PRVT-NETWORK-LOOPBACK-TEST-MIB
File:
PRVT-NETWORK-LOOPBACK-TEST-MIB.mib (7430 bytes)
Imported modules
Imported symbols
Defined Types
PrvtNetworkLoopbackTestEntry |
|
SEQUENCE |
|
|
|
|
prvtNetworkLoopTestDuration |
INTEGER |
|
|
prvtNetworkLoopStartDuration |
TimeStamp |
|
|
prvtNetworkLoopEndDuration |
TimeStamp |
|
|
prvtNetworkLoopRowStatus |
RowStatus |
|
Defined Values
prvtNetworkLoopbackTestMib |
1.3.6.1.4.1.738.1.6.7 |
This MIB contains managed objects definitions for
encapsulating Loopback Tester feature that enables or disables
embedded mechanisms for network troubleshooting, diagnostics and measurement. |
MODULE-IDENTITY |
|
|
|
prvtNetworkLoopbackTestEntry |
1.3.6.1.4.1.738.1.6.7.1.1.1 |
An entry in the prvtNetworkLoopbackTestTable table |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PrvtNetworkLoopbackTestEntry |
|
|
prvtNetworkLoopTestDuration |
1.3.6.1.4.1.738.1.6.7.1.1.1.1 |
An integer that identifies the duration in seconds of Loopback test.
For infinite Loopback tests object will have the value 0. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..100000 |
|
prvtNetworkLoopStartDuration |
1.3.6.1.4.1.738.1.6.7.1.1.1.2 |
Star time of Loopback test.
For infinite Loopback tests object will have the value 0. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeStamp |
|
|
prvtNetworkLoopEndDuration |
1.3.6.1.4.1.738.1.6.7.1.1.1.3 |
End time of Loopback test.
For infinite Loopback tests object will have the value 0. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeStamp |
|
|
prvtNetworkLoopRowStatus |
1.3.6.1.4.1.738.1.6.7.1.1.1.4 |
Network Loopback Test RowStatus.
Both createAndGo(4) and createAndWait(5) are available.
CreateAndGo(4) is used for enable a Loopback test unlimited in time and CreateAndWait(4)
for enable a Loopback Test on a period specified by prvtNetworkLoopTestDuration. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
prvtNetworkLoopbackTestFinish |
1.3.6.1.4.1.738.1.6.7.0.1 |
This notification is sent when a Network Loopback Test is complete. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
prvtNetworkLoopTestCompliance |
1.3.6.1.4.1.738.1.6.7.2.1.1 |
The compliance statement for Network Loopback Tester. |
Status: current |
Access: read-create |
MODULE-COMPLIANCE |
|
|
|
prvtNetworkLoopTestGroup |
1.3.6.1.4.1.738.1.6.7.2.2.1 |
The group of objects regarding Network Looback Tester feature. |
Status: current |
Access: read-create |
OBJECT-GROUP |
|
|
|
prvtNetworkLoopTestNotificationsGroup |
1.3.6.1.4.1.738.1.6.7.2.2.2 |
The collection of Notifications used to indicate general status information
of Network Looback Tester feature. |
Status: current |
Access: read-create |
NOTIFICATION-GROUP |
|
|
|