PRVT-REDUNDANCY-MIB

File: PRVT-REDUNDANCY-MIB.mib (5396 bytes)

Imported modules

PRVT-SYS-INFO-MIB SNMPv2-SMI

Imported symbols

software MODULE-IDENTITY NOTIFICATION-TYPE
OBJECT-TYPE Unsigned32

Defined Types

PrvtRedundancyChassisEntry  
SEQUENCE    
  prvtRedundancyChassisSlotId Unsigned32
  prvtRedundancyChassisLICType INTEGER
  prvtRedundancyChassisStatus INTEGER
  prvtRedundancyChassisEntryStatus INTEGER

Defined Values

prvtRedundancyMIB 1.3.6.1.4.1.738.1.111.5
Monitoring of components redundancy protection
MODULE-IDENTITY    

prvtRedundancyNotifications 1.3.6.1.4.1.738.1.111.5.0
OBJECT IDENTIFIER    

prvtRedundancyObjects 1.3.6.1.4.1.738.1.111.5.1
OBJECT IDENTIFIER    

prvtRedundancyChassisTable 1.3.6.1.4.1.738.1.111.5.1.1
A list of slots in the chassis
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PrvtRedundancyChassisEntry

prvtRedundancyChassisEntry 1.3.6.1.4.1.738.1.111.5.1.1.1
Entry in prvtRedundancyChassisTable
Status: current Access: not-accessible
OBJECT-TYPE    
  PrvtRedundancyChassisEntry  

prvtRedundancyChassisSlotId 1.3.6.1.4.1.738.1.111.5.1.1.1.1
Index in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

prvtRedundancyChassisLICType 1.3.6.1.4.1.738.1.111.5.1.1.1.2
LIC type
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER lc-unknown(1), lc-8020-10GE(3), lc-8064-1GE(4), lc-8032-1GE(19), lc-8062-1GE(20)  

prvtRedundancyChassisStatus 1.3.6.1.4.1.738.1.111.5.1.1.1.3
Chassis status
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER protected(0), notProtected(1)  

prvtRedundancyChassisEntryStatus 1.3.6.1.4.1.738.1.111.5.1.1.1.4
Chassis Entry status
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER extracted(0), inserted(1)  

licStatus 1.3.6.1.4.1.738.1.111.5.0.1
LIC prvtRedundancyChassisEntryStatus has been changed. Card slotId is present as a key.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

switchover 1.3.6.1.4.1.738.1.111.5.0.2
Switchover has happend - link between Active and Standby HUB is broken.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

redundancyStatus 1.3.6.1.4.1.738.1.111.5.0.3
Chassis redundancy-status
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE