ROOMALERT12E-MIB
File:
ROOMALERT12E-MIB.mib (16857 bytes)
Imported modules
Imported symbols
Defined Values
avtech |
1.3.6.1.4.1.20916 |
OBJECT IDENTIFIER |
|
|
|
products |
1.3.6.1.4.1.20916.1 |
OBJECT IDENTIFIER |
|
|
|
sensors |
1.3.6.1.4.1.20916.1.9.1 |
OBJECT IDENTIFIER |
|
|
|
lightTower |
1.3.6.1.4.1.20916.1.9.2 |
OBJECT IDENTIFIER |
|
|
|
switch1 |
1.3.6.1.4.1.20916.1.9.1.5 |
OBJECT IDENTIFIER |
|
|
|
switch2 |
1.3.6.1.4.1.20916.1.9.1.6 |
OBJECT IDENTIFIER |
|
|
|
switch3 |
1.3.6.1.4.1.20916.1.9.1.7 |
OBJECT IDENTIFIER |
|
|
|
switch4 |
1.3.6.1.4.1.20916.1.9.1.8 |
OBJECT IDENTIFIER |
|
|
|
analog |
1.3.6.1.4.1.20916.1.9.1.9 |
OBJECT IDENTIFIER |
|
|
|
relay |
1.3.6.1.4.1.20916.1.9.1.10 |
OBJECT IDENTIFIER |
|
|
|
traps |
1.3.6.1.4.1.20916.1.9.3 |
OBJECT IDENTIFIER |
|
|
|
internal-sen-1 |
1.3.6.1.4.1.20916.1.9.1.1.1 |
If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
internal-sen-2 |
1.3.6.1.4.1.20916.1.9.1.1.2 |
If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Power reading in Watts. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
internal-sen-3 |
1.3.6.1.4.1.20916.1.9.1.1.3 |
If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor, this value represents the Voltage reading in Volts. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
internal-sen-4 |
1.3.6.1.4.1.20916.1.9.1.1.4 |
If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Reference reading in Volts. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
internal-sen-5 |
1.3.6.1.4.1.20916.1.9.1.1.5 |
If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
internal-sen-6 |
1.3.6.1.4.1.20916.1.9.1.1.6 |
Represents the sensor's label/ |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
analog-1 |
1.3.6.1.4.1.20916.1.9.1.9.1 |
The current status of the Room Alert 12E analog input (0-5VDC). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
analog-2 |
1.3.6.1.4.1.20916.1.9.1.9.2 |
The analog sensor's label. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
relay-1 |
1.3.6.1.4.1.20916.1.9.1.10.1 |
The current status of the Room Alert 12E relay output. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
relay-2 |
1.3.6.1.4.1.20916.1.9.1.10.2 |
The relay output's label. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
digital-sen1-1 |
1.3.6.1.4.1.20916.1.9.1.2.1 |
If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen1-2 |
1.3.6.1.4.1.20916.1.9.1.2.2 |
If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Power reading in Watts. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen1-3 |
1.3.6.1.4.1.20916.1.9.1.2.3 |
If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor, this value represents the Voltage reading in Volts. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen1-4 |
1.3.6.1.4.1.20916.1.9.1.2.4 |
If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Reference reading in Volts. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen1-5 |
1.3.6.1.4.1.20916.1.9.1.2.5 |
If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen1-6 |
1.3.6.1.4.1.20916.1.9.1.2.6 |
Represents the sensor's label/ |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
digital-sen2-1 |
1.3.6.1.4.1.20916.1.9.1.3.1 |
If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen2-2 |
1.3.6.1.4.1.20916.1.9.1.3.2 |
If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Power reading in Watts. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen2-3 |
1.3.6.1.4.1.20916.1.9.1.3.3 |
If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor, this value represents the Voltage reading in Volts. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen2-4 |
1.3.6.1.4.1.20916.1.9.1.3.4 |
If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Reference reading in Volts. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen2-5 |
1.3.6.1.4.1.20916.1.9.1.3.5 |
If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen2-6 |
1.3.6.1.4.1.20916.1.9.1.3.6 |
Represents the sensor's label/ |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
digital-sen3-1 |
1.3.6.1.4.1.20916.1.9.1.4.1 |
If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen3-2 |
1.3.6.1.4.1.20916.1.9.1.4.2 |
If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Power reading in Watts. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen3-3 |
1.3.6.1.4.1.20916.1.9.1.4.3 |
If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor, this value represents the Voltage reading in Volts. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen3-4 |
1.3.6.1.4.1.20916.1.9.1.4.4 |
If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Reference reading in Volts. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen3-5 |
1.3.6.1.4.1.20916.1.9.1.4.5 |
If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
digital-sen3-6 |
1.3.6.1.4.1.20916.1.9.1.4.6 |
Represents the sensor's label/ |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
switch-sen1-1 |
1.3.6.1.4.1.20916.1.9.1.5.1 |
The reading for switch sensor 1 (0 = OPEN, 1 = CLOSED). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
switch-sen1-2 |
1.3.6.1.4.1.20916.1.9.1.5.2 |
The label for switch sensor 1. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
switch-sen2 |
1.3.6.1.4.1.20916.1.9.1.6.1 |
The reading for switch sensor 2 (0 = OPEN, 1 = CLOSED). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
switch-sen2-2 |
1.3.6.1.4.1.20916.1.9.1.6.2 |
The label for switch sensor 2. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
switch-sen3 |
1.3.6.1.4.1.20916.1.9.1.7.1 |
The reading for switch sensor 3 (0 = OPEN, 1 = CLOSED). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
switch-sen3-2 |
1.3.6.1.4.1.20916.1.9.1.7.2 |
The label for switch sensor 3. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
switch-sen4 |
1.3.6.1.4.1.20916.1.9.1.8.1 |
The reading for switch sensor 4 (0 = OPEN, 1 = CLOSED). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
switch-sen4-2 |
1.3.6.1.4.1.20916.1.9.1.8.2 |
The label for switch sensor 4. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
alarmmessage |
1.3.6.1.4.1.20916.1.9.3.1 |
Last Alarm Message |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
lightTower-RE |
1.3.6.1.4.1.20916.1.9.2.1 |
The status of the red LED on the Light Tower. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
lightTower-OR |
1.3.6.1.4.1.20916.1.9.2.2 |
The status of the orange LED on the Light Tower. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
lightTower-GR |
1.3.6.1.4.1.20916.1.9.2.3 |
The status of the green LED on the Light Tower. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
lightTower-WH |
1.3.6.1.4.1.20916.1.9.2.4 |
The status of the white LED on the Light Tower. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
lightTower-BL |
1.3.6.1.4.1.20916.1.9.2.5 |
The status of the blue LED on the Light Tower. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
lightTower-A1 |
1.3.6.1.4.1.20916.1.9.2.6 |
The status of the 1st audio alarm on the Light Tower. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
lightTower-A2 |
1.3.6.1.4.1.20916.1.9.2.7 |
The status of the 2nd audio alarm on the Light Tower. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
lightTower-RL |
1.3.6.1.4.1.20916.1.9.2.8 |
The status of the LTA's on-board relay output |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..1 |
|
tempalarm1-12E |
1 |
A tempalarm1 trap signifies that the current
temperature on external sensor 1 is outside the
defined high or low threshold. |
TRAP-TYPE |
|
|
|
room-alert-12E-snmp-trap |
2 |
A room-alert-12E-snmp-trap indicates that an alarm
condition has occurred on the sensor inidcated
by the alarmMessage variable. |
TRAP-TYPE |
|
|
|
tempalarm2-12E |
3 |
A tempalarm2 trap signifies that the current
temperature on external sensor 2 is outside the
defined high or low threshold. |
TRAP-TYPE |
|
|
|
tempclear2-12E |
4 |
A tempclear2 trap signifies that the current
temperature on external sensor 2 has returned to
a normal condition and is within the defined
high or low threshold. |
TRAP-TYPE |
|
|
|
tempalarm3-12E |
5 |
A tempalarm3 trap signifies that the current
temperature on external sensor 3 is outside the
defined high or low threshold. |
TRAP-TYPE |
|
|
|
tempclear3-12E |
6 |
A tempclear3 trap signifies that the current
temperature on external sensor 3 has returned to
a normal condition and is within the defined
high or low threshold. |
TRAP-TYPE |
|
|
|
humidityalarm1-12E |
7 |
A humidityalarm1 trap signifies that the current
humidity on external sensor 1 is outside the
defined high or low threshold. |
TRAP-TYPE |
|
|
|
humidityclear1-12E |
8 |
A humidityclear1 trap signifies that the current
humidity on external sensor 1 has returned to
a normal condition and is within the defined
high or low threshold. |
TRAP-TYPE |
|
|
|
humidityalarm2-12E |
9 |
A humidityalarm2 trap signifies that the current
humidity on external sensor 2 is outside the
defined high or low threshold. |
TRAP-TYPE |
|
|
|
humidityclear2-12E |
10 |
A humidityclear2 trap signifies that the current
humidity on external sensor 2 has returned to
a normal condition and is within the defined
high or low threshold. |
TRAP-TYPE |
|
|
|
humidityalarm3-12E |
11 |
A humidityalarm3 trap signifies that the current
humidity on external sensor 3 is outside the
defined high or low threshold. |
TRAP-TYPE |
|
|
|
humidityclear3-12E |
12 |
A humidityclear3 trap signifies that the current
humidity on external sensor 3 has returned to
a normal condition and is within the defined
high or low threshold. |
TRAP-TYPE |
|
|
|
switchalarm1-12E |
13 |
A switchalarm1 trap signifies that switch sensor 1
is in an alarm state. |
TRAP-TYPE |
|
|
|
switchclear1-12E |
14 |
A switchclear1 trap signifies that the switch sensor 1
has returned to a normal state. |
TRAP-TYPE |
|
|
|
switchalarm2-12E |
15 |
A switchalarm2 trap signifies that switch sensor 2
is in an alarm state. |
TRAP-TYPE |
|
|
|
switchclear2-12E |
16 |
A switchclear2 trap signifies that the switch sensor 2
has returned to a normal state. |
TRAP-TYPE |
|
|
|
switchalarm3-12E |
17 |
A switchalarm3 trap signifies that switch sensor 3
is in an alarm state. |
TRAP-TYPE |
|
|
|
switchclear3-12E |
18 |
A switchclear3 trap signifies that the switch sensor 3
has returned to a normal state. |
TRAP-TYPE |
|
|
|
switchalarm4-12E |
19 |
A switchalarm4 trap signifies that switch sensor 4
is in an alarm state. |
TRAP-TYPE |
|
|
|
switchclear4-12E |
20 |
A switchclear4 trap signifies that the switch sensor 4
has returned to a normal state. |
TRAP-TYPE |
|
|
|