REDSTONE-IF-MIB

File: REDSTONE-IF-MIB.mib (9801 bytes)

Imported modules

SNMPv2-TC SNMPv2-SMI SNMPv2-CONF
IF-MIB REDSTONE-SMI

Imported symbols

TEXTUAL-CONVENTION MODULE-IDENTITY OBJECT-TYPE
RowStatus MODULE-COMPLIANCE OBJECT-GROUP
ifEntry ifStackHigherLayer ifStackLowerLayer
rsMgmt

Defined Types

RsIfType  
Interface type identification for physical-, link-, and network-layer interfaces.
TEXTUAL-CONVENTION    
  INTEGER ip(0), ppp(1), ds0(2), ds1(3), ds3(4), frameRelay(5), ethernet(6), sonet(7), sonetPath(8), atm(9), aal5(10), atmSubInterface(11), ft1(12), hdlc(13), ipLoopback(14), ipVirtual(15), frSubInterface(16), pppoe(17), pppoeSubInterface(18)  

RsIfEntry  
SEQUENCE    
  rsIfType RsIfType

RsIfInvStackEntry  
SEQUENCE    
  rsIfInvStackStatus RowStatus

Defined Values

rsIfMIB 1.3.6.1.4.1.2773.2.3
The Generic Interfaces MIB for the Redstone Communications Inc. enterprise.
MODULE-IDENTITY    

rsInterfaces 1.3.6.1.4.1.2773.2.3.1
OBJECT IDENTIFIER    

rsIf 1.3.6.1.4.1.2773.2.3.1.1
OBJECT IDENTIFIER    

rsIfObjects 1.3.6.1.4.1.2773.2.3.1.1.1
OBJECT IDENTIFIER    

rsIfTable 1.3.6.1.4.1.2773.2.3.1.1.1.1
This table contains a corresponding entry for each entry found in the standard Generic Interfaces MIB ifTable/ifXTable. The entries in this table contain supplementary generic interface characteristics. Entries in ifTable/ifXTable and in this table are created/deleted as a consequence of hardware detection, or of management configuration via standard or enterprise type-specific interface MIBs.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RsIfEntry

rsIfEntry 1.3.6.1.4.1.2773.2.3.1.1.1.1.1
An entry representing an interface's enterprise-defined generic interface characteristics.
Status: current Access: not-accessible
OBJECT-TYPE    
  RsIfEntry  

rsIfType 1.3.6.1.4.1.2773.2.3.1.1.1.1.1.1
Identifies the type of this interface.
Status: current Access: read-only
OBJECT-TYPE    
  RsIfType  

rsIfInvStackTable 1.3.6.1.4.1.2773.2.3.1.1.1.2
A table containing information on the relationships between the multiple sub-layers of network interfaces. In particular, it contains information on which sub-layers run 'underneath' which other sub-layers, where each sub-layer corresponds to a conceptual row in the ifTable. For example, when the sub-layer with ifIndex value x runs underneath the sub-layer with ifIndex value y, then this table contains: rsIfInvStackStatus.x.y=active For each ifIndex value, I, which identifies an active interface, there are always at least two instantiated rows in this table associated with I. For one of these rows, I is the value of ifStackHigherLayer; for the other, I is the value of ifStackLowerLayer. (If I is not involved in multiplexing, then these are the only two rows associated with I.) For example, two rows exist even for an interface which has no others stacked on top or below it: ifStackStatus.x.0=active ifStackStatus.0.x=active This table contains exactly the same number of rows as the ifStackTable, but the rows appear in a different order.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RsIfInvStackEntry

rsIfInvStackEntry 1.3.6.1.4.1.2773.2.3.1.1.1.2.1
Information on a particular relationship between two sub- layers, specifying that one sub-layer runs underneath the other sub-layer. Each sub-layer corresponds to a conceptual row in the ifTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  RsIfInvStackEntry  

rsIfInvStackStatus 1.3.6.1.4.1.2773.2.3.1.1.1.2.1.1
The status of the relationship between two sub-layers. An instance of this object exists for each instance of the ifStackStatus object, and vice versa. For example, if the variable ifStackStatus.H.L exists, then the variable rsIfInvStackStatus.L.H must also exist, and vice versa. In addition, the two variables always have the same value. However, unlike ifStackStatus, the rsIfInvStackStatus object is NOT write-able. A network management application wishing to change a relationship between sub-layers H and L cannot do so by modifying the value of rsIfInvStackStatus.L.H, but must instead modify the value of ifStackStatus.H.L. After the ifStackTable is modified, the change will be reflected in this table.
Status: current Access: read-only
OBJECT-TYPE    
  RowStatus  

rsIfConformance 1.3.6.1.4.1.2773.2.3.1.1.4
OBJECT IDENTIFIER    

rsIfCompliances 1.3.6.1.4.1.2773.2.3.1.1.4.1
OBJECT IDENTIFIER    

rsIfGroups 1.3.6.1.4.1.2773.2.3.1.1.4.2
OBJECT IDENTIFIER    

rsIfCompliance 1.3.6.1.4.1.2773.2.3.1.1.4.1.1
The compliance statement for entities which implement the Redstone Generic Interfaces MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

rsIfGroup 1.3.6.1.4.1.2773.2.3.1.1.4.2.1
A collection of objects providing management capability capability of generic interfaces in a Redstone product.
Status: current Access: read-only
OBJECT-GROUP    

rsIfInvStackGroup 1.3.6.1.4.1.2773.2.3.1.1.4.2.2
A collection of objects providing inverted information on the layering of MIB-II interfaces.
Status: current Access: read-only
OBJECT-GROUP