SATELCOM-MIB

File: SATELCOM-MIB.mib (233527 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
RFC-1215

Imported symbols

Counter NetworkAddress enterprises
DisplayString mib-2 OBJECT-TYPE
TRAP-TYPE

Defined Types

CtrlStatEntry  
SEQUENCE    
  ctrlStatIndex INTEGER
  ctrlStatName DisplayString
  ctrlStatType INTEGER
  ctrlStatSubType INTEGER
  ctrlStatNumberChannels INTEGER
  ctrlStatFirstChannelIndex INTEGER
  ctrlStatCRCErrors Counter
  ctrlStatTotalCallSetUps Counter
  ctrlStatCurrentCalls INTEGER
  ctrlStatDataIn Counter
  ctrlStatDataOut Counter
  ctrlStatDataFramesIn Counter
  ctrlStatDataFramesOut Counter
  ctrlStatDataFrameRateIn INTEGER
  ctrlStatDataFrameRateOut INTEGER
  ctrlStatCallsReceived Counter
  ctrlStatCallsSent Counter
  ctrlStatClearsReceived Counter
  ctrlStatRetransmissions Counter
  ctrlStatRejects Counter
  ctrlStatState INTEGER
  ctrlStatSubState INTEGER
  ctrlStatNoTries Counter
  ctrlStatOptions INTEGER
  ctrlStatLCGN INTEGER
  ctrlStatResetsReceived Counter
  ctrlStatInterruptsReceived Counter
  ctrlStatOuputQueueLength INTEGER
  ctrlStatStationAddress DisplayString
  ctrlStatDestinationAddress DisplayString
  ctrlStatEIA DisplayString
  ctrlStatSdlcOptions INTEGER
  ctrlStatArpRequestRec INTEGER
  ctrlStatArpRequestSent INTEGER
  ctrlStatArpResponsesRec INTEGER
  ctrlStatTestType INTEGER
  ctrlStatTestSet INTEGER
  ctrlStatTest INTEGER
  ctrlStatLstate INTEGER
  ctrlStatRstate INTEGER

CtrlParamEntry  
SEQUENCE    
  ctrlParamIndex INTEGER
  ctrlParamName DisplayString
  ctrlParamType INTEGER
  ctrlParamSubType INTEGER
  ctrlParamNoChannels INTEGER
  ctrlParamSpeed INTEGER
  ctrlParamInterfaceType INTEGER
  ctrlParamPacketSize INTEGER
  ctrlParamV54Modem INTEGER
  ctrlParamAddress INTEGER
  ctrlParamOptions INTEGER
  ctrlParamInitFrame INTEGER
  ctrlParamT1 INTEGER
  ctrlParamTries INTEGER
  ctrlParamKLevel2 INTEGER
  ctrlParamKLevel3 INTEGER
  ctrlParamLineGroup INTEGER
  ctrlParamLCGN INTEGER
  ctrlParamLCNOffset INTEGER
  ctrlParamAddressGroup INTEGER
  ctrlParamFrameSequence INTEGER
  ctrlParamCallTimeOut INTEGER
  ctrlParamErrorThreshold INTEGER
  ctrlParamLoopBarPriority INTEGER
  ctrlParamExtendedCallMgmt INTEGER
  ctrlParamOptionalTimers INTEGER
  ctrlParamOptionalFlags INTEGER
  ctrlParamTransportLevelType INTEGER
  ctrlParamTransportClass INTEGER
  ctrlParamDefaultWindowSize INTEGER
  ctrlParamDisableFlowControl INTEGER
  ctrlParamTSAPFormat INTEGER
  ctrlParamMaximumTPDUSize INTEGER
  ctrlParamTTRTime INTEGER
  ctrlParamTWRTime INTEGER
  ctrlParamDestinationAddress DisplayString
  ctrlParamDSAP INTEGER
  ctrlParamSSAP INTEGER
  ctrlParamSDLCOptions INTEGER
  ctrlParamPrimaryStation INTEGER
  ctrlParamIdleDetectTime INTEGER
  ctrlParamPollInterval INTEGER
  ctrlParamDuplex INTEGER
  ctrlParamTransmitDelay INTEGER
  ctrlParamSlowPollTimer INTEGER
  ctrlParamMaxCallInterval INTEGER
  ctrlParamMaxCallCycles INTEGER
  ctrlParamGroupPoll INTEGER
  ctrlParamDelayToRTSLow INTEGER
  ctrlParamDelayToCTSHigh INTEGER
  ctrlParamInputSyncDeletion INTEGER
  ctrlParamOutputSyncInsertion INTEGER
  ctrlParamDCDFilter INTEGER
  ctrlParamInhibitTimeFill INTEGER
  ctrlParamDirectedBroadcasts INTEGER
  ctrlParamDefaultLocalPrinter INTEGER
  ctrlParamNewLANInterface INTEGER
  ctrlParamNewSerialInterface INTEGER
  ctrlParamDlci INTEGER
  ctrlParamMode INTEGER
  ctrlParamLmi INTEGER
  ctrlParamKeepAliveTimer INTEGER
  ctrlParamStatusEnquiryInterval INTEGER
  ctrlParamBandwidth INTEGER
  ctrlParamBurstCommit INTEGER
  ctrlParamBurstEligibility INTEGER

ChanStatEntry  
SEQUENCE    
  chanStatIndex INTEGER
  chanStatName DisplayString
  chanStatControllerIndex INTEGER
  chanStatNameCtrlName DisplayString
  chanStatConnectedToChannelIndex INTEGER
  chanStatState INTEGER
  chanStatSessionStatus INTEGER
  chanStatEIA INTEGER
  chanStatTotalFramesIn Counter
  chanStatTotalFramesOut Counter
  chanStatTotalCharsIn Counter
  chanStatTotalCharsOut Counter
  chanStatTxWindow INTEGER
  chanStatRxWindow INTEGER
  chanStatTxSize INTEGER
  chanStatRxSize INTEGER
  chanStatCause INTEGER
  chanStatDiagnostic INTEGER
  chanStatResetCause INTEGER
  chanStatResetDiagnostic INTEGER
  chanStatResetCauseReceived INTEGER
  chanStatResetDiagReceived INTEGER
  chanStatLevel3State INTEGER
  chanStatCallPriority INTEGER
  chanStatResourcePriority INTEGER
  chanStatPadEnable INTEGER
  chanStatPortMatch INTEGER
  chanStatPrimaryStation INTEGER
  chanStatSDLCState INTEGER
  chanStatQLLCState INTEGER
  chanStatSDLCTransmitState INTEGER
  chanStatPolls INTEGER
  chanStatStationAddress INTEGER
  chanStatXIDIdentification DisplayString
  chanStatTries INTEGER
  chanStatWindow INTEGER
  chanStatLUActive INTEGER
  chanStatBindActive INTEGER
  chanStatLUType INTEGER
  chanStatBreaksReceived Counter
  chanStatFramingErrors Counter
  chanStatInputOverruns Counter
  chanStatParityErrors Counter
  chanStatTerminalType INTEGER
  chanStatCircuitType INTEGER
  chanStatOptions INTEGER
  chanStatBuffers INTEGER
  chanStatDiscMode INTEGER
  chanStatMenuNumber INTEGER
  chanStatHelpNumber INTEGER
  chanStatNewsNumber INTEGER
  chanStatPadRecall INTEGER
  chanStatEcho INTEGER
  chanStatDataForwarding INTEGER
  chanStatDelay INTEGER
  chanStatDRI INTEGER
  chanStatPadSignals INTEGER
  chanStatBreak INTEGER
  chanStatPadding INTEGER
  chanStatFold INTEGER
  chanStatDRO INTEGER
  chanStatLFI INTEGER
  chanStatLFPad INTEGER
  chanStatEdit INTEGER
  chanStatCharDel INTEGER
  chanStatBufferDel INTEGER
  chanStatDisp INTEGER
  chanStatEditServiceSignals INTEGER
  chanStatEchoMask INTEGER
  chanStatParityTreatment INTEGER
  chanStatPageWait INTEGER
  chanStatForce INTEGER
  chanStatBreakChar INTEGER
  chanStatNetworkParity INTEGER
  chanStatEscapeDelay INTEGER
  chanStatDestTsap DisplayString
  chanStatTransportLevelState INTEGER
  chanStatLinkState INTEGER
  chanStatProtocolState INTEGER
  chanStatProtocol INTEGER
  chanStatIdentity INTEGER
  chanStatDlciRxDe Counter
  chanStatDlciTxDe Counter
  chanStatDlciRxFecn Counter
  chanStatDlciTxFecn Counter
  chanStatDlciRxBecn Counter
  chanStatDlciTxBecn Counter
  chanStatConnectedToControllerIndex INTEGER

ChanParamEntry  
SEQUENCE    
  chanParamIndex INTEGER
  chanParamName DisplayString
  chanParamDRCMask DisplayString
  chanParamTerminalType INTEGER
  chanParamCircuitType INTEGER
  chanParamOptions INTEGER
  chanParamBuffers INTEGER
  chanParamDiscMode INTEGER
  chanParamMenuNumber INTEGER
  chanParamHelpNumber INTEGER
  chanParamNewsNumber INTEGER
  chanParamCallPriority INTEGER
  chanParamResourcePriority INTEGER
  chanParamPadEnable INTEGER
  chanParamPadRecall INTEGER
  chanParamEcho INTEGER
  chanParamDataForwarding INTEGER
  chanParamDelay INTEGER
  chanParamDRI INTEGER
  chanParamPadSignals INTEGER
  chanParamBreak INTEGER
  chanParamPadding INTEGER
  chanParamFold INTEGER
  chanParamDRO INTEGER
  chanParamLFI INTEGER
  chanParamLFPad INTEGER
  chanParamEdit INTEGER
  chanParamCharDel INTEGER
  chanParamBufferDel INTEGER
  chanParamDisp INTEGER
  chanParamEditServiceSignals INTEGER
  chanParamEchoMask INTEGER
  chanParamParityTreatment INTEGER
  chanParamPageWait INTEGER
  chanParamForce INTEGER
  chanParamBreakChar INTEGER
  chanParamNetworkParity INTEGER
  chanParamEscapeDelay INTEGER
  chanParamStationAddress INTEGER
  chanParamProvideXID INTEGER
  chanParamMode INTEGER
  chanParamPortMatch INTEGER
  chanParamReverseTelnetPort INTEGER
  chanParamBroadcastFilterTimer INTEGER
  chanParamInhibitLearning INTEGER
  chanParamRetainSession INTEGER
  chanParamPrinterType INTEGER
  chanParamScreenPrinter INTEGER
  chanParamLocalPrinter INTEGER
  chanParamInterlockBind INTEGER
  chanParamRedirectPrintTo INTEGER
  chanParamLUBase INTEGER
  chanParamLUOffset INTEGER
  chanParamLUTotal INTEGER
  chanParamDlciBase INTEGER
  chanParamDlciAdjacentBase INTEGER
  chanParamDlciPriority INTEGER
  chanParamDlciATM INTEGER
  chanParamDlciCir INTEGER
  chanParamDlciBc INTEGER
  chanParamDlciBe INTEGER
  chanParamDlciDe INTEGER
  chanParamDlciProtocol INTEGER
  chanParamDlciDsap INTEGER
  chanParamDlciSsap INTEGER
  chanParamDlciPutype INTEGER

X25Entry  
SEQUENCE    
  x25Index INTEGER
  x25Name DisplayString
  x25AddressGroup INTEGER
  x25Address DisplayString
  x25UserData DisplayString

NameEntry  
SEQUENCE    
  nameIndex INTEGER
  nameName DisplayString
  nameDRCMask DisplayString
  nameCallPriority INTEGER
  nameBilling INTEGER
  nameOptions INTEGER

MacEntry  
SEQUENCE    
  macIndex INTEGER
  macName DisplayString
  macFunction INTEGER
  macOptions INTEGER
  macSelector DisplayString
  macGenerator DisplayString

IlanEntry  
SEQUENCE    
  ilanIndex INTEGER
  ilanName DisplayString
  ilanOptions INTEGER
  ilanEthernetAddress DisplayString
  ilanTSAP DisplayString

ElogEntry  
SEQUENCE    
  elogIndex INTEGER
  elogRecord DisplayString

Defined Values

satelcom 1.3.6.1.4.1.397
OBJECT IDENTIFIER    

products 1.3.6.1.4.1.397.1
OBJECT IDENTIFIER    

base 1.3.6.1.4.1.397.2
OBJECT IDENTIFIER    

controller 1.3.6.1.4.1.397.3
OBJECT IDENTIFIER    

channel 1.3.6.1.4.1.397.4
OBJECT IDENTIFIER    

x25File 1.3.6.1.4.1.397.5
OBJECT IDENTIFIER    

nameFile 1.3.6.1.4.1.397.6
OBJECT IDENTIFIER    

passFile 1.3.6.1.4.1.397.7
OBJECT IDENTIFIER    

macFile 1.3.6.1.4.1.397.8
OBJECT IDENTIFIER    

ilanFile 1.3.6.1.4.1.397.9
OBJECT IDENTIFIER    

elogFile 1.3.6.1.4.1.397.10
OBJECT IDENTIFIER    

megaPAC-E-cpu-C 1.3.6.1.4.1.397.1.1
OBJECT IDENTIFIER    

megaPAC-N-series 1.3.6.1.4.1.397.1.2
OBJECT IDENTIFIER    

megaPAC-E-cpu-D 1.3.6.1.4.1.397.1.3
OBJECT IDENTIFIER    

megaCARD 1.3.6.1.4.1.397.1.4
OBJECT IDENTIFIER    

arm-Router 1.3.6.1.4.1.397.1.5
OBJECT IDENTIFIER    

megaPAC-V-cpu-8 1.3.6.1.4.1.397.1.6
OBJECT IDENTIFIER    

megaPAC-V-cpu-16 1.3.6.1.4.1.397.1.7
OBJECT IDENTIFIER    

megaPAC-V-cpu-68040 1.3.6.1.4.1.397.1.8
OBJECT IDENTIFIER    

megaPAD 1.3.6.1.4.1.397.1.9
OBJECT IDENTIFIER    

megapac-2001 1.3.6.1.4.1.397.1.10
OBJECT IDENTIFIER    

micropad-2 1.3.6.1.4.1.397.1.11
OBJECT IDENTIFIER    

micropad-4 1.3.6.1.4.1.397.1.12
OBJECT IDENTIFIER    

micropad-8 1.3.6.1.4.1.397.1.13
OBJECT IDENTIFIER    

duo-Card-MBOX 1.3.6.1.4.1.397.1.14
OBJECT IDENTIFIER    

duo-Card-System 1.3.6.1.4.1.397.1.15
OBJECT IDENTIFIER    

megaBox-CPU-C 1.3.6.1.4.1.397.1.16
OBJECT IDENTIFIER    

megaBox-CPU-D 1.3.6.1.4.1.397.1.17
OBJECT IDENTIFIER    

megaBox-CPU-E 1.3.6.1.4.1.397.1.18
OBJECT IDENTIFIER    

megaPac-E-CPU-C-Dual 1.3.6.1.4.1.397.1.19
OBJECT IDENTIFIER    

megaPac-E-CPU-D-Dual 1.3.6.1.4.1.397.1.20
OBJECT IDENTIFIER    

megaPac-E-CPU-E-Dual 1.3.6.1.4.1.397.1.21
OBJECT IDENTIFIER    

megaPac-E-CPU-C-Dual-Fan 1.3.6.1.4.1.397.1.22
OBJECT IDENTIFIER    

megaPac-E-CPU-D-Dual-Fan 1.3.6.1.4.1.397.1.23
OBJECT IDENTIFIER    

megaPac-E-CPU-E-Dual-Fan 1.3.6.1.4.1.397.1.24
OBJECT IDENTIFIER    

megaPac-E-CPU-C-Dual-Fan-48V 1.3.6.1.4.1.397.1.25
OBJECT IDENTIFIER    

megaPac-E-CPU-D-Dual-Fan-48V 1.3.6.1.4.1.397.1.26
OBJECT IDENTIFIER    

megaPac-E-CPU-E-Dual-Fan-48V 1.3.6.1.4.1.397.1.27
OBJECT IDENTIFIER    

megaPAC-E-cpu-E 1.3.6.1.4.1.397.1.28
OBJECT IDENTIFIER    

megaPac-V-Dual-PSU 1.3.6.1.4.1.397.1.29
OBJECT IDENTIFIER    

megaPac-V-Dual-PSU-48V 1.3.6.1.4.1.397.1.30
OBJECT IDENTIFIER    

megapac-20EM 1.3.6.1.4.1.397.1.31
OBJECT IDENTIFIER    

megapac-21EM 1.3.6.1.4.1.397.1.32
OBJECT IDENTIFIER    

megapac-2002 1.3.6.1.4.1.397.1.33
OBJECT IDENTIFIER    

megapac-2003 1.3.6.1.4.1.397.1.34
OBJECT IDENTIFIER    

baseVersion 1.3.6.1.4.1.397.2.1
Software Version. The software version currently running. Defined as YMMR (i.e. Year, Month, Revision
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

baseRestartTime 1.3.6.1.4.1.397.2.2
BASE Restart Time. The time and data of the last system restart (i.e. power-on or last BOOT)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(20)  

baseMaxPacketSize 1.3.6.1.4.1.397.2.3
Node Maximum Packet Size. The maximum single buffer size available on the MegaPAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

baseBuffPoolMax 1.3.6.1.4.1.397.2.4
Node Buffer Pool Maximum. The maximum number of buffers available temporary storage of transitting data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

baseBuffPoolNow 1.3.6.1.4.1.397.2.5
Node Current Buffer Pool. The current number of free buffers available temporary storage of transitting data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

baseBufferPoolLowest 1.3.6.1.4.1.397.2.6
Node Buffer Pool Lowest. The lowest value the buffer pool has ever reached.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

baseBufferPoolEmpty 1.3.6.1.4.1.397.2.7
Node Buffer Pool Empty. The number of times that the free buffer pool has fallen below the minimum buffer threshold 'baseBuffThreshold'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

baseStatBufferThreshold 1.3.6.1.4.1.397.2.8
Node Buffer Threshold. When the number of buffers in the free buffer pool reaches this threshold, flow control will occur.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..1000  

baseMemorySize 1.3.6.1.4.1.397.2.9
Node Memory Size. The size of the system memory installed in the MegaPAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

baseDataFramesIn 1.3.6.1.4.1.397.2.10
Node Frames In. The total number of frames received by the MegaPAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

baseDataFramesOut 1.3.6.1.4.1.397.2.11
Node Frames Out. The total number of frames transmitted by the MegaPAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

baseDataFrameRateIn 1.3.6.1.4.1.397.2.12
Node Frame Rate In. The rate measured in frames per second that the MegaPAC is currently receiving frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

baseDataFrameRateOut 1.3.6.1.4.1.397.2.13
Node Frames Rate Out. The rate measured in frames per second that the MegaPAC is currently transmitting frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

baseTotalCallSetUps 1.3.6.1.4.1.397.2.14
Node Total Call Set ups. The total number of calls successfully established by the MegaPAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

baseCurrentCalls 1.3.6.1.4.1.397.2.15
Current calls. The number of calls currently active on the MegaPAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

baseRetransmissions 1.3.6.1.4.1.397.2.16
Node Retransmissions. The total number of frames which have been retransmitted by the MegaPAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

baseRejects 1.3.6.1.4.1.397.2.17
Node Rejects. The total number of frames that have been rejected by the MegaPAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

baseTotalTransportCalls 1.3.6.1.4.1.397.2.18
Node Total Transport calls. The total number of transport calls established by the MegaPAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

baseCurrentTransportCalls 1.3.6.1.4.1.397.2.19
Current Transport Calls. The number of transport calls currently active on the MegaPAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

baseRunStatus 1.3.6.1.4.1.397.2.20
Node Run Status. This parameter indicates whether the operating system has been 'Booted' from RAM (TELELOAD) or EPROM (default).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER prom(1), ram(2)  

baseReports 1.3.6.1.4.1.397.2.21
Node Reporting channel. The name of the logical resource (channel) that the system reports will be directed to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4)  

baseSessionStatistics 1.3.6.1.4.1.397.2.22
Node Session Statistics reporting channel. The name of the logical resource (channel) that the system session statistics will be directed to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4)  

baseBufferThreshold 1.3.6.1.4.1.397.2.23
Node Buffer Threshold. The threshold before flow control is invoked
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..1000  

baseInitialPresentationTimer 1.3.6.1.4.1.397.2.24
Node Initial Presentation Timer. The maximum time allowed between initial connection to the presentation service and the user entering a valid resource. The call will be disconnected if this timer elapses.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..300  

baseSecondaryPresentationTimer 1.3.6.1.4.1.397.2.25
Node Secondary Presentation Timer. After a call has been cleared by the Host DTE the user has the option to use the presentation service to establish another call, failure to do so within this time period will result in the initial call being cleared.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..300  

baseInactivityDetectTimer 1.3.6.1.4.1.397.2.26
Node Inactivity Timer. This timer will cause calls to be cleared if the IDLE option has been configured on the channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..30  

baseSegmentAccounting 1.3.6.1.4.1.397.2.27
Node Segment Accounting. This parameter causes the frames in/out parameters to be displayed in terms of 64 byte SEGMENTS rather than frames.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

baseTerminalEmulationBuffers 1.3.6.1.4.1.397.2.28
Terminal Emulation Buffers. The number of system buffers allocated for Terminal Emulation purposes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..640  

baseTransportBuffers 1.3.6.1.4.1.397.2.29
Transport Buffers. The number of transport buffers allocated for TP 0,2,3,4 sessions.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048  

baseCountrySettings 1.3.6.1.4.1.397.2.30
Country Setting. Invokes the ASCII representation of the Japanese character set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), japn(2)  

baseTeleloadEnabled 1.3.6.1.4.1.397.2.31
Teleload enable. If set to yes the MegaPAC software may be downloaded by ASCII file transfer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2), k256(3), k160(129)  

baseDefaultToPromCompatible 1.3.6.1.4.1.397.2.32
Cold Boot From PROM. If set to yes the MegaPAC software may be downloaded by ASCII file transfer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

baseCommand 1.3.6.1.4.1.397.2.33
Allows SNMP manager to execute commands.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), systemBoot(2), restart(3), stop(4), dele(5), clearVcp(6), run(7), halt(8), readBill(9)  

baseCommandControllerIndex 1.3.6.1.4.1.397.2.34
Sets controller index for baseCommands where relevant.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

baseCommandChannelndex 1.3.6.1.4.1.397.2.35
Sets channel index for baseCommands where relevant.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

baseConnectedToProtocol 1.3.6.1.4.1.397.2.36
Indicates the VCP state. NULL is VCP free; a returned value indicates BUSY and maps the access protocol.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER x25(1), llc2(2), null(3), epci(4), base(5), hdlc(8), qllc(9), xlan(10), ilan(11), term(12), lan(13), clus(14), mult(15), sdlc(16), ip(17), ace(18), v25b(19), cons(20), nms(21), dlc(22), map(23), tlan(24), snmp(25), nfrm(26), xfrm(27), tip(28), rout(29), ppp(30), ipx(31), tipx(32), esis(34), tsis(35), sip(36), smdx(37), dlcx(38), edlc(39), comp(40), bond(41), eses(42), rlay(43), lap(44), isdp(45), isdb(46), oem1(47), mman(48)  

baseBillingThreshold 1.3.6.1.4.1.397.2.37
Sets threshold for billing alarms - entry written to ELOG file, and trap sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

baseBillUnread 1.3.6.1.4.1.397.2.38
Number of BILLING records outstanding - to be read by SNMP manager.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

baseCurrentBill 1.3.6.1.4.1.397.2.39
Record number of current available BILLING record.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

baseBillRecordBuffer 1.3.6.1.4.1.397.2.40
The current BILLING record data.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(150)  

baseCurrentConfig 1.3.6.1.4.1.397.2.41
A decimal number from 0000 to 9999 representing the current configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

baseCommandBuffer 1.3.6.1.4.1.397.2.44
The VCP single line command string buffer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(50)  

baseCommandLength 1.3.6.1.4.1.397.2.45
The length in Hex of the single line command string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

baseEMPresent 1.3.6.1.4.1.397.2.46
Indicator of whether Environmental Monitor is present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

baseEMTempTens 1.3.6.1.4.1.397.2.47
Tens part of Environmental Monitor temperature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

baseEMTempUnits 1.3.6.1.4.1.397.2.48
Unit part of Environmental Monitor temperature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

baseEMFan1 1.3.6.1.4.1.397.2.49
Environmental Monitor Fan 1 state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ok(2), fail(3)  

baseEMFan2 1.3.6.1.4.1.397.2.50
Environmental Monitor Fan 2 state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ok(2), fail(3)  

baseEMFan3 1.3.6.1.4.1.397.2.51
Environmental Monitor Fan 3 state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ok(2), fail(3)  

baseEMVoltage 1.3.6.1.4.1.397.2.52
Environmental Monitor voltage.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

baseEMPsu1 1.3.6.1.4.1.397.2.53
Environmental Monitor PSU 1 state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ok(2), fail(3)  

baseEMPsu2 1.3.6.1.4.1.397.2.54
Environmental Monitor PSU 2 state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ok(2), fail(3)  

baseCPUUtil 1.3.6.1.4.1.397.2.55
CPU utilisation in the range 0 to 100.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlNumberConfigured 1.3.6.1.4.1.397.3.1
Total Number of Controllers Configured. The number of controllers in the MegaPAC which have been configured.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlTotalNumber 1.3.6.1.4.1.397.3.2
Total Number of Controllers. The TOTAL number of controllers in the MegaPAC including unconfigured (NULL) controllers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlStatTable 1.3.6.1.4.1.397.3.3
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CtrlStatEntry

ctrlStatEntry 1.3.6.1.4.1.397.3.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CtrlStatEntry  

ctrlStatIndex 1.3.6.1.4.1.397.3.3.1.1
Controller index. The position of this controller in relation to 'BASE'. i.e. BASE = 0 NMSC = 1 PS01 = 2 ...
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlStatName 1.3.6.1.4.1.397.3.3.1.2
Controller name. The unique 4 character name by which this controller is known.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

ctrlStatType 1.3.6.1.4.1.397.3.3.1.3
Controller Type. The type of software controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER x25(1), llc2(2), null(3), epci(4), base(5), hdlc(8), qllc(9), xlan(10), ilan(11), term(12), lan(13), clus(14), mult(15), sdlc(16), ip(17), ace(18), v25b(19), cons(20), nms(21), dlc(22), map(23), tlan(24), snmp(25), nfrm(26), xfrm(27), tip(28), rout(29), ppp(30), ipx(31), tipx(32), esis(34), tsis(35), sip(36), smdx(37), dlcx(38), edlc(39), comp(40), bond(41), eses(42), rlay(43), lap(44), isdp(45), isdb(46), oem1(47), mman(48)  

ctrlStatSubType 1.3.6.1.4.1.397.3.3.1.4
Sub Type. The serial I/O board installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), sio(2), xio(3), auto(4), gio(5), pri(9), scc(17), vio(33), rio(65)  

ctrlStatNumberChannels 1.3.6.1.4.1.397.3.3.1.5
Channel Count. The number of channels assigned to a controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlStatFirstChannelIndex 1.3.6.1.4.1.397.3.3.1.6
First Channnel. The 1st channel index number used by the controller : PPP, X.25, XFRM, NFRM VFRM, CONS, IP, TIP, IPX, TIPX, ESIS, DLC, LAN, TLAN, ILAN, XLAN SDLC, TERM, QLLC & HDLC
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlStatCRCErrors 1.3.6.1.4.1.397.3.3.1.7
CRC Errors. The number of packets received for which the checksum was not valid.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatTotalCallSetUps 1.3.6.1.4.1.397.3.3.1.8
Total Call Set ups. The total number of successful calls established on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatCurrentCalls 1.3.6.1.4.1.397.3.3.1.9
Current Calls. The number of calls currently active on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlStatDataIn 1.3.6.1.4.1.397.3.3.1.10
Data bytes In.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatDataOut 1.3.6.1.4.1.397.3.3.1.11
Data Out. The total number of data bytes transmitted on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatDataFramesIn 1.3.6.1.4.1.397.3.3.1.12
Data Frames In. The total number of data frames received on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatDataFramesOut 1.3.6.1.4.1.397.3.3.1.13
Data Frames Out. The total number of data frames transmitted on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatDataFrameRateIn 1.3.6.1.4.1.397.3.3.1.14
Data Frame Rate In. The rate that frames are arriving on this link, specified in frames per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlStatDataFrameRateOut 1.3.6.1.4.1.397.3.3.1.15
Data Frame Frate Out. The rate that frames are being transmitted on this link, specified in frames per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlStatCallsReceived 1.3.6.1.4.1.397.3.3.1.16
Calls Received. The total number of incoming call requests seen on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatCallsSent 1.3.6.1.4.1.397.3.3.1.17
Calls Sent. The total number of call requests sent out on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatClearsReceived 1.3.6.1.4.1.397.3.3.1.18
Clears Received. The total number of call clear requests received on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatRetransmissions 1.3.6.1.4.1.397.3.3.1.19
Retransmissions. The number of packets that have been transmitted more than once on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatRejects 1.3.6.1.4.1.397.3.3.1.20
Rejects. The total number of packets which have been rejected on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatState 1.3.6.1.4.1.397.3.3.1.21
State. The level 2 data state of the link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disc(1), sabm(9), data(11), blkd(13), wake(15), cls(17), frmr(19), stop(21), xidr(23), xidc(25)  

ctrlStatSubState 1.3.6.1.4.1.397.3.3.1.22
Sub State. The level 3 state of this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER norm(1), rej(5), disc(9)  

ctrlStatNoTries 1.3.6.1.4.1.397.3.3.1.23
Tries. The number of un-numbered control frames sent to try and establish the link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatOptions 1.3.6.1.4.1.397.3.3.1.24
Options The options currently configured for this link. Note, that the values returned by the MegaPAC may be additive values - representing combined combinations for the table listed e.g. poll+ext.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER norm(1), iso1984(16385), poll(32769), ext(8193), hold(4097), stat(2049), net(257), dmod(1025), dcd(513), ui(17), xidc(5), xidr(9), test(3), dtr(2), tcp(65), idle(33), poll-ext(40961), poll-dcd(33281), poll-ext-dcd(41473)  

ctrlStatLCGN 1.3.6.1.4.1.397.3.3.1.25
LCGN The logical channel group number for this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlStatResetsReceived 1.3.6.1.4.1.397.3.3.1.26
Resets Received. The total number of reset packets received on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatInterruptsReceived 1.3.6.1.4.1.397.3.3.1.27
Interupts Received. The total number of interrupt packets received on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ctrlStatOuputQueueLength 1.3.6.1.4.1.397.3.3.1.28
Output Queue Length. The number of packets queued for transmission on this link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlStatStationAddress 1.3.6.1.4.1.397.3.3.1.29
Local MAC Address The MAC Address of the MegaPAC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(12)  

ctrlStatDestinationAddress 1.3.6.1.4.1.397.3.3.1.30
Destination MAC Address. The MAC Address of the destination device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(12)  

ctrlStatEIA 1.3.6.1.4.1.397.3.3.1.31
EIA state. Displays the EIA signals currently on the link.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(8)  

ctrlStatSdlcOptions 1.3.6.1.4.1.397.3.3.1.32
SDLC Options. A range of link level options used for establishing IBM connections.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), pu4(33), wait(65), xid(129), idle(17), wait-xid(193)  

ctrlStatArpRequestRec 1.3.6.1.4.1.397.3.3.1.33
ARP Requests Received. The number of ARP requests sent to the MegaPAC
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlStatArpRequestSent 1.3.6.1.4.1.397.3.3.1.34
ARP Requests Sent. The number of ARP requests processed to the local LAN by the MegaPAC
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlStatArpResponsesRec 1.3.6.1.4.1.397.3.3.1.35
ARP Respones Received. The number of ARP responses returned to the the MegaPAC
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlStatTestType 1.3.6.1.4.1.397.3.3.1.36
Allows SNMP manager to set V54 tests; local or remote or off.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER loopModeOff(1), loopModeRemote(5), loopModeLocal(9)  

ctrlStatTestSet 1.3.6.1.4.1.397.3.3.1.37
Allows SNMP manager to apply the local/remote V54 test selection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER loopModeEstablished(1), loopModeRequested(2)  

ctrlStatTest 1.3.6.1.4.1.397.3.3.1.38
Allows SNMP manager to activate local/remote V54 test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER loopTestEstablished(1), loopTestRequested(2)  

ctrlStatLstate 1.3.6.1.4.1.397.3.3.1.39
Allows SNMP manager to read Local Loop test result.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER localLoopNoStatus(1), localLoopPass(2), localLoopFail(3)  

ctrlStatRstate 1.3.6.1.4.1.397.3.3.1.40
Allows SNMP manager to read Remote Loop test result.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER remoteLoopNoStatus(1), remoteLoopPass(2), remoteLoopFail(3)  

ctrlParamTable 1.3.6.1.4.1.397.3.4
The controller configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CtrlParamEntry

ctrlParamEntry 1.3.6.1.4.1.397.3.4.1
An individual controller configuration.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CtrlParamEntry  

ctrlParamIndex 1.3.6.1.4.1.397.3.4.1.1
Index The position of this controller in relation to 'BASE'. i.e. BASE = 0 NMSC = 1 PS01 = 2 ...
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ctrlParamName 1.3.6.1.4.1.397.3.4.1.2
Name. The unique 4 character name by which this controller is known.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4)  

ctrlParamType 1.3.6.1.4.1.397.3.4.1.3
Type. The type of controller
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER x25(1), llc2(2), null(3), epci(4), base(5), hdlc(8), qllc(9), xlan(10), ilan(11), term(12), lan(13), clus(14), mult(15), sdlc(16), ip(17), ace(18), v25b(19), cons(20), nms(21), dlc(22), map(23), tlan(24), snmp(25), nfrm(26), xfrm(27), tip(28), rout(29), ppp(30), ipx(31), tipx(32), esis(34), tsis(35), sip(36), smdx(37), dlcx(38), edlc(39), comp(40), bond(41), eses(42), rlay(43), lap(44), isdp(45), isdb(46), oem1(47), mman(48)  

ctrlParamSubType 1.3.6.1.4.1.397.3.4.1.4
Sub-Type. The link between the controller and its associated hardware type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), sio(2), xio(3), auto(4), gio(5), pri(9), scc(17), vio(33), rio(65)  

ctrlParamNoChannels 1.3.6.1.4.1.397.3.4.1.5
Number of channels. The number of logical channels configured on the controller.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4096  

ctrlParamSpeed 1.3.6.1.4.1.397.3.4.1.6
Speed. The clock speed of the interface.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bps-2000000(19), bps-1000000(18), bps-512000(17), bps-256000(16), bps-128000(15), bps-64000(14), bps-1200(13), bps-19200(12), bps-9600(11), bps-7200(10), bps-4800(9), bps-3600(8), bps-2400(7), bps-2000(6), bps-1800(5), bps-1200(4), bps-600(3), bps-300(2), ext-clock(1)  

ctrlParamInterfaceType 1.3.6.1.4.1.397.3.4.1.7
The serial interface type. Note, Only applicable to MegaCard.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER x21(2), v35(3), v24(1), epci(68)  

ctrlParamPacketSize 1.3.6.1.4.1.397.3.4.1.8
Packet Size. The maximum packet size in bytes of outgoing packets, this parameter must be less than or equal to the 'BASE' statistic 'maxPacketSize'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bytes-32(2), bytes-64(3), bytes-128(5), bytes-256(9), bytes-512(17), bytes-1024(33), tran(1)  

ctrlParamV54Modem 1.3.6.1.4.1.397.3.4.1.9
V54 Modem. Enable V54 loop back testing. Note this does not initiate loop back testing, the loop back is initiated by typing in the 'TEST' command.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(61), no(1)  

ctrlParamAddress 1.3.6.1.4.1.397.3.4.1.10
Address. The logical address designation of the controller.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dte-a(1), dce-b(2)  

ctrlParamOptions 1.3.6.1.4.1.397.3.4.1.11
Options. A range of controller options, options may be specified individually or added together.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), iso1984(16385), poll(32769), poll-net(33025), ext(8193), hold(4097), stat(2049), net(257), dmod(1025), dcd(513), ui(17), xidc(5), xidr(9), test(3), dtr(2), tcp(65), idle(33), poll-ext(40961), poll-dcd(33281), poll-ext-dcd(41473)  

ctrlParamInitFrame 1.3.6.1.4.1.397.3.4.1.12
Initial Frame.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sabm(48), sabm-pbit(64), disc(68), disc-pbit(84), none(1)  

ctrlParamT1 1.3.6.1.4.1.397.3.4.1.13
T1. Timer for retransmission of unacknowleged frames. Specified in 0.1 second units.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..80  

ctrlParamTries 1.3.6.1.4.1.397.3.4.1.14
Tries. The number of times a frame will be retransmitted before a link restart is initiated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..50  

ctrlParamKLevel2 1.3.6.1.4.1.397.3.4.1.15
KLevel 2. The level 2 window size.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

ctrlParamKLevel3 1.3.6.1.4.1.397.3.4.1.16
KLevel 3. The level 3 window size.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..127  

ctrlParamLineGroup 1.3.6.1.4.1.397.3.4.1.17
Line Group. The line group is used for load sharing. If two links have same (non-zero) line group then data may be shared between them.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

ctrlParamLCGN 1.3.6.1.4.1.397.3.4.1.18
LCGN. The logical channel group number for this link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

ctrlParamLCNOffset 1.3.6.1.4.1.397.3.4.1.19
LCN Offset. This parameter is used in conjunction with the LCGN. It's purpose is to shift the channel range by the appropriate offset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

ctrlParamAddressGroup 1.3.6.1.4.1.397.3.4.1.20
Address Group. This parameter is used in conjunction with the address group field in the x25 file to provide different addressing domains.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

ctrlParamFrameSequence 1.3.6.1.4.1.397.3.4.1.21
Frame Sequence. This parameter determines if normal or extended frame sequencing is supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER extended(15), normal(7)  

ctrlParamCallTimeOut 1.3.6.1.4.1.397.3.4.1.22
Call Time Out. The time in seconds the MegaPAC will wait to receive a call accept packet before clearing the call.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..200  

ctrlParamErrorThreshold 1.3.6.1.4.1.397.3.4.1.23
Error Threshold. The number of CRC errors that will be accepted before generating an error report.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..250  

ctrlParamLoopBarPriority 1.3.6.1.4.1.397.3.4.1.24
Loop Bar Priority. Prevents calls from looping on the same controller.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

ctrlParamExtendedCallMgmt 1.3.6.1.4.1.397.3.4.1.25
Extended Call Management. Invokes extended packet processing facilities via the MAC file.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER in(2), out(3), in-out(4), v25b(5), v25m(13), none(1)  

ctrlParamOptionalTimers 1.3.6.1.4.1.397.3.4.1.26
Optional Timers. Optional level 3 timers for clearing calls when a clear confirmation has not been received after a clear request has been sent. T13 is used if the controller is set to be a logical DCE and the timeout will be 60 seconds. T23 is used if the controller is a logical DTE and the timeout is 180 seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t13(2), t23(3), none(1)  

ctrlParamOptionalFlags 1.3.6.1.4.1.397.3.4.1.27
Optional Flags. This parameter is used to insert extra flags between frames to slow down the rate of transmission. It will only take effect on controllers with a sub-type of XIO.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..60  

ctrlParamTransportLevelType 1.3.6.1.4.1.397.3.4.1.28
Transport Level Type. Enable the ISO transport facility.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER iso(34), none(1)  

ctrlParamTransportClass 1.3.6.1.4.1.397.3.4.1.29
Transport Class. The type of transport class implemented.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER class3(49), class2(33), class0(1)  

ctrlParamDefaultWindowSize 1.3.6.1.4.1.397.3.4.1.30
Default Window Size. The initial credit limit to be used on a transport session.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

ctrlParamDisableFlowControl 1.3.6.1.4.1.397.3.4.1.31
Disable Flow Control. Enable/disable flow control on a tranport class 2 call.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(2), no(1)  

ctrlParamTSAPFormat 1.3.6.1.4.1.397.3.4.1.32
TSAP Format. Determines how the TSAP's will be treated internally by the MegaPAC. If set to text the local and remote TSAP's will be converted to form a 4 character internal resource name. If set to hex the first two hexadecimal pairs will form the resource name.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER text(2), hex(1)  

ctrlParamMaximumTPDUSize 1.3.6.1.4.1.397.3.4.1.33
Max. TPDU Size. The maximum Transport Protocol Data Unit Size.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bytes-1024(11), bytes-512(10), bytes-256(9), bytes128(8), bytes-128(1)  

ctrlParamTTRTime 1.3.6.1.4.1.397.3.4.1.34
TTR Timer. Time To Resynchronise. Specifies the time delay in seconds for the transport class three timer to resync at the initiating end.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..120  

ctrlParamTWRTime 1.3.6.1.4.1.397.3.4.1.35
TWR Timer. Time to Wait for Resynchronisation. The time delay in seconds allowed for the transport class 3 timer at the responding end to wait for resynchronisation, before clearing down the transport session.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..120  

ctrlParamDestinationAddress 1.3.6.1.4.1.397.3.4.1.36
Destination Address. The physical address of the target device.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

ctrlParamDSAP 1.3.6.1.4.1.397.3.4.1.37
DSAP. The Destination Service Access Point.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..254  

ctrlParamSSAP 1.3.6.1.4.1.397.3.4.1.38
SSAP. The Source Service Access Point.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..254  

ctrlParamSDLCOptions 1.3.6.1.4.1.397.3.4.1.39
SDLC Options. A range of link level options used for establishing IBM connections.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), pu4(33), wait(65), xid(129), idle(17), wait-xid(193)  

ctrlParamPrimaryStation 1.3.6.1.4.1.397.3.4.1.40
Primary Station. This parameter determines whether the MegaPAC will operate as a HOST primary connection (yes) or a CLUSTER secondary connection (no).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(2), no(1)  

ctrlParamIdleDetectTime 1.3.6.1.4.1.397.3.4.1.41
Idle Detect Timer. This parameter determines the time period in tenths of a second before an unacknowleged POLL/RESPONSE frame will be retransmitted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

ctrlParamPollInterval 1.3.6.1.4.1.397.3.4.1.42
Poll Interval. The time period in tenths of a second between sending POLL frames.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

ctrlParamDuplex 1.3.6.1.4.1.397.3.4.1.43
Duplex. Enables SDLC full duplex operation, half duplex operation is reserved for future use.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER full(1), half(2)  

ctrlParamTransmitDelay 1.3.6.1.4.1.397.3.4.1.44
Transmit Delay. Determines the time period in tenths of a second between the MegaPAC receiving an RR frame with the P-Bit set and the MegaPAC issuing an RR response with the F-Bit set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..20  

ctrlParamSlowPollTimer 1.3.6.1.4.1.397.3.4.1.45
Slow Poll Timer. When the controller has been defined as a primary station a slow poll rate can be specified for polling a Cluster controller that is down. This is to avoid causing delays to working Cluster controllers in a multi-point mode. The value is specified in tenths of a second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

ctrlParamMaxCallInterval 1.3.6.1.4.1.397.3.4.1.46
Max. Call Interval. When controller is configured as a primary station, a call request retry interval may be defined, so as to avoid the situation where successive call requests are continuously generated to the network. The initial call interval is 2 seconds, this interval is progressively doubled until the Maximum Call Interval (defined in minutes) is reached.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..20  

ctrlParamMaxCallCycles 1.3.6.1.4.1.397.3.4.1.47
Max. Call Cycles. This parameter is used in conjunction with the Maximum Call Interval parameter. It specifies the maximum number of call request cycles that can take effect before call requests continue at the Maximum Call Interval parameter setting. Each cycle consisting of call requests being initiated at intervals in incrementing multiples of two seconds, up to the Maximum Call Interval parameter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

ctrlParamGroupPoll 1.3.6.1.4.1.397.3.4.1.48
Group Poll. Used in SNA applications, where the specified value would generate multiple down-stream poll requests.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

ctrlParamDelayToRTSLow 1.3.6.1.4.1.397.3.4.1.49
Delay RTS Low. Specifies the number of padding characters to be inserted between the end of data transmission and the dropping of the RTS signal. Only required for synchronous operation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..256  

ctrlParamDelayToCTSHigh 1.3.6.1.4.1.397.3.4.1.50
Delay CTS High. Specifies the number of padding characters to be inserted between the dropping of RTS and the raising of CTS. Only required for synchronous operation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..256  

ctrlParamInputSyncDeletion 1.3.6.1.4.1.397.3.4.1.51
Input Sync Deletion. If set, all SYNC characters will be stripped prior to transmission. Only effective in synchronous full duplex mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ctrlParamOutputSyncInsertion 1.3.6.1.4.1.397.3.4.1.52
Output Sync Insertion. Specifies the number of SYNC characters to be transmitted prior to the start of the data block. Only effective in synchronous operation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

ctrlParamDCDFilter 1.3.6.1.4.1.397.3.4.1.53
DCD Filter. A filter delay specified in tenths of a second which prevents unwanted link restarts caused by toggling of DCD signal.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..20  

ctrlParamInhibitTimeFill 1.3.6.1.4.1.397.3.4.1.54
Inhibit Time Fill Allows the insertion of time fill frames to compensate for network delays. Effective in synchronous mode only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ctrlParamDirectedBroadcasts 1.3.6.1.4.1.397.3.4.1.55
Directed Broadcasts.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

ctrlParamDefaultLocalPrinter 1.3.6.1.4.1.397.3.4.1.56
Default Local Printer. The number of the channel which is reserved for a Screen Print server, a value of (0) disables the Screen Print facility.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..128  

ctrlParamNewLANInterface 1.3.6.1.4.1.397.3.4.1.57
New FRM Port. This controller marks the first position of a controller connection to a LAN interface. All other controllers defined as NewPhysicalInterface/ No will map to the same interface defined as NewPhysicalInterface/ Yes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(2), yes(1)  

ctrlParamNewSerialInterface 1.3.6.1.4.1.397.3.4.1.58
New FRM Port. This controller marks the first position of a controller connection to a serial interface. All other controllers defined as NewPhysicalInterface/ No will map to the same interface defined as NewPhysicalInterface/ Yes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(2), no(1)  

ctrlParamDlci 1.3.6.1.4.1.397.3.4.1.59
Defines the DLCI PVC number
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..1022  

ctrlParamMode 1.3.6.1.4.1.397.3.4.1.60
Defines a Network to Network Inteface (NNI) or User Network Interface (UNI) implementation. Where MegaPAC connects to a Frame Realy switch, this parameter just be defined as DTE i.e. a UNI, otherwise when connecting operating as a switch, NNI i.e. DCE operation must be specified. All controllers mapped to the same physical interface must be configured the same mode setting
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2), nni(129)  

ctrlParamLmi 1.3.6.1.4.1.397.3.4.1.61
Local Management Inteface (LMI). Ansi = ANSI LMI yes = T1.S1 LMI no = LMI disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ansi(129), yes(2), no(1)  

ctrlParamKeepAliveTimer 1.3.6.1.4.1.397.3.4.1.62
Only applicable if the LMI is active. Specifies in seconds the interval between keep alive messages. If this end is a DTE, this is the actual interval between Status Requests generated to the DCE. If this end is a DCE, then the timer is used simply to detect whether connection to the DTE has been lost. Note: it is the DTE which is the active partner across the LMI interface, in accordance with the LMI specification.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 2..80  

ctrlParamStatusEnquiryInterval 1.3.6.1.4.1.397.3.4.1.63
Frame Relay : Specifies how often a DTE sends a or a DCE expects a Full Status Request message. The number specified is the ratio between Status Requets messages, and Full Status Request enquiries. For example, if the value 10 is specified, and this end is a DTE, then every 10th status request would include a full status request (in the above example every 100 seconds).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

ctrlParamBandwidth 1.3.6.1.4.1.397.3.4.1.64
The sample period used in enforcing the committed information rate (CIR). The CIR expressed in terms of characters per 1/10 th second. There are two further parameters which appear directly after the BANDWIDTH/ prompt which are designed to handle bursty traffic (i.e. Bc and Be).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32767  

ctrlParamBurstCommit 1.3.6.1.4.1.397.3.4.1.65
Burst Commit, i.e. the number of characters the remote end is committed to buffering, in our case in a 1/10th of a second period
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32767  

ctrlParamBurstEligibility 1.3.6.1.4.1.397.3.4.1.66
Burst Eligibility, i.e the DLCI in question is enabled to transmit a burst beyond its committed information rate, when enabled to do so by the state of the other DLCIs. The figure given is again with respect to a 1/10th second period, and the maximum data rate when the DLCI is enabled to transmit at its burst rate is given by the equation ; Maximum data rate = CIR(1+Be/Bc) It should be noted that on DLCIs which are carrying data of a non-bursty nature (e.g voice traffic), the Be should be configured as zero (thereby telling the MegaPAC that it is carrying traffic of a non-bursty nature.) Secondly, if the Bc value is configured as zero, the MegaPAC uses a default sample period of 1 second.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32767  

chanNumberConfigured 1.3.6.1.4.1.397.4.1
Number of channels. The number of channels configured.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatTable 1.3.6.1.4.1.397.4.2
A table of channels associated with a controller.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChanStatEntry

chanStatEntry 1.3.6.1.4.1.397.4.2.1
An individual channel entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChanStatEntry  

chanStatIndex 1.3.6.1.4.1.397.4.2.1.1
Index. The position of this channel in the controller channel Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatName 1.3.6.1.4.1.397.4.2.1.2
Name. A user defined name for routing calls to this channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

chanStatControllerIndex 1.3.6.1.4.1.397.4.2.1.3
Controller Index. The index to the controller that this channel operates within.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatNameCtrlName 1.3.6.1.4.1.397.4.2.1.4
Controller Name. The controller NAME supporting this channel
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

chanStatConnectedToChannelIndex 1.3.6.1.4.1.397.4.2.1.5
Connected to Index. The INDEX of the CHANNEL that this channel is connected to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatState 1.3.6.1.4.1.397.4.2.1.6
State. The current Status of the channel, the status may be one or a combination of the following: disc Disconnected. emul Channel in Terminal Emulation mode. emul Channel in Terminal Emulation mode. post Processing data before forwarding e.g. LF insert in async. busy Temporarily unavailable. call Outgoing channel making call. data Data transfer, call in progress. wake Outgoing channel transmitting. setup Incoming channel waiting outgoing channel call setup. rout Incoming channel waiting assignment of outgoing channel. addr Incoming channel waiting resource selection. name Incoming channel is processing a users password. look Incoming channel is looking-up a users password name. serv Service selection mode awaiting resource code NAME. pass Incoming channel is processing a users password. rung Ring Indicator MUX PORT only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disc(1), emul(73), emul(69), post(57), busy(49), call(45), data(41), wake(37), setup(33), rout(29), addr(25), name(21), look(17), serv(13), pass(9), rung(5)  

chanStatSessionStatus 1.3.6.1.4.1.397.4.2.1.7
Session Status. The Status of the channel during a call session, the status may be one or a combination of the following: State Description CALL Call Originator. DRI Flow controlling input. DRO Flow controlling on output. TRAN Presentation service not involved in call set-up. QUEU Queued to selected resource. STAT Awaiting queue status information. PAD In PAD Recall mode. DISC Data buffers draining before clearing call.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), tran(2), dri(3), dro(5), call(9), pad(17), queu(33), stat(65), call-tran(10), call-tran-dri(13), disc(129)  

chanStatEIA 1.3.6.1.4.1.397.4.2.1.8
EIA Displays the status of the V24/V28 signals on term or muxport links, or call status on X.25 links. The down state indicates that level 2 is inactive.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), dcd(2), ring(3), x28(5), rej(9), iso(17), tcal(33), closed(65), down(129)  

chanStatTotalFramesIn 1.3.6.1.4.1.397.4.2.1.9
Total Frames In. The total number of frames received on this channel since it entered Data State.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatTotalFramesOut 1.3.6.1.4.1.397.4.2.1.10
Total Frames out. The total number of frames transmitted on this channel since it entered Data State.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatTotalCharsIn 1.3.6.1.4.1.397.4.2.1.11
Total Characters In. The total number of characters received on this channel since it entered Data State.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatTotalCharsOut 1.3.6.1.4.1.397.4.2.1.12
Total Characters Out. The total number of characters transmitted on this channel since it entered Data State.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatTxWindow 1.3.6.1.4.1.397.4.2.1.13
Tx Window. The Level 3 Transmit Window size.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatRxWindow 1.3.6.1.4.1.397.4.2.1.14
Rx Window. The Level 3 Receive Window size.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatTxSize 1.3.6.1.4.1.397.4.2.1.15
Tx Size. The maximum size for outgoing packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatRxSize 1.3.6.1.4.1.397.4.2.1.16
Rx Size. The maximum acceptable size for incoming packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatCause 1.3.6.1.4.1.397.4.2.1.17
Cause. The value of the cause code in the last Clear Packet received or transmitted (decimal).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatDiagnostic 1.3.6.1.4.1.397.4.2.1.18
Diagnostic. The value of the diagnostic code in the last Clear Packet received or transmitted (decimal).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatResetCause 1.3.6.1.4.1.397.4.2.1.19
Reset Cause. The value of the last reset code in the last RESET packet transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatResetDiagnostic 1.3.6.1.4.1.397.4.2.1.20
Reset Diagnostic. The value of the last diagnostic code in the last RESET packet transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatResetCauseReceived 1.3.6.1.4.1.397.4.2.1.21
Reset Cause Received. The value of the last reset code in the last RESET packet received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatResetDiagReceived 1.3.6.1.4.1.397.4.2.1.22
Reset Diagnostic Received. The value of the last diagnostic code in the last RESET packet received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatLevel3State 1.3.6.1.4.1.397.4.2.1.23
Level 3 State. The level 3 status of the channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disc(1), rest(3), call(5), data(7), cls(9), clr(11), reset(13)  

chanStatCallPriority 1.3.6.1.4.1.397.4.2.1.24
Call Priority. Call and Resource priorities are used primarily for providing alternate routing. For a call to succeed the Call Priority on the incoming channel must be greater than or equal to the Resource Priority on the outgoing channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatResourcePriority 1.3.6.1.4.1.397.4.2.1.25
Resource Priority See chanCallPriority above.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatPadEnable 1.3.6.1.4.1.397.4.2.1.26
PAD Enable. The value of this statistic reflects the setting as configured on the channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disable(1), enable(2), rev(3), enable-rev(4), prof(5), enable-prof(6), mask(17), enable-mask(18), x28(34)  

chanStatPortMatch 1.3.6.1.4.1.397.4.2.1.27
Port Match. The TCP port that is connected
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(1), srce(2), dest(129), wild(137)  

chanStatPrimaryStation 1.3.6.1.4.1.397.4.2.1.28
Primary Station. Determines whether the MegaPAC port is functioning as a Primary or Secondary SDLC station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

chanStatSDLCState 1.3.6.1.4.1.397.4.2.1.29
SDLC State. The State of the SDLC connection, may be one of the following: State Description ACTIVE The SNRM and UA commands have been sent successfully. If primary, the P-Bit has not been sent (i.e. has not been polled). If secondary, the P-Bit has not been received (has got F-Bit and not been polled again). DISC Primary station only. Either a 'STOP' command has been issued for the port, or a QDISC command has been received from the network. The MegaPAC will be sending an SDLC DISC command with the P-Bit set. POLL If primary, the MegaPAC has sent a frame with the P-Bit (has polled). If secondary, the MegaPAC has received the P-Bit (has been polled). SNRM Only for primary stations. The MegaPAC has sent a SNRM, but has not received a UA.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), snrm(3), active(5), poll(7), disc(9)  

chanStatQLLCState 1.3.6.1.4.1.397.4.2.1.30
QLLC State. The State of the QLLC connection, may be one of the following: State Description CLSD The MegaPAC has received a QDISC and sent a QUA on the network. This sets the DISC state on the SDLC port. CLSI The MegaPAC has sent a QDISC and is waiting for a QUA. FRMR The MegaPAC has received a QFRMR from the network. INOP The SVC is down. OPEN The VC is running. QSM and QUA have been sent and received. OPNI The MegaPAC has sent a QSM and is awaiting a QUA.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inop(1), clsd(5), openi(9), frmr(13), clsi(17), open(21)  

chanStatSDLCTransmitState 1.3.6.1.4.1.397.4.2.1.31
SDLC Transmit State. May be one of the following: State Description NORM The MegaPAC is allowed to transmit data. NULL The MegaPAC is not allowed to transmit data. RNR The MegaPAC has received an RNR. RTRY The MegaPAC is in the retransmission state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), norm(3), rtry(7), rnr(11)  

chanStatPolls 1.3.6.1.4.1.397.4.2.1.32
Polls. The quantity of polls that have occured since the link was established
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatStationAddress 1.3.6.1.4.1.397.4.2.1.33
Station Address. The IBM PU poll address
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatXIDIdentification 1.3.6.1.4.1.397.4.2.1.34
XID Identification. This field contains the first 64 bytes of the XID that has been used.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

chanStatTries 1.3.6.1.4.1.397.4.2.1.35
Tries. The number of times the current command has been transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatWindow 1.3.6.1.4.1.397.4.2.1.36
KLevel 2. The level 2 window size.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatLUActive 1.3.6.1.4.1.397.4.2.1.37
LU Active. If set to YES then the MegaPAC Logical Unit has responded positively to an ACTLU command. If set to NO the MegaPAC has either not received or has responded negatively to an ACTLU command.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

chanStatBindActive 1.3.6.1.4.1.397.4.2.1.38
Bind Active. If set to YES then the MegaPAC Logical Unit has responded positively to a BIND command. If set to NO the MegaPAC has either not received or has responded negatively to a BIND command.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

chanStatLUType 1.3.6.1.4.1.397.4.2.1.39
LU Type. The Session type taken from the BIND command. It may be one of the following: Session Type Description 0 User defined applications. 1 Printer. 2 Full Screen 3270 applications. 3 Older type printers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

chanStatBreaksReceived 1.3.6.1.4.1.397.4.2.1.40
Breaks Rx The number of Break characters received from the terminal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatFramingErrors 1.3.6.1.4.1.397.4.2.1.41
Framing Errors. The number of characters received with no stop bit appended. The MegaPAC substitutes a '#' character in place of each framing error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatInputOverruns 1.3.6.1.4.1.397.4.2.1.42
Input Overruns. The number of times that data has been discarded due to a lack of receive buffers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatParityErrors 1.3.6.1.4.1.397.4.2.1.43
TParity Errors. he number of parity errors received on this channel.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatTerminalType 1.3.6.1.4.1.397.4.2.1.44
Terminal Type. The type of emulation to be applied to the TERM controller, it may be one or more of the following: Type comment ASYN ASCII data support SYNC Bi-sync data support MINI Minitel terminal support HP H.P ENQ / ACK async protocol support X28 X28 command syntax (English) X28F X28 command syntax (French) ANSI Async ASCII Terminal support VPAD Viewdata PAD Emulation support MTRM MegaTerm PC Emulation support BUF Used for Buffer PVC call set-ups TPAD ACAB30 transaction card terminal support VT22 Async VT220Terminal support
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER async(2), sync(3), hp(225), x28(209), x28f(999), ansi(177), ext-ansi(161), vpad(129), mtrm(113), slip(97), buf(81), tpad(65), vt220(41)  

chanStatCircuitType 1.3.6.1.4.1.397.4.2.1.45
Circuit Type. The type of circuit used on this channel, it may be one or more of the following:
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER call(2), call-stat(66), call-pvc(10), call-pvc-stat(74), out(17), out-stat(81), out-pvc(25), out-pvc-stat(89), osi-call(6), osi-call-stat(70), osi-call-pvc(14), osi-call-pvc-stat(78), osi-out(21), osi-out-stat(85), osi-out-pvc(29), osi-out-pvc-stat(93), osi-call-svc(38), osi-call-svc-stat(102), osi-out-svc(53), osi-out-svc-stat(117), svc(33), svc-stat(97), queue(4)  

chanStatOptions 1.3.6.1.4.1.397.4.2.1.46
The option(s) which have been envoked on this channel, one or more of:
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), rts(2), idle(3), busy(5), hold(9), nbrk(17), arps(65), iso(129), pass(257), bill(513), msgs(1025), gate(2049), name(4097), talk(8193), x28(16385), supr(32769)  

chanStatBuffers 1.3.6.1.4.1.397.4.2.1.47
Buffers. The number of data buffers to be used as a threshold value before flow control to the terminal is invoked.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatDiscMode 1.3.6.1.4.1.397.4.2.1.48
Disc mode. Specifies the call disconnect character that may be applied having established a route via the presentation service.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatMenuNumber 1.3.6.1.4.1.397.4.2.1.49
Menu Number. Specifies which menu will be displayed to the user by the presentation service.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatHelpNumber 1.3.6.1.4.1.397.4.2.1.50
Help Number. Specifies which help menu will be displayed to the user by the presentation service.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatNewsNumber 1.3.6.1.4.1.397.4.2.1.51
News Number. The Menu number that will be displayed if an outgoing resource is unavailable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatPadRecall 1.3.6.1.4.1.397.4.2.1.52
Pad Recall. This parameter allows the user to escape from the data transfer state to the PAD command state. The permitted values are: 0 No PAD recall 1 Escape character is ^P 2 - 126 The decimal value specified is the escape character
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatEcho 1.3.6.1.4.1.397.4.2.1.53
Echo. Determines whether 'echo' is enabled or disabled. If set to controlled, the echo facility is controlled by the operator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enable(2), disable(1)  

chanStatDataForwarding 1.3.6.1.4.1.397.4.2.1.54
Data Forwarding. This parameter controls which character or characters cause the accumulated data to be forwarded. The possible values may be added together to forward on one of a number of conditions. The allowable values are: 0 Forward only on buffer full. 128 Forward on graphics characters. 64 Forward on all characters in columns 0 and 1 of the International Alphabet No. 5. 1 Forward on A-Z, a-z and 0-9. 2 Forward on Carriage Return. 4 Forward on ESC, BEL, ENQ, ACK. 8 Forward on DEL, CAN, DC2. 16 Forward on EXT, EOT. 32 Forward on HT, LF, VT, FF.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatDelay 1.3.6.1.4.1.397.4.2.1.55
Delay. Specifies the idle time in tenths of a second, allowable between successive characters before the accumulated data is forwarded. A value of 0 disables the timeout facility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatDRI 1.3.6.1.4.1.397.4.2.1.56
DRI. Flow control of terminal by the MegaPAC. Valid settings are: enabled MegaPAC flow controls terminal using XON/XOFF. cts MegaPAC flow controls terminal using CTS. init+enable MegaPAC sends XON automatically on initialisation. disable No flow control.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), rts(33), cts(129), init-enable(65), disabled(1)  

chanStatPadSignals 1.3.6.1.4.1.397.4.2.1.57
Pad Signals. Enable X.28 prompts and/or messages to be displayed on the users terminal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enable(2), disable(1)  

chanStatBreak 1.3.6.1.4.1.397.4.2.1.58
Break. The Action the MegaPAC will take on receipt of a Break Signal. The valid values are: 0 When the MegaPAC receives a Break Signal from the terminal no action is taken. 1 When the MegaPAC receives a Break Signal from the terminal it will transmit an INTERRUPT packet. 2 When the MegaPAC receives a Break Signal from the terminal it will transmit an RESET packet. 5 When the MegaPAC receives a Break Signal from the terminal it will transmit an INTERRUPT packet and an indication of Break PAD message. 8 When the MegaPAC receives a Break Signal from the terminal it will escape from data transfer state. 21 When the MegaPAC receives a Break Signal from the terminal it will transmit an INTERRUPT packet and an indication of Break PAD message, while setting (X3) parameter (8) to the value 1 (discard any data received from the network).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatPadding 1.3.6.1.4.1.397.4.2.1.59
Padding. The number of NULL characters inserted after a carriage return.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatFold 1.3.6.1.4.1.397.4.2.1.60
Fold The number of characters output before line folding occurs. Setting to 0 disables line folding.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatDRO 1.3.6.1.4.1.397.4.2.1.61
Data Restraint Out.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), cts(129), init-enable(65), disabled(1)  

chanStatLFI 1.3.6.1.4.1.397.4.2.1.62
LFI. This parameter controls linefeed insertion after a carriage return. The valid seetings are: 0 Line feed insertion disabled. 1 A linefeed is inserted after a carriage return, in the data forwarded to the terminal. 4 A linefeed is sent to the terminal after echo of a carriage return to the terminal. 5 As defined by values 1 + 4. 6 Linefeed inserted after carriage return from terminal and each carriage return echoed to the terminal. 7 As defined by values 1 + 6.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatLFPad 1.3.6.1.4.1.397.4.2.1.63
LFPad. The number of NULL padding characters sent to a device following a linefeed character.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatEdit 1.3.6.1.4.1.397.4.2.1.64
Edit. Controls editing of text in data transfer state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

chanStatCharDel 1.3.6.1.4.1.397.4.2.1.65
Char Del. The keystroke used for deleting a character.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatBufferDel 1.3.6.1.4.1.397.4.2.1.66
Buffer Del. The keystroke used for deleting the buffer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatDisp 1.3.6.1.4.1.397.4.2.1.67
Disp The keystroke used to redisplay the data in the buffer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatEditServiceSignals 1.3.6.1.4.1.397.4.2.1.68
Edit Service Signals. This parameter enables the user to edit the PAD service signals (echoing). The valid settings are: 0 No editing PAD service signals are echoed. 1 A '\' will be echoed for each character deleted. 2 A 'BS' character will be echoed for each character deleted. 8 and 32-126 Specifies the decimal value of the ASCII character to be echoed for each character deleted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatEchoMask 1.3.6.1.4.1.397.4.2.1.69
Echo Mask. This parameter controls the characters which should not be echoed. The valid settings are: 0 All characters should be echoed to the terminal. 1 do not echo carriage return. 2 do not echo linefeed. 4 do not echo VT, HT and FF characters. 8 do not echo BEL and BS character. 16 do not echo ESC and ENQ. 32 do not echo ACK, NAK, STX, SOH, EOT, ETB or ETX. 64 do not echo editing characters as defined by parameters 16, 17 and 18. 128 do not echo other control characters and DEL.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatParityTreatment 1.3.6.1.4.1.397.4.2.1.70
Parity Treatment. Determines the parity generation and checking performed valid settings are: 0 No parity generation or checking. 1 Check parity. 2 Generate parity. 3 Check and generate parity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatPageWait 1.3.6.1.4.1.397.4.2.1.71
PageWait. Specifies the number of lines to be transmitted, after which the MegaPAC will wait until instructed by the user to continue sending data (by entering Q). A value of 0 disables the page wait facility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatForce 1.3.6.1.4.1.397.4.2.1.72
Forward Char. The ASCII character which will force data forwarding, 0 disables forced data forwarding.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatBreakChar 1.3.6.1.4.1.397.4.2.1.73
Break Char. The ASCII character in decimal which is used to simulate a BREAK signal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatNetworkParity 1.3.6.1.4.1.397.4.2.1.74
Network Parity. With the Terminal type set to ASYN+X28, the parity can be forced onto the network side by selecting the approriate value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER even(1), odd(2), mark(4), space(8), none(5)  

chanStatEscapeDelay 1.3.6.1.4.1.397.4.2.1.75
Escape Delay. Specifies the time in tenths of a second, that after receiving an ESC character, all characters are buffered before being forwarded. During this time the ECHO facility is turned off, and is only restored when the delay timer has expired.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatDestTsap 1.3.6.1.4.1.397.4.2.1.76
Destination TSAP The destination Transport Service Access Point.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

chanStatTransportLevelState 1.3.6.1.4.1.397.4.2.1.77
Transport Level State. Transport Class 4 session statistics
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disc(1), call(3), init(5), data(7), cls(9), clr(11)  

chanStatLinkState 1.3.6.1.4.1.397.4.2.1.78
Link State. The current state of the Link Control Protocol
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER open(15), acks(13), ackr(11), reqs(9), stpi(7), clsi(5), stop(3), clos(1)  

chanStatProtocolState 1.3.6.1.4.1.397.4.2.1.79
Protocol State. The current state of the Protocol Control Protocol
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER open(15), acks(13), ackr(11), reqs(9), stpi(7), clsi(5), stop(3), clos(1)  

chanStatProtocol 1.3.6.1.4.1.397.4.2.1.80
Protocol Displays the protocol configured for the channel
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ip(32802), ipx(32812)  

chanStatIdentity 1.3.6.1.4.1.397.4.2.1.81
Identity. The current value of the IDENTITY field being put into the Link Control Protocol or Protocol Control Protocol commands.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanStatDlciRxDe 1.3.6.1.4.1.397.4.2.1.82
DLCI RX Count. The total number of Frames with the DE bit set received on this channel since it entered Data State.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatDlciTxDe 1.3.6.1.4.1.397.4.2.1.83
DLCI TX Count. The total number of Frames with the DE bit set transmitted on this channel since it entered Data State.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatDlciRxFecn 1.3.6.1.4.1.397.4.2.1.84
DLCI RX Fecn Count. The total number of Fecns (Forward Explicit Congestion Notification) received on this channel since active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatDlciTxFecn 1.3.6.1.4.1.397.4.2.1.85
DLCI TX Fecn Count. The total number of Fecns (Forward Explicit Congestion Notification) transmitted on this channel since active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatDlciRxBecn 1.3.6.1.4.1.397.4.2.1.86
DLCI RX Becn Count. The total number of Becns (Backwards Explicit Congestion Notification) received on this channel since active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatDlciTxBecn 1.3.6.1.4.1.397.4.2.1.87
DLCI TX Becn Count. The total number of Becns (Backwards Explicit Congestion Notification) transmitted on this channel since active.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

chanStatConnectedToControllerIndex 1.3.6.1.4.1.397.4.2.1.88
Connected to Index. The INDEX of the CONTROLLER that this channel is connected to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanParamTable 1.3.6.1.4.1.397.4.3
A table of channels associated with this Level 2 controller.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChanParamEntry

chanParamEntry 1.3.6.1.4.1.397.4.3.1
An individual Channel.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ChanParamEntry  

chanParamIndex 1.3.6.1.4.1.397.4.3.1.1
Index. The position of this channel in the controller channel Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

chanParamName 1.3.6.1.4.1.397.4.3.1.2
Name. A user defined name for routing calls to this channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4)  

chanParamDRCMask 1.3.6.1.4.1.397.4.3.1.3
DRC Mask. A four character string used to force expicit routing to the named resource.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4)  

chanParamTerminalType 1.3.6.1.4.1.397.4.3.1.4
Terminal Type. If the channel is to perform terminal emulation, then the setting defined will be specific to the users terminal envoking emulation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER async(2), sync(3), hp(225), x28(209), x28f(999), ansi(177), ext-ansi(161), vpad(129), mtrm(113), slip(97), buf(81), tpad(65), vt220(41)  

chanParamCircuitType 1.3.6.1.4.1.397.4.3.1.5
Circuit Type. The type of circuit used on this channel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER call(2), call-stat(66), call-pvc(10), call-pvc-stat(74), out(17), out-stat(81), out-pvc(25), out-pvc-stat(89), osi-call(6), osi-call-stat(70), osi-call-pvc(14), osi-call-pvc-stat(78), osi-out(21), osi-out-stat(85), osi-out-pvc(29), osi-out-pvc-stat(93), osi-call-svc(38), osi-call-svc-stat(102), osi-out-svc(53), osi-out-svc-stat(117), svc(33), svc-stat(97), queue(4)  

chanParamOptions 1.3.6.1.4.1.397.4.3.1.6
Options. A range of channel options, these options may be specified individually or added together.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), msgs(1025), msgs-name(5121), msgs-name-talk(13313), msgs-pass(1281), msgs-pass-gate(3329), msgs-name-pass(5377), msgs-name-pass-talk(13569), msgs-name-pass-talk-gate(15617), pass(257), bill(513), gate(2049), name(4097), x28(16385), talk(8193), supr(32769), arps(65), diag(33), iso(129), rts(2), idle(3), busy(5), hold(9), nbrk(17)  

chanParamBuffers 1.3.6.1.4.1.397.4.3.1.7
Buffers. The number of system buffers allocated to this channel for incoming calls.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..240  

chanParamDiscMode 1.3.6.1.4.1.397.4.3.1.8
DISC Mode. The number of the character in decimal which forces disconnection of the call.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32  

chanParamMenuNumber 1.3.6.1.4.1.397.4.3.1.9
Menu Number. Specifies which menu will be displayed to the user by the presentation service
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32  

chanParamHelpNumber 1.3.6.1.4.1.397.4.3.1.10
Help Number. Specifies which help screen will be displayed to the user by the presentation service.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32  

chanParamNewsNumber 1.3.6.1.4.1.397.4.3.1.11
News Number. The number of the menu which will be displayed if an outgoing channel is unavailable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32  

chanParamCallPriority 1.3.6.1.4.1.397.4.3.1.12
Call Priority. Call and Resource priorities are used primarily for providing alternate routing. For a call to succeed the Call Priority on the incoming channel must be greater than or equal to the Resource Priority on the outgoing channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

chanParamResourcePriority 1.3.6.1.4.1.397.4.3.1.13
Resource Priority. Call and Resource priorities are used primarily for providing alternate routing. For a call to succeed the Call Priority on the incoming channel must be greater than or equal to the Resource Priority on the outgoing channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

chanParamPadEnable 1.3.6.1.4.1.397.4.3.1.14
Pad Enable. The effect of the PAD Enable parameters are as follows: enable PAD services enabled. The logical channel will respond to X.29 packets. enable-rev REVerse PAD enabled. When a call is established to this channel, the MegaPAC will generate an X.29 qualified data packet back to the caller, containing the X.3 operating values specified in the channel's configuration. enable-prof The X.3 profile settings for the channel will be derived by referencing the logical channel's NAME/ parameter to the NAME/ field in the PROF file. The X.3 settings as contained in the PROF file record are then loaded onto the channel.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2), rev(3), enable-rev(4), prof(5), enable-prof(6), mask(17), enable-mask(18), x28(34)  

chanParamPadRecall 1.3.6.1.4.1.397.4.3.1.15
Pad Recall (1). This parameter allows the user to escape from the data transfer state to the PAD command state. The permitted values are: 0 No PAD recall 1 Escape character is ^P 2 - 126 The decimal value specified is the escape character
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..126  

chanParamEcho 1.3.6.1.4.1.397.4.3.1.16
Echo. Determines whether 'echo' is enabled or disabled. If set to controlled, the echo facility is controlled by the operator.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(2), disable(1)  

chanParamDataForwarding 1.3.6.1.4.1.397.4.3.1.17
Data Forwarding. This parameter controls which character or characters cause the accumulated data to be forwarded. The possible values may be added together to forward on one of a number of conditions. The allowable values are: 0 Forward only on buffer full. 128 Forward on graphics characters. 64 Forward on all characters in columns 0 and 1 of the International Alphabet No. 5. 1 Forward on A-Z, a-z and 0-9. 2 Forward on Carriage Return. 4 Forward on ESC, BEL, ENQ, ACK. 8 Forward on DEL, CAN, DC2. 16 Forward on EXT, EOT. 32 Forward on HT, LF, VT, FF.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

chanParamDelay 1.3.6.1.4.1.397.4.3.1.18
Delay. Specifies the idle time in tenths of a second, allowable between successive characters before the accumulated data is forwarded. A value of 0 disables the timeout facility.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

chanParamDRI 1.3.6.1.4.1.397.4.3.1.19
DRI. Flow control of terminal by the MegaPAC. Valid settings are: enabled MegaPAC flow controls terminal using XON/XOFF. cts MegaPAC flow controls terminal using CTS. init+enable MegaPAC sends XON automatically on initialisation. disable No flow control.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(2), rts(33), cts(129), init-enable(65), disabled(1)  

chanParamPadSignals 1.3.6.1.4.1.397.4.3.1.20
Pad Signals. Enable X.28 prompts and/or messages to be displayed on the users terminal.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(2), disable(1)  

chanParamBreak 1.3.6.1.4.1.397.4.3.1.21
Break. The Action the MegaPAC will take on receipt of a Break Signal. The valid values are: 0 When the MegaPAC receives a Break Signal from the terminal no action is taken. 1 When the MegaPAC receives a Break Signal from the terminal it will transmit an INTERRUPT packet. 2 When the MegaPAC receives a Break Signal from the terminal it will transmit an RESET packet. 5 When the MegaPAC receives a Break Signal from the terminal it will transmit an INTERRUPT packet and an indication of Break PAD message. 8 When the MegaPAC receives a Break Signal from the terminal it will escape from data transfer state. 21 When the MegaPAC receives a Break Signal from the terminal it will transmit an INTERRUPT packet and an indication of Break PAD message, while setting (X3) parameter (8) to the value 1 (discard any data received from the network).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

chanParamPadding 1.3.6.1.4.1.397.4.3.1.22
Padding. The number of NULL characters inserted after a carriage return.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

chanParamFold 1.3.6.1.4.1.397.4.3.1.23
Fold. The number of characters output before line folding occurs. Setting to 0 disables line folding.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

chanParamDRO 1.3.6.1.4.1.397.4.3.1.24
Data Restraint Out.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(2), cts(129), init-enable(65), disabled(1)  

chanParamLFI 1.3.6.1.4.1.397.4.3.1.25
LFI. This parameter controls linefeed insertion after a carriage return. The valid settings are: 0 Line feed insertion disabled. 1 A linefeed is inserted after a carriage return, in the data forwarded to the terminal. 4 A linefeed is sent to the terminal after echo of a carriage return to the terminal. 5 As defined by values 1 + 4. 6 Linefeed inserted after carriage return from terminal and each carriage return echoed to the terminal. 7 As defined by values 1 + 6.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

chanParamLFPad 1.3.6.1.4.1.397.4.3.1.26
LFPad. The number of NULL padding characters sent to a device following a linefeed character.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..7  

chanParamEdit 1.3.6.1.4.1.397.4.3.1.27
Edit. Controls editing of text in data transfer state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(2), disable(1)  

chanParamCharDel 1.3.6.1.4.1.397.4.3.1.28
Char Delete. The keystroke used for deleting a character.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..128  

chanParamBufferDel 1.3.6.1.4.1.397.4.3.1.29
Buffer Delete. The keystroke used for deleting the buffer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

chanParamDisp 1.3.6.1.4.1.397.4.3.1.30
Disp. The keystroke used to redisplay the data in the buffer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

chanParamEditServiceSignals 1.3.6.1.4.1.397.4.3.1.31
Edit Service Signals. This parameter enables the user to edit the PAD service signals (echoing). The valid settings are: 0 No editing PAD service signals are echoed. 1 A '\' will be echoed for each character deleted. 2 A 'BS' character will be echoed for each character deleted. 8 and 32-126 Specifies the decimal value of the ASCII character to be echoed for each character deleted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..126  

chanParamEchoMask 1.3.6.1.4.1.397.4.3.1.32
Echo Mask. This parameter controls the characters which should not be echoed. The valid settings are: 0 All characters should be echoed to the terminal. 1 do not echo carriage return. 2 do not echo linefeed. 4 do not echo VT, HT and FF characters. 8 do not echo BEL and BS character. 16 do not echo ESC and ENQ. 32 do not echo ACK, NAK, STX, SOH, EOT, ETB or ETX. 64 do not echo editing characters as defined by parameters 16, 17 and 18. 128 do not echo other control characters and DEL.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

chanParamParityTreatment 1.3.6.1.4.1.397.4.3.1.33
Parity Treatment. Determines the parity generation and checking performed valid settings are: 0 No parity generation or checking. 1 Check parity. 2 Generate parity. 3 Check and generate parity.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3  

chanParamPageWait 1.3.6.1.4.1.397.4.3.1.34
Page Wait. Specifies the number of lines to be transmitted, after which the MegaPAC will wait until instructed by the user to continue sending data (by entering Q). A value of 0 disables the page wait facility.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

chanParamForce 1.3.6.1.4.1.397.4.3.1.35
Force. The ASCII character which will force data forwarding, 0 disables forced data forwarding.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

chanParamBreakChar 1.3.6.1.4.1.397.4.3.1.36
Break Character. The ASCII character in decimal which is used to simulate a BREAK signal.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32  

chanParamNetworkParity 1.3.6.1.4.1.397.4.3.1.37
Network Parity. With the Terminal type set to ASYN+X28, the parity can be forced onto the network side by selecting the approriate value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER even(1), odd(2), mark(4), space(8), none(5)  

chanParamEscapeDelay 1.3.6.1.4.1.397.4.3.1.38
Escape Delay. Specifies the time in tenths of a second, that after receiving an ESC character, all characters are buffered before being forwarded. During this time the ECHO facility is turned off, and is only restored when the delay timer has expired.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

chanParamStationAddress 1.3.6.1.4.1.397.4.3.1.39
Station Address. Physical Unit Address of the Cluster Controller.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

chanParamProvideXID 1.3.6.1.4.1.397.4.3.1.40
Provide XID.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

chanParamMode 1.3.6.1.4.1.397.4.3.1.41
Mode. This parameter provides a number of additional connection facilities for channels on virtual controllers.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), path(2), push(3), pull(5), stop(9), auto(17), auto-pull-path-push-stop(32), sym(33), data(65), wait(81), hub(97), resp(129), sat(193)  

chanParamPortMatch 1.3.6.1.4.1.397.4.3.1.42
Port Match. This parameter optionally allows the Source and Destination ports to be used in conjunction with the IP address for routing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), source(2), destination(129), wild(137)  

chanParamReverseTelnetPort 1.3.6.1.4.1.397.4.3.1.43
Reverse Telnet Port. The port number which will respond to TELNET open requests. The default value for TELNET ports is '23'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32767  

chanParamBroadcastFilterTimer 1.3.6.1.4.1.397.4.3.1.44
Broadcast Filter Timer.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..12000  

chanParamInhibitLearning 1.3.6.1.4.1.397.4.3.1.45
Inhibit Learning. This parameter determines whether the 'bridge' will work in Directed or Learning mode. If InhibitLearning is set to 'Yes' then the bridge will only forward frames whose addresses are fixed in the forwarding table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

chanParamRetainSession 1.3.6.1.4.1.397.4.3.1.46
Retain Session. This parameter determines if and how a session will be cleared down when the call is cleared. The parameter is only applicable to channels (2) to (n). If set to NOTIFY or NO the session will be cleared when the call disconnects , NOTIFY will cause a NOTIFY RU to be sent indicating the disconnection. If this parameter is set to YES then the session will be retained on channel disconnection, this is used to provide a hot key switching facility.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notify(1), yes(2), no(3)  

chanParamPrinterType 1.3.6.1.4.1.397.4.3.1.47
Printer Type. If set to IBM the logical channel will act as an appication system printer, otherwise it operates in screen emulation mode. Only applicable to channels (2) to (n).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ibm(1), none(2)  

chanParamScreenPrinter 1.3.6.1.4.1.397.4.3.1.48
Screen Printer. If set to YES, screen printer requests are to be processed and sent to this LU address (in this mode, the terminal attaching to this channel MUST have a printer attached). If set to NO, screen printing is supported via the LOCAL PRINTER or the DEFAULT LOCAL PRINTER parameters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

chanParamLocalPrinter 1.3.6.1.4.1.397.4.3.1.49
Local Printer. This parameter specifies the channel to which screen printing should be directed. It takes precedence over the value defined by the DEFAULT LOCAL PRINTER at controller level. This parameter may only be applied to channels (2) to (n).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..128  

chanParamInterlockBind 1.3.6.1.4.1.397.4.3.1.50
Interlock Bind. This parameter is only applicable to channels (2) to (n). When set to YES, an UNBIND request will be sent to the host upon disconnecting. Note: when used in cojunction with a 4 character DRC mask, this setting will invoke a call set-up when a BIND is received. This setting is often used when sending a file transfer accross a Public Network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

chanParamRedirectPrintTo 1.3.6.1.4.1.397.4.3.1.51
Redirect Printer To. This parameter is only applicable to channels (2) to (n). If set to (0), then no redirection takes place. Otherwise, LU type 1 session data is output to the nominated logical channel, each block being preceeded by the escape sequence to switch to the auxiliary port, and followed by the sequence to switch it back to the screen again. This is useful in several environments, Foe example, using two LU channels it enables a terminal user to interact with the Host, and receive Host system prints at the same terminal (supporting a printer).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..128  

chanParamLUBase 1.3.6.1.4.1.397.4.3.1.52
First LU defined by up-stream host.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

chanParamLUOffset 1.3.6.1.4.1.397.4.3.1.53
LU Offset.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

chanParamLUTotal 1.3.6.1.4.1.397.4.3.1.54
Total number of LUs to be allocated to down- stream PU's.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

chanParamDlciBase 1.3.6.1.4.1.397.4.3.1.55
The channel DLCI address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1023  

chanParamDlciAdjacentBase 1.3.6.1.4.1.397.4.3.1.56
The DLCI number on the cross connected port in the MegaPAC used when groups of channels are being switched across the MegaPAC. Used in conjunction with the DRC mask.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1023  

chanParamDlciPriority 1.3.6.1.4.1.397.4.3.1.57
A value from 0 to 32 indicating the relative priority of this DLCI to the other data streams on this trunk, i.e. other DLCIs. The higher the value the higher the priority.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32  

chanParamDlciATM 1.3.6.1.4.1.397.4.3.1.58
Determines whether fragmentation should be implemented on frames on this link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), all(129)  

chanParamDlciCir 1.3.6.1.4.1.397.4.3.1.59
The committed information rate for this DLCI - the units are in 80bits/sec
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32767  

chanParamDlciBc 1.3.6.1.4.1.397.4.3.1.60
Bc(Burst Commit) - the committed burst that the MegaPAC will allow to be transmitted on this DLCI; the units are 80bits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32767  

chanParamDlciBe 1.3.6.1.4.1.397.4.3.1.61
Be(Burst Excess) is the excess above the Bc that will be transmitted to the line by the MegaPAC in any given Tc. The units are 80bits.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..32767  

chanParamDlciDe 1.3.6.1.4.1.397.4.3.1.62
DE(Discard Eligibility) when set will indicate that in a congested situation this frame should be discarded first.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), all(129)  

chanParamDlciProtocol 1.3.6.1.4.1.397.4.3.1.63
Specifies header in RFC 1480/1490 connections
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), ip(2), ipx(4), iso(8), fragment(16), sna(32)  

chanParamDlciDsap 1.3.6.1.4.1.397.4.3.1.64
Used in RFC 1490 SNA connections - each SAP identifies a specific PU, hence by using different SAPs, multiple PUs can be multiplexed on the same Frame Relay PVC
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..254  

chanParamDlciSsap 1.3.6.1.4.1.397.4.3.1.65
Used in RFC 1490 SNA connections - each SAP identifies a specific PU, hence by using different SAPs, multiple PUs can be multiplexed on the same Frame Relay PVC
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..254  

chanParamDlciPutype 1.3.6.1.4.1.397.4.3.1.66
Used in RFC 1490 SNA connections - specifies type 2.0 or 2.1
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

x25FileSize 1.3.6.1.4.1.397.5.1
X25 file size. The number of entries configured into the X25 file.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

x25Table 1.3.6.1.4.1.397.5.2
A table of X.25 routing entries
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    X25Entry

x25Entry 1.3.6.1.4.1.397.5.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  X25Entry  

x25Index 1.3.6.1.4.1.397.5.2.1.1
Index. The index to an individual X.25 entry
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

x25Name 1.3.6.1.4.1.397.5.2.1.2
Name. A 4 character name which is used to match on the 'NAME' parameter of the channel on which a call will be routed over the X.25 network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4)  

x25AddressGroup 1.3.6.1.4.1.397.5.2.1.3
Address Group. An integer used to partition the X.25 routing tables. Any match on a channel name will only take effect if the channel 'AddressGroup' parameter is set to the same value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

x25Address 1.3.6.1.4.1.397.5.2.1.4
Address. The numeric address which is used to match on the incoming X.25 address in a call request packet.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

x25UserData 1.3.6.1.4.1.397.5.2.1.5
User Data A text field in which Call User Data or Facilities may be placed. The user data will be inserted into call request packets generated by the MegaPAC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..30)  

nameFileSize 1.3.6.1.4.1.397.6.1
Name File Size. The number of entries configured into the NAME file.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

nameTable 1.3.6.1.4.1.397.6.2
A table of 'Name' entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NameEntry

nameEntry 1.3.6.1.4.1.397.6.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NameEntry  

nameIndex 1.3.6.1.4.1.397.6.2.1.1
Index. The index into the name table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

nameName 1.3.6.1.4.1.397.6.2.1.2
Name. A string of up to 8 characters in length which is typed in by the network user in order to establish a connection to a specific resource.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

nameDRCMask 1.3.6.1.4.1.397.6.2.1.3
DRC Mask. The four character resource (channel) name to which the call will be directed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4)  

nameCallPriority 1.3.6.1.4.1.397.6.2.1.4
Call Priority. The internal call priority which will be assigned to the call.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

nameBilling 1.3.6.1.4.1.397.6.2.1.5
Billing If enabled, statistics relating to the call will be sent to the billing file.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(2), disabled(1)  

nameOptions 1.3.6.1.4.1.397.6.2.1.6
Options Enables the appropriate terminal emulation options.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), iso(2), pap(17), ppp(33), pap-ppp(59), prof(5), icl7661(9), teln(65), rev-teln(129)  

passFileSize 1.3.6.1.4.1.397.7.1
Pass File Size. The number of entries configured into the PASSWORD file.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

macFileSize 1.3.6.1.4.1.397.8.1
Mac File Size. The number of entries configured into the MAC file.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

macTable 1.3.6.1.4.1.397.8.2
A table of MAC entries
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MacEntry

macEntry 1.3.6.1.4.1.397.8.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MacEntry  

macIndex 1.3.6.1.4.1.397.8.2.1.1
Index. An index to an individual entry in the MAC table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

macName 1.3.6.1.4.1.397.8.2.1.2
Name. The level 2 controller name to which this entry applies.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4)  

macFunction 1.3.6.1.4.1.397.8.2.1.3
Function. The function field determines what action should be taken if their is a match on this entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nop(1), cad(2), dad(3), cud(4), else(5), fac(6), inse(16386), dele(16387), copy(16388), posn(16389), mark(16390), data(16391), eof(16392), ibeg(32769), iend(32770), obeg(32771), oend(32772), pu(32773), xid(32774), list(32775), mask(32776), sync(32777), tab(32778), rout(32781), nvmt(32782), add(32783), bar(32784)  

macOptions 1.3.6.1.4.1.397.8.2.1.4
Options. Specific actions that may be envoked in conjunction with the function field.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), not(129), trap(33), flag(17), copy(9), jump(32769), expe(16385), iso-1980(8193), bill(4097), talk(2049), thru(5), cad(3), y13(65), iso(2), tcal(1025), rej(513), tlat(257), iso-expe(16386), iso-y13(66)  

macSelector 1.3.6.1.4.1.397.8.2.1.5
Selector. This field can contain a string of between 0 and 32 Hexadecimal characters, that must be matched by the Function DAD, CAD, CUD or FAC.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

macGenerator 1.3.6.1.4.1.397.8.2.1.6
Generator. This field can contain a string of between 0 and 32 Hexadecimal characters, and can have different purposes depending on the Function or Options fields.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

ilanFileSize 1.3.6.1.4.1.397.9.1
Ilan File Size. The number of entries configured into the ILAN file.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ilanTable 1.3.6.1.4.1.397.9.2
A table of ILAN entries
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IlanEntry

ilanEntry 1.3.6.1.4.1.397.9.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  IlanEntry  

ilanIndex 1.3.6.1.4.1.397.9.2.1.1
Index. An index to an individual entry in the ILAN table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ilanName 1.3.6.1.4.1.397.9.2.1.2
Name. The Resource which this entry applies to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4)  

ilanOptions 1.3.6.1.4.1.397.9.2.1.3
Options ISO Allows transport calls to be set up on the outgoing channel. EXPE Allows expedited data to be sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), y13(17), talk(9), dbit(5), iso(2), iso-expe(4), iso-y13(18)  

ilanEthernetAddress 1.3.6.1.4.1.397.9.2.1.4
Ethernet Address. The destination MAC address of the named host.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(12)  

ilanTSAP 1.3.6.1.4.1.397.9.2.1.5
TSAP. The Transport Service Access Point required on the destination Host.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

elogFileSize 1.3.6.1.4.1.397.10.1
Elog File Size. The size of the error log file.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

elogTable 1.3.6.1.4.1.397.10.2
A table of Error Log entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ElogEntry

elogEntry 1.3.6.1.4.1.397.10.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ElogEntry  

elogIndex 1.3.6.1.4.1.397.10.2.1.1
Index. The index to an Error Log entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

elogRecord 1.3.6.1.4.1.397.10.2.1.2
Record. The Error Log entry in ascii format.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(128)  

errorLogReport 0
Enterprise Specific trap for MegaPAC. The Error Log entry in ascii format
TRAP-TYPE    

sysRestart 1
Enterprise Specific trap for MegaPAC System restart.
TRAP-TYPE    

configChange 32
Enterprise Specific trap for MegaPAC Configuration Change.
TRAP-TYPE    

vcpConnect 33
Enterprise Specific trap for MegaPAC VCP Connect.
TRAP-TYPE    

vcpDisconnect 34
Enterprise Specific trap for MegaPAC VCP Disconnect.
TRAP-TYPE    

billThreshReached 35
Enterprise Specific trap for MegaPAC- threshold reached for No. of BILLING records outstanding.
TRAP-TYPE    

linkNoResponse 96
Enterprise Specific trap for MegaPAC Link Not Responding.
TRAP-TYPE    

linkCarrierLoss 97
Enterprise Specific trap for MegaPAC Link Carrier Loss.
TRAP-TYPE    

linkAddressErr 98
Enterprise Specific trap for MegaPAC Link Address Error.
TRAP-TYPE    

frameLessThan2 99
Enterprise Specific trap for MegaPAC Link Frame < 2 BYTES.
TRAP-TYPE    

ifieldTooLarge 100
Enterprise Specific trap for MegaPAC Link I-Field too Large.
TRAP-TYPE    

linkRestart 103
Enterprise Specific trap for MegaPAC Link restart.
TRAP-TYPE    

linkBlocked 104
Enterprise Specific trap for MegaPAC LINK BLOCKED (Flow controlled).
TRAP-TYPE    

linkDisconnect 105
Enterprise Specific trap for MegaPAC Link Disconnected.
TRAP-TYPE    

linkFrmrRecvd 112
Enterprise Specific trap for MegaPAC Link FRMR received.
TRAP-TYPE    

linkDmResponse 113
Enterprise Specific trap for MegaPAC Link DM response.
TRAP-TYPE    

linkBadNr 114
Enterprise Specific trap for MegaPAC Link Bad N(r).
TRAP-TYPE    

linkDown 115
Enterprise Specific trap for MegaPAC Link Down.
TRAP-TYPE    

linkFrmrSent 116
Enterprise Specific trap for MegaPAC Link FRMR sent.
TRAP-TYPE    

crcThreshExceeded 117
Enterprise Specific trap for MegaPAC CRC Threshold Exceeded.
TRAP-TYPE    

linkManRestart 121
Enterprise Specific trap for MegaPAC Link Manual restart.
TRAP-TYPE    

testIndicationResponse 122
Enterprise Specific trap for MegaPAC 'TEST' command Indication/Response.
TRAP-TYPE    

interfaceFailure 123
Enterprise Specific trap for MegaPAC Inteface (e.g. chip) failure.
TRAP-TYPE    

xidComRecvd 124
Enterprise Specific trap for MegaPAC XID command received.
TRAP-TYPE    

bufferOverrun 166
Enterprise Specific trap for MegaPAC Buffer Overrun Error.
TRAP-TYPE    

connectTimeWarn 200
Enterprise Specific trap for MegaPAC Connect Time Warning.
TRAP-TYPE    

isdnNameAssigned 230
Enterprise Specific trap for MegaPAC ISDN/V25 bis Name Assigned.
TRAP-TYPE    

isdnNameDeAassigned 231
Enterprise Specific trap for MegaPAC ISDN/V25 bis Name De-Assigned.
TRAP-TYPE