PRVT-CONFIGCHANGE-MIB

File: PRVT-CONFIGCHANGE-MIB.mib (5498 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC PRVT-SWITCH-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
RowPointer DisplayString switch

Defined Values

prvtConfigChangeMIB 1.3.6.1.4.1.738.1.5.150
Initial version. This MIB will provied traps for change
MODULE-IDENTITY    

prvtConfigChangeAlarmOID 1.3.6.1.4.1.738.1.5.150.1.1
The configChangeAlarmOID specifies the OID of an object whose value has been changed.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OBJECT IDENTIFIER  

prvtConfigChangeAlarmRow 1.3.6.1.4.1.738.1.5.150.1.2
The configChangeAlarmRow specifies the OID of the row from table, whose entry has been changed.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  RowPointer  

cliConfigChangeNodePrompt 1.3.6.1.4.1.738.1.5.150.1.3
Shows the CLI prompt.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

cliConfigChangeCommand 1.3.6.1.4.1.738.1.5.150.1.4
Shows executed command.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

snmpServerStatus 1.3.6.1.4.1.738.1.5.150.1.5
Shows the enabled/disabled status of the SNMP server.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

prvtConfigChangeAlarm 1.3.6.1.4.1.738.1.5.150.0.1
This notification is generated when the value of configurable attribute has been changed. The notification can be used to trigger maintenance polling of the running configuration on the device. One of the varbinds will point either to entry of the modified table (configChangeAlarmRow) or the OID of the modified scalar object
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

cliConfigurationChange 1.3.6.1.4.1.738.1.5.150.0.2
This notification is generated when command in configuration node is executed.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

snmpServerStatusChange 1.3.6.1.4.1.738.1.5.150.0.3
The notification shall be sent whenever the enabled/disabled status of the SNMP server changes. If the status is changed from enabled to disabled, the notification shall be sent prior to disabling the SNMP server.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

prvtConfigChangeNotifications 1.3.6.1.4.1.738.1.5.150.0
OBJECT IDENTIFIER    

prvtConfigChangeObjects 1.3.6.1.4.1.738.1.5.150.1
OBJECT IDENTIFIER    

prvtConfigChangeConformance 1.3.6.1.4.1.738.1.5.150.3
OBJECT IDENTIFIER