RAISECOM-PON-DEVICE-MIB

File: RAISECOM-PON-DEVICE-MIB.mib (50800 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SWITCH-TC
RAISECOM-PONSERIES-TC RAISECOM-BASE-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 IpAddress Unsigned32
DisplayString TimeStamp RowStatus
TruthValue MacAddress EnableVar
SlotIndex PONDeviceType PONDeviceCardType
raisecomAgent

Defined Types

RaisecomShelfEntry  
SEQUENCE    
  raisecomShelfId Integer32
  raisecomShelfDescr OCTET STRING Size(0..64)
  raisecomShelfSerialNum OCTET STRING Size(0..64)
  raisecomShelfHwVersion OCTET STRING Size(0..64)
  raisecomShelfLevel INTEGER
  raisecomShelfType OCTET STRING Size(0..64)
  raisecomShelfGenType INTEGER
  raisecomShelfMfrVendor OCTET STRING Size(0..64)
  raisecomShelfAssetID OCTET STRING Size(0..64)
  raisecomShelfTemperature INTEGER
  raisecomShelfSlotNum Integer32
  raisecomShelfNMSSlotNum INTEGER
  raisecomShelfPrimaryNMSSlotId Integer32
  raisecomShelfSecondaryNMSSlotId Integer32
  raisecomShelfMac MacAddress

RaisecomCardTemplateEntry  
SEQUENCE    
  raisecomCardType PONDeviceCardType
  raisecomCardPanelPortNum Integer32 0..16
  raisecomCardPanelPortTypes OCTET STRING Size(0..32)
  raisecomCardPermitedSlots INTEGER

RaisecomSlotEntry  
SEQUENCE    
  raisecomSlotId SlotIndex
  raisecomSlotDescr OCTET STRING Size(0..64)
  raisecomSlotExpectCardType PONDeviceCardType
  raisecomSlotExpectCardDescr OCTET STRING Size(0..64)
  raisecomSlotActCardType PONDeviceCardType
  raisecomSlotActCardDescr OCTET STRING Size(0..64)
  raisecomSlotActCardSerialNum OCTET STRING Size(0..64)
  raisecomSlotActCardHwVersion OCTET STRING Size(0..64)
  raisecomSlotActCardMfrVendor OCTET STRING Size(0..64)
  raisecomSlotActCardAssetID OCTET STRING Size(0..64)
  raisecomSlotActCardState INTEGER
  raisecomSlotReboot INTEGER
  raisecomSlotSupportCardTypes OCTET STRING Size(0..128)
  raisecomSlotActCardSwVersion OCTET STRING Size(0..64)
  raisecomSlotPowerState INTEGER

RaisecomPowerDeviceEntry  
SEQUENCE    
  raisecomPowerDeviceIndex SlotIndex
  raisecomPowerDeviceInputType INTEGER
  raisecomPowerInputvol Integer32
  raisecomPowerInputvolalarmState INTEGER
  raisecomPowerInputvolMinlowerVolThres Integer32
  raisecomPowerInputvolMinupperVolThres Integer32
  raisecomPowerInputvolMajlowerVolThres Integer32
  raisecomPowerInputvolMajupperVolThres Integer32
  raisecomPowerInputvolCrilowerVolThres Integer32
  raisecomPowerInputvolCriupperVolThres Integer32
  raisecomPowerTemperatureThres Integer32

RaisecomPowerOutputEntry  
SEQUENCE    
  raisecomPowerOutputType INTEGER
  raisecomPowerStatus INTEGER
  raisecomPowerOutputvol Integer32
  raisecomPowerOutputvollowerThres Integer32
  raisecomPowerOutputvolupperThres Integer32

RaisecomSubFanEntry  
SEQUENCE    
  raisecomFanSlotId SlotIndex
  raisecomSubFanId INTEGER
  raisecomSubFanStatus INTEGER
  raisecomSubFanSpeed INTEGER

RaisecomCardPowerEntry  
SEQUENCE    
  raisecomCardPowerSlotId SlotIndex
  raisecomCardPowerType INTEGER
  raisecomCardPowerVolValue Integer32
  raisecomCardPowerVolHighThres Integer32
  raisecomCardPowerVolLowThres Integer32

RaisecomAlarmInputEntry  
SEQUENCE    
  raisecomAlarmInputPortId Integer32
  raisecomAlarmInputType INTEGER
  raisecomAlarmInputDescr OCTET STRING Size(0..32)
  raisecomAlarmInputState INTEGER
  raisecomAlarmInputMontiorEnable INTEGER

Defined Values

raisecomdeviceMgt 1.3.6.1.4.1.8886.1.27
The MIB module defining objects for device management
MODULE-IDENTITY    

raisecomNEEquip 1.3.6.1.4.1.8886.1.27.1
OBJECT IDENTIFIER    

raisecomShelf 1.3.6.1.4.1.8886.1.27.2
OBJECT IDENTIFIER    

raisecomSlot 1.3.6.1.4.1.8886.1.27.3
OBJECT IDENTIFIER    

raisecomPower 1.3.6.1.4.1.8886.1.27.4
OBJECT IDENTIFIER    

raisecomFan 1.3.6.1.4.1.8886.1.27.5
OBJECT IDENTIFIER    

raisecomDeviceAlarm 1.3.6.1.4.1.8886.1.27.8
OBJECT IDENTIFIER    

raisecomAlarmInput 1.3.6.1.4.1.8886.1.27.10
OBJECT IDENTIFIER    

raisecomCardTemplate 1.3.6.1.4.1.8886.1.27.11
OBJECT IDENTIFIER    

raisecomCardPower 1.3.6.1.4.1.8886.1.27.12
OBJECT IDENTIFIER    

raisecomNEType 1.3.6.1.4.1.8886.1.27.1.1
Network element type.
Status: current Access: read-only
OBJECT-TYPE    
  PONDeviceType  

raisecomNEAssetID 1.3.6.1.4.1.8886.1.27.1.2
Asset ID of this network element for the carrier.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomNEMfrVendor 1.3.6.1.4.1.8886.1.27.1.3
Vendor name for this network element.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomNETmptAlarmThreshold 1.3.6.1.4.1.8886.1.27.1.4
Temperature threshold to issure the temperature alarm. The applicability depends on the device type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

raisecomShelfTable 1.3.6.1.4.1.8886.1.27.2.1
Shelf management table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RaisecomShelfEntry

raisecomShelfEntry 1.3.6.1.4.1.8886.1.27.2.1.1
Shelf management table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  RaisecomShelfEntry  

raisecomShelfId 1.3.6.1.4.1.8886.1.27.2.1.1.1
Shelf id.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..15  

raisecomShelfDescr 1.3.6.1.4.1.8886.1.27.2.1.1.2
Shelf description.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomShelfSerialNum 1.3.6.1.4.1.8886.1.27.2.1.1.3
Shelf device serial number.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomShelfHwVersion 1.3.6.1.4.1.8886.1.27.2.1.1.4
Shelf hardware version. For pizza-box type of device, it indicates version of the device, not of the card. For other type of device, it indicates version of the shelf, mainly of the backplane.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomShelfLevel 1.3.6.1.4.1.8886.1.27.2.1.1.5
Shelf level.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER masterShelf(1), extendShelf1(2), extendShelf2(3), extendShelf3(4), extendShelf4(5), extendShelf5(6), extendShelf6(7), extendShelf7(8), extendShelf8(9)  

raisecomShelfType 1.3.6.1.4.1.8886.1.27.2.1.1.6
Shelf type.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomShelfGenType 1.3.6.1.4.1.8886.1.27.2.1.1.7
Shelf Species.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), unknown(2), chassis(3), backplane(4), container(5), powerSupply(6), fan(7), sensor(8), module(9), port(10), stack(11)  

raisecomShelfMfrVendor 1.3.6.1.4.1.8886.1.27.2.1.1.8
Vendor name for this shelf.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomShelfAssetID 1.3.6.1.4.1.8886.1.27.2.1.1.9
Asset ID of this shelf.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomShelfTemperature 1.3.6.1.4.1.8886.1.27.2.1.1.10
Temperature of this shelf.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -100..100  

raisecomShelfSlotNum 1.3.6.1.4.1.8886.1.27.2.1.1.11
Number of slots for installing cards in this shelf.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..15  

raisecomShelfNMSSlotNum 1.3.6.1.4.1.8886.1.27.2.1.1.12
Number of slots for management and control cards in this shelf.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2  

raisecomShelfPrimaryNMSSlotId 1.3.6.1.4.1.8886.1.27.2.1.1.13
Slot for the primary management and control card.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..15  

raisecomShelfSecondaryNMSSlotId 1.3.6.1.4.1.8886.1.27.2.1.1.14
Slot for the secondary management and control card. Valid only when raisecomShelfNMSSlotNum equals to 2.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..15  

raisecomShelfMac 1.3.6.1.4.1.8886.1.27.2.1.1.15
The MAC address of this shelf.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

raisecomCardTemplateTable 1.3.6.1.4.1.8886.1.27.11.1
Card Template table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RaisecomCardTemplateEntry

raisecomCardTemplateEntry 1.3.6.1.4.1.8886.1.27.11.1.1
Card template table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  RaisecomCardTemplateEntry  

raisecomCardType 1.3.6.1.4.1.8886.1.27.11.1.1.1
The card type of this template.
Status: current Access: read-only
OBJECT-TYPE    
  PONDeviceCardType  

raisecomCardPanelPortNum 1.3.6.1.4.1.8886.1.27.11.1.1.2
Plane port number of this card-type template.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..16  

raisecomCardPanelPortTypes 1.3.6.1.4.1.8886.1.27.11.1.1.3
Plane port types of this type card template.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

raisecomCardPermitedSlots 1.3.6.1.4.1.8886.1.27.11.1.1.4
All the slot id of this type card which can be installed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

raisecomSlotTable 1.3.6.1.4.1.8886.1.27.3.1
Card slot management table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RaisecomSlotEntry

raisecomSlotEntry 1.3.6.1.4.1.8886.1.27.3.1.1
Card slot management table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  RaisecomSlotEntry  

raisecomSlotId 1.3.6.1.4.1.8886.1.27.3.1.1.1
Slot id.
Status: current Access: read-only
OBJECT-TYPE    
  SlotIndex  

raisecomSlotDescr 1.3.6.1.4.1.8886.1.27.3.1.1.2
Slot description.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomSlotExpectCardType 1.3.6.1.4.1.8886.1.27.3.1.1.3
Expected card type.
Status: current Access: read-write
OBJECT-TYPE    
  PONDeviceCardType  

raisecomSlotExpectCardDescr 1.3.6.1.4.1.8886.1.27.3.1.1.4
Description of the expected card. Currently unused.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomSlotActCardType 1.3.6.1.4.1.8886.1.27.3.1.1.5
Type of the card actually installed.
Status: current Access: read-only
OBJECT-TYPE    
  PONDeviceCardType  

raisecomSlotActCardDescr 1.3.6.1.4.1.8886.1.27.3.1.1.6
Description of the card actually installed. The applicability depends on the card type.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomSlotActCardSerialNum 1.3.6.1.4.1.8886.1.27.3.1.1.7
Serial number of the card actually installed.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomSlotActCardHwVersion 1.3.6.1.4.1.8886.1.27.3.1.1.8
Hardware version of the card actually installed.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomSlotActCardMfrVendor 1.3.6.1.4.1.8886.1.27.3.1.1.9
Vender name of the card actually installed.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomSlotActCardAssetID 1.3.6.1.4.1.8886.1.27.3.1.1.10
Asset id of the card actually installed.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomSlotActCardState 1.3.6.1.4.1.8886.1.27.3.1.1.11
Working state of the card actually installed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER lost(1), poweroffed(13), offline(2), type-identifying(11), nonprovision(3), typemismatched(4), generalfault(5), versionmismatched(6), initialized(12), configloading(7), configfailed(8), inservice(9), standby(10)  

raisecomSlotReboot 1.3.6.1.4.1.8886.1.27.3.1.1.12
Reboot the card. Result of reading this attribute is undefined.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cold(1), warm(2)  

raisecomSlotSupportCardTypes 1.3.6.1.4.1.8886.1.27.3.1.1.13
The slots on which the card type can be installed
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..128)  

raisecomSlotActCardSwVersion 1.3.6.1.4.1.8886.1.27.3.1.1.14
softerware version of the card actually installed.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

raisecomSlotPowerState 1.3.6.1.4.1.8886.1.27.3.1.1.15
set card power-save state on the slot.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

raisecomPowerDeviceTable 1.3.6.1.4.1.8886.1.27.4.1
Power device management table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RaisecomPowerDeviceEntry

raisecomPowerDeviceEntry 1.3.6.1.4.1.8886.1.27.4.1.1
Power device management table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  RaisecomPowerDeviceEntry  

raisecomPowerDeviceIndex 1.3.6.1.4.1.8886.1.27.4.1.1.1
Power device id.
Status: current Access: read-only
OBJECT-TYPE    
  SlotIndex  

raisecomPowerDeviceInputType 1.3.6.1.4.1.8886.1.27.4.1.1.2
Input type of this power device. Null value means that this power device is plugged out.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ac(2), dc48(3), dc24(4), dc12(5), null(6), ac220(7), ac110(8)  

raisecomPowerInputvol 1.3.6.1.4.1.8886.1.27.4.1.1.9
The input voltage of this power device, it is only meaningful for the manageable power.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -100..300  

raisecomPowerInputvolalarmState 1.3.6.1.4.1.8886.1.27.4.1.1.10
The input voltage alarm state of the power device, it is only meaningful for the manageable power.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), lowMin(2), lowMaj(3), lowCri(4), uppMin(5), uppMaj(6), uppCri(7)  

raisecomPowerInputvolMinlowerVolThres 1.3.6.1.4.1.8886.1.27.4.1.1.11
The input voltage lower threshold of the Minor alarm , it is only meaningful for the manageable power.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..300  

raisecomPowerInputvolMajlowerVolThres 1.3.6.1.4.1.8886.1.27.4.1.1.12
The input voltage lower threshold of the Major alarm, it is only meaningful for the manageable power .
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..300  

raisecomPowerInputvolCrilowerVolThres 1.3.6.1.4.1.8886.1.27.4.1.1.13
The input voltage lower threshold of the Critical alarm , it is only meaningful for the manageable power.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..300  

raisecomPowerInputvolMinupperVolThres 1.3.6.1.4.1.8886.1.27.4.1.1.14
The input voltage upper threshold of the Minor alarm , it is only meaningful for the manageable power.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..300  

raisecomPowerInputvolMajupperVolThres 1.3.6.1.4.1.8886.1.27.4.1.1.15
The input voltage upper threshold of the Major alarm , it is only meaningful for the manageable power.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..300  

raisecomPowerInputvolCriupperVolThres 1.3.6.1.4.1.8886.1.27.4.1.1.16
The input voltage upper threshold of the Critical alarm , it is only meaningful for the manageable power.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..300  

raisecomPowerTemperatureThres 1.3.6.1.4.1.8886.1.27.4.1.1.17
The temperature threshold of the power device , it is only meaningful for the manageable power, not used in V2.0.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..100  

raisecomPowerOutputTable 1.3.6.1.4.1.8886.1.27.4.2
Power device output management table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RaisecomPowerOutputEntry

raisecomPowerOutputEntry 1.3.6.1.4.1.8886.1.27.4.2.1
Power device output management table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  RaisecomPowerOutputEntry  

raisecomPowerOutputType 1.3.6.1.4.1.8886.1.27.4.2.1.1
Output type of the power device.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rcPowerOther(1), rcPower3v(2), rcPower5v(3), rcPower12v(4), rcPower-48v(5)  

raisecomPowerStatus 1.3.6.1.4.1.8886.1.27.4.2.1.2
Output status of this power output. Null value means that this output port does not exist.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), null(3), highAlarm(4), lowAlarm(5)  

raisecomPowerOutputvol 1.3.6.1.4.1.8886.1.27.4.2.1.3
Output voltage of the power,it is only meaningful for the manageable power, for the 5v output voltage ,the unit is 0.01v; for the -48V output voltage, the unit is 0.1v
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1000..1000  

raisecomPowerOutputvollowerThres 1.3.6.1.4.1.8886.1.27.4.2.1.4
The threshold of the low output voltage alarm,it is only meaningful for the manageable power, for the 5v output voltage ,the unit is 0.01v; for the -48V output voltage, the unit is 0.1v
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -500..500  

raisecomPowerOutputvolupperThres 1.3.6.1.4.1.8886.1.27.4.2.1.5
The threshold of the high output voltage alarm,it is only meaningful for the manageable power, for the 5v output voltage ,the unit is 0.01v; for the -48V output voltage, the unit is 0.1v
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -600..600  

raisecomSubFanTable 1.3.6.1.4.1.8886.1.27.5.1
Fan management table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RaisecomSubFanEntry

raisecomSubFanEntry 1.3.6.1.4.1.8886.1.27.5.1.1
Fan management table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  RaisecomSubFanEntry  

raisecomFanSlotId 1.3.6.1.4.1.8886.1.27.5.1.1.1
Slot Index.
Status: current Access: read-only
OBJECT-TYPE    
  SlotIndex  

raisecomSubFanId 1.3.6.1.4.1.8886.1.27.5.1.1.2
Sub Fan Index.
Status: current Access: read-only
OBJECT-TYPE    
  SlotIndex  

raisecomSubFanStatus 1.3.6.1.4.1.8886.1.27.5.1.1.3
Fan status. Null value means that this fan is plugged out.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), null(3), unknown(4)  

raisecomSubFanSpeed 1.3.6.1.4.1.8886.1.27.5.1.1.4
Fan current speed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

raisecomFanMaxSpeed 1.3.6.1.4.1.8886.1.27.5.2
the maximum fan speed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

raisecomFanMinSpeed 1.3.6.1.4.1.8886.1.27.5.3
the minimun fan speed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

raisecomFanSpeedMode 1.3.6.1.4.1.8886.1.27.5.4
the fan control mode ,auto means the fan speed is controled by the temperature automatically,the other means controled manually.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), manual(2)  

raisecomFanSpeedManual 1.3.6.1.4.1.8886.1.27.5.5
manual control the fan speed by configurating the fan different gear.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..40  

raisecomFanSpeedGear 1.3.6.1.4.1.8886.1.27.5.6
the fan speed gear.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..8  

raisecomCardPowerTable 1.3.6.1.4.1.8886.1.27.12.1
Card power management table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RaisecomCardPowerEntry

raisecomCardPowerEntry 1.3.6.1.4.1.8886.1.27.12.1.1
card power management table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  RaisecomCardPowerEntry  

raisecomCardPowerSlotId 1.3.6.1.4.1.8886.1.27.12.1.1.1
Slot Index.
Status: current Access: read-only
OBJECT-TYPE    
  SlotIndex  

raisecomCardPowerType 1.3.6.1.4.1.8886.1.27.12.1.1.2
card power types.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER power075v(1), power09v(2), power1v(3), power12v(4), power15v(5), power18v(6), power25v(7), power33v(8), power48v(9), power5v(10), power52v(11), power120v(12), unknown(13), null(14), power125v(15), power29v(16)  

raisecomCardPowerVolValue 1.3.6.1.4.1.8886.1.27.12.1.1.3
the current card voltage of the power type.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

raisecomCardPowerVolHighThres 1.3.6.1.4.1.8886.1.27.12.1.1.4
the high voltage threshold of the power.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

raisecomCardPowerVolLowThres 1.3.6.1.4.1.8886.1.27.12.1.1.5
the low voltage threshold of the power.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

raisecomAlarmInputTable 1.3.6.1.4.1.8886.1.27.10.1
Alarm input management table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RaisecomAlarmInputEntry

raisecomAlarmInputEntry 1.3.6.1.4.1.8886.1.27.10.1.1
Alarm input management table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  RaisecomAlarmInputEntry  

raisecomAlarmInputPortId 1.3.6.1.4.1.8886.1.27.10.1.1.1
Alarm Input port id.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

raisecomAlarmInputType 1.3.6.1.4.1.8886.1.27.10.1.1.2
Alarm type code. 0 means that this port is unused.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

raisecomAlarmInputDescr 1.3.6.1.4.1.8886.1.27.10.1.1.3
Alarm type description.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

raisecomAlarmInputState 1.3.6.1.4.1.8886.1.27.10.1.1.4
State of this input port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), null(3), missing(4), unknown(5)  

raisecomAlarmInputMontiorEnable 1.3.6.1.4.1.8886.1.27.10.1.1.5
enable or disable the function of the port environment monitor , default is disable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

raisecomPowerMissTrap 1.3.6.1.4.1.8886.1.27.8.1
Power device missing notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomPowerFoundTrap 1.3.6.1.4.1.8886.1.27.8.2
Power device plugged-in notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomPowerFaultTrap 1.3.6.1.4.1.8886.1.27.8.3
Power device abnormal notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomPowerFaultRecoveredTrap 1.3.6.1.4.1.8886.1.27.8.4
Power device fault recovered notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomFanMissTrap 1.3.6.1.4.1.8886.1.27.8.5
Fan missing notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomFanFoundTrap 1.3.6.1.4.1.8886.1.27.8.6
Fan plugged-in notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomSubFanFaultTrap 1.3.6.1.4.1.8886.1.27.8.7
Sub Fan abnormal notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomSubFanFaultRecoveredTrap 1.3.6.1.4.1.8886.1.27.8.8
Sub Fan fault recovered notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomCardMissTrap 1.3.6.1.4.1.8886.1.27.8.9
Card missing notification. Sent when no card is detected in a slot and expected card type for this slot is configured. It will not be sent for power devices and fans.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomCardMissCancelledTrap 1.3.6.1.4.1.8886.1.27.8.10
Card plugged-in notification. It will not be sent for power devices and fans.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomNonInstalledCardExist 1.3.6.1.4.1.8886.1.27.8.11
Non-installed card plugged-in notification. The binded variable 'raisecomSlotActCardType' is currently unused. It will not be sent for power devices and fans.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomNonInstalledCardExistCancelled 1.3.6.1.4.1.8886.1.27.8.12
Non-installed card plugged-out or installed notification. It will not be sent for power devices and fans.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomCardTypeMisMatchTrap 1.3.6.1.4.1.8886.1.27.8.13
Actual card type and expected card type mismatched notification. It will not be sent for power devices and fans.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomCardTypeMisMatchCancelledTrap 1.3.6.1.4.1.8886.1.27.8.14
Actual card type and expected card type matched notification. It will not be sent for power devices and fans.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomCardFaultTrap 1.3.6.1.4.1.8886.1.27.8.15
Card abnormal notification. It will not be sent for power devices and fans.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomCardFaultRecoveredTrap 1.3.6.1.4.1.8886.1.27.8.16
Card fault recovered notificaiton. It will not be sent for power devices and fans.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomShelfTempertureThresholdCrossingTrap 1.3.6.1.4.1.8886.1.27.8.17
Shelf temperature threshold crossing notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomShelfTempertureRecoveredTrap 1.3.6.1.4.1.8886.1.27.8.18
Shelf temperature recovered notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomNonInstalledCardTypeTrap 1.3.6.1.4.1.8886.1.27.8.19
Card type of a non-installed card notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomCardPowerFaultTrap 1.3.6.1.4.1.8886.1.27.8.20
Card power fault notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomCardPowerFaultRecoveredTrap 1.3.6.1.4.1.8886.1.27.8.21
Card power fault recovered notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomExternalAlarmTrap 1.3.6.1.4.1.8886.1.27.8.22
External alarm notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomExternalAlarmRecoverdTrap 1.3.6.1.4.1.8886.1.27.8.23
External alarm recovered notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomSubFanAgingTrap 1.3.6.1.4.1.8886.1.27.8.24
Sub Fan aging notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomSubFanAgingRecoveredTrap 1.3.6.1.4.1.8886.1.27.8.25
Sub Fan aging recovered notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomPowerVoltageInputTrap 1.3.6.1.4.1.8886.1.27.8.28
Input voltage abnormal notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomPowerVoltageInputRecoveredTrap 1.3.6.1.4.1.8886.1.27.8.29
Input voltage abnormal recovered notification, it is only meaningful for the manageable power.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomPowerVoltageOutputTrap 1.3.6.1.4.1.8886.1.27.8.30
output voltage abnormal notification, it is only meaningful for the manageable power.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomPowerVoltageOutputRecoveredTrap 1.3.6.1.4.1.8886.1.27.8.31
output voltage abnormal recovered notification, it is only meaningful for the manageable power.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomPowerTemperatureTooHighTrap 1.3.6.1.4.1.8886.1.27.8.32
power temperature too high notification, it is only meaningful for the manageable power.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomPowerTemperatureTooHighRecoveredTrap 1.3.6.1.4.1.8886.1.27.8.33
power temperature too high recovered notification, it is only meaningful for the manageable power.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomCardLoadConfigFailedTrap 1.3.6.1.4.1.8886.1.27.8.34
Card config loading failed notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomCardVersionMismatchTrap 1.3.6.1.4.1.8886.1.27.8.35
Card version mismatched notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

raisecomCardVersionMismatchRecoveredTrap 1.3.6.1.4.1.8886.1.27.8.36
Card version-mismatch recovered notification.
Status: current Access: read-write
NOTIFICATION-TYPE