QB-DWS-MIB

File: QB-DWS-MIB.mib (60348 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IF-MIB QUANTUMBRIDGE-REG QBSYS-SYSTEM-MIB
ATM-TC-MIB

Imported symbols

NOTIFICATION-TYPE MODULE-IDENTITY OBJECT-TYPE
Gauge32 Counter32 Unsigned32
Integer32 TimeTicks IpAddress
TEXTUAL-CONVENTION TruthValue TimeStamp
RowStatus DisplayString MODULE-COMPLIANCE
OBJECT-GROUP InterfaceIndex InterfaceIndexOrZero
ifIndex qbMibs qbSysModuleSlot
qbSysIotSerialNumber AtmAddr AtmConnKind
AtmConnCastType AtmServiceCategory AtmTrafficDescrParamIndex
AtmVpIdentifier AtmVcIdentifier AtmVorXAdminStatus
AtmVorXLastChange AtmVorXOperStatus atmNoClpNoScr

Defined Types

QbPvcConnKind  
A connection type that can be provisioned.
TEXTUAL-CONVENTION    
  INTEGER unknown(0), atmPvcToPvc(1), atmPvpToPvp(2), iotE1ToAtm(3), iotDs1ToAtm(4), iotEnetToAtm(5), vt15ToAtm(6), vc12ToAtm(7), vt15Vt15(8), vc12ToVc12(9), iotE1ToVt15(10), iotDs1ToVt15(11), iotE1ToVc12(12), iotDs1ToVc12(13), iotE1ToIotE1(14), iotDs1ToIotDs1(15), iotEnetToIotEnet(16), vc11ToAtm(17), iotDs1ToVc11(18), vc11ToVc11(19), m13ToAtm(20), iotDs1ToM13(21), m13ToM13(22), atmToEnet(23), atmToDs1(24), atmToE1(25), ds1ToVt15(26), e1ToVc12(27), ds1ToVc11(28), ds1ToM13(29), ds1ToDs1(30), e1ToE1(31), enetToEnet(32), iotDs1ToDs1(33), iotE1ToE1(34), iotEnetToEnet(35), vlanToAtm(36), vlanToGige(37), vlanToIotEnet(38), vlanToEnet(39)  

QbBitRate  
A data rate in bits/second.
TEXTUAL-CONVENTION    
  Gauge32  

QbSerialNum  
The IOT serial number.
TEXTUAL-CONVENTION    
  Unsigned32 0..32  

QbDwsIfStatus  
The status of the DWS Interface
TEXTUAL-CONVENTION    
  INTEGER ok(1), rxFailure(2), txFailure(3), unknown(4)  

QbDwsSrvStatus  
The service status of the DWS Interface
TEXTUAL-CONVENTION    
  INTEGER avilable(1), empty(2), almostFull(3), overflown(4)  

QbAtmAal5EncapsType  
The type of data encapsulation used over the AAL5 layer.
TEXTUAL-CONVENTION    
  INTEGER qbVcMultiplexRoutedProto(1), qbBridgedProto8023EncapFcs(2), qbBridgedProto8023EncapsNoFcs(3), qbBridgedPropEncaps(4), qbBridgedProtoLLCEncapsNoFcs(5), qbRoutedEncapsNoHdrNoFcs(6)  

QbEnableStatus  
enable(1) or disable(1) operations.
TEXTUAL-CONVENTION    
  INTEGER enable(1), disable(2)  

QbDwsNetEntry  
SEQUENCE    
  qbDwsNetIfIndex InterfaceIndex
  qbDwsNetBw QbBitRate
  qbDwsNetAllocatedBw QbBitRate
  qbDwsNetAvailableBw QbBitRate
  qbDwsNetAllocatedUbrBw QbBitRate
  qbDwsNetAllocatedCbrBw QbBitRate
  qbDwsNetNumCbrConn Integer32
  qbDwsNetNumUbrConn Integer32
  qbDwsNetNumIot Integer32
  qbDwsNetTxStatus QbDwsIfStatus
  qbDwsNetTxStatusLastChange TimeStamp
  qbDwsNetLosIotAddr Integer32
  qbDwsNetLosIotTime TimeStamp
  qbDwsNetEncryptStatus TruthValue
  qbDwsNetRangeMode INTEGER
  qbDwsNetRxTsCount Counter32
  qbDwsNetTxTsCount Counter32
  qbDwsNetRxMissingTs Counter32
  qbDwsNetRxIllegalTs Counter32
  qbDwsNetTxJabberTs Counter32
  qbDwsNetTxOutOfFrameTs Counter32
  qbDwsNetTxHdrCrcTsErrs Counter32
  qbDwsNetOamRequests Counter32
  qbDwsNetOamResponses Counter32
  qbDwsNetOamEvents Counter32
  qbDwsNetOamBadMsgs Counter32
  qbDwsNetLoopBack INTEGER

QbDwsIotIfConfEntry  
SEQUENCE    
  qbDwsIotIfIndex InterfaceIndex
  qbDwsIotNetIfIndex InterfaceIndex
  qbDwsIotIfAddr Integer32
  qbDwsIotIfConfPowerLevel Integer32
  qbDwsIotIfConfEqDelay TimeTicks
  qbDwsIotIfConfWaveLength Integer32
  qbDwsIotIfUbrBw QbBitRate
  qbDwsIotIfCbrBw QbBitRate
  qbDwsIotIfTxStatus QbDwsIfStatus
  qbDwsIotIfTxStatusLastChange TimeStamp
  qbDwsIotIfLastRangeTime TimeStamp

QbDwsIotIfStatsEntry  
SEQUENCE    
  qbDwsIotIfStatsUtil INTEGER
  qbDwsIotIfStatsOamRequests Counter32
  qbDwsIotIfStatsOamResponses Counter32
  qbDwsIotIfStatsOamEvents Counter32
  qbDwsIotIfStatsOamBadMsgs Counter32
  qbDwsIotIfStatsCrcErrs Counter32
  qbDwsIotIfStatsTsHdrParityErrs Counter32
  qbDwsIotIfStatsFrameLossErrs Counter32
  qbDwsIotIfStatsSignalLossErrs Counter32
  qbDwsIotIfStatsRxAal1Cells Counter32
  qbDwsIotIfStatsTxAal1Cells Counter32

QbIotPktIfConfEntry  
SEQUENCE    
  qbIotPktIfConfIndex InterfaceIndex
  qbAtmIfIndex InterfaceIndex
  qbIotPktIfConfVpi AtmVpIdentifier
  qbIotPktIfConfVci AtmVcIdentifier
  qbIotPktIfConfConnName DisplayString
  qbIotPktIfConfRxTrafficDescrIndex AtmTrafficDescrParamIndex
  qbIotPktIfConfTxTrafficDescrIndex AtmTrafficDescrParamIndex
  qbIotPktIfConfAdminStatus AtmVorXAdminStatus
  qbIotPktIfConfOperStatus AtmVorXOperStatus
  qbIotPktIfConfRowStatus RowStatus
  qbIotPktIfConfLoopback QbEnableStatus
  qbIotPktIfConfConnKind QbPvcConnKind

QbIotAddrEntry  
SEQUENCE    
  qbIotAddr Integer32
  qbIotSerialNum QbSerialNum

QbIotPortCrossConnEntry  
SEQUENCE    
  qbIotPortCrossConnEndpt1IfIndex InterfaceIndex
  qbIotPortCrossConnEndpt2IfIndex InterfaceIndex
  qbIotPortCrossConnAdminStatus AtmVorXAdminStatus
  qbIotPortCrossConnOperStatus AtmVorXOperStatus
  qbIotPortCrossConnLastChange AtmVorXLastChange
  qbIotPortCrossConnRxTrafficDescrIndex AtmTrafficDescrParamIndex
  qbIotPortCrossConnTxTrafficDescrIndex AtmTrafficDescrParamIndex
  qbIotPortCrossConnName DisplayString
  qbIotPortCrossConnRowStatus RowStatus
  qbIotPortCrossConnLoopback QbEnableStatus
  qbIotPortCrossConnLoopbackEndpt INTEGER
  qbIotPortCrossConnKind QbPvcConnKind

QbTContEntry  
SEQUENCE    
  qbTContIndex INTEGER
  qbTContType INTEGER
  qbTContMaxBw INTEGER
  qbTContFixedBw INTEGER
  qbTContAssuredBw INTEGER
  qbTContGrantNum INTEGER

Defined Values

qbDwsMIB 1.3.6.1.4.1.4323.2.3
This module defines additional objects for the provisioning and management of DWS links in Quantum bridge devices.
MODULE-IDENTITY    

qbDwsObjects 1.3.6.1.4.1.4323.2.3.1
OBJECT IDENTIFIER    

qbDwsNotifications 1.3.6.1.4.1.4323.2.3.2
OBJECT IDENTIFIER    

qbDwsConformance 1.3.6.1.4.1.4323.2.3.3
OBJECT IDENTIFIER    

qbDwsNetGroup 1.3.6.1.4.1.4323.2.3.1.1
OBJECT IDENTIFIER    

qbDwsIotIfGroup 1.3.6.1.4.1.4323.2.3.1.2
OBJECT IDENTIFIER    

qbIotPktIfGroup 1.3.6.1.4.1.4323.2.3.1.3
OBJECT IDENTIFIER    

qbIotAddrGroup 1.3.6.1.4.1.4323.2.3.1.4
OBJECT IDENTIFIER    

qbIotPortCrossConnGroup 1.3.6.1.4.1.4323.2.3.1.5
OBJECT IDENTIFIER    

qbTContGroup 1.3.6.1.4.1.4323.2.3.1.6
OBJECT IDENTIFIER    

qbDwsSysRangeMode 1.3.6.1.4.1.4323.2.3.1.1.1
The object that indicates a system wide range mode. When read, this object always returns the value 'ready(1)'. Setting this object to rangeAll(2) causes ranging of all IOTs that connect to this OAS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), rangeAll(2)  

qbSysIotRecoverMode 1.3.6.1.4.1.4323.2.3.1.1.2
The object allows to set the IOT auto-recovery feature on the IOAS. Auto-recovery is global in scope, so when it is enabled, auto-recovery is attempted for all IOTs that are attached to the IOAS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

qbDwsNetTable 1.3.6.1.4.1.4323.2.3.1.1.3
The Quantum Bridge PON Interface Table contains extensions of the standard MIB Interface Table, one entry per IOAS DWS interface. The table contains read-only objects and shows MIB objects for every Network interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    QbDwsNetEntry

qbDwsNetEntry 1.3.6.1.4.1.4323.2.3.1.1.3.1
An entry in the Quantum Bridge DWS Interface Table that contains the Network interface's specific objects.
Status: current Access: not-accessible
OBJECT-TYPE    
  QbDwsNetEntry  

qbDwsNetIfIndex 1.3.6.1.4.1.4323.2.3.1.1.3.1.1
The value of this object is the same as the corresponding ifIndex of the Network Interface in the ifTable.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

qbDwsNetBw 1.3.6.1.4.1.4323.2.3.1.1.3.1.2
The object indicates the total bandwidth rate that is available for reservation on this interface. This object is specified in Bits per second.
Status: current Access: read-only
OBJECT-TYPE    
  QbBitRate  

qbDwsNetAllocatedBw 1.3.6.1.4.1.4323.2.3.1.1.3.1.3
The object indicates the total bandwidth rate that is currently subscribed. The subscribed bandwidth rate consists of the bandwidth rate allocated for all provisoned connections. This object is specified in Bits per sec(Bps).
Status: current Access: read-only
OBJECT-TYPE    
  QbBitRate  

qbDwsNetAvailableBw 1.3.6.1.4.1.4323.2.3.1.1.3.1.4
The portion of this interface's capacity in bits per sec that is available for data traffic. This variable is adjusted for the allocated bandwidth. The formula for calculating this value is qbDwsNetBw - qbDwsNetAllocatedBw This object is specified in Bps.
Status: current Access: read-only
OBJECT-TYPE    
  QbBitRate  

qbDwsNetAllocatedUbrBw 1.3.6.1.4.1.4323.2.3.1.1.3.1.5
The object indicates the total number of bandwidth that are currently allocated for packet/ubr traffic. This object is specified in Bps.
Status: current Access: read-only
OBJECT-TYPE    
  QbBitRate  

qbDwsNetAllocatedCbrBw 1.3.6.1.4.1.4323.2.3.1.1.3.1.6
The object indicates the total number of bandwidth that is currently allocated for CBR traffic. This object is specified in Bps.
Status: current Access: read-only
OBJECT-TYPE    
  QbBitRate  

qbDwsNetNumCbrConn 1.3.6.1.4.1.4323.2.3.1.1.3.1.7
The object indicates the total number of inactive and in-service CBR connections that are currently provisioned on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

qbDwsNetNumUbrConn 1.3.6.1.4.1.4323.2.3.1.1.3.1.8
The object indicates the total number of inactive and in-serice UBR connections that are currently provisioned on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

qbDwsNetNumIot 1.3.6.1.4.1.4323.2.3.1.1.3.1.9
The number of IOTs that are provisioned on the Network interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

qbDwsNetTxStatus 1.3.6.1.4.1.4323.2.3.1.1.3.1.10
This objects indicates the status of the DWS transmitter. The trap is generated by the SNMP agent when the IOAS DWS transmitter problem is detected. The trap contains the DWS module interface index.
Status: current Access: read-only
OBJECT-TYPE    
  QbDwsIfStatus  

qbDwsNetTxStatusLastChange 1.3.6.1.4.1.4323.2.3.1.1.3.1.11
The value of MIB II's sysUpTime object at the time this DWS Interface entered its current status state.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

qbDwsNetLosIotAddr 1.3.6.1.4.1.4323.2.3.1.1.3.1.12
The object contains the address of the IOT for which a Los condition is detected. This indicates that no signal was detected within the expected time slot window. Note: The Los indication at the IOAS DWS card is a signal that an IOT is non-functioning.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

qbDwsNetLosIotTime 1.3.6.1.4.1.4323.2.3.1.1.3.1.13
The value of MIB II's sysUpTime object at the time when the qbDwsNetIotLos condition was detected.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

qbDwsNetEncryptStatus 1.3.6.1.4.1.4323.2.3.1.1.3.1.14
The object that enables and disables encryption on this interface.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

qbDwsNetRangeMode 1.3.6.1.4.1.4323.2.3.1.1.3.1.15
The object that indicates a range mode. When read, this object always returns the value 'ready(1)'. Setting this object to rangeAll(2) causes ranging of all IOTs connected to this interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), rangeAll(2)  

qbDwsNetRxTsCount 1.3.6.1.4.1.4323.2.3.1.1.3.1.16
The total number of successfully received time slots.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsNetTxTsCount 1.3.6.1.4.1.4323.2.3.1.1.3.1.17
The total number of successfully transmitted time slots.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsNetRxMissingTs 1.3.6.1.4.1.4323.2.3.1.1.3.1.18
The number received time slots that have been missed.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsNetRxIllegalTs 1.3.6.1.4.1.4323.2.3.1.1.3.1.19
The number illegal received time slots that have been detected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsNetTxJabberTs 1.3.6.1.4.1.4323.2.3.1.1.3.1.20
The number jabber transmitted time slots that have been detected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsNetTxOutOfFrameTs 1.3.6.1.4.1.4323.2.3.1.1.3.1.21
The number out of frame transmitted timeslots that have been detected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsNetTxHdrCrcTsErrs 1.3.6.1.4.1.4323.2.3.1.1.3.1.22
The number transmitted timeslots with the header protection error that have been detected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsNetOamRequests 1.3.6.1.4.1.4323.2.3.1.1.3.1.23
The number of OAM requests. These OAM requests are originated by the IOAS and sent to downstream IOTs.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsNetOamResponses 1.3.6.1.4.1.4323.2.3.1.1.3.1.24
The number of OAM responses. These responses are generated by IOTs in response to downstream requests.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsNetOamEvents 1.3.6.1.4.1.4323.2.3.1.1.3.1.25
The number of OAM events. These events are originated by IOT devices to signal abnormal conditions.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsNetOamBadMsgs 1.3.6.1.4.1.4323.2.3.1.1.3.1.26
The total number of bad OAM messages.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsNetLoopBack 1.3.6.1.4.1.4323.2.3.1.1.3.1.27
The Loopback status of this DWS port. Writing configures the port to go into the loopback mode. When placed in loopback mode the DWS port does a 'payload' loopback.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

qbDwsIotIfConfTable 1.3.6.1.4.1.4323.2.3.1.2.1
The Quantum DWS interface table. One entry per each IOT's DWS interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    QbDwsIotIfConfEntry

qbDwsIotIfConfEntry 1.3.6.1.4.1.4323.2.3.1.2.1.1
An entry in the Quantum Bridge DWS Interface Table. The ifIndex is a DWS interface index from ifTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  QbDwsIotIfConfEntry  

qbDwsIotIfIndex 1.3.6.1.4.1.4323.2.3.1.2.1.1.1
The ifIndex of this interface in the ifTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

qbDwsIotNetIfIndex 1.3.6.1.4.1.4323.2.3.1.2.1.1.2
The ifIndex of this PON interface in the ifTable.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

qbDwsIotIfAddr 1.3.6.1.4.1.4323.2.3.1.2.1.1.3
The IOT terminal address.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

qbDwsIotIfConfPowerLevel 1.3.6.1.4.1.4323.2.3.1.2.1.1.4
The DWS interface's power level.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

qbDwsIotIfConfEqDelay 1.3.6.1.4.1.4323.2.3.1.2.1.1.5
The equal Delay time (in hundredths of a second).
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

qbDwsIotIfConfWaveLength 1.3.6.1.4.1.4323.2.3.1.2.1.1.6
The wave length value for this DWS interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

qbDwsIotIfUbrBw 1.3.6.1.4.1.4323.2.3.1.2.1.1.7
The object indicates the total UBR bandwidth rate that is reserved for a given IOT interface. This object is specified in Bits per second.
Status: current Access: read-only
OBJECT-TYPE    
  QbBitRate  

qbDwsIotIfCbrBw 1.3.6.1.4.1.4323.2.3.1.2.1.1.8
The object indicates the total CBR bandwidth rate that is reserved for a given IOT interface. This object is specified in Bits per second.
Status: current Access: read-only
OBJECT-TYPE    
  QbBitRate  

qbDwsIotIfTxStatus 1.3.6.1.4.1.4323.2.3.1.2.1.1.9
This objects indicates the status of the IOT DWS Port. The txFailure(2) state indicates that the laser transmitter failed. The rxFailure(3) state indicates that no signal was detected within the expected timeslot window. It signals that there is a problem with the DWS port receiver. When this object is changed, the ifOperStatus and ifLastChnaged of this interface must also be changed. Note: The trap is generated by the SNMP agent when the IOT DWS status is changed. The trap contains the IOAS DWS card interface index and IOT address.
Status: current Access: read-only
OBJECT-TYPE    
  QbDwsIfStatus  

qbDwsIotIfTxStatusLastChange 1.3.6.1.4.1.4323.2.3.1.2.1.1.10
The value of MIB II's sysUpTime object at the time this DWS Interface enters its current status state.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

qbDwsIotIfLastRangeTime 1.3.6.1.4.1.4323.2.3.1.2.1.1.11
The value of MIB II's sysUpTime object at the last time when this IOT is ranged
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

qbDwsIotIfStatsTable 1.3.6.1.4.1.4323.2.3.1.2.2
The Quantum Bridge IOT's terminal table. One entry per each RT.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    QbDwsIotIfStatsEntry

qbDwsIotIfStatsEntry 1.3.6.1.4.1.4323.2.3.1.2.2.1
An entry in the Quantum DWS Interface Statistics Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  QbDwsIotIfStatsEntry  

qbDwsIotIfStatsUtil 1.3.6.1.4.1.4323.2.3.1.2.2.1.1
The object indicates the utilization of the Network Interface transmission rate capacity by the IOT DWS interface. This object is specified in percents.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

qbDwsIotIfStatsOamRequests 1.3.6.1.4.1.4323.2.3.1.2.2.1.2
The number of received downstream OAM request messages.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsIotIfStatsOamResponses 1.3.6.1.4.1.4323.2.3.1.2.2.1.3
The number of transmitted upstream OAM response messages.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsIotIfStatsOamEvents 1.3.6.1.4.1.4323.2.3.1.2.2.1.4
The number of OAM event messages originated by the interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsIotIfStatsOamBadMsgs 1.3.6.1.4.1.4323.2.3.1.2.2.1.5
The number of wrong OAM messages received on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsIotIfStatsCrcErrs 1.3.6.1.4.1.4323.2.3.1.2.2.1.6
The summary number of the IOT DWS CRC subframe and time slot header CRC errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsIotIfStatsTsHdrParityErrs 1.3.6.1.4.1.4323.2.3.1.2.2.1.7
The number of Time Slot header parity errors that have been detected on the interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsIotIfStatsFrameLossErrs 1.3.6.1.4.1.4323.2.3.1.2.2.1.8
The number of Loss frame errors that have been detected on the interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsIotIfStatsSignalLossErrs 1.3.6.1.4.1.4323.2.3.1.2.2.1.9
The number of Loss signal errors that have been detected on the interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsIotIfStatsRxAal1Cells 1.3.6.1.4.1.4323.2.3.1.2.2.1.10
The number of received AAL1 ATM cells.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbDwsIotIfStatsTxAal1Cells 1.3.6.1.4.1.4323.2.3.1.2.2.1.11
The number of transmitted ATM cells .
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

qbIotPktIfConfTable 1.3.6.1.4.1.4323.2.3.1.3.1
The Quantum Bridge PKT configuration table contains cross-connections between Ethernet interfaces and corresponding PVC/AAL5 that are configured at a WAN port. An entry in the table may be created, destroyed or modified. This table lists all PVCs within the System that send/receive packet traffic to/from the ATM cloud.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    QbIotPktIfConfEntry

qbIotPktIfConfEntry 1.3.6.1.4.1.4323.2.3.1.3.1.1
An entry in the Quantum Bridge IP configuration table. For every IP traffic flow, there is a corresponding row in this table which contains a DWS interface index, and a VPI/VCI pair of PVC configured at a SONET port for a given DWS interface. The creation of a row in this table causes a corresponding entry in the atmVclTable of the ATM-MIB to be automatically created if an atmVclEntry with qbPktIotIfConfVpi and qbPktIotIfConfVci values does not exist. This corresponding entry can be removed only if the qbPktIotIfConfEntry is removed. The qbPktIotIfConfIndex of this table is an ifIndex of the DWS interface from the ifTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  QbIotPktIfConfEntry  

qbIotPktIfConfIndex 1.3.6.1.4.1.4323.2.3.1.3.1.1.1
An interface index of the Ethernet port interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

qbAtmIfIndex 1.3.6.1.4.1.4323.2.3.1.3.1.1.2
An interface index of the ATM interface that is stacked on top of the WAN/SONET interface.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndex  

qbIotPktIfConfVpi 1.3.6.1.4.1.4323.2.3.1.3.1.1.3
A VPI of the AAL5 PVC that connects this interface to the ATM cloud. This PVC is automatically configured at the SONET port of the WAN card (atmVclTable).
Status: current Access: read-create
OBJECT-TYPE    
  AtmVpIdentifier  

qbIotPktIfConfVci 1.3.6.1.4.1.4323.2.3.1.3.1.1.4
A VCI of the AAL5 bi-directional PVC that connects this interface to the ATM cloud. This PVC is automatically configured or removed at the SONET port of the WAN card (atmVclTable).
Status: current Access: read-create
OBJECT-TYPE    
  AtmVcIdentifier  

qbIotPktIfConfConnName 1.3.6.1.4.1.4323.2.3.1.3.1.1.5
The textual name of the connection(PVC) as specified by a user. It provides a non-volatile handle for this PVC. The supplied name in the qbPktIotIfConfPvcName is associated with the same PVC for as long as that PVC/conection remains.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(1..20)  

qbIotPktIfConfRxTrafficDescrIndex 1.3.6.1.4.1.4323.2.3.1.3.1.1.6
The value of this object identifies the row of the ATM Traffic Descriptor Table which applies to the transmit direction of this VCL.
Status: current Access: read-create
OBJECT-TYPE    
  AtmTrafficDescrParamIndex  

qbIotPktIfConfTxTrafficDescrIndex 1.3.6.1.4.1.4323.2.3.1.3.1.1.7
The value of this object identifies the row in the ATM Traffic Descriptor Table which applies to the receive direction of this VCL.
Status: current Access: read-create
OBJECT-TYPE    
  AtmTrafficDescrParamIndex  

qbIotPktIfConfAdminStatus 1.3.6.1.4.1.4323.2.3.1.3.1.1.8
The desired administrative status of the packet connection The up and down states indicate that the traffic flow is enabled or disabled respectively across the ATM cloud.
Status: current Access: read-create
OBJECT-TYPE    
  AtmVorXAdminStatus  

qbIotPktIfConfOperStatus 1.3.6.1.4.1.4323.2.3.1.3.1.1.9
The current operational status of the connect.
Status: current Access: read-only
OBJECT-TYPE    
  AtmVorXOperStatus  

qbIotPktIfConfRowStatus 1.3.6.1.4.1.4323.2.3.1.3.1.1.10
The status column for this IOT ENET interface. This OBJECT can be set to: createAndGo(4) destroy(6) The following values may be read: active(1) This object may only be set to createAndGo(4). Setting this object to active(1) when its value is already active(1) is a no-op. Setting this object to createAndGo(4) causes the agent to attempt to create and commit the row based on the contents of the objects in the row. If all necessary information is present in the row and the values are acceptable to the agent, the agent will change the status to active(1). If any of the necessary objects are not available, the agent will reject the creation request. Setting this object to destroy(6) will remove the corresponding entry in this table, and disable data traffic.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

qbIotPktIfConfLoopback 1.3.6.1.4.1.4323.2.3.1.3.1.1.11
This object enables loopback on the IOT ENET enedpoint.
Status: current Access: read-create
OBJECT-TYPE    
  QbEnableStatus  

qbIotPktIfConfConnKind 1.3.6.1.4.1.4323.2.3.1.3.1.1.12
The PVC connection type.
Status: current Access: read-create
OBJECT-TYPE    
  QbPvcConnKind  

qbIotAddrTable 1.3.6.1.4.1.4323.2.3.1.4.1
The Quantum Bridge IOT address table. This table contains information to convert an IOT's address into an IOT's serial number. This table has two indexes: 1. Interface index of the IOAS interface to which a terminal connects. The interface identified by a particular value of this index is the same as the interface identified by the same value of ifIndex. 2. IOT terminal address. A row exists in this table for each discovered IOT terminal. Whenever an IOT is discovered a row is added to the table
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    QbIotAddrEntry

qbIotAddrEntry 1.3.6.1.4.1.4323.2.3.1.4.1.1
For every IOT terminal there is a row in this table. This contains the IOT address and serial number.
Status: current Access: not-accessible
OBJECT-TYPE    
  QbIotAddrEntry  

qbIotAddr 1.3.6.1.4.1.4323.2.3.1.4.1.1.1
The IOT's address.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

qbIotSerialNum 1.3.6.1.4.1.4323.2.3.1.4.1.1.2
The IOT's serial number.
Status: current Access: read-only
OBJECT-TYPE    
  QbSerialNum  

qbIotPortCrossConnTable 1.3.6.1.4.1.4323.2.3.1.5.1
The Quantum Bridge IOT port cross-connection table. This table defines all IOT port point-to-point cross-connections within a single OAS system. The connection can be set between two Ethernet, two DS1 or two E1 ports on different IOTs. The table has two indexes: the interface index of the first end-point and the interface index of the second endpoint. Note: Connections that are listed in this table are not reflected in the atmVclTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    QbIotPortCrossConnEntry

qbIotPortCrossConnEntry 1.3.6.1.4.1.4323.2.3.1.5.1.1
An entry in the Quantum Bridge qbIotPortConnTable two contains a connection between the same port type of different IOTs.
Status: current Access: not-accessible
OBJECT-TYPE    
  QbIotPortCrossConnEntry  

qbIotPortCrossConnEndpt1IfIndex 1.3.6.1.4.1.4323.2.3.1.5.1.1.1
The ifIndex of the first IOT port((end-point) for the configured IOT cross-connect.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

qbIotPortCrossConnEndpt2IfIndex 1.3.6.1.4.1.4323.2.3.1.5.1.1.2
The ifIndex of the second IOT port(end-point) for the configured IOT cross-connect.
Status: current Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

qbIotPortCrossConnAdminStatus 1.3.6.1.4.1.4323.2.3.1.5.1.1.3
The value of this object identifies the row in the ATM Traffic Descriptor Table which applies to the receive direction of this VCL.
Status: current Access: read-create
OBJECT-TYPE    
  AtmVorXAdminStatus  

qbIotPortCrossConnOperStatus 1.3.6.1.4.1.4323.2.3.1.5.1.1.4
The current operational status of the connection.
Status: current Access: read-only
OBJECT-TYPE    
  AtmVorXOperStatus  

qbIotPortCrossConnLastChange 1.3.6.1.4.1.4323.2.3.1.5.1.1.5
The value of sysUpTime at the time this connection entered its current operational state.
Status: current Access: read-only
OBJECT-TYPE    
  AtmVorXLastChange  

qbIotPortCrossConnRxTrafficDescrIndex 1.3.6.1.4.1.4323.2.3.1.5.1.1.6
The value of this object identifies the row of the ATM Traffic Descriptor Table which applies to the transmit direction of this connection.
Status: current Access: read-create
OBJECT-TYPE    
  AtmTrafficDescrParamIndex  

qbIotPortCrossConnTxTrafficDescrIndex 1.3.6.1.4.1.4323.2.3.1.5.1.1.7
The value of this object identifies the row in the ATM Traffic Descriptor Table which applies to the receive direction of this connection.
Status: current Access: read-create
OBJECT-TYPE    
  AtmTrafficDescrParamIndex  

qbIotPortCrossConnName 1.3.6.1.4.1.4323.2.3.1.5.1.1.8
The textual name of the connection as specified by a user. It provides a non-volatile handle for this connection. The supplied name in the qbIotPortConnName is associated with the same connection for as long as that conection remains.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..20)  

qbIotPortCrossConnRowStatus 1.3.6.1.4.1.4323.2.3.1.5.1.1.9
The status of the port connect entry. Changing the value of this object from 'active' to 'destroy' will remove this entry from the database. It will disrupt traffic between two IOT packet interfaces.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

qbIotPortCrossConnLoopback 1.3.6.1.4.1.4323.2.3.1.5.1.1.10
This object enables loopback on this IOT to IOT port enedpoint. The endpoint on which loopback is enabled is defined by qbIotPortCrossConnLoopbackEndpt.
Status: current Access: read-create
OBJECT-TYPE    
  QbEnableStatus  

qbIotPortCrossConnLoopbackEndpt 1.3.6.1.4.1.4323.2.3.1.5.1.1.11
This object defines loopback on the selected endpoint.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER endPt1(1), endPt2(2)  

qbIotPortCrossConnKind 1.3.6.1.4.1.4323.2.3.1.5.1.1.12
The VCL connection type.
Status: current Access: read-create
OBJECT-TYPE    
  QbPvcConnKind  

qbTContNumber 1.3.6.1.4.1.4323.2.3.1.6.1
The total number of provisioned Ethernet to ATM PVCs.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

qbNextFreeTContIndex 1.3.6.1.4.1.4323.2.3.1.6.2
The next available Container index.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

qbTContTable 1.3.6.1.4.1.4323.2.3.1.6.3
The Quantum Bridge Traffic Container table(TCons) contains traffic containers of IOTs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    QbTContEntry

qbTContEntry 1.3.6.1.4.1.4323.2.3.1.6.3.1
An entry in the qbTContTable. There is one entry in the table per IOT on the PON for Release 3.0. The creation of a row in the qbSysIotTable causes a corresponding entry in this table to be automatically created. The deletion of a row in the qbSysIotTable causes a corresponding entry in this table to be automatically removed.
Status: current Access: not-accessible
OBJECT-TYPE    
  QbTContEntry  

qbTContIndex 1.3.6.1.4.1.4323.2.3.1.6.3.1.1
The value of this object identifies the row of the Traffic Container Table. Note tht this value can be set to 1 only for Release 3.0.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER  

qbTContType 1.3.6.1.4.1.4323.2.3.1.6.3.1.2
The Traffic container type. Note that this object can be set to type1 for Release 3.0
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER type1(1), type2(2), type3(3), type4(4), type5(5)  

qbTContMaxBw 1.3.6.1.4.1.4323.2.3.1.6.3.1.3
The maximum bandwidth to be assigned to this TCONT. Note that the read-only access is supported for Release 3.0
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

qbTContFixedBw 1.3.6.1.4.1.4323.2.3.1.6.3.1.4
The lower limit of bandwidth for this TCONT.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

qbTContAssuredBw 1.3.6.1.4.1.4323.2.3.1.6.3.1.5
The guaranteed minimum bandwidth for this TCONT. TCONT. Note that the read-only access is supported for Release 3.0
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

qbTContGrantNum 1.3.6.1.4.1.4323.2.3.1.6.3.1.6
FSAN grant number that is assigned to this TCONT. Note that the read-only access is supported for Release 3.0
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

qbDwsNotificationPrefix 1.3.6.1.4.1.4323.2.3.2.0
OBJECT IDENTIFIER    

qbDwsIotRxLos 1.3.6.1.4.1.4323.2.3.2.0.1
A qbDwsIotRxLos trap indicates Loss of Signal by the IOT's. This trap is generated by an IOT when Analog DS1/E1 Analog or Digital Los occur.
Status: current Access: read-write
NOTIFICATION-TYPE    

qbDwsRxIoasLos 1.3.6.1.4.1.4323.2.3.2.0.2
A qbDwsRxIoasLos trap indicates Loss of Signal by the IOAS's DWS receiver. This trap is generated by an IOAS DWS card when no signal from an IOT is detected within the timeslot window.
Status: current Access: read-write
NOTIFICATION-TYPE    

qbDwsIoasTxFailure 1.3.6.1.4.1.4323.2.3.2.0.3
A qbDwsTxFailure trap indicates that the IOAS card transmitter does not work. The trap is generated by an IOAS card when the IOAS DWS card transmitter problem is detected. The trap contains the DWS card interface index.
Status: current Access: read-write
NOTIFICATION-TYPE    

qbDwsIotRangeTimeout 1.3.6.1.4.1.4323.2.3.2.0.4
A qbDwsTxFailure trap indicates that IOT not responding during the ranging process.
Status: current Access: read-write
NOTIFICATION-TYPE    

qbDwsCompliances 1.3.6.1.4.1.4323.2.3.3.1
OBJECT IDENTIFIER    

qbDwsGroups 1.3.6.1.4.1.4323.2.3.3.2
OBJECT IDENTIFIER    

qbDwsCompliance 1.3.6.1.4.1.4323.2.3.3.1.1
The compliance statement for all agents that support this MIB. A compliant agent implements all objects defined in this MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

qbDwsNetGroupInfo 1.3.6.1.4.1.4323.2.3.3.2.1
The set of all accessible objects in the DWS Network Group of this MIB.
Status: current Access: read-write
OBJECT-GROUP    

qbDwsIotGroupInfo 1.3.6.1.4.1.4323.2.3.3.2.2
The set of all accessible objects in the IOT Group of this MIB.
Status: current Access: read-write
OBJECT-GROUP    

qbDwsPktGroupInfo 1.3.6.1.4.1.4323.2.3.3.2.3
The set of all accessible objects in the Packet Group ofthis MIB.
Status: current Access: read-write
OBJECT-GROUP    

qbDwsIotAddrGroupInfo 1.3.6.1.4.1.4323.2.3.3.2.4
The set of all accessible objects in the IOT address group of this MIB.
Status: current Access: read-write
OBJECT-GROUP