SHE-MTA-MIB

File: SHE-MTA-MIB.mib (6702 bytes)

Imported modules

AN-MIB IF-MIB SHE-TC-MIB
SNMPv2-CONF SNMPv2-SMI SNMPv2-TC

Imported symbols

she InterfaceIndex SheControlStatusType
OBJECT-GROUP MODULE-COMPLIANCE NOTIFICATION-GROUP
mib-2 Integer32 Unsigned32
OBJECT-TYPE MODULE-IDENTITY NOTIFICATION-TYPE
TEXTUAL-CONVENTION

Defined Types

SheMtaControlRequestType  
The type for mta control commands.
TEXTUAL-CONVENTION    
  INTEGER mtaActivateInward(1), mtaActivateOutward(2), mtaActivateMonitoring(3), mtaActivateForceInward(4), mtaActivateForceOutward(5), mtaDeactivate(6), mtaSetAutoFreeTimer(7)  

SheMtaControlRequestResultType  
The result type for mta control commands.
TEXTUAL-CONVENTION    
  INTEGER mtaNotSupported(8), mtaIUtoSPBnotFound(9), commExecStarted(30), paramFaulty(31), requestBusy(32), setDataFailed(34), aswTimeout(35), commandFailed(36), commandSucceeded(37)  

Defined Values

sheMta 1.3.6.1.4.1.231.7.1.2.1.10
Definition of mta feature control command
MODULE-IDENTITY    

sheMtaControl 1.3.6.1.4.1.231.7.1.2.1.10.1
OBJECT IDENTIFIER    

sheMtaCtrlControlReq 1.3.6.1.4.1.231.7.1.2.1.10.1.1
Controls the metallic test access (MTA) feature (activate or deactivate) at ADSL line interfaces. MTA is provided only for ADSL lines and for one line at a given time. The plugin unit IU must be unlocked. If MTA has been activated for a line the command command mtaActivate implicitly deactivates MTA for that line and activates it on the new line. MTA is service affecting. The command mtaDeactivate terminates MTA. MTA is terminated by the DSLAM autonomously if the IU will be locked or performs a restart.
Status: current Access: read-write
OBJECT-TYPE    
  SheMtaControlRequestType  

sheMtaCtrlControlStatus 1.3.6.1.4.1.231.7.1.2.1.10.1.2
The status of a control request.
Status: current Access: read-only
OBJECT-TYPE    
  SheControlStatusType  

sheMtaCtrlIfIndex 1.3.6.1.4.1.231.7.1.2.1.10.1.3
The interface index of the ADSL central PPTP for which metallic test access shall be activated.
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndex  

sheMtaCtrlIfIndexUnderTest 1.3.6.1.4.1.231.7.1.2.1.10.1.4
If not 0 the interface index of the ADSL central PPTP for which metallic test access is already activated.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

sheMtaAutoFreeTimer 1.3.6.1.4.1.231.7.1.2.1.10.1.5
The time duration of relay switch on.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 50..600  

sheMtaCtrlControlReqResult 1.3.6.1.4.1.231.7.1.2.1.10.1.6
The result of the last user command.
Status: current Access: read-only
OBJECT-TYPE    
  SheMtaControlRequestResultType  

sheMtaCtrlControlTimeStamp 1.3.6.1.4.1.231.7.1.2.1.10.1.7
The time stamp of the last command (end of command).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sheMtaNotifications 1.3.6.1.4.1.231.7.1.2.1.10.2
OBJECT IDENTIFIER    

sheMtaAutoFreeEvent 1.3.6.1.4.1.231.7.1.2.1.10.2.1
End of mta grasping command and free testing subscriber line.
Status: current Access: read-only
NOTIFICATION-TYPE    

sheMtaMibConformance 1.3.6.1.4.1.231.7.1.2.1.10.100
OBJECT IDENTIFIER    

sheMtaMibCompliances 1.3.6.1.4.1.231.7.1.2.1.10.100.1
OBJECT IDENTIFIER    

sheMtaMibCompliance 1.3.6.1.4.1.231.7.1.2.1.10.100.1.1
Description.
Status: current Access: read-only
MODULE-COMPLIANCE    

sheMtaMibGroups 1.3.6.1.4.1.231.7.1.2.1.10.100.2
OBJECT IDENTIFIER    

sheMtaMibControlGroup 1.3.6.1.4.1.231.7.1.2.1.10.100.2.1
Description.
Status: current Access: read-only
OBJECT-GROUP    

sheMtaMibNotificationGroup 1.3.6.1.4.1.231.7.1.2.1.10.100.2.2
Description.
Status: current Access: read-only
NOTIFICATION-GROUP