PRVT-SYNC-ETHERNET-MIB

File: PRVT-SYNC-ETHERNET-MIB.mib (22037 bytes)

Imported modules

IF-MIB PRVT-SWITCH-MIB SNMPv2-SMI
SNMPv2-TC

Imported symbols

ifIndex switch Integer32
MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
Unsigned32 DateAndTime RowStatus
TEXTUAL-CONVENTION TruthValue

Defined Types

PrvtSyncEthernetQualityLevelType  
Clock Quality Levels.
TEXTUAL-CONVENTION    
  INTEGER prc(2), ssuA(4), ssuB(8), sec(11), dnu(15), stu(16), prs(17), tnc(20), st2(23), st3(26), smc(28), st3e(29), prov(30), dus(31), invalid(64), failed(65)  

SyncEthernetClockSourceEntry  
SEQUENCE    
  syncEthernetClockSourceRowStatus RowStatus
  syncEthernetClockSourceAdminStatus INTEGER
  syncEthernetClockSourceEsmc TruthValue
  syncEthernetClockSourceFrequency Unsigned32
  syncEthernetClockSourceQuality PrvtSyncEthernetQualityLevelType
  syncEthernetClockSourceQualityChangeNotify TruthValue
  syncEthernetClockSourceRecvQualityLevel PrvtSyncEthernetQualityLevelType
  syncEthernetClockSourceLastRecvEsmcPduTime DateAndTime
  syncEthernetClockSourceLastRecvEsmcErrorPduTime DateAndTime
  syncEthernetClockSourceLastRecvEsmcPduType Unsigned32
  syncEthernetClockSourceLastRecvLastError Unsigned32
  syncEthernetClockSourceNumRecvEsmcPdu Unsigned32
  syncEthernetClockSourceNumDiscEsmcPdu Unsigned32
  syncEthernetClockSourceNumSignalFail Unsigned32
  syncEthernetClockSourceQualityInvalidNotify TruthValue
  syncEthernetClockSourceEsmcInvalidNotify TruthValue

SyncEthernetClockOutputEntry  
SEQUENCE    
  syncEthernetClockOutputRowStatus RowStatus
  syncEthernetClockOutputEsmc TruthValue
  syncEthernetClockOutputFrequency Unsigned32
  syncEthernetClockOutputDpll Integer32
  syncEthernetClockOutputQualityLevel PrvtSyncEthernetQualityLevelType
  syncEthernetClockOutputLastQualityLevelChange DateAndTime
  syncEthernetClockOutputMsgEvent TruthValue
  syncEthernetClockOutputNumTransmittedEsmcPdu Unsigned32
  syncEthernetClockOutputNumTransmittedEventEsmcPdu Unsigned32

SyncEthernetDpllEntry  
SEQUENCE    
  syncEthernetDpllModuleId Integer32
  syncEthernetDpllRowStatus RowStatus
  syncEthernetDpllAdminStatus INTEGER
  syncEthernetDpllReferenceSelection INTEGER
  syncEthernetDpllEnableQualityLevel TruthValue
  syncEthernetDpllStatusChangeNotify TruthValue
  syncEthernetDpllReferenceChangeNotify TruthValue
  syncEthernetDpllStatus INTEGER
  syncEthernetDpllStatusLastChange DateAndTime
  syncEthernetDpllSystemQualityLevel PrvtSyncEthernetQualityLevelType
  syncEthernetDpllSystemQualityLevelLastChange DateAndTime
  syncEthernetDpllSelectedReferenceClock OCTET STRING
  syncEthernetDpllSelectedReferenceClockChange DateAndTime

SyncEthernetDpllClkRefEntry  
SEQUENCE    
  syncEthernetDpllClkRefRowStatus RowStatus
  syncEthernetDpllClkRefPriority Unsigned32
  syncEthernetDpllClkRefLockOut TruthValue
  syncEthernetDpllClkRefFailStatus Integer32

Defined Values

prvtSyncEthernetMIB 1.3.6.1.4.1.738.1.5.170
This is the MIB module to manage synchronization over ethernet.
MODULE-IDENTITY    

prvtSyncEthernetMIBNotifications 1.3.6.1.4.1.738.1.5.170.0
OBJECT IDENTIFIER    

prvtSyncEthernetMIBObjects 1.3.6.1.4.1.738.1.5.170.1
OBJECT IDENTIFIER    

syncEthernetHoldOffTime 1.3.6.1.4.1.738.1.5.170.1.1
Timeout value, in millisseconds, for the hold-off timer.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 300..1800  

syncEthernetWaitToRestoreTime 1.3.6.1.4.1.738.1.5.170.1.2
Timeout value, in minutes, for the wait-to-restore timer.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..12  

syncEthernetG781OptionMode 1.3.6.1.4.1.738.1.5.170.1.3
Specify which G.781 option mode to operate in.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER option1(1), option2(2)  

syncEthernetClockSourceTable 1.3.6.1.4.1.738.1.5.170.1.10
Source clock synchronization table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SyncEthernetClockSourceEntry

syncEthernetClockSourceEntry 1.3.6.1.4.1.738.1.5.170.1.10.1
Source clock synchronization entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SyncEthernetClockSourceEntry  

syncEthernetClockSourceRowStatus 1.3.6.1.4.1.738.1.5.170.1.10.1.2
Clock source synchronization table rowstatus.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

syncEthernetClockSourceAdminStatus 1.3.6.1.4.1.738.1.5.170.1.10.1.3
Enable clock source.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER up(1), down(2)  

syncEthernetClockSourceEsmc 1.3.6.1.4.1.738.1.5.170.1.10.1.4
Enable receiving ESMC messages (Synchronization Status Messages). Only applicable for BITS clock sources.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

syncEthernetClockSourceFrequency 1.3.6.1.4.1.738.1.5.170.1.10.1.5
Specify input frequency - N*8kHz Only applicable for BITS clock sources.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2431  

syncEthernetClockSourceQuality 1.3.6.1.4.1.738.1.5.170.1.10.1.6
Specify quality level In G781-option I mode, valid values are prs, ssuA, ssuB, dnu. In G781-option II mode, valid values are stu, prs, tnc, st2, st3, smc, st3e, dus, prov.
Status: current Access: read-create
OBJECT-TYPE    
  PrvtSyncEthernetQualityLevelType  

syncEthernetClockSourceQualityChangeNotify 1.3.6.1.4.1.738.1.5.170.1.10.1.7
Enable quality level change notifications
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

syncEthernetClockSourceRecvQualityLevel 1.3.6.1.4.1.738.1.5.170.1.10.1.8
The received quality level value.
Status: current Access: read-only
OBJECT-TYPE    
  PrvtSyncEthernetQualityLevelType  

syncEthernetClockSourceLastRecvEsmcPduTime 1.3.6.1.4.1.738.1.5.170.1.10.1.9
Time elapsed since the last valid ESMC message received
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

syncEthernetClockSourceLastRecvEsmcErrorPduTime 1.3.6.1.4.1.738.1.5.170.1.10.1.10
Time elapsed since the last invalid ESMC message received
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

syncEthernetClockSourceLastRecvEsmcPduType 1.3.6.1.4.1.738.1.5.170.1.10.1.11
Last received ESMC message type
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

syncEthernetClockSourceLastRecvLastError 1.3.6.1.4.1.738.1.5.170.1.10.1.12
Last error code
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

syncEthernetClockSourceNumRecvEsmcPdu 1.3.6.1.4.1.738.1.5.170.1.10.1.13
Total number of received ESMC messages
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

syncEthernetClockSourceNumDiscEsmcPdu 1.3.6.1.4.1.738.1.5.170.1.10.1.14
Total number of discarded ESMC messages
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

syncEthernetClockSourceNumSignalFail 1.3.6.1.4.1.738.1.5.170.1.10.1.15
Total number of generated signal failure events
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

syncEthernetClockSourceQualityInvalidNotify 1.3.6.1.4.1.738.1.5.170.1.10.1.16
Enable invalid quality notifications
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

syncEthernetClockSourceEsmcInvalidNotify 1.3.6.1.4.1.738.1.5.170.1.10.1.17
Enable invalid ESMC notifications
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

syncEthernetClockOutputTable 1.3.6.1.4.1.738.1.5.170.1.12
Output clock synchronization table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SyncEthernetClockOutputEntry

syncEthernetClockOutputEntry 1.3.6.1.4.1.738.1.5.170.1.12.1
Output clock synchronization entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  SyncEthernetClockOutputEntry  

syncEthernetClockOutputRowStatus 1.3.6.1.4.1.738.1.5.170.1.12.1.2
syncEthernetClockOutput table rowStatus
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

syncEthernetClockOutputEsmc 1.3.6.1.4.1.738.1.5.170.1.12.1.3
Enable sending ESMC messages Only applicable for BITS clock outputs.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

syncEthernetClockOutputFrequency 1.3.6.1.4.1.738.1.5.170.1.12.1.4
Specify output frequency - N*8kHz Only applicable for BITS clock outputs.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..2431  

syncEthernetClockOutputDpll 1.3.6.1.4.1.738.1.5.170.1.12.1.5
Assign output clock to DPLL Only applicable for BITS clock outputs. Must be set to the syncEthernetDpllModuleId value of an existing row in syncEthernetDpllTable.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..1  

syncEthernetClockOutputQualityLevel 1.3.6.1.4.1.738.1.5.170.1.12.1.6
Last quality level value sent
Status: current Access: read-only
OBJECT-TYPE    
  PrvtSyncEthernetQualityLevelType  

syncEthernetClockOutputLastQualityLevelChange 1.3.6.1.4.1.738.1.5.170.1.12.1.7
Time elapsed since the last quality level change
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

syncEthernetClockOutputMsgEvent 1.3.6.1.4.1.738.1.5.170.1.12.1.8
Last ESMC message type sent
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

syncEthernetClockOutputNumTransmittedEsmcPdu 1.3.6.1.4.1.738.1.5.170.1.12.1.9
Total number of ESMC messages sent
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

syncEthernetClockOutputNumTransmittedEventEsmcPdu 1.3.6.1.4.1.738.1.5.170.1.12.1.10
Total number of ESMC messages sent
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

syncEthernetDpllTable 1.3.6.1.4.1.738.1.5.170.1.14
Synchronization DPLL table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SyncEthernetDpllEntry

syncEthernetDpllEntry 1.3.6.1.4.1.738.1.5.170.1.14.1
Synchronization DPLL entry
Status: current Access: not-accessible
OBJECT-TYPE    
  SyncEthernetDpllEntry  

syncEthernetDpllModuleId 1.3.6.1.4.1.738.1.5.170.1.14.1.1
Synchronization DPLL module index
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..1  

syncEthernetDpllRowStatus 1.3.6.1.4.1.738.1.5.170.1.14.1.2
Synchronization DPLL rowstatus
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

syncEthernetDpllAdminStatus 1.3.6.1.4.1.738.1.5.170.1.14.1.3
Administrative status of the DPLL
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER up(1), down(2)  

syncEthernetDpllReferenceSelection 1.3.6.1.4.1.738.1.5.170.1.14.1.4
Specify reference selection mode
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER freerun(1), static(2), g781(3)  

syncEthernetDpllEnableQualityLevel 1.3.6.1.4.1.738.1.5.170.1.14.1.5
Enable reference selection based on quality level Only applicable when syncEthernetDpllReferenceSelection equals g781.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

syncEthernetDpllStatusChangeNotify 1.3.6.1.4.1.738.1.5.170.1.14.1.6
Enable DPLL status change notifications
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

syncEthernetDpllReferenceChangeNotify 1.3.6.1.4.1.738.1.5.170.1.14.1.7
Enable reference clock change notifications
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

syncEthernetDpllStatus 1.3.6.1.4.1.738.1.5.170.1.14.1.8
DPLL operational status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER freerun(0), locked(1), holdover(2), refFailure(3)  

syncEthernetDpllStatusLastChange 1.3.6.1.4.1.738.1.5.170.1.14.1.9
Time since last DPLL status change
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

syncEthernetDpllSystemQualityLevel 1.3.6.1.4.1.738.1.5.170.1.14.1.10
System quality level
Status: current Access: read-only
OBJECT-TYPE    
  PrvtSyncEthernetQualityLevelType  

syncEthernetDpllSystemQualityLevelLastChange 1.3.6.1.4.1.738.1.5.170.1.14.1.11
Time since last system quality level change
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

syncEthernetDpllSelectedReferenceClock 1.3.6.1.4.1.738.1.5.170.1.14.1.12
The selected reference clock source
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

syncEthernetDpllSelectedReferenceClockChange 1.3.6.1.4.1.738.1.5.170.1.14.1.13
Time since last reference clock change
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

syncEthernetDpllClkRefTable 1.3.6.1.4.1.738.1.5.170.1.16
Synchronization DPLL clock reference table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SyncEthernetDpllClkRefEntry

syncEthernetDpllClkRefEntry 1.3.6.1.4.1.738.1.5.170.1.16.1
Synchronization DPLL clock reference entry
Status: current Access: not-accessible
OBJECT-TYPE    
  SyncEthernetDpllClkRefEntry  

syncEthernetDpllClkRefRowStatus 1.3.6.1.4.1.738.1.5.170.1.16.1.2
Synchronization DPLL clock reference rowstatus
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

syncEthernetDpllClkRefPriority 1.3.6.1.4.1.738.1.5.170.1.16.1.3
Specify reference clock priority
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..256  

syncEthernetDpllClkRefLockOut 1.3.6.1.4.1.738.1.5.170.1.16.1.4
Lock reference clock
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

syncEthernetDpllClkRefFailStatus 1.3.6.1.4.1.738.1.5.170.1.16.1.5
DPLL reference clock status
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

syncEthernetInvalidESMC 1.3.6.1.4.1.738.1.5.170.0.1
Invalid ESMC has been received.
Status: current Access: read-only
NOTIFICATION-TYPE    

syncEthernetQualityLevelChange 1.3.6.1.4.1.738.1.5.170.0.2
Current value of syncEthernetClockSourceQuality has been changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

syncEthernetInvalidQualityLevelReceived 1.3.6.1.4.1.738.1.5.170.0.3
Invalid Quality level equals to QL-INVx has been received.
Status: current Access: read-only
NOTIFICATION-TYPE    

syncEthernetDPLLReferenceChange 1.3.6.1.4.1.738.1.5.170.0.4
DPLL's reference clock changed.
Status: current Access: read-only
NOTIFICATION-TYPE    

syncEthernetDPLLChanged 1.3.6.1.4.1.738.1.5.170.0.5
Some of the DPLL's operational status changes.
Status: current Access: read-only
NOTIFICATION-TYPE    

syncEthernetDPLLLockFailed 1.3.6.1.4.1.738.1.5.170.0.6
If after new Reference selection the DPLL can't lock onto it, this will affect the Clock Source associated with that reference
Status: current Access: read-only
NOTIFICATION-TYPE