RIVERSTONE-NOTIFICATIONS-MIB

File: RIVERSTONE-NOTIFICATIONS-MIB.mib (11256 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
ENTITY-MIB RIVERSTONE-SMI-MIB

Imported symbols

MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
DisplayString MODULE-COMPLIANCE NOTIFICATION-GROUP
entPhysicalDescr riverstoneMibs

Defined Values

rsNotificationsMib 1.3.6.1.4.1.5567.2.33
This module describes the set of notifications specific to the Devices from Riverstone Networks platform. This module represents the total set of enterprise notifications, some are conditionally mandatory depending on platform capabilities.
MODULE-IDENTITY    

rsNotifications 1.3.6.1.4.1.5567.2.33.1
OBJECT IDENTIFIER    

rsNotificationControl 1.3.6.1.4.1.5567.2.33.1.1
OBJECT IDENTIFIER    

rsEnvNotificationGroup 1.3.6.1.4.1.5567.2.33.1.2
OBJECT IDENTIFIER    

rsSyslog2SNMPMapGroup 1.3.6.1.4.1.5567.2.33.1.3
OBJECT IDENTIFIER    

rsEnvNotifications 1.3.6.1.4.1.5567.2.33.1.2.0
OBJECT IDENTIFIER    

rsSyslog2SNMPMapNotifications 1.3.6.1.4.1.5567.2.33.1.3.0
OBJECT IDENTIFIER    

rsEnvirPowerSupplyFailed 1.3.6.1.4.1.5567.2.33.1.2.0.1
A power supply on the sending device has failed. The entPhysicalDescr object identifies the failed supply.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsEnvirPowerSupplyRecovered 1.3.6.1.4.1.5567.2.33.1.2.0.2
A power supply on the sending device has recovered after failure. The entPhysicalDescr object identifies the recovered supply.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsEnvirFanFailed 1.3.6.1.4.1.5567.2.33.1.2.0.3
A Fan tray on the sending device has failed. The entPhysicalDescr object identifies the failed fan tray.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsEnvirFanRecovered 1.3.6.1.4.1.5567.2.33.1.2.0.4
A Fan tray on the sending device has recovered after failure. The entPhysicalDescr object identifies the recovered Fan tray.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsEnvirTempExceeded 1.3.6.1.4.1.5567.2.33.1.2.0.5
A temperature inside the chassis on the sending device has exceeded normal operating temperature. The entPhysicalDescr object identifies the module that has the temperature sensor.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsEnvirTempNormal 1.3.6.1.4.1.5567.2.33.1.2.0.6
A temperature inside the chassis on the sending device has returned to normal operating temperature. The entPhysicalDescr object identifies the module that has the temperature sensor.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsEnvirHotSwapIn 1.3.6.1.4.1.5567.2.33.1.2.0.7
A module has been inserted into the chassis. The object entPhysicalDescr identifies the module. The module can be a card for the main bay or a switching fabric in the switching fabric bay.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsEnvirHotSwapOut 1.3.6.1.4.1.5567.2.33.1.2.0.8
A module has been turned off or removed from the chassis. The object entPhysicalDescr identifies the module. The module can be a card for the main bay or a switching fabric in the switching fabric.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsEnvirBackupControlModuleOnline 1.3.6.1.4.1.5567.2.33.1.2.0.9
A backup control module that was in standby mode has taken over for a failed primary control module. The objec entPhysicalDescr identifies the now active control module.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsEnvirSwitchingFabricFailure 1.3.6.1.4.1.5567.2.33.1.2.0.10
The primary switching fabric that was in standby mode has failed. The object entPhysicalDescr identifies the failed switching fabric. If there is a backup switching fabric and if it comes up ok, rsEnvirSwitchingFabricFailover would be sent after this one.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsEnvirSwitchingFabricFailover 1.3.6.1.4.1.5567.2.33.1.2.0.11
A backup switching fabric that was in standby mode has taken over for a failed primary switching fabric. The object entPhysicalDescr identifies the now active switching fabric. This would be sent after sending rsEnvirSwitchingFabricFailure.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsEnvirTempTooLow 1.3.6.1.4.1.5567.2.33.1.2.0.12
A temperature inside the chassis on the sending device has fallen below normal operating temperature. The entPhysicalDescr object identifies the module that has the temperature sensor.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsS2SModuleId 1.3.6.1.4.1.5567.2.33.1.3.1
Name of the software module that is generating this syslog message.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

rsS2SSeverity 1.3.6.1.4.1.5567.2.33.1.3.2
Severity of the event that caused the syslog message to be generated.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fatal(1), error(2), warning(3), information(4)  

rsS2SMessage 1.3.6.1.4.1.5567.2.33.1.3.3
Text message describing the event that resulted in the syslog message being generated. Any instance identifiers will be embedded in this message text.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..256)  

rsSyslog2SNMPMap 1.3.6.1.4.1.5567.2.33.1.3.0.1
A backup control module that was in standby mode has taken over for a failed primary control module. The objec entPhysicalDescr identifies the now active control module.
Status: current Access: read-only
NOTIFICATION-TYPE    

rsNotificationConformance 1.3.6.1.4.1.5567.2.33.2
OBJECT IDENTIFIER    

rsNotificationCompliances 1.3.6.1.4.1.5567.2.33.2.1
OBJECT IDENTIFIER    

rsEnvNotificationConfGroup 1.3.6.1.4.1.5567.2.33.2.2
OBJECT IDENTIFIER    

rsS2SNotificationConfGroup 1.3.6.1.4.1.5567.2.33.2.3
OBJECT IDENTIFIER    

rsNotificationComplianceV10 1.3.6.1.4.1.5567.2.33.2.1.1
The compliance statement for the RIVERSTONE-NOTIFICATIONS-MIB.
Status: obsolete Access: read-only
MODULE-COMPLIANCE    

rsNotificationComplianceV11 1.3.6.1.4.1.5567.2.33.2.1.2
Add compliance that includes the two new notifications.
Status: current Access: read-only
MODULE-COMPLIANCE    

rsNotificationComplianceV12 1.3.6.1.4.1.5567.2.33.2.1.3
Add compliance that includes the two new notifications.
Status: current Access: read-only
MODULE-COMPLIANCE    

rsNotificationConfGroupV10 1.3.6.1.4.1.5567.2.33.2.2.1
A base set of notifications for chassis based devices.
Status: current Access: read-only
NOTIFICATION-GROUP    

rsNotificationSwitchingFabric 1.3.6.1.4.1.5567.2.33.2.2.2
A set of switching fabric notifications.
Status: current Access: read-only
NOTIFICATION-GROUP    

rsNotificationSyslog2SNMPMap 1.3.6.1.4.1.5567.2.33.2.3.1
A notification to map syslog message to SNMP.
Status: current Access: read-only
NOTIFICATION-GROUP