REDLINE-AN80I-MIB

File: REDLINE-AN80I-MIB.mib (19095 bytes)

Imported modules

REDLINE-MIB SNMPv2-SMI SNMPv2-CONF
SNMPv2-TC INET-ADDRESS-MIB

Imported symbols

redlineSystem MODULE-IDENTITY OBJECT-TYPE
NOTIFICATION-TYPE TimeTicks Integer32
OBJECT-GROUP MODULE-COMPLIANCE NOTIFICATION-GROUP
DisplayString RowStatus InetAddress
InetAddressType InetPortNumber

Defined Types

An80iOptionsKeyEntry  
SEQUENCE    
  an80iOptionsKeyId INTEGER
  an80iOptionsKey DisplayString
  an80iOptionsKeyStatus RowStatus

Defined Values

redlineAn80iMib 1.3.6.1.4.1.10728.2.1.3
This MIB module contains object definitions applicable only to Redline AN80i switched device.
MODULE-IDENTITY    

redlineAn80iPtpPmpObjects 1.3.6.1.4.1.10728.2.1.3.1
OBJECT IDENTIFIER    

redlineAn80iSystemObjects 1.3.6.1.4.1.10728.2.1.3.1.1
OBJECT IDENTIFIER    

an80iOptionsKeyTable 1.3.6.1.4.1.10728.2.1.3.1.1.1
This table contains options key information. The maximum number of configured options key is 2.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    An80iOptionsKeyEntry

an80iOptionsKeyEntry 1.3.6.1.4.1.10728.2.1.3.1.1.1.1
This table provides one row for each option key defined in the AN80i system
Status: current Access: not-accessible
OBJECT-TYPE    
  An80iOptionsKeyEntry  

an80iOptionsKeyId 1.3.6.1.4.1.10728.2.1.3.1.1.1.1.1
The Options Key Identifier.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..2  

an80iOptionsKey 1.3.6.1.4.1.10728.2.1.3.1.1.1.1.2
The options key value.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

an80iOptionsKeyStatus 1.3.6.1.4.1.10728.2.1.3.1.1.1.1.3
This object is used to ctivate and deactivate rows in the an80iOptionsKeyTable table. There will be only two rows in the table and only one will be active. When one row is active the other one will be notInService. The row can not be created or deleted
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

an80iHardwareType 1.3.6.1.4.1.10728.2.1.3.1.1.2
The type/version/revision of the hardware.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iRadioType 1.3.6.1.4.1.10728.2.1.3.1.1.3
The radio type.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iSaveConfig 1.3.6.1.4.1.10728.2.1.3.1.1.4
This object will save the configuration in the nonvolatile memory and will activate the new configuration.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noop(1), saveConfig(2)  

an80iActivateConfig 1.3.6.1.4.1.10728.2.1.3.1.1.5
This object will activate the new configuration without saving it in the nonvolatile memory. If after this event it will elapse more than 5 minutes and no save configuration occurs, then system will restart with the configuration from the nonvolatile memory.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noop(1), activeConfig(2)  

redlineAn80iWirelesObjects 1.3.6.1.4.1.10728.2.1.3.1.2
OBJECT IDENTIFIER    

an80iAntennaAllignmentMode 1.3.6.1.4.1.10728.2.1.3.1.2.1
Specifies if the antenna alignment buzzer is enabled or not. In the future, new alignment methods may be added.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), buzzer(2)  

an80iCurrTxPower 1.3.6.1.4.1.10728.2.1.3.1.2.2
The actual Tx Power of the AN-80i Node.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -10..20  

an80iChannelAutoScan 1.3.6.1.4.1.10728.2.1.3.1.2.3
Specifies if the frequency auto-scanning feature is enabled
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

an80iCurrFrequency 1.3.6.1.4.1.10728.2.1.3.1.2.4
The central frequency on which the equipment operates. If the auto-scanning feature is enabled then this may be different than the an80iOPeratingFrequency. [KHz]
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iOPeratingFrequency 1.3.6.1.4.1.10728.2.1.3.1.2.5
Specifies the operating frequency of the system [KHz].
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

an80iMaxTxPower 1.3.6.1.4.1.10728.2.1.3.1.2.6
The Tx Power of the AN-80i. Specifies the power level of the system, which is preset at the factory and should not be altered. In the event that this parameter needs to be changed, please contact the Redline support team.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER -10..20  

an80iSystemMode 1.3.6.1.4.1.10728.2.1.3.1.2.7
1 = PMP Slave, 2 = PTP Master, 3 = PMP Slave, 4 = PMP Master
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ptpSlave(1), ptpMaster(2), pmpSlave(3), pmpMaster(4)  

an80iRFStatusCode 1.3.6.1.4.1.10728.2.1.3.1.2.8
Specifies the Error Code for the RF Interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iDFSAction 1.3.6.1.4.1.10728.2.1.3.1.2.9
Action taken when a radar is detected on the same frequency.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), txDisabled(2), changeFreq(3)  

an80iAntennaGain 1.3.6.1.4.1.10728.2.1.3.1.2.10
The gain of the antenna attached to the system.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  


an80iAtpControl 1.3.6.1.4.1.10728.2.1.3.1.2.12
Enable/disable the automatic Tx power control.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

an80iTurboModeControl 1.3.6.1.4.1.10728.2.1.3.1.2.13
Enable/disable the turbo mode. In this mode the system uses a 40MHz channel (20 MHz in normal mode).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

an80iChannelWidth 1.3.6.1.4.1.10728.2.1.3.1.2.14
The width of the channel.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER chWidth40MHz(7), chWidth20MHz(6), chWidth10MHz(5)  

redlineAn80iEthernetObjects 1.3.6.1.4.1.10728.2.1.3.1.3
OBJECT IDENTIFIER    

an80iEtherPortConn 1.3.6.1.4.1.10728.2.1.3.1.3.1
Specifies Ethernet port connection auto(1), mdi(2) or mdix(3)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), normal(2), crossover(3)  

an80iEtherPortMode 1.3.6.1.4.1.10728.2.1.3.1.3.2
The attribute specifies the Ethernet LED status of the AN80i.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), e10hd(2), e10fd(3), e100hd(4), e100fd(5)  

an80iFlowControl 1.3.6.1.4.1.10728.2.1.3.1.3.3
This object specifies if flow control is enabled or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

an80iLowLatencyMode 1.3.6.1.4.1.10728.2.1.3.1.3.4
This object specifies if prioritized low latency mode is enabled or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

an80iEthernetFollowsWireless 1.3.6.1.4.1.10728.2.1.3.1.3.5
This object specifies if the Ethernet follows wireless mode is enabled or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

an80iEthernetFollowsWirelessTimeout 1.3.6.1.4.1.10728.2.1.3.1.3.6
This object specifies if the timeout (seconds) for the Ethernet follows wireless mode (0=infinite).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

redlineAn80iManagObjects 1.3.6.1.4.1.10728.2.1.3.1.4
OBJECT IDENTIFIER    

an80iHttpAccess 1.3.6.1.4.1.10728.2.1.3.1.4.1
This object specifies if Http Access is enabled or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

an80iTelnetAccess 1.3.6.1.4.1.10728.2.1.3.1.4.2
This object specifies if Telnet Access is enabled or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

an80iTelnetPort 1.3.6.1.4.1.10728.2.1.3.1.4.3
This object specifies the Telnet port number.
Status: current Access: read-write
OBJECT-TYPE    
  InetPortNumber  

redlineAn80iSWUpgradeObjects 1.3.6.1.4.1.10728.2.1.3.1.5
OBJECT IDENTIFIER    

an80iSwDownloadTftpAddressType 1.3.6.1.4.1.10728.2.1.3.1.5.1
The INET address type of the software upgrade TFTP server. IPv4 type supported only.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressType  

an80iSwDownloadTftpAddress 1.3.6.1.4.1.10728.2.1.3.1.5.2
The INET address of the TFTP server.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddress  

an80iSwDownloadTftpFile 1.3.6.1.4.1.10728.2.1.3.1.5.3
The image file name as required by the TFTP server.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..63)  

an80iSwDownloadStatus 1.3.6.1.4.1.10728.2.1.3.1.5.4
The status of the current software download.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER download(1), inProgress(2), success(3), failed(4)  

an80iSwDownloadControl 1.3.6.1.4.1.10728.2.1.3.1.5.5
Trigger software upgrade
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noop(1), startUpgrade(2)  

redlineAn80iPmpObjects 1.3.6.1.4.1.10728.2.1.3.2
OBJECT IDENTIFIER    

redlineAn80iPmpWirelesObjects 1.3.6.1.4.1.10728.2.1.3.2.1
OBJECT IDENTIFIER    

an80iRegistrationPeriod 1.3.6.1.4.1.10728.2.1.3.2.1.1
Number of frames between two consecutive registration periods.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..100  

an80iMaximumDistance 1.3.6.1.4.1.10728.2.1.3.2.1.2
Maximum distance in km between the sector controller and one subscriber station.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

an80iRegisteredStations 1.3.6.1.4.1.10728.2.1.3.2.1.3
The number of registered stations on the sector controller.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iRegisteredConnections 1.3.6.1.4.1.10728.2.1.3.2.1.4
The number of registered connections on the sector controller.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iMaxId 1.3.6.1.4.1.10728.2.1.3.2.1.5
The maximum number of ID used to identify links, connections and groups
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..1023  

an80iNextAvailId 1.3.6.1.4.1.10728.2.1.3.2.1.6
The next available ID from the ID pool which is not grater then that defined in 'an80iMaxId'
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iLastModifId 1.3.6.1.4.1.10728.2.1.3.2.1.7
The last modified ID from the ID pool which is not grater then that defined in 'an80iMaxId'
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

an80iSaveIdConfiguration 1.3.6.1.4.1.10728.2.1.3.2.1.8
Save the ID table in the flash memory
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noop(1), save(2)  

redlineAn80iPtpObjects 1.3.6.1.4.1.10728.2.1.3.3
OBJECT IDENTIFIER    

redlineAn80iPtpSystemObjects 1.3.6.1.4.1.10728.2.1.3.3.1
OBJECT IDENTIFIER    

an80iResetStatistics 1.3.6.1.4.1.10728.2.1.3.3.1.1
This object resets wireless and Ethernet counters
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noop(1), reset(2)  

redlineAn80iTrapDefinitions 1.3.6.1.4.1.10728.2.1.3.0
OBJECT IDENTIFIER    

an80iPswdChangeFailTrap 1.3.6.1.4.1.10728.2.1.3.0.1
An event to report the failure of a password change.
Status: current Access: read-write
NOTIFICATION-TYPE    

an80iFirmwareConfigFailTrap 1.3.6.1.4.1.10728.2.1.3.0.2
An event to report the failure of a firmware config.
Status: current Access: read-write
NOTIFICATION-TYPE    

an80iEepromCorruptedTrap 1.3.6.1.4.1.10728.2.1.3.0.3
An event to report the corruption of the EEPROM.
Status: current Access: read-write
NOTIFICATION-TYPE    

an80iHardwareFailTrap 1.3.6.1.4.1.10728.2.1.3.0.4
An event to report the hardware failure.
Status: current Access: read-write
NOTIFICATION-TYPE    

an80iSaveConfigTrap 1.3.6.1.4.1.10728.2.1.3.0.5
An event to report the saving of configuration
Status: current Access: read-write
NOTIFICATION-TYPE    

an80iDFSEventTrap 1.3.6.1.4.1.10728.2.1.3.0.6
An event to report the radar frequency detection
Status: current Access: read-write
NOTIFICATION-TYPE    

an80iIdChangedTrap 1.3.6.1.4.1.10728.2.1.3.0.7
Event that reports the modification in the configuration of an ID.
Status: current Access: read-write
NOTIFICATION-TYPE    

an80iSWUpgradeFailed 1.3.6.1.4.1.10728.2.1.3.0.8
Event that reports the failure of a software upgrade opration.
Status: current Access: read-write
NOTIFICATION-TYPE    

an80iSWUpgradeSuccess 1.3.6.1.4.1.10728.2.1.3.0.9
Event that reports the success of a software upgrade opration.
Status: current Access: read-write
NOTIFICATION-TYPE    

redlineAn80iConformance 1.3.6.1.4.1.10728.2.1.3.5
OBJECT IDENTIFIER    

redlineAn80iGroups 1.3.6.1.4.1.10728.2.1.3.5.1
OBJECT IDENTIFIER    

redlineAn80iCompls 1.3.6.1.4.1.10728.2.1.3.5.2
OBJECT IDENTIFIER    

redlineAn80iPtpPmpGroup 1.3.6.1.4.1.10728.2.1.3.5.1.1
AN80i PTP/PMP objects.
Status: current Access: read-write
OBJECT-GROUP    

redlineAn80iPmpGroup 1.3.6.1.4.1.10728.2.1.3.5.1.2
AN80i PMP objects.
Status: current Access: read-write
OBJECT-GROUP    

redlineAn80iPtpGroup 1.3.6.1.4.1.10728.2.1.3.5.1.3
AN80i PTP objects.
Status: current Access: read-write
OBJECT-GROUP    

redlineAn80iNotificationGroup 1.3.6.1.4.1.10728.2.1.3.5.1.4
The notifications which indicate specific events within the AN80i unit.
Status: current Access: read-write
NOTIFICATION-GROUP    

redlineAn80iCompliance 1.3.6.1.4.1.10728.2.1.3.5.2.1
The compliance statement for AN80i entities that implement this MIB module.
Status: current Access: read-write
MODULE-COMPLIANCE