PRVT-NETWORK-LOOPBACK-TEST-MIB

File: PRVT-NETWORK-LOOPBACK-TEST-MIB.mib (7430 bytes)

Imported modules

SNMPv2-SMI IF-MIB SNMPv2-CONF
SNMPv2-TC PRVT-SWITCH-ACCESS-LIST-MIB PRVT-SWITCH-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE ifIndex
MODULE-COMPLIANCE OBJECT-GROUP NOTIFICATION-GROUP
TimeStamp RowStatus NOTIFICATION-TYPE
accessListControlListGroup ipSwitch

Defined Types

PrvtNetworkLoopbackTestEntry  
SEQUENCE    
  prvtNetworkLoopTestDuration INTEGER
  prvtNetworkLoopStartDuration TimeStamp
  prvtNetworkLoopEndDuration TimeStamp
  prvtNetworkLoopRowStatus RowStatus

Defined Values

prvtNetworkLoopbackTestMib 1.3.6.1.4.1.738.1.6.7
This MIB contains managed objects definitions for encapsulating Loopback Tester feature that enables or disables embedded mechanisms for network troubleshooting, diagnostics and measurement.
MODULE-IDENTITY    

prvtNetworkLoopbackTestNotifications 1.3.6.1.4.1.738.1.6.7.0
OBJECT IDENTIFIER    

prvtNetworkLoopbackTestObjects 1.3.6.1.4.1.738.1.6.7.1
OBJECT IDENTIFIER    

prvtNetworkLoopbackTestConformance 1.3.6.1.4.1.738.1.6.7.2
OBJECT IDENTIFIER    

prvtNetworkLoopbackTestTable 1.3.6.1.4.1.738.1.6.7.1.1
This table contains object for configuring and display information about Network Loopback Tester.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrvtNetworkLoopbackTestEntry

prvtNetworkLoopbackTestEntry 1.3.6.1.4.1.738.1.6.7.1.1.1
An entry in the prvtNetworkLoopbackTestTable table
Status: current Access: not-accessible
OBJECT-TYPE    
  PrvtNetworkLoopbackTestEntry  

prvtNetworkLoopTestDuration 1.3.6.1.4.1.738.1.6.7.1.1.1.1
An integer that identifies the duration in seconds of Loopback test. For infinite Loopback tests object will have the value 0.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..100000  

prvtNetworkLoopStartDuration 1.3.6.1.4.1.738.1.6.7.1.1.1.2
Star time of Loopback test. For infinite Loopback tests object will have the value 0.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

prvtNetworkLoopEndDuration 1.3.6.1.4.1.738.1.6.7.1.1.1.3
End time of Loopback test. For infinite Loopback tests object will have the value 0.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

prvtNetworkLoopRowStatus 1.3.6.1.4.1.738.1.6.7.1.1.1.4
Network Loopback Test RowStatus. Both createAndGo(4) and createAndWait(5) are available. CreateAndGo(4) is used for enable a Loopback test unlimited in time and CreateAndWait(4) for enable a Loopback Test on a period specified by prvtNetworkLoopTestDuration.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

prvtNetworkLoopbackTestFinish 1.3.6.1.4.1.738.1.6.7.0.1
This notification is sent when a Network Loopback Test is complete.
Status: current Access: read-create
NOTIFICATION-TYPE    

prvtNetworkLoopTestCompliances 1.3.6.1.4.1.738.1.6.7.2.1
OBJECT IDENTIFIER    

prvtNetworkLoopTestGroups 1.3.6.1.4.1.738.1.6.7.2.2
OBJECT IDENTIFIER    

prvtNetworkLoopTestCompliance 1.3.6.1.4.1.738.1.6.7.2.1.1
The compliance statement for Network Loopback Tester.
Status: current Access: read-create
MODULE-COMPLIANCE    

prvtNetworkLoopTestGroup 1.3.6.1.4.1.738.1.6.7.2.2.1
The group of objects regarding Network Looback Tester feature.
Status: current Access: read-create
OBJECT-GROUP    

prvtNetworkLoopTestNotificationsGroup 1.3.6.1.4.1.738.1.6.7.2.2.2
The collection of Notifications used to indicate general status information of Network Looback Tester feature.
Status: current Access: read-create
NOTIFICATION-GROUP