REDLINE-AN80I-IF-MIB

File: REDLINE-AN80I-IF-MIB.mib (31814 bytes)

Imported modules

REDLINE-MIB SNMPv2-SMI SNMPv2-CONF
SNMPv2-TC

Imported symbols

redlineTransmission MODULE-IDENTITY OBJECT-TYPE
NOTIFICATION-TYPE Unsigned32 Counter32
Integer32 Counter64 TimeTicks
OBJECT-GROUP NOTIFICATION-GROUP MODULE-COMPLIANCE
DisplayString MacAddress RowStatus

Defined Types

An80iIfPmpLinkConfigEntry  
SEQUENCE    
  an80iIfPmpLinkId INTEGER
  an80iIfPmpLinkName DisplayString
  an80iIfPmpLinkPeerMacAddress MacAddress
  an80iIfPmpLinkULBurstRate Unsigned32
  an80iIfPmpLinkDLBurstRate Unsigned32
  an80iIfPmpLinkConfigStatus RowStatus

An80iIfPmpLinkStatsEntry  
SEQUENCE    
  an80iIfPmpLinkStatus INTEGER
  an80iIfPmpLinkStatusCode Integer32
  an80iIfRegPmpLinkConns Integer32
  an80iIfPmpLinkLostCount Counter32
  an80iIfPmpLinkUpTime TimeTicks
  an80iIfPmpLinkCurrDLUncBurstRate Unsigned32
  an80iIfPmpLinkDLRssi Integer32
  an80iIfPmpLinkDLSinAdr Integer32
  an80iIfPmpLinkDLLostFrm Counter64
  an80iIfPmpLinkDLBlksTot Counter64
  an80iIfPmpLinkDLBlksRetr Counter64
  an80iIfPmpLinkDLBlksDisc Counter64
  an80iIfPmpLinkCurrULUncBurstRate Unsigned32
  an80iIfPmpLinkULRssi Integer32
  an80iIfPmpLinkULSinAdr Integer32
  an80iIfPmpLinkULLostFrm Counter64
  an80iIfPmpLinkULBlksTot Counter64
  an80iIfPmpLinkULBlksRetr Counter64
  an80iIfPmpLinkULBlksDisc Counter64
  an80iIfPmpLinkStatsStatus RowStatus

An80iIfPmpGroupConfigEntry  
SEQUENCE    
  an80iIfPmpGroupId INTEGER
  an80iIfPmpGroupName DisplayString
  an80iIfPmpGroupTaggingControl INTEGER
  an80iIfPmpGroupVlanId INTEGER
  an80iIfPmpGroupDefPriority INTEGER
  an80iIfPmpGroupSCEtherControl INTEGER
  an80iIfPmpGroupQosLevel INTEGER
  an80iIfPmpGroupRate INTEGER
  an80iIfPmpGroupSStoSSMulticast INTEGER
  an80iIfPmpGroupConfigStatus RowStatus

An80iIfPmpGroupStatsEntry  
SEQUENCE    
  an80iIfPmpGroupPacketsTx Counter64
  an80iIfPmpGroupPacketDisc Counter64
  an80iIfPmpGroupStatsStatus RowStatus

An80iIfPmpConnConfigEntry  
SEQUENCE    
  an80iIfPmpConnId INTEGER
  an80iIfPmpConnName DisplayString
  an80iIfPmpConnTaggingControl INTEGER
  an80iIfPmpConnVlanId INTEGER
  an80iIfPmpConnDefPriority INTEGER
  an80iIfPmpConnDefParentLink INTEGER
  an80iIfPmpConnDefParenGroup INTEGER
  an80iIfPmpConnDLQos INTEGER
  an80iIfPmpConnULQos INTEGER
  an80iIfPmpConnConfigStatus RowStatus

An80iIfPmpConnStatsEntry  
SEQUENCE    
  an80iIfPmpConnDLPacketsTx Counter64
  an80iIfPmpConnDLPacketsRx Counter64
  an80iIfPmpConnDLPacketsDisc Counter64
  an80iIfPmpConnULPacketsTx Counter64
  an80iIfPmpConnULPacketsRx Counter64
  an80iIfPmpConnULPacketsDisc Counter64
  an80iIfPmpConnStatsStatus RowStatus

Defined Values

redlineAn80iIfMib 2.2.10.2
This MIB module contains object definitions applicable only to Redline AN80i module.
MODULE-IDENTITY    

redlineAn80iIfPtpObjects 2.2.10.2.1
OBJECT IDENTIFIER    

redlineAn80iIfPtpLinkConfig 2.2.10.2.1.1
OBJECT IDENTIFIER    

an80iIfEncryptionControl 2.2.10.2.1.1.1
Specifies if encryption type.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), redline(2), aes128(3), aes192(4), aes256(5)  

an80iIfModReduction 2.2.10.2.1.1.2
Applies when the adaptive rate is disabled, and specifies how many levels the system must drop in modulation before beginning retransmission to address packet errors.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

an80iIfAdaptiveMod 2.2.10.2.1.1.3
If enabled, the system automatically adjust the modulation to obtain the maximum throughput.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

an80iIfUncodedBurstRate 2.2.10.2.1.1.4
The maximum index of the link uncoded burst rate. The rate also depends on the channel width. The possible values are 0..7.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

an80iIfEncryptionKey 2.2.10.2.1.1.5
The Encryption Key used for the AN-80i. Enter the MAC address of the peer equipment to enable over-the-air data encryption.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING  

an80iIfPacketRetransControl 2.2.10.2.1.1.6
Enables/disables packet retransmission. The retransmission scheme is based on the Acknowledge /Request (ARQ) algorithm that detects when packets are lost and makes a request to the MAC scheduler to repeat transmission of the lost packets.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

an80iIfLinkLenMode 2.2.10.2.1.1.7
In manual mode the system uses the user-supplied value for link length. In the auto mode the system calculate itself the distance, which can be read using 'calculated distance'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), manual(2)  

an80iIfLinkLength 2.2.10.2.1.1.8
User supplied PTP Link Length [Km].
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

an80iIfCalcLinkDst 2.2.10.2.1.1.9
The calculated link distance [Km].
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iIfLinkName 2.2.10.2.1.1.10
Link Name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..31)  

redlineAn80iIfPtpLinkStats 2.2.10.2.1.2
OBJECT IDENTIFIER    

an80iIfCurrUncodedBurstRate 2.2.10.2.1.2.1
Indicates the index of the link uncoded burst rate. With adaptive modulation enabled, this rate may change over time.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

an80iIfPtpLinkStatus 2.2.10.2.1.2.2
Indicates if the link has been established/not established.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

an80iIfRxPackets 2.2.10.2.1.2.3
Indicates the number of received wireless packets with a correct CRC.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfRxPacketsReTx 2.2.10.2.1.2.4
Indicates the number of received retransmitted wireless packets with a correct CRC.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfRxPacketsDisc 2.2.10.2.1.2.5
Indicates the number of received retransmitted wireless packets with bad CRC.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfTxPackets 2.2.10.2.1.2.6
Indicates the number of transmitted packets that were received correctly by the other equipment.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfTxPacketsReTx 2.2.10.2.1.2.7
Indicates the number of retransmitted wireless packets received correctly by the other equipment.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfTxPacketsDisc 2.2.10.2.1.2.8
Indicates the number of retransmitted wireless packets that were not received correctly by the other equipment
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfRssiMin 2.2.10.2.1.2.9
Indicates the minimum received signal strength for the measuring interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iIfRssiMean 2.2.10.2.1.2.10
Indicates the average received signal strength for the measuring interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iIfRssiMax 2.2.10.2.1.2.11
Indicates the maximum received signal strength for the measuring interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iIfAvrSinAdr 2.2.10.2.1.2.12
Indicates the Signal to interference, noise and distortion ratio.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

redlineAn80iIfPmpObjects 2.2.10.2.2
OBJECT IDENTIFIER    

redlineAn80iIfPmpSsObjects 2.2.10.2.2.1
OBJECT IDENTIFIER    

an80iIfLastMissedMacAddress 2.2.10.2.2.1.1
MAC address for the last SS that attempted to register but it was not present in the 'Links' table
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

an80iIfLastRegistMacAddress 2.2.10.2.2.1.2
MAC address for the last SS that successfuly registered
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

an80iIfDenyMacAddress 2.2.10.2.2.1.3
MAC address for the SS that will be denied by this SC
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

an80iIfLastRegistLinkId 2.2.10.2.2.1.4
The link ID for the last SS that successfully registered
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1023  

an80iIfPmpLinkConfigTable 2.2.10.2.2.2
This table contains the PMP link configuration information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    An80iIfPmpLinkConfigEntry

an80iIfPmpLinkConfigEntry 2.2.10.2.2.2.1
This table provides one row for each PMP link that has been configured in the SC.
Status: current Access: not-accessible
OBJECT-TYPE    
  An80iIfPmpLinkConfigEntry  

an80iIfPmpLinkId 2.2.10.2.2.2.1.1
The PMP Link Identifier.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 4..1023  

an80iIfPmpLinkName 2.2.10.2.2.2.1.2
The PMP Link Name.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..15)  

an80iIfPmpLinkPeerMacAddress 2.2.10.2.2.2.1.3
The MAC address for the peer SS
Status: current Access: read-create
OBJECT-TYPE    
  MacAddress  

an80iIfPmpLinkULBurstRate 2.2.10.2.2.2.1.4
User supplied index of the uplink uncoded burst rate.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

an80iIfPmpLinkDLBurstRate 2.2.10.2.2.2.1.5
User supplied index of the downlink uncoded burst rate.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

an80iIfPmpLinkConfigStatus 2.2.10.2.2.2.1.6
This object is used to create a new row or modify or delete an existing row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

an80iIfPmpLinkStatsTable 2.2.10.2.2.3
This table contains the PMP link statistics information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    An80iIfPmpLinkStatsEntry

an80iIfPmpLinkStatsEntry 2.2.10.2.2.3.1
This table provides one row for each PMP link that has been configured in the Service Controller.
Status: current Access: not-accessible
OBJECT-TYPE    
  An80iIfPmpLinkStatsEntry  

an80iIfPmpLinkStatus 2.2.10.2.2.3.1.1
Indicates if the link has been established/not established.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

an80iIfPmpLinkStatusCode 2.2.10.2.2.3.1.2
Indicates the error code for the link.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iIfRegPmpLinkConns 2.2.10.2.2.3.1.3
Indicates the registered connections for this Link.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iIfPmpLinkUpTime 2.2.10.2.2.3.1.4
The time (in hundredths of a second) elapsed since the link was established (up) last time.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

an80iIfPmpLinkLostCount 2.2.10.2.2.3.1.5
Number of times the link has been lost since the system started.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

an80iIfPmpLinkCurrDLUncBurstRate 2.2.10.2.2.3.1.6
Indicates the index of the link's downlink actual uncoded burst rate.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

an80iIfPmpLinkDLRssi 2.2.10.2.2.3.1.7
Indicates the link's DL RSSI (Received Signal Strength Indicator).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iIfPmpLinkDLSinAdr 2.2.10.2.2.3.1.8
Indicates the link's DL SINADR (Signal Interference and Noise Distorsion Ratio).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iIfPmpLinkDLLostFrm 2.2.10.2.2.3.1.9
Indicates the link's DL lost frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpLinkDLBlksTot 2.2.10.2.2.3.1.10
Indicates the link's DL blocks transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpLinkDLBlksRetr 2.2.10.2.2.3.1.11
Indicates the link's DL block re-transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpLinkDLBlksDisc 2.2.10.2.2.3.1.12
Indicates the link's DL blocks lost
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpLinkCurrULUncBurstRate 2.2.10.2.2.3.1.13
Indicates the index of the link's uplink actual uncoded burst rate.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

an80iIfPmpLinkULRssi 2.2.10.2.2.3.1.14
Indicates the link's UL RSSI (Received Signal Strength Indicator).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iIfPmpLinkULSinAdr 2.2.10.2.2.3.1.15
Indicates the link's UL SINADR (Signal Interference and Noise Distorsion Ratio).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iIfPmpLinkULLostFrm 2.2.10.2.2.3.1.16
Indicates the link's UL lost frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpLinkULBlksTot 2.2.10.2.2.3.1.17
Indicates the link's UL blocks transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpLinkULBlksRetr 2.2.10.2.2.3.1.18
Indicates the link's UL block re-transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpLinkULBlksDisc 2.2.10.2.2.3.1.19
Indicates the link's UL blocks lost
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpLinkStatsStatus 2.2.10.2.2.3.1.20
This object is used to create a new row or modify or delete an existing row in this table.
Status: current Access: read-only
OBJECT-TYPE    
  RowStatus  

an80iIfPmpGroupConfigTable 2.2.10.2.2.4
This table contains group configuration information. The group defined as a broadcast domain.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    An80iIfPmpGroupConfigEntry

an80iIfPmpGroupConfigEntry 2.2.10.2.2.4.1
This table provides one row for each group defined in the Service Controller
Status: current Access: not-accessible
OBJECT-TYPE    
  An80iIfPmpGroupConfigEntry  

an80iIfPmpGroupId 2.2.10.2.2.4.1.1
The PMP Group Identifier.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 4..1023  

an80iIfPmpGroupName 2.2.10.2.2.4.1.2
The PMP Group Name.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..15)  

an80iIfPmpGroupTaggingControl 2.2.10.2.2.4.1.3
Specifies tagging mode.Only one pass-through group can exist. This is the default group. In the pass-through mode all the Ethernet packets that do not have a VLAN tag or an undefined VID will be classified in this group.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER passThrough(1), tagged(2)  

an80iIfPmpGroupVlanId 2.2.10.2.2.4.1.4
In the tagged mode all Ethernet packets that have this VID will be classified to belong to this group.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..4095  

an80iIfPmpGroupDefPriority 2.2.10.2.2.4.1.5
This field is used every time a tag is added at the exit point. The priority will be the one specified at the entry point.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..7  

an80iIfPmpGroupSCEtherControl 2.2.10.2.2.4.1.6
Makes the Sector Controller a member of the group.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

an80iIfPmpGroupQosLevel 2.2.10.2.2.4.1.7
QoS level (index) that will affect the bandwidth and the delay for this group.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..53  

an80iIfPmpGroupConfigStatus 2.2.10.2.2.4.1.8
This object is used to create a new row or modify or delete an existing row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

an80iIfPmpGroupRate 2.2.10.2.2.4.1.9
Define the index of the group rate. (0..7, 8=auto)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..8  

an80iIfPmpGroupSStoSSMulticast 2.2.10.2.2.4.1.10
Enable the Subscriber to subscriber multicast traffic.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

an80iIfPmpGroupStatsTable 2.2.10.2.2.5
This table contains group statistics information. The group defined as a broadcast domain.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    An80iIfPmpGroupStatsEntry

an80iIfPmpGroupStatsEntry 2.2.10.2.2.5.1
This table provides one row for each group defined in the Service Controller
Status: current Access: not-accessible
OBJECT-TYPE    
  An80iIfPmpGroupStatsEntry  

an80iIfPmpGroupPacketsTx 2.2.10.2.2.5.1.1
Broadcast/multicast Ethernet packets classified and transmitted to the group.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpGroupPacketDisc 2.2.10.2.2.5.1.2
Ethernet packets classified to be sent to the group but discarded due to unavailable memory.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpGroupStatsStatus 2.2.10.2.2.5.1.3
This object is used to create a new row or modify or delete an existing row in this table.
Status: current Access: read-only
OBJECT-TYPE    
  RowStatus  

an80iIfPmpConnConfigTable 2.2.10.2.2.6
This table contains connections configuration information. One connection defines the transport parameter for Ethernet packets that have specific properties.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    An80iIfPmpConnConfigEntry

an80iIfPmpConnConfigEntry 2.2.10.2.2.6.1
This table provides one row for each connection defined in the Service Controller
Status: current Access: not-accessible
OBJECT-TYPE    
  An80iIfPmpConnConfigEntry  

an80iIfPmpConnId 2.2.10.2.2.6.1.1
The PMP Conn Identifier.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 4..1023  

an80iIfPmpConnName 2.2.10.2.2.6.1.2
The PMP Conn Name.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..15)  

an80iIfPmpConnTaggingControl 2.2.10.2.2.6.1.3
Specifies tagging mode. Only one pass-through connection can be defined on each link. This is the default connection. All the untagged packets or with a VID that is not defined will be transmitted on this connection.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER passThrough(1), tagged(2)  

an80iIfPmpConnVlanId 2.2.10.2.2.6.1.4
Specifies VLAN Id for the tagged mode.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..4095  

an80iIfPmpConnDefPriority 2.2.10.2.2.6.1.5
This field is used every time a tag is added at the exit point. The priority will be the one specified at the entry point.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..7  


an80iIfPmpConnDefParenGroup 2.2.10.2.2.6.1.7
This object specifies the parent group of the connection.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 4..1023  

an80iIfPmpConnDLQos 2.2.10.2.2.6.1.8
Connection QoS level (index) that will affect the DL bandwidth and the delay.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..53  

an80iIfPmpConnULQos 2.2.10.2.2.6.1.9
Connection QoS level (index) that will affect the UL bandwidth and the delay.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..53  

an80iIfPmpConnConfigStatus 2.2.10.2.2.6.1.10
This object is used to create a new row or modify or delete an existing row in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

an80iIfPmpConnStatsTable 2.2.10.2.2.7
This table contains connections configuration information. One connection defines the transport parameter for Ethernet packets that have specific properties.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    An80iIfPmpConnStatsEntry

an80iIfPmpConnStatsEntry 2.2.10.2.2.7.1
This table provides one row for each connection defined in the Service Controller
Status: current Access: not-accessible
OBJECT-TYPE    
  An80iIfPmpConnStatsEntry  

an80iIfPmpConnDLPacketsTx 2.2.10.2.2.7.1.1
Indicates Ethernet packets sent by SC.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpConnDLPacketsRx 2.2.10.2.2.7.1.2
Indicates Ethernet packets receivedby SS.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpConnDLPacketsDisc 2.2.10.2.2.7.1.3
Indicates packets discarded due to full buffer.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpConnULPacketsTx 2.2.10.2.2.7.1.4
Indicates Ethernet packets sent by SS.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpConnULPacketsRx 2.2.10.2.2.7.1.5
Indicates Ethernet packets received SC.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpConnULPacketsDisc 2.2.10.2.2.7.1.6
Indicates packets discarded due to full buffer.
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

an80iIfPmpConnStatsStatus 2.2.10.2.2.7.1.7
This object is used to create a new row or modify or delete an existing row in this table.
Status: current Access: read-only
OBJECT-TYPE    
  RowStatus  

redlineAn80iIfTrapDefinitions 2.2.10.2.0
OBJECT IDENTIFIER    

an80iIfRegistrationFailedTrap 2.2.10.2.0.1
Event that reports the failure of a registration attempt of a SS that is not defined in the link table.
Status: current Access: read-only
NOTIFICATION-TYPE    

an80iIfRegistrationOKTrap 2.2.10.2.0.2
An event to report the successful SS registration.
Status: current Access: read-only
NOTIFICATION-TYPE    

redlineAn80iIfConformance 2.2.10.2.4
OBJECT IDENTIFIER    

redlineAn80iIfGroups 2.2.10.2.4.1
OBJECT IDENTIFIER    

redlineAn80iIfCompls 2.2.10.2.4.2
OBJECT IDENTIFIER    

redlineAn80iIfPtpGroup 2.2.10.2.4.1.1
Point to point link objects.
Status: current Access: read-only
OBJECT-GROUP    

redlineAn80iIfPmpGroup 2.2.10.2.4.1.2
Point to multipoint link objects.
Status: current Access: read-only
OBJECT-GROUP    

redlineAn80iIfNotificationGroup 2.2.10.2.4.1.3
The notifications which indicate specific events within the AN80i interface.
Status: current Access: read-only
NOTIFICATION-GROUP    

redlineAn80iIfCompliance 2.2.10.2.4.2.1
The compliance statement for SNMP entities that implement this MIB module.
Status: current Access: read-only
MODULE-COMPLIANCE