.3.6.1.4.1.5205.2.9.1.1.1.4
Get the hardware version of the system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840MechanicalVersion 1.3.6.1.4.1.5205.2.9.1.1.1.5
Get the mechanical version of the system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SerialNumber 1.3.6.1.4.1.5205.2.9.1.1.1.6
Get the Serial number of the system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840HostMacAddress 1.3.6.1.4.1.5205.2.9.1.1.1.7
Get the MAC address of the system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840DevicePort 1.3.6.1.4.1.5205.2.9.1.1.1.8
Get the quantity of ports that this system owns now.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840RamSize 1.3.6.1.4.1.5205.2.9.1.1.1.9
Get the RAM size of the system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840FlashSize 1.3.6.1.4.1.5205.2.9.1.1.1.10
Get the flash size of the system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840IP 1.3.6.1.4.1.5205.2.9.1.1.2
OBJECT IDENTIFIER    

sw0657840DhcpSetting 1.3.6.1.4.1.5205.2.9.1.1.2.1
Get/Set DHCP status of the system. 0 - DHCP disable 1 - DHCP enable
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840IPAddress 1.3.6.1.4.1.5205.2.9.1.1.2.2
Get/Set the IP address of the system. You can't set this OID if DHCP status is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sw0657840NetMask 1.3.6.1.4.1.5205.2.9.1.1.2.3
Get/Set the subnet mask of the system. You can't set this OID if DHCP status is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sw0657840DefaultGateway 1.3.6.1.4.1.5205.2.9.1.1.2.4
Get/Set the default gateway of the system. You can't set this OID if DHCP status is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sw0657840DnsSetting 1.3.6.1.4.1.5205.2.9.1.1.2.5
Get/Set the source of DNS server. You can't set this OID if DHCP status is disabled. 0 - manual, the DNS server is from manual setting 1 - auto, the DNS server is assigned by DHCP server.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840DnsServer 1.3.6.1.4.1.5205.2.9.1.1.2.6
Get/Set the DNS server of the system.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sw0657840Time 1.3.6.1.4.1.5205.2.9.1.1.3
OBJECT IDENTIFIER    

sw0657840SystemCurrentTime 1.3.6.1.4.1.5205.2.9.1.1.3.1
Get the current time of the system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840ManualTimeSetting 1.3.6.1.4.1.5205.2.9.1.1.3.2
Get/Set the system time of the device. The input format is 'Year/Month/Day/Hour/Minute/Second'. ex: 2004/1/1/12/34/25 means 2004/1/1 - 12:24:25 . The value range: Year : 2000 - 2036, Mouth : 1 - 12, Day : 1 - 31, Hour : 0 - 23, Minute : 0 - 59, Sec : 0 - 59.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840NTPServer 1.3.6.1.4.1.5205.2.9.1.1.3.3
Get/Set the NTP Time Server. You can use the IP address or domain name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840NTPTimeZone 1.3.6.1.4.1.5205.2.9.1.1.3.4
Get/Set the NTP Time Zone. The value range is between -12 and 13 -12 - GMT -12:00, -11 - GMT -11:00, -10 - GMT -10:00, -9 - GMT -09:00, -8 - GMT -08:00, -7 - GMT -07:00, -6 - GMT -06:00, -5 - GMT -05:00, -4 - GMT -04:00, -3 - GMT -03:00, -2 - GMT -02:00, -1 - GMT -01:00, 0 - GMT +00:00, 1 - GMT +01:00, 2 - GMT +02:00, 3 - GMT +03:00, 4 - GMT +04:00, 5 - GMT +05:00, 6 - GMT +06:00, 7 - GMT +07:00, 8 - GMT +08:00, 9 - GMT +09:00, 10 - GMT +10:00, 11 - GMT +11:00, 12 - GMT +12:00, 13 - GMT +13:00.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER -12..13  

sw0657840NTPTimeSync 1.3.6.1.4.1.5205.2.9.1.1.3.5
Sync time from NTP Server. Get this OID always return zero. Set the Time Server and Time Zone before doing time sync. Notice that time server must be correct! The value range (0|1): 1 - sync. 0 - do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840DaylightSavingTime 1.3.6.1.4.1.5205.2.9.1.1.3.6
Get/Set the daylight saving time. The value range is between -5 and 5. (Unit: hour)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER -5..5  

sw0657840DaylightStartTime 1.3.6.1.4.1.5205.2.9.1.1.3.7
Get/Set the Start time of Daylight Saving. The input format is 'MM/DD/HH', and daylight saving start month can't equal end month. example: month/day/hour 10/01/00 month: 01~12, day: 01~31, hour: 00~23 .
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840DaylightEndTime 1.3.6.1.4.1.5205.2.9.1.1.3.8
Get/Set the End time of Daylight Saving. The input format is 'MM/DD/HH', and daylight saving start month can't equal end month. example: month/day/hour 04/01/00 month: 01~12, day: 01~31, hour: 00~23 .
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840Account 1.3.6.1.4.1.5205.2.9.1.1.4
OBJECT IDENTIFIER    

sw0657840AccountNumber 1.3.6.1.4.1.5205.2.9.1.1.4.1
Get the current account number(s) of the system.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..5  

sw0657840AccountTable 1.3.6.1.4.1.5205.2.9.1.1.4.2
This is a list of SW0657840AccountEntry. The numbers of entries are given by the value of sw0657840AccountNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SW0657840AccountEntry

sw0657840AccountEntry 1.3.6.1.4.1.5205.2.9.1.1.4.2.1
This is the Entry(s) for account information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SW0657840AccountEntry  

sw0657840AccountIndex 1.3.6.1.4.1.5205.2.9.1.1.4.2.1.1
This is the index of the account entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..5  

sw0657840AccountAuthorization 1.3.6.1.4.1.5205.2.9.1.1.4.2.1.2
This is the authorization of the account entry.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840AccountName 1.3.6.1.4.1.5205.2.9.1.1.4.2.1.3
This is the username of the account entry.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840AccountPassword 1.3.6.1.4.1.5205.2.9.1.1.4.2.1.4
This is the password of the account entry. The return value is always '********'.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840AccountAddName 1.3.6.1.4.1.5205.2.9.1.1.4.3
This is the account name for adding operation.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840AccountAddPassword 1.3.6.1.4.1.5205.2.9.1.1.4.4
This is the account password for adding operation. The return value is always '********'.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840DoAccountAdd 1.3.6.1.4.1.5205.2.9.1.1.4.5
Add account name. OID sw0657840AccountAddName and sw0657840AccountAddPassword must be filled first. Get this OID always return zero. 1 - add account. 0 - do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840AccountDel 1.3.6.1.4.1.5205.2.9.1.1.4.6
Delete account. The value is valid sw0657840AccountIndex(Can't delete administrator).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 2..5  

sw0657840Snmp 1.3.6.1.4.1.5205.2.9.1.2
OBJECT IDENTIFIER    

sw0657840GetCommunity 1.3.6.1.4.1.5205.2.9.1.2.1
Get/Set the get-community of the SNMP.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840SetCommunity 1.3.6.1.4.1.5205.2.9.1.2.2
Get/Set the set-community of the SNMP.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840TrapHostNumber 1.3.6.1.4.1.5205.2.9.1.2.3
Get the number of trap hosts.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

sw0657840TrapHostTable 1.3.6.1.4.1.5205.2.9.1.2.4
A list of trap host entry. The numbers of entries are given by the value of sw0657840TrapHostNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SW0657840TrapHostEntry

sw0657840TrapHostEntry 1.3.6.1.4.1.5205.2.9.1.2.4.1
This is the entry information for trap host.
Status: current Access: not-accessible
OBJECT-TYPE    
  SW0657840TrapHostEntry  

sw0657840TrapHostIndex 1.3.6.1.4.1.5205.2.9.1.2.4.1.1
The index of the trap host entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

sw0657840TrapHostIP 1.3.6.1.4.1.5205.2.9.1.2.4.1.2
This is the IP of the trap host.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sw0657840TrapHostPort 1.3.6.1.4.1.5205.2.9.1.2.4.1.3
This is the receiving-port number of the trap host.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

sw0657840TrapHostCommunity 1.3.6.1.4.1.5205.2.9.1.2.4.1.4
The community name for the trap PDU.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840Alarm 1.3.6.1.4.1.5205.2.9.1.3
OBJECT IDENTIFIER    

sw0657840Event 1.3.6.1.4.1.5205.2.9.1.3.1
OBJECT IDENTIFIER    

sw0657840EventNumber 1.3.6.1.4.1.5205.2.9.1.3.1.1
Get the total number of alarm events.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840EventTable 1.3.6.1.4.1.5205.2.9.1.3.1.2
This is a list of alarm event entry. The numbers of entries are given by the value of sw0657840EventNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SW0657840EventEntry

sw0657840EventEntry 1.3.6.1.4.1.5205.2.9.1.3.1.2.1
This is the entry information for alarm event.
Status: current Access: not-accessible
OBJECT-TYPE    
  SW0657840EventEntry  

sw0657840EventIndex 1.3.6.1.4.1.5205.2.9.1.3.1.2.1.1
This is the index of the alarm event entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840EventName 1.3.6.1.4.1.5205.2.9.1.3.1.2.1.2
This is the alarm event name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840EventSendEmail 1.3.6.1.4.1.5205.2.9.1.3.1.2.1.3
Send email when alarm event is triggered.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840EventSendSMS 1.3.6.1.4.1.5205.2.9.1.3.1.2.1.4
Send SMS when alarm event is triggered.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840EventSendTrap 1.3.6.1.4.1.5205.2.9.1.3.1.2.1.5
Send trap when alarm event is triggered.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840Email 1.3.6.1.4.1.5205.2.9.1.3.2
OBJECT IDENTIFIER    

sw0657840EmailServer 1.3.6.1.4.1.5205.2.9.1.3.2.1
This is the SMTP server for alarm event.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840EmailUsername 1.3.6.1.4.1.5205.2.9.1.3.2.2
This is the Username of SMTP server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840EmailPassword 1.3.6.1.4.1.5205.2.9.1.3.2.3
This is the User Password of SMTP server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840EmailUserNumber 1.3.6.1.4.1.5205.2.9.1.3.2.4
The number of the email users that you want to send the alarm notification.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

sw0657840EmailUserTable 1.3.6.1.4.1.5205.2.9.1.3.2.5
This is a list of email user entry. The numbers of entries are given by the value of sw0657840EmailUserNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SW0657840EmailUserEntry

sw0657840EmailUserEntry 1.3.6.1.4.1.5205.2.9.1.3.2.5.1
This is the Entry information for email user entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SW0657840EmailUserEntry  

sw0657840EmailUserIndex 1.3.6.1.4.1.5205.2.9.1.3.2.5.1.1
This is the index of the email user entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

sw0657840EmailUserAddress 1.3.6.1.4.1.5205.2.9.1.3.2.5.1.2
This is the email address of the email user entry.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840SMS 1.3.6.1.4.1.5205.2.9.1.3.3
OBJECT IDENTIFIER    

sw0657840SMSServer 1.3.6.1.4.1.5205.2.9.1.3.3.1
This is the SMS server for alarm event.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840SMSUsername 1.3.6.1.4.1.5205.2.9.1.3.3.2
This is the Username of SMS server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840SMSPassword 1.3.6.1.4.1.5205.2.9.1.3.3.3
This is the Password of SMS server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840SMSUserNumber 1.3.6.1.4.1.5205.2.9.1.3.3.4
The number of the SMS users that you want to send the alarm notification.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

sw0657840SMSUserTable 1.3.6.1.4.1.5205.2.9.1.3.3.5
This is a list of SMS user entry. The numbers of entries are given by the value of sw0657840SMSUserNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SW0657840SMSUserEntry

sw0657840SMSUserEntry 1.3.6.1.4.1.5205.2.9.1.3.3.5.1
This is the Entry information for SMS user entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SW0657840SMSUserEntry  

sw0657840SMSUserIndex 1.3.6.1.4.1.5205.2.9.1.3.3.5.1.1
This is the index of the SMS user entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..6  

sw0657840SMSUserMobilePhone 1.3.6.1.4.1.5205.2.9.1.3.3.5.1.2
The SMS phone number of the SMS user entry.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840Tftp 1.3.6.1.4.1.5205.2.9.1.4
OBJECT IDENTIFIER    

sw0657840TftpServer 1.3.6.1.4.1.5205.2.9.1.4.1
Get/Set the tftp server.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

sw0657840Configuration 1.3.6.1.4.1.5205.2.9.1.5
OBJECT IDENTIFIER    

sw0657840SaveRestore 1.3.6.1.4.1.5205.2.9.1.5.1
OBJECT IDENTIFIER    

sw0657840SaveStart 1.3.6.1.4.1.5205.2.9.1.5.1.1
Save current configuration into flash memory (Save as Start Configuration). Get this OID always return zero. 1 - save. 0 - do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840SaveUser 1.3.6.1.4.1.5205.2.9.1.5.1.2
Save current configuration into flash memory (Save as User Configuration). Get this OID always return zero. 1 - save. 0 - do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840RestoreDefault 1.3.6.1.4.1.5205.2.9.1.5.1.3
Restore factory default configuration. Get this OID always return zero. 2 - restore default included default ip address. 1 - restore default without changing current ip address. 0 - do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1 | 2  

sw0657840RestoreUser 1.3.6.1.4.1.5205.2.9.1.5.1.4
Restore user configuration. Get this OID always return zero. 1 - restore. 0 - do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840ConfigFile 1.3.6.1.4.1.5205.2.9.1.5.2
OBJECT IDENTIFIER    

sw0657840ExportConfigName 1.3.6.1.4.1.5205.2.9.1.5.2.1
Get/Set the export file path and name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840DoExportConfig 1.3.6.1.4.1.5205.2.9.1.5.2.2
Do export-config. Get this OID always return zero. 1 - export start section. 2 - export user-conf section.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1 | 2  

sw0657840ImportConfigName 1.3.6.1.4.1.5205.2.9.1.5.2.3
Get/Set the import file path and name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840DoImportConfig 1.3.6.1.4.1.5205.2.9.1.5.2.4
Do import-config. Get this OID always return zero. 1 - import start section. 2 - import user-conf section.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1 | 2  

sw0657840Diagnostic 1.3.6.1.4.1.5205.2.9.1.6
OBJECT IDENTIFIER    

sw0657840EEPROMTest 1.3.6.1.4.1.5205.2.9.1.6.1
EEPROM access test.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840UartTest 1.3.6.1.4.1.5205.2.9.1.6.2
UART access test.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840DramTest 1.3.6.1.4.1.5205.2.9.1.6.3
DRAM access test.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840FlashTest 1.3.6.1.4.1.5205.2.9.1.6.4
Flash memory access test.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840InternalLoopbackTest 1.3.6.1.4.1.5205.2.9.1.6.5
Internal loopback test.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840ExternalLoopbackTest 1.3.6.1.4.1.5205.2.9.1.6.6
External loopback test.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840PingTest 1.3.6.1.4.1.5205.2.9.1.6.7
Set the host address that you want to ping and the system will return the test result.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840Log 1.3.6.1.4.1.5205.2.9.1.7
OBJECT IDENTIFIER    

sw0657840ClearLog 1.3.6.1.4.1.5205.2.9.1.7.1
Clear system log. Get this OID always return zero. 1 - clear log. 0 - do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840UploadLog 1.3.6.1.4.1.5205.2.9.1.7.2
Upload current system log. Set the correct tftp server first. The format of log file is 'ModelName_SerialNumbuer_YYMMDD_HHMM'. Get this OID always return zero. 1 - upload log 0 - do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840AutoUploadLogState 1.3.6.1.4.1.5205.2.9.1.7.3
Enable auto-upload log function. Set the correct tftp server first. The format of log file is 'ModelName_SerialNumbuer_YYMMDD_HHMM'. Get this OID always return zero. 1 - Enable auto-upload 0 - do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840LogNumber 1.3.6.1.4.1.5205.2.9.1.7.4
Get the number of current system log.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..120  

sw0657840LogTable 1.3.6.1.4.1.5205.2.9.1.7.5
This is a list of log entry. The numbers of entries are given by the value of sw0657840LogNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SW0657840LogEntry

sw0657840LogEntry 1.3.6.1.4.1.5205.2.9.1.7.5.1
This is the Entry information for system log.
Status: current Access: not-accessible
OBJECT-TYPE    
  SW0657840LogEntry  

sw0657840LogIndex 1.3.6.1.4.1.5205.2.9.1.7.5.1.1
This is the index of the log entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..120  

sw0657840LogEvent 1.3.6.1.4.1.5205.2.9.1.7.5.1.2
This is the detail information of the log entry.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840Firmware 1.3.6.1.4.1.5205.2.9.1.8
OBJECT IDENTIFIER    

sw0657840FirmwareFileName 1.3.6.1.4.1.5205.2.9.1.8.1
Get/Set the path and filename for firmware upgrading.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840DoFirmwareUpgrade 1.3.6.1.4.1.5205.2.9.1.8.2
Do firmware upgrade. Get this OID always return zero. 1 - do firmware upgrade. 0 - do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840Port 1.3.6.1.4.1.5205.2.9.1.9
OBJECT IDENTIFIER    

sw0657840PortStatus 1.3.6.1.4.1.5205.2.9.1.9.1
OBJECT IDENTIFIER    

sw0657840PortStatusNumber 1.3.6.1.4.1.5205.2.9.1.9.1.1
Get the number of port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840PortStatusTable 1.3.6.1.4.1.5205.2.9.1.9.1.2
This is a list of port status entry. The numbers of entries are given by the value of sw0657840PortStatusNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SW0657840PortStatusEntry

sw0657840PortStatusEntry 1.3.6.1.4.1.5205.2.9.1.9.1.2.1
This is the entry(s) for port status information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SW0657840PortStatusEntry  

sw0657840PortStatusIndex 1.3.6.1.4.1.5205.2.9.1.9.1.2.1.1
This is the index of the port status entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840PortStatusMedia 1.3.6.1.4.1.5205.2.9.1.9.1.2.1.2
The port media type of the port status entry.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  


sw0657840PortStatusPortState 1.3.6.1.4.1.5205.2.9.1.9.1.2.1.4
This is the port state of the port status entry.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840PortStatusAutoNego 1.3.6.1.4.1.5205.2.9.1.9.1.2.1.5
This is the auto negotiation of the port status entry.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840PortStatusSpdDpx 1.3.6.1.4.1.5205.2.9.1.9.1.2.1.6
This is the speed/duplex of the port status entry.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840PortStatusFlwCtrl 1.3.6.1.4.1.5205.2.9.1.9.1.2.1.7
This is the flow control of the port status entry.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840PortStatuDescription 1.3.6.1.4.1.5205.2.9.1.9.1.2.1.8
This is the description of port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840PortConf 1.3.6.1.4.1.5205.2.9.1.9.2
OBJECT IDENTIFIER    

sw0657840PortConfNumber 1.3.6.1.4.1.5205.2.9.1.9.2.1
Get the number of port configuration.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840PortConfTable 1.3.6.1.4.1.5205.2.9.1.9.2.2
This is a list of port configuration entry. The numbers of entries are given by the value of sw0657840PortConfNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SW0657840PortConfEntry

sw0657840PortConfEntry 1.3.6.1.4.1.5205.2.9.1.9.2.2.1
This is the Entry(s) for port configuration information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SW0657840PortConfEntry  

sw0657840PortConfIndex 1.3.6.1.4.1.5205.2.9.1.9.2.2.1.1
This is the index of the port configuration entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840PortConfPortState 1.3.6.1.4.1.5205.2.9.1.9.2.2.1.2
This is the port state of the port configuration entry. 0 - disabled. 1 - enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840PortConfSpdDpx 1.3.6.1.4.1.5205.2.9.1.9.2.2.1.3
This is the speed/duplex of the port configuration entry. 0 - auto. 1 - 10M/Half. 2 - 10M/Full. 3 - 100M/Half. 4 - 100M/Full. 5 - 1G/Full.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..5  

sw0657840PortConfFlwCtrl 1.3.6.1.4.1.5205.2.9.1.9.2.2.1.4
This is the flow control of the port configuration entry. 0 - disabled. 1 - enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840PortConfDescription 1.3.6.1.4.1.5205.2.9.1.9.2.2.1.5
This is the description of port.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840Mirror 1.3.6.1.4.1.5205.2.9.1.10
OBJECT IDENTIFIER    

sw0657840MirrorMode 1.3.6.1.4.1.5205.2.9.1.10.1
Get/Set the Mirror mode. 0 - disabled. 1 - rx enable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840MirroringPort 1.3.6.1.4.1.5205.2.9.1.10.2
Get/Set the mirroring port. The port range is from 1 to 24.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840MirroredPorts 1.3.6.1.4.1.5205.2.9.1.10.3
Get/Set the monitored ports. The port range is from 1 to 24, and the syntax is 1,5-7.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

sw0657840MaxPktLen 1.3.6.1.4.1.5205.2.9.1.11
OBJECT IDENTIFIER    

sw0657840MaxPktLen1 1.3.6.1.4.1.5205.2.9.1.11.1
OBJECT IDENTIFIER    

sw0657840MaxPktLenPortNumber 1.3.6.1.4.1.5205.2.9.1.11.1.1
Get the number of Max. packet length.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840MaxPktLenConfTable 1.3.6.1.4.1.5205.2.9.1.11.1.2
This is a list of Max. packet length entry. The numbers of entries are given by the value of sw0657840MaxPktLenPortNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SW0657840MaxPktLenConfEntry

sw0657840MaxPktLenConfEntry 1.3.6.1.4.1.5205.2.9.1.11.1.2.1
Entry(s) for Max. packet length information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SW0657840MaxPktLenConfEntry  

sw0657840MaxPktLenConfIndex 1.3.6.1.4.1.5205.2.9.1.11.1.2.1.1
This is the index of the Max. packet length entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840MaxPktLenConfSetting 1.3.6.1.4.1.5205.2.9.1.11.1.2.1.2
Get/Set the Max. packet length. The Max. packet length is 1518,1532,or 9216.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1518 | 1532 | 9216  

sw0657840Bandwidth 1.3.6.1.4.1.5205.2.9.1.12
OBJECT IDENTIFIER    

sw0657840Bandwidth1 1.3.6.1.4.1.5205.2.9.1.12.1
OBJECT IDENTIFIER    

sw0657840BandwidthPortNumber 1.3.6.1.4.1.5205.2.9.1.12.1.1
Get the number of bandwidth management configuration.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840BandwidthConfTable 1.3.6.1.4.1.5205.2.9.1.12.1.2
This is a list of bandwidth management configuration entry. The numbers of entries are given by the value of sw0657840BandwidthPortNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SW0657840BandwidthConfEntry

sw0657840BandwidthConfEntry 1.3.6.1.4.1.5205.2.9.1.12.1.2.1
This is the Entry(s) for bandwidth management configuration information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SW0657840BandwidthConfEntry  

sw0657840BandwidthConfIndex 1.3.6.1.4.1.5205.2.9.1.12.1.2.1.1
This is the index of the bandwidth management configuration entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840BandwidthConfIngressState 1.3.6.1.4.1.5205.2.9.1.12.1.2.1.2
The ingress state of the bandwidth management configures entry. 0 - disabled. 1 - enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840BandwidthConfIngressBW 1.3.6.1.4.1.5205.2.9.1.12.1.2.1.3
Get/Set the ingress rate of the bandwidth management configuration. The ingress rate is from 0 to 1000.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1000  

sw0657840BandwidthConfStormState 1.3.6.1.4.1.5205.2.9.1.12.1.2.1.4
The storm state of the bandwidth management configuration entry. 0 - disabled. 1 - enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840BandwidthConfStormBW 1.3.6.1.4.1.5205.2.9.1.12.1.2.1.5
Get/Set the storm rate of the bandwidth management configuration. The storm rate is from 0 to 1000.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1000  

sw0657840BandwidthConfEgressState 1.3.6.1.4.1.5205.2.9.1.12.1.2.1.6
The egress state of the bandwidth management configuration entry. 0 - disabled. 1 - enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840BandwidthConfEgressBW 1.3.6.1.4.1.5205.2.9.1.12.1.2.1.7
Get/Set the egress rate of the bandwidth management configuration. The egress rate is from 0 to 1000.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..1000  

sw0657840LoopDetectedConf 1.3.6.1.4.1.5205.2.9.1.13
OBJECT IDENTIFIER    

sw0657840LoopDetectedNumber 1.3.6.1.4.1.5205.2.9.1.13.1
Get the number of loop detected entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840LoopDetectedTable 1.3.6.1.4.1.5205.2.9.1.13.2
A list of loop detected entry. The numbers of entries are given by the value of sw0657840LoopDetectedNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SW0657840LoopDetectedEntry

sw0657840LoopDetectedEntry 1.3.6.1.4.1.5205.2.9.1.13.2.1
Entry(s) for loop detected information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SW0657840LoopDetectedEntry  

sw0657840LoopDetectedfIndex 1.3.6.1.4.1.5205.2.9.1.13.2.1.1
The index of the loop detected entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840LoopDetectedStateEbl 1.3.6.1.4.1.5205.2.9.1.13.2.1.2
The state of the loop detected entry. 0 - disabled. 1 - enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840LoopDetectedCurrentStatus 1.3.6.1.4.1.5205.2.9.1.13.2.1.3
The current status of the loop detected port. 0 - unlocked 1 - locked due to the loop condition
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840LoopDetectedResumed 1.3.6.1.4.1.5205.2.9.1.13.2.1.4
Unlock the port which is locked due to loop condition. Get this OID always return zero. 1 - unlock the port, 0 - do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840LoopDetectedAction 1.3.6.1.4.1.5205.2.9.1.13.3
Set the corresponding action while loop is detected. 1 - lock the loop port, 0 - do nothing.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 1  

sw0657840SFPInfo 1.3.6.1.4.1.5205.2.9.1.14
OBJECT IDENTIFIER    

sw0657840SFPInfoNumber 1.3.6.1.4.1.5205.2.9.1.14.1
Get the number of sfp info entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840SFPInfoTable 1.3.6.1.4.1.5205.2.9.1.14.2
A list of sfp info entry. The numbers of entries are given by the value of sw0657840SFPInfoNumber.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SW0657840SFPInfoEntry

sw0657840SFPInfoEntry 1.3.6.1.4.1.5205.2.9.1.14.2.1
Entry(s) for SFP information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SW0657840SFPInfoEntry  

sw0657840SFPInfoIndex 1.3.6.1.4.1.5205.2.9.1.14.2.1.1
The index of the sfp info entry.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sw0657840SFPConnectorType 1.3.6.1.4.1.5205.2.9.1.14.2.1.2
Get connector type of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPFiberType 1.3.6.1.4.1.5205.2.9.1.14.2.1.3
Get fiber type of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPWavelength 1.3.6.1.4.1.5205.2.9.1.14.2.1.4
Get tx central wavelength of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPBaudRate 1.3.6.1.4.1.5205.2.9.1.14.2.1.5
Get baud rate of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPVendorOUI 1.3.6.1.4.1.5205.2.9.1.14.2.1.6
Get vendor OUI of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPVendorName 1.3.6.1.4.1.5205.2.9.1.14.2.1.7
Get vendor name of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPVendorPN 1.3.6.1.4.1.5205.2.9.1.14.2.1.8
Get vendor part number of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPVendorRev 1.3.6.1.4.1.5205.2.9.1.14.2.1.9
Get vendor revision number of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPVendorSN 1.3.6.1.4.1.5205.2.9.1.14.2.1.10
Get vendor serial number of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPDateCode 1.3.6.1.4.1.5205.2.9.1.14.2.1.11
Get data code of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPTemperature 1.3.6.1.4.1.5205.2.9.1.14.2.1.12
Get current temperature of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPVcc 1.3.6.1.4.1.5205.2.9.1.14.2.1.13
Get current internal supply voltage of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPTxBias 1.3.6.1.4.1.5205.2.9.1.14.2.1.14
Get current TX Bias of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPTxPWR 1.3.6.1.4.1.5205.2.9.1.14.2.1.15
Get current TX output power of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840SFPRxPWR 1.3.6.1.4.1.5205.2.9.1.14.2.1.16
Get current Received Power of the sfp.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sw0657840TrapEntry 1.3.6.1.4.1.5205.2.9.1.20
OBJECT IDENTIFIER    

sw0657840ModuleInserted 1.3.6.1.4.1.5205.2.9.1.20.1
Send the trap when a module is inserted to the system. The OID value means the port number.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840ModuleRemoved 1.3.6.1.4.1.5205.2.9.1.20.2
Send the trap when a module is removed from the system. The OID value means the port number.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840DualMediaSwapped 1.3.6.1.4.1.5205.2.9.1.20.3
Send the trap when the dual media port changed. The OID value means the port number.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840LoopDetected 1.3.6.1.4.1.5205.2.9.1.20.5
Send the trap when loop condition has been detected. The OID value means the port number.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840StpStateDisabled 1.3.6.1.4.1.5205.2.9.1.20.100
Send the trap when the operational state of STP is from enabled to disabled.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840StpStateEnabled 1.3.6.1.4.1.5205.2.9.1.20.101
Send the trap when the operational state of STP is from disabled to enabled.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840StpTopologyChanged 1.3.6.1.4.1.5205.2.9.1.20.102
Send the trap when RSTP determines a port should enter the FORWARDING state (a topology change occurs). The OID value is the ifIndex of the port that produces the topology change.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840LacpStateDisabled 1.3.6.1.4.1.5205.2.9.1.20.120
Send the trap when the operational state of LACP is from enabled to disabled. The OID value means the disabled Group ID.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840LacpStateEnabled 1.3.6.1.4.1.5205.2.9.1.20.121
Send the trap when the operational state of LACP is from disabled to enabled. The OID value means the disabled Group ID.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840LacpPortAdded 1.3.6.1.4.1.5205.2.9.1.20.123
Send the trap when the state of port is in 'trunk ready'.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840LacpPortTrunkFailure 1.3.6.1.4.1.5205.2.9.1.20.124
Send the trap when one port is not able to be aggregated due to duplex-mode of the port.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840GvrpStateDisabled 1.3.6.1.4.1.5205.2.9.1.20.140
Send the trap when the operational state of GVRP is from enabled to disabled.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840GvrpStateEnabled 1.3.6.1.4.1.5205.2.9.1.20.141
Send the trap when the operational state of LACP is from disabled to enabled.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840VlanStateDisabled 1.3.6.1.4.1.5205.2.9.1.20.150
Send the trap when the operational state of vlan is from enabled to disabled. The OID value means the enabled Group ID.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840VlanPortBaseEnabled 1.3.6.1.4.1.5205.2.9.1.20.151
Send the trap when the operational state of vlan is changed to port-based vlan.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840VlanTagBaseEnabled 1.3.6.1.4.1.5205.2.9.1.20.152
Send the trap when the operational state of vlan is changed to tag-based vlan.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840VlanMetroModeEnabled 1.3.6.1.4.1.5205.2.9.1.20.153
Send the trap when the operational state of vlan is changed to Metro-mode vlan. The OID value means the uplink port with this metro-mode vlan.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840VlanDoubleTagEnabled 1.3.6.1.4.1.5205.2.9.1.20.154
Send the trap when the operational state of vlan is changed to Double-tag vlan.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840UserLogin 1.3.6.1.4.1.5205.2.9.1.20.200
Send the trap when one user logins the system.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840UserLogout 1.3.6.1.4.1.5205.2.9.1.20.201
Send the trap when one user logouts the system.
Status: current Access: read-only
NOTIFICATION-TYPE    

sw0657840TrapVariable 1.3.6.1.4.1.5205.2.9.1.21
OBJECT IDENTIFIER    

username 1.3.6.1.4.1.5205.2.9.1.21.1
System account name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

groupId 1.3.6.1.4.1.5205.2.9.1.21.2
The Trunk group ID of LACP.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

actorkey 1.3.6.1.4.1.5205.2.9.1.21.3
This is the actor key information for LACP.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

partnerkey 1.3.6.1.4.1.5205.2.9.1.21.4
This is the partner key information for LACP.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647